{"title":"HART Protocol","description":"","products":[{"product_id":"microtrek-microwave-level-transmitter","title":"MicroTREK Microwave Level Transmitter","description":"\u003cul\u003e\n\u003cli\u003e2-wire compact microwave level transmitter\u003c\/li\u003e\n\u003cli\u003erod, cable, or coaxial probe\u003c\/li\u003e\n\u003cli\u003esegmented rod probe version\u003c\/li\u003e\n\u003cli\u003egraphic display\u003c\/li\u003e\n\u003cli\u003e4-20 mA + HART output + relay \u003cem\u003e(optional)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003ehigh pressure, high temperature range\u003c\/li\u003e\n\u003cli\u003ehighest process pressure: 40 bar (580 psi)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP67 protection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003emedia with turbulent surface, dense dust, vapor, or pressurized gas layers above the product surface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMicroTREK Microwave Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe MicroTREK microwave level gauge from Nivelco operates based on measuring the travel time of impulse reflections (TDR – Time Domain Reflectometry). This level transmitter generates microwave impulses in the sensor, which travel at the speed of light. Part of the impulse energy is reflected from the surface depending on the material. The reflected signal's travel time is measured and processed by the module's electronics, and then it is converted to a volume-proportional level-proportional signal. Reflections depend heavily on the medium's dielectric constant (ε\u003csmall\u003er\u003c\/small\u003e), which must be at least 1.4 for successful measurement. The propagation speed of microwave impulses in a vacuum, air, and other gases is virtually the same. Distance measurement is therefore independent of the medium within the given limits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eextremely small deadband\u003c\/li\u003e\n\u003cli\u003eadvanced threshold management\u003c\/li\u003e\n\u003cli\u003efalse echo suppression\u003c\/li\u003e\n\u003cli\u003eprobe correction table (SCT)\u003c\/li\u003e\n\u003cli\u003elowest ε\u003csmall\u003er\u003c\/small\u003e ≥ 1.4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e12 to 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e−22 to 140 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e−22 to 392 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eup to 580 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e0 to 100 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e4 to 20 mA + HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e\n\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" title=\"ATEX Certification Standards\"\u003eATEX\u003c\/a\u003e, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/services\/hazardous-areas-iecex-certification-international-market-access\" target=\"_blank\" title=\"IECEx Certification Standards\"\u003eIECEx\u003c\/a\u003e, INMETRO, UKCA Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eDielectric Constant Values (ε\u003csmall\u003er\u003c\/small\u003e)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eButane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5-10\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCooking O\u003c\/strong\u003e\u003cstrong\u003eil\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLPG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6-1.9\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimestone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1-9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKerosene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8-2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAcetone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrude Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiesel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMethanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasoline\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGlycol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsphalt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrobenzene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClinker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4-3.6\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSulfuric Acid\u003c\/strong\u003e \u003cem\u003e(T=68˚F [20˚C])\u003c\/em\u003e\n\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e: Ex ia G, Ex ia D, Ex ta\/tb D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Ex\u003c\/strong\u003e: Ex ia G, Ex ia D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINMETRO\u003c\/strong\u003e: Ex ia G, Ex ia D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA Ex\u003c\/strong\u003e: Ex ia G, Ex ia D, Ex ta\/tb D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eCommon uses of PiloTREK Microwave Level Transmitter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003elevel, distance, or volume measurement of liquids, powders, and granules with ε\u003csmall\u003er \u003c\/small\u003e\u0026gt; 1.4\u003c\/li\u003e\n\u003cli\u003eagriculture\u003c\/li\u003e\n\u003cli\u003econstruction materials\u003c\/li\u003e\n\u003cli\u003echemical industry\u003c\/li\u003e\n\u003cli\u003efood and beverage production\u003c\/li\u003e\n\u003cli\u003epower plants\u003c\/li\u003e\n\u003cli\u003eoil and energy sector\u003c\/li\u003e\n\u003cli\u003erevenue water and wastewater industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eMono Cable, Mono Rod, or Mono Segmented Rod\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecement, limestone, fly ash, alumina, soot\u003c\/li\u003e\n\u003cli\u003eall high viscosity liquids\u003c\/li\u003e\n\u003cli\u003emineral powders\u003c\/li\u003e\n\u003cli\u003eclean and contaminated liquids\u003c\/li\u003e\n\u003cli\u003estilling wells \u003cem\u003e(calibration required)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eplastic coated probe for aggressive substances\u003c\/li\u003e\n\u003cli\u003eslightly conductive foams\u003c\/li\u003e\n\u003cli\u003ehigh temperature applications\u003c\/li\u003e\n\u003cli\u003ebypass applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTwin Cable\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003etank parks with solvents, oil, and fuels\u003c\/li\u003e\n\u003cli\u003ewater storage tanks\u003c\/li\u003e\n\u003cli\u003eplastic granules\u003c\/li\u003e\n\u003cli\u003eproducts with low dielectric constant\u003cem\u003e (ε\u003csmall\u003er\u003c\/small\u003e \u0026gt; 1.8)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eany liquids or light granules\u003c\/li\u003e\n\u003cli\u003enarrow tanks\u003c\/li\u003e\n\u003cli\u003ewhere minimal dead zone is needed\u003c\/li\u003e\n\u003cli\u003emounting close to tank wall is possible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTwin Rod\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eplastic granules\u003c\/li\u003e\n\u003cli\u003ecoated tanks\u003c\/li\u003e\n\u003cli\u003eclean and contaminated liquids\u003c\/li\u003e\n\u003cli\u003efine powders\u003c\/li\u003e\n\u003cli\u003ewhere minimum dead zone is needed\u003c\/li\u003e\n\u003cli\u003enarrow tanks\u003c\/li\u003e\n\u003cli\u003emediums with low dielectric constant and slightly moving products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eCoaxial Pipe\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003esmall vessels and tanks up to 20 ft (6 meters) tall\u003c\/li\u003e\n\u003cli\u003esolvents or liquefied gases\u003c\/li\u003e\n\u003cli\u003eliquefied petroleum gas (LPG) or liquefied natural gas (LNG)\u003c\/li\u003e\n\u003cli\u003eclean liquids with low dielectric constant\u003c\/li\u003e\n\u003cli\u003eagitated or flowing liquids – the probe acts as a stilling well\u003c\/li\u003e\n\u003cli\u003eliquid or vapor spray near the probe\u003c\/li\u003e\n\u003cli\u003ecan be heated\u003c\/li\u003e\n\u003cli\u003econtact possible with metallic object or tank wall\u003c\/li\u003e\n\u003cli\u003ewhere no dead zone is allowed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45595157528707,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/MicroTREK-Microwave-Level-Transmitter-01.webp?v=1755686977"},{"product_id":"pr-6437-din-rail-temperature-transmitter","title":"PR 6437 DIN-Rail Temperature Transmitter","description":"\u003cp\u003eThe PR 6437 DIN-Rail Temperature Transmitter is a high-performance industrial \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and also process measurement in automation systems. The 6437 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, offers flexible sensor support including RTD, thermocouple (TC), bipolar mV, linear resistance, and potentiometer inputs. As a result, the PR 6437 delivers accurate 4-20 mA output with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 communication support for advanced diagnostics, remote configuration, and data access. Its wide compatibility makes this \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e ideal for integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management software in manufacturing, energy, chemical processing, as well as HVAC environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of thermocouple and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eIdeal for critical applications requiring superior accuracy and\/or sensor redundancy as well as drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 6437 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6437A DIN-Rail Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6400\/2-wire-hart-7-temperature-transmitter-6437a\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 6437A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6437D Ex DIN-Rail Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6400\/2-wire-hart-7-temperature-transmitter-6437d\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 6437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6437 DIN-Rail Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6437 DIN-Rail temperature transmitter supports single or true dual inputs with sensor redundancy and drift detection. Thus, the 6437 Series ensures reliable measurement and improves uptime, even in critical applications. Dual input mapping options allow dynamic reporting of average, differential, minimum\/maximum, and other process variables for enhancing control as well as analysis. This DIN-rail temperature transmitter features programmable damping (0-60s) and excellent signal-to-noise performance to deliver stable outputs under varying conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter, accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime. \u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example: dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span as well as ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen in addition to custom linearization. \u003c\/li\u003e\n\u003cli\u003eProgrammable input limits with runtime metering ensure maximum process traceability and also provide sensor out of range protection. \u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\" title=\"International Electrotechnical Commission\" rel=\"noopener\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" title=\"NAMUR Association\" rel=\"noopener\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eFailure rates for 6437xxSx correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eAble to withstand demanding industrial environments, the PR 6437 offers 2.5 kVAC galvanic isolation, complies with NAMUR NE21\/NE43\/NE44\/NE89, and is also fully assessed to IEC 61508 SIL 2\/3. As a result, the PR 6437 \u003cmeta charset=\"utf-8\"\u003eDIN-Rail Temperature Transmitter is suitable for safety-critical systems. With up to 84 channels per meter on DIN-rail mounts as well as configuration via HART or PR Loop Link, this transmitter combines precision, connectivity, and reliability for modern process control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 inputs per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via \u003ca href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\" title=\"PReset Programming Software\" rel=\"noopener\"\u003ePReset\u003c\/a\u003e using the PR 5909 Loop Link \/\u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\" title=\"HART Protocol\" rel=\"noopener\"\u003eHART\u003c\/a\u003e modem, or by Asset Management tool, for example: \u003ca href=\"https:\/\/pactware.com\/\" target=\"_blank\" title=\"PACTware Programming Software\" rel=\"noopener\"\u003ePactware\u003c\/a\u003e, AMS, HART communicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC.jpg?v=1770236244\" alt=\"PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-P.jpg?v=1770236267\" alt=\"PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46471256801411,"sku":"6437A1--","price":577.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46471256834179,"sku":"6437A1S-","price":610.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46471256866947,"sku":"6437A1-M","price":602.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46471256899715,"sku":"6437A1SM","price":638.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46471256932483,"sku":"6437A2--","price":399.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46471256965251,"sku":"6437A2S-","price":700.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46471256998019,"sku":"6437A2-M","price":691.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46471257030787,"sku":"6437A2SM","price":724.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46471257063555,"sku":"6437D1--","price":692.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46471257096323,"sku":"6437D1S-","price":726.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46471257129091,"sku":"6437D1-M","price":719.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46471257161859,"sku":"6437D1SM","price":755.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46471257194627,"sku":"6437D2--","price":781.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46471257227395,"sku":"6437D2S-","price":817.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46471257260163,"sku":"6437D2-M","price":807.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46471257292931,"sku":"6437D2SM","price":844.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437-A-DIN-Rail-Temperature-Transmitter-PR-electronics-industrial-temperature-measurement-HART-protocol-2-wire-temp-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770236286"},{"product_id":"tidalflux-2300-magmeter-for-partially-filled-pipes","title":"TIDALFLUX 2300, Magmeter for Partially Filled Pipes","description":"\u003cp\u003eThe TIDALFLUX 2300 is an electromagnetic flow meter (EMF), or magmeter, with patented, capacitive level measurement for use in partially filled pipes (up to DN1600 \/ 64 inches). This magmeter is the ideal solution for flow measurement of municipal or industrial wastewater in pressureless transport lines. However, this magnetic flow meter is also suitable for measurement of effluent brine from seawater and well water injection applications. Unlike open channel systems (Venturi, V-notches etc.) these inline flow meters are a closed measuring solution without obstructions. In addition, these magmeters offer a much better accuracy at lower total costs of ownership.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eintegrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)\u003c\/li\u003e\n\u003cli\u003eelectrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface\u003c\/li\u003e\n\u003cli\u003e220\/110 V or 24 VDC power supply\u003c\/li\u003e\n\u003cli\u003eaccurate (±1%) and cost-saving alternative to open channel systems\u003c\/li\u003e\n\u003cli\u003eflange: DN200 to DN1600 \/ 8 to 64 inches\n\u003cul\u003e\n\u003cli\u003evarious flange standards like DIN, ANSI and JIS\u003c\/li\u003e\n\u003cli\u003epolyurethane liner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 x 4-20 mA, pulse, HART, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus\u003c\/a\u003e, as well as \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.profibus.com\" target=\"_blank\" title=\"PROFINET Protocol\"\u003ePROFINET\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the TIDALFLUX 2300 Magmeter for Partially Filled Pipes*\u003c\/h2\u003e\n\u003cp\u003eThe measuring tube of the TIDALFLUX 2300, from KROHNE, comes with a polyurethane (PUR) liner for abrasion and chemical resistance. Its smooth surface prevents build-up of fat and other deposits which minimizes the need for regular cleaning. For direct burial installation or applications in areas that can be partially flooded, this flow meter can also offer IP68 \/NEMA 6P versions. Due to the presence of flammable hydrogen sulphide (H\u003csmall\u003e2\u003c\/small\u003eS) in many wastewater applications, this magmeter also has ATEX \/ IECEx zone 1 approval. Furthermore, the TIDALFLUX 2300 comes with extensive diagnostics. In addition, the OPTICHECK service tool can carry out full on-site verification of these flow meters without process interruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e\n\u003cli\u003eclosed measurement solution with patented integrated non-contact level measurement\u003c\/li\u003e\n\u003cli\u003efor effluent and slurries in gravity pipelines \/ sewers\u003c\/li\u003e\n\u003cli\u003echemically and also abrasion resistant PUR liner\u003c\/li\u003e\n\u003cli\u003eaccuracy: ±1% of measured value (MV)\u003c\/li\u003e\n\u003cli\u003eelectrodes not in contact with floating deposits\u003c\/li\u003e\n\u003cli\u003eoptional version for direct burial installation and flooded areas (\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP68\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003estandard factory calibration, also no on-site calibration requirements\u003c\/li\u003e\n\u003cli\u003eextensive flow meter and process diagnostics, which exceed the NE 107 requirement\u003c\/li\u003e\n\u003cli\u003ealso for use in hazardous areas zone 1: ATEX, IECx Zone 1, Class 1 Div 2\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eCommon Applications of this Magmeter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater and wastewater applications in partially filled and gravity feed pipes\u003c\/li\u003e\n\u003cli\u003ecost-effective replacement of expensive siphon tube constructions\u003c\/li\u003e\n\u003cli\u003esurface water flow measurement\u003c\/li\u003e\n\u003cli\u003ebiological and also chemical wastewater\u003c\/li\u003e\n\u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e\n\u003cli\u003ecombined sewer overflows (CSOs)\u003c\/li\u003e\n\u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e\n\u003cli\u003erainwater retention basins\u003c\/li\u003e\n\u003cli\u003einfluent \/ intake as well as effluent at wastewater treatment plants\u003c\/li\u003e\n\u003cli\u003edischarge to surface water\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363750531,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/krohne-tidalflux-2300-magmeter-for-partially-filled-pipes-flow-measurement-electromagnetic-flow-meter-process-solutions-corp_42b2897a-4911-4e0f-be7b-b6b63ece52df.png?v=1763385143"},{"product_id":"dk32-rotameter-va-meter","title":"DK32 Rotameter (VA Meter)","description":"The DK32 is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/variable-area\/\"\u003evariable area flow meter (VA meter)\u003c\/a\u003e, also known as a rotameter or purge meter, is ideal for measuring \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003elow flow rates of liquids and gases\u003c\/a\u003e. This durable flow meter is particularly suitable for flow monitoring and dosing chemicals in the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal water and wastewater industry\u003c\/a\u003e. Due to its robust all-metal design, the DK32, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, is also ideal for difficult process conditions with temperatures up to 392ËF (200ËC) or pressures up to 400 barg (5800 psig). Furthermore, it is available with a metering valve as standard to accurately set the flow value. \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eunlike the \u003ca href=\"https:\/\/psctexas.com\/product\/dk34-va-meter-rotameter\/\"\u003eDK34\u003c\/a\u003e, the DK32 features top\/bottom valve in addition to rear process connection\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003enarrow, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact design\u003c\/a\u003e enabling a high packing density\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eeasy installation and commissioning\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ehigh resistance to pressure and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esturdy metal design: stainless steel or alloy\u003c\/li\u003e \u003c\/ul\u003e The DK32 rotameter can operate without auxiliary power supply. Furthermore, it features a local indication with optional minimum\/maximum limit switches (\u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMUR\u003c\/a\u003e), a reed contact, or analog output (4-20 mA or \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e). To provide constant flow rates, in case of variable inlet or outlet pressures, this VA meter is also available with flow regulators. This rotameter comes with horizontal or vertical process connections for NPT or G thread, flange adapters, as well as many other connection options. The DK32 variable area meter has various approvals for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e and is suitable for use in \u003ca href=\"https:\/\/www.ul.com\/services\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSafety Instrumented Systems (SIL applications)\u003c\/a\u003e. \u003ch3\u003eFeatures of the DK32 Rotameter*\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-25923 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/KROHNE-DK32-Rotameter-Purge-VA-Meter-Waste-Water-Chemical-Dosing-PSC-Texas.jpg\" alt=\"KROHNE-DK32-Rotameter-Purge-VA-Meter-Waste-Water-Chemical-Dosing-PSC-Texas\" width=\"750\" height=\"328\"\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003esimple, low-cost installation: able to measure and display without auxiliary power supply\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003erotameter (purge meter) with 2 optional limit switches for flow monitoring\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003evarious stainless steel and alloy sensor materials\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eoptional surface passivation with \u003ca href=\"https:\/\/www.silcotek.com\/coatings\/silconert\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSilcoNert 2000\u003c\/a\u003e for trace-level analysis\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65\/66 ratings\u003c\/a\u003e\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003efull scale value for liquids: 0.4 to 40 GPH (1.6 to 150 l\/h)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003efull scale value for gases: 0.6 to 170 SCFH (16 to 4,800 l\/h)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eturndown ratio 10:1\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003emaximum measuring error: Â±4% (according to VDI\/VDE 3513-2) as well as Â±3% of full scale\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esuitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eapproved for hazardous areas\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/variable-area\/\"\u003eCommon Uses of a Rotameter\u003c\/a\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edosing of chemical additives such as foam inhibitors, emulsifiers, flocculants, etc.\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eheating as well as cooling water\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esample flow monitoring\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003egas sparging in liquids\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003einjection skids\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ecooling water\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003edry-run prevention of pumps\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363816067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-dk32-rotameter-variable-area-flow-meter-purge-meter-low-flow-liquid-dosing-process-solutions-corp_b499b9a8-cd5d-4a33-80c6-eeda963aa70a.png?v=1763385146"},{"product_id":"optiflux-2300-flow-meter-for-water","title":"OPTIFLUX 2300, Flow Meter for Water","description":"The OPTIFLUX 2300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, for all demanding \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e. This high-end \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e for water is particularly suitable for municipal water as well as wastewater applications that require high accuracy and extensive diagnostics. The OPTIFLUX 2300 magmeter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, has the widest diameter range available in the market: DN25 to DN3000 (1 to 120\"). In addition, it complies with requirements for custody transfer (MID MI-001, OIML R49). This flow meter also allows for custody transfer measurement without inlet\/outlet runs (0D\/0D) according to OIML R49 accuracy class 1. Furthermore, it offers a wide range of approvals for potable water. Overall, the OPTIFLUX 2300 is an effective alternative to mechanical water meters, not least in custody transfer measurement of potable water. \u003cimg class=\"alignright wp-image-25901 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas\" width=\"630\" height=\"740\"\u003e \u003cul\u003e \u003cli\u003e0D\/0D installation according to MID MI-001 and OIML R49 accuracy class 1\u003c\/li\u003e \u003cli\u003eflange: DN25 to DN3000 (1 to 120\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, as well as PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.2% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003emeets potable water standards: ACS, DVGW, NSF, TZW, KTW, WRAS, KIWA, etc.\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2300 also features a \"virtual reference\" option, which allows for a measuring mode without the need of additional grounding rings. This feature enables substantial cost savings in terms of installation and procurement. Installation in measurement chambers, which are subject to (constant) flooding, is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. Moreover, the OPTIFLUX 2300 offers various digital communication options, making it a flexible option for many processes. In addition, operators can carry out a full on-site verification of this flow meter for water without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2300 Magnetic Flow Meter for Water*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turn down ratio: up to 1000:1)\u003c\/li\u003e \u003cli\u003eno inlet\/outlet run requirements for OIML R49 class 1 accuracy\u003c\/li\u003e \u003cli\u003ewidest diameter range available in the market\u003c\/li\u003e \u003cli\u003eavailable with patent virtual reference grounding method, which provides cost-saving installation without grounding rings\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner for excellent chemical resistance\u003c\/li\u003e \u003cli\u003eoptions for burial installation and constant flooding (IP68)\u003c\/li\u003e \u003cli\u003elargest diameter range with custody transfer approval\u003c\/li\u003e \u003cli\u003etamper proof\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003eon-site verification of this flow meter for water with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of this Flow Meter for Water Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral as well as advanced municipal water and wastewater applications\u003c\/li\u003e \u003cli\u003ecustody transfer measurement\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer) of potable water\u003c\/li\u003e \u003cli\u003eabstraction as well as irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater treatment plants such as raw water, drinking water, treatment chemicals, and more\u003c\/li\u003e \u003cli\u003ewastewater networks\u003c\/li\u003e \u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e \u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e \u003cli\u003emunicipal wastewater treatment plants\u003c\/li\u003e \u003cli\u003edesalination plants such as for sea water, permeate, brine, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363881603,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2000-Series-Electromagnetic-Flow-Meter-for-Municipal-Water-Magmeter-Process-Solutions-Texas_3ea1af8f-ab42-4515-85e7-a271b6792bb4.png?v=1763385149"},{"product_id":"inline-flow-meter-master-touch-series-86008700-mp-haz","title":"Inline Flow Meter, Master-Touch Series 8600-8700 MP HAZ","description":"\u003cp\u003eThe 8600-8700 MP Inline Flow Meter Series provides accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" rel=\"nofollow noopener\" target=\"_blank\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaster-Touch Series 8600-8700 MP HAZ, Inline Flow Meter\u003c\/h3\u003e\n\u003cp\u003eMaster-Touch Series products include a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. Then it is controlled by the temperature sensor and bridge circuitry. Furthermore, our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003ch3\u003e8600-8700 Series Inline Flow Meter for Use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazardous Locations\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cp\u003eOur inline flow meter for thermal mass flow measurement includes a flow section that is usually specified to match the userâs flow conduit and is then plumbed directly into the process line. This design also has the sensing elements mounted directly in the flow section for exposure to the process gas. This thermal mass flow inline flow meter is available in sizes from 1\/4\" pipe through 4\" pipe or tube and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as necessary. Pipe sizes more than 4\" typically require insertion style thermal mass flow meters. This integral style inline flow meter has all the electrical components and connections located within one enclosure. Additionally, this enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003ch3\u003eOperating Principle\u003c\/h3\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Furthermore, our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. In addition, our microcontroller operate with smart sensor technology that preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, which causes an increase in the power necessary to maintain a balance between the RTDs. As a result, this increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes. So, the output signal is a true mass flow rate signal.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8600â8700 MP HAZ\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26148 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\" alt=\"Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp\" width=\"750\" height=\"513\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eCertifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApprovals\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Orientation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Housing\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003ePipe Information\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 4\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 6\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e), Multi-Range + Temp Out, Multi-Range + No Temp, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eBACnet\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eProfibus\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e (when applicable): Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMounting Requirements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMNPT Ends\u003c\/li\u003e\n\u003cli\u003eButt End\u003c\/li\u003e\n\u003cli\u003eFlange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSensor Wetted Materials Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eStainless Steel 316L\u003c\/li\u003e\n\u003cli\u003eHastelloy C-276\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364340355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp_60549b24-6b99-4485-bd1a-d8863121157d.png?v=1763385157"},{"product_id":"eldridge-products-valumass-series-500-val-inline-flow-meter","title":"Eldridge Products, ValuMass Series 500 VAL Inline Flow Meter","description":"ValuMass 500 VAL flow meters provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, is undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. Like the ValuMass Series 540, the ValuMass Series 500 inline \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flowmeter\u003c\/a\u003e also uses the proprietary temperature compensation techniques using two RTD (resistance temperature detectors). This design allows the ValuMass Series to deliver accurate measurements day in, day out. If you require reliable mass measurement for an air and gas flow application with an inline installation, the ValuMass Series 500 is an excellent choice that provides great value at a great price. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26153 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch3\u003eThermal Mass Flow Meters\u003c\/h3\u003e ValuMass 500 Series VAL is a rugged, cleanable, thermal mass flow sensor. These flow meters consist of a sensor assembly that utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors rely upon a ceramic substrate that then receives a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged as well as relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. In addition, it is controlled by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003e500 Series Flow Meter from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e\n\u003c\/h3\u003e Our inline style thermal mass flow meters include a flow section that matches the userâs flow conduit and then usually plumbs directly into the process line. Furthermore, the sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2.5\" pipe. The 3.5\" long flow sections have MNPT ends as standard for easy mounting in the process line (options available for pipe sizes over 2.5\"). Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure features a rating for non-hazardous environments. Then the enclosure mounts directly to the inline flow section assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eOperation Principle\u003c\/h3\u003e Thermal mass flow meters from Eldridge Products use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options Eldridge Products - ValuMass 500 Series VAL\u003c\/h3\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003ePipe Information\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 2.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 3.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus RTU\u003c\/a\u003e), \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e: Standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e: 0-5, 0-10\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMounting Requirements\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eMNPT Ends\u003c\/li\u003e \u003cli\u003eButt End\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Wetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eStainless Steel 316L\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364405891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-ValuMass-Inline-Thermal-Mass-Flow-Meter-500-VAL-EPI-Process-Solutions-Corp.png?v=1763385160"},{"product_id":"rc-systems-gas-and-flame-detectors","title":"RC Systems Gas and Flame Detectors","description":"\u003cimg class=\"size-full wp-image-1673 alignnone\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/7000-AL-S.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e\u003cimg class=\"alignnone size-full wp-image-1677\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/SenSmart_6000_AL_SS.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e\u003cimg class=\"alignnone size-full wp-image-1689\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/SenSmart_3000_AL_SS.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e\u003cimg class=\"alignnone size-full wp-image-1691\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/AL-Blind-S.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e     \u003cstrong\u003eToxic and Oxygen Gas Detectors\u003c\/strong\u003e RC Systems offers a wide range of toxic and oxygen gas detectors. Each SenSmart toxic and oxygen gas detector model is designed to deliver optimum price, performance and versatility to fit any situation. Field swappable smart electrochemical sensors are available for Oxygen (O2), Hydrogen Sulfide (H2S), Sulfur Dioxide (SO2), Ammonia (NH3), Chlorine (Cl2), Hydrogen Fluoride (HF) and many other toxic gases. SenSmart gas detectors offer Important features including heated sensors (SenSmart 3100 \u0026amp; 6100), Ethernet \/ Web Server (SenSmart 6100) and wireless communications with the easy to install SenSmart 7100. For lowest price points consider the SenSmart 1100 and 2100 4-20mA loop powered gas detectors. \u003ca href=\"https:\/\/www.rcsystemsco.com\/toxic-and-oxygen-gas-detectors\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e   \u003cimg class=\"alignnone size-full wp-image-1694\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/safeye900_high.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e\u003cimg class=\"alignnone size-full wp-image-1695\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/millenium-IR-gas-detector-group.png\" alt=\"\" width=\"125\" height=\"600\"\u003e \u003cstrong\u003eCombustible Gas Detectors\u003c\/strong\u003e RC Systems combustible gas detectors utilize both catalytic bead sensors and infrared sensors to provide reliable readings in any application. Catalytic bead combustible gas sensors consist of a reference bead and an analytic bead, wired into a Wheatstone bridge circuit. In these detectors, a small amount of gas is burned on the analytic bead, causing it to get hotter and increasing its resistance and voltage drop. This creates an imbalance of the bridge circuit that is proportional to gas concentration. IR gas detectors use band pass filters to pass infrared light in analytical and reference wavelengths through a volume of gas. Both wavelengthsâ paths are measured, and the light is reflected back to IR detectors. The target gas reduced the intensity of the analytical beam, but not the reference beamâsimilar to the way smoke affects visible light. The gas sensorâs reference detector monitors the intensity of the two infrared source and compensates for loss of signal caused by dirty optics or source aging. RC Systems offer both open path combustible gas detectors and single point combustible gas detectors. These units are designed to detect a wide range of gases, including acetylene, butane, hexane, methane, propane, and more. \u003ca href=\"https:\/\/www.rcsystemsco.com\/catalytic-bead\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e \u003cstrong\u003eCarbon Dioxide Infrared Gas Detectors\u003c\/strong\u003e The key components of RC Systemsâ infrared CO2 detectors are the light source, measurement chamber, interference filter, and IR detector. Infrared radiation is directed from the light source, through the measured gas, and into the detector. Specialized filters at the front of the gas detector prevent wavelengths other than those specific to the measured gas from passing through. Light intensity is detected and converted into a gas concentration reading. RC Systems offers two lines of infrared carbon dioxide detectors: SenSmart gas detectors and Millennium Series gas detectors. Both lines utilize RC Systemsâ advanced, innovative gas detection technology to deliver reliable results in nearly any application. \u003ca href=\"https:\/\/www.rcsystemsco.com\/carbon-dioxide-infrared-detectors\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e \u003cstrong\u003ePhotoionization Detectors\u003c\/strong\u003e RC Systemsâ photoionization detector (or PID detector) systems are engineered to detect a variety of organic compounds. These vapor and gas detectors provide effective, reliable performance in a broad range of applications. An RC Systems PID detector is comprised of an ultraviolet lamp that emits photons that are absorbed by the compound in an ionization chamber. Photoionization occurs when an atom\/molecule absorbs light from energy, which in sufficient levels causes and electron to leave, creating a positive ion. Ions produced during this process are collected on electrodes, and the current this generates provides a measure of the analyzed substance. Because only a small fraction of the analyte molecules are actually ionized, this detection method is nondestructive, which allows it to be used in conjunction with another detector to confirm analytical results. The SenSmart 6500 photoionization detector and SenSmart 3500 photoionization detector options utilize cutting-edge technology to ensure accurate results in even the most challenging environments. \u003ca href=\"https:\/\/www.rcsystemsco.com\/photoionization-detectors\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e \u003cstrong\u003eDual Sensor Gas Detectors\u003c\/strong\u003e RC Systems offers a variety of dual sensor gas detectors that provide advanced, economical, and reliable gas detection. These versatile devices are ideal for a range of applications, including toxic gas, carbon dioxide, and combustible gas detection. The SenSmart DUAL gas sensors are easy to use, low-power options are built using RC Systemsâ innovative technology for superior performance. These universal gas detection systems are CSA certified for Class 1, Division 1 or Class 1, Division 2 locations (varies by model). Whatever your gas detection requirements may be, theyâre sure to have the right solution for your needs. \u003ca href=\"https:\/\/www.rcsystemsco.com\/dual-sensor-gas-detectors\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e \u003cstrong\u003e4-20mA Sensor Transmitters\u003c\/strong\u003e RC Systems offers an array of 4-20mA transmitters, all built on our innovative, state-of-the-art technology for superior performance. The SenSmart transmitters provide numerous advanced features and are versatile enough for nearly any application. They are CSA certified for Class 1, Division 1 or Class 1, Division 2 locations (varies by model). \u003ca href=\"https:\/\/www.rcsystemsco.com\/4-20ma_transmitters\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these transmitters.\u003c\/a\u003e \u003cimg class=\"alignleft size-full wp-image-1699\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Spectrex_40_40I.jpg\" alt=\"\" width=\"125\" height=\"600\"\u003e \u003cstrong\u003eFlame Detectors\u003c\/strong\u003e RC Systemsâ flame detectors incorporate the most advanced features and the latest approvals for todayâs industries. All models feature a heated window designed to withstand the harshest conditions, and include HART outputs to provide quality information during installation and maintenance. Most of flame detector options offer an enhanced detection distance and a larger field of view than the industry standard. They provide enhanced reliability and durability, protected by our 5-year warranty. All models are approved for hazardous areas (FM\/ATEX\/IECEx\/CSA and others) for installation in Zone I areas. Theyâre also third-party performance approved (EN54-10, FM, DNV). RC Systemsâ line of flame detectors includes IR3, combined UV\/IR, single UV types, single IR types, and a new multi-IR detector that provides combined hydrocarbon and hydrogen flame detection. \u003ca href=\"https:\/\/www.rcsystemsco.com\/flame-detectors\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eClick here for more information about these detectors.\u003c\/a\u003e","brand":"RC Systems","offers":[{"title":"Default Title","offer_id":45878364536963,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Gas-detectors.jpg?v=1763385165"},{"product_id":"pilotrek-compact-series-microwave-level-transmitter","title":"PiloTREK Compact Series, Microwave Level Transmitter","description":"\u003cul\u003e \u003cli\u003ePlastic, aluminum or stainless steel housing\u003c\/li\u003e \u003cli\u003eStainless steel parabolic, horn, or plastic-coated antenna\u003c\/li\u003e \u003cli\u003ePlug-in graphic display module\u003c\/li\u003e \u003cli\u003eHigh-temperature variant\u003c\/li\u003e \u003cli\u003e2-wire transmitters\u003c\/li\u003e \u003cli\u003e25 GHz (K-band) measuring signal\u003c\/li\u003e \u003cli\u003eNon-contact level metering\u003c\/li\u003e \u003cli\u003eAccuracy up to Â±0.12 inch\u003c\/li\u003e \u003cli\u003eMeasuring range up to 75 feet\u003c\/li\u003e \u003cli\u003e99-point linearization\u003c\/li\u003e \u003cli\u003eExplosion-proof variants available\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLevel measurement of liquids, emulsions, slurries, and other chemicals\u003c\/li\u003e \u003cli\u003eLevel measurement through plastic tank wall\u003c\/li\u003e \u003cli\u003eAgriculture\u003c\/li\u003e \u003cli\u003eConstruction materials\u003c\/li\u003e \u003cli\u003eChemical industry, for mid to large size vessels or chemical tanks\u003c\/li\u003e \u003cli\u003ePharmaceutical industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003ePower plants\u003c\/li\u003e \u003cli\u003eOil industry\u003c\/li\u003e \u003cli\u003eWater and wastewater industry\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eLinearly Polarized Microwave Impulses\u003c\/h4\u003e The PiloTREK Compact Series pulse burst radar level transmitters emit linearly polarized microwave impulses. The polarization plane of the emitted impulses can be rotated fully in some PiloTREK models. The rotation of the polarization plane can minimize unwanted false reflections from disturbing objects or from the tank wall. The orientation of the polarization plane coincides with the line drawn between the cable glands. \u003ch4\u003ePulse Radar Level Transmitter Operations\u003c\/h4\u003e The operation of the non-contact microwave level transmitters is based on the measurement of the time of flight of the microwave burst. The propagation speed of microwave impulses is practically the same in air, gases and in vacuum, independently from the process temperature and pressure, so the measured distance is not affected by the physical parameters of medium to be measured. The level transmitter induces microwave impulses a few nanosecond long in the antenna and a part of the energy of the emitted signals is bounced (reflected) back from the measurement surface depending on the measured media. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level or volume proportional data. The measurability of the level of a specific medium is depending on the signal strength of the reflected microwave impulses. The signal strength of the reflected impulses is considerably depending on the distance to be measured, the relative dielectric constant of the measured medium and the turbulence of the surface. The relative dielectric constant (Îµr) of the medium should be more than 1.4 in case of parabolic design, or it should be more than 1.9 with horn antenna types. \u003ch4\u003eProgramming with Echo Map\u003c\/h4\u003e With the help of the SAP-300 plug-in display, a simplified full-parameter programming can be accomplished. The parameters of measurement and output can be set using the text-based menu system.Â The large LCD dot-matrix display displays the measured values in numerical and bar graph form. The Echo Map feature helps to detect false reflections and aids the optimization of the measurement configuration. The background mapping feature provides excellent solution to ignore unwanted false reflections coming from (not-moving) disturbing objects. For this purpose the instrument needs to map the totally empty tank to create a âbackground imageâ. Then the measurement evaluation software of PiloTREK Compact Series will automatically recognize and ignore the false reflections coming from the disturbing objects inside the tank. \u003ch4\u003ePiloTREK Compact Series Microwave \/ Radar Level Transmitter\u003c\/h4\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e20â¦36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ4â¦140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22â¦356Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ14.5â¦362.6 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4â¦20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1Â½\", 2\" or flanges or sanitary\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eIP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eATEX, IEC Ex, INMETRO\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4 title=\"Page 5\"\u003ePiloTREK Microwave Level Transmitter Model Line-Up\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003ePiloTREK Series\u003c\/th\u003e \u003cth style=\"text-align: center;\" colspan=\"3\"\u003eCompact Microwave Level Transmitter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePlastic housing\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eMetal housing\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eHigh temperature version\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasured values\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eLevel, Distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCalculated values\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eVolume, Mass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eFrequency of the measurement signal\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e~25 GHz (K-band)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e0.6 â 75 ft \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eLinearity error\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e\u0026lt;1.65 ft: Â±1 in; 1.65 â 3.3 ft: Â±0.6 in; 3.3 â 5 ft: Â±0.4 in; 5 â 26.25 ft: Â±0.12 in; \u0026gt;26.25 ft: Â±0.04% of the measured distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal beam angle\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e6Â° \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal Îµr of the medium\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e1.4 \u003cem\u003e(depending on the measuring range)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e1 mm (0.04 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eTemperature error (as per EN 61298-3)\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e0.05% FSK \/ 50 Â°F (-4Â°F...140Â°F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e20 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e4 â 20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDisplay\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eSAP-300 graphical display unit\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring frequency\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e10 â 60 sec as per the application settings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna diameter\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e38 mm (11â2\"), 48 mm (2\"), 75 mm (3\"), 148 mm (6\")\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna material\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eHorn, Parabolic: 1.4571 (316Ti) stainless steel; enclosure: PP, PTFE\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eHorn, Parabolic: 1.4571 (316Ti); enclosure: PTFE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e-22Â°F...212Â°F, (up to 248 Â°F for maximum 2 minutes) with PP antenna enclosure: maximum: 176Â°F\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-22Â°F...356Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMaximal process pressure\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e25 bar (363 psig) at 248Â°F; with plastic antenna enclosure: 3 bar (44 psig) at 77 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eThreaded, Flanged or Sanitary connections\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eIP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e2x M20 x1.5 cable glands + internal thread for 2x 1â2\" NPT cable protective pipe, cable outer diameter: 0.3 â 0.5 inch, wire cross section: max. 1.5 mm2 (AWG 15)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing material\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePlastic (PBT)\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003ePaint coated aluminum or stainless steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSealing\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eViton, EPDM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCommunication certifications\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eR\u0026amp;TTE, FCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2.2 â 3.5 lb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eAluminium: 4.4 â 5.7 lb Stainless steel: 7.9 â 8.6 lb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eAluminium: 6.6 â 7.9 lb Stainless steel: 8.8 â 10 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e*Under reference conditions of reflection and stabilized temperature\u003c\/em\u003e \u003ch4\u003eEx Certified PiloTREK Compact Series Microwave Level Transmitters\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003ePlastic housing\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eMetal housing\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eHigh temperature version with metal housing\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003eEx marking\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eIEC Ex\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia IIB T6 ... T5 Ga\/Gb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia IIB T6 ... T4 Ga Ex ia IIIC T85Â°C ... T110Â°C Da\/Db Ex ta\/tb IIIC T85Â°C ... T110Â°C Da\/Db\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia IIB T6 ... T3 Ga Ex ia IIIC T85Â°C ... T180Â°C Da\/Db Ex ta\/tb IIIC T85Â°C ... T180Â°C Da\/Db\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eATEX\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx II 1\/2 G Ex ia IIB T6 ... T5 Ga\/Gb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eEx II 1G Ex ia IIB T6 ... T4 Ga Ex II 1\/2 D Ex ia IIIC T85Â°C ... T110Â°C Da\/Db Ex II 1\/2 D Ex ta\/tb IIIC T85Â°C ... T110Â°C Da\/Db Ex II 1\/2 G Ex d [ia Ga] IIB T6 ... T4 Ga\/Gb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eEx II 1G Ex ia IIB T6 ... T3 Ga Ex II 1\/2 D Ex ia IIIC T85Â°C ... T180Â°C Da\/Db Ex II 1\/2 D Ex ta\/tb IIIC T85Â°C ... T180Â°C Da\/Db Ex II 1\/2 G Ex d [ia Ga] IIB T6 ... T3 Ga\/Gb\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eIntrinsically safe data\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eLi: 200 Î¼H, Ci: 16 nF, Ui: 30 V, Ii: 140 mA, Pi: 1 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eEx ia: 20 V â 30 V DC, Ex d[ia]: 24 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e2x M20 x1.5 metal cable glands, cable outer diameter: 0.3 â 0.5 inch, wire cross section: maximum 1.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG 15)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878364668035,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PiloTREK_liquids-compact_WGS-150-8-Ex-nivelco-pulse-radar-level-transmitter-noncontact-microwave-hazardous-location-sensor-explosion-proof_6ca630bc-2109-4938-8a39-52b7211a615e.jpg?v=1763385169"},{"product_id":"easytrek-series-ultrasonic-level-transmitters-for-liquids","title":"EasyTREK Series, Ultrasonic Level Transmitters for Liquids","description":"\u003cul\u003e \u003cli\u003e2-wire transmitter with non-contact level metering\u003c\/li\u003e \u003cli\u003enarrow 5Ë beam angle\u003c\/li\u003e \u003cli\u003eexcellent signal processing via QUEST+ software\u003c\/li\u003e \u003cli\u003etemperature compensation,Â 32-point linearization\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/lightning-protection\/\"\u003esecondary lightning protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ePP, PVDF, PTFE housing and transducers\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003elevel and volume measurement, open-channel flow metering\u003c\/li\u003e \u003cli\u003efail-safe indication\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eLevel Sensor Technology Using Echo Detection\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003eultrasonic level metering technology\u003c\/a\u003eÂ of the EasyTREK from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is based on the principle of measuring the time required for the ultrasound pulses to cover the distance from the sensor to the level to be measured and back. The echoes bounced back from the surface of the medium to be measured reach the sensor surface after the time of flight of the ultrasonic impulse. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level, volume, or flow proportional data with the help of the customizable tank dimensions or the pre-programmed flume \/ weir parameters. The intelligent QUEST+ process adaptive signal processing software system ensures that the electronics identifies and validates the liquid surface signal, giving reliable level monitoring.   [embed]https:\/\/www.nivelco.com\/public\/files\/b1dc6bc3-bb2a-42ec-b2dd-36a965dfeef7\/11_EchoTREK.mp4[\/embed] \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eEasyTREK for Liquids Level Transmitter\u003c\/h3\u003e The EasyTREK Series can be used in multi-drop systems connected to MultiCONT process controller and display, or to a PC with the help of the UNICOMM HART USB and RS485 modem or similar. The EasyTREK Series is available with measurement ranges up to 82 feet, providing wide application possibilities. These \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003eultrasonic level transmitters\u003c\/a\u003e are use SenSonic range transducers with a full beam angle of 5 to 7 degrees connected to intelligent electronics featuring the QUEST+ advanced signal processing algorithm. \u003ch3\u003eHART Protocol and PC Communications\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The instruments with HART output can be connected to a PC using a UNICOMM SAK-305 HART-USB modem. All measured values of the EasyTREK ultrasonic level transmitters can be visualized and\/or the instruments can be remotely programmed via digital HART communication. Applicable software for PC: EView2 configuration software or NIVISION process visualization software. The level sensors with HART output can be connected to a PC via Bluetooth wireless connection using a UNICOMM HART- USB-Bluetooth modem (SAT-504). Power supply can be provided for the system with a USB power bank connected to the UNICOMM modem. These ultrasonic level sensors utilize HART communication so they can be used in multidrop systems connected to MultiCONT process controller and display, or to a PC with the help of the UNICOMM HART-USB modem or similar. These level transmitters can also be connected wirelessly to a PC with the SAT-504 Bluetooth HART modem. The EasyTREK Series has a compact size, increased maximum measuring range, decreased minimum measuring range, and can be remotely programmed also with handheld field communicator. \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eUltrasonic Level Transmitters in HART Multidrop Loop\u003c\/h3\u003e The MultiCONT multichannel process controller processes and displays measurement data supplied by HART equipped transmitters connected to a Multidrop loop. The transmitters (also mixed models) can be connected and remote programming can be also performed through theMultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed.Â The visualisation of the data can be done by NIVISION process visualization software.Â With the help of MultiCONT, different useful functions can be achieved such as configuring and optimizing the measurement or displaying the special echo map of the process environment. \u003ch3\u003eEasy Process Control with EasyTREK Series Level Sensors for Liquids\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e With the help of the SAP-200 plug-in display a full-parameter programming can be accomplished, the parameters of measurement and output can be set using the alphanumeric display module. The large LCD display displays the measured values in numerical and bar graph form. The display features indication for the infrared communication (IrDA) port which provides possibility for logger readout, diagnostics and software upgrade. The MultiCONT multichannel process controller \/ display unit is able to visualize the Echo Map. The Echo Map feature helps to detect false reflections and aids the optimization of the measurement configuration. \u003ch3\u003eEasyTREK for Liquids Ultrasonic Level Transmitter Specifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e11-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 176ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e(absolute): 7.5-43.5 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e0.49-59 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART, relay\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1\" BSP, 1.5\" and 2\" NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, INMETRO, UKCA Ex\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eEasyTREK Ultrasonic Level Transmitter for Liquids Model Line Up\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eEasyTREK\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eSP-500\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eSP-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSystem\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e2-wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eÂ± (0.1% of measured distance +0.025% of range) or Â± (0.05% of range), whichever is greater\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eÂ± (0.2% of measured distance +0.05% of range)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eDepending on the measured distance: \u0026lt;6.5 ft: 0.04 in, 6.5-16.5 ft: 0.075 in, 16.5-33 ft: 0.2 in, \u0026gt;33 ft: 0.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAnalog\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e4-20 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eRelay\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eSPDT, 30 V DC, 1 A DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital Communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eHART 7\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eHART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e-22 to 176ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePressure \u003cem\u003e(Absolute)\u003c\/em\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e0.5-3 bar; 7.25-43.5 psi\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower Supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e11 â 36 V DC\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e12 â 36 V DC \/ 48 â 720 mW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical Protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePP or PVDF same as the transducer material\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003ePolypropylene (PP) or (PVDF) same as the transducer material; In case of Teflon (PTFE) transducer the housing material is PP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSealing\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eIn case of PP transducer: EPDM; all the other transducers: FPM (Viton)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical Connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e4x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) (relay version: 7x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.25 inch cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eExplosion Protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eNone\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eSee: âEx Certifiedâ table below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e1.8-2.65 lb\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e2.65-4.4 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e\u003csup\u003e(1)\u003c\/sup\u003e under optimum conditions and stabilized transducer temperature \u003c\/em\u003e \u003ch3\u003eEx Certified EasyTREK Ultrasonic Level Transmitters\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEasyTREK SP-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProtection Type\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIntrinsically safe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eEx Marking (\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e)\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eII 1 G Ex ia IIB T6...T5 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIntrinsically Safe Data\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eCi â¤ 28 nF, Li â¤ 200 Î¼H, Ui â¤ 30 V, Ii â¤ 140 mA, Pi â¤ 1 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-4 to 158ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eWith PP transducer: -4 to 158ËF; with PVDF transducer: -4 to 176ËF; Temperature class T6 with PTFE transducer: -22 to 194ËF; Temperature class T5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical Connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e6 x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e shielded Ã6 mm cable\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of EasyTREK Ultrasonic Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e of most liquids and slurries\u003c\/li\u003e \u003cli\u003eflammable liquids and corrosive chemicals\u003c\/li\u003e \u003cli\u003eagriculture\u003c\/li\u003e \u003cli\u003econstruction materials\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical and petrochemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epaper mill\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003evapor, fume, mixing blades, and light foam\u003c\/li\u003e \u003cli\u003elevel measurement in basins, wells, sumps, lift-stations\u003c\/li\u003e \u003cli\u003elevel measurement of hydrocarbons, acids, aggressive liquids, any water based medium\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878364700803,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/liquids-nivelco-easy-trek-tank-monitoring-compact-ultrasonic-level-transmitter-sensor-for-liquid-measurement-SPA-360-4_37d160fb-bbaa-4d42-bb19-27875e653282.jpg?v=1763385170"},{"product_id":"integral-orifice-dp-flow-meter-run-assembly","title":"Integral Orifice DP Flow Meter Run Assembly","description":"The integral orifice meter run assembly is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/differential-pressure\/\"\u003edifferential pressure flow meter\u003c\/a\u003e for the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal water and wastewater industry\u003c\/a\u003e. They're specifically designed for smaller line sizes where the surface roughness, weld seams, and other geometrical imperfections have a relatively big influence on the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e uncertainty. This DP flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, features a minimum length of upstream and downstream pipe. Thus, it reduces additional uncertainties of the installation to a minimum. This DP flow meter is suitable for process and allocation measurement of gases and liquids such as viscous fluids, fluids with suspended solids, or fluids with gas entrainment. We offer the complete orifice assembly with orifice meter run, DP transmitter, valves, accessories, engineering, and documentation. This DP flow meter comes pressure tested and ready for commissioning. The meter run is available in various designs and is compliant with the requirements of the \u003ca href=\"https:\/\/www.iso.org\/standard\/79179.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eISO 5167\u003c\/a\u003e, such as pressure tap orientation and dimensions. It is fully machined and straightened to meet the highest dimensional expectations. If necessary, we can provide an additional calibration in line with the final operating conditions. We also supply special constructions such as redundant taps, integrated flow conditioner, certain paint specifications, or advanced NDTs from one source and in accordance with relevant standards (ISO 5167, etc.). \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-7060-dp-transmitter\/\"\u003e\u003cimg class=\"alignright wp-image-25936 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-optibar-dp-7060-differential-pressure-dp-flow-measurement-meter-process-solutions-corp.png\" alt=\"KROHNE-optibar-dp-7060-differential-pressure-dp-flow-measurement-meter-process-solutions-corp\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e \u003ch3\u003eOPTIBAR DP Flow Meter\u003c\/h3\u003e The sophisticated \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-7060-dp-transmitter\/\"\u003eOPTIBAR DP 7060\u003c\/a\u003e and the compact \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-3050-dp-pressure-transmitter\/\"\u003eOPTIBAR DP 3050\u003c\/a\u003e DP transmitters are the perfect companion for this DP flow meter solution. They are 3D linearized and ensure advanced performance even at high static pressures. Furthermore, the OPTIBAR DP series has outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations. \u003ch3\u003eFeatures of the Integral Orifice DP Flow Meter Run Assembly\u003c\/h3\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003estandardized calibrated orifice assembly for high accuracy requirements\u003c\/li\u003e \u003cli\u003edesign according to ISO 5167 as well as ISO TR 15377 from DN15 to DN100 (0.5 to 4\"), other sizes and designs on request\u003c\/li\u003e \u003cli\u003eelimination of additional uncertainties due to installation effects\u003c\/li\u003e \u003cli\u003elow TCO (Total Cost of Ownership) due to reduced engineering, commissioning, and installation costs\u003c\/li\u003e \u003cli\u003ereduced need for recalibration in the field through advanced 3-D linearized OPTIBAR DP transmitters\u003c\/li\u003e \u003cli\u003ecomplete DP flow meter solution with orifice meter run, manifold, DP transmitter, sizing, and documentation from a single source\u003c\/li\u003e \u003cli\u003eredundancy available (1oo2, 2oo3)\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART 7\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION fieldbus\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\u003c\/a\u003e communication options\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSIL 2\/3 certified versions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eEx ia, Ex d approvals\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of Differential Pressure Flow Meters\u003c\/h3\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eDP flow measurement in applications with small pipe diameters\u003c\/li\u003e \u003cli\u003eprocess measurement\u003c\/li\u003e \u003cli\u003eallocation measurement\u003c\/li\u003e \u003cli\u003ecustody transfer (CT) as well as fiscal measurement\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364831875,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optibar-7060-dp-flow-meter-Integral-orifice-meter-run-assembly-process-solutions-corp.png?v=1763385176"},{"product_id":"optiflux-2050-for-water-flow-measurement","title":"OPTIFLUX 2050 for Water Flow Measurement","description":"The OPTIFLUX 2050 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flowmeter (magmeter)\u003c\/a\u003e for basic and advanced water \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewastewater and municipal water applications\u003c\/a\u003e. It is suitable for all cost-effective measurements where extremely high accuracy, extensive diagnostics, or a wide range of communication options are not a priority. This magmeter has a wide diameter range: DN25 to DN1200 (1 to 48\"). In addition, this magmeter for water flow measurement offers all available approvals for drinking water. The extra isolation of its electronics as well as its special housing makes the OPTIFLUX 2050, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, particularly suitable for use in areas with extreme humidity. \u003cimg class=\"alignright wp-image-25908 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas\" width=\"627\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003eflange: DN25 to DN1200 (1 to 48\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e4-20 mA, pulse, frequency, status, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003erugged liners suitable for any water and wastewater application\u003c\/li\u003e \u003cli\u003eproven and unsurpassed lifetime, huge installation base\u003c\/li\u003e \u003cli\u003edrinking water approvals such as KTW, KIWA, DVGW, ACS, NSF, WRAS\u003c\/li\u003e \u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e \u003cli\u003ecompliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, as well as EN 14154)\u003c\/li\u003e \u003cli\u003eeasy installation and commissioning as well as maintenance-free\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2050 also features a full bore design with wear resistant liner materials. Installation in measurement chambers subject to (constant) flooding is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. This magmeter for water flow measurement comes with current output (including HART) and active pulse\/frequency output in addition to Modbus. Furthermore, operators can carry out a full on-site verification of the OPTIFLUX 2050 without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2050 Magmeter for Water Flow Measurement*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP68 rating\u003c\/a\u003e electronics for use in areas with extreme humidity and chances of flooding\u003c\/li\u003e \u003cli\u003estandard wet calibration\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner: excellent chemical resistance\u003c\/li\u003e \u003cli\u003esignal converter with display or as blind version\u003c\/li\u003e \u003cli\u003etamper proof, fully welded construction, also available in customer specific constructions\u003c\/li\u003e \u003cli\u003efull bore design: no moving parts, no wear, no pressure loss\u003c\/li\u003e \u003cli\u003estandard in house wet calibration of flow sensors up to diameter DN3000\u003c\/li\u003e \u003cli\u003eon-site verification of flowmeter with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses for the OPTIFLUX 2050 for Water Flow Measurement\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eall simple municipal water as well as wastewater applications\u003c\/li\u003e \u003cli\u003eabstraction and irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation and treatment systems\u003c\/li\u003e \u003cli\u003ewater purification and desalination\u003c\/li\u003e \u003cli\u003erevenue metering or billing leakage detection\u003c\/li\u003e \u003cli\u003eirrigation as well as cooling water\u003c\/li\u003e \u003cli\u003esewage and sludge\u003c\/li\u003e \u003cli\u003esea water\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364864643,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Wastewater-Flow-Measurement-Process-Solutions-Corp.png?v=1763385178"},{"product_id":"optiflux-1300-magnetic-flow-meter","title":"OPTIFLUX 1300 Magnetic Flow Meter","description":"The OPTIFLUX 1300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, with a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact\u003c\/a\u003e, lightweight wafer-style design. This magnetic flow meter is an economical solution for applications with conductive liquids (â¥ 5 Î¼S\/cm) in addition to higher solid content (up to 70%). In comparison with the OPTIFLUX 1100, the OPTIFLUX 1300, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, offers better accuracy. Furthermore, this \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e meets the demands of many applications in the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal and wastewater industry\u003c\/a\u003e. This magnetic flow meter is also a preference in dosing systems, compact skids, chemical handling systems, or pump and firefighting systems. \u003cimg class=\"alignright wp-image-25895 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas.jpg\" alt=\"KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas\" width=\"406\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003elightweight as well as compact for easy handling and space saving installation\u003c\/li\u003e \u003cli\u003eaffordable price\u003c\/li\u003e \u003cli\u003eexcellent chemical resistance\u003c\/li\u003e \u003cli\u003eno pressure loss\u003c\/li\u003e \u003cli\u003einsensitive to vibrations\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 1300 features a reinforced PFA liner as well as \u003ca href=\"https:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy\u003c\/a\u003e electrodes that guarantee excellent chemical resistance and a large temperature range up to 248ËF (120ËC). This EMF has no internal moving parts, does not require maintenance, and is also insensitive to vibrations. It comes with various digital communication options and approvals for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e. Furthermore, operators can use the OPTICHECK service tool for full on-site verification of this flow meter without process interruption. \u003ch3\u003eFeatures of the OPTIFLUX 1300 Magnetic Flow Meter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turndown ratio: 1000:1)\u003c\/li\u003e \u003cli\u003elightweight and compact wafer-style (\"sandwich\") design for space saving installation\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.3% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003ereinforced PFA liner: smooth surface, excellent chemical resistance\u003c\/li\u003e \u003cli\u003epipe cross-section without restrictions for slurries with non abrasive solid particles\u003c\/li\u003e \u003cli\u003eno internal moving parts or maintenance requirements\u003c\/li\u003e \u003cli\u003eon-site verification of this magnetic flow meter via OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of a Magnetic Flow Meter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral use in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal as well as wastewater applications\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003emore demanding water applications such as potable water, raw water, wastewater, salt water, heated and cooled water\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer)\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation in addition to treatment systems\u003c\/li\u003e \u003cli\u003edosing systems, filtration systems, and also pump control\u003c\/li\u003e \u003cli\u003ewater flow monitoring\u003c\/li\u003e \u003cli\u003eheat transfer and cooling systems\u003c\/li\u003e \u003cli\u003eviscous flows such as mud, slurry, sludge, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364897411,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optiflux-1300-magnetic-flow-meter-municipal-water-wastewater-flow-measurement-process-solutions-corp.png?v=1763385180"},{"product_id":"pr-7501-field-mounted-temperature-transmitter","title":"PR 7501 Field-Mounted Temperature Transmitter, Aluminum Housing, Safe Area","description":"\u003cp\u003eThe PR 7501 Field-Mounted Temperature Transmitter is a robust industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for accurate and reliable temperature measurement in demanding process environments. Ideal for direct field installation, the 7501, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/7500\/field-mounted-hart-temperature-transmitter-7501\/\" title=\"PR electronics 7501 Field-Mounted Temperature Transmitter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports a wide range of sensor inputs including RTD, thermocouple (TC), linear resistance, as well as bipolar mV. Furthermore, the PR 7501 converts inputs into a standardized 4-20 mA output with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 communication, fully backward compatible with HART 5 systems for advanced diagnostics and configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0, 90, 180, and 270 degree position adjustments.\u003c\/li\u003e\n\u003cli\u003eMonitoring, programming, and diagnostics view.\u003c\/li\u003e\n\u003cli\u003eExtensive diagnostics with flashing red or white backlight.\u003c\/li\u003e\n\u003cli\u003eSupports 7 languages.\u003c\/li\u003e\n\u003cli\u003eThis product features an aluminum housing and is suitable for use in safe areas.\u003c\/li\u003e\n\u003cli\u003eA \u003ca title=\"PR electronics 7501 Field-Mounted Temperature Transmitter with Stainless Steel Housing\" href=\"https:\/\/www.psctexas.shop\/products\/pr-7501-field-mounted-temperature-transmitter-stainless-steel\"\u003e316 stainless steel housing PR 7501\u003c\/a\u003e is also available.\u003c\/li\u003e\n\u003cli\u003eAn \u003ca href=\"https:\/\/www.psctexas.shop\/products\/pr-7501-field-mounted-ex-temperature-transmitter\" title=\"PR electronics 7501 Field-Mounted Ex Temperature Transmitter for Hazardous Areas\"\u003eintrinsically safe PR 7501\u003c\/a\u003e is also available for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 7501 features certification for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 7501 Field-Mounted Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 7501 can feature a high-definition local operator interface (LOI) with three optical buttons and a selectable red or white backlight. The LOI on the PR 7501 Field-Mounted Temperature Transmitter simplifies in-field setup, monitoring, and troubleshooting without opening the enclosure. Its rugged aluminum housing meets global safety standards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43 and NE89. \u003c\/li\u003e\n\u003cli\u003eUsers can change the HART protocol revision to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe PR 7501 excels in demanding industrial use, offering programmable response times, exceptional signal-to-noise performance, as well as support for individual, differential, or average temperature measurement from up to two sensors. The PR 7501 Field-Mounted Temperature Transmitter supports for up to 63 devices in a multidrop HART network. Furthermore, it offers comprehensive diagnostics including flashing backlight indicators, ensuring precise process control and reducing downtime. Whether in service in chemical processing, energy production, or heavy industrial automation, the PR 7501 delivers unmatchable temperature monitoring performance and operational reliability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration via the optional LOI through PR guided menu.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"PReset Programming Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset\u003c\/a\u003e and HART modem.\u003c\/li\u003e\n\u003cli\u003eHHC, DCS, or AMS via HART.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe PR 7501 provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eMounting on 1.5-2\" pipe bracket or on wall \/ bulkhead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eConfiguration Options\u003c\/h2\u003e\n\u003ch4\u003eInterface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLocal Operator Interface\n\u003cul\u003e\n\u003cli\u003e3 optical buttons (up, down, and enter) + local display.\u003c\/li\u003e\n\u003cli\u003eDynamically adaptive to wear or accumulation of dirt.\u003c\/li\u003e\n\u003cli\u003eImmune to interference from ambient light sources.\u003c\/li\u003e\n\u003cli\u003eUseable with or without gloves.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLocal Display Only \n\u003cul\u003e\n\u003cli\u003eFor readout of process values and diagnostics.\u003c\/li\u003e\n\u003cli\u003eExtensive diagnostics with flashing red or white backlight.\u003c\/li\u003e\n\u003cli\u003eSupports 7 languages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBlind Cover\n\u003cul\u003e\n\u003cli\u003eNo Display or Local Operator Interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTransmitter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYes - product arrives with transmitter.\u003c\/li\u003e\n\u003cli\u003eNo - includes a connection kit for connecting separate transmitter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7501-Field-Mounted-Temperature-Transmitter-PR-electronics-Rugged-Temperature-Sensor-Signal-Conditioning-Temp-RTD-Thermocouple-Transmitter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770308667\" alt=\"PR-7501-Field-Mounted-Temperature-Transmitter-PR-electronics-Rugged-Temperature-Sensor-Signal-Conditioning-Temp-RTD-Thermocouple-Transmitter-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3: Local Operator Interface (display + buttons) \/ 1: Yes","offer_id":46477877149827,"sku":"7501A3xxx11x","price":890.0,"currency_code":"USD","in_stock":true},{"title":"3: Local Operator Interface (display + buttons) \/ 2: No (comes with a connection kit)","offer_id":46477877182595,"sku":"7501A3xxx21x","price":700.0,"currency_code":"USD","in_stock":true},{"title":"2: Display (only) \/ 1: Yes","offer_id":46477877084291,"sku":"7501A2xxx11x","price":804.0,"currency_code":"USD","in_stock":true},{"title":"2: Display (only) \/ 2: No (comes with a connection kit)","offer_id":46477877117059,"sku":"7501A2xxx21x","price":613.0,"currency_code":"USD","in_stock":true},{"title":"1: None - Blind Cover \/ 1: Yes","offer_id":46477877018755,"sku":"7501A1xxx11x","price":669.0,"currency_code":"USD","in_stock":true},{"title":"1: None - Blind Cover \/ 2: No (comes with a connection kit)","offer_id":46477877051523,"sku":"7501A1xxx21x","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7501-Field-Mounted-Temperature-Transmitter-PR-electronics-Aluminum-Housing-Signal-Converter-RTD-Thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770310249"},{"product_id":"pr-6437d-din-rail-ex-temperature-transmitter","title":"PR 6437D DIN-Rail Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 6437D DIN-Rail Ex Temperature Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and also process measurement in automation systems. The 6437D, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, offers flexible sensor support including RTD, thermocouple (TC), bipolar mV, linear resistance, and potentiometer inputs. As a result, the PR 6437D delivers accurate 4-20 mA output with \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 communication support for advanced diagnostics, remote configuration, and data access. Its wide compatibility makes this \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e ideal for integration with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management software in manufacturing, energy, chemical processing, as well as HVAC environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of thermocouple and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eIdeal for critical applications requiring superior accuracy and\/or sensor redundancy as well as drift detection.\u003c\/li\u003e\n\u003cli\u003eThe 6437D is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6400\/2-wire-hart-7-temperature-transmitter-6437d\/\" title=\"PR electronics 6437D Ex DIN-Rail Temperature Transmitter\" target=\"_blank\"\u003ePR 6437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6437D DIN-Rail Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6437D DIN-Rail Ex temperature transmitter supports single or true dual inputs with sensor redundancy and drift detection. Thus, the 6437D ensures reliable measurement and improves uptime, even in critical applications. Dual input mapping options allow dynamic reporting of average, differential, minimum\/maximum, and other process variables for enhancing control as well as analysis. This DIN-rail temperature transmitter features programmable damping (0-60s) and excellent signal-to-noise performance to deliver stable outputs under varying conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter, accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime. \u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example: dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span as well as ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen in addition to custom linearization. \u003c\/li\u003e\n\u003cli\u003eProgrammable input limits with runtime metering ensure maximum process traceability and also provide sensor out of range protection. \u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eFailure rates for 6437xxSx correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eAble to withstand demanding industrial environments, the PR 6437D offers 2.5 kVAC galvanic isolation, complies with NAMUR NE21\/NE43\/NE44\/NE89, and is also fully assessed to IEC 61508 SIL 2\/3. As a result, the PR 6437D \u003cmeta charset=\"utf-8\"\u003eDIN-Rail Ex Temperature Transmitter is suitable for safety-critical systems. With up to 84 channels per meter on DIN-rail mounts as well as configuration via HART or PR Loop Link, this transmitter combines precision, connectivity, and reliability for modern process control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 inputs per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via \u003ca rel=\"noopener\" title=\"PReset Programming Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset\u003c\/a\u003e using the PR 5909 Loop Link \/\u003ca rel=\"noopener\" title=\"HART Protocol\" href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\"\u003eHART\u003c\/a\u003e modem, or by Asset Management tool, for example: \u003ca rel=\"noopener\" title=\"PACTware Programming Software\" href=\"https:\/\/pactware.com\/\" target=\"_blank\"\u003ePactware\u003c\/a\u003e, AMS, HART communicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC.jpg?v=1770236244\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; margin-bottom: 16px; float: none;\" alt=\"PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-P.jpg?v=1770236267\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367355011,"sku":"6437D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437D-DIN-Rail-Temperature-Transmitter-PR-electronics-HART-temp-sensor-industrial-temperature-converter-Process-Solutions-Texas.jpg?v=1770237417"},{"product_id":"pr-5437-hart-7-temperature-transmitter","title":"PR 5437 HART 7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5437 HART 7 Temperature Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437 Series, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 5437 Series are galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437A HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437a\/\" target=\"_blank\"\u003ePR 5437A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437B HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437b\/\" target=\"_blank\"\u003ePR 5437B\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437D HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437d\/\" target=\"_blank\"\u003ePR 5437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437 HART 7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437 HART 7 Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437 maximizes uptime and simplifies maintenance planning. The PR 5437 Series features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437 Series ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437 HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461156982915,"sku":"5437A1--","price":542.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157015683,"sku":"5437A1S-","price":579.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157048451,"sku":"5437A1-M","price":568.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157081219,"sku":"5437A1SM","price":605.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157113987,"sku":"5437A2--","price":605.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157146755,"sku":"5437A2S-","price":645.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157179523,"sku":"5437A2-M","price":635.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157212291,"sku":"5437A2SM","price":669.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461157245059,"sku":"5437B1--","price":597.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157277827,"sku":"5437B1S-","price":635.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157310595,"sku":"5437B1-M","price":623.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157343363,"sku":"5437B1SM","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157376131,"sku":"5437B2--","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157408899,"sku":"5437B2S-","price":695.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157441667,"sku":"5437B2-M","price":688.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157474435,"sku":"5437B2SM","price":723.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461157507203,"sku":"5437D1--","price":597.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157539971,"sku":"5437D1S-","price":638.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157572739,"sku":"5437D1-M","price":623.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157605507,"sku":"5437D1SM","price":663.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157638275,"sku":"5437D2--","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157671043,"sku":"5437D2S-","price":695.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157703811,"sku":"5437D2-M","price":688.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157736579,"sku":"5437D2SM","price":723.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437A-HART-Temperature-Transmitter-PR-electronics-signal-isolation-temperatuer-transmitter-process-solutions-texas.jpg?v=1770052636"},{"product_id":"pr-5437b-2-wire-hart-temperature-transmitter","title":"PR 5437B 2-wire HART Temperature Transmitter","description":"\u003cp\u003eThe PR 5437B 2-wire HART Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437B, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eThe 5437B is galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features multiple certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437b\/\" title=\"PR electronics 5437B HART 7 Temperature Transmitter\" target=\"_blank\"\u003ePR 5437B\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437B 2-wire HART Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437B 2-wire HART Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437B maximizes uptime and simplifies maintenance planning. The PR 5437B features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437B ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437B HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367420547,"sku":"5437B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-5437B-5437D-hazardous-area-temp-sensor-process-solutions-corp-psc-texas.jpg?v=1770052636"},{"product_id":"pr-5437d-hart-7-temperature-transmitter","title":"PR 5437D HART 7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5437D HART 7 Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437D, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 5437D are galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437d\/\" title=\"PR electronics 5437D HART 7 Temperature Transmitter\" target=\"_blank\"\u003ePR 5437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437D HART 7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437D HART 7 Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437D maximizes uptime and simplifies maintenance planning. The PR 5437D features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437D ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437D HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367453315,"sku":"5437D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-5437B-5437D-hazardous-area-temp-sensor-process-solutions-corp-psc-texas.jpg?v=1770052636"},{"product_id":"pr-3113-hart-temperature-converter","title":"PR 3113 HART Temperature Converter","description":"\u003cp\u003ePR Electronics 3113 HART Temperature Converter is a high-performance, \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e temperature conversion module designed for demanding industrial measurement environments. This compact yet powerful HART \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e accurately transforms signals from standard Pt100 RTDs and J\/K thermocouples into isolated analog current and \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 digital outputs, making the 3113, from \u003ca title=\"PR electronics 3113 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/hart-temperature-converter-3113\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ideal for integration with modern control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3113 HART temperature converter measures a standard Pt100, TC J and K temperature sensor and provides an isolated active analog current and HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 3 port isolation provides surge suppression and protects the control system from transients and noise.\u003c\/li\u003e\n\u003cli\u003eThe 3113 can mount in the safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003ePR 3113 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt with exceptional precision, better than 0.05 % of span, the 3113 ensures reliable, repeatable temperature measurement critical to process control, quality assurance, and safety systems. Its selectable internal or external cold junction compensation and switchable response time (from a rapid 60 ms up to 60 s) provide flexibility across diverse applications.\u003c\/p\u003e\n\u003cp\u003eEngineered with a slimline 6.1 mm housing, this HART temperature converter maximizes space efficiency on DIN rails, thus allowing up to 163 units per meter without gaps. Rugged galvanic isolation and robust EMC performance safeguard your system from electrical noise and transient surges, while compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 standards supports stable operation even in harsh industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly powered by 24 VDC (±30%) via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eA 60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 3113 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eA visible green LED indicates operational status of the unit and the input sensor.\u003c\/li\u003e\n\u003cli\u003eAll terminals are protected against overvoltage and polarity error. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eInstallation and configuration are effortless with DIP-switch settings for over 1,000 factory-calibrated temperature ranges and selectable HART modes, thus offering full read-write access for advanced device setup. Suitable for safe areas as well as Zone 2 \/ Div. 2 hazardous locations, the PR electronics 3113 delivers precision, flexibility, and reliability in a compact, industrial-grade package.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units to mount per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas.jpg?v=1768842513\" alt=\"PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3113: Supply via Power Rail Connector \/ Terminals","offer_id":46379828576387,"sku":"3113","price":304.0,"currency_code":"USD","in_stock":true},{"title":"3113-N: Supply via Terminals","offer_id":46379828609155,"sku":"3113-N","price":304.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-rtd-pt100-temp-signal-converter-process-solutions-corp-texas.jpg?v=1768842546"},{"product_id":"pr-3337-hart-temperature-converter","title":"PR 3337 HART Temperature Converter","description":"\u003cp\u003eThe PR 3337 HART Temperature Converter is a high-performance \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e ideal for industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e, automation, and instrumentation systems where accurate temperature measurement and digital communication are essential. This \u003ca title=\"HART Protocol\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e-compatible temperature converter accepts standard Pt100 RTD and thermocouple (TC J \u0026amp; K) sensor inputs. The 3337, from \u003ca title=\"PR electronics 3337 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/hart-temperature-converter-loop-powered-3337\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, then provides both an \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e analog 4–20 mA output and a digital HART 7 communication signal for advanced diagnostics and configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3337 HART temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated passive analog current as well as a HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 2-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection from over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in safe areas or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3337 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 3337 HART Temperature Converter delivers excellent conversion accuracy, better than 0.05 % of span, as well as selectable fast or damped response times (60 ms\/60 s). Thus, the 3337 is ideal for responsive feedback in industrial control loops. Its robust 2-port galvanic isolation (2.5 kVAC) eliminates ground loops, suppresses noise and transients, and protects sensitive PLC, DCS, and SCADA inputs.\u003c\/p\u003e\n\u003cp\u003eFeaturing more than 1,000 pre-calibrated temperature ranges and selectable internal\/external cold junction compensation, this loop-powered HART temperature converter offers flexible configuration with DIP switches or full HART read\/write capability. The slim 6.1 mm DIN-rail housing supports high-density panel mounting, thus saving space in control cabinets. Furthermore, rugged terminal protection guards against over-voltage, polarity reversal, and short circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop-powered by 6.2 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eSelectable internal \/ external CJC.\u003c\/li\u003e\n\u003cli\u003e60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe PR 3337 meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for safe areas and featuring certification for Zone 2 \/ Division 2 and marine applications, the 3337 ensures reliable performance across industrial, energy, wastewater, and chemical process environments. The 3337 delivers accurate temperature conversion with modern HART communication support.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas.jpg?v=1768941910\" alt=\"PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367715459,"sku":"3337","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-temperature-converter-pr-electronics-temp-conversion-signal-process-solutions-corp-psc-texas.jpg?v=1768941929"},{"product_id":"pr-5335-hart-temperature-transmitter","title":"PR 5335 HART Temperature Transmitter","description":"\u003cp\u003eThe PR 5335 HART Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate process monitoring and advanced communication. The 5335, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is compatible with RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), ohmic, and mV inputs. Furthermore, this versatile \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e linearizes temperature signals and outputs a reliable 4-20 mA signal with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART 5 communication protocol\u003c\/a\u003e for flexible diagnostics and device configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or thermocouple (TC) sensor.\u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 transmitters to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eModels in the 5335 Series are galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5335a\/\" title=\"PR electronics 5335A HART Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR 5335A\u003c\/a\u003e is certified for hazardous areas Zone 2 \/ Div 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5335d\/\" title=\"PR electronics 5335D HART Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR 5335D\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5335 HART Temperature Transmitter for Thermocouple from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for modern industrial environments, the PR 5335 HART Temperature Transmitter offers extremely high measurement accuracy and programmable sensor error values. In addition, this head-mounted temperature transmitter performs continuous safety checks that improve reliability in demanding applications. With HART capability, users can connect up to 15 transmitters on a single digital 2-wire signal. Thus, the PR 5335 enables remote calibration, real-time diagnostics, and enhances process control without interrupting the analog signal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5335 Series to measure temperatures within all ranges defined by the norms. \u003c\/li\u003e\n\u003cli\u003eThe RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe 5335 Series provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for DIN form B sensor head mounting, this loop-powered transmitter is ideal for HVAC, energy, automation, and manufacturing systems where dependable temperature measurement is essential. The 5335 Series also provides the necessary failure data for SIL 2 applications per IEC 61508\/61511 and sensor error detection per NAMUR standards. Whether upgrading existing installations or specifying new industrial instrumentation, the PR 5335 Series delivers accurate, configurable, and communication-ready temperature measurement for today’s process systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head.\u003c\/li\u003e\n\u003cli\u003eModel 5335A is also suitable for DIN rail mounting with the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas.jpg?v=1769794810\" alt=\"PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5335A: General Purpose; Zone 2 \/ Div 2; ATEX; CSA; IECEx","offer_id":46450704973955,"sku":"5335A","price":488.0,"currency_code":"USD","in_stock":true},{"title":"5335D: Zone 0; 1; 2; 21; 22; M1 \/ Div 1; Div 2; ATEX; CSA; FM: IECEx","offer_id":46450705006723,"sku":"5335D","price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-A-HART-Temperature-Transmitter-PR-electronics-temperature-sensor-for-thermocouple-RTD-mV-input-4-20-ma-signal-conditioner-process-solutions-psc-texas.jpg?v=1769795265"},{"product_id":"pr-5335d-ex-hart-temperature-transmitter","title":"PR 5335D Ex HART Temperature Transmitter","description":"\u003cp\u003eThe PR 5335D Ex HART Temperature Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for accurate process monitoring and advanced communication. The 5335D, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is compatible with RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), ohmic, and mV inputs. Furthermore, this versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e linearizes temperature signals and outputs a reliable 4-20 mA signal with integrated \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART 5 communication protocol\u003c\/a\u003e for flexible diagnostics and device configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or thermocouple (TC) sensor.\u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 transmitters to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5335D Ex HART Temperature Transmitter for Thermocouple from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for modern industrial environments, the PR 5335D Ex HART Temperature Transmitter offers extremely high measurement accuracy and programmable sensor error values. In addition, this head-mounted temperature transmitter performs continuous safety checks that improve reliability in demanding applications. With HART capability, users can connect up to 15 transmitters on a single digital 2-wire signal. Thus, the PR 5335D enables remote calibration, real-time diagnostics, and enhances process control without interrupting the analog signal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5335D to measure temperatures within all ranges defined by the norms. \u003c\/li\u003e\n\u003cli\u003eThe RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe 5335D provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for DIN form B sensor head mounting, this loop-powered transmitter is ideal for HVAC, energy, automation, and manufacturing systems where dependable temperature measurement is essential. The 5335D also provides the necessary failure data for SIL 2 applications per IEC 61508\/61511 and sensor error detection per NAMUR standards. Whether upgrading existing installations or specifying new industrial instrumentation, the PR 5335D delivers accurate, configurable, and communication-ready temperature measurement for today’s process systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas.jpg?v=1769794810\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368043139,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-D-NAMUR-temperature-sensor-HART-5-Protocol-Process-Solutions-PSC-Texas.jpg?v=1769795265"},{"product_id":"pr-5337-hart-5-7-temperature-transmitter","title":"PR 5337 HART 5\/7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5337 HART 5\/7 Temperature Transmitter delivers precise, reliable temperature measurement in addition to advanced communication for demanding industrial applications. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART-enabled\u003c\/a\u003e transmitter supports a wide range of inputs, for example, RTD (Pt100, Ni100), thermocouple (TC), ohm, and bipolar mV signals. The 5337, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, converts linear process values into a stable 4-20 mA output with digital diagnostics. Perfect for modern \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e systems, the PR 5337 HART 5\/7 Temperature Transmitter allows users to select between HART 5 or HART 7 protocol. It enables up to 63 transmitters in a multidrop network with extended tag names, enhanced burst mode, trend logs, as well as event notifications for richer process insights.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature measurement\u003c\/a\u003e with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eModels in the 5337 Series are galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5337A HART 5\/7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337a\/\" target=\"_blank\"\u003ePR 5337A\u003c\/a\u003e is certified for hazardous areas Zone 2 \/ Div 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5337D HART 5\/7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337d\/\" target=\"_blank\"\u003ePR 5337D\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5337 HART 5\/7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThis rugged transmitter is suitable for use in general purpose or hazardous location installations and meets safety and performance standards including SIL-capable hardware and \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e EMC recommendations. Ideal for HVAC, energy, automation, manufacturing, and process industries, the PR 5337 HART 5\/7 Temperature Transmitter supports linearized temperature measurement, differential, or average readings from dual sensors, as well as conversion of resistance or mV signals to standard analog.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers can change the HART protocol revision configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe 5337 HART 5\/7 temperature transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 5337 Series HART transmitter ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eAdditionally, the PR 5337 meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eMountable in a DIN form B sensor head, the PR 5337 HART 5\/7 Temperature Transmitter also features continuous data integrity checks and flexible configuration via HART tools or PR Loop Link interfaces. The PR 5337 Series enhances control system performance with accurate measurement, robust communications, and seamless integration into modern industrial infrastructure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel PR 5337A is also suitable for DIN rail mounting via the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas.jpg?v=1769804950\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5337A: General Purpose; Zone 2 \/ Div 2; ATEX; CSA; IECEx","offer_id":46450805211267,"sku":"5337A","price":539.0,"currency_code":"USD","in_stock":true},{"title":"5337D: Zone 0; 1; 2; 21; 22; M1 \/ Div 1; Div 2; ATEX; CSA; FM; IECEx","offer_id":46450805244035,"sku":"5337D","price":593.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-A-HART-Temperature-Transmitter-PR-electronics-industrial-temperature-measurement-hart-protocol-process-solutions-texas.jpg?v=1769805616"},{"product_id":"pr-5337d-hart-5-7-ex-temperature-transmitter","title":"PR 5337D HART 5\/7 Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 5337D HART 5\/7 Ex Temperature Transmitter delivers precise, reliable temperature measurement in addition to advanced communication for demanding industrial applications. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART-enabled\u003c\/a\u003e transmitter supports a wide range of inputs, for example, RTD (Pt100, Ni100), thermocouple (TC), ohm, and bipolar mV signals. The 5337D, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337d\/\" title=\"PR electronics 5337D HART 5\/7 Ex Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, converts linear process values into a stable 4-20 mA output with digital diagnostics. Perfect for modern \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e systems, the PR 5337D HART 5\/7 Ex Temperature Transmitter allows users to select between HART 5 or HART 7 protocol. It enables up to 63 transmitters in a multidrop network with extended tag names, enhanced burst mode, trend logs, as well as event notifications for richer process insights.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature measurement\u003c\/a\u003e with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eThe 5337D is galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn addition, the 5337D also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5337D HART 5\/7 Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThis rugged transmitter is suitable for use in general purpose or hazardous location installations and meets safety and performance standards including SIL-capable hardware and \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e EMC recommendations. Ideal for HVAC, energy, automation, manufacturing, and process industries, the PR 5337D HART 5\/7 Ex Temperature Transmitter supports linearized temperature measurement, differential, or average readings from dual sensors, as well as conversion of resistance or mV signals to standard analog.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers can change the HART protocol revision configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe 5337D HART 5\/7 Ex temperature transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 5337D HART transmitter ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eAdditionally, the PR 5337D meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eMountable in a DIN form B sensor head, the PR 5337D HART 5\/7 Ex Temperature Transmitter also features continuous data integrity checks and flexible configuration via HART tools or PR Loop Link interfaces. The PR 5337D enhances control system performance with accurate measurement, robust communications, and seamless integration into modern industrial infrastructure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas.jpg?v=1769804950\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368108675,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-D-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-to-Analog-temperature-measurement-process-solutions-corp-psc-texas.jpg?v=1769805616"},{"product_id":"pr-6335-2-wire-hart-transmitter","title":"PR 6335 2-wire HART Transmitter","description":"\u003cp\u003eThe PR 6335 2-wire HART Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precise temperature and resistance \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in advanced process automation systems. The 6335 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), linear resistance, as well as mV inputs. Furthermore, this versatile transmitter converts sensor signals into a standardized 4-20 mA output with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication for efficient monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, as well as TC sensors. \u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance (RTD) or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 channels to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eModels in the 6335 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335A 2-wire HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335a\/\" target=\"_blank\"\u003ePR 6335A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335D 2-wire Ex HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335d\/\" target=\"_blank\"\u003ePR 6335D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6335 2-wire HART Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6335 offers HART 5 protocol support and galvanic isolation between input and output. Furthermore, the 6335 2-wire HART Transmitter delivers robust signal integrity and reliable data transmission even in electrically noisy industrial environments. This transmitter offers programmable response time (1-60s), sensor error detection compliance with \u003ca title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89, and cable compensation for 2-, 3-, or 4-wire configurations. Thus, the PR 6335 Series ensures accurate measurements with minimal wiring impact. With better than 0.05% accuracy of the selected range and support for differential or average temperature measurement, the 6335 Series fits a broad range of industrial applications including manufacturing, energy, chemical processing, HVAC, and automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6335 Series to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe PR 6335 2-wire HART Transmitter provides the necessary failure data (SFF and PFDAVG) for SIL applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in NAMUR NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple and use standard HART interfaces or the PR Loop Link communication tool. Thus, the PR 6335 2-wire HART Transmitter enables remote parameterization and real-time device insights for improving maintenance and uptime. With certification for installations in hazardous areas, this transmitter combines accuracy, connectivity, and durability for demanding industrial temperature measurement needs. \u003cmeta charset=\"utf-8\"\u003eInstallation is flexible, mountable vertically or horizontally on standard DIN rails with up to 84 channels per meter for high-density panel layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, users can mount up to 84 channels per meter. \u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225929\" alt=\"PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46470501695619,"sku":"6335A2A","price":514.0,"currency_code":"USD","in_stock":true},{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46470501728387,"sku":"6335A2B","price":917.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 1-Channel","offer_id":46470501761155,"sku":"6335D2A","price":561.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 2-Channel","offer_id":46470501793923,"sku":"6335D2B","price":1001.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-signal-isolation-temperature-transmitter-rtd-thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225948"},{"product_id":"pr-6335d-2-wire-hart-ex-transmitter","title":"PR 6335D 2-wire HART Ex Transmitter","description":"\u003cp\u003eThe PR 6335D 2-wire HART Ex Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for precise temperature and resistance \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal conversion\u003c\/a\u003e in advanced process automation systems. The 6335D, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335d\/\" title=\"PR electronics 6335D 2-wire HART Ex Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, supports RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), linear resistance, as well as mV inputs. Furthermore, this versatile transmitter converts sensor signals into a standardized 4-20 mA output with integrated \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e communication for efficient monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, as well as TC sensors. \u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance (RTD) or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 channels to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eThe 6335D is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, and features certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePR 6335D has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6335D 2-wire HART Ex Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6335D offers HART 5 protocol support and galvanic isolation between input and output. Furthermore, the 6335D 2-wire HART Ex Transmitter delivers robust signal integrity and reliable data transmission even in electrically noisy industrial environments. This transmitter offers programmable response time (1-60s), sensor error detection compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89, and cable compensation for 2-, 3-, or 4-wire configurations. Thus, the PR 6335D ensures accurate measurements with minimal wiring impact. With better than 0.05% accuracy of the selected range and support for differential or average temperature measurement, the 6335D fits a broad range of industrial applications including manufacturing, energy, chemical processing, HVAC, and automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6335D to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe PR 6335D 2-wire HART Ex Transmitter provides the necessary failure data (SFF and PFDAVG) for SIL applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in NAMUR NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple and use standard HART interfaces or the PR Loop Link communication tool. Thus, the PR 6335D 2-wire HART Ex Transmitter enables remote parameterization and real-time device insights for improving maintenance and uptime. With certification for installations in hazardous areas, this transmitter combines accuracy, connectivity, and durability for demanding industrial temperature measurement needs. \u003cmeta charset=\"utf-8\"\u003eInstallation is flexible, mountable vertically or horizontally on standard DIN rails with up to 84 channels per meter for high-density panel layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, users can mount up to 84 channels per meter. \u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225929\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368469123,"sku":"6335D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-D-2-wire-Ex-HART-Transmitter-PR-electronics-intrinsically-safe-temperature-transmitter-signal-isolation-Process-Solutions-PSC-Texas.jpg?v=1770226650"},{"product_id":"pr-6337-2-wire-hart-temperature-transmitter","title":"PR 6337 2-wire HART Temperature Transmitter","description":"\u003cp\u003eThe PR 6337 2-wire HART Temperature Transmitter is a highly adaptable industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and process measurement in advanced automation systems. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e is capable of supporting RTD, thermocouple (TC), linear resistance, and bipolar mV inputs. Furthermore, the 6337 Series, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, converts sensor signals into a standardized 4-20 mA output with integrated \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e communication (selectable HART 5 or HART 7), which enhances diagnostics, configuration, and remote device management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eModels in the 6337 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6337A 2-wire HART Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6337a\/\" target=\"_blank\"\u003ePR 6337A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6337D 2-wire HART Ex Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6337d\/\" target=\"_blank\"\u003ePR 6337D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003ePR 6337 2-wire HART Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for industrial control, energy, and manufacturing applications, this transmitter reliably measures individual, differential, or averaged temperature values from up to two sensors. The HART 7 protocol offers long tag names, event logging with time stamps, burst mode, and flexible device variable mapping. Thus, the PR 6337 2-wire HART Temperature Transmitter enables smarter process monitoring and seamless integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHART protocol revision can change by user configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong Tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe PR 6337 2-wire HART Temperature Transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511. \u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, the PR 6337 HART transmitter ensures top measurement performance in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 6337 meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 6337 meets key industrial standards, including NAMUR NE21, NE43, and NE89 EMC recommendations. Furthermore, the 6337 Series is assessed for use in SIL safety applications, ensuring dependable measurement performance. DIN-rail mounting supports high channel density (up to 84 channels\/meter), and users can perform configuration via standard HART interfaces or the PR 5909 Loop Link tool. The 6337 Series offers better than 0.05% accuracy, programmable response times (1-60s), as well as robust signal integrity in harsh electrical environments. In addition, the PR 6337 delivers precise, reliable temperature measurement for advanced industrial automation and safety-critical systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 channels per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas.jpg?v=1770232311\" alt=\"PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6337A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46471005208707,"sku":"6337A2A","price":514.0,"currency_code":"USD","in_stock":true},{"title":"6337A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46471005241475,"sku":"6337A2B","price":917.0,"currency_code":"USD","in_stock":true},{"title":"6337D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 1-Channel","offer_id":46471005274243,"sku":"6337D2A","price":618.0,"currency_code":"USD","in_stock":true},{"title":"6337D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 2-Channel","offer_id":46471005307011,"sku":"6337D2B","price":1105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-hart-protocol-temperature-measurement-Process-Solutions-Corp-PSC-Texas.jpg?v=1770233137"},{"product_id":"pr-6337d-2-wire-hart-ex-temperature-transmitter","title":"PR 6337D 2-wire HART Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 6337D 2-wire HART Ex Temperature Transmitter is a highly adaptable industrial \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and process measurement in advanced automation systems. This \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e is capable of supporting RTD, thermocouple (TC), linear resistance, and bipolar mV inputs. Furthermore, the 6337D Series, from \u003ca title=\"PR electronics 6337D 2-wire HART Ex Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6337d\/\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, converts sensor signals into a standardized 4-20 mA output with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication (selectable HART 5 or HART 7), which enhances diagnostics, configuration, and remote device management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eThe 6337D is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe PR 6337D has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003ePR 6337D 2-wire HART Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for industrial control, energy, and manufacturing applications, this transmitter reliably measures individual, differential, or averaged temperature values from up to two sensors. The HART 7 protocol offers long tag names, event logging with time stamps, burst mode, and flexible device variable mapping. Thus, the PR 6337D 2-wire HART Ex Temperature Transmitter enables smarter process monitoring and seamless integration with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHART protocol revision can change by user configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong Tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe PR 6337D 2-wire HART Ex Temperature Transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511. \u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, the PR 6337D HART transmitter ensures top measurement performance in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 6337D meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 6337D meets key industrial standards, including NAMUR NE21, NE43, and NE89 EMC recommendations. Furthermore, the 6337D is assessed for use in SIL safety applications, ensuring dependable measurement performance. DIN-rail mounting supports high channel density (up to 84 channels\/meter), and users can perform configuration via standard HART interfaces or the PR 5909 Loop Link tool. The 6337D offers better than 0.05% accuracy, programmable response times (1-60s), as well as robust signal integrity in harsh electrical environments. In addition, the PR 6337D delivers precise, reliable temperature measurement for advanced industrial automation and safety-critical systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 channels per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 25px; float: none;\" alt=\"PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas.jpg?v=1770232311\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368534659,"sku":"6337D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Ex-Temperature-Transmitter-PR-electronics-hazardous-area-temperature-sensor-industrial-temperature-measurement-process-solutions-PSC-Texas.jpg?v=1770233137"},{"product_id":"pr-9106b-ex-hart-transparent-repeater","title":"PR 9106B Ex HART Transparent Repeater","description":"\u003cp\u003eThe PR 9106B Ex HART Transparent Repeater is a high-performance signal repeater for industrial automation and process control applications where reliable, accurate communication is critical. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device delivers robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (2.6 kVAC) to protect sensitive instrumentation from electrical interference. As a result, the 9106B, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-repeater-9106b\/\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ensures consistent signal integrity, even in harsh environments. With support for active as well as passive mA inputs and outputs, the PR 9106B Ex HART Transparent Repeater seamlessly interfaces with 2-wire SMART transmitters and current sources while enabling bi-directional \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9106B is a 1- or 2-channel isolated 1:1 repeater barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eThe 9106B supplies 2-wire SMART transmitters and is also suitable for use as a 2-wire SMART current source.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater supports both \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" title=\"HART Protocol\" rel=\"noopener\" target=\"_blank\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN protocols and can transfer bi-directionally.\u003c\/li\u003e\n\u003cli\u003eFor duplication\/migration purposes, outputs can send to two different DCS,  \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLC\/HMI\u003c\/a\u003e, or any monitoring system. \u003c\/li\u003e\n\u003cli\u003eModels in the 9106B are galvanically isolated, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eThe PR 9106B can mount in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003eIn safety applications (SIL loops), model 9106BxBx is suitable for use as a splitter with the following output configuration:\n\u003cul\u003e\n\u003cli\u003eWhen using 9106BxBx in a SIL2 safety function, channel 1 is the safety loop.\u003c\/li\u003e\n\u003cli\u003eChannel 2 is suitable for any non-safety device.\u003c\/li\u003e\n\u003cli\u003eFor higher safety purposes (SIL 3), 9106BxBx can function as a splitter for SIL 3 loops.\u003c\/li\u003e\n\u003cli\u003eChannel 1 and 2 then connect to the same safety PLC, where channel 2 is a redundant diagnostic channel (for more information, consult the FMEDA Report and the Safety Manual).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9106B Ex HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing wide flexibility, the PR 9106B Ex HART Transparent Repeater can operate as a single-channel or dual-channel repeater. Furthermore, the 9106B includes a splitter function to duplicate a single input to two outputs, which is ideal for feeding multiple DCS, PLC, or HMI systems without signal degradation. Its fast response time (-5 ms) and high accuracy (better than ±0.1%) ensure real-time monitoring performance. Some models of the PR 9106B feature certification for use in SIL2\/SIL3 safety loops according to \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 and is suitable for safety-critical installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe detachable displays in the \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500 series\u003c\/a\u003e and the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage on input via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9106B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt;5 ms.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003e2-wire transmitter supply \u0026gt;16 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 9016 Series is compact, DIN-rail mountable, and compatible with optional detachable displays and status monitoring accessories. Furthermore, the PR 9106B Ex HART Transparent Repeater is an ideal choice for enhancing HART signal reliability and expanding system integration with minimal configuration effort.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePR 9106B devices can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solution.jpg?v=1770394665\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368764035,"sku":"9106B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-B-HART-Ex-Transparent-Repeater-PR-electronics-HART-Signal-Splitter-Repeater-Intrinsically-Safe-Barrier-Signal-Isolator-Process-Solutions-PSC-Texas.jpg?v=1770396175"},{"product_id":"pr-9107b-hart-ex-transparent-driver","title":"PR 9107B HART Ex Transparent Driver","description":"\u003cp\u003eThe PR 9107B HART Ex Transparent Driver is a high-performance industrial signal driver for precise control and reliable communication in process automation systems. The 9107B, from \u003ca title=\"PR electronics 9107B HART Ex Transparent Driver\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-driver-9107b\/\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is suitable for both single-channel and dual-channel applications. Furthermore, the PR 9107B delivers galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e 1:1 current driving capability, making it ideal for powering and controlling I\/P converters, \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e, and indicators in safe or \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e. Its bi-directional \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e transparency ensures seamless communication with HART-enabled field devices, thus allowing real-time diagnostics, configuration, and monitoring without signal loss or interference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperation and drive control of I\/P converters, valves, and indicators.\u003c\/li\u003e\n\u003cli\u003eOperation of \u003ca rel=\"noopener\" title=\"HART Protocol\" href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\"\u003eHART\u003c\/a\u003e devices is possible as the unit transmits HART communication signals bi-directionally.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e Series displays the process value for each channel and can also define high and low limits for detection of loop current level. If these limits are exceeded, the status relay will activate.\u003c\/li\u003e\n\u003cli\u003eDual channel versions can operate in signal splitter applications - 1 in and 2 out.\u003c\/li\u003e\n\u003cli\u003eThe 9107B is galvanically isolated, \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and features various certifications for use in hazardous areas as well as \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9107B HART Ex Transparent Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9107B HART Ex Transparent Driver features fast response times (\u0026lt; 5 ms), high load drive (725 Ω at 20 mA), and robust output line fault detection via status relay. Furthermore, the 9107B ensures dependable performance under industrial conditions. SIL 2 certification per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 attests to its suitability in safety-related systems where functional reliability is critical.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 4500 detachable displays as well as the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eA tag number can be defined for each channel.\u003c\/li\u003e\n\u003cli\u003eOutput line fault detection.\u003c\/li\u003e\n\u003cli\u003eIn the 1-channel version the status relay can be used as a simple limit switch.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9107B correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFor added flexibility, a detachable PR 4500 display provides local process value indication and configurable loop current limits with alarm output. Dual-channel versions support splitter functionality, delivering a single input to two outputs for expanded system integration. Compact and DIN-rail mountable, the PR 9107B HART Ex Transparent Driver blends safety, precision, and versatility. Thus, the 9107B optimizes control system architecture while enhancing operational uptime and HART communication continuity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 9107B can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions.jpg?v=1770400499\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368796803,"sku":"9107B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-Ex-HART-Transparent-Driver-PR-electronics-9107N-HART-Signal-Splitter-Isolated-Signal-Driver-Intrinsically-Safe-Process-Solutions-Corp-PSC-Texas.jpg?v=1770404383"},{"product_id":"pr-7908-backplane","title":"PR 7908 Backplane","description":"\u003cp\u003eThe PR 7908 Backplane is a robust, high-performance interface solution that streamlines the connection between PR 9000 \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e (I.S.) devices and standard automation systems such as \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and safety systems. This compact backplane provides a safe, organized wiring platform for up to eight System 9000 units. The 7908, from \u003ca title=\"PR electronics 7908 Backplane\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/7900\/backplane-7908\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports numerous signal types including AI (analog input), AO (analog output), DI\/DO (digital input\/output), and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e communication. Thus, the PR 7908 Backplane is perfect for efficient integration and diagnostics across industrial automation applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 7908 Backplane is a compact and robust solution that enables a safe and easy connection of PR system 9000 IS device signals into standard automation systems.\u003c\/li\u003e\n\u003cli\u003eStandard automation system cables and connectors link the backplane to the I\/O cards.\u003c\/li\u003e\n\u003cli\u003eThe backplane is ideal for Direct, Redundant, and Duplicate signaling including \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" title=\"HART Protocol\" rel=\"noopener\" target=\"_blank\"\u003eHART\u003c\/a\u003e I\/O System connectivity (HART MUX).\u003c\/li\u003e\n\u003cli\u003ePR 9000 Series devices \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolate\u003c\/a\u003e and convert AI, AO, DI, and DO signals coming from, or going to, the I.S. classified area, then routes those signals to a system automation I\/O card.\u003c\/li\u003e\n\u003cli\u003eThe PR 9000 Series maintains a SIL2\/SIL3 level of functional safety, even when mounting in the backplane solution.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 7916 Backplane for PR 9000 Series\" href=\"https:\/\/www.psctexas.shop\/products\/pr-7916-backplane-for-pr-9000-series\"\u003ePR 7916 Backplane\u003c\/a\u003e is also available and supports up to 16 modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 7908 Backplane from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt to withstand demanding environments, the PR 7908 Backplane features a rugged, high-end design with digital status outputs and LED indicators. As a result, the 7908 delivers real-time status feedback on connected devices and redundant \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003epower supplies\u003c\/a\u003e. Standard prefabricated I\/O cables make connection to I\/O cards simple, thus reducing installation time and minimizing wiring errors on complex panels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRobust, compact high-end design that holds eight (8) PR 9000 Series units.\u003c\/li\u003e\n\u003cli\u003eDigital output indicates status of PR 9000 devices and primary\/back-up power supplies.\u003c\/li\u003e\n\u003cli\u003eFlexible 24 VDC supply voltage and redundant power supply connection solution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOTE\u003c\/strong\u003e: PR 9000 Series modules are sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe backplane supports direct, redundant, and duplicate signaling, including HART I\/O (HART MUX) for advanced system communications. In addition, the PR 7908 Backplane maintains SIL2\/SIL3 functional safety levels when used with PR 9000 Series modules. With wide voltage and environmental tolerance, the PR 7908 ensures reliable, organized, and safe deployment of I.S. interface devices in process automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible horizontal\/vertical panel or wall mounting in the Safe or Zone 2 \/ Div 2 \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003ePR 9000 Series devices easily snap ON and OFF using piano keys, and devices can also be hot-swapped.\u003c\/li\u003e\n\u003cli\u003eTag number and ID labels easily mount and are read by the dedicated piano key spacer.\u003c\/li\u003e\n\u003cli\u003eWide temperature operation range: -4 to 140˚F (-20 to 60˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7908-Back-Plane-PR-electronics-Signal-Conditioning-Rack-PR-9000-Series-Power-Supply-Intrinsically-Safe-Mounting-Process-Solutions-Corp-PSC-Texas.jpg?v=1770330443\" alt=\"PR-7908-Back-Plane-PR-electronics-Signal-Conditioning-Rack-PR-9000-Series-Power-Supply-Intrinsically-Safe-Mounting-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"7908-ABBS8-A1A \/ ABB S800 Backplane: (8) 9106xxA or (8) 9113xA","offer_id":46488283152515,"sku":"7908-ABBS8-A1A","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-ABBS8-A1B \/ ABB S800 Backplane: (8) 9106xxB or (8) 9113xB","offer_id":46488283185283,"sku":"7908-ABBS8-A1B","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-ABBS8-B1C \/ ABB S800 Backplane: (8) 9107xA","offer_id":46488283218051,"sku":"7908-ABBS8-B1C","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-ABBS8-C1H \/ ABB S800 Backplane: (8) 9202xxB; 2-Channel","offer_id":46488283250819,"sku":"7908-ABBS8-C1H","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-HoExp-A1B \/ Honeywell Experion C300 CC-TAIX01\/11: (8) 9106xxB or (8) 9113xB","offer_id":46488283283587,"sku":"7908-HoExp-A1B","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-HoExp-B1B \/ Honeywell Experion C300 CC-TAOX01\/11: (8) 9107xB","offer_id":46488283316355,"sku":"7908-HoExp-B1B","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-HoRus-A1B \/ Honeywell RUSIO; (8) Universal 2-Channel Devices","offer_id":46488283349123,"sku":"7908-HoRus-A1B","price":568.0,"currency_code":"USD","in_stock":true},{"title":"7908-YoCen-A2B \/ Yokogawa Centum AAI141: (8) 9106xxB or (8) 9113xB","offer_id":46488283381891,"sku":"7908-YoCen-A2B","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-YoCen-B2F \/ Yokogawa Centum AAI841: (4) 9106xxB or (4) 9107xB or (4) 9113xB","offer_id":46488283414659,"sku":"7908-YoCen-B2F","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-YoPro-A2B \/ Yokogawa Prosafe SAI143: (8) 9106xxB or (8) 9113xB","offer_id":46488283447427,"sku":"7908-YoPro-A2B","price":460.0,"currency_code":"USD","in_stock":true},{"title":"7908-YoPro-D2H \/ Yokogawa Prosafe SDV144: (8) 9202xxB","offer_id":46488283480195,"sku":"7908-YoPro-D2H","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-YoPro-E2I \/ Yokogawa Prosafe SDV531: (8) 9203xxA","offer_id":46488283512963,"sku":"7908-YoPro-E2I","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-UNI-A1B \/ Universal Backplane: (8) Module; 8\/16-Channel","offer_id":46488283545731,"sku":"7908-UNI-A1B","price":474.0,"currency_code":"USD","in_stock":true},{"title":"7908-UNI-H1B \/ Universal Backplane: (8) Module; 8\/16-Channel with HART","offer_id":46488283578499,"sku":"7908-UNI-H1B","price":474.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7908-Backplane-Interface-Solutions-Intrinsically-Safe-PR-9000-Series-Signal-Conditioning-Mounting-Supply-Process-Solutions-Corp-PSC-Texas.jpg?v=1770330430"},{"product_id":"pr-7916-backplane-for-pr-9000-series","title":"PR 7916 Backplane for PR 9000 Series","description":"\u003cp\u003eThe PR 7916 Backplane for PR 9000 Series is a rugged, industrial interface solution. It simplifies and secures signal routing between PR 9000 \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e (I.S.) devices and standard automation systems such as \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e and DCS platforms. Ideal for high-density I\/O integration, this compact backplane supports up to 16 PR 9000 Series units and enables direct, redundant, and duplicate signal transmission. In addition, the 7916, from \u003ca rel=\"noopener\" title=\"PR electronics 7916 Backplane for PR 9000 Series\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/7900\/backplane-7916\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e I\/O and HART MUX connectivity for streamlining process automation wiring. This modular design supports analog input \/ output and digital input \/ output signals while maintaining SIL2 functional safety for installation with PR 9000 Series modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 7916 backplane is a compact and robust solution that enables a safe and easy connection of PR 9000 Series I.S. device signals into standard automation systems.\u003c\/li\u003e\n\u003cli\u003eStandard automation system cables and connectors link the backplane to I\/O cards.\u003c\/li\u003e\n\u003cli\u003eThe PR 7916 backplane is suitable for Direct, Redundant, Duplicate signaling including \u003ca rel=\"noopener\" title=\"HART Protocol\" href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\"\u003eHART\u003c\/a\u003e I\/O System connectivity (HART MUX).\u003c\/li\u003e\n\u003cli\u003ePR 9000 Series devices \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolate\u003c\/a\u003e and convert analog input \/ output (AI \/ AO) and digital input \/ output (DI \/ DO) signals coming from, or going to I.S. areas.\u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 7916 routes input \/ output signals to a system automation I\/O card. \u003c\/li\u003e\n\u003cli\u003eThe PR 9000 Series maintains a SIL2 level of functional safety, even when mounting in the backplane solution.\u003c\/li\u003e\n\u003cli\u003eFor smaller systems, the \u003ca href=\"https:\/\/www.psctexas.shop\/products\/pr-7908-backplane\" title=\"PR electronics 7908 Backplane\"\u003ePR 7908 Backplane\u003c\/a\u003e is also available and supports up to 8 modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 7916 Backplane for PR 9000 Series from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith standard I\/O cables and connectors, the PR 7916 Backplane for PR 900 Series makes it easy to connect intrinsic safe devices to non-I.S. automation I\/O cards. Thus, the 7916 reduces installation time and wiring complexity in panel designs. LED indicators and digital outputs provide clear status feedback on both PR 9000 Series devices and primary\/redundant power supplies. As a result, the PR 7916 enhances diagnostics and helps prevent unexpected downtime. The robust, compact chassis allows flexible horizontal or vertical mounting on panels or walls in safe or Zone 2\/Div 2 \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, with easy snap-on, hot-swappable module installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRobust, compact high-end design that holds (16) PR 9000 Series devices.\u003c\/li\u003e\n\u003cli\u003eDigital output indicates status of the PR 9000 Series devices and primary\/back-up \u003ca title=\"Power and Supply Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003epower supplies\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFlexible 24 VDC supply voltage and redundant power supply connection solution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOTE\u003c\/strong\u003e: PR 9000 Series modules are sold separately.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding industrial environments, the PR 7916 Backplane offers wide temperature operation  (-4 to 140˚F), flexible 24 VDC power options, and support for redundant supply configurations. Whether in service for process control, energy, or manufacturing systems, this backplane delivers reliable, organized signal distribution and powerful integration for complex automation applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible horizontal\/vertical panel or wall mounting in the Safe or Zone 2 \/ Div 2 areas.\u003c\/li\u003e\n\u003cli\u003ePR 9000 Series devices easily snap ON and OFF using piano keys, and devices can also be hot-swapped.\u003c\/li\u003e\n\u003cli\u003eTag number and ID labels easily mount and can be read using the dedicated piano key spacer.\u003c\/li\u003e\n\u003cli\u003eWide temperature operation range: -4 to 140˚F (-20 to 60˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-7916-Backplane-for-PR-9000-Series-PR-electronics-Signal-Conditioning-Module-Mounting-Device-Intrinsically-Safe-IO-Input-Output-Wiring-Process-Solutions-Corp-PCS-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7916-Backplane-for-PR-9000-Series-PR-electronics-Signal-Conditioning-Module-Mounting-Device-Intrinsically-Safe-IO-Input-Output-Wiring-Process-Solutions-Corp-PCS-Texas.jpg?v=1770389684\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"7916-ABBS8-A1A \/ ABB S800 Backplane: (16) 9106xxA or (16) 9113xA","offer_id":46498864988291,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-ABBS8-C1G \/ ABB S800 Backplane: (16) 9202xxA; 1-Channel","offer_id":46498865021059,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-ABBS8-C1H \/ ABB S800 Backplane: (16) 9202xxB; 2-Channel","offer_id":46498865053827,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-A1A \/ Honeywell Experion C300 CC-TAIX01\/11: (16) 9106xxA or (16) 9113xA","offer_id":46498865086595,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-B1A \/ Honeywell Experion C300 CC-TAOX01\/11: (16) 9107xA","offer_id":46498865119363,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-C1A \/ Honeywell Experion C300 CC-TDIL01\/11: (16) 9202xxA","offer_id":46498865152131,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-C1B \/ Honeywell Experion C300 CC-TDIL01\/11: (16) 9202xxB","offer_id":46498865184899,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-D1A \/ Honeywell Experion C300: CC-TDOB01\/11: (16) 9203xxAx","offer_id":46498865217667,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoExp-D1B \/ Honeywell Experion C300 CC-TDOB01\/11: (16) 9203xxBx","offer_id":46498865250435,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-HoRus-A1A \/ Honeywell RUSIO: (16) Universal; 1-Channel","offer_id":46498865283203,"sku":null,"price":757.0,"currency_code":"USD","in_stock":true},{"title":"7916-YoCen-C2H \/ Yokogawa Centum ADV151\/161: (16) 9202xxB","offer_id":46498865315971,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-YoCen-D2J \/ Yokogawa Centum ADV551\/561: (16) 9203xxBx","offer_id":46498865348739,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-YoPro-F2I \/ Yokogawa ProSafe SDV541: (16) 9203xxAx","offer_id":46498865381507,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-UNI-A1B \/ Universal Backplane: (16) Module; 16\/32-Channel","offer_id":46498865414275,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true},{"title":"7916-UNI-H1A \/ Universal Backplane: (16) Module; 16-Channel with HART","offer_id":46498865447043,"sku":null,"price":663.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-7916-Backplane-for-PR-9000-Series-PR-electronics-Signal-Conditioning-Digital-Input-Output-Analog-Intrinsically-Safe-Signal-Module-Process-Solutions-Corp-PSC-Texas.jpg?v=1770389702"},{"product_id":"pr-5106b-hart-ex-transparent-repeater","title":"PR 5106B HART Ex Transparent Repeater","description":"\u003cp\u003eThe PR 5106B Ex HART Transparent Repeater is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e and \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e device for industrial process automation systems. The 5106B, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports robust \u003ca title=\"HART Protocol Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication and accurate analog signal transmission. This DIN-rail mountable HART transparent repeater provides reliable galvanic isolation up to 3.75 kVAC across its multiple ports. Thus, the PR 5106B ensures safe separation of input, output, as well as supply circuits in demanding environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003ePower supply\u003c\/a\u003e and \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eIntrinsically Safe\u003c\/a\u003e (I.S.) safety barrier with 2-way HART communication for 2-wire transmitters in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eI.S. safety barrier with 2-way HART communication for supplied current transmitters in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eSignal isolator with fast response time on analog current signals from hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5106B Ex HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing microprocessor-based technology for gain and offset, the PR 5106B Ex HART Transparent Repeater efficiently processes 4-20 mA current loops with exceptional accuracy and a fast response time of less than 25 ms. Thus, the 5106B is ideal for real-time monitoring and \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eautomation control\u003c\/a\u003e applications. Its floating, galvanically isolated inputs and outputs help protect sensitive field transmitters and control systems from electrical noise and interference in addition to enhancing system stability and uptime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106B primarily processes current signals of 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater relies upon microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eThe output can connect either as an active current transmitter or as a 2-wire transmitter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for flexible installation, the PR 5106B Ex HART Transparent Repeater supports both active current transmitter connections and 2-wire transmitter modes with universal AC\/DC power compatibility. Its compact form factor allows up to 84 channels per meter of DIN rail space, thus minimizing cabinet footprint in high-density applications. Whether extending HART signal range, isolating system loops, or improving communication reliability in distributed control systems (DCS) and SCADA networks, the 5106B delivers precision, safety, and durability for industrial signal management needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106B can mount vertically or horizontally on a DIN rail. \u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without distance between neighboring units, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas.jpg?v=1769527116\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369157251,"sku":"5106B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/5106b.png?v=1769539175"},{"product_id":"pr-5107b-hart-ex-transparent-driver","title":"PR 5107B HART Ex Transparent Driver","description":"\u003cp\u003eThe 5107B, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, has been discontinued and is no longer in production. We recommend considering the \u003ca href=\"https:\/\/www.psctexas.shop\/products\/pr-9107-hart-transparent-driver\" title=\"PR electronics 9107B HART Transparent Driver\"\u003ePR 9107B\u003c\/a\u003e HART Transparent Driver.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5107B HART Ex Transparent Driver from PR electronics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSafety barrier for current signals and 2-way \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART communication\u003c\/a\u003e transmitting to I\/P converters in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eSafety barrier for 2-way HART communication and analog current signals transmitting to hazardous area.\u003c\/li\u003e\n\u003cli\u003eSignal \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolator\u003c\/a\u003e with low response time on analog current signals transmitting to hazardous area.\u003c\/li\u003e\n\u003cli\u003ePR's HART transparent driver primarily processes current signals of 4-20 mA.\u003c\/li\u003e\n\u003cli\u003ePR 5107B relies upon microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe 5107B mounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without distance between neighboring units, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369190019,"sku":"5107B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/5107b.png?v=1769528601"},{"product_id":"pr-5106-hart-transparent-repeater","title":"PR 5106 HART Transparent Repeater","description":"\u003cp\u003eThe PR 5106 HART Transparent Repeater is a high-performance \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e device for industrial process automation systems. The 5106, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports robust \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART\u003c\/a\u003e communication and accurate analog signal transmission. This DIN-rail mountable HART transparent repeater provides reliable galvanic isolation up to 3.75 kVAC across its multiple ports. Thus, the PR 5106 Series ensures safe separation of input, output, as well as supply circuits in demanding environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"PR electronics 5106A HART Transparent Repeater\" href=\"https:\/\/www.prelectronics.com\/products\/isolation\/5100\/hart-transparent-repeater-5106a\/\" target=\"_blank\"\u003ePR 5106A\u003c\/a\u003e (Safe Area version)\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003ePower supply\u003c\/a\u003e and signal isolator with 2-way HART communication for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eSignal isolator with 2-way HART communication for supplied current transmitters.\u003c\/li\u003e\n\u003cli\u003eSignal isolator with fast response time on analog current signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"PR electronics 5106B Ex HART Transparent Repeater\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/hart-transparent-repeater-5106b-u9\/\" target=\"_blank\"\u003ePR 5106B\u003c\/a\u003e (Ex \/ I.S. version)\n\u003cul\u003e\n\u003cli\u003ePower supply and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eIntrinsically Safe\u003c\/a\u003e (I.S.) safety barrier with 2-way HART communication for 2-wire transmitters in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eI.S. safety barrier with 2-way HART communication for supplied current transmitters in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eSignal isolator with fast response time on analog current signals from hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5106 HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing microprocessor-based technology for gain and offset, the PR 5106 HART Transparent Repeater efficiently processes 4-20 mA current loops with exceptional accuracy and a fast response time of less than 25 ms. Thus, the 5106 is ideal for real-time monitoring and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eautomation control\u003c\/a\u003e applications. Its floating, galvanically isolated inputs and outputs help protect sensitive field transmitters and control systems from electrical noise and interference in addition to enhancing system stability and uptime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106 Series primarily processes current signals of 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater relies upon microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eThe output can connect either as an active current transmitter or as a 2-wire transmitter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for flexible installation, the PR 5106 HART Transparent Repeater supports both active current transmitter connections and 2-wire transmitter modes with universal AC\/DC power compatibility. Its compact form factor allows up to 84 channels per meter of DIN rail space, thus minimizing cabinet footprint in high-density applications. Whether extending HART signal range, isolating system loops, or improving communication reliability in distributed control systems (DCS) and SCADA networks, the 5106 Series delivers precision, safety, and durability for industrial signal management needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106 Series can mount vertically or horizontally on a DIN rail. \u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without distance between neighboring units, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas.jpg?v=1769527116\" alt=\"PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5106ABA: 1-Channel","offer_id":46404371415171,"sku":"5106ABA","price":411.0,"currency_code":"USD","in_stock":true},{"title":"5106ABB: 2-Channel","offer_id":46404371447939,"sku":"5106ABB","price":596.0,"currency_code":"USD","in_stock":true},{"title":"5106BBA: Ex version; 1-Channel","offer_id":46404371480707,"sku":"5106BBA","price":439.0,"currency_code":"USD","in_stock":true},{"title":"5106BBB: Ex version; 2-Channel","offer_id":46404371513475,"sku":"5106BBB","price":624.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-galvanic-isolator-power-supply-signal-repeater-HART-protocol-process-solutions-corp-psc-texas.jpg?v=1769527804"},{"product_id":"pr-9106-hart-transparent-repeater","title":"PR 9106 HART Transparent Repeater","description":"\u003cp\u003eThe PR 9106 HART Transparent Repeater is a high-performance signal repeater for industrial automation and process control applications where reliable, accurate communication is critical. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device delivers robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (2.6 kVAC) to protect sensitive instrumentation from electrical interference. As a result, the 9106, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ensures consistent signal integrity, even in harsh environments. With support for active as well as passive mA inputs and outputs, the PR 9106 HART Transparent Repeater seamlessly interfaces with 2-wire SMART transmitters and current sources while enabling bi-directional \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 9106 supplies 2-wire SMART transmitters and is also suitable for use as a 2-wire SMART current source.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater supports both \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" title=\"HART Protocol\" rel=\"noopener\" target=\"_blank\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN protocols and can transfer bi-directionally.\u003c\/li\u003e\n\u003cli\u003eFor duplication\/migration purposes, outputs can send to two different DCS,  \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLC\/HMI\u003c\/a\u003e, or any monitoring system. \u003c\/li\u003e\n\u003cli\u003eModels in the 9106 Series are galvanically isolated, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/isolation\/9100\/hart-transparent-repeater-9106a\/\" title=\"PR electronics 9106A HART Transparent Repeater\" target=\"_blank\"\u003ePR 9106A\u003c\/a\u003e:\n\u003cul\u003e\n\u003cli\u003e1- or 2-Channel isolated 1:1 repeater.\u003c\/li\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-repeater-9106b\/\" title=\"PR electronics 9106B HART Ex Transparent Repeater\" target=\"_blank\"\u003ePR 9106B\u003c\/a\u003e:\n\u003cul\u003e\n\u003cli\u003e1- or 2-Channel isolated 1:1 repeater barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn safety applications (SIL loops), model 9106xxBx is suitable for use as a splitter with the following output configuration:\n\u003cul\u003e\n\u003cli\u003eWhen using 9106xxBx in a SIL2 safety function, channel 1 is the safety loop.\u003c\/li\u003e\n\u003cli\u003eChannel 2 is suitable for any non-safety device.\u003c\/li\u003e\n\u003cli\u003eFor higher safety purposes (SIL 3), 9106xxBx can function as a splitter for SIL 3 loops.\u003c\/li\u003e\n\u003cli\u003eChannel 1 and 2 then connect to the same safety PLC, where channel 2 is a redundant diagnostic channel (for more information, consult the FMEDA Report and the Safety Manual).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9106 HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing wide flexibility, the PR 9106 HART Transparent Repeater can operate as a single-channel or dual-channel repeater. Furthermore, the 9106 Series includes a splitter function to duplicate a single input to two outputs, which is ideal for feeding multiple DCS, PLC, or HMI systems without signal degradation. Its fast response time (-5 ms) and high accuracy (better than ±0.1%) ensure real-time monitoring performance. Some models of the PR 9106 feature certification for use in SIL2\/SIL3 safety loops according to \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 and is suitable for safety-critical installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe detachable displays in the \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500 series\u003c\/a\u003e and the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage on input via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9106 Series correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt;5 ms.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003e2-wire transmitter supply \u0026gt;16 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 9016 Series is compact, DIN-rail mountable, and compatible with optional detachable displays and status monitoring accessories. Furthermore, the PR 9106 is an ideal choice for enhancing HART signal reliability and expanding system integration with minimal configuration effort.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePR 9106 devices can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solution.jpg?v=1770394665\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9106A: General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo=27.5 V \/ A: 1-Channel","offer_id":46499104424067,"sku":"9106A1A","price":369.0,"currency_code":"USD","in_stock":true},{"title":"9106A: General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo=27.5 V \/ B: 2-Channel","offer_id":46499104456835,"sku":"9106A1B","price":510.0,"currency_code":"USD","in_stock":true},{"title":"9106A: General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo=25.3 V \/ A: 1-Channel","offer_id":46499104489603,"sku":"9106A2A","price":376.0,"currency_code":"USD","in_stock":true},{"title":"9106A: General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo=25.3 V \/ B: 2-Channel","offer_id":46499104522371,"sku":"9106A2B","price":524.0,"currency_code":"USD","in_stock":true},{"title":"9106Axx-U9: U9\/SIL + General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo=27.5 V \/ A: 1-Channel","offer_id":46499104555139,"sku":"9106A1A-U9","price":380.0,"currency_code":"USD","in_stock":true},{"title":"9106Axx-U9: U9\/SIL + General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo=27.5 V \/ B: 2-Channel","offer_id":46499104587907,"sku":"9106A1B-U9","price":519.0,"currency_code":"USD","in_stock":true},{"title":"9106Axx-U9: U9\/SIL + General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo=25.3 V \/ A: 1-Channel","offer_id":46499104620675,"sku":"9106A2A-U9","price":384.0,"currency_code":"USD","in_stock":true},{"title":"9106Axx-U9: U9\/SIL + General Purpose; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo=25.3 V \/ B: 2-Channel","offer_id":46499104653443,"sku":"9106A2B-U9","price":532.0,"currency_code":"USD","in_stock":true},{"title":"9106B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo=27.5 V \/ A: 1-Channel","offer_id":46499104686211,"sku":"9106B1A","price":396.0,"currency_code":"USD","in_stock":true},{"title":"9106B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo=27.5 V \/ B: 2-Channel","offer_id":46499104718979,"sku":"9106B1B","price":536.0,"currency_code":"USD","in_stock":true},{"title":"9106B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo=25.3 V \/ A: 1-Channel","offer_id":46499104751747,"sku":"9106B2A","price":402.0,"currency_code":"USD","in_stock":true},{"title":"9106B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo=25.3 V \/ B: 2-Channel","offer_id":46499104784515,"sku":"9106B2B","price":550.0,"currency_code":"USD","in_stock":true},{"title":"9106Bxx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo=27.5 V \/ A: 1-Channel","offer_id":46499104817283,"sku":"9106B1A-U9","price":406.0,"currency_code":"USD","in_stock":true},{"title":"9106Bxx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo=27.5 V \/ B: 2-Channel","offer_id":46499104850051,"sku":"9106B1B-U9","price":545.0,"currency_code":"USD","in_stock":true},{"title":"9106Bxx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo=25.3 V \/ A: 1-Channel","offer_id":46499104882819,"sku":"9106B2A-U9","price":410.0,"currency_code":"USD","in_stock":true},{"title":"9106Bxx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo=25.3 V \/ B: 2-Channel","offer_id":46499104915587,"sku":"9106B2B-U9","price":559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-HART-Transparent-Repeater-PR-electronics-9106A-Signal-Splitter-Signal-Isolation-Transmitter-Process-Solutions-Texas.jpg?v=1770396175"},{"product_id":"pr-9107-hart-transparent-driver","title":"PR 9107 HART Transparent Driver","description":"\u003cp\u003eThe PR 9107 HART Transparent Driver is a high-performance industrial signal driver for precise control and reliable communication in process automation systems. The 9107, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is suitable for both single-channel and dual-channel applications. Furthermore, the PR 9107 Series delivers galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e 1:1 current driving capability, making it ideal for powering and controlling I\/P converters, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e, and indicators in safe or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e. Its bi-directional \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e transparency ensures seamless communication with HART-enabled field devices, thus allowing real-time diagnostics, configuration, and monitoring without signal loss or interference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperation and drive control of I\/P converters, valves, and indicators.\u003c\/li\u003e\n\u003cli\u003eOperation of \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" title=\"HART Protocol\" rel=\"noopener\" target=\"_blank\"\u003eHART\u003c\/a\u003e devices is possible as the unit transmits HART communication signals bi-directionally.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series displays the process value for each channel and can also define high and low limits for detection of loop current level. If these limits are exceeded, the status relay will activate.\u003c\/li\u003e\n\u003cli\u003eDual channel versions can operate in signal splitter applications - 1 in and 2 out.\u003c\/li\u003e\n\u003cli\u003eModels in the 9107 Series are galvanically isolated, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and feature various certifications for use in hazardous areas as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/isolation\/9100\/hart-transparent-driver-9107a\/\" target=\"_blank\" title=\"PR electronics 9107A HART Transparent Driver\" rel=\"noopener\"\u003ePR 9107A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver.\u003c\/li\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-driver-9107b\/\" target=\"_blank\" title=\"PR electronics 9107B HART Ex Transparent Driver\" rel=\"noopener\"\u003ePR 9107B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9107 HART Transparent Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9107 HART Transparent Driver features fast response times (\u0026lt; 5 ms), high load drive (725 Ω at 20 mA), and robust output line fault detection via status relay. Furthermore, the 9107 Series ensures dependable performance under industrial conditions. SIL 2 certification per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\" title=\"International Electrotechnical Commission\" rel=\"noopener\"\u003eIEC\u003c\/a\u003e 61508 attests to its suitability in safety-related systems where functional reliability is critical.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 4500 detachable displays as well as the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eA tag number can be defined for each channel.\u003c\/li\u003e\n\u003cli\u003eOutput line fault detection.\u003c\/li\u003e\n\u003cli\u003eIn the 1-channel version the status relay can be used as a simple limit switch.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9107 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFor added flexibility, a detachable PR 4500 display provides local process value indication and configurable loop current limits with alarm output. Dual-channel versions support splitter functionality, delivering a single input to two outputs for expanded system integration. Compact and DIN-rail mountable, the PR 9107 HART Transparent Driver blends safety, precision, and versatility. Thus, the 9107 Series optimizes control system architecture while enhancing operational uptime and HART communication continuity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 9107 Series can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions.jpg?v=1770400499\" alt=\"PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9107A: Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel","offer_id":46499459530883,"sku":"9107AA","price":333.0,"currency_code":"USD","in_stock":true},{"title":"9107A: Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel","offer_id":46499459563651,"sku":"9107AB","price":455.0,"currency_code":"USD","in_stock":true},{"title":"9107Ax-U9: U9\/SIL + Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel","offer_id":46499459596419,"sku":"9107AA-U9","price":342.0,"currency_code":"USD","in_stock":true},{"title":"9107Ax-U9: U9\/SIL + Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel","offer_id":46499459629187,"sku":"9107AB-U9","price":465.0,"currency_code":"USD","in_stock":true},{"title":"9107B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel","offer_id":46499459661955,"sku":"9107BA","price":358.0,"currency_code":"USD","in_stock":true},{"title":"9107B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel","offer_id":46499459694723,"sku":"9107BB","price":482.0,"currency_code":"USD","in_stock":true},{"title":"9107Bx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel","offer_id":46499459727491,"sku":"9107BA-U9","price":367.0,"currency_code":"USD","in_stock":true},{"title":"9107Bx-U9: U9\/SIL + Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel","offer_id":46499459760259,"sku":"9107BB-U9","price":491.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-HART-Transparent-Driver-PR-electronics-9107A-HART-Protocol-Driver-Isoalted-Signal-Transmitter-Process-Solutions-Corp-PCS-Texas.jpg?v=1770404383"},{"product_id":"echotrek-series-ultrasonic-level-transmitter-for-liquids","title":"EchoTREK Series, Ultrasonic Level Transmitter for Liquids","description":"\u003cul\u003e \u003cli\u003e2-wire or 4-wire transmitter\u003c\/li\u003e \u003cli\u003eNon-contact level metering\u003c\/li\u003e \u003cli\u003eNarrow 5Â° beam angle\u003c\/li\u003e \u003cli\u003eExcellent signal processing\u003c\/li\u003e \u003cli\u003eTemperature compensated\u003c\/li\u003e \u003cli\u003eSecondary lightning protection\u003c\/li\u003e \u003cli\u003e32-point linearization\u003c\/li\u003e \u003cli\u003ePP, PVDF, PTFE housing and transducers\u003c\/li\u003e \u003cli\u003ePlug-in display module\u003c\/li\u003e \u003cli\u003ePlastic, aluminum, or stainless steel housing\u003c\/li\u003e \u003cli\u003eExplosion-proof variants available\u003c\/li\u003e \u003cli\u003eLevel and volume measurement and display\u003c\/li\u003e \u003cli\u003eOpen channel flow measurement\u003c\/li\u003e \u003cli\u003eFail-safe indication\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLevel measurement of most liquids and slurries\u003c\/li\u003e \u003cli\u003eFlammable liquids and corrosive chemicals\u003c\/li\u003e \u003cli\u003eAgriculture\u003c\/li\u003e \u003cli\u003eConstruction materials\u003c\/li\u003e \u003cli\u003eChemical industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003eOil industry\u003c\/li\u003e \u003cli\u003ePaper mill\u003c\/li\u003e \u003cli\u003eWater and wastewater industry\u003c\/li\u003e \u003cli\u003eVapor, fume, mixing blades, and light foam\u003c\/li\u003e \u003cli\u003eOpen channel flow metering\u003c\/li\u003e \u003cli\u003eLevel measurement in basins, wells, sumps, lift-stations\u003c\/li\u003e \u003cli\u003eLevel measurement of hydrocarbons, acids, aggressive liquids, any water based medium\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch4\u003eUltrasonic Level Sensor Technology Using Echo Detection\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The ultrasonic level metering technology is based on the principle of measuring the time required for the ultrasound pulses to cover the distance from the sensor to the level to be measured and back. The echoes bounced back from the surface of the medium to be measured reach the sensor surface after the time of flight of the ultrasonic impulse. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level, volume or flow proportional data with the help of the customizable tank dimensions or the pre-programmed flume \/ weir parameters. The intelligent QUEST+ process adaptive signal processing software system ensures that the electronics identifies and validates the liquid surface signal, giving reliable level monitoring. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch4\u003eEchoTREK for Liquids Ultrasonic Level Transmitter\u003c\/h4\u003e The EchoTREK Series can be used in multi-drop systems connected to MultiCONT process controller and display, or to a PC with the help of the UNICOMM HART USB and RS485 modem or similar. The EchoTREK Series is available with measurement ranges up to 82 feet, providing wide application possibilities. These ultrasonic level transmitters are use SenSonic range transducers with a full beam angle of 5 to 7 degrees connected to intelligent electronics featuring the QUEST+ advanced signal processing algorithm. \u003ch4\u003eHART Protocol and PC Communications\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The instruments with HART output can be connected to a PC using a UNICOMM SAK-305 HART-USB modem. All measured values of the EchoTREK ultrasonic level transmitters can be visualized and\/or the instruments can be remotely programmed via digital HART communication.Â Applicable software for PC: EView2 configuration software or NIVISION process visualization software. The level sensors with HART output can be connected to a PC via Bluetooth wireless connection using a UNICOMM HART- USB-Bluetooth modem (SAT-504). Power supply can be provided for the system with a USB power bank connected to the UNICOMM modem. \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch4\u003eUltrasonic Level Transmitters in HART Multidrop Loop\u003c\/h4\u003e The MultiCONT multichannel process controller processes and displays measurement data supplied by HART equipped transmitters connected to a Multidrop loop. The transmitters (also mixed models) can be connected and remote programming can be also performed through theMultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed.Â The visualisation of the data can be done by NIVISION process visualization software.Â With the help of MultiCONT, different useful functions can be achieved such as configuring and optimizing the measurement or displaying the special echo map of the process environment. \u003ch4\u003eEasy Process Control with EchoTREK Series Level Sensors for Liquids\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 7\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e With the help of the SAP-200 plug-in display a full-parameter programming can be accomplished, the parameters of measurement and output can be set using the alphanumeric display module. The large LCD display displays the measured values in numerical and bar graph form. The display features indication for the infrared communication (IrDA) port which provides possibility for logger readout, diagnostics and software upgrade. The MultiCONT multichannel process controller and display unit is able to visualize the Echo Map. The Echo Map feature helps to detect false reflections and aids the optimization of the measurement configuration. \u003ch4\u003eEchoTREK for Liquids Ultrasonic Level Transmitter Specifications\u003c\/h4\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e2-wire: 12â¦36 V DC 4-wire: 85â¦255 V AC, 20â¦28 V AC\/DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22â¦158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22â¦212Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e(absolute): 7.5â¦43.5 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e0.65â¦82 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4â¦20 mA, HART, relay\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1Â½\", 2\" BSP \/ NPT, flange\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eIP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eATEX, INMETRO, UKCA Ex\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eEchoTREK Ultrasonic Level Transmitter for Liquids Model Line-Up\u003c\/h5\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eEchoTREK\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eSE\/SG-300\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eST\/SB-400\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSystem\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2-wire\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e4-wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eÂ± (0.2% of measured distance +0.05% of range)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eDepending on the measured distance: \u0026lt;6.5 ft: 0.04 in, 6.5â16.5 ft: 0.075 in, 16.5â33 ft: 0.2 in, \u0026gt;33 ft: 0.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAnalog\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e4 â 20 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eRelay\u003csup\u003e(2)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e#1 SPDT, 250 V AC, 3 A AC1 #2 SPDT, 30 V DC, 1 A DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDisplay\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eSAP-200: 6-digit plug-in LCD display\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital Communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eHART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eWith plastic housing: -13Â°F...158Â°F, with metal housing: -22Â°F...158Â°F, with display: -13Â°F...158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePressure \u003cem\u003e(absolute)\u003c\/em\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e\n\u003csup\u003e(3)\u003c\/sup\u003e0.5 â 3 bar (7.5 â 43.5 psig), with stainless steel transducer: 0.9 â 1.1 bar (13 â 16 psig)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e12\u003csup\u003e(4)\u003c\/sup\u003e â 36 V DC \/ 48 â 720 mW\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e85 â 255 V AC \/ 2 VA 20 â 28 V AC\/DC \/ 3 VA \/ 3 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003eElectrical protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eIn case of DC power supply: Class III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eIn case of AC power supply: with metal housing: Class I with plastic housing: Class II\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePlastic (PBT), paint coated aluminum or stainless steel\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003ePlastic (PBT), paint coated aluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSealing\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eIn case of PP transducer: EPDM; all the other transducers: FPM (Viton)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e2x M20x1.5 cable glands + internal thread for 2x 1â2\" NPT cable protective pipe, cable outer diameter: Ã0.25 â 0.45 inch, wire cross section: maximum 1.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG15)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eTransducer: IP68, Housing: IP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eExplosion protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSee: âEx Certifiedâ table below\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eNone\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e2.85 â 5 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e\u003csup\u003e(1)\u003c\/sup\u003e under optimum conditions and stabilized transducer temperature \u003csup\u003e(2)\u003c\/sup\u003e 4-wire EchoTREK transmitters have two parallel operating relays \u003csup\u003e(3)\u003c\/sup\u003e for pressure less than 0.5 bar (14.5 psig) please send us an inquiry \u003csup\u003e(4)\u003c\/sup\u003e only partial operation is provided, reliable operation without any restrictions is guaranteed at \u0026gt;13.4 V terminal voltage\u003c\/em\u003e \u003ch4\u003eEx Certified EchoTREK Ultrasonic Level Transmitters\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEchoTREK SP-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProtection type\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIntrinsically safe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eEx marking (ATEX)\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eII 1 G Ex ia IIB T6...T4 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIntrinsically safe data\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eCi â¤ 15 nF, Li â¤ 200 Î¼H, Ui â¤ 30 V, Ii â¤ 140 mA, Pi â¤ 1 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eWith plastic housing: -4Â°F...158Â°F; with metal housing: -22Â°F...158Â°F; with display: -13Â°F...158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eWith PP transducer: -4Â°F...158Â°F; with PVDF transducer: -4Â°F...176Â°F; with PTFE transducer: -22Â°F...194Â°F with stainless steel transducer: -22Â°F...212Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2x M20x1.5 metal cable glands\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878379970691,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EchoTREK-Liquids-SGP-380-4-echotrek-liquids-nivelco-echo-trek-compact-ultrasonic-level-transmitter-level-measurement-sensor.jpg?v=1763385584"},{"product_id":"echotrek-ultrasonic-level-transmitters-for-solids","title":"EchoTREK, Ultrasonic Level Transmitters for Solids","description":"\u003cul\u003e \u003cli\u003e4-wire transmitter\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003enon-contact level metering\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003enarrow 5Ë beam angle,Â 32-point linearization\u003c\/li\u003e \u003cli\u003eexcellent signal processing and temperature compensation\u003c\/li\u003e \u003cli\u003elevel and volume measurement\u003c\/li\u003e \u003cli\u003efail-safe indication\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eNon-Contact Level Sensors Measuring an Echo\u003c\/h3\u003e The EchoTREK for solids from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is a series ofÂ \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitters for measuring level\u003c\/a\u003eÂ in tanks, sumps, and more. Its \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003eultrasonic level metering technology\u003c\/a\u003e is based on the principle of measuring the time required for the ultrasound pulses to cover the distance from the sensor to the surface of the medium and back. The echoes bounced back from the surface reach the face of the sensor after the time of flight of the ultrasonic impulse. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level, volume or mass proportional data with the help of the customizable tank shape and dimensions. The intelligent QUEST+ process adaptive signal processing software system ensures that the electronics identifies and validates the solids surface signal, giving reliable level monitoring. Coning or arching caused by the filling and emptying process can result in an adversely weak echo when the transducer is installed vertically. The joystick aiming device, an important part of the EchoTREK Series ultrasonic level transmitters offers a suitable solution to minimize most of the these unfavorable effects. The optimal tilting position can be adjusted during operation and is recommended to be checked at multiple levels during the filling and emptying process. As a general rule, the best result is obtained by the transducer aimed towards the center of the tank bottom. \u003cul\u003e \u003cli\u003esecondary lightning protection\u003c\/li\u003e \u003cli\u003ePP and aluminum housing transducers with PVC foam\u003c\/li\u003e \u003cli\u003ejoystick aiming device\u003c\/li\u003e \u003cli\u003eplug-in display module\u003c\/li\u003e \u003cli\u003epowder-coated aluminum housing\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e [embed]https:\/\/www.nivelco.com\/public\/files\/538cf9a0-673f-4809-b1b8-a44124e77398\/52_EchoTREK_2_jav0527_jav.mp4[\/embed] \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eEasy to Mount and Retrofit Ultrasonic Level Transmitters\u003c\/h3\u003e Coning or arching is a general feature of solid material storage is caused by the filling and emptying process. Optimizing the aiming by the joystick is recommended in these situations. The drawing on the right shows a special flange that provides easy and fast mounting on the silo top. In case the entire tilting range of the aiming arm is required, the diameter of the opening âDâ and the thickness of the roof âVâ is to be taken into account. \u003ch3\u003eUltrasonic Level Transmitters in HART Multidrop Loop\u003c\/h3\u003e The MultiCONT processes and displays measurement data supplied by HART equipped level transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected, and remote programming can be also performed through the MultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed. Instruments with HART output can be connected to a PC interfaced by a UNICOMM HART-USB modem. All measured values can be visualized and\/or the transmitters can be remote programmed by the PC. Applicable software: EView2 configuration software or NIVISION process visualization software. \u003ch3\u003eEchoTREK Ultrasonic Level Transmitter Specifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e85-255 V AC; 11.4-40 V DC; 11.4-28 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e2-200 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART, relay\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003ejoystick aiming device\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eEchoTREK Ultrasonic Level Transmitters Specifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEchoTREK SCD-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSystem\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4-wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy*\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eÂ± (0.2% of measured distance + 0.1% of range)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e10 mm (0.4 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAnalog\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4-20 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eRelay\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSPDT, 250 V AC \/ 3 A, AC1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eHART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 140ËF, with display: -13 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 167ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.7-1.1 bar (0.07-0.11 MPa \/ 10-16 psi g) Pabsolute and Â±0.1 bar (0.01 MPa \/ 1.45 psi g) difference between ambient and tank pressure\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eI. version: 85-255 V AC \/ 6.8 VA II. version: 11.4-40 V DC \/ 4.1 W and 11.4-28 V AC \/ 4.6 VA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eClass I\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePaint coated aluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2x M20x1.5 plastic cable glands for Ã6-Ã12 mm (0.25-0.45 in) cable, 3x terminal blocks for max. 2.5 mm2 (AWG16) wire cross section, 2x 1â2\" NPT internal threads for cable protective pipes. Ex version: See: \"Ex Certified\" table below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eExplosion protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSee: \"Ex Certified\" table below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e~15.4 lb or 22 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e *\u003cem\u003eunder optimum conditions and stabilized transducer temperature\u003c\/em\u003e \u003ch3\u003eEx Certified Level Transmitters Specification\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEchoTREK SCD-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProtection type\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eDust Ex\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eEx marking\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eII 1\/2 D Ex ma ta\/tb IIIC T85ËC...T130ËC Da\/Db\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 140ËF, with display: -13 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 167ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2x M20x1.5 cable glands with Ex ta IIIC protection type for Ã7-Ã12 mm cable, 3x terminal blocks for maximum 2.5 mm\u003csup\u003e2\u003c\/sup\u003e wire cross section, 2x 1â2\" NPT internal threads for cable protective pipes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003erelay: SPDT, 250 V AC \/ 3 A, AC1\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of EchoTREK Ultrasonic Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003emeasurement of normal and explosive dust hazardous powders and bulk solids\u003c\/li\u003e \u003cli\u003elevel measurement of free flowing solids, light powders, coarse bulk solid materials\u003c\/li\u003e \u003cli\u003elevel, volume, and weight calculation\u003c\/li\u003e \u003cli\u003elong distance measurement\u003c\/li\u003e \u003cli\u003elight dust during filling\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003epetrochemical and chemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003emining industry\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380003459,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EchoTREK-solids-SBD-34J-ultrasonic-level-transmitter-water-tank-measurement-sensor-echo.jpg?v=1763385585"},{"product_id":"easytrek-ultrasonic-level-transmitter-for-solids","title":"EasyTREK, Ultrasonic Level Transmitter for Solids","description":"\u003cul\u003e \u003cli\u003e4-wire transmitter\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003enon-contact level metering\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003enarrow 5Ë beam angle,Â 32-point linearization\u003c\/li\u003e \u003cli\u003eexcellent signal processing and temperature compensation\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/lightning-protection\/\"\u003esecondary lightning protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ePP and aluminum housing transducers with PVC foam\u003c\/li\u003e \u003cli\u003ejoystick aiming device\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003elevel and volume measurement\u003c\/li\u003e \u003cli\u003efail-safe indication\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eUltrasonic Level Sensors Measuring an Echo\u003c\/h3\u003e The EasyTREK is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e for measuring the level of solids. Its \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003eultrasonic level metering technology\u003c\/a\u003e is based on the principle of measuring the time required for the ultrasound pulses to cover the distance from the sensor to the surface of the medium and back. The echoes bounced back from the surface reach the face of the sensor after the time of flight of the ultrasonic impulse. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level, volume, or mass proportional data with the help of the customizable tank shape and dimensions. The intelligent QUEST+ process adaptive signal processing software system ensures that the electronics identifies and validates the solids surface signal, giving reliable level monitoring. Coning or arching caused by the filling and emptying process can result in an adversely weak echo when the transducer is installed vertically. The joystick aiming device, an important part of the EasyTREK Series ultrasonic level transmitters offers a suitable solution to minimize most of the these unfavorable effects. The optimal tilting position can be adjusted during operation and is recommended to be checked at multiple levels during the filling and emptying process. As a general rule, the best result is obtained by the transducer aimed towards the center of the tank bottom.   [embed]https:\/\/www.nivelco.com\/public\/files\/b28caae0-3526-4edf-877b-77b55e6e0ac3\/12_EasyTREK_S.mp4[\/embed] \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eEasy to Mount and Retrofit Ultrasonic Level Sensor\u003c\/h3\u003e Coning or arching is a general feature of solid material storage is caused by the filling and emptying process. The drawing on the right shows a special flange that provides easy and fast mounting on the silo top. In case the entire tilting range of the aiming arm is required, the diameter of the opening âDâ and the thickness of the roof âVâ is to be taken into account. \u003ch3\u003eUltrasonic Level Transmitter in HART Multidrop Loop\u003c\/h3\u003e The MultiCONT processes and displays measurement data supplied by HART equipped level transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected, and remote programming can be also performed through the MultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed. Instruments with HART output can be connected to a PC interfaced by a UNICOMM HART-USB modem. All measured values can be visualized and\/or the transmitters can be remote programmed by the PC. Applicable software: EView2 configuration software or NIVISION process visualization software. \u003ch3\u003eEasyTREK Ultrasonic Level Transmitter Specifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e11.4-40 V DC, 11.4-28 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e2-200 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART, relay\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1\" BSP and joystick aiming device\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, EAC Ex\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eEasyTREK Ultrasonic Level Transmitter Model Line-Up\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEasyTREK SCD-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSystem\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4-wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy*\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eÂ± (0.2% of measured distance + 0.1% of range)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e10 mm (0.4 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAnalog\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4-20 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eRelay\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSPST, 48 V AC \/ 5 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eHART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.7-1.1 bar (0.07-0.11 MPa [10-16 psi g]) Pabsolute and Â±0.1 bar (0.01 MPa [1.45 psi g]) difference between ambient and tank pressure\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e11.4-40 V DC \/ 4.7 W or 11.4-28 V AC \/ 5.2 VA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSame as the transducer housing material\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLiYCY type 7x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.3 in cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eExplosion protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eSee: \"Ex Certified\" table below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e~6.6-7.7 lb, or 14.3 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e *\u003cem\u003eunder optimum conditions and stabilized transducer temperature\u003c\/em\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eEx Certified Level Transmitter Model Line-Up\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEasyTREK SCD-300\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProtection type\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eDust Ex\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eEx marking\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eII 1 D Ex ma ta IIIC T85Â°C...T130 Â°C Da\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22 to 167ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLiYCY type 7x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.3 inch cable; standard cable length: 16.5 ft\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eelectronic switch: SPST, 48 V AC 50 V DC \/ 1 A\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of EasyTREK Ultrasonic Level Transmitter for Solids\u003c\/h3\u003e \u003cul\u003e \u003cli\u003emeasurement of normal and explosive dust hazardous powders and bulk solids\u003c\/li\u003e \u003cli\u003elevel measurement of free flowing solids, light powders, coarse bulk solid materials\u003c\/li\u003e \u003cli\u003elevel, volume, and weight calculation\u003c\/li\u003e \u003cli\u003elong distance measurement\u003c\/li\u003e \u003cli\u003elight dust during filling\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003epetrochemical and chemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003emining industry\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380068995,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EasyTREK_SCD-33J-4-ultrasonic-level-transmitter-water-tank-measurement-sensor-echo-light-powder.jpg?v=1763385586"},{"product_id":"nivotrack-integrated-magnetic-level-transmitter","title":"NIVOTRACK Integrated, Magnetic Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire integrated transmitter with HART communication\u003c\/li\u003e \u003cli\u003e1 mm resolution\u003c\/li\u003e \u003cli\u003edistance, interface, level measurement\u003c\/li\u003e \u003cli\u003enormal and mini rigid guide tube versions\u003c\/li\u003e \u003cli\u003estainless steel or titanium floats\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eNIVOTRACK Integrated Series Magnetic Level Transmitters\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e NIVOTRACK from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is a magnetic \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e for high accuracy measurements of clean fluids. Its high precision renders the NIVOTRACK suitable for custody transfer measurements. Integrating the transmitter into a \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/\"\u003eprocess control system\u003c\/a\u003e is easy thanks to the intelligent signal processing and communication software as well as the wide of range of accessories offered. \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e A float containing a magnetic disc moves along a guide tube with the specific magnetostrictive wire in it. A pulse generated by the electronics travels along the magnetostrictive wire. At the point the pulse reaches the floatâs magnetic field, a torsion develops. Reflected from the torsion point, the pulse creates an acoustic wave that travels back along the wire. The 4-20 mA output of the transmitter is proportional to the elapsed time between the excitation and detection. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ca href=\"https:\/\/www.nivelco.com\/public\/files\/c3d19471-3114-4a67-8494-a2a6136bc663\/42_NIVOTRACK.mp4\"\u003e\u003cimg class=\"size-medium alignleft\" src=\"https:\/\/www.nivelco.com\/public\/files\/c3d19471-3114-4a67-8494-a2a6136bc663\/42_NIVOTRACK.mp4\" alt=\"magnetic-level-transmitter-nivotrack-nivelco\" width=\"1920\" height=\"1080\"\u003e\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12.5-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003emax. 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1-11.5 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1\", 2\" BSP \/ NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOTRACK Integrated Series Magnetic Level Transmitters Model Line-Up\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version â Standard\u003c\/strong\u003e\u003cem\u003e (MI configurations)\u003c\/em\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version â Mini\u003c\/strong\u003e\u003cem\u003e (MY configurations)\u003c\/em\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMeasured Process Value\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eliquid level, distance\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eNominal Length (L)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3-3.5 m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3-1.5 m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMaterial of the Tube\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1.4571 (316Ti) stainless steel\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Medium Pressure(1)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.5 MPa (25 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.6 MPa (16 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMedium Temperature(1)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eStandard Float Diameter \/ Material(1)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã54 x 60 mm cylindrical \/ 1.4404 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã28 x 29 mm \/ 1.4404 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMedium Density\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eÃ54 mm float min. 0.8 g\/cm\u003csup\u003e3\u003c\/sup\u003e; Ã54 mm titanium float min. 0.55 g\/cm\u003csup\u003e3\u003c\/sup\u003e Ã95 mm float min. 0.55 g\/cm\u003csup\u003e3\u003c\/sup\u003e Ã124 mm or Ã95 mm titanium float min. 0.4 g\/cm\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaterial of Wetted Parts\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Stainless steel: 1.4571 (316Ti) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"1\" rowspan=\"2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAnalog\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 4-20 mA (limit values: 3.9-20.5 mA) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eDigital Communication\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eHART (minimum loop resistance: 250 Î©)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eError Indication\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Output signal = 22 mA or 3.8 mA \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eOutput Load\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eRt = (Ut - 12.5 V) \/ 0.02 A, Ut = power supply voltage\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 12.5â36 V DC \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eElectrical Protection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eClass III\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rated\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMass\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.9 kg + measuring probe: 0.6 kg\/m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e2.9 kg + measuring probe: 0.3 kg\/m\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/09\/nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini.jpg\"\u003e\u003cimg class=\"alignnone wp-image-17065 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/09\/nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini.jpg\" alt=\"nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini\" width=\"1800\" height=\"661\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eCommon Uses of NIVOTRACK Integrated Magnetic Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003elevel measurement of liquids, with minimum 25 lb \/ ft\u003csup\u003e3\u003c\/sup\u003e density\u003c\/li\u003e \u003cli\u003elevel monitoring of tanks\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemicals, solvents, hydrocarbons\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380101763,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOTRACK-MIA-500-nivelco-integrated-level-transmitter-measuring-sensor-water-liquids-measurement.jpg?v=1763385587"},{"product_id":"nivotrak-compact-series-magnetostrictive-level-transmitter","title":"NIVOTRAK Compact Series, Magnetostrictive Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire compact transmitter\u003c\/li\u003e \u003cli\u003e0.004 inch or 0.04 inch resolution\u003c\/li\u003e \u003cli\u003ewetted parts: stainless steel or plastic\u003c\/li\u003e \u003cli\u003eplug-in graphic display module\u003c\/li\u003e \u003cli\u003e99-point linearization\u003c\/li\u003e \u003cli\u003edistance, level, volume, interface measurement\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ecustody transfer measurement (OIML R 85)\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e [embed]https:\/\/www.nivelco.com\/public\/files\/a7fef03e-548d-4818-be66-1bb05d2d73b0\/08_NIVOTRACK.mp4[\/embed] \u003ch3\u003eMagnetostrictive Level Transmitter Operating Principles\u003c\/h3\u003e This \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e uses a float containing a magnetic disc moves along a guide tube with the specific magnetostrictive wire in it. A pulse generated by the electronics travels along the magnetostrictive wire. At the point the pulse reaches the floatâs magnetic field, a torsion develops. Reflected from the torsion point, the pulse creates an acoustic wave that travels back along the wire. The 4-20 mA output of this magnetostrictive level transmitter from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is proportional to the elapsed time between the excitation and detection. \u003ch3\u003eHART Protocol Connected\u003c\/h3\u003e The instrument with HART output can be connected to a PC using an UNICOMM HART USB modem. Max. 15 normal (non Ex) instruments can be connected to a HART line. Measured values can be visualized and\/or the instruments can be programmed via digital HART communication. EView2 configuration software or NIVISION process visualization software. MultiCONT can handle a maximum of 15 HART capable transmitters (4 Ex-version transmitters). The digital (HART) information is processed, displayed, and if needed, it can be transmitted via RS485 communication line to a PC. Remote programming of the transmitters is also possible. Visualization on PC can be accomplished with NIVISION process visualization software. \u003ch3\u003eNIVOTRACK Compact Series Magnetostrictive Level Transmitter Specifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12.5-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003emax. 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e0-50 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP67 (IP68)\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, IEC Ex, OIML R 85\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOTRACK Compact Series Magnetostrictive Level Transmitter Specifications\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eFlexible Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003ePlastic Coated Rigid Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMini Version with Rigid Probe\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMeasured Process Value\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e liquid level, distance, volume \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eNominal Length (L)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.5-14.5 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 6.5-50 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.5-10 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1.5-4.5 ft\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaterial of the Tube\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4571 (316 Ti) stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e PFA coated stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4571 stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMax. Medium Pressure (1)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.5 MPa (25 bar g \/ 363 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.6 MPa (16 bar g \/ 232 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3 MPa (3 bar g \/ 43.5 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1 MPa (10 bar g \/ 145 psi g)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e -40 to 194ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eStandard Float Diameter \/ Material (2)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 x 2.35â cylindrical \/ 1.4404 (316L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 4â ball \/ 1.4435 (316L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 3 x 3.45â cylindrical \/ PVDF \/ PP \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1 x 1.15â cylindrical 1.4404 (316L)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMaterial of Wetted Parts\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e stainless steel: 1.4571, 1.4404 (316 Ti, 316 L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e PFA, PVDF, PP \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003estainless steel: 1.4571, 1.4404\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"1\" rowspan=\"3\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAnalog\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e4-20 mA (limit values: 3.9-20.5 mA)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDigital\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e4-20 mA + HART\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eSAP-300 graphic display\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eDamping Time\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eAdjustable 0 to 99 s\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eError Indication\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 22 mA or 3.8 mA or holding \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eOutput Load\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eRt = (Ut-12.5V) \/ 0.02 A, Ut = power supply voltage\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 12.5-36 V DC \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eElectrical Protection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eClass III\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP 67 rated\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eElectric Connection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2x M20x1.5 plastic cable glands for 0.25-0.5 inch cable + 2x NPT 1â2 â internal thread for cable protective pipe terminal block for 0.5-1.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG 20 - AWG 15) wire cross section \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eHousing\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003ePaint coated aluminum or plastic (PBT)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.3.75 lb + m. probe: 0.4 lb\/ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 6.4 lb + m. probe: 0.2 lb\/ft + counter weight 7.7 lb \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 3.75 lb + m. probe: 0.45 lb\/ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e3.75 lb + m. probe: 0.4 lb\/ft\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of Magnetostrictive Level Transmitters\u003c\/h3\u003e \u003cul\u003e \u003cli\u003elevel measurement of normal and flammable liquids with minimum 0.4 specific gravity\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemicals, solvents, and hydrocarbons\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eplastic coated version for chemicals\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy industry, ATG (Automatic Tanking Gauge)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ecustody transfer measurement\u003c\/li\u003e \u003cli\u003efuels and gasoline products\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003ePharmaceutical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003eFood industry, alcohols, and beverages\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003einstallation in bypass tubes feasible\u003c\/li\u003e \u003cli\u003esupplementary level transmitter for \u003ca href=\"https:\/\/psctexas.com\/product\/nivoflip-bypass-liquid-level-indicator\/\"\u003eNIVOFLIP magnetic flip indicator\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380134531,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Nivelco_NIVOTRACK-MCA-500-nivotrack-nivelco-magnetostrictive-level-transmitter-measuring-level-sensor.png?v=1763385588"},{"product_id":"pilotrek-integrated-microwave-level-transmitter","title":"PiloTREK Integrated, Microwave Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire integrated transmitter for non-contact level metering\u003c\/li\u003e \u003cli\u003e25 GHz (K-band) measuring signal\u003c\/li\u003e \u003cli\u003eAccuracy up to Â±0.12 inch, 99-point linearization\u003c\/li\u003e \u003cli\u003eMeasuring range up to 75 feet\u003c\/li\u003e \u003cli\u003ePlastic housing\u003c\/li\u003e \u003cli\u003eHorn, planar, or parabolic antenna\u003c\/li\u003e \u003cli\u003eStainless steel or plastic encapsulated sensor\u003c\/li\u003e \u003cli\u003eExplosion-proof and IP68 variants available\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLevel measurement of liquids, emulsions, slurries, and other chemicals\u003c\/li\u003e \u003cli\u003eLevel measurement through plastic tank wall\u003c\/li\u003e \u003cli\u003eAgriculture\u003c\/li\u003e \u003cli\u003eConstruction materials\u003c\/li\u003e \u003cli\u003eChemical industry, for mid to large size vessels or chemical tanks\u003c\/li\u003e \u003cli\u003ePharmaceutical and chemical industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003ePower plants\u003c\/li\u003e \u003cli\u003eOil and petrochemical industry\u003c\/li\u003e \u003cli\u003eWater and wastewater industry\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eLinearly Polarized Microwave Impulses\u003c\/h4\u003e The PiloTREK Integrated Series pulse burst radar level transmitters emit linearly polarized microwave impulses. The polarization plane of the emitted impulses can be rotated fully in some PiloTREK models. The rotation of the polarization plane can minimize unwanted false reflections from disturbing objects or from the tank wall. The orientation of the polarization plane coincides with the line drawn between the cable glands. \u003ch4\u003ePulse Radar Level Transmitter Operations\u003c\/h4\u003e The operation of the non-contact microwave level transmitters is based on the measurement of the time of flight of the microwave burst. The propagation speed of microwave impulses is practically the same in air, gases and in vacuum, independently from the process temperature and pressure, so the measured distance is not affected by the physical parameters of medium to be measured. The level transmitter induces microwave impulses a few nanosecond long in the antenna and a part of the energy of the emitted signals is bounced (reflected) back from the measurement surface depending on the measured media. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level or volume proportional data. The measurability of the level of a specific medium is depending on the signal strength of the reflected microwave impulses. The signal strength of the reflected impulses is considerably depending on the distance to be measured, the relative dielectric constant of the measured medium and the turbulence of the surface. The relative dielectric constant (Îµr) of the medium should be more than 1.4 in case of parabolic design, or it should be more than 1.9 with horn antenna types. \u003ch4\u003eProgramming with Echo Map\u003c\/h4\u003e With the help of the SAP-300 plug-in display, a simplified full-parameter programming can be accomplished. The parameters of measurement and output can be set using the text-based menu system.Â The large LCD dot-matrix display displays the measured values in numerical and bar graph form. The Echo Map feature helps to detect false reflections and aids the optimization of the measurement configuration. The background mapping feature provides excellent solution to ignore unwanted false reflections coming from (not-moving) disturbing objects. For this purpose the instrument needs to map the totally empty tank to create a âbackground imageâ. Then the measurement evaluation software of PiloTREK Integrated Series will automatically recognize and ignore the false reflections coming from the disturbing objects inside the tank. \u003ch4\u003ePiloTREK Integrated Series Microwave \/ Radar Level Transmitter\u003c\/h4\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e20â¦36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ4â¦+140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22â¦+356Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ14.5â¦362.6 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4â¦20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1Â½\", 2\" or flanges or sanitary\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eIP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eATEX, IEC Ex, INMETRO\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4 title=\"Page 5\"\u003ePiloTREK Microwave Level Transmitter Model Line-Up\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003ePiloTREK Series\u003c\/th\u003e \u003cth style=\"text-align: center;\" colspan=\"3\"\u003eMicrowave Level Transmitter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePiloTREK Integrated\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasured values\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLevel, Distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCalculated values\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eVolume, Mass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eFrequency of the measurement signal\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e~25 GHz (K-band)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.6 â 75 ft \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eLinearity error\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e\u0026lt;1.65 ft: Â±1 in; 1.65 â 3.3 ft: Â±0.6 in; 3.3 â 5 ft: Â±0.4 in; 5 â 26.25 ft: Â±0.12 in; \u0026gt;26.25 ft: Â±0.04% of the measured distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal beam angle\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e11Â° \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal Îµr of the medium\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e1.9 \u003cem\u003e(depending on the measuring range)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e1 mm (0.04 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eTemperature error (as per EN 61298-3)\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.05% FSK \/ 50 Â°F (-4Â°F...140Â°F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e20 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4 â 20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring frequency\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e10 â 60 sec as per the application settings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna diameter\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e38 mm (11â2\"), 48 mm (2\"), 75 mm (3\"), 148 mm (6\")\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna material\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eHorn, Parabolic: 1.4571 (316Ti) stainless steel; enclosure: PP, PTFE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22Â°F...212Â°F, (up to 248 Â°F for maximum 2 minutes) with PP antenna enclosure: maximum: 176Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMaximal process pressure\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e25 bar (363 psig) at 248Â°F; with plastic antenna enclosure: 3 bar (44 psig) at 77 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eThreaded, Flanged or Sanitary connections\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIP68\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLiYCY type. 2x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.25 inch cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical protection\u003c\/th\u003e \u003ctd class=\"\" style=\"text-align: center;\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing material\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePlastic (PP)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSealing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eViton, EPDM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCommunication certifications\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eR\u0026amp;TTE, FCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2.2 â 3.5 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e*Under reference conditions of reflection and stabilized temperature\u003c\/em\u003e \u003ch4\u003eEx Certified PiloTREK Integrated Series Microwave Level Transmitters\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003ePlastic housing\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003eEx marking\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eIEC Ex\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia IIB T6 ... T5 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eATEX\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx II 1G Ex ia IIB T6 ... T5 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eIntrinsically safe data\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLi: 200 Î¼H, Ci: 30 nF, Ui: 30 V, Ii: 140 mA, Pi: 1 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia: 20 V â 30 V DC, Ex d[ia]: 24 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIn case of WPM type: LiYCY type. 2x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.25 inch cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878381215875,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PiloTREK-integrated-_WPM-183-4-nivelco-microwave-pulse-radar-level-transmitters-measuring-sensors-slurry-emulsion-liquids.jpg?v=1763385610"},{"product_id":"pilotrek-w-200-non-contact-radar-level-transmitter","title":"PiloTREK W-200, Non-Contact Radar Level Transmitter","description":"\u003cul\u003e\n\u003cli\u003e1\", 1.5\" encapsulated horn antenna\u003c\/li\u003e\n\u003cli\u003eintegrated design with \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP68 protection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003euser-friendly threshold management\u003c\/li\u003e\n\u003cli\u003eEx variant coming soon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNon-contact Radar Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe reflection of the millimeter-waves is highly dependent on the dielectric constant of the medium. Therefore, the measured medium's dielectric constant (ε\u003csmall\u003er\u003c\/small\u003e) must be over 1.9 for millimeter-wave level measurement. The measurement principle of a level transmitter with a millimeter-waves signal is based on measuring the reflection’s time of flight. The speed of propagation of millimeter-waves signals in the air, gases, and vacuum is almost constant regardless of temperature and medium pressure. So the measured distance does not depend on the physical parameters of the intermediate medium. The PiloTREK W–200 level transmitter is a continuous-wave frequency modulated radar (FMCW) operating at 80 GHz (W-band).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHigh Accuracy Microwave Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe most obvious advantages of 80 GHz radars over lower frequency (5-12 \u0026amp; 25 GHz) radars offer a smaller antenna size, better focus, and smaller beam angle. A portion of the millimeter-wave continuous wave energy radiated by the level transmitter antenna is reflected from the measured surface, depending on the material to be measured. The distance of the reflecting surface is calculated with high accuracy by the electronics from the frequency shift of the reflected signal and converted into a distance, level, or volume signal by the electronics.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDielectric Constant Values (ε\u003csmall\u003er\u003c\/small\u003e)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eButane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5-10\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCooking O\u003c\/strong\u003e\u003cstrong\u003eil\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLPG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6-1.9\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimestone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1-9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKerosene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8-2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAcetone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrude Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiesel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMethanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasoline\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGlycol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsphalt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrobenzene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClinker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4-3.6\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSulfuric Acid\u003c\/strong\u003e \u003cem\u003e(T=68˚F [20˚C])\u003c\/em\u003e\n\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eHART Enabled Multidrop Loop\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/pilotrek-w-200-nivelco-noncontact-radar-level-measurement-hart-communication-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana-300x145.jpg\" alt=\"pilotrek-w-200-nivelco-noncontact-radar-level-measurement-hart-communication-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003eMultiCONT multichannel process controllers process and display measurement data supplied by NIVELCO HART equipped transmitters in a Multidrop loop. Connected transmitters can be programmed through MultiCONT, and it can also perform data gathering duties. Processed data may be sent to a computer via RS485 and displayed in NIVISON. MultiCONT provides the means to optimize and configure measurements and display the echo maps of the particular installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBluetooth Enabled Level Transmitter\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/nivelco-tank-bluetooth-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-instrumentation-300x124.jpg\" alt=\"nivelco-tank-bluetooth-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-instrumentation\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003eInstruments with HART connectivity can be linked to a PC via \u003ca rel=\"noopener\" href=\"https:\/\/www.bluetooth.com\" target=\"_blank\"\u003eBluetooth\u003c\/a\u003e using a UNICOMM HART–USB-Bluetooth modem (SAT–504). The USB power bank connected to the UNICOMM modem can power the entire setup.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e12 to 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–40 to 176 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–40 to 176 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–14.5 to 43.5 psi (–0.1 to 0.3 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e0 to 98.5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e4 to 20 mA + HART, optional SPDT output, service interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e1\", 1.5\" BSP \/ NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eATEX (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003ePiloTREK W-200 Level Transmitter Model Line Up\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/nivelco-tank-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-industrial-instrumentation.jpg\" alt=\"nivelco-tank-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-industrial-instrumentation\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eCommon Level Measurement Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003elevel measurement of liquids, emulsions, and other chemicals up to 98.5 ft\u003c\/li\u003e\n\u003cli\u003emedium and large storage tanks or chemical tanks\u003c\/li\u003e\n\u003cli\u003emeasurement through a plastic tank wall\u003c\/li\u003e\n\u003cli\u003ematerial prone to vapor formation\u003c\/li\u003e\n\u003cli\u003eliquids with a gas cushion\u003c\/li\u003e\n\u003cli\u003esuitable for use in a vacuum\u003c\/li\u003e\n\u003cli\u003eopen channel flow measurement\u003c\/li\u003e\n\u003cli\u003erevenue water and wastewater industry\u003c\/li\u003e\n\u003cli\u003eenergy industry, oil and gas production\u003c\/li\u003e\n\u003cli\u003efood and beverage industry\u003c\/li\u003e\n\u003cli\u003epharmaceutical industry\u003c\/li\u003e\n\u003cli\u003echemical \/ petrochemical industry\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/marine-certified\/\"\u003emarine applications\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878392586371,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/pilotrek-w-200-nivelco-noncontact-radar-level-measurement-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana.png?v=1763385946"},{"product_id":"nivocap-capacitive-level-transmitter","title":"NIVOCAP Capacitive Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire compact transmitter\u003c\/li\u003e \u003cli\u003eplug-in display module\u003c\/li\u003e \u003cli\u003e32-point linearization\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003cli\u003e32-point linearization table\u003c\/li\u003e \u003cli\u003eindirect assignment of 0% and 100%\u003c\/li\u003e \u003cli\u003ehigh sensitivity\u003c\/li\u003e \u003c\/ul\u003e The NIVOCAP is a capacitive \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e that uses the plates of the capacitor as a probe and the reference probe (wall of the tank) for level measurement. The dielectric constant of the air is Îµ\u003csmall\u003er\u003c\/small\u003e=1. The basic capacity of the probe mounted in empty tank is C0, which depends on the relative dielectric constant of the air and the mounting position. During filling the capacitance between probe and reference will increase proportionally with the level and the (Îµ\u003csmall\u003er\u003c\/small\u003e) relative dielectric constant of the medium. The condition of an accurate level metering is that the change of capacity has to be proportional to the change in level. To comply with the above the probe and the referential probe have to be parallel, because capacity depends on the distance between the two plates. Best suited for the most accurate level measurement is the so called coaxial arrangement. \u003cimg class=\"alignnone size-medium\" src=\"https:\/\/www.nivelco.com\/public\/files\/3ff6b055-3600-4983-a831-5c6278f3b95e\/05_NIVOCAP.mp4\" alt=\"NIVOCAP-Capacitive-Level-Transmitter-Nivelco-process-solutions\" width=\"1920\" height=\"1080\"\u003e \u003ch3\u003eEasy Set Up and Configuration\u003c\/h3\u003e Setting up the NIVOCAP is easy. Using a simple technique the unit is to be âtaughtâ the minimal (close to minimal) and maximal (close to maximal) levels. If fully filling and draining is inconvenient or not feasible, the teaching is possible at any odd levels with the help of indirect assignment feature. \u003cul\u003e \u003cli\u003e4-20 mA + HART output\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP67 ingress protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erod (7.8 inches to 9.8 ft) or cable (39 inches to 65 ft) probe\u003c\/li\u003e \u003cli\u003eplastic, aluminum, or stainless steel housing\u003c\/li\u003e \u003cli\u003epartially or fully insulated probe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eRod or Cable Probe Options\u003c\/h5\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-online-procurement-PCS-Texas-arrangements.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21635 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-online-procurement-PCS-Texas-arrangements.jpg\" alt=\"NIVOCAP-Nivelco-Capacitive-Level-Transmitter-online-procurement-PCS-Texas-arrangements\" width=\"1000\" height=\"546\"\u003e\u003c\/a\u003e \u003ch5\u003eProbe Selection\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-rod-cable-probe-selection.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21637 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-rod-cable-probe-selection.jpg\" alt=\"NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-rod-cable-probe-selection\" width=\"500\" height=\"484\"\u003e\u003c\/a\u003e\n\u003c\/h5\u003e \u003ch3\u003eEasy to Program Capacitive Level Transmitter\u003c\/h3\u003e Basic functions can be configured by the programming buttons. With the help of the SAP-202 plug-in display a simplified programming can be accomplished which covers full parameter programming. \u003ch3\u003eHART Compatible Level Measurement\u003c\/h3\u003e The MultiCONT processes and displays measurement data supplied by \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e HART equipped transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected and remote programming can be also performed through the MultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed. \u003ch3\u003eControl From Your PC\u003c\/h3\u003e Instruments with HART output can be connected to a PC interfaced by a UNICOMM HART-USB modem. A HART multidrop loop can consist of a maximum of 15 \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003etransmitters\u003c\/a\u003e. All measured values can be visualized and\/or remote programmed by the PC. Applicable software: EView2 configuration software or NIVISION process visualization software. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e12-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ13 to 158 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ22 to 392 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003emax. 580 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e1\", 1.5\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP67\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOCAPÂ Capacitive Level Transmitter Model Line Up\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-model-line-up.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21636 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-model-line-up.jpg\" alt=\"NIVOCAP-Nivelco-Capacitive-Level-Transmitter-Process-Solutions-Corp-model-line-up\" width=\"1000\" height=\"539\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of NIVOCAP Capacitive Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003edistance, level, and volume measurement of liquids, powders, granules, with Îµ\u003csmall\u003er\u003c\/small\u003e \u0026gt; 1.5 relative dielectric constant\u003c\/li\u003e \u003cli\u003eideal for chemicals with dense gas layers above the surface\u003c\/li\u003e \u003cli\u003ehigh pressure, high temperature, or vacuum mediums\u003c\/li\u003e \u003cli\u003eviscous or corrosive mediums\u003c\/li\u003e \u003cli\u003evolume and level measurement\u003c\/li\u003e \u003cli\u003elevel measurement of conductive and non-conductive materials\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement of liquids\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878393143427,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOCAP-Nivelco-Shop-Online-Best-Capacitive-Level-Transmitter-Process-Solutions-PSC-Texas.png?v=1763385948"},{"product_id":"nivopress-d-2-wire-level-transmitter","title":"NIVOPRESS D, 2-Wire Level Transmitter","description":"\u003cul\u003e \u003cli\u003e0.25% accuracy\u003c\/li\u003e \u003cli\u003egauge or absolute pressure transmitter\u003c\/li\u003e \u003cli\u003ewide pressure range selection\u003c\/li\u003e \u003cli\u003epiezoresistive sensor with stainless steel flush diaphragm\u003c\/li\u003e \u003cli\u003etemperature compensation with high temperature range\u003c\/li\u003e \u003cli\u003eHART communication\u003c\/li\u003e \u003cli\u003eplug-in display module\u003c\/li\u003e \u003cli\u003ewide variety of process connections\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 Ingress Protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area ratings available\u003c\/a\u003e: explosion proof and \u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e (Ex ia G)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eNIVOPRESS D 2-Wire Level Transmitter\u003c\/h3\u003e Due to their design, the NIVOPRESS D front diaphragm level transmitters are particularly suitable for \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measuring\u003c\/a\u003e tasks by measuring pressure at the bottom of the tank. The same design makes it an excellent instrument for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood applications such as milk or pastes\u003c\/a\u003e. The smooth membrane surface and the maximum permissible medium temperature of 257ËF (125ËC) ensure hygienic cleaning in technologies that require regular cleaning and eliminate the risk of clogging. The device can be used for all level measurement tasks with atmospheric pressure above the liquid column.   [embed]https:\/\/www.nivelco.com\/public\/files\/c51b8d7e-9b41-4baf-8e37-f3a4d8e812fe\/06_NIVOPRESS%20D.mp4[\/embed] \u003ch3\u003eLevel Measurement Using a HART Multidrop Loop\u003c\/h3\u003e MultiCONT Multichannel Process Controller can handle up to 15 normal HART or up to 4 Ex-proof HART capable \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO transmitters\u003c\/a\u003e. Digital (HART) information is processed, displayed, and if necessary, transmitted via RS485 to a computer. Remote programming of the transmitters is also possible. Processes can be visualized on computers by using NIVISION. \u003ch3\u003e2-Wire Level Transmitter with Easy Programming Via PC\u003c\/h3\u003e HART output devices and a UNICOMM SAKâ305 HART-USB modems can be connected to a PC via a wire, while using a UNICOMM SATâ504 HARTâUSB \/ Bluetooth modem, the transmitters can be connected via Bluetooth. All data measured by the NIVOPRESS D can be displayed on the PC, and the devices can be reprogrammed if required. For a HART modem, a maximum of 15 standard transmitters can be connected. In addition, the EView2 configuration or NIVISION process visualization software can also be used. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e10-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ40 to 158 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ13 to 257 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003emax. 5800 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e1\", 1.5\", flanges, hygienic fittings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOPRESS 2-Wire Level Transmitter Model Line Up\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-d-nivelco-tank-pressure-best-level-gauge-sensor-industrial-instrumentation-distributor-psc-texas-model-line-up.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21659 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-d-nivelco-tank-pressure-best-level-gauge-sensor-industrial-instrumentation-distributor-psc-texas-model-line-up.jpg\" alt=\"NIVOPRESS-d-nivelco-tank-pressure-best-level-gauge-sensor-industrial-instrumentation-distributor-psc-texas-model-line-up\" width=\"1000\" height=\"736\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of NIVOPRESS 2-Wire Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eliquids and weights in tanks and vessels\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemicals with dense vapor or gas layers above the surface\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ehighly viscous or corrosive substances\u003c\/li\u003e \u003cli\u003efoaming liquids and masses in tanks and vessels\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878394192003,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOPRESS-d-nivelco-tank-pressure-level-gauge-sensor-online-distributor-industrial-instrumentation-process-solutions-corp.png?v=1763385949"},{"product_id":"nivopress-n-hydrostatic-level-transmitter","title":"NIVOPRESS N, Hydrostatic Level Transmitter","description":"\u003cul\u003e \u003cli\u003emeasuring range up to 656 ft (200 m)\u003c\/li\u003e \u003cli\u003estailess steel or fully plastic body\u003c\/li\u003e \u003cli\u003eventing tube in cable\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eremote programmable\u003c\/li\u003e \u003cli\u003eÃ22 \/ 24 mm (Ã0.85 \/ 1 inch) tube\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e [embed]https:\/\/www.nivelco.com\/public\/files\/803db18b-ee74-4bf8-8051-1cc788a97cde\/07_NIVOPRESS%20N.mp4[\/embed] \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eNIVOPRESS N Hydrostatic Level Transmitter\u003c\/h3\u003e The NIVOPRESS N hydrostatic borehole level transmitters are designed by \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e to \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003emeasure the level\u003c\/a\u003e of clean or contaminated liquids. The \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/submersible-pressure-transducers\/\"\u003epressure sensor at the bottom of the probe measures the hydrostatic pressure (Phydr)\u003c\/a\u003eÂ of the liquid column above it and compares with the atmospheric pressure (Patm). The atmospheric pressure is led to the hydrostatic level transmitter through a breathing capillary. This capillary is equipped with a moisture filter that prevents moisture from reaching the electronics, which would decrease the accuracy of the measurement. This enables the atmospheric pressure to be subtracted from the measured pressure to get the hydrostatic pressure which is proportional to the height of the liquid column (h). The electronics convert the \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e signal into an output signal. If temperature measurement of the liquid is needed beside the level measurement, a combined level + temperature \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/submersible-level-transmitters\"\u003esubmersible level transmitter\u003c\/a\u003e should be used. \u003ch3\u003eScrew-in or Submersible Level Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant.jpg\"\u003e\u003cimg class=\"alignright wp-image-21664 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant.jpg\" alt=\"NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e The installation and wiring of the transmitter is helped by the wide variety of accessories. A sewage adapter working on the principle of the diving bell can be snapped (NP) or can be screwed (NZ) into the place of the protecting cap to avoid the direct contact between the sensor and the measured contaminated liquid. Â An extra mechanical protection is built in the NZ type sewage adapters in the form of a mechanical filter. The N-500 are \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazLoc rated models\u003c\/a\u003e that can be used in hazardous environments. The NZ screw-in model transmitters are recommended for applications where there is a risk of flooding. The NB \/ NG plastic housing models are designed for applications where an aggressive medium (e.g. saline solutions or seawater) could cause galvanic corrosion of the stainless steel body. \u003cul\u003e \u003cli\u003eHART communication\u003c\/li\u003e \u003cli\u003e2-wire or 3-wire versions\u003c\/li\u003e \u003cli\u003etwo 4-20 mA output (level + temperature)\u003c\/li\u003e \u003cli\u003ebuilt-in Pt100 temperature sensor\u003c\/li\u003e \u003cli\u003eover-voltage and inverse polarity protection\u003c\/li\u003e \u003cli\u003eHazLoc ratings available: explosion proof, ATEX (Ex ia)\u003c\/li\u003e \u003cli\u003esubmersible or screw-in types\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eNIVOPRESS N Hydrostatic Level Transmitter Model Line Up\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21662 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up.jpg\" alt=\"NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up\" width=\"1000\" height=\"811\"\u003e\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e12-30 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e0 to 1,150 ft\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e4-20 mA + HART, 0-10 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, UKCA Ex\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of NIVOPRESS N Submersible Hydrostatic Level Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21672 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical.jpg\" alt=\"NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical\" width=\"1000\" height=\"576\"\u003e\u003c\/a\u003e \u003cul\u003e \u003cli\u003elevel metering of small diameter pipes, sewage water, saline solutions, sea water, potable water tanks, etc.\u003c\/li\u003e \u003cli\u003eborehole transmitter for the \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater industry\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ecan be certified for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003epotable water, revenue water\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product-category\/temperature\/\"\u003etemperature measurement\u003c\/a\u003e of \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003edrinking water wells, tanks, pools\u003c\/a\u003e, etc.\u003c\/li\u003e \u003cli\u003esubmersible pump control\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/submersible-level-transmitters\"\u003escrew-in submersible model\u003c\/a\u003e with \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 protection\u003c\/a\u003e for applications with risk of flooding\u003c\/li\u003e \u003cli\u003eclean or slightly contaminated liquids\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003esewage and wastewater\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003edraw-down protection\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003esewage lift station control\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878394617987,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOPRESS-N-submersible-hydrostatic-level-transmitter-pressure-sensor-lift-station-sensor-psc-texas-oklahoma-louisiana.png?v=1763385952"},{"product_id":"easytrek-pro-non-contact-level-transmitter-for-liquids","title":"EasyTREK Pro Non-Contact Level Transmitter for Liquids","description":"\u003cdiv class=\"nv-product nv-html-bind ng-binding\"\u003e \u003cul\u003e \u003cli\u003equick start mode\u003c\/li\u003e \u003cli\u003ecan be powered by a 12 V battery\u003c\/li\u003e \u003cli\u003ehandheld compatible\u003c\/li\u003e \u003cli\u003efast measurement cycle\u003c\/li\u003e \u003cli\u003eservice interface\u003c\/li\u003e \u003cli\u003eexcellent signal processing via QUEST+ software\u003c\/li\u003e \u003cli\u003eHART 7 communication\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eEasyTREK Pro Non-Contact Level Transmitter for Liquids\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The EasyTREK Pro non-contact level transmitter uses ultrasonic measuring technology not only for \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003emeasuring the level\u003c\/a\u003e of liquids, but also for flow and tank volume measurement.Â The \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003eultrasonic level metering technology\u003c\/a\u003e is based on the principle of measuring the time required for the ultrasound pulses to cover the distance from the sensor to the level to be measured and back. The echoes bounce back from the surface of the medium to be measured by reaching the sensor surface after the time of flight of the ultrasonic impulse. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level, volume, or flow proportional data using the customizable tank dimensions or the preprogrammed flume \/ weir parameters. \u003ch3\u003eEasyTREK Pro Ultrasonic Level Transmitters\u003c\/h3\u003e EasyTREK ultrasonic level transmitters use \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e SenSonic range transducers with a full beam angle of 5 to 7 degrees connected to the intelligent electronics featuring the QUEST+ advanced signal processing algorithm. The intelligent QUEST+ process adaptive signal processing software system ensures that the electronics identifies and validates the liquid surface signal, giving reliable level monitoring. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cul\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/lightning-protection\/\"\u003esecondary lightning protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e32-point linearization\u003c\/li\u003e \u003cli\u003ePP, PVDF, PTFE housing and transducers\u003c\/li\u003e \u003cli\u003efail-safe indication\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazLoc rated models\u003c\/a\u003e: explosion proof, ATEX Ex ia GÂ (pending)\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cimg class=\"alignnone size-medium\" src=\"https:\/\/www.nivelco.com\/public\/files\/b1dc6bc3-bb2a-42ec-b2dd-36a965dfeef7\/11_EchoTREK.mp4\" alt=\"EchoTREK-Non-Contact-Level-Transmitter-NIVELCO\" width=\"1920\" height=\"1080\"\u003e \u003ch3\u003eSpecifications of NIVELCO EasyTrek Pro Non-Contact Level Transmitter\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e11-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e-22 to 176ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e-22 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e(absolute): 7.25-43.5 psi\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e0.49-59 ft\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e4-20 mA, HART, relay\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e1\" BSP, 1.5\", and 2\" NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e (in progress)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eEasyTREK Pro Model Line Up\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/EasyTREK-Pro-NIVELCO-ultrasonic-tank-level-measurement-metering-non-contact-level-transmitter-psc-texas-houston-stafford-model-line-up.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21694 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/EasyTREK-Pro-NIVELCO-ultrasonic-tank-level-measurement-metering-non-contact-level-transmitter-psc-texas-houston-stafford-model-line-up.jpg\" alt=\"EasyTREK-Pro-NIVELCO-ultrasonic-tank-level-measurement-metering-non-contact-level-transmitter-psc-texas-houston-stafford-model-line-up\" width=\"1000\" height=\"525\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of EasyTREK Pro Liquid Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e of liquids, wastewater, aggressive chemicals, and slurries\u003c\/li\u003e \u003cli\u003efor challenging applications such as vapor, fume, mixing blades, and light foam\u003c\/li\u003e \u003cli\u003efor liquid level measurement, open-channel flow metering\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003elevel measurement in basins,Â wells, sumps, lift-stations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003emeasuring of hydrocarbons,Â acids, water-based liquids\u003c\/li\u003e \u003cli\u003elevel and volume measurement\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/ultrasonic-radar\"\u003enon-contact level metering\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eagriculture\u003c\/li\u003e \u003cli\u003econstruction materials\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical and petrochemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epaper mill\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater industry\u003c\/a\u003e\u003cspan style=\"font-family: 'Inter var', -apple-system, BlinkMacSystemFont, 'Helvetica Neue', Helvetica, sans-serif; letter-spacing: -0.015em;\"\u003eÂ \u003c\/span\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878394683523,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EasyTREK-Pro-NIVELCO-ultrasonic-non-contact-level-transmitter-psc-texas-oklahoma-louisiana.png?v=1763385954"},{"product_id":"anacont-analytical-transmitter-for-ph-orp-dissolved-oxygen","title":"AnaCONT Analytical Transmitter for pH, ORP, Dissolved Oxygen","description":"The AnaCONT Series (LEP, LER, LED) of \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact instrumentation\u003c\/a\u003e features a liquid analytical transmitter that is suitable for high precision measurement and transmission of acidity or alkalinity. Depending on the choice of sensor, the AnaCONT Series from \u003ca href=\"https:\/\/psctexas.com\/brand\/nivelco\/\"\u003eNivelco\u003c\/a\u003e can measure: pH value (hydrogen ion concentration) [model LEP], oxidation reduction potential (ORP) reducing and oxidizing capability [model LER], or dissolved oxygen content [model LED] of \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003eprocess water, wastewater, surface water, ground water, or drinking water\u003c\/a\u003e. These measurements can be widely used in industrial systems and are of great relevance to many critical processes. In the field of \u003ca href=\"https:\/\/psctexas.com\/tag\/environmental\/\"\u003eenvironmental protection\u003c\/a\u003e or sewage treatment, the AnaCONT Series is suitable for measuring the concentration of hazardous substances (chromium or cyanide). In the \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003epharmaceutical industries\u003c\/a\u003e, high precision measurement has utmost importance in the aspect of the technology (e.g. solvent feed). And in many cases, it is quality specification standard. \u003cul\u003e \u003cli\u003e2-wire compact and integrated transmitter\u003c\/li\u003e \u003cli\u003eplug-in graphic display module\u003c\/li\u003e \u003cli\u003eseparated versions up to 33 ft\u003c\/li\u003e \u003cli\u003eapplication-oriented probes\u003c\/li\u003e \u003cli\u003ewide selection of accessories\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof models available\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUsing the AnaCONT LEP for pH Measurement\u003c\/h3\u003e Continuous measurement of acidity (pH \u0026lt; 7) and of basicity (pH \u0026gt; 7) in liquids can be performed by the help of AnaCONT transmitters. The necessary feeding of chemicals and other technological functions can be controlled by the processed measured values. The potential difference between the submerged measuring and reference probe generates a voltage proportional to the concentration of the hydrogen ion in the measured fluid. This voltage is evaluated by the signal processing electronic module of the instrument. Based on the signals of the submerged probe and the temperature sensor, the smart signal processing electronic module calculates a pH value normalized to 25Â°C and generates a proportional output signal. The long term stability and accuracy of the measurement requires a periodic calibration of the sensors using the standard buffer solutions. The pH electrode is immersed into a liquid to measure its voltage value, which is proportional to the hydrogen ion concentration of the liquid. \u003cul\u003e \u003cli\u003e0mV output at neutral pH value (pH = 7.00)\u003c\/li\u003e \u003cli\u003epositive voltage output in acidic liquids (pH \u0026lt; 7)\u003c\/li\u003e \u003cli\u003enegative voltage output in alkaline liquids (pH \u0026gt; 7)\u003c\/li\u003e \u003cli\u003etotal measuring range is 0 to 14 pH\u003c\/li\u003e \u003cli\u003e-59.16 mV\/pH (Nernst potential) slope at 25ËC\u003c\/li\u003e \u003cli\u003etemperature dependency of the Nernst potential is -0.001984 mV\/ËC\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-Nivelco-pH-Analytical-Transmitter-Process-Solutions-Corp.png\"\u003e\u003cimg class=\"aligncenter wp-image-22532 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-Nivelco-pH-Analytical-Transmitter-Process-Solutions-Corp.png\" alt=\"AnaCONT-Nivelco-pH-Analytical-Transmitter-Process-Solutions-Corp\" width=\"1000\" height=\"274\"\u003e\u003c\/a\u003e \u003ch3\u003eAnaCONT LER Analytical Transmitter for Redox Potential Measurement\u003c\/h3\u003e Similarly to the pH measurement, the measurement of the redox potential (ORP) is based on the potential difference between measuring and reference probes. Oxidation or reduction occurs on the platinum surface of the measuring probe. Redox potential is a parameter that indicates the sum of oxidants and reducers in the measured medium. The output signals of the probes are processed by the electronic unit, which converts them into a proportional output signal. In order to get the desired medium parameters, the reduction of liquids or feeding of suitable oxidant is executed based on the formerly processed values. \u003cul\u003e \u003cli\u003enegative voltage output in liquids with reduction potential\u003c\/li\u003e \u003cli\u003epositive voltage output in liquids with oxidation potential\u003c\/li\u003e \u003cli\u003eoutput voltage is equal to the redox potential (according to the Nernst equation)\u003c\/li\u003e \u003cli\u003epH independent measurement with certain types\u003c\/li\u003e \u003c\/ul\u003e To achieve reliable measurement and accuracy, these electrodes have to be thoroughly checked before installation and during usage periodically. The time interval between two calibrations depends on the application and conditions where the ORP probes are used. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-Analytical-Transmitter-ORP-Redox-Potential-Measurement-Nivelco-PSC-Texas-oklahoma-louisiana.png\"\u003e\u003cimg class=\"aligncenter wp-image-22533 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-Analytical-Transmitter-ORP-Redox-Potential-Measurement-Nivelco-PSC-Texas-oklahoma-louisiana.png\" alt=\"AnaCONT-Analytical-Transmitter-ORP-Redox-Potential-Measurement-Nivelco-PSC-Texas-oklahoma-louisiana\" width=\"1000\" height=\"225\"\u003e\u003c\/a\u003e \u003ch3\u003eAnaCONT LED for Dissolved Oxygen (DO) Measurement\u003c\/h3\u003e The dissolved oxygen (DO) measurement gives the quantity of dissolved oxygen gas in the liquid in ppm or mg\/l values. The sensor uses an oxygen-permeable membrane immersed in the liquid to provide an electronic signal proportional to the oxygen concentration. The intelligent electronics calculate and transmit the DO value, normalized to 25Â°C, on the basis of the output current of the DO sensor and the potential of the temperature sensor immersed in the medium. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/Dissolved-Oxygen-Measurement-AnaCONT-Analytical-Transmitter-Nivelco-Industrial-instrumentation-process-solutions-houston-texas.png\"\u003e\u003cimg class=\"aligncenter wp-image-22534 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/Dissolved-Oxygen-Measurement-AnaCONT-Analytical-Transmitter-Nivelco-Industrial-instrumentation-process-solutions-houston-texas.png\" alt=\"Dissolved-Oxygen-Measurement-AnaCONT-Analytical-Transmitter-Nivelco-Industrial-instrumentation-process-solutions-houston-texas\" width=\"1000\" height=\"273\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of the AnaCONT Analytical Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003epharmaceutical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003epower plants\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater quality monitoring\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewastewater treatment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003eeffluent treatment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003econtinuous dissolved oxygen measurement of \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003esurface waters\u003c\/a\u003e, aeration processes, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003eswimming pool equipment\u003c\/a\u003e, etc.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSpecifications for the Nivelco AnaCONT Analytical Transmitter\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22 to 158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e5 to 212Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure for Models LER \/ LEP\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eup to 232 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure for Model LED\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eup to 14.5 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003epH: 0-14 pH ORP: Â± 1,000 mV DO: 0-10 ppm; 0-20 ppm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, relay, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP67, IP68\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878395633795,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/AnaCONT-LED-Analytical-Transmitter-Nivelco-PSC-texas.png?v=1763385971"},{"product_id":"anacont-lck-conductivity-transmitter","title":"AnaCONT LCK, Conductivity Transmitter","description":"The AnaCONT LCK is a 2-wire, mini conductivity transmitter that is designed to measure the conductivity of a liquid and convert the input signal to 4-20 mA output. These analytical transmitters with \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact designs\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/nivelco\/\"\u003eNivelco\u003c\/a\u003e, are suitable for measuring clean, non-crystallizable liquids. The design of this transmitter, with its wide temperature range and various mounting positions, make it a good fit for a wide range of applications. \u003cul\u003e \u003cli\u003e4-20 mA, HART\u003c\/li\u003e \u003cli\u003eoptional plug-in graphic display module\u003c\/li\u003e \u003cli\u003eapplication-oriented probes\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/Wide-Range-Conductivity-Measurement-Compact-Flexible-Analytical-Transmitter-Nivelco-Online-Shop-PSC-Texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-22540 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/Wide-Range-Conductivity-Measurement-Compact-Flexible-Analytical-Transmitter-Nivelco-Online-Shop-PSC-Texas.jpg\" alt=\"Wide-Range-Conductivity-Measurement-Compact-Flexible-Analytical-Transmitter-Nivelco-Online-Shop-PSC-Texas\" width=\"1000\" height=\"275\"\u003e\u003c\/a\u003e \u003ch3\u003eEasy Mounting and Installation\u003c\/h3\u003e Due to the small dimensions and light weight of the transmitter, it can be mounted directly on tanks, pipelines, machines, and more, without any console or support.Â In open-air installations, the instrument should be protected against rain or moisture with a protection shield. To avoid disturbing signals, the housing of the instrument is grounded. If the grounding of the process is correct, no further grounding is needed. Otherwise, the instrument should be grounded at the control room side, which is strongly advised. [caption id=\"attachment_22537\" align=\"alignright\" width=\"500\"]\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-LCK-Conductivity-Transmitter-Sensing-working-principle-Nivelco-Distributor-Online-Process-Solutions-Corp-Texas.jpg\"\u003e\u003cimg class=\"wp-image-22537\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/04\/AnaCONT-LCK-Conductivity-Transmitter-Sensing-working-principle-Nivelco-Distributor-Online-Process-Solutions-Corp-Texas.jpg\" alt=\"AnaCONT-LCK-Conductivity-Transmitter-Sensing-working-principle-Nivelco-Distributor-Online-Process-Solutions-Corp-Texas\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e K=I\/A\u003cbr\u003eI = distance between electrodes\u003cbr\u003eA = electrode surface[\/caption] \u003ch3\u003eMaintenance, Repair, Working Principle of the AnaCONT Conductivity Transmitter\u003c\/h3\u003e Two probes are immersed into a liquid to be measured. The distance between the probes and their surface define the cell constant (K) of the instrument. The cell constant defines the measuring range and thus the application area. Please note that the sensor may need regular cleaning and degreasing, depending on the application, to ensureÂ proper functioning. Contaminations that remain on the probe can result in incorrect readings. Users should avoid touching the probe and keep it away from dusty environments. This conductivity transmitter does not require maintenance on a regular basis other than those mentioned above. \u003ch3\u003eCommon Uses of the AnaCONT Conductivity Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003epharmaceutical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater purification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewastewater treatment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003eeffluent treatment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003econtinuous conductivity measurement of \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003edrinking water and swimming pool equipment\u003c\/a\u003e, etc.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSpecifications for the Nivelco AnaCONT Analytical Transmitter\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAccuracy\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003etypically 3%, max 5%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e32 to 158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e14 to 158Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eup to 232 psig (16 bar)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1-20 Î¼S\/cm 10-200 Î¼S\/cm 100-2,000 Î¼S\/cm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMaterial of Wetted Parts\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eprocess connection and housing: stainless steel DIN 1.4571\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e~0.35 kg (~0.77 lb)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003evariable by order code\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP68\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eElectrical Protection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878395666563,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/AnaCONT-LCK-Conductivity-Measuring-Transmitters-Nivelco-Distributor-Liquid-Water-Quality-Monitoring-PSC-Texas-Oklahoma-Louisiana.png?v=1763385974"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/collections\/sensors-for-industrial-automation-measurement-control-universal-transmitters-pressure-transducers-level-sensors-flow-meters-process-solutions-psc-texas_d41abd8b-e51b-41d4-ade6-5d3b4c038c78.png?v=1771536183","url":"https:\/\/www.psctexas.shop\/collections\/hart-protocol.oembed","provider":"Process Solutions Corp.","version":"1.0","type":"link"}