{"title":"Gas Flow Meters and Controllers","description":"","products":[{"product_id":"inline-flow-meter-master-touch-series-86008700-mp-haz","title":"Inline Flow Meter, Master-Touch Series 8600-8700 MP HAZ","description":"\u003cp\u003eThe 8600-8700 MP Inline Flow Meter Series provides accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" rel=\"nofollow noopener\" target=\"_blank\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaster-Touch Series 8600-8700 MP HAZ, Inline Flow Meter\u003c\/h3\u003e\n\u003cp\u003eMaster-Touch Series products include a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. Then it is controlled by the temperature sensor and bridge circuitry. Furthermore, our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003ch3\u003e8600-8700 Series Inline Flow Meter for Use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazardous Locations\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cp\u003eOur inline flow meter for thermal mass flow measurement includes a flow section that is usually specified to match the userâs flow conduit and is then plumbed directly into the process line. This design also has the sensing elements mounted directly in the flow section for exposure to the process gas. This thermal mass flow inline flow meter is available in sizes from 1\/4\" pipe through 4\" pipe or tube and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as necessary. Pipe sizes more than 4\" typically require insertion style thermal mass flow meters. This integral style inline flow meter has all the electrical components and connections located within one enclosure. Additionally, this enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003ch3\u003eOperating Principle\u003c\/h3\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Furthermore, our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. In addition, our microcontroller operate with smart sensor technology that preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, which causes an increase in the power necessary to maintain a balance between the RTDs. As a result, this increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes. So, the output signal is a true mass flow rate signal.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8600â8700 MP HAZ\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26148 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\" alt=\"Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp\" width=\"750\" height=\"513\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eCertifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApprovals\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Orientation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Housing\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003ePipe Information\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 4\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 6\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e), Multi-Range + Temp Out, Multi-Range + No Temp, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eBACnet\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eProfibus\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e (when applicable): Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMounting Requirements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMNPT Ends\u003c\/li\u003e\n\u003cli\u003eButt End\u003c\/li\u003e\n\u003cli\u003eFlange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSensor Wetted Materials Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eStainless Steel 316L\u003c\/li\u003e\n\u003cli\u003eHastelloy C-276\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364340355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp_60549b24-6b99-4485-bd1a-d8863121157d.png?v=1763385157"},{"product_id":"eldridge-products-valumass-series-500-val-inline-flow-meter","title":"Eldridge Products, ValuMass Series 500 VAL Inline Flow Meter","description":"ValuMass 500 VAL flow meters provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, is undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. Like the ValuMass Series 540, the ValuMass Series 500 inline \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flowmeter\u003c\/a\u003e also uses the proprietary temperature compensation techniques using two RTD (resistance temperature detectors). This design allows the ValuMass Series to deliver accurate measurements day in, day out. If you require reliable mass measurement for an air and gas flow application with an inline installation, the ValuMass Series 500 is an excellent choice that provides great value at a great price. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26153 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch3\u003eThermal Mass Flow Meters\u003c\/h3\u003e ValuMass 500 Series VAL is a rugged, cleanable, thermal mass flow sensor. These flow meters consist of a sensor assembly that utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors rely upon a ceramic substrate that then receives a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged as well as relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. In addition, it is controlled by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003e500 Series Flow Meter from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e\n\u003c\/h3\u003e Our inline style thermal mass flow meters include a flow section that matches the userâs flow conduit and then usually plumbs directly into the process line. Furthermore, the sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2.5\" pipe. The 3.5\" long flow sections have MNPT ends as standard for easy mounting in the process line (options available for pipe sizes over 2.5\"). Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure features a rating for non-hazardous environments. Then the enclosure mounts directly to the inline flow section assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eOperation Principle\u003c\/h3\u003e Thermal mass flow meters from Eldridge Products use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options Eldridge Products - ValuMass 500 Series VAL\u003c\/h3\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003ePipe Information\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 2.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 3.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus RTU\u003c\/a\u003e), \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e: Standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e: 0-5, 0-10\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMounting Requirements\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eMNPT Ends\u003c\/li\u003e \u003cli\u003eButt End\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Wetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eStainless Steel 316L\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364405891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-ValuMass-Inline-Thermal-Mass-Flow-Meter-500-VAL-EPI-Process-Solutions-Corp.png?v=1763385160"},{"product_id":"el-flow-select-series-mass-flow-meters-and-controllers","title":"EL-FLOW Select Series, Mass Flow Meters and Controllers","description":"\u003cul\u003e \u003cli\u003ehigh accuracy (standard 0.5% Rd plus 0.1% FS)\u003c\/li\u003e \u003cli\u003erangeability in digital mode up to 1:187.5\u003c\/li\u003e \u003cli\u003efast response (down to 500 msec), excellent repeatability\u003c\/li\u003e \u003cli\u003eoptional multi-gas \/ multi-range functionality: freely programmable ranges and gas types\u003c\/li\u003e \u003cli\u003epressure ratings 64 up to 400 bar (Multi-Gas \/ Multi-Range functionality up to 10 bar)\u003c\/li\u003e \u003cli\u003eanalog I\/O-signals, RS232-connection; optional on-board fieldbus interface\u003c\/li\u003e \u003cli\u003eelectrochemical polishing of all surfaces\u003c\/li\u003e \u003cli\u003ecompact, modular construction\u003c\/li\u003e \u003cli\u003emetal sealed and\/or down-ported versions available\u003c\/li\u003e \u003cli\u003ebest in class mean-time-between-failure (MTBF) data based on the IEC 61508 standard\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=G62ma2IFh9o \u003ch3\u003eDigital = Standard on the EL-FLOW\u003c\/h3\u003e All models of the EL-FLOW Select series are equipped with a digital pc-board, featuring self-diagnostics, alarm and counter functions, digital communication (RS232) and remotely adjustable control settings. These digital instruments from Bronkhorst offer great flexibility thanks to the âmultibusâ concept, whereby the instruments can be equipped with an on-board interface with \u003ca href=\"https:\/\/www.can-cia.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCANopen\u003c\/a\u003e, DeviceNet, EtherCAT, \u003ca href=\"http:\/\/profibus.com\" target=\"_blank\" rel=\"noopener\"\u003ePROFIBUS DP, PROFINET\u003c\/a\u003e, \u003ca href=\"http:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus RTU\u003c\/a\u003e, ASCII or TCP\/IP, EtherNet\/IP, POWERLINK, or FLOW-BUS protocol. \u003ca href=\"https:\/\/psctexas.com\/new-field-bus-options\/\"\u003eMore information about digital âmultibusâ communication\u003c\/a\u003e. \u003ch3\u003eOptional Multi Gas \/ Multi Range\u003c\/h3\u003e EL-FLOW Select instruments can be offered with optional Multi Gas \/ Multi Range (MG\/MR) functionality. This option offers greater flexibility for user selection of both flow ranges and gas types, maintaining high accuracy and turndown range for measurement and control. Thanks hereto, users of these instruments can rescale their instruments on site, saving time (and money) for mounting and dismounting. For the convenience of the user, Bronkhorst has developed an easy-to-use software tool called âFlowTuneâ for changing the configuration of EL-FLOW Select instruments with activated Multi Fluid \/ Multi Range option (available up to 10 bar operating pressure; to be specified at the moment of ordering). https:\/\/www.youtube.com\/watch?v=slmMaVjjH-U \u003ch3\u003eApplications for the EL-FLOW\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eanalytical \/ environmental equipment\u003c\/li\u003e \u003cli\u003egas flow monitoring in \u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003efood\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical, and petrochemical industries\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003egas consumption measurement in gas distribution systems for internal accounting purposes\u003c\/li\u003e \u003cli\u003edetection of gas leakage through objects\u003c\/li\u003e \u003cli\u003esemiconductor manufacturing\u003c\/li\u003e \u003cli\u003esurface treatment installations\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2019\/06\/Water-repellent-fabrics-and-textiles.pdf\" target=\"_blank\" rel=\"noopener\"\u003econtrolled supply of polymer precursors to make fabric water-repellent\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eice cream aeration\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ediamond deposition HFCVD\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2019\/06\/Plasma-Spraying.pdf\" target=\"_blank\" rel=\"noopener\"\u003eplasma spraying\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\"\u003egas mixing setup to calibrate oxygen sensor for monitoring beer quality\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003euse of flow control in photovoltaic (PV) solar cell production\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878365585539,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EL-FLOW-Select-Mass-Flow-Meters-Controllers-for-Gas.jpg?v=1763385201"},{"product_id":"el-flow-prestige-series-mass-flow-meters-and-controllers","title":"EL-FLOW Prestige Series, Mass Flow Meters and Controllers","description":"\u003cul\u003e\n\u003cli\u003ehigh accuracy (standard 0.5% Rd plus 0.1% FS)\u003c\/li\u003e\n\u003cli\u003erangeability in digital mode up to 1:150\u003c\/li\u003e\n\u003cli\u003eextremely fast and dynamic response\u003c\/li\u003e\n\u003cli\u003emulti-gas \/ multi-range functionality (100 selectable gases; scalable between 40%-120% or ordered capacity (FS value)\u003c\/li\u003e\n\u003cli\u003epressure ratings 10 \/ 64 \/ 100 bar\u003c\/li\u003e\n\u003cli\u003eanalog I\/O-signals, RS232-connection; optional on-board fieldbus interface\u003c\/li\u003e\n\u003cli\u003egreat variety of customized I\/O options\u003c\/li\u003e\n\u003cli\u003euser configurable control characteristics\u003c\/li\u003e\n\u003cli\u003erobust metal housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eThermal Mass Flow Meter with Fast Response to Improve Performance\u003c\/h2\u003e\n\u003cp\u003eThe control performance of EL-FLOW Prestige Thermal Mass Flow Controllers is factory adjusted to swiftly respond to setpoint changes, without overshoot. Moreover, this \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Meters and Controllers\"\u003elow flow\u003c\/a\u003e meter\/controller are highly resistant to mechanical shocks and pressure fluctuations, which may be caused by other devices consuming gas from the same source. As an option the MFCs can be tuned for extra fast response (settling times t98% down to 500 msec) or extra smooth control, depending on the requirements of the user’s process. The dynamic behaviour can also be tuned on site easily, by adjusting the controller speed settings via FlowTune, or by using our software tool FlowPlot. This free tool can also be used for device diagnostics or alarm and counter settings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSelect the I\/O Options of Your Preference\u003c\/h2\u003e\n\u003cp\u003eNumerous input\/output options can be offered through the programmable sub-D 9-pin connector. In addition to the various analog signal options and the standard RS232 communication, there are such options as RS485 communication, digital frequency\/pulse output, alarm output\/reset, valve purge\/close and analog valve output. Furthermore Bronkhorst offers various integrated fieldbus options: CANopen, DeviceNet, PROFIBUS DP, PROFINET, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus RTU\/ASCII\u003c\/a\u003e, EtherCAT and FLOW-BUS. The latter is an RS485 based fieldbus, specifically designed by Bronkhorst for their mass flow metering and control solutions. For the convenience of customers working with LabVIEW (graphical software by National Instruments) Bronkhorst provides a certified plug \u0026amp; play instrument driver for instruments with FLOW-BUS interface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAnalytical\/environmental equipment\u003c\/li\u003e\n\u003cli\u003eGas flow monitoring in food, chemical and petrochemical industries\u003c\/li\u003e\n\u003cli\u003eGas consumption measurement in gas distribution systems for internal accounting purposes\u003c\/li\u003e\n\u003cli\u003eDetection of gas leakage through objects\u003c\/li\u003e\n\u003cli\u003eSemiconductor manufacturing\u003c\/li\u003e\n\u003cli\u003eSurface treatment installations\u003c\/li\u003e\n\u003cli\u003eSimulation of exhaust gas to test lambda probe (sensor)\u003c\/li\u003e\n\u003cli\u003eWater splitting for hydrogen production\u003c\/li\u003e\n\u003cli\u003eCalibration setup for mass flow devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371057795,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Elflow.jpg?v=1763385334"},{"product_id":"el-flow-metal-sealed-series-mass-flow-meters-and-controllers","title":"EL-FLOW Metal Sealed Series, Mass Flow Meters and Controllers","description":"\u003cimg class=\"alignright wp-image-8594\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/EL-FLOW-Metal-Sealed-Mass-Flow-Meters-Controllers-for-Gas-300x225.jpg\" alt=\"Bronkhorst-EL-FLow-Metal-Sealed-Mass-Flow-meters\" width=\"500\" height=\"374\"\u003e \u003cul\u003e \u003cli\u003eresealable metal-to-metal outer seal construction (no rings)\u003c\/li\u003e \u003cli\u003eelectropolished wetted parts\u003c\/li\u003e \u003cli\u003ecleanroom assembled\u003c\/li\u003e \u003cli\u003eanalog and digital I\/O, with optionally integrated interface to \u003ca href=\"https:\/\/www.can-cia.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCANopen\u003c\/a\u003e, DeviceNet, EtherCAT, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003ePROFIBUS DP, PROFINET\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus RTU\u003c\/a\u003e, ASCII or TCP\/IP, EtherNet\/IP, POWERLINK, or FLOW-BUS\u003c\/li\u003e \u003cli\u003ehigh accuracy and repeatability\u003c\/li\u003e \u003cli\u003estable control, even at varying process volumes\u003c\/li\u003e \u003c\/ul\u003e EL-FLOW Metal Sealed Series gas mass flow meters and controllers, from \u003ca href=\"https:\/\/psctexas.com\/brand\/bronkhorst\/\"\u003eBronkhorst\u003c\/a\u003e, are characterized by their unique, patented metal-to-metal seal construction with excellent resealing capability. Furthermore they distinguish themselves by a high surface quality and are therefore especially suitable for meeting the semiconductor and solar industry requirements as well as other high purity gas applications. The base blocks of the Mass Flow Meters and Controllers have 1\/4\" face seal male (VCR) connections. Today's instruments are equipped with a digital pc-board, offering high-accuracy, excellent temperature stability and fast response (settling time t98 down to 500 msec). The latest EL-FLOW design features Multi Gas \/ Multi Range functionality, providing (OEM) customers with optimal flexibility and process efficiency. For the convenience of the customer Bronkhorst provides easy to use configuration software. \u003cul\u003e \u003cli\u003eLowest range 0.12 to 6 ml\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e \u003cli\u003eHighest range 1 to 50 l\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eEL-FLOW Metal Sealed Series, Mass Flow Meters and Controllers Model Line-Up\u003c\/h3\u003e \u003ch5 style=\"text-align: left;\"\u003eMass Flow Meters (MFM)\u003c\/h5\u003e \u003cem\u003eranges based on N2\u003c\/em\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003emin. flow\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003emax. flow\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-111CM\u003c\/td\u003e \u003ctd\u003e0.1-5 sccm\u003c\/td\u003e \u003ctd\u003e1-50 slm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5 style=\"text-align: left;\"\u003eMass Flow Controllers (MFC)\u003c\/h5\u003e \u003cem\u003eranges based on N\u003csmall\u003e2\u003c\/small\u003e\u003c\/em\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003emin. flow\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003emax. flow\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-201CM*\u003c\/td\u003e \u003ctd\u003e0.12-6 sccm\u003c\/td\u003e \u003ctd\u003e1-50 slm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e* Kv-max = 6,6 x 10-2\u003c\/em\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371090563,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Elflow_select.jpg?v=1763385335"},{"product_id":"in-flow-series-thermal-mass-flow-meters-and-controllers","title":"IN-FLOW Series, Thermal Mass Flow Meters and Controllers","description":"\u003cul\u003e \u003cli\u003eHigh accuracy (standard 0.5% of Rd plus 0.1% of FS)\u003c\/li\u003e \u003cli\u003eRangeability in digital mode up to 187.5 : 1\u003c\/li\u003e \u003cli\u003eOptional Multi-Gas \/ Multi-Range functionality: freely programmable ranges and gas types\u003c\/li\u003e \u003cli\u003ePressure rating 64 up to 700 bar (Multi-Gas \/ Multi-Range functionality up to 10 bar)\u003c\/li\u003e \u003cli\u003eRugged, weatherproof housing (IP65, dust and waterproof)\u003c\/li\u003e \u003cli\u003eOption: ATEX approval for Cat. 3, Zone 2\u003c\/li\u003e \u003cli\u003eOption: FM approval Class I, Div. 2 (Groups A, B, C, D; T4)\u003c\/li\u003e \u003cli\u003eOption: KCs certificate (Protection Ex nA IIC T4)\u003c\/li\u003e \u003cli\u003eAnalog or digital communication (RS232 or fieldbus interface)\u003c\/li\u003e \u003cli\u003eHigh flow versions available (up to 11000 m\u003csup\u003e3\u003c\/sup\u003e\u003csmall\u003en\u003c\/small\u003e\/h)\u003c\/li\u003e \u003cli\u003eBest in class mean-time-between-failure (MTBF) data based on the IEC 61508 standard\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=h8WZg907oSE \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eProcess gas measurement in \u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003efood industry\u003c\/a\u003e, chemical and petrochemical industries, in fermentation installations and in biotechnology\u003c\/li\u003e \u003cli\u003eSample gas measurement in environmental analysis\u003c\/li\u003e \u003cli\u003eGas consumption measurement for internal accounting\u003c\/li\u003e \u003cli\u003eSystems for environmental air sampling\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-role-of-flow-control-in-hydrogen-production\/\"\u003eHydrogen techniques\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eBurner control\u003c\/li\u003e \u003cli\u003eFlow control in formic acid production\u003c\/li\u003e \u003cli\u003eControlled supply of oxygen for iron removal in drinking water production\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eDigital Features and Fieldbus Interfaces\u003c\/h4\u003e All models of the IN-FLOW series are equipped with a digital pc-board, featuring self-diagnostics, alarm and counter functions, digital communication and remotely adjustable control settings. These digital instruments from Bronkhorst offer great flexibility their instruments with an on-board interface with CANopenÂ®, DeviceNetâ¢, EtherCATÂ®, PROFIBUS DP, PROFINET, Modbus RTU, ASCII or TCP\/IP, EtherNet\/IP, POWERLINK, or FLOW-BUS protocol. \u003ca title=\"New Field Bus Options\" href=\"https:\/\/psctexas.com\/new-field-bus-options\/\"\u003eMore information about digital \"multibus\" communication.\u003c\/a\u003e \u003ch4\u003eApprovals for Hazardous Locations\u003c\/h4\u003e IN-FLOW Series mass flow meters and controllers can be configured for use in explosive environments with FM Class I Division 2 approval, up to a pressure rating of 400 bar (5800 psi). \u003ch4\u003eMulti Gas \/ Multi Range Functionality\u003c\/h4\u003e IN-FLOW instruments with Multi Gas \/ Multi Range (MG\/MR) functionality offer greater flexibility for user selection of both flow ranges and gas types, maintaining high accuracy and turndown range for measurement and control. Thanks to this feature, mass flow meters \/ controllers can be rescaled on site, saving time (and money) for mounting and dismounting. For the convenience of the user, Bronkhorst has developed an easy-to-use software tool called \"FlowTune\" for changing the configuration of instruments with activated Multi Gas \/ Multi Range option (available up to 10 bar operating pressure; to be specified at the moment of ordering). \u003ch4\u003eIN-FLOW Series Thermal Mass Flow Meters and Controllers Model Line-Up\u003c\/h4\u003e \u003ch5\u003eMass Flow Meters\u003c\/h5\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2Â \u003c\/sub\u003eequivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 200 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 400 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 700 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eF-110CIÂ |Â 0.7 ... 9Â ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-120MIÂ |Â 10 ... 15 ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-130MIÂ |Â 10 ... 15 ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-111BIÂ Â | Â 0.008 ... 25 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-121MIÂ | Â 0.015 ... 20 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-131MIÂ | Â 0.015 ... 20 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-141MIÂ | Â 0.015 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-111AIÂ |Â 20 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-121MIÂ | Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-131MIÂ | Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-141MIÂ | Â 0.015 ... 100 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-112AIÂ |Â 40 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-122MIÂ |Â 15 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-132MIÂ |Â 15 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-142MIÂ |Â 100 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-113AIÂ |Â 200 ... 1670 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-123MIÂ Â |Â 200 ... 1250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-133MIÂ |Â 200 ... 1250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-143MIÂ |Â 250 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eMass Flow Controllers\u003c\/h4\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2Â \u003c\/sub\u003eequivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 64 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 200 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 400 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 700 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eF-200CIÂ |Â Â 0.7 ... 9Â ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-210CIÂ | Â 0.7 ... 9Â ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-230MIÂ |Â 10 ... 500 ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-240MIÂ |Â 10... 500 ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-201CIÂ | Â 0.008 ... 25 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-211CIÂ | Â 0.008 ... 25 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd colspan=\"1\"\u003eF-221MIÂ Â | Â 0.015 ... 20 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-231MIÂ |Â 0.5 ... 10 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-241MIÂ |Â 0.5 ... 10 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-201AIÂ |Â 20 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-211AIÂ |Â 20 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd colspan=\"1\"\u003eF-221MIÂ Â | Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-231MIÂ |Â 0.5 ... 10 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-241MIÂ |Â 0.5 ... 10 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-202AIÂ |Â 40 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-212AIÂ |Â 40 ... 250 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd colspan=\"1\"\u003e\u003c\/td\u003e \u003ctd\u003eF-232MIÂ |Â 10 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-242MIÂ |Â 10 ... 100 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-203AIÂ |Â 200 ... 1670 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-213AIÂ |Â 200 ... 1670 l\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371123331,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/IN-FLOW-Bronkhorst-HazLoc-Low-Flows-High-Flow-instrumentation-process-solutions-corp.png?v=1763385337"},{"product_id":"in-flow-series-high-flow-mass-flow-meters-and-controllers","title":"IN-FLOW Series, High-Flow Mass Flow Meters and Controllers","description":"\u003cul\u003e \u003cli\u003eHigh accuracy (standard 1% of FS)\u003c\/li\u003e \u003cli\u003eRugged, weatherproof housing (\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65, dust and waterproof\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003eOption: ATEX approval for Zone 2\u003c\/li\u003e \u003cli\u003eOption: FM approval Class I, Div. 2 (Groups A, B, C, D; T4)\u003c\/li\u003e \u003cli\u003eOption: KCs certificate (Protection Ex nA IIC T4)\u003c\/li\u003e \u003cli\u003eNo moving parts\u003c\/li\u003e \u003cli\u003eAnalog or digital communication (RS232 or fieldbus interface)\u003c\/li\u003e \u003cli\u003eBest in class mean-time-between-failure (MTBF) data based on the IEC 61508 standard\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=h8WZg907oSE \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eProcess gas measurement and control in \u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003efood industry\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical and petrochemical industries\u003c\/a\u003e, in \u003ca href=\"https:\/\/psctexas.com\/gas-flow-controllers-for-bacterial-growth-in-bioreactors\/\"\u003efermentation installations\u003c\/a\u003e and in \u003ca href=\"https:\/\/psctexas.com\/benchtop-bioreactors-and-gas-flow-control\/\"\u003ebiotechnology\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eGas consumption measurement for internal accounting\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-role-of-flow-control-in-hydrogen-production\/\"\u003eHydrogen techniques\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApprovals and Communication\u003c\/h4\u003e IN-FLOW Series mass flow meters and controllers can be configured for use in explosive environments with FM Class I Division 2 approval. Their digital pc-board offers counter and alarm functions as a standard feature, as well as the option to integrate an on-board interface board for CANopen, DeviceNet, EtherCAT, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"noopener\"\u003ePROFIBUS DP, PROFINET\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus RTU\u003c\/a\u003e, ASCII or TCP\/IP, EtherNet\/IP, POWERLINK, or FLOW-BUS communication. \u003ch4\u003eMass Flow Controllers for High Gas Flow Rates\u003c\/h4\u003e IN-FLOW high-flow thermal mass flow meter and controller models F-206AI and F-206BI are compact Mass Flow Controllers with integrated, normally closed control valves with up to Kv-values of 6.0 and flow rates up to approximately 375 m\u003csup\u003e3\u003c\/sup\u003e\u003csmall\u003en\u003c\/small\u003e\/h N\u003csmall\u003e2\u003c\/small\u003e -equivalent. \u003ch4\u003eIN-FLOW Series High-Flow Thermal Mass Flow Meters and Controllers Model Line-Up\u003c\/h4\u003e \u003ch5\u003eMass Flow Meters\u003c\/h5\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 40 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 200 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 400 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eF-106AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-116AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-126AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-136AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106BIÂ Â |Â 50 ...Â 500Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-116BIÂ Â |Â 50 ...Â 375Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-126BIÂ Â |Â Â 50 ...Â 375Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-136BIÂ Â |Â 50 ...Â 375Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106CIÂ Â |Â 100 ...Â 1000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106DIÂ Â |Â 180 ...Â 1800Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106EIÂ Â |Â 400 ...Â 4000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106FIÂ Â |Â 700 ...Â 7000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106GIÂ Â |Â 1100 ...Â 11000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-117AIÂ Â |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107BIÂ Â |Â 50 ...Â 500Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-117BIÂ Â |Â 50 ...Â 500Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107CIÂ Â |Â 100 ...Â 1000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-117CIÂ Â |Â 100 ...Â 1000Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107DIÂ Â |Â 180 ...Â 1800Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-117DIÂ Â |Â 180 ...Â 1800Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eMass Flow Controllers\u003c\/h5\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 64 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eF-206AIÂ |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-216AIÂ |Â 20 ...Â 200Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-206BIÂ |Â 50 ...Â 375Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-216BIÂ |Â 50 ...Â 375Â m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371156099,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Inflow2.jpg?v=1763385338"},{"product_id":"mass-stream-series-thermal-mass-flow-meters-and-controllers","title":"MASS-STREAM Series, Thermal Mass Flow Meters and Controllers","description":"\u003cp\u003eThe MASS-STREAM series are thermal, inline flow meters for gases. If you are looking for an instrument to measure \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\" title=\"Gas Flow Meters and Controllers\"\u003egas flow\u003c\/a\u003e which is less sensitive to humidity and dirt, you should consider using the MASS-STREAM series. This series, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/bronkhorst\" title=\"Bronkhorst Low Flow Instrumentation\"\u003eBronkhorst\u003c\/a\u003e, is a perfect fit for pilot plants and production sites in industrial environment, such as burner applications, industrial furnace processes, biogas installations, aeration processes in the food \u0026amp; beverage industry and nitrogen purging in the semiconductor market.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVirtually insensitive to moisture or particulates\u003c\/li\u003e\n\u003cli\u003eLow pressure drop\u003c\/li\u003e\n\u003cli\u003eStandard accuracy: ± 1.0% RD plus ± 0.5% FS (at calibration conditions)\u003c\/li\u003e\n\u003cli\u003eRangeability up to 1 : 100\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof housing (IP65, dust and waterproof)\u003c\/li\u003e\n\u003cli\u003eAnalog or digital communication (RS232 or fieldbus interface)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProcess gas measurement in food industry, chemical and petrochemical industries, in fermentation installations and in biotechnology\u003c\/li\u003e\n\u003cli\u003eSample gas measurement in environmental analysis\u003c\/li\u003e\n\u003cli\u003eGas consumption measurement for internal accounting\u003c\/li\u003e\n\u003cli\u003eMethane production in anaerobic digesters\u003c\/li\u003e\n\u003cli\u003eBurners \/ furnaces\u003c\/li\u003e\n\u003cli\u003eSurface treatment\u003c\/li\u003e\n\u003cli\u003eAeration \/ gas purging\u003c\/li\u003e\n\u003cli\u003eTest benches\u003c\/li\u003e\n\u003cli\u003eOxygen supply in beer brewing process\u003c\/li\u003e\n\u003cli\u003eCalibration of air samplers\u003c\/li\u003e\n\u003cli\u003e3D printing of metal products\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eAeration of liquids or substances\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371188867,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Mass-Stream.jpg?v=1763385340"},{"product_id":"low-p-flow-series-low-pressure-drop-mass-flow-meters-and-controllers","title":"LOW-ΔP-FLOW Series, Low Pressure Drop Mass Flow Meters and Controllers","description":"\u003cul\u003e\n \t\u003cli\u003eVery low pressure drop\u003c\/li\u003e\n \t\u003cli\u003eLonger lifetime when used on corrosive gases\u003c\/li\u003e\n \t\u003cli\u003eLower contamination risk\u003c\/li\u003e\n \t\u003cli\u003eEasy to clean\u003c\/li\u003e\n \t\u003cli\u003eElectro-polished stainless steel wetted parts\nAvailable with control valve to constitute a complete, compact control loop\u003c\/li\u003e\n \t\u003cli\u003eAvailable with industrial (IP65 weatherproof) housing with optional ATEX Zone 2 Cat. 3 or FM Class I, Div. 2 approval.\u003c\/li\u003e\n \t\u003cli\u003eBest in class mean-time-between-failure (MTBF) data based on the IEC 61508 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003eEnvironmental air sampling at atmospheric conditions\u003c\/li\u003e\n \t\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-control-for-leakage-test-of-air-ducts\/\"\u003eLeak rate tests\u003c\/a\u003e\u003c\/li\u003e\n \t\u003cli\u003eGas consumption measurement, for example of natural gas, in low pressure gas distribution systems\u003c\/li\u003e\n \t\u003cli\u003eBurner control\u003c\/li\u003e\n \t\u003cli\u003eDiamond deposition HFCVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\"Multibus\" Digital Mass Flow Meters and Controllers\u003c\/h4\u003e\nLOW-ΔP-FLOW Low Pressure Drop Series mass flow meters and controllers have a flexible multibus concept, which allows the instruments to be equipped with on-board interface board. Available for use with \u003ca href=\"https:\/\/www.can-cia.org\/canopen\/\" target=\"_blank\" rel=\"noopener\"\u003eCANopen\u003c\/a\u003e, DeviceNet, EtherCAT, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"noopener\"\u003ePROFIBUS DP, PROFINET\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus RTU\u003c\/a\u003e, ASCII or TCP\/IP, EtherNet\/IP, POWERLINK, or \u003ca href=\"https:\/\/psctexas.com\/using-flowbus-with-flowsuite-fieldbus-communication-protocol\/\"\u003eFLOW-BUS protocol\u003c\/a\u003e. \u003ca title=\"New Field Bus Options\" href=\"https:\/\/psctexas.com\/new-field-bus-options\/\"\u003eLearn more information about digital multibus communication.\u003c\/a\u003e\n\u003ch4\u003eLOW-ΔP-FLOW Series Low Pressure Drop Mass Flow Meters and Controllers Model Line-Up\u003c\/h4\u003e\n\u003ch5\u003eMass Flow Meters\u003c\/h5\u003e\n\u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating and Ingress Protection rating\u003c\/em\u003e\u003c\/small\u003e\n\u003ctable class=\"table\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"thead\"\u003e\n\u003cth width=\"50%\"\u003ePN 10 bar - IP40\u003c\/th\u003e\n\u003cth width=\"50%\"\u003ePN 10 bar - IP65\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-100D   |  10 ... 20 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-100DI  |  10 ... 20 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-101D   |  0.021 ... 2.1 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-101DI  |  0.021 ... 2,1 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-101E   |  1.4 ... 12 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-101EI  |  1.4 ... 12 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-102D   |  14 ... 25 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-102DI  |  14 ... 25 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-102E  |  8.5 ... 50 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-102EI  |  8.5 ... 50 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-103D   |  40 ... 150 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-103DI  |  40 ... 150 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-103E   |  45 ... 200 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-103EI  |  45 ... 200 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eF-106Z   |  10 ... 1000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eF-107Z   |  10 ... 1000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eMass Flow Controllers\u003c\/h5\u003e\n\u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating and Ingress Protection rating\u003c\/em\u003e\u003c\/small\u003e\n\u003ctable class=\"table\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"thead\"\u003e\n\u003cth width=\"50%\"\u003ePN 10 bar - IP40\u003c\/th\u003e\n\u003cth width=\"50%\"\u003ePN 10 bar - IP65\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-200DV  |  10 ... 20 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-200DI   |  10 ...20 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-201DV  |  0.021 ... 2.1 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-201DI   |  0.021 ... 2.1 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-201EV  |  1.4 ... 12 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-201EI   |  1.4 ... 12 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-202DV  |  14 ... 25 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-202DI   |  14 ... 25 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-202EV  |  8.5 ... 50 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003eF-202EI   |  8.5... 50 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-201DS  |  0.021 ... 2.1 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-201ES  |  1.4 ... 12 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371221635,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/lowflow.jpg?v=1763385341"},{"product_id":"ex-flow-series-explosion-proof-mass-flow-meters-and-controllers","title":"EX-FLOW Series, Explosion Proof Mass Flow Meters and Controllers","description":"\u003cul\u003e \u003cli\u003eATEX approval Cat.2, Zone 1\u003c\/li\u003e \u003cli\u003ePressure ratings up to 400 bar\u003c\/li\u003e \u003cli\u003eRugged, weatherproof housing (\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65, dust, and waterproof\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003eHigh flow versions available (up to 11000 m\u003csup\u003e3\u003c\/sup\u003e\u003csmall\u003en\u003c\/small\u003e\/h)\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003eProcess gas measurement or control in (petro)chemical industries\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/humidification-of-fuel-cells\/\"\u003eFuel cell technology\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eGas distribution systems\u003c\/li\u003e \u003cli\u003eHydrogenation processes\u003c\/li\u003e \u003cli\u003eGas consumption measurement for internal accounting\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-role-of-flow-control-in-hydrogen-production\/\"\u003eHeating or biogas production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eExplosive mixture composition\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eGas Flow Control for Hazardous Areas\u003c\/h4\u003e The EX-FLOW Mass Flow Controller has a control valve with fast and smooth control characteristics. The flow meter and valve should be connected (via separate cables) to a power supply with galvanic isolation \/ preamplifier \/ readout system (located in the safe zone) which contains a controller board to complete the control loop. The control valve receives its input from the controller board and immediately responds to any deviation between the output signal from the flow sensor and the setpoint signal. \u003ch4\u003eBronkhorst Offers Two Types of Coils:\u003c\/h4\u003e \u003cem\u003eStyle \"XB\"\u003c\/em\u003e = intrinsic safe coil; needs safety barrier. protection II 1 G Ex ia IIC T6 protection II 1 D Ex ta IIIC T80Â°C \u003cem\u003eStyle \"XC\" \u003c\/em\u003e= moulded coil; no safety barrier required. protection II 2 G Ex eb IIC T4 protection II 2 D Ex tb IIIC T130Â°C \u003ch4\u003eEX-FLOW Explosion Proof Mass Flow Meters and Controllers Model Line-Up\u003c\/h4\u003e \u003ch5\u003eMass Flow Meters\u003c\/h5\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\" width=\"100%\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 40 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 200 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 400 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-110CXÂ |Â 7.5 ... 9.5 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-120MXÂ |Â 7.5 ... 9.5 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-130MXÂ |Â 7.5 ... 9.5 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-111BXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-121MXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-131MXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-111AXÂ | 5 ... 100 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-121MXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-131MXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-112AXÂ |Â 40 ... 250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-122MXÂ |Â 15 ... 250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-132MXÂ |Â 15 ... 250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eF-113AXÂ |Â 200 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-123MXÂ |Â 200 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-133MXÂ |Â 200 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106AXÂ |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-116AXÂ |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-126AXÂ Â |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-136AXÂ Â |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106BXÂ |Â 50 ... 500 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-116BXÂ |Â 50 ... 375 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-126BXÂ |Â 50 ... 375 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106CXÂ |Â 100 ... 1000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106DXÂ |Â 180 ... 1800 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106EXÂ |Â 400 ... 4000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106FXÂ |Â 700 ... 7000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-106GXÂ |Â 1100 ... 11000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107AXÂ |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107BXÂ |Â 50 ... 500 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107CXÂ |Â 100 ... 1000 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-107DXÂ |Â 180 ... 1800 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003e\u003cstrong\u003eMass Flow Controllers\u003c\/strong\u003e\u003c\/h5\u003e \u003csmall\u003e\u003cem\u003eFull Scale capacities (N\u003csub\u003e2\u003c\/sub\u003e-equivalent) versus pressure rating\u003c\/em\u003e\u003c\/small\u003e \u003ctable class=\"table\" width=\"100%\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"20%\"\u003ePN 64 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 100 bar\u003c\/th\u003e \u003cth width=\"20%\"\u003ePN 400 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eF-200CXÂ |Â 9.5 ... 9.5 ml\u003csub\u003en\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-210CXÂ |Â 9.5 ... 9.5 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-230MXÂ |Â 10 ... 500 ml\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-201CXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-211CXÂ |Â 0.015 ... 20 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-231MXÂ |Â 0.5 ... 10 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-201AXÂ |Â 5 ... 100 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-211AXÂ |Â 5 ... 100 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-231MXÂ |Â 0.5 ... 10 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-202AXÂ |Â 30 ... 250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-212AXÂ |Â 30 ... 250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-232MXÂ |Â 10 ... 100 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-203AXÂ |Â 200 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003eF-213AXÂ |Â 200 ... 1250 l\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-206AXÂ |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-216AXÂ |Â 20 ... 200 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eF-206BXÂ |Â 50 ... 375 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003eF-216BXÂ |Â 50 ... 375 m\u003csup\u003e\u003cspan style=\"font-size: small;\"\u003e3\u003c\/span\u003e\u003c\/sup\u003e\u003csub\u003e\u003cspan style=\"font-size: small;\"\u003en\u003c\/span\u003e\u003c\/sub\u003e\/h\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371254403,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EX-FLOW-Bronkhorst-HazLoc-Flow-Meter-Low-Flows-Hazardous-Areas-Process-Solutions-Corp.png?v=1763385343"},{"product_id":"iqflow-series-compact-flow-meter-and-controller","title":"IQ+FLOW Series, Compact Flow Meter and Controller","description":"\u003cul\u003e \u003cli\u003eCompact assembly ensures space efficiency\u003c\/li\u003e \u003cli\u003eEconomical solution, low cost of ownership\u003c\/li\u003e \u003cli\u003eAnalog or digital communication\u003c\/li\u003e \u003cli\u003eTop-mount modules, easily accessible\u003c\/li\u003e \u003cli\u003ePre-tested âPlug and Playâ manifold assemblies reduce custom testing requirements\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHighly Accurate Control and Performance\u003c\/h3\u003e The IQ+FLOW Series Compact Flow Meter and Controller are sophisticated microprocessor-based instruments offering high accuracy and repeatability. Up to 8 calibration curves can be stored on the instrument, thus eliminatingÂ the need to recalibrate the device for different gases. The PID controller, integrated on the pc-board, ensures \u003ca href=\"https:\/\/psctexas.com\/stable-gas-flow-control-for-analytical-instruments\/\"\u003ehighly stable control\u003c\/a\u003e. And as an option, this allows for the adjustment of the settling time down to 300 msec. This is especially useful for processes that require fast response times. \u003ch3\u003eIQ+FLOW Compact Flow Meter and Controller\u003c\/h3\u003e Previously, \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\/\"\u003econventional mass flow meters and controllers\u003c\/a\u003e have needed a footprint of 1.5 inches, as for instance, specified in the NeSSITM system. Now, and in close co-operation with the Netherlands organization for applied scientific research \u003ca href=\"https:\/\/www.tno.nl\/en\/\" target=\"_blank\" rel=\"noopener\"\u003eTNO\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eBronkhorst\u003c\/a\u003e has developed the IQ+FLOW compact flow meter and controller. Due to the use of micro system technology (MST), Bronkhorst has been able to reduce the footprint dimension to half, at 0.75â. And this creates an ultra compact flow controller for low flow rates from 0.2 to 5,000 ml\u003csmall\u003en\u003c\/small\u003e\/min. \u003ch3\u003eMicrofluidic Device for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003eResearch and Analytical Use\u003c\/a\u003e\n\u003c\/h3\u003e The use of micro fluidic devices for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003eresearch and analytical purposes\u003c\/a\u003e has some important advantages. Firstly, because the internal volumes within the instruments are very small, the analysis will be faster and the amount of reagents and analytes used can be reduced.Â The latter is especially significant for expensive reagents. Furthermore, the physical dimensions are much smaller than those of conventional devices. This enables Life Sciences system integrators to downscale the size, inherently reducing the costs of ownership of their equipment. Also, the availabilityÂ of compact and lightweight instruments could lead to the development of portable systems. \u003ch3\u003eMultichannel Compact Flow Meter\u003c\/h3\u003e Thanks to the modular concept of the IQ+FLOW Series, multiple channel arrangements can be realized on one compact manifold, with one multi-channel digital pc-board (per 3 channels) in one housing. \u003ch3\u003eCustomer Specific Designs\u003c\/h3\u003e A core philosophy of Bronkhorst is to form close working links and collaborations with Original Equipment Manufacturers (OEM) to ensure optimal integration of \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eflow instrumentation\u003c\/a\u003e within their own equipment. Often, this results in a custom design in which multiple channels and\/or various functions are combined into one micro fluidic system. \u003ch3\u003eApplications for IQ+FLOW Compact Flow Meter and Controller\u003c\/h3\u003e \u003cem\u003eExamples of analytical applications based on the ultra compact flow meter with a footprint of 0.75â are:\u003c\/em\u003e \u003cul\u003e \u003cli\u003eFlow control at the injector side of a \u003ca href=\"https:\/\/psctexas.com\/?s=gas+chromatograph\"\u003eGas Chromatograph (GC)\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eFlow control at the detector side of a GC or HPLC\u003c\/li\u003e \u003cli\u003eFlow control in an FID (Flame Ionization Detector)\u003c\/li\u003e \u003cli\u003eMonitoring of indoor air quality\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-flow-controllers-for-bacterial-growth-in-bioreactors\/\"\u003eGas dosing for bacterial growth\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-to-improve-your-gas-chromatography-analysis\/\"\u003eOther gas chromatography applications\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBioreactor Applications\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/gas-flow-controllers-for-bacterial-growth-in-bioreactors\/\"\u003eBioreactors and fermenters\u003c\/a\u003e play a vital role in \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\"\u003epharmaceutical research\u003c\/a\u003e for \u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\/\"\u003evaccine and medicine development\u003c\/a\u003e. Other bioreactor applications are the preparation of \u003ca href=\"https:\/\/psctexas.com\/benchtop-bioreactors-and-gas-flow-control\/\"\u003efermented foods and drinks\u003c\/a\u003e, biofuel, bio-based materials, and life science. Oxygen, nitrogen, carbon dioxide, and air are supplied to control the pH and dissolved oxygen level in the reactor chamber, hereby, controlling bacterial or cell growth. For optimum results, eachÂ gas flow needs to be controlled reliably and accurately, which requires Mass Flow Controllers. Frequently, small table-top sized models are used in \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003eResearch and Development\u003c\/a\u003e settings and for parallel experiments. IQ+FLOW multi-channel mass flow control solutions provide the worldâs smallest footprint and overall size for bioreactor flow control. So, this allows for weight reduction and easy electronic integration at the lowest cost per flow channel. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/IQFLOW-Compact-Flow-Meter-Controller-Bronkhorst-Low-Flow-Instrumentation-benchtop-bioreactors.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-21224 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/IQFLOW-Compact-Flow-Meter-Controller-Bronkhorst-Low-Flow-Instrumentation-benchtop-bioreactors.jpg\" alt=\"IQ+FLOW-Compact-Flow-Meter-Controller-Bronkhorst-Low-Flow-Instrumentation-benchtop-bioreactors\" width=\"792\" height=\"706\"\u003e\u003c\/a\u003e \u003cdiv class=\"page\" title=\"Page 4\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e A combination of these modules can be mounted on a compact manifold, in line with a customersâ requirements, and following open design discussions. Further possibilities might include either an aluminum or a stainless steel manifold with perhaps female inlet\/outlet ports that could be suitable for either gas or liquid. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371287171,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/iq-plus-flow-ultra-compact-mass-flow-meter-and-controller-pressure.jpg?v=1763385344"},{"product_id":"el-flow-base-series-thermal-mass-flow-controller","title":"EL-FLOW Base Series, Thermal Mass Flow Controller","description":"\u003cul\u003e \u003cli\u003eaccurate mass flow measurement\/control\u003c\/li\u003e \u003cli\u003efast response, excellent repeatability\u003c\/li\u003e \u003cli\u003evirtually pressure and temperature independent Cost effective solution\u003c\/li\u003e \u003cli\u003eanalog I\/O-signals: 0 to 5 (10) Vdc or 0(4)-20 mA RS232 communication\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus-RTU\u003c\/a\u003e or -ASCII\u003c\/li\u003e \u003cli\u003econtrol characteristics digitally configurable by user\u003c\/li\u003e \u003c\/ul\u003e \u003cimg class=\"alignright wp-image-9954\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/ELFlowBase-300x300.jpg\" alt=\"Bronkhorst-Low-Flow-Thermal-Mass-Flow-Meter\" width=\"500\" height=\"500\"\u003e \u003ch4 style=\"text-align: left;\"\u003eFields of Applications\u003c\/h4\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eprocess gas measurement and control in \u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003efood\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/how-mass-flow-controller-can-support-in-the-pharmaceutical-industry\/\"\u003epharmaceutical\u003c\/a\u003e and (petro)chemical industries and fermentation installations\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eburner control (welding)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/accurate-dosing-of-release-agent\/\"\u003esurface treatment (CVD, coating, hardening)\u003c\/a\u003e\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esolar cell fabrication analytical instrumentation\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch4 style=\"text-align: left;\"\u003eBurner Control\u003c\/h4\u003e Burner control using thermal mass flow controllers (MFC) brings many advantages compared to conventional systems, where flow is adjusted through needle valves. When burner orifices get clogged or when gas supply pressure varies, an MFC will automatically adapt to the changed conditions. \u003ch4 style=\"text-align: left;\"\u003eEL-FLOW Base Series Mass Flow Controller Model Line-Up\u003c\/h4\u003e \u003cem\u003eRanges based on Air, intermediate ranges available\u003c\/em\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eModel\u003c\/strong\u003e F-201CB \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003emin. flow\u003c\/strong\u003e 0.2...10 mln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003emax. flow\u003c\/strong\u003e 0.4...20 ln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e F-201AB \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.4...20 ln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4...70 ln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e F-202BB \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4...70 ln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 4...200 ln\/min \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371319939,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/ELFlowBase.jpg?v=1763385346"},{"product_id":"mass-view-series-compact-mass-flow-meters-regulators-controllers","title":"MASS-VIEW Series, Compact Mass Flow Meters, Regulators, Controllers","description":"The MASS-VIEW Series are accurate \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow instruments\u003c\/a\u003e for measuring and controlling the mass \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\/\"\u003eflow rate of gases\u003c\/a\u003e.Â They are an innovative series of mass flow meters, regulators, and controllers with integrated display. MASS-VIEW, from \u003ca href=\"https:\/\/psctexas.com\/brand\/bronkhorst\/\"\u003eBronkhorst\u003c\/a\u003e, provides a modern, novel, and economical alternative to rotameters, also known as variable area meters (VA meters) or purge meters. Unlike conventional rotameters, these flow meters measure the flow of mass instead of volume. For easy rotameter replacement, MASS-VIEWâs mechanical construction offers most of the common options for process connections. \u003cul\u003e \u003cli\u003eRS232 interface and \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus ASCII\/RTU\u003c\/a\u003e communication\u003c\/li\u003e \u003cli\u003econfigurable password protection\u003c\/li\u003e \u003cli\u003ealarm and counter functions\u003c\/li\u003e \u003cli\u003emulti-gas and multi-range\u003c\/li\u003e \u003cli\u003epreinstalled gas properties\u003c\/li\u003e \u003cli\u003edigitally calibrated\u003c\/li\u003e \u003cli\u003efree software tools\u003c\/li\u003e \u003c\/ul\u003e The MASS-VIEW Series operates on the principle of direct \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/thermal-mass-flow\/\"\u003ethermal mass flow measurement\u003c\/a\u003e (no bypass). An advantage of using this type of sensor is that these flow instruments measure direct mass flow, virtually independent of pressure and temperature changes, and have a low pressure drop.Â Other advantages compared to conventional rotameters are the high accuracy and the large rangeability. \u003cul\u003e \u003cli\u003eClear indication of: \u003cul\u003e \u003cli\u003eactual flow rate (bar graph and value) desired flow units\u003c\/li\u003e \u003cli\u003etype of gas\u003c\/li\u003e \u003cli\u003etotalized flow\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ebright, wide-angle OLED display\u003c\/li\u003e \u003cli\u003efree of parallax errors,Â high accuracy\u003c\/li\u003e \u003cli\u003evirtually independent of pressure and temperature variations\u003c\/li\u003e \u003cli\u003elow pressure drop,Â wide flow ranges,Â fast response\u003c\/li\u003e \u003cli\u003eelectronic output, analog (0-5 Vdc) and digital interface\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=J4wKXlOpQUo \u003ch3\u003eMASS-VIEW Series Thermal Mass Flow Meters\u003c\/h3\u003e The MASS-VIEW Series feature totalizer and alarm functions. Flow control can be achieved by an optional built-in needle valve. MASS-VIEW flow meters can be supplied in full scale ranges from 0.05 up to 500 l\u003csmall\u003en\u003c\/small\u003e\/min (air equivalent), with a pressure rating of 10 bar(g) or 150 psi(g). A bright graphical OLED display, clearly visible at wide angles, allows reading of actual flow (value and a bar graph), total flow, and gas type.Â The display features easy navigation through a user-friendly menu, using a 4-way button with center push. Furthermore, this low flow gas mass flow instrumentation has 2 potential free alarm contacts grounded on one side. An advantage of using this type of sensor is that the instrument measures direct mass flow, without the need of temperature and pressure correction. Other benefits, compared to conventional rotameters, are higher accuracy, wider rangeability (up to 1:100), free of parallax errors, and an inherently safer construction, by eliminating glass components in the flow path. \u003ch5\u003eMASS-VIEW Flow Meters and Regulators\u003c\/h5\u003e lowest range: 0-0.2 l\u003csmall\u003en\u003c\/small\u003e\/min highest range: 0-500 l\u003csmall\u003en\u003c\/small\u003e\/min \u003ch5\u003eMASS-VIEW Flow Controllers\u003c\/h5\u003e lowest range: 0-0.2 l\u003csmall\u003en\u003c\/small\u003e\/min highest range: 0-50 l\u003csmall\u003en\u003c\/small\u003e\/min * l\u003csmall\u003en\u003c\/small\u003e\/min equals SLM at 32ËF (0Â°C) and 1 atm (STP) \u003ch3\u003eDigital Replacement for Rotometers Meters, Variable Area (VA) Meters\u003c\/h3\u003e The display features easy set-up via a user-friendly menu using a 4-way navigation push button. Gas settings are preinstalled to eliminate the need to recalibrate for different gases, thereby reducing time and labor costs. Additional features and functions include a variety of alarm and counter functions, an analog output signal, digital interfaces, and two relay contacts. Flow control may be achieved with an optional needle valve. These high quality needle valves offer smooth and fine adjustment of the gas flow rates. The latest innovation to the MASS-VIEW product line is the addition of an integrated auto-compensating controller. The desired flow rate is set via the needle valve in the usual way, however, any upstream pressure variation is now automatically compensated to ensure a steady, constant flow. \u003ch3\u003eDigital Display with User-Friendly Interface\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The 4-way navigation push button provides access to a user-friendly menu, e.g. for zero function, selection of preinstalled gases in preinstalled capacities, setting of engineering units, alarm functions (minimum \/ maximum \/ counter limit), and counter functions. Also, password protection is provided to prevent unauthorized changes. These smart instruments offer multiple process values as input or output parameters. Many parameters can be changed on the instrument through the menu, other parameters can only be changed using \u003ca href=\"https:\/\/psctexas.com\/product\/mass-flow-controller-psc-6194\/\"\u003edigital interfaces\u003c\/a\u003e. \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The needle valve has an orifice with a long, tapered conical seat. A needle-shaped plunger, on the end of a screw, exactly fits this seat. As the screw is turned and the plunger retracted, so flow between the seat and the plunger increases. Since it takes many turns of the fine-threaded screw to retract the plunger, precise regulation of the flow rate is possible. \u003ch3\u003eConstant Flow Controller Principle\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Flow control with a needle valve at constant pressure results in a constant flow rate. But when pressure conditions change, the flow will also change.Â With a constant-flow controller with varying upstream pressure the flow will almost be constant. By keeping the pressure drop across a needle valve constant the flow rate also is constant. Deviations of the pressure drop are compensated by a membrane operated valve. This membrane is actuated by a spring. The spring force closes the valve. The equilibrium between closing (valve spring) and opening (membrane) keeps the flow constant. \u003cdiv class=\"page\" title=\"Page 8\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The spring force in the upstream membrane valve closes the valve in the âzeroâ flow situation. By opening the needle valve the ÎP will increase, so far that the membrane lifts up and compensates the spring force. In the equilibrium position the flow will be constant even when the upstream pressure (Pin) changes. However, when the upstream pressure increases, it will cause a small effect on the spring force, which means that the ÎP to open the membrane valve will be a little smaller. And this results in a lower flow. [caption id=\"attachment_22494\" align=\"aligncenter\" width=\"1000\"]\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/MASS-VIEW-Bronkhorst-Mass-Flow-Meter-Regulator-Rotometer-Replacement-Variable-Area-Meter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"wp-image-22494 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/MASS-VIEW-Bronkhorst-Mass-Flow-Meter-Regulator-Rotometer-Replacement-Variable-Area-Meter-Process-Solutions-Corp.jpg\" alt=\"MASS-VIEW-Bronkhorst-Mass-Flow-Meters-Regulator-Rotometer-Replacement-Variable-Area-Meter-Process-Solutions-Corp\" width=\"1000\" height=\"666\"\u003e\u003c\/a\u003e \u003ccenter\u003eIn practice, the deviation of the ideal straight line will be less than 0.5-1% per bar.\u003c\/center\u003e[\/caption] \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eDirect Flow Measurement Without Bypass\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The MASS-VIEW Series operates on the principle of direct thermal mass flow measurement. The thru-flow design sensor consists of a heater resistor and a temperature sensing resistor. Both resistors are made of temperature sensitive resistive material that is covered with a stainless steel tube. The necessary heating power to keep the temperature difference between the heater resistor and the sensing resistor at a constant level depends on the mass flow. A different and unique heater current is produced for each value of the flow. The measurement principle described is called Constant Temperature Anemometry (CTA). \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eCommon Uses of MASS-VIEW Digital Mass Flow Meters\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eburner control (furnace construction)\u003c\/li\u003e \u003cli\u003ewelding (welding gas monitoring)\u003c\/li\u003e \u003cli\u003eleak measurements (quality, \u003ca href=\"https:\/\/psctexas.com\/tag\/esg\/\"\u003eenvironment\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003ecoating (equipment construction)\u003c\/li\u003e \u003cli\u003eregulation of gaseous atmospheres (\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003ebiotechnology\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003emeasurement of gas consumption (\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003ehospitals\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003etest equipment (production maintenance)\u003c\/li\u003e \u003cli\u003elocal preparation of a gas mixture\u003c\/li\u003e \u003cli\u003eflow rate monitoring (\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003elaboratories\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003ecutting (steel sheets)\u003c\/li\u003e \u003cli\u003ecost center billing\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003eanalytical equipment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003eaeration \/ sparging (food products, ice cream \/ edible oils)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003eblanketing (food)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-controllers-for-bioreactors\/\"\u003efermentation (food, biotechnology, pharmaceuticals)\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371352707,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/mass-view-gas-mass-flow-meters-bronkhorst-digital-rotometer-alternative-process-solutions-corp-texas.png?v=1763385348"},{"product_id":"cori-flow-series-coriolis-mass-flow-meters-and-controllers","title":"CORI-FLOW Series, Coriolis Mass Flow Meters and Controllers","description":"\u003cul\u003e \u003cli\u003edirect mass flow measurement\u003c\/li\u003e \u003cli\u003efast response time\u003c\/li\u003e \u003cli\u003ehigh accuracy (0.2% Rd + ZS for liquids, 0.5% Rd + ZS for gases)\u003c\/li\u003e \u003cli\u003ehighly stable\u003c\/li\u003e \u003cli\u003ecompact Coriolis controller\u003c\/li\u003e \u003cli\u003eall wetted parts stainless steel; option: Hastelloy-C22\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 housing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eoptional: \u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX approval Cat.3, Zone 2\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eoptional: KCs certificate (Protection Ex nA IIC T4)\u003c\/li\u003e \u003cli\u003eanalog plus digital communication\u003c\/li\u003e \u003cli\u003eintegrated PID controller for control valve or pump\u003c\/li\u003e \u003cli\u003eintegrated totalizer for batch control\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=0LIUPP_fUIc \u003ch3\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003esemiconductor processing\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003efood and beverage industries\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e(petro)chemical installations\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/use-of-mass-flow-meters-in-the-automotive-industry\/\"\u003esurface treatment using spray dosing (paint, glue, resins, etc.)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etest bench for fuel testing\u003c\/li\u003e \u003cli\u003emicro reactor technology\u003c\/li\u003e \u003cli\u003eliquid mixing systems (cleaning fluid for contact lenses)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371385475,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CoriFlow.jpg?v=1763385349"},{"product_id":"mini-cori-flow-ex-d-series-coriolis-mass-flow-meters-and-controllers","title":"mini CORI-FLOW Ex d Series, Coriolis Mass Flow Meters and Controllers","description":"\u003cp\u003eThe mini CORI-FLOW Ex d Coriolis mass flow meter offers integrated PID control for direct control of valves or pumps, thus constituting compact \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/coriolis-flow-meters\" title=\"Coriolis Flow Meters\"\u003eCoriolis\u003c\/a\u003e mass flow control loops. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/flow-instrumentation\" title=\"Flow Instrumentation\"\u003eflow meter\u003c\/a\u003e can also come with valves or pumps for use in Zone 1, but they must install outside the mini CORI-FLOW Ex d box and connect via the screw terminal. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edirect mass flow measurement\u003c\/li\u003e\n\u003cli\u003efast response time\u003c\/li\u003e\n\u003cli\u003ehigh accuracy (0.2% Rd + ZS for liquids, 0.5% Rd + ZS for gases)\u003c\/li\u003e\n\u003cli\u003ehighly stable\u003c\/li\u003e\n\u003cli\u003ecompact Coriolis controller\u003c\/li\u003e\n\u003cli\u003eall wetted parts stainless steel; optional: Hastelloy-C22\u003c\/li\u003e\n\u003cli\u003eexplosion-proof housing for use in \u003ca title=\"IECEx Approvals\" href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e and \u003ca title=\"ATEX Certifications\" href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX Zone 1\u003c\/a\u003e rating \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 housing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eanalog plus digital communication\u003c\/li\u003e\n\u003cli\u003eintegrated PID controller for control valve or pump\u003c\/li\u003e\n\u003cli\u003eintegrated totalizer for batch control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCoriolis Flow Measurement Principle\u003c\/h2\u003e\n\u003cp\u003eThe mini CORI-FLOW Ex d Series Coriolis \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Meters and Controllers\"\u003elow flow\u003c\/a\u003e meters and controllers contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. Coriolis mass flow measurement is fast, accurate, and inherently bi-directional. The mini CORI-FLOW Ex d features density and temperature of the fluid as secondary outputs.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor Manufacturing\n\u003cul\u003e\n\u003cli\u003emass flow measurement and control of ultra low flow gas and liquid flows in wafer processing, etching, and deposition processes\u003c\/li\u003e\n\u003cli\u003ecritical fluid control in cleanroom environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood, Beverage, and Pharmaceutical Production\n\u003cul\u003e\n\u003cli\u003eaccurate mass dosing of flavors, sweeteners, vitamins, or preservatives at very low flow rates\u003c\/li\u003e\n\u003cli\u003eensuring consistent, repeatable product quality and taste\u003c\/li\u003e\n\u003cli\u003econtrolled delivery of active ingredients, solvents, and reagents in batch processes\u003c\/li\u003e\n\u003cli\u003eenvironments where solvent vapors pose a risk of ignition or explosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eChemicals and Petrochemical Plants\n\u003cul\u003e\n\u003cli\u003eprecise dosing of catalysts, additives, and inhibitors in chemical processing\u003c\/li\u003e\n\u003cli\u003eflow measurement in processes with hazardous or flammable fluids\u003c\/li\u003e\n\u003cli\u003econtrolled injection of odorant compounds into natural gas streams for safety and regulatory compliance, for example, THT dosing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLaboratories, Research, and Pilot Plants\n\u003cul\u003e\n\u003cli\u003edevelopment and testing of new processes with small-scale flow control\u003c\/li\u003e\n\u003cli\u003eprecise flow measurement in research involving hazardous chemicals or gases\u003c\/li\u003e\n\u003cli\u003emonitoring supercritical CO\u003csmall\u003e2\u003c\/small\u003e extraction flows, solvent dosing, or other anallytical processes where mass accuracy is crucial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bronkhorst","offers":[{"title":"XM12 \/ A: None - Standard; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605927907459,"sku":"XM12AA","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ A: None - Standard; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605927940227,"sku":"XM12AB","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ A: None - Standard; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605927972995,"sku":"XM12AF","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ A: None - Standard; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928005763,"sku":"XM12AG","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ B: None - Standard; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928038531,"sku":"XM12BA","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ B: None - Standard; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928071299,"sku":"XM12BB","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ B: None - Standard; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928104067,"sku":"XM12BF","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ B: None - Standard; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928136835,"sku":"XM12BG","price":12713.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ D: add DeviceNet; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928169603,"sku":"XM12DA","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ D: add DeviceNet; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928202371,"sku":"XM12DB","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ D: add DeviceNet; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928235139,"sku":"XM12DF","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ D: add DeviceNet; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928267907,"sku":"XM12DG","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ E: add DeviceNet; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928300675,"sku":"XM12EA","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ E: add DeviceNet; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928333443,"sku":"XM12EB","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ E: add DeviceNet; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928366211,"sku":"XM12EF","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ E: add DeviceNet; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928398979,"sku":"XM12EG","price":13115.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ M: add Modbus; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928431747,"sku":"XM12MA","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ M: add Modbus; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928464515,"sku":"XM12MB","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ M: add Modbus; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928497283,"sku":"XM12MF","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ M: add Modbus; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928530051,"sku":"XM12MG","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ N: add Modbus; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928562819,"sku":"XM12NA","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ N: add Modbus; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928595587,"sku":"XM12NB","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ N: add Modbus; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928628355,"sku":"XM12NF","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ N: add Modbus; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928661123,"sku":"XM12NG","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ P: add PROFIBUS-DP; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928693891,"sku":"XM12PA","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ P: add PROFIBUS-DP; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928726659,"sku":"XM12PB","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ P: add PROFIBUS-DP; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928759427,"sku":"XM12PF","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ P: add PROFIBUS-DP; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928792195,"sku":"XM12PG","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ Q: add PROFIBUS-DP; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928824963,"sku":"XM12QA","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ Q: add PROFIBUS-DP; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928857731,"sku":"XM12QB","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ Q: add PROFIBUS-DP; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605928890499,"sku":"XM12QF","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ Q: add PROFIBUS-DP; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605928923267,"sku":"XM12QG","price":13129.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ R: add FLOW-BUS; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605928956035,"sku":"XM12RA","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ R: add FLOW-BUS; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605928988803,"sku":"XM12RB","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ R: add FLOW-BUS; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929021571,"sku":"XM12RF","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ R: add FLOW-BUS; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929054339,"sku":"XM12RG","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ S: add FLOW-BUS; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605929087107,"sku":"XM12SA","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ S: add FLOW-BUS; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605929119875,"sku":"XM12SB","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ S: add FLOW-BUS; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929152643,"sku":"XM12SF","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM12 \/ S: add FLOW-BUS; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929185411,"sku":"XM12SG","price":13072.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ A: None - Standard; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605929480323,"sku":"XM13AA","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ A: None - Standard; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605929513091,"sku":"XM13AB","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ A: None - Standard; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929545859,"sku":"XM13AF","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ A: None - Standard; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929578627,"sku":"XM13AG","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ B: None - Standard; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605929611395,"sku":"XM13BA","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ B: None - Standard; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605929644163,"sku":"XM13BB","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ B: None - Standard; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929676931,"sku":"XM13BF","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ B: None - Standard; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929709699,"sku":"XM13BG","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ D: add DeviceNet; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605929742467,"sku":"XM13DA","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ D: add DeviceNet; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605929775235,"sku":"XM13DB","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ D: add DeviceNet; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929808003,"sku":"XM13DF","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ D: add DeviceNet; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929840771,"sku":"XM13DG","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ E: add DeviceNet; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605929873539,"sku":"XM13EA","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ E: add DeviceNet; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605929906307,"sku":"XM13EB","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ E: add DeviceNet; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605929939075,"sku":"XM13EF","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ E: add DeviceNet; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605929971843,"sku":"XM13EG","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ M: add Modbus; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930004611,"sku":"XM13MA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ M: add Modbus; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930037379,"sku":"XM13MB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ M: add Modbus; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930070147,"sku":"XM13MF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ M: add Modbus; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930102915,"sku":"XM13MG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ N: add Modbus; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930135683,"sku":"XM13NA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ N: add Modbus; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930168451,"sku":"XM13NB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ N: add Modbus; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930201219,"sku":"XM13NF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ N: add Modbus; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930233987,"sku":"XM13NG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ P: add PROFIBUS-DP; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930266755,"sku":"XM13PA","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ P: add PROFIBUS-DP; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930299523,"sku":"XM13PB","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ P: add PROFIBUS-DP; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930332291,"sku":"XM13PF","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ P: add PROFIBUS-DP; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930365059,"sku":"XM13PG","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ Q: add PROFIBUS-DP; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930397827,"sku":"XM13QA","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ Q: add PROFIBUS-DP; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930430595,"sku":"XM13QB","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ Q: add PROFIBUS-DP; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930463363,"sku":"XM13QF","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ Q: add PROFIBUS-DP; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930496131,"sku":"XM13QG","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ R: add FLOW-BUS; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930528899,"sku":"XM13RA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ R: add FLOW-BUS; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930561667,"sku":"XM13RB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ R: add FLOW-BUS; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930594435,"sku":"XM13RF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ R: add FLOW-BUS; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930627203,"sku":"XM13RG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ S: add FLOW-BUS; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605930659971,"sku":"XM13SA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ S: add FLOW-BUS; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605930692739,"sku":"XM13SB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ S: add FLOW-BUS; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605930725507,"sku":"XM13SF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM13 \/ S: add FLOW-BUS; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605930758275,"sku":"XM13SG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ A: None - Standard; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931053187,"sku":"XM14AA","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ A: None - Standard; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931085955,"sku":"XM14AB","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ A: None - Standard; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931118723,"sku":"XM14AF","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ A: None - Standard; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931151491,"sku":"XM14AG","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ B: None - Standard; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931184259,"sku":"XM14BA","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ B: None - Standard; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931217027,"sku":"XM14BB","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ B: None - Standard; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931249795,"sku":"XM14BF","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ B: None - Standard; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931282563,"sku":"XM14BG","price":11895.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ D: add DeviceNet; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931315331,"sku":"XM14DA","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ D: add DeviceNet; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931348099,"sku":"XM14DB","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ D: add DeviceNet; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931380867,"sku":"XM14DF","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ D: add DeviceNet; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931413635,"sku":"XM14DG","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ E: add DeviceNet; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931446403,"sku":"XM14EA","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ E: add DeviceNet; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931479171,"sku":"XM14EB","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ E: add DeviceNet; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931511939,"sku":"XM14EF","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ E: add DeviceNet; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931544707,"sku":"XM14EG","price":12297.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ M: add Modbus; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931577475,"sku":"XM14MA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ M: add Modbus; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931610243,"sku":"XM14MB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ M: add Modbus; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931643011,"sku":"XM14MF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ M: add Modbus; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931675779,"sku":"XM14MG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ N: add Modbus; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931708547,"sku":"XM14NA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ N: add Modbus; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931741315,"sku":"XM14NB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ N: add Modbus; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931774083,"sku":"XM14NF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ N: add Modbus; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931806851,"sku":"XM14NG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ P: add PROFIBUS-DP; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931839619,"sku":"XM14PA","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ P: add PROFIBUS-DP; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605931872387,"sku":"XM14PB","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ P: add PROFIBUS-DP; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605931905155,"sku":"XM14PF","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ P: add PROFIBUS-DP; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605931937923,"sku":"XM14PG","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ Q: add PROFIBUS-DP; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605931970691,"sku":"XM14QA","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ Q: add PROFIBUS-DP; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605932003459,"sku":"XM14QB","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ Q: add PROFIBUS-DP; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605932036227,"sku":"XM14QF","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ Q: add PROFIBUS-DP; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605932068995,"sku":"XM14QG","price":12311.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ R: add FLOW-BUS; Normally Closed \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605932101763,"sku":"XM14RA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ R: add FLOW-BUS; Normally Closed \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605932134531,"sku":"XM14RB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ R: add FLOW-BUS; Normally Closed \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605932167299,"sku":"XM14RF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ R: add FLOW-BUS; Normally Closed \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605932200067,"sku":"XM14RG","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ S: add FLOW-BUS; Normally Open \/ A: 0-5 V; 0-5 V or digital 0-100%","offer_id":46605932232835,"sku":"XM14SA","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ S: add FLOW-BUS; Normally Open \/ B: 0-10 V; 0-10 V or digital 0-100%","offer_id":46605932265603,"sku":"XM14SB","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ S: add FLOW-BUS; Normally Open \/ F: 0-20 mA sourcing; 0-20 mA or digital 0-100%","offer_id":46605932298371,"sku":"XM14SF","price":12254.0,"currency_code":"USD","in_stock":true},{"title":"XM14 \/ S: add FLOW-BUS; Normally Open \/ G: 4-20 mA sourcing; 4-20 mA or digital 0-100%","offer_id":46605932331139,"sku":"XM14SG","price":12254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/MiniFlow.jpg?v=1763385462"},{"product_id":"mini-cori-flow-series-coriolis-flow-meter-and-controller","title":"mini CORI-FLOW Series, Coriolis Flow Meter and Controller","description":"\u003cp\u003eThe mini CORI-FLOW is a compact, high-precision \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/coriolis-flow-meters\" title=\"Coriolis Flow Meters\"\u003eCoriolis\u003c\/a\u003e flow meter and controller for both liquids and gases. Employing the established Coriolis measurement principle, it delivers direct mass-flow readings that are independent of fluid properties. Thus, Coriolis flow meters enable superior accuracy, repeatability and reliability. With integrated PID controller functionality, the mini CORI-FLOW allows precise dosing via pumps or shut-off valves without a separate \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eTherefore, it's ideal for applications such as additive dosing in food \u0026amp; beverage, chemical pilot plants, or catalyst injection. Its compact size makes it an excellent choice for constrained spaces, for example, laboratories, OEM installations or pilot-scale systems. Furthermore, it offers advanced communication protocols for modern integration. This Coriolis flow meter supports a wide range of flow rates (from very low to several hundred kilograms per hour), and is also built for demanding environments including hazardous areas (Zone 1\/2).\u003c\/p\u003e\n\u003cp\u003eTemperature as well as density measurement channels, along with multi-parameter capabilities, expand its utility beyond mere flow rate monitoring to full process control. Whether your process involves high-pressure dosing, ultra-low-flow metering or highly repeatable additive injection, the mini CORI-FLOW offers a reliable, turnkey solution for demanding mass flow measurement needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect mass flow measurement, for liquids and gases\u003c\/li\u003e\n\u003cli\u003eHigh accuracy, excellent repeatability\u003c\/li\u003e\n\u003cli\u003eCost-effective design\u003c\/li\u003e\n\u003cli\u003eCompact design, with integrated PID controller for fast and stable control\u003c\/li\u003e\n\u003cli\u003eNow suitable for (very) low flow ranges\u003c\/li\u003e\n\u003cli\u003eDigital technology allows Fieldbus communication and offers user configurable control characteristics\u003c\/li\u003e\n\u003cli\u003eOptional \u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\" title=\"UL Standards for ATEX Certification\"\u003eATEX approval Cat.3, Zone 2 rating\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional KCs certificate (Protection Ex nA IIC T4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ccenter\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/z5utL9Cy6b4?si=FKYGOUd5X4qQk14_\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003ccenter\u003e\u003c\/center\u003e\n\u003ch2\u003eUsing a Coriolis Flow Meter as an Alternative to Thermal Mass Flow Meters\u003c\/h2\u003e\n\u003cp\u003eThe mini CORI-FLOW Series was designed to enable easy exchange of traditional thermal mass flow controllers. mini CORI-FLOW flow controllers also have the same footprint and also electrically the instruments feature the same options for analog and Fieldbus communication. Compared to thermal mass flow controllers, Coriolis based flow controllers are more accurate, faster, and offer independence from fluid properties.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBronkhorst mini CORI-FLOW with Digital Technology\u003c\/h2\u003e\n\u003cp\u003eThe mini CORI-FLOW Series features state-of-the-art digital technology, thus offering Fieldbus interface options and additional functions such as totalization and alarms. The instruments can be tuned according to customer requirements using the RS232 and Fieldbus interface and a number of free to use software tools. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications of a Coriolis Flow Meter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAnalytical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/products\/liquid-dosing-system\" title=\"Liquid Dosing Systems\"\u003eDosing\u003c\/a\u003e of additives in food and beverage industries\u003c\/li\u003e\n\u003cli\u003ePetrochemical and chemical plants\u003c\/li\u003e\n\u003cli\u003ePilot plants\u003c\/li\u003e\n\u003cli\u003eCVD\/Coating systems\u003c\/li\u003e\n\u003cli\u003eSemiconductor processing\u003c\/li\u003e\n\u003cli\u003eLiquid CO\u003csmall\u003e2\u003c\/small\u003e dosing for polystyrene foam extrusion\u003c\/li\u003e\n\u003cli\u003eCatalysis at high pressure\u003c\/li\u003e\n\u003cli\u003eDosing of additives for example, flavors and fragrances\u003c\/li\u003e\n\u003cli\u003eBetter control of microbiological processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ccenter\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/hTQBn4H4puI?si=ErqPVj7TH_mZjlA1\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/center\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878381117571,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Coriolis-Flow-Meter-Group-mini-CORI-FLOW.jpg?v=1763385607"},{"product_id":"kayden-classic-800-series-switch-and-transmitter","title":"Kayden CLASSIC 800 Series, Switch and Transmitter","description":"\u003cp\u003eThe CLASSIC 800 Series features switches and transmitters for flow, level, interface, and temperature process control. Each model has a precision welded, highly accurate stainless steel thermal sensor. The \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 800 Series is ideal for liquids, gases, and slurries in clean or dirty processes. Options for process connections include: raised face, RTJ flange, threaded, or retractable packing glands. In addition, all Kayden CLASSIC models feature a rugged flameproof enclosure with blind or lens cover options. Its advanced digital electronics will revolutionize the way you monitor and control your process.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e\n\u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e\n\u003cli\u003etemperature compensation\u003c\/li\u003e\n\u003cli\u003euniversal power 12-24 VDC and 115-230 VAC standard\u003c\/li\u003e\n\u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e\n\u003cli\u003e4-20 mA analog output\u003c\/li\u003e\n\u003cli\u003esmart heater function for power economy and increased heater life\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKayden CLASSIC 800 Series Model Line Up\u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003eKayden CLASSIC 810 - Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections - MNPT\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1\/2 inch, 3\/4 inch, 1.0 inches, 1 1\/4 inches, 1 1\/2 inches, 2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-812-flanged-thermal-sensor-flow-meter-level-switch-and-transmitter-interface\/\"\u003eKayden CLASSIC 812 - Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814 - Flanged Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eretractable packing gland, raised face, or RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816 - Threaded Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethreaded retractable packing gland (1\" MNPT)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830 - In-Line Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832 - In-Line Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Kayden CLASSIC 800 Series*\u003c\/h3\u003e\n\u003cp\u003e*options vary by model selection\u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow\u003c\/li\u003e\n\u003cli\u003elevel\u003c\/li\u003e\n\u003cli\u003einterface\u003c\/li\u003e\n\u003cli\u003etemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eProcess Connections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003cli\u003eflanged in-line\u003c\/li\u003e\n\u003cli\u003e MNPT\n\u003cul\u003e\n\u003cli\u003e1\/2 inch\u003c\/li\u003e\n\u003cli\u003e3\/4 inch\u003c\/li\u003e\n\u003cli\u003e1 inch\u003c\/li\u003e\n\u003cli\u003e1-1\/4 inches\u003c\/li\u003e\n\u003cli\u003e1-1\/2 inches\u003c\/li\u003e\n\u003cli\u003e2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 to 3.5 inches Tri-Clamp\n\u003cul\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003cli\u003esanitary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eretractable packing glands\n\u003cul\u003e\n\u003cli\u003ethreaded (1” MNPT)\u003c\/li\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSanitary Tri-Clamp Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eFlanged Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h4\u003e\n\u003cp\u003eStandard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1.2 inches (3 cm)\u003c\/li\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003cli\u003e9 inches (23 cm)\u003c\/li\u003e\n\u003cli\u003e12 inches (30 cm)\u003c\/li\u003e\n\u003cli\u003e18 inches (45 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKayden CLASSIC 828 (Sanitary)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCustom Lengths\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e\n\u003cli\u003eKayden CLASSIC model dependent: minimum 1.2 inches (3 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInput Power Options\u003c\/h4\u003e\n\u003cp\u003eUniversal Power Standard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12-24 VDC\u003c\/li\u003e\n\u003cli\u003e115-230 VAC\u003c\/li\u003e\n\u003cli\u003e50-60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConsumption\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emaximum: 6.0 watts (fully configured)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4-20 mA current loop\u003c\/li\u003e\n\u003cli\u003etwo (2) independent SPDT sealed relay contacts\n\u003cul\u003e\n\u003cli\u003erated at 4 amps resistive 230 VAC or 30 VDC maximum\u003c\/li\u003e\n\u003cli\u003eindividually adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAccuracy\u003c\/h4\u003e\n\u003cp\u003eFlow Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±1% set point velocity over operating range of ±50˚F (±28˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLevel Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±0.25 inches (±0.64 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResponse Time\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eapproximately 0.5 to 30 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRemote Electronics Options\u003c\/h4\u003e\n\u003cp\u003eMaximum Recommended \u003ca href=\"https:\/\/psctexas.com\/product-category\/cables\/\"\u003eCable Length\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200 feet (60 meters)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCable Type\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 AWG minimum\u003c\/li\u003e\n\u003cli\u003etwisted pairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHeater Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003efield adjustable to optimize performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStart Up Bypass Timer\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable for 0 to 100 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e via RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Pressure (Maximum)\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 MPa (3500 psig) dependent on Kayden CLASSIC model and material of construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTemperature Range (Sensor)\u003c\/h4\u003e\n\u003cp\u003eContinuous Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-50 to 392˚F (-45 to 200˚C)\u003c\/li\u003e\n\u003cli\u003e-40 to 320˚F (-40 to 160˚C) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectronics\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-67˚F to 149˚F (-55˚C to 65˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: For temperatures above 149˚F (65˚C), electronics must be remotely mounted. Storage\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Kayden CLASSIC models should be stored in a clean and dry environment between -34.5 to 140˚F (-30 to 60˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnclosure Material\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecopper-free aluminum (does not exceed 0.4% copper)\u003c\/li\u003e\n\u003cli\u003epowder coated polyester TGIC (polyester triglycidyl isocyanurate)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4\u003c\/a\u003e \/ Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1” FNPT conduit connection\u003c\/li\u003e\n\u003cli\u003ebuna o-ring on cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConduit Connection Cover\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWetted Materials\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e - standard\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e grade 2\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e316\/316L stainless steel with nickel braze [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003ehighly saturated nitrile (pressure seal) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003eother wetted material options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003erated:\n\u003cul\u003e\n\u003cli\u003e120 Vac max\u003c\/li\u003e\n\u003cli\u003e30 Vdc max\u003c\/li\u003e\n\u003cli\u003e4A max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, Insertion Style\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 3.0 feet\/second (0.003 to 0.9 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 5.0 feet\/second (0.003 to 1.5 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.25 to 254 sfps (0.076 to 77 smps)\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, In-Line Models\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.015 to 50 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.033 to 110 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.6 to 20,000 cc\/second\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C ) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eRCMS (Remote Control \u0026amp; Monitoring Software) Functions and Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edisplay panel lock-out\u003c\/li\u003e\n\u003cli\u003eset points configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003erelay actuation delay timer\u003c\/li\u003e\n\u003cli\u003eindependently configurable for both on and off \/ increasing or decreasing\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 5,000 seconds\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 100 seconds\u003c\/li\u003e\n\u003cli\u003erelay mode configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eenergized above or below set point\u003c\/li\u003e\n\u003cli\u003erelay temperature mode configuration\u003c\/li\u003e\n\u003cli\u003eheater power setting\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ezero and span settings\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eanalog (4-20 mA) output configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eview and print graphing (trend) function\u003c\/li\u003e\n\u003cli\u003econfiguring settings; write to device, save to file, and print\u003c\/li\u003e\n\u003cli\u003efault event log\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003ealso configurable from display panel\u003c\/p\u003e\n\u003ch4\u003eWeights and Dimensions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003e810 threaded\u003c\/a\u003e: 2\" 'U' length: 7 pounds (3.18 kg)\u003c\/li\u003e\n\u003cli\u003ecarton size: 15x5x6 inches (38x13x15 cm)\u003c\/li\u003e\n\u003cli\u003eother models\/sizes: \u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us for more information\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWarranty\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eone (1) year from shipment date from factory (see full Terms and Conditions for details)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDisplay Panel Indicators\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003erelay 1 and 2\u003c\/li\u003e\n\u003cli\u003eset point 1 and 2\u003c\/li\u003e\n\u003cli\u003efault alarm\u003c\/li\u003e\n\u003cli\u003erun mode\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration Mode Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable sensitivity\u003c\/li\u003e\n\u003cli\u003ezero and span adjustment\u003c\/li\u003e\n\u003cli\u003eModbus addressable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eprimary watchdog circuit monitors microprocessor parameter anomalies\u003c\/li\u003e\n\u003cli\u003esecondary watchdog circuit monitors microprocessor health\u003c\/li\u003e\n\u003cli\u003eheater monitored for out-of-range conditions\u003c\/li\u003e\n\u003cli\u003efault mode de-energizes relay(s) and halts power to the heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApprovals and Certifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\"\u003eCSA Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eANSI\/UL Class I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eEx d IIB + H2\u003c\/li\u003e\n\u003cli\u003eAEx d IIB+H2 (Class I, Zone 1, Group IIB + H2,) T3\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSingle Seal Approval\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePer \u003ca rel=\"nofollow noopener\" href=\"https:\/\/webstore.ansi.org\/\" target=\"_blank\"\u003eANSI\u003c\/a\u003e\/ISA 12.27.01-2003\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\"\u003eFM Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 1, AEx d IIB+H2 T2D (Ta=75˚C) \/ T3 (Ta=65˚C)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCRN Canadian Registration Number\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCRN approvals available\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us\u003c\/a\u003e for CRN information per model and jurisdiction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003ch2 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h2\u003e\n\u003ch4\u003eFlow\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow switch for pump protection - dry alarm\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etank overflow protection\u003c\/li\u003e\n\u003cli\u003eflare gas monitoring\u003c\/li\u003e\n\u003cli\u003emonitoring purge air flow\u003c\/li\u003e\n\u003cli\u003elube oil systems\u003c\/li\u003e\n\u003cli\u003event monitoring\u003c\/li\u003e\n\u003cli\u003enatural gas to boilers\u003c\/li\u003e\n\u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e\n\u003cli\u003edrain line flow\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etanker loading and unloading\u003c\/li\u003e\n\u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e\n\u003cli\u003eremote indication of flow via analog and digital output communications\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLevel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003estorage tanks\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e\n\u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e\n\u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e\n\u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e\n\u003cli\u003etank overflow\u003c\/li\u003e\n\u003cli\u003esampler systems\u003c\/li\u003e\n\u003cli\u003esand separators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInterface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003econtrol in separation vessels\u003c\/li\u003e\n\u003cli\u003edetection\u003c\/li\u003e\n\u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMedia\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eliquids, air, and gases\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e\n\u003cli\u003eslurries\u003c\/li\u003e\n\u003cli\u003ecorrosive liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eProcess Conditions for this Switch \/ Transmitter for Flow, Level, Interface, and Temperature\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eFlow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003eclean and dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eLevel\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003cli\u003enon-turbulent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eInterface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003edry gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878381183107,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-800-Series-Flow-Meter-Level-Switch-Interface-Switches-Temperature-Transmitter-Process-Solutions-Texas.png?v=1763385608"},{"product_id":"flexi-flow-gas-mass-compact-flow-meter-and-controller","title":"FLEXI-FLOW Compact Flow Meter and Controller for Gas","description":"\u003cp\u003eThe FLEXI-FLOW Series is ideal for accurate measurement of \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Instrumentation\"\u003elow flow\u003c\/a\u003e ranges between 0-500 ml\u003csmall\u003en\u003c\/small\u003e\/min and 0-20 l\u003csmall\u003en\u003c\/small\u003e\/min at operating pressures between vacuum and 17 bar(a). The compact FLEXI-FLOW \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/flow-instrumentation\" title=\"Flow Meters and Controllers\"\u003eflow meter\u003c\/a\u003e and controller, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/bronkhorst\" title=\"Bronkhorst Low Flow Instrumentation\"\u003eBronkhorst\u003c\/a\u003e, combines a swift and stable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/thermal-flow-meters\" title=\"Thermal Flow Meters\"\u003ethermal mass flow\u003c\/a\u003e sensor based on capillary \u003ca href=\"https:\/\/psctexas.com\/mems-tech\/\" title=\"MEMs Technology\" target=\"_blank\"\u003eMEMS technology\u003c\/a\u003e with a precise and proven by-pass construction.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 control types in one compact instrument\n\u003cul\u003e\n\u003cli\u003eMass flow\u003c\/li\u003e\n\u003cli\u003eUpstream pressure\u003c\/li\u003e\n\u003cli\u003eDownstream pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMulti-parameter output\n\u003cul\u003e\n\u003cli\u003eActual mass flow\u003c\/li\u003e\n\u003cli\u003eUpstream pressure\u003c\/li\u003e\n\u003cli\u003eDownstream pressure\u003c\/li\u003e\n\u003cli\u003eTemperature (instrument)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh accuracy through on-board gas database and real-time conversion\u003c\/li\u003e\n\u003cli\u003eEasy to configure\u003c\/li\u003e\n\u003cli\u003eMTBF 145 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMultifunctional Compact Flow Meter from Bronkhorst\u003c\/h2\u003e\n\u003cp\u003eDue to the unique \u003ca href=\"https:\/\/psctexas.com\/mass-flow-control-redefined-swift-and-stable-proven-and-precise\/\" title=\"Swift and Stable Flow Measurement\"\u003eTCS Technology\u003c\/a\u003e (Through Chip Sensor), accurate mass flow measurement, virtual independence of variations in temperature and line pressure is established. In combination with integrated temperature and upstream and downstream pressure sensors, the embedded database for 22 gases allows accurate, on-board conversion.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-board gas conversion model\u003c\/li\u003e\n\u003cli\u003e22 unique gases embedded\u003c\/li\u003e\n\u003cli\u003eMulti-parameter output: mass flow, temperature, and pressure\u003c\/li\u003e\n\u003cli\u003eSimple and secure connection through \u003ca title=\"Bluetooth Association\" href=\"https:\/\/www.bluetooth.com\/\" target=\"_blank\"\u003eBluetooth\u003c\/a\u003e or USB-C\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR NE107 status indication\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy, Plug-and-Play Flow Control with the PSC6194\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca title=\"FlowLogic Flow Control System and Readout\" href=\"https:\/\/www.psctexas.shop\/products\/flowlogic-flow-control-system-readout\"\u003eFlowLogic\u003c\/a\u003e plug-and-play flow control system and readout, from Process Solutions Corp., is an ideal plug-and-play flow controller with built-in logic and control functions. Since the FLEXI-FLOW does not have serial communications available, unlike many other Bronkhorst flow instrumentation, using a laptop isn't an easy option. The PSC6194 is designed and programmed by Process Solutions Corp. specifically for use with Bronkhorst flow meters and controllers. The PSC6194 is an all-in-one flow controller system that comes preprogrammed with standard flow control functions for a user friendly interface. The touchscreen HMI offers intuitive control and is capable of data logging and other functions that are useful for batching or continuous production processes. While standard packages are available, our engineers can work closely with your team to develop a unique system that fits every requirement for your application. Whether your process involves gas flow or liquid flow such as liquid dosing applications, the PSC6194 offers easy but powerful control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures of the PSC6194 Flow Controller\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog and Modbus Interface\u003c\/li\u003e\n\u003cli\u003eData logging capabilities\u003c\/li\u003e\n\u003cli\u003eIndication and Operation of:\n\u003cul\u003e\n\u003cli\u003eMeasured Value\u003c\/li\u003e\n\u003cli\u003eSetpoint\u003c\/li\u003e\n\u003cli\u003eInstrument Range\u003c\/li\u003e\n\u003cli\u003eTrending Values Totalizer (limit, value, totalizer mode, new setpoint)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFully Customizable, Compact Flow Meters and Controllers\u003c\/h4\u003e\n\u003cp\u003eThe FLEXI-FLOW concept offers the option of built-to-order designs for OEM customers, in which various multiple channels Mass Flow \u0026amp; Pressure Meters \/ Controllers are combined into one microfluidic system. The following functional modules can be configured into one compact sub-system: mass flow meter or controller, pressure meter or controller, shut-off valve, mixing chamber. Such a ”plug and perform” assembly ensures space efficiency, cost reduction and a minimum of potential leak points.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompact assembly ensures space efficiency\u003c\/li\u003e\n\u003cli\u003eEconomical solution, low cost of ownership\u003c\/li\u003e\n\u003cli\u003eCombination of functions on one assembly (i.e. tubeless construction) reduces potential leak points\u003c\/li\u003e\n\u003cli\u003ePre-tested \"Plug and Play\" units, reducing custom testing requirements\u003c\/li\u003e\n\u003cli\u003eMulti-bus communication interface by gateway (\u003ca href=\"https:\/\/psctexas.com\/product-tag\/ethernet-enabled\/\"\u003eEthernet\u003c\/a\u003e, CAN, and Serial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTCS Technology for High Accuracy Low Flow Meters\u003c\/h4\u003e\n\u003cp\u003eBronkhorst has created a completely new concept for measuring mass flow using the thermal measuring principle. The unique TCS Technology (Through Chip Sensor) combines the best of two technologies: a fast and stable chip flow sensor applied in Bronkhorst's proven by-pass construction. Due to the TCS Technology, accurate mass flow measurement, virtual independent of variations in temperature and line pressure is established. By measuring the actual process conditions (temperature and line pressure), a real-time correction is made to the measured value. And because all gas properties are available on-board, accurate conversion to other gases is possible. Due to the ultra-thin sensor tube, the sensor reacts instantaneously to changes of the gas flow, resulting in very fast flow measurement. Combined with a direct acting control valve, settling times smaller than 150 ms are achieved. Besides mass flow measurement, the instrument has an integrated temperature sensor and 2 pressure sensors (instrument inlet and outlet pressure). These measurement parameters do not only provide information about the instrument but also about the process conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOn-board FLUIDAT Gas Database\u003c\/h4\u003e\n\u003cp\u003eSelect your process gas. With 22 on-board gases, it is very easy to switch to another gas or mixture. Additionally, the on-board gas database is used for real-time corrections on the flow measurement based on the actual process conditions (temperature and line pressure). The instrument shows the status of self-monitoring and diagnosis by means of a coloured LED. This signal can be easily recognized by the operator. For more details the diagnostic parameters can be used. We have been able to reduce the footprint by 35% compared to similar instruments up to 20 l\u003csmall\u003en\u003c\/small\u003e\/min. Due to this \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact size\u003c\/a\u003e, the instrument is very suitable to be used inside desktop equipment or at places where space is limited.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eUSB-C and Bluetooth Communication Interface\u003c\/h4\u003e\n\u003cp\u003eFor easy setup outside the installation, the USB-C port can be used. Communication can be established with the Bronkhorst FlowSuite software without the need of an additional power supply. During operation, this port can also be used to monitor the instrument without disconnecting the power and data connection. To enhance user flexibility, a wireless connection allows monitoring the instrument without disconnecting the regular power and data connection. In case Bluetooth is not desired, this function can be disabled.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSustainable, Environmentally Friendly, Predictive Maintenance\u003c\/h4\u003e\n\u003cp\u003eDue to the accurate conversion, calibration with valuable or rare gases is no longer necessary. In addition, Bronkhorst's products are known for their low power consumption. The reduced size and weight of the instrument minimizes its environmental impact. Prepared for predictive maintenance and diagnostic functions by means of datalogging of several parameters, that can be used to predict the health status of the instrument and condition of the process. With multiple configurable alarms the information can be transferred to the user.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eMulti-Channel Systems\u003c\/h4\u003e\n\u003cp\u003eFLEXI-FLOW Compact instruments can be combined to build a compact system that is ready to use. Multi-channel systems up to 8 channels can be easily created with the help of configuration software. The use of distribution chambers at the inlet or mixing chambers at the outlet ensures a compact and small build of the system. Communication from the multi-channel system to the PLC can be established with additional gateways. Since the system is completely assembled and tested at Bronkhorst, the effort required for commissioning is kept to a minimum.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eCommon Uses of FLEXI-FLOW Low Flow Meter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBioprocessing systems\u003c\/li\u003e\n\u003cli\u003eAnalytical applications\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Fuel Cell Research and Testing via Mass Flow Control\" href=\"https:\/\/psctexas.com\/fuel-cell-research-and-testing-by-mass-flow-control\/\" target=\"_blank\"\u003eFuel cell stack leak testing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Stable and Fast Gas Flow Control for Vacuum Deposition\" href=\"https:\/\/psctexas.com\/stable-and-fast-gas-flow-control-for-vacuum-deposition\/\" target=\"_blank\"\u003eReactive sputtering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eBronkhorst FLEXI-FLOW Compact Series Model Line-up\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePreconfigured Advanced (PA), Mass Flow Controllers (MFCs) in 4 ranges (FS): 0.5\/2\/5\/20 l\u003csmall\u003en\u003c\/small\u003e\/min (based on N\u003csmall\u003e2\u003c\/small\u003e), turndown 1:500, flow + temperature + pressure\u003c\/li\u003e\n\u003cli\u003ePreconfigured Standard (PS), MFCs in 4 ranges (FS): 0.5\/2\/5\/20 l\u003csmall\u003en\u003c\/small\u003e\/min (based on N\u003csmall\u003e2\u003c\/small\u003e), turndown 1:50, flow + temperature\u003c\/li\u003e\n\u003cli\u003eBuilt-to-Order (BtO), MFCs and Mass Flow Meters (MFMs), free selection of ranges between 0.5 and 20 l\u003csmall\u003en\u003c\/small\u003e\/min (FS, based on N\u003csmall\u003e2\u003c\/small\u003e), turndown 1:1000; including multi-channel versions up to 8 channels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878384328835,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/flexi-flow-bronkhorst-flow-controller-low-flow-meter-benchtop-equipment-for-bioreactors.png?v=1763385664"},{"product_id":"low-flow-control-valve","title":"Low Flow Control Valve","description":"\u003cp\u003eControl valves can be furnished as an integral part of a mass \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/flow-instrumentation\" title=\"Flow Meters and Controllers\"\u003eflow controller\u003c\/a\u003e, a pressure controller, or as a separate component in combination with a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\" title=\"Gas Flow Meters\"\u003egas flow\u003c\/a\u003e meter, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/liquid-flow-meters-and-controllers\" title=\"Liquid Flow Meters\"\u003eliquid flow\u003c\/a\u003e meter, or a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/pressure-meters\" title=\"Low Flow Pressure Meters\"\u003epressure meter\u003c\/a\u003e. The proportional, electromagnetic control valves, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/bronkhorst\" title=\"Bronkhorst Low Flow Instrumentation\"\u003eBronkhorst\u003c\/a\u003e, feature fast and smooth control characteristics. With reference to the specific fields of application there are different series of unique control valves options.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect acting valves\u003c\/li\u003e\n\u003cli\u003eVary-P valves\u003c\/li\u003e\n\u003cli\u003ePilot-operated valves\u003c\/li\u003e\n\u003cli\u003ePressure compensated bellow valves\u003c\/li\u003e\n\u003cli\u003eLiquid flow valves\u003c\/li\u003e\n\u003cli\u003eManual control valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eLow Flow Control Valve for Gases\u003c\/h2\u003e\n\u003cp\u003eFlow control valves F-001 \/ F-011 are suitable for low flow rates (up to approximately 65 l\u003csmall\u003en\u003c\/small\u003e\/min) with pressure ratings up to 100 bar. The F-001 valve module is also used as a pilot valve in bigger valves and controllers. F-021 is a direct acting control valve for high pressure applications up to 200 bar.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eF-001: flow up to 65 l\u003csmall\u003en\u003c\/small\u003e\/min; pressure up to 64 bar; Kv-max of 6.6 x 10\u003csup\u003e-2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eF-011: flow up to 65 l\u003csmall\u003en\u003c\/small\u003e\/min; pressure up to 100 bar; Kv-max of 6.6 x 10\u003csup\u003e-2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eF-021: flow up to 70 l\u003csmall\u003en\u003c\/small\u003e\/min; pressure up to 200 bar; Kv-max of 1.56 x 10\u003csup\u003e-3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHigh Pressure Flow Control Valve for Gases\u003c\/h2\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Low-Flow-Control-Valve-Bronkhorst-Flowmeter-Controller-Liquid-Flow-Gas-Flow-Measurement-Automation-Controls-Process-Solutions-Corp-PSC-Texas.jpg?v=1771876483\" alt=\"Low-Flow-Control-Valve-Bronkhorst-Flowmeter-Controller-Liquid-Flow-Gas-Flow-Measurement-Automation-Controls-Process-Solutions-Corp-PSC-Texas\" style=\"margin-left: 25px; float: right;\" width=\"500\" height=\"521\"\u003e\u003c\/div\u003e\n\u003cp\u003eF-033 \/ F-042 2-phase flow control valve for applications with high differential pressures and a maximum operating pressure of up to 700 bar. These unique valves feature a pressure compensation mechanism, thus maintaining a constant pressure difference of 4 bar across the flow control section. As a result, both the inlet pressure and the outlet pressure may change without having any impact on the Vary-P valve function.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eF-033: flow up to 100 l\u003csmall\u003en\u003c\/small\u003e\/min; pressure up to 400 bar\u003c\/li\u003e\n\u003cli\u003eF-042: flow up to 100 l\u003csmall\u003en\u003c\/small\u003e\/min; pressure up to 700 bar\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eControl Valves for Low Pressure Drop Applications\u003c\/h2\u003e\n\u003cp\u003eThese are direct acting control valves similar to the F-001 series. They are closed by spring force and a bellows compensates the closing force acting on the plunger to such a degree that only a very small magnetic force is necessary. In this way, large orifices can be open, which is impossible in the F-001 design as it would cause oscillation. The bellows pressure compensated design, however, enables users to smoothly control large flows at extremely low pressures.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eF-004A: flow up to 400 l\u003csmall\u003en\u003c\/small\u003e\/min; Kv of 0.03 to 0.3\u003c\/li\u003e\n\u003cli\u003eF-004B: flow up to 1,300 l\u003csmall\u003en\u003c\/small\u003e\/min; Kv of 0.1 to 1.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eLiquid Flow Control Valves (Direct Acting Valves)\u003c\/h2\u003e\n\u003cp\u003eBronkhorst \u003ca title=\"Liquid Flow Meters and Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/liquid-flow-meters-and-controllers\"\u003eliquid flow\u003c\/a\u003e meters can connect to a control valve to form a closed control loop. The standard direct acting valve, model C2I, is normally closed, has a pressure capability of 100 bar (1500 PSI) as well as a purge connection for easy elimination of air or gas. Model C5I is ideal for liquid flow applications with higher flow rates and pressure rating up to 100 bar, however, this control valve may also be used for gas flow applications. C2I and C5I control valves directly operate via a magnetic coil with \u003ca title=\"IP Ratings in Industrial Instrumentation\" href=\"https:\/\/www.iec.ch\/ip-ratings\" rel=\"noopener\" target=\"_blank\"\u003eIP65\u003c\/a\u003e (weatherproof) housing and are closed when de-energized (Normally Closed). Depending on flow rate and fluid, these liquid flow control valves allow a pressure drop of maximum 5 to 40 bar (d).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC2I: pressure up to 100 bar; Kv-max of 2.37 x 10\u003csup\u003e-3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eC5I: pressure up to 100 bar; Kv-max of 6.6 x 10\u003csup\u003e-2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFLOW-CONTROL Series - Manual Control Valves with Pressure Compensation\u003c\/h2\u003e\n\u003cp\u003eThe new FLOW-CONTROL Series are manual control valves for extremely precise control of a constant flow rate in low flow gas and liquid applications. The desired flow rate is set via the needle valve. Any upstream or discharge pressure variations are automatically compensated by a built-in membrane operated valve to ensure a steady, constant flow. Thanks to its clever design and construction, these instrument models do not require any electrical power source. The manual constant-flow control series is available in 4 different models to control flow capacities in a range from for gas of up to 50 l\u003csmall\u003en\u003c\/small\u003e\/min and 3 models with up to 1.8 l\/min. While process connections are optionally available, the in-line valve assemblies feature G 1\/4 BSPP female inlet and outlet ports.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas flow up to 50 l\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e\n\u003cli\u003eLiquid flow up to 1.8 l\/min\u003c\/li\u003e\n\u003cli\u003eOperating pressure up to 10 bar(g)\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"IP Ratings for Industrial Instrumentation\" href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\"\u003eIP65 ingress protection\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFLOW-ADJUST Manual Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe new FLOW-ADJUST manual control valves offer extremely precise control in low flow gas and liquid applications. These manual control valves are available in 2 standard resolution (SR) options and 5 high resolution (HR) models, each offering smooth control of gas or liquid flow. The standard resolution needle valves cover the two highest flow ranges whereas the high resolution valves cover the lower gas and liquid flow ranges.\u003c\/p\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878390882435,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/low-flow-control-valves-bronkhorst-flow-controller-liquid-flows-gas-streams-psc-texas-oklahoma-louisiana.png?v=1763385909"},{"product_id":"in-line-filters-for-gas","title":"IN-LINE Filters for Gas","description":"\u003cul\u003e \u003cli\u003eFilters for \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\/\"\u003eMass Flow Meters and Controllers\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eFor increasing the MTBF (Mean Time Between Failure)\u003c\/li\u003e \u003cli\u003econtains a 316L sintered metal filter cartridge\u003c\/li\u003e \u003cli\u003eHousing: AISI 316\u003c\/li\u003e \u003cli\u003eO-rings: Viton; optional EPDM and FFKM (Kalrez)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIN-LINE Filters Selection\u003c\/h3\u003e Choose low-flow or medium-flow style IN-LINE filters for instruments with 1\/4â female thread at the inlet. The high-flow filter is suitable for mounting into instruments with 1\/2â female thread. The ultra-low-flow filters have 1\/8\" connections. In principle, select finest porosity with low ÎP. Preferably, ÎP is not higher than 250 to 500 mbar, and porosity is not bigger than 5 Î¼m. The ÎP across the IN-LINE filter can be calculated with the help of our online calculation tool FLUIDAT. \u003ch3\u003eBronkhorst IN-LINE Filters Dimensions\u003c\/h3\u003e [caption id=\"attachment_21195\" align=\"aligncenter\" width=\"750\"]\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/in-line-filters-dimensions-bronkhorst-flow-instrumentation-distributor-online-near-me-psc-texas.jpg\"\u003e\u003cimg class=\"wp-image-21195 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/in-line-filters-dimensions-bronkhorst-flow-instrumentation-distributor-online-near-me-psc-texas.jpg\" alt=\"in-line-filters-dimensions-bronkhorst-flow-instrumentation-distributor-online-near-me-psc-texas\" width=\"750\" height=\"268\"\u003e\u003c\/a\u003e \u003ccenter\u003eDimensions in mm\u003c\/center\u003e[\/caption] \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eModel\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eA\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eB\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eC\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eD\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eG\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eSpan 1\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eSpan 2\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-410\/M-420 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 53 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 89 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 10 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã¸ 24 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1\/8\" \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-411\/M-421 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 53 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 91 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 10 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã¸ 24 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4\" \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-412\/M-422 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 70 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 106 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 10 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã¸ 35 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4\" \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 30 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 32 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413\/M-423 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 80 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 129 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 14 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã¸ 35 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2\" \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 30 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 32 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003ePressure Drop\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The approximate pressure drop across a filter assembly can be calculated as follows: \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eStylett\u003c\/th\u003e \u003cth\u003eModel no.\u003c\/th\u003e \u003cth\u003eAverage porosity\u003c\/th\u003e \u003cth\u003eType \/ area\u003c\/th\u003e \u003cth\u003eConnections in \/ out\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ultra-low-flow \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-410-13\/M-420-13 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.5 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1\/8â female \/ 1\/8â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-410-16\/M-420-16 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1\/8â female \/ 1\/8â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-410-18\/M-420-18 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 7 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1\/8â female \/ 1\/8â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-410-20\/M-420-20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 15 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1\/8â female \/ 1\/8â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Low-flow \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-411-13\/M-421-13 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.5 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-411-16\/M-421-16 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-411-18\/M-421-18 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 7 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-411-20\/M-421-20 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 15 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 2.5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Medium-flow \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-412-16\/M-422-16 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-412-17\/M-422-17 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 5 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-412-19\/M-422-19 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 10 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-412-21\/M-422-21 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â4â female \/ 1â4â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e High-flow \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413-16\/M-423-16 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2â female \/ 1â2â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413-17\/M-423-17 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 5 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2â female \/ 1â2â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413-19\/M-423-19 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 10 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2â female \/ 1â2â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413-21\/M-423-21 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 20 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2â female \/ 1â2â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e M-413-22\/M-423-22 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 40 Î¼m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 316L \/ 5 cm2 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1â2â female \/ 1â2â male \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eExample\u003c\/h3\u003e Flow 80 l\u003csmall\u003en\u003c\/small\u003e\/min air, pressure 5 bara, filter selected: M-422-17 (5 Î¼m). At P1 = 1 bara, âP across filter = 389 mbar (see second graph on the next page). At P1 = 5 bara, âP = 389 = 78 mbar. 5 For other gases than air the pressure drop is difficult to calculate, because the total pressure drop is built up from both laminar and turbulent pressure losses. Therefore, use the Filter Calculations routine on \u003ca href=\"https:\/\/www.fluidat.com\/default.asp\" target=\"_blank\" rel=\"noopener\"\u003eFluidat\u003c\/a\u003e or contact us regarding exact pressure losses, if so required. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878390947971,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/IN-LINE-Filters-bronkhorst-flow-instrumentation-gas-flow-meter-thermal-mass-flow-instrumentation-distributor-psc-texas-oklahoma-houston.jpg?v=1763385911"},{"product_id":"gas-mixing-chamber","title":"Gas Mixing Chamber","description":"\u003cp\u003eOur Gas Mixing Chambers enable precision creation of \u003ca href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\" title=\"Gas Mixing Chambers for Homogeneous Gas Mixtures\" target=\"_blank\"\u003ehomogeneous gas mixtures\u003c\/a\u003e essential for analytical, laboratory, and industrial applications. Unlike simple gas blending, producing a true homogeneous mixture requires specially designed chambers to thoroughly mix individual flows with minimal turbulence and maximum repeatability. This is especially true when combining significantly different flow rates such as low-dosing gas with a high-volume carrier.\u003c\/p\u003e\n\u003cp\u003eOur gas mixing chambers, from \u003ca title=\"Bronkhorst Low Flow Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/bronkhorst\"\u003eBronkhorst\u003c\/a\u003e, integrate seamlessly with mass \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Meters and Controllers\"\u003eflow meters and controllers\u003c\/a\u003e, thus ensuring accurate, consistent composition from trace levels up to practical process flows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eflow ranges from 300 ml\u003csmall\u003en\u003c\/small\u003e\/min up to 10,000 ml\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e\n\u003cli\u003efor creating homogeneous gas mixtures from percentages down to ppm ranges\u003c\/li\u003e\n\u003cli\u003eavailable with 1\/4\" or 6 mm connections\u003c\/li\u003e\n\u003cli\u003epressure rating up to 20 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eGas Mixing Chambers for Blending Your Own Homogenous Gas Mixtures\u003c\/h2\u003e\n\u003cp\u003eOur gas mixing chambers are ideal for use in calibration gas generation, environmental and surface treatment systems, process control loops, or any setup demanding stable mixed gas streams. These gas mixing chambers help eliminate compositional gradients, thus improving measurement reliability and performance quality. Robustly constructed for compatibility with a wide range of gases, Bronkhorst gas mixing chambers support flexible system design while enhancing uniform blending without compromising flow integrity.\u003c\/p\u003e\n\u003cp\u003eTheir compact footprint allows easy installation into existing gas delivery systems, and our technical support team and engineers can assist in selecting optimal configurations tailored to specific flow ranges and applications. Unlock greater precision with our gas mixing solutions, your foundation for consistent, homogeneous gas blends in critical applications.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas.jpg?v=1771512477\" alt=\"Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"1\/4\" OD Compression","offer_id":46603716100227,"sku":"7.01.188","price":665.0,"currency_code":"USD","in_stock":true},{"title":"6 mm OD Compression","offer_id":46603716132995,"sku":"7.01.446","price":665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Gas-Mixing-Chamber_bronkhorst-flow-instrumentation-meters-flow-controllers-shop-online-process-solutions.png?v=1763385913"},{"product_id":"gas-mixing-systems","title":"Gas Mixing Systems","description":"\u003cp\u003eFor many processes, very accurate compositions of gas are necessary, which means simply adding two or more gas streams together isn't sufficient. Homogeneous gas mixing systems enable operators to create accurate and \u003ca rel=\"noopener\" title=\"Gas Mixing Chambers for Homogeneous Gas Mixtures\" href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\" target=\"_blank\"\u003eprecise gas compositions\u003c\/a\u003e of two or more gases. Our gas mixers offer a repeatable and reliable process that helps eliminate discrepancies. They also ensure that operators have access to the exact gas compositions their processes require at any time. Mixing your own gas increases process efficiency and reduces the cost of having to purchase premixed gas cylinders.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecreate homogeneous gas mixtures from percentages down to ppm-ranges\u003c\/li\u003e\n\u003cli\u003ehigh accuracy and repeatability with a fast response\u003c\/li\u003e\n\u003cli\u003eflow ranges from 300 ml\u003csmall\u003en\u003c\/small\u003e\/min up to 10,000 ml\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e\n\u003cli\u003epressure rating up to 100 bar\u003c\/li\u003e\n\u003cli\u003eavailable with 1\/4\" or 6 mm connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHomogeneous Gas Mixing Systems\u003c\/h2\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas.jpg?v=1771512477\" alt=\"Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas\" style=\"margin-left: 25px; float: right;\" width=\"501\" height=\"247\"\u003e\u003c\/div\u003e\n\u003cp\u003eUp to 12 \u003ca href=\"https:\/\/www.psctexas.shop\/products\/gas-cylinder-monitoring-system-gcm\" title=\"Gas Cylinder Monitoring System\"\u003egas cylinders\u003c\/a\u003e can connect to an equal amount of mass flow controllers. With accurate control, the gas flows enter a \u003ca href=\"https:\/\/www.psctexas.shop\/products\/gas-mixing-chamber\" title=\"Bronkhorst Gas Mixing Chamber\"\u003egas mixing chamber\u003c\/a\u003e where it becomes a homogeneous mixture. Then, it can flow directly to instrumentation, such as gas chromatographs. \u003ca href=\"https:\/\/www.iso.org\/standard\/45471.html\" rel=\"nofollow noopener\" title=\"ISO Standards\" target=\"_blank\"\u003eISO 6145-7:2009\u003c\/a\u003e describes a procedure to prepare calibration gas mixtures using commercially available \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/thermal-flow-meters\" title=\"Thermal Mass Flow Meters\"\u003ethermal mass flow\u003c\/a\u003e controllers. Calculation of the accuracy of the final gas composition that leaves the gas mixing system occurs through special software. The software considers the uncertainties in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\" title=\"Gas Flow Meters and Controllers\"\u003egas flows\u003c\/a\u003e and the gas composition of the initial gas cylinders.\u003c\/p\u003e\n\u003cp\u003eWhen comparing the purchase of gas cylinders with premixed gas mixtures, the preparation of gas mixtures on-site has some advantages. For example, the lifetime of premixed gas mixtures can be limited and expired gas can be costly. Furthermore, emergency gas deliveries and down-time due to not having necessary gas blends can be a huge problem. The costs for these gas cylinders can be quite high. And you can't always be sure that the concentration of the gas is still good, accurate, or that the mixture is still homogeneous. \u003c\/p\u003e\n\u003cp\u003eTherefore, it can be beneficial for users to prepare gas mixtures on their own with very low concentrations of specific compounds. As an operator, you'll no longer need to invest in cylinders of premixed gas cylinders. And it gives a lot of flexibility and freedom to calibrate an analyzer in your own time. Overall, our homogeneous gas mixing systems provide great value through high accuracy and flexibility as well as seamless, user-friendly controls, and powerful capabilities via \u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" title=\"Modbus Protocol\" target=\"_blank\"\u003eModbus\u003c\/a\u003e protocol.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHow to Create Custom Gas Mixtures\u003c\/h2\u003e\n\u003cp\u003eThere is more to creating gas mixtures than simply combining two gas streams into one. For example, if you need to dilute 1 ml\u003csmall\u003en\u003c\/small\u003e\/min of dopant with 10 l\u003csmall\u003en\u003c\/small\u003e\/min of dilution gas, you cannot expect to obtain a homogeneous mixture unless an appropriate mixing chamber is used. Luckily, our homogenous gas mixing systems offer precision in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Instrumentation\"\u003elow flow\u003c\/a\u003e gas mixing applications.\u003c\/p\u003e\n\u003cp\u003eA user-friendly, touchscreen \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-control\" title=\"Automation Controllers\"\u003econtrols interface\u003c\/a\u003e allows users to easily input the composition of the desired gas mixture. Gas then automatically flows from gas cylinders and into a gas mixing chamber using gas flow meters and controllers. There, gas mixes homogeneously to quickly become ready for direct use in processes or it can undergo compression for later use. The process is both accurate and repeatable and users of any experience level can operate our gas mixing systems. With our system it's simple to blend your own high purity, homogenous gas streams on site.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Uses of a In-House Gas Mixing System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaboratory and Research Universities\n\u003cul\u003e\n\u003cli\u003emixing reference gas for analyzers\u003c\/li\u003e\n\u003cli\u003efor use in gas chromatography\u003c\/li\u003e\n\u003cli\u003egeneration of reference or calibration gases\u003c\/li\u003e\n\u003cli\u003eenvironmental testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and Beverage Production\n\u003cul\u003e\n\u003cli\u003efermentation of beer\u003c\/li\u003e\n\u003cli\u003ebioreactor applications for oxygen and CO\u003csmall\u003e2\u003c\/small\u003e control\u003c\/li\u003e\n\u003cli\u003ecell culture incubation\u003c\/li\u003e\n\u003cli\u003euse in sterile production environments\u003c\/li\u003e\n\u003cli\u003eextending shelf-life and freshness preservation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSemiconductor and Electronics Manufacturing\n\u003cul\u003e\n\u003cli\u003eplasma etching\u003c\/li\u003e\n\u003cli\u003eoxidation\u003c\/li\u003e\n\u003cli\u003edoping processes\u003c\/li\u003e\n\u003cli\u003echemical vapor deposition (CVD) processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOil and Energy\n\u003cul\u003e\n\u003cli\u003enatural gas blending\u003c\/li\u003e\n\u003cli\u003eflare gas simulation\u003c\/li\u003e\n\u003cli\u003eprocess optimization \u003c\/li\u003e\n\u003cli\u003esafety systems testing\u003c\/li\u003e\n\u003cli\u003ehydrogen blending research\u003c\/li\u003e\n\u003cli\u003efuel cell testing\u003c\/li\u003e\n\u003cli\u003epower generation combustion control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAerospace, Aviation, and Automobiles\n\u003cul\u003e\n\u003cli\u003eemissions testing\u003c\/li\u003e\n\u003cli\u003eengine combustion research\u003c\/li\u003e\n\u003cli\u003eenvironmental simulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878400680067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Homogenous-Gas-Mixing-Systems-Bronkhorst-Low-Flow-Meters-Gas-Mixing-Chamber-Reference-Gas-Generation-Calibration-Gas-Chromatography-Bioreactor-Oxidation-Control-Process-Solutions-Corp.png?v=1771519548"},{"product_id":"classic-810-threaded-thermal-flow-sensor","title":"CLASSIC 810 Threaded Thermal Flow Sensor","description":"The Kayden CLASSIC 810 thermal flow, level, and interface switch and transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, it is available in a wide range of thread sizes and insertion lengths. All models also feature a rugged flameproof enclosure with blind or lens cover options. The CLASSIC 810, from \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e, has advanced digital electronics that will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA Analog Output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 810 Thermal Flow Meter, Level Switch, Interface Measurement\u003c\/h3\u003e \u003ch5 style=\"text-align: left;\"\u003eProcess Connections - MNPT\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1\/2 inches\u003c\/li\u003e \u003cli\u003e3\/4 inches\u003c\/li\u003e \u003cli\u003e1.0 inches\u003c\/li\u003e \u003cli\u003e1 1\/4 inches\u003c\/li\u003e \u003cli\u003e1 1\/2 inches\u003c\/li\u003e \u003cli\u003e2 inches\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1.2 inches (3.0 cm)\u003c\/li\u003e \u003cli\u003e2 inches (5.0 cm)\u003c\/li\u003e \u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e \u003cli\u003e4 inches (10.1 cm)\u003c\/li\u003e \u003cli\u003e6 inches (15.2 cm)\u003c\/li\u003e \u003cli\u003e9 inches (22.8 cm)\u003c\/li\u003e \u003cli\u003e12 inches (30.4 cm)\u003c\/li\u003e \u003cli\u003e18 inches (45.7 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available from 2.5 inches (6.0 cm) to 120 inches (305 cm) by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 810\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 Vdc\u003c\/li\u003e \u003cli\u003e120-240 Vac\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eCSA \u0026amp; FM: 3480 psi, 24000 kPa, 240 bar\u003c\/li\u003e \u003cli\u003eCRN (316\/316L Stainless Steel) - Canadian Registration\u003c\/li\u003e \u003cli\u003eNumber 0F22124.2C: 1990 psi, 13721 kPa, 137.2 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for Kayden CLASSIC 810 Thermal Flow, Level, Interface\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003ehigh pressure thermal flow meter\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eThermal Flow Meter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel Switch and Detection\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface Measurement\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421454979,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-810-Threaded-Flow-Meter-Level-Switch-Interface-Temperature-Thermal-Sensor-Process-Solutions-Corp.png?v=1763386416"},{"product_id":"classic-812-flow-level-switch-flanged","title":"CLASSIC 812 Flow, Level Switch (Flanged)","description":"The CLASSIC 812 Flow, Level Switch and Transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the CLASSIC 812 is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings, and insertion lengths. All \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 812 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eper flange rating, ASME B16.5\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eother materials available\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the CLASSIC 812\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, level switch \u0026amp; interface\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421487747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-812-Flanged-Switch-and-Transmitter-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-PSC-Texas.png?v=1763386417"},{"product_id":"classic-814-flanged-retractable-packing-gland","title":"CLASSIC 814, Flanged Retractable Packing Gland","description":"The CLASSIC 814 Flow, Level, and Interface Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 814 Retractable Packing Gland is available with a Raised Face or RTJ Flange, in a wide range of flange sizes and ANSI ratings, with low and medium pressure applications. All Kayden models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23827 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\" alt=\"Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas\" width=\"1000\" height=\"380\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eretractable packing gland\u003c\/li\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edependent on flange rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-40 to 320ËF (-40 to 160ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind c0ver or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 814 Flanged, Retractable Packing Gland\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 814 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421520515,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-switch-interface-sensing-process-solutions-texas.png?v=1763386418"},{"product_id":"classic-816-threaded-retractable-packing-gland","title":"CLASSIC 816, Threaded Retractable Packing Gland","description":"The CLASSIC 816 Flow, Interface, and Level Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the CLASSIC 816 Threaded Retractable Packing Gland is available in a wide range of insertion lengths, with low and medium pressure applications. All \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23832 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp.jpg\" alt=\"Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp\" width=\"1000\" height=\"395\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 816 Flow, Interface, Level Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections - MNPT\u003c\/h5\u003e \u003cul\u003e \u003cli\u003ethreaded retractable packing gland (1\" MNPT)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the Kayden CLASSIC 816 Interface, Flow, and Level Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edetermined by retractable packing gland rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-40 to 320ËF (-40 to 160ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 816 Interface, Flow, and Level Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 816 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421553283,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Texas.png?v=1763386419"},{"product_id":"classic-830-threaded-in-line-flow-level","title":"CLASSIC 830, Threaded In-Line Flow, Level","description":"The CLASSIC 830 Threaded, In-Line Flow Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes and is available with 3\/4\" FNPT connections in a horizontal or vertical orientation. In addition, all \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 830 Threaded In-Line Flow Transmitter and Switch\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3\/4\" FNPT\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 20,000 cc\/second\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Assembly Body Length\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3.5 inches (8.8 cm)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Mounting Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003ehorizontal\u003c\/li\u003e \u003cli\u003evertical\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput Power for the Kayden CLASSIC 830 In-Line Flow Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3,480 psi\u003c\/li\u003e \u003cli\u003e24,000 kPa\u003c\/li\u003e \u003cli\u003e240 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPTÂ conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e with nickel braze\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 830 for In-Line Flow Measurement and Control\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-In-Line-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 830 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421586051,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-830-Threaded-In-Line-Flow-Meter-level-switch-interface-senor-process-solutions-corp.png?v=1763386420"},{"product_id":"classic-832-flanged-in-line-flow-switch","title":"CLASSIC 832, Flanged In-Line Flow Switch","description":"The CLASSIC 832 Flanged, In-Line Flow Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes and is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings and assembly widths. In addition, all \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 832 Flanged In-Line Flow Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 20,000 cc\/second\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Assembly Body Width\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 7 inches (18 cm) to maximum 72 inches (182 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003cli\u003eminimum width varies with flange size and rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput Power for the Kayden CLASSIC 832 In-Line Flow Transmitter and Switch\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3,480 psi\u003c\/li\u003e \u003cli\u003e24,000 kPa\u003c\/li\u003e \u003cli\u003e240 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e with nickel braze\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 832 Flow Switch for In-Line Flow Control andÂ Measurement\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eFM\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-In-Line-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Flow-Switch-Pipeline-Gas-Processing-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflow switch for pump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 832 Flow Switch and Level Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421618819,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-832-Flanged-In-Line-Flow-Switch-Level-gas-processing-Transmitter-Interface-Media-Process-Solutions-Corp.png?v=1763386421"},{"product_id":"master-touch-series-8600-8700mpnh-gen-inline-flow-meters","title":"Master-Touch Series 8600-8700MPNH GEN Inline Flow Meters","description":"\u003cp\u003eMaster-Touch Series 8600-8700MPNH GEN Inline Flow Meters are rugged, cleanable, thermal mass flow sensors. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors feature construction of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then receive a thin glass coating.\u003c\/p\u003e\n\u003cp\u003eThe assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit.\u003c\/p\u003e\n\u003cp\u003eThe second sensor undergoes self-heating, using a temperature sensor and bridge circuitry, to a constant temperature above that of the gas stream. The bridge maintains overheat temperature and counterbalances the temperature effects through Eldridge Product Inc.'s (EPI) proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ±  50% of factory calibration pressure\u003c\/li\u003e\n\u003cli\u003ecertifications: CE, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\" title=\"CSA Group\"\u003eCSA\/CUS\u003c\/a\u003e - Class 2252-03 \u0026amp; 2252-83, CSA Enclosures Type 4X, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP66\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eMaster-Touch 8600-8700 Series Flow Meters\u003c\/h2\u003e\n\u003cp\u003eMaster-Touch inline style thermal mass flow meters include a flow section that matches the user’s flow conduit and then plumbs directly into the process line. The sensing elements mount directly in the flow section for exposure to the process gas. The inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 4\" pipe or tube. They feature a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as per application requirement.\u003c\/p\u003e\n\u003cp\u003ePipe sizes more than 4\" typically require insertion style thermal mass flow meters. Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers ratings for non-hazardous environments. Furthermore, the enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eThermal Mass Flow Meters for Gases\u003c\/h2\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-match, reference-grade platinum Resistance Temperature Detectors (RTDs). In addition, the platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and are insensitive to pressure changes, so the output signal is a true mass flow rate signal.  \u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878425944195,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Eldridge-Products-Master-Touch-Series-8600-8700MPNH-GEN-Inline-Aeration-Flow-Meters-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.png?v=1763386473"},{"product_id":"insertion-flow-meters-master-touch-series-8800mp-haz","title":"Insertion Flow Meters, Master-Touch Series 8800MP HAZ","description":"Our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003einsertion flow meters\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI\u003c\/a\u003e, provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter is calibrated using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± (1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eThermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eMaster-Touch Series 8800MP HAZ Insertion Flow Meters\u003c\/a\u003e include a rugged and cleanable thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. This maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream from control by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003eMaster-Touch 8800 Series Insertion Flow Meters for Hazardous Locations\u003c\/h3\u003e Insertion style thermal mass flow meters include a sensor and probe assembly that is inserted into the process gas flow conduit to allow the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. The tube length must be specified upon ordering. For other probe diameters and lengths, please consult the factory. Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/inline-flow-meters\/\"\u003einline flow section\u003c\/a\u003e or to the \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003einsertion probe assembly\u003c\/a\u003e at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display\/keypad assembly. \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eThermal Mass Flow Insertion Flow Meters\u003c\/a\u003e Operation Principle\u003c\/h3\u003e Thermal mass insertion flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matching, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller uses smart sensor technology to preferentially heat one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase relates directly to the gas molecular rate of flow. Our sensors are also temperature compensated for a wide process gas temperature range. In addition, they are insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8800 MP HAZ\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/11\/EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26268 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/11\/EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas.jpg\" alt=\"EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch5\u003eCertifications\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eKOSHA\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eT2\u003c\/li\u003e \u003cli\u003eT3\u003c\/li\u003e \u003cli\u003eT4\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eProbe Selection\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 1\/2\", 3\/4\", 1\"\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6 to 60\" (depending on width)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878425976963,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Master-Touch-Series-8800-MP-HAZ-Insertion-Flow-Meter-for-Hazardous-Areas-EPI-Eldridge-Products-Inc-Process-Solutions-Corp.png?v=1763386473"},{"product_id":"master-touch-8200mp-haz-r-remote-transmitter-insertion","title":"Master-Touch 8200MP HAZ R, Remote Transmitter, Insertion","description":"The Master-Touch 8200MP HAZ R Series includes a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor with remote transmitter\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built upon the ceramic substrate and they receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream. The temperature sensor and bridge circuitry controls the heating process. Our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003e8200 Series Flow Meters with Remote Transmitter for Hazardous Locations\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eInsertion style thermal mass flow meters\u003c\/a\u003e include a sensor and probe assembly that inserts into the process gas flow conduit. Â In doing this, it allows process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. Operators must indicate the tube length upon ordering. For other probe diameters and lengths, \u003ca href=\"mailto:sales@psctexas.com\"\u003eplease reach out for additional support\u003c\/a\u003e. Remote style thermal mass flow meters utilize two enclosures. First, an enclosure mounts at the point of measurement on the probe assembly. This enclosure offers ratings for hazardous environments. The second (remote) enclosure positions in a readily accessible location with non-hazardous conditions. \u003ca href=\"mailto:sales@psctexas.com\"\u003eContact us for information concerning remote explosion-proof enclosure\u003c\/a\u003e. The remote enclosure includes all the electrical connections as well as the linearizing electronics and the display\/keypad assembly. A 5-conductor shield cable is necessary to carry the flow signal between the two enclosures. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003eThermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003eThermal mass flow meters\u003c\/a\u003e use the principle of convective heat transfer to directly measure mass flow. \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPIâs\u003c\/a\u003e proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors temperature compensate for a wide process gas temperature range and are insensitive to pressure changes. Thus, the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch 8200MP HAZ R, Remote Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26291 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas\" width=\"1000\" height=\"502\"\u003e\u003c\/a\u003e \u003ch5\u003eCertifications\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eKOSHA\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eT2\u003c\/li\u003e \u003cli\u003eT3\u003c\/li\u003e \u003cli\u003eT4\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eDual Sided Explosion-Proof Enclosure For Hazardous Locations\u003c\/li\u003e \u003cli\u003e8\" X 10\" Ordinary Locations (Non-Explosion Proof)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eProbe Selection\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 1\/2\", 3\/4\", 1\"\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6 to 60\" (depending on width)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBall Valve Retractor\u003c\/strong\u003e: Optional\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426009731,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-Series-8200MP-HAZ-R-Remote-Insertion-Flow-Meters-Process-Solutions-Corp.png?v=1763386474"},{"product_id":"master-touch-averaging-flow-tube-9700mp-haz-fat","title":"Master-Touch Averaging Flow Tube, 9700MP HAZ FAT","description":"\u003cp\u003eMaster-Touch 9700MP HAZ FAT in-line averaging flow tube flow meters include a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors, from Eldridge Products Inc. (EPI), consist of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating.\u003c\/p\u003e\n\u003cp\u003eThe assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The flow tube sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas.\u003c\/p\u003e\n\u003cp\u003e This maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream from control by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e9700 MP Series Averaging Flow Tube Flow Meter for Hazardous Areas\u003c\/h2\u003e\n\u003cp\u003eInline style thermal mass flow meters include a flow section that meets the user’s flow conduit. Then it plumbs directly into the process line. The sensing elements of this design mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 4\" pipe or tube. Furthermore, they feature a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc.\u003c\/p\u003e\n\u003cp\u003ePipe sizes more than 4\" typically require insertion style thermal mass flow meters. Integral style flow tube thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers ratings for hazardous environments. The enclosure mounts directly to the inline flow section at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003eOur patented Flow Averaging Tube (FAT) designs use the principle of convective heat transfer to directly measure mass flow. Moreover, they are ideal for most applications with limited available straight run. In many installations, the up-stream straight run can reduce to three diameters. The probe has several large diameter inlet ports along the length of the upstream impact surface.\u003c\/p\u003e\n\u003cp\u003eThe pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas returns to the main flow stream through the ports near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still require some minor adjustment to achieve the best accuracy.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 9700 MP HAZ FAT\u003c\/h2\u003e\n\u003ch4\u003eCertifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iecex.com\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApprovals\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeter Orientation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: horizontal, vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: left side, right side, above pipe, below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeter Housing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426042499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-Series-9700MP-HAZ-FAT-Inline-Flow-Tube-Flowmeter-Process-Solutions-Texas.png?v=1763386475"},{"product_id":"inline-flow-switch-epi-series-7000","title":"Inline Flow Switch, EPI Series 7000","description":"The enclosure for the Series 7000 \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow switch\u003c\/a\u003e offers a rating for use in hazardous locations with T2, T3, and T4 approvals and it is available in domestic and international markets. The diecast aluminum, \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Type 4X\u003c\/a\u003e watertight enclosure is both flame and explosion proof and features a corrosion resistant finish. \u003cul\u003e \u003cli\u003eapprovals: \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eUL\/CUL Class I, Division 1, Group B\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Types 4X\/7\/9\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX approval options\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003efinish: safety blue polyester powder-coat\u003c\/li\u003e \u003c\/ul\u003e The 7000 series flow switch includes a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream. The temperature sensor and bridge circuitry controls the heating process. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26308 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.jpg\" alt=\"EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas\" width=\"1000\" height=\"502\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3 style=\"text-align: left;\"\u003eEPI 7000 Series Inline Flow Switch\u003c\/h3\u003e The inline style thermal mass flow switch includes the flow sensing element, temperature sensing element, bridge amplifier\/signal output board, transmitter encloÂ­sure, and flow section. The flow section matches the userâs flow conduit and plumbs directly in the flow line. The sensing elements mount directly in the flow section for exposure to the process flow. Inline flow switches are available in sizes from 1\/4\" pipe through 4\" pipe and offer threaded male NPT ends as the standard mounting style. Optional end mounting styles are available, such as tube ends, tube end fittings, butt weld ends, flanged end configurations, etc. Pipe sizes more than 4\" typically require insertion style thermal mass flow switches. All of EPIâs flow switches have two single-pole, double-throw relays for Hi\/Hi, Lo\/Lo, and Hi\/Lo capability. The contact closure is 5 amps @ 24 VDC and 115 VAC. Two LEDs provide verification when the Hi or Lo alarm triggers. The standard configuration has 316 Stainless Steel wetted parts (Hastelloy \u0026amp; Monel are also available). This design provides a rugged, cleanable instrument that's suitable for use in applications where corrosion, abrasion, high pressure, or rough handling may occur. \u003ch3 style=\"text-align: left;\"\u003eThermal Mass Flow Switches Operating Principle\u003c\/h3\u003e Thermal mass flow switches use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is within a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Smart sensor technology operates the microcontroller which preferentially heats one RTD. Then, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, thus causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors also offer temperature compensation for a wide process gas temperature range. They are also insensitive to pressure changes, so the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426075267,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Eldridge-Products-Inc-7000-Inline-Mass-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.png?v=1763386476"},{"product_id":"valumass-series-400-val-inline-flow-meters","title":"ValuMass Series 400 VAL Inline Flow Meters","description":"The ValuMass Series 400 VAL \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/inline-flow-meters\/\"\u003einline flow meters\u003c\/a\u003e are rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensors\u003c\/a\u003e. Our VALGEN-RD flow meters consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors position upon a ceramic substrate and then they receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3 style=\"text-align: left;\"\u003eMunicipal and Industrial Inline Flow Meters with Thermal Mass Flow Sensors\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26318 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas.jpg\" alt=\"EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas\" width=\"1000\" height=\"500\"\u003e\u003c\/a\u003e Our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow meters\u003c\/a\u003e provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter is also calibrated using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eValuMass Series 400 VAL Inline Flow Meters\u003c\/h3\u003e These thermal mass flow inline flow meters include a flow section that matches the userâs flow conduit. It then plumbs directly into the process line. The sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2\" pipe. The 3.5\" long flow sections also have MNPT ends as standard for easy mounting in the process line. \u003ca href=\"mailto:sales@psctexas.com\"\u003eYou can contact us\u003c\/a\u003e to inquire about pipe sizes over 2\". Integral style thermal mass inline flow meters contain all the electrical components and connections within one enclosure. Furthermore, this enclosure offers a rating for hazardous environments. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display assembly. Each VAL Series 400 aluminum enclosure includes a powder-coat-painted die-cast base and lid with a seal. The ratings available for the enclosure are: \u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP66, NEMA 1, 2, 4, 4X\u003c\/a\u003e. \u003ch3 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI Thermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPIâs\u003c\/a\u003e proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference. First, the process gas flow dissipates heat from the first RTD. This causes an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature also compensated for a wide process gas temperature range and insensitive to pressure changes. Therefore, the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426108035,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-ValuMass-400-Series-Inline-Flow-Meter-VALGEN-RB-Thermal-Mass-Flow-Meters-Process-Solutions-Corp.png?v=1763386477"},{"product_id":"valumass-series-540-val-insertion-flow-meters","title":"ValuMass Series 540 VAL Insertion Flow Meters","description":"\u003cp\u003eThe ValuMass Series 540 is a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are upon a ceramic substrate and then receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance.\u003c\/p\u003e\n\u003cp\u003eThe sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge force the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eRugged Flow Meters for Gases\u003c\/h4\u003e\n\u003cp\u003e Our ValuMass flow meters, from Eldridge Products Inc. (EPI), provide accurate, consistent, and rapid real-time flow measurement. Furthermore, the sensor is both temperature and pressure corrective. Each flow meter also undergoes calibration using standards traceable to the National Institute of Standards and Technology (\u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" title=\"National Institute of Standards and Technology\" rel=\"noopener\"\u003eNIST\u003c\/a\u003e).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eValuMass 540 Series Flow Meters\u003c\/h2\u003e\n\u003cp\u003eInsertion style thermal mass flow meters include a sensor \u0026amp; probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\" OD probes in 6\" to 36\" lengths as well as 3\/4\" probes to 60\" lengths. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options.\u003c\/p\u003e\n\u003cp\u003eUsers must specify the tube length upon ordering. Integral style ValuMass thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure also offers a rating for non-hazardous environments. The enclosure mounts directly to the insertion probe assembly at the point of measurement. It includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eEPI Thermal Mass Flow Meters\u003c\/h2\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD. This causes an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are also temperature compensated for a wide process gas temperature range. This makes them insensitive to pressure changes, so the output signal is a true mass flow rate signal.\u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426140803,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/ValuMass-Series-540-VAL-Eldridge-Products-Inc-EPI-Thermal-Mass-Flow-Meter-Insertion-Flow-Meter-Process-Solutions-Texas.png?v=1763386478"},{"product_id":"master-touch-series-8200mpnh-gen-remote-insertion-flow-meter","title":"Master-Touch Series 8200MPNH GEN Remote Insertion Flow Meter","description":"Master-Touch \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow meters\u003c\/a\u003eÂ provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eFlow Meters for Industrial Flow Measurement and Municipal Flow Metering\u003c\/a\u003e\u003c\/h3\u003e The Master-Touch 8200MPNH Gen Series, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI\u003c\/a\u003e, includes rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensors\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. Master-Touch GEN Series thermal mass flow meter enclosures offer ratings for use in ordinary locations. Furthermore, they are applicable in wet and dusty environments and are corrosion resistant. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26337 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.jpg\" alt=\"EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp\" width=\"1000\" height=\"500\"\u003e\u003c\/a\u003e \u003cul\u003e \u003cli\u003etransparent cover with four non-metallic corner screws\u003c\/li\u003e \u003cli\u003emaintenance free as well as corrosion resistant\u003c\/li\u003e \u003cli\u003eknockouts in the base facilitate conduit entry\u003c\/li\u003e \u003cli\u003econtinuous gaskets made of polyurethane foam guarantee optimal integrity\u003c\/li\u003e \u003c\/ul\u003e The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. This maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3 style=\"text-align: left;\"\u003eMaster-Touch 8200 Series Flow Meters for Non-hazardous Use\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eInsertion style thermal mass flow meters\u003c\/a\u003e include a sensor \u0026amp; probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. Users must specify the tube length upon ordering. \u003ca href=\"mailto:sales@psctexas.com\"\u003ePlease contact us\u003c\/a\u003e for other probe diameters and lengths. Master-Touch remote style thermal mass flow meters utilize two enclosures. One enclosure mounts at the point of measurement on the flow section. This enclosure also offers a rating for non-hazardous environments. Then, the second (remote) enclosure is usually in a readily accessible location with rating for non-hazardous conditions. The remote enclosure includes all the electrical connections as well as the linearizing electronics. Furthermore, it features the display \/ keypad assembly. A 5-conductor shielded cable is necessary to carry the flow signal between the two enclosures. \u003ch3\u003eMaster-Touch Rugged Thermal Mass Flow Meters\u003c\/h3\u003e Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then, the other RTD acts as the temperature reference. As a result, the process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range. They are insensitive to pressure changes, so the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426206339,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.png?v=1763386480"},{"product_id":"insertion-flow-meter-master-touch-9800mp-haz-fat","title":"Insertion Flow Meter, Master-Touch 9800MP HAZ FAT","description":"The Master-Touch 9800MP HAZ FAT \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/industrial-flow\/insertion-flow-meters\/\"\u003einsertion flow meter\u003c\/a\u003e is a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/flow-sensor\/thermal-mass-flow\/\"\u003ethermal mass flow meter\u003c\/a\u003e for gases. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built upon the ceramic substrate and then receive a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream and is controlled by the temperature sensor as well as the bridge circuitry. The bridge maintains the overheat temperature and also counterbalances the temperature effects through EPI's proprietary temperature compensation techniques. \u003cul\u003e \u003cli\u003eFeatures a certification for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous locations\u003c\/a\u003e (HAZ) with an explosionâproof enclosure, thus ensuring safe operation in classified environments.\u003c\/li\u003e \u003cli\u003eEmploys Flow Averaging Tube (FAT) technology to average multiple sensing points and deliver accurate \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003emass flow measurements\u003c\/a\u003e, even in short straightârun ducts.\u003c\/li\u003e \u003cli\u003eProvides direct mass flow output without the need for separate temperature or pressure compensation, thus simplifying system integration and control.\u003c\/li\u003e \u003cli\u003ePerfect for easy insertion style mounting into existing pipelines or ducts, which minimizes installation costs as well as downtime.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMaster-Touch 9800MP Insertion Flow Meter for Hazardous Locations\u003c\/h3\u003e Insertion style thermal mass flow meters include a sensor and probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow inlet tube. Master-Touch 9800MP insertion flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. The tube length is determined by the size of the process pipe. Large ducts or stacks may require multiple averaging tubes to achieve the very best accuracy. For problematic or unique installations, please consult the factory. Integral style thermal mass flow meters have all the electrical components and connections Â within one enclosure. This enclosure offers a rating for hazardous environments. The enclosure can mount directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eFlow Averaging Thermal Mass Flow Meter from Eldridge Products Inc. (EPI)\u003c\/h3\u003e Our patented Flow Averaging Tubes (FAT) use the principle of convective heat transfer to directly measure mass flow and are suitable for most applications with limits in available straight run. In many installations, the up-stream straight run can reduce to three diameters. The probe has several large diameter inlet ports along the length of the upstream impact surface. The pressure at each inlet port averages inside the tube to create the axial flow through the tube and across the flow sensor. The gas returns to the main flow stream through the ports near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still some require minor adjustment to achieve the best accuracy. \u003ch3\u003eSuperior Insertion Flow Measurement and Calibration\u003c\/h3\u003e EPI insertion flow meters provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. In addition, each flow meter features calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eAccuracy: Â±(1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e \u003cli\u003eRepeatability: Â±0.2% of full scale\u003c\/li\u003e \u003cli\u003eSensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003eGas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003eGas pressure effect: negligible over Â±50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMaster-Touch 9800MP HAZ FAT for Hazardous Locations\u003c\/h3\u003e EPIâs HAZ series full assembly is suitable for use in hazardous locations with T2, T3, and T4 approvals available in domestic and also in international markets. The diecast aluminum, \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Type 4X\u003c\/a\u003e watertight enclosure is both flame and explosion-proof and features a corrosion resistant finish. \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eDomestic: CSA\/CUS\u003c\/a\u003e \u003cul\u003e \u003cli\u003eClass1 Group B, C, D\u003c\/li\u003e \u003cli\u003eClass2 Group E, F, G\u003c\/li\u003e \u003cli\u003eClass3\u003c\/li\u003e \u003cli\u003eNEMA Type 4X\u003c\/li\u003e \u003c\/ul\u003e International: T2, T3, and T4 \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.kosha.or.kr\/extapp\/english\/index.do\" target=\"_blank\" rel=\"nofollow noopener\"\u003eKOSHA\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2025\/10\/Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-30274 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2025\/10\/Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas.jpg\" alt=\"Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas\" width=\"1000\" height=\"689\"\u003e\u003c\/a\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878434660483,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Series-9800-MP-Insertion-probe-FAT-flow-averaging-tube-thermal-flow-meter-eldridge-products-psc-texas.png?v=1763386612"},{"product_id":"multipoint-flow-meter-master-touch-series-9000mp","title":"Multipoint Flow Meter, Master-Touch Series 9000MP","description":"\u003cp\u003eFor applications that require advanced multipoint measurements of thermal mass flow, the 9000MP Multipoint flow meter is the essential choice for you. This sensor flow enclosure on this multipoint flow meter system, from Eldridge Products Inc. (EPI) is highly durable and can be in service in wet, corrosive and high temperature environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel continuous hinge and stainless steel corner screws\u003c\/li\u003e\n\u003cli\u003eMaintenance free and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eGaskets are made from continuously poured polyurethane foam\u003c\/li\u003e\n\u003cli\u003eThe remote enclosure is also durable and watertight\n\u003cul\u003e\n\u003cli\u003eFlat cover with bonded window\u003c\/li\u003e\n\u003cli\u003eStainless steel continuous hinge as well as stainless steel corner screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAble to effectively function in any large air intake ducts, air exhausts, or flue stacks, these dynamic and advanced flow meters deliver unparalleled service. Perfect for large industry settings and currently in use at many pulp and paper mills and also power source companies across the world, the Series 9000MP is the pinnacle of large-scale thermal mass flow insertion flow meters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMultipoint Flow Meter, Master-Touch Series 9000MP\u003c\/h2\u003e\n\u003cp\u003eA unique feature of the 9000MP multipoint flow meters is that they can integrate an optional Air Purge System, which provides a simple way to clean the sensors. This feature is completely dynamic, giving you control over duration as well as frequency with EPI’s state-of-the-art Master-Touch Software.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerfect for large scale industry operations\u003c\/li\u003e\n\u003cli\u003eMultiple probe system for reliability\u003c\/li\u003e\n\u003cli\u003eReplaceable and removable sensors\u003c\/li\u003e\n\u003cli\u003eConstant and Trustworthy monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaster-Touch products include a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, and also stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance.\u003c\/p\u003e\n\u003cp\u003eThe sensor assembly is large, rugged, in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through EPI's proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMaster-Touch 9000MP Multigen Multiple Point Insertion Flow Meter\u003c\/h2\u003e\n\u003cp\u003eMaster-Touch Multigen multiple point flow meters provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter offers calibration using standards traceable to the National Institute of Standards and Technology (\u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" title=\"National Institute of Standards and Technology\" rel=\"noopener\"\u003eNIST\u003c\/a\u003e).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ±(1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e\n\u003cli\u003eRepeatability: ±0.2% of full scale\u003c\/li\u003e\n\u003cli\u003eSensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003eGas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003eGas pressure effect: negligible over ±50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e9000MP Multipoint Flow Meter for Gas Flows\u003c\/h2\u003e\n\u003cp\u003eMultipoint flow meter systems measure gas flows where two or more sensing points are necessary due to large cross-sectional areas, such as large air intake ducts, air exhaust, or flue stacks. Master-Touch 9000MP Multipoint flow meter Systems are widely in use throughout the world, providing our customers with years of steady, reliable service. In combination with EPI's new Air Purge System, Master-Touch 9000MP multiple point flow systems are ideal to an even greater variety of industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe probe design supports applications as diverse as ambient air flows in HVAC ducts, exhaust gas in large diameter stacks, boiler NOx efficiency systems, and municipal waste incinerators. Our customers include global companies for example, environmental\/ HVAC system integrators, pulp and paper mills, power and energy companies, etc. The configuration and installation options support facility retrofits as well as the most modern new construction requirements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eConfiguration of the EPI Master-Touch Thermal Mass Flowmeter\u003c\/h2\u003e\n\u003cp\u003eThe Master-Touch 9000MP Multipoint System includes one or more 9000MP probes and a 9600MP System Control Panel. The 9000MP flow transmitter probe assembly is the heart of the system. The probe assembly typically has two or more flow sensors mounted in a 1.5\" OD probe shaft. The 9000MP probe’s sensors are removable for field replacement in case of damage. Each sensor matches to its own bridge board and microprocessor to function, in effect, as a complete flow meter.\u003c\/p\u003e\n\u003cp\u003eThe linearized output signals from the multiple sensor assemblies in each probe average to create one overall probe output signal. The probe’s average output signal transmits to a Master-Touch 9600MP System Control Panel (SCP). If the installation contains more than one probe, the output signals from all the probes transmit to the SCP. Then, the SCP averages the values to create one system output. The System Control Panel is housed in a 12\" x 10\" \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eNEMA 4X\u003c\/a\u003e fiberglass enclosure.\u003c\/p\u003e\n\u003cp\u003eThe SCP provides the power for the probe assemblies and receives the average outputs over a four-wire cable to each probe. It also includes its own microprocessor assembly for system-level control and flow display. The SCP provides two analog output signals (0–5 VDC and 4–20 mA), as well as RS232 \u0026amp; RS485 \u003ca rel=\"noopener\" href=\"https:\/\/www.modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus RTU\u003c\/a\u003e communications. The 4–20 mA grand average output can drive up to 1200 ohms.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOptional Air Purge System\u003c\/h2\u003e\n\u003cp\u003eThe optional Air Purge System (APS) provides a means of cleaning the sensors in applications where particulates cause problems. Operators can externally control the frequency and duration of the purge cycle or by using the Master-Touch software. The system can also be set to maintain the flow rate at its level when the purge is active. This important option preserves the integrity of the flow rate and elapsed total data which might otherwise be compromised by the flow of the purge gas.\u003c\/p\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs).  A 316 Stainless Steel sheath encapsulates the platinum sensing element wire or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD with the other RTD acting as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878434726019,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-EPI-thermal-mass-multipoint-flowmeter-flue-gas-measurement-process-solutions-texas.png?v=1763386613"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/collections\/Bronkhorst-mini-CORI-FLOW-Coriolis-Flow-Meter-Low-Flow-MFC-MFM-Mass-Flow-Controller-Liquid-Gas-Flowmeter-Process-Solutions-Corp-PSC-Texas_ab2e1e92-805a-4384-a971-a7014f011e26.png?v=1771536038","url":"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers.oembed","provider":"Process Solutions Corp.","version":"1.0","type":"link"}