{"title":"Hazardous Area Pressure Transducers","description":"","products":[{"product_id":"cs84-intrinsically-safe-differential-pressure-transducer-1-50-psi","title":"CS84 Intrinsically Safe Differential Pressure Transducer, 1-50 PSI","description":"The CS84 Intrinsically Safe Differential Pressure Transducer is an industrial quality \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/differential-pressure-transducers\"\u003epressure sensor for differential pressure\u003c\/a\u003e measurements. It's suitable for pressure sensing of liquids and gases in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 1 Intrinsically Safe locations\u003c\/a\u003e. Due to its all welded, \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction, the CS84 offers a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316L SS\u003c\/a\u003e oil filled sensor element provides excellent stability over a wide operating temperature range. In addition, it offers corrosion resistance against various liquids and gases. Differential pressure ranges up to 50 PSI are available with 1\/4\" MNPT or FNPT process connections. A wide range of configurable options make the CS84 a versatile pressure transducer. Moreover, it's suitable for operation in some the harshest conditions. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 1, Groups C, D T4 Approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003edifferential pressures from 1 PSI up to 50 PSI\u003c\/li\u003e \u003cli\u003eline pressures up to 500 PSI\u003c\/li\u003e \u003cli\u003ebi-directional pressure ranges available\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIntrinsically Safe Differential Pressure Transducer\u003c\/h3\u003e The CS84 Intrinsically Safe Differential Pressure Transducer is the ideal solution for \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/differential-pressure-transducers\"\u003edifferential pressure measurement\u003c\/a\u003e in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous applications\u003c\/a\u003e. For example, it's ideal for filter condition monitoring, sealed tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e, and \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow measurement\u003c\/a\u003e across an orifice. Due to its fully welded design without any internal O-rings or seals, it's well fit for wet\/wet, wet\/dry, or dry\/dry applications. Differential pressures are available from 1 to 50 PSID. In addition, it can provide both uni-directional and bi-directional pressure sensing. Multiple electrical connections and outputs are available. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Current)\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â± 0.5% BFSL \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Line Pressure\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e500 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Differential Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e50 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X or 500 PSI, \u003csmall\u003ewhichever is less, configured differential pressure\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3X configured differential pressure\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli style=\"text-align: left;\"\u003e-40 to 175ËF\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e-40 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-4 to 175ËF\u003c\/li\u003e \u003cli\u003e-20 to +80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 221ËF\u003c\/li\u003e \u003cli\u003e-40 to 105ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 131ËF\u003c\/li\u003e \u003cli\u003e0 to +55ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â± 2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â± 2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eIP Rating\u003csup\u003e4\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eIP65 minimum\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 5000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003eOutputs \u003cul\u003e \u003cli style=\"text-align: left;\"\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e Excitation \u003cul\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e Current Consumption \u003cul\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e Output Load \u003cul\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e Frequency Response (min) \u003cul\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e Zero Offset (of FS) \u003cul\u003e \u003cli\u003eâ¤ Â± 0.5% typical, Â± 1% max\u003c\/li\u003e \u003c\/ul\u003e Span Tolerance (of FS) \u003cul\u003e \u003cli\u003eâ¤ Â± 0.5% typical, Â± 1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"4\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eMax line pressure is the highest common mode pressure that can be applied to the sensor without damage. \u003csup\u003e3\u003c\/sup\u003eOverpressure and burst pressure are the maximum differential pressure that can be applied to the high or low side before damage to the sensor will occur. \u003csup\u003e4\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact factory for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eModel Number Configuration Guide for CS84 Intrinsically Safe Differential Pressure Sensor\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2019\/06\/CS84-configuration-intrinsically-safe-differential-pressure-transducer-core-sensors-psc-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23667 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2019\/06\/CS84-configuration-intrinsically-safe-differential-pressure-transducer-core-sensors-psc-texas.jpg\" alt=\"CS84-configuration-intrinsically-safe-differential-pressure-transducer-core-sensors-psc-texas\" width=\"1000\" height=\"354\"\u003e\u003c\/a\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003efiltration\u003c\/li\u003e \u003cli\u003eexternal fuel tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878365094019,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs84-IS-intrinsically-safe-differential-pressure-sensor-core-sensors-psc-texas.png?v=1763385187"},{"product_id":"cs74-intrinsically-safe-temperature-transmitter-depreciated","title":"CS74 Intrinsically Safe Temperature Transmitter (depreciated)","description":"Features: \u003cul\u003e \u003cli\u003eCSA Class 1, Division 1, Groups C and D, T3\u003c\/li\u003e \u003cli\u003eClass 1, Zone 1 AEx ia IIC T4 Gb\u003c\/li\u003e \u003cli\u003eWide configurable temperature ranges from -40 to +200Â°C\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.4% BFSL accuracy\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878365126787,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS74.png?v=1763385188"},{"product_id":"cs51-non-incendive-low-pressure-transducer-1-49-psi","title":"CS51 Non-Incendive Low Pressure Transducer, 1-49 PSI","description":"The CS51 Non-Incendive Low Pressure Transducer is a high strength sensor for low pressure measurements in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass 1, Division 2 hazardous locations\u003c\/a\u003e. The CS51 features an all welded \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction that offers a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS51, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, a versatile \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/hazloc-pressure-transducers\"\u003ehazardous location pressure transducer\u003c\/a\u003e that's capable of operating in some of the harshest conditions. The CS51 is an excellent solution for applications such as \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e, external fuel tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e, and process control instrumentation. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003eno conduit installation necessary\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/li\u003e \u003cli\u003epressures from 1 to 49 PSI\u003c\/li\u003e \u003cli\u003esee \u003ca href=\"https:\/\/psctexas.com\/product\/cs50-non-incendive-pressure-transducer\/\"\u003emodel CS50\u003c\/a\u003e for pressures 50 PSI and above\u003c\/li\u003e \u003cli\u003emedia isolated\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS51 Non-Incendive Low Pressure Transducer\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS51 Non-Incendive Low Pressure Transducer offers an integral Turck Minifast electrical connection. When combined with a CSA Division 2 approved \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck cordset\u003c\/a\u003e and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. You can \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003elearn more about the Turck Minifast electrical connection here: http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e *We recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23745 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration.jpg\" alt=\"CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration\" width=\"1000\" height=\"359\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eApprovals and Certifications for this Non-Incendive Low Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of the CS51\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003evapor recovery\u003c\/li\u003e \u003cli\u003eprocess controls\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372270211,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385487"},{"product_id":"cs54-non-incendive-differential-pressure-transducer-1-50-psi","title":"CS54 Non-Incendive Differential Pressure Transducer, 1-50 PSI","description":"The CS54 Non-Incendive Differential Pressure Transducer is a high strength sensor for differential pressure measurements of liquids and gases in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 2 hazardous locations\u003c\/a\u003e. A \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316L SS oil filled sensor\u003c\/a\u003e element provides excellent stability over a wide operating temperature range. In addition, this \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure transducer\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers corrosion resistance against various liquids and gases. Differential pressure ranges up to 50 PSI are available with 1\/4\" MNPT or FNPT process connections. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/hazloc-pressure-transducers\"\u003ehazardous area pressure sensors\u003c\/a\u003e in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003eno conduit installation necessary\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/li\u003e \u003cli\u003edifferential pressures from 1 to 50 PSI\u003c\/li\u003e \u003cli\u003eline pressures up to 500 PSI\u003c\/li\u003e \u003cli\u003ebi-directional pressure ranges available\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS54 Non-Incendive Differential Pressure Sensor\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS54 Non-Incendive Differential Pressure Transducer offers an integral Turck Minifast electrical connection. When combined with a CSA Division 2 approved \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck\u003c\/a\u003e cordset and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. You can \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003elearn more about the Turck Minifast electrical connection here: psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e \u003cb\u003e*\u003c\/b\u003eWe recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e Not all configurations are available. Our sales team can recommend the closest available configuration based on your requirements.Â Contact us for configurations not shown. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23737 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\" alt=\"CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations\" width=\"1000\" height=\"319\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of the CS54 Non-Incendive Differential Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003efiltration\u003c\/li\u003e \u003cli\u003ecryogenic bulk tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ecompression systems\u003c\/li\u003e \u003cli\u003etest stands\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372335747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385489"},{"product_id":"cs80-intrinsically-safe-pressure-transducer-50-30000-psi","title":"CS80 Intrinsically Safe Pressure Transducer, 50-30,000 PSI","description":"\u003cp\u003eThe CS80 Intrinsically Safe Pressure Transducer is a high strength sensor for use in Class I, Division 1 intrinsically safe areas. The CS80 features an all welded stainless steel construction for a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS80, from Core Sensors, a versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/pressure-transducers\" title=\"Pressure Transducers from Core Sensors\"\u003epressure transducer\u003c\/a\u003e that can operate in some the harshest conditions.\u003c\/p\u003e\n\u003cp\u003eLow power outputs are available which can operate off of 3-5 VDC of unregulated power to extend battery life in remote applications. The CS80 is an excellent solution for applications such as natural gas compression and oil exploration. Caution must be taken when installing and operating hazardous area pressure sensors in known Class I, Division 1 locations. Please review the Intrinsically Safe Operating Instructions prior to installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eplug and play installation\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups C, D T4 approval\u003c\/li\u003e\n\u003cli\u003epressures from 50 to 30,000 PSI\u003c\/li\u003e\n\u003cli\u003esee model CS81 for pressures below 50 PSI\u003c\/li\u003e\n\u003cli\u003eone piece design\u003c\/li\u003e\n\u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCS80 Intrinsically Safe Pressure Transducer\u003c\/h2\u003e\n\u003cp\u003eWe offer a variety of high quality accessories to bundle with the CS80 Intrinsically Safe Pressure Transducer to simplify installation. Common accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emating cordsets\u003c\/li\u003e\n\u003cli\u003efield wireable mating connectors\u003c\/li\u003e\n\u003cli\u003ecooling adapters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eAccuracy @ 77˚F (25˚C)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% BFSL\u003c\/li\u003e\n\u003cli\u003e≤ ±0.5% BFSL \u003csmall\u003e(\u0026gt; 10,000 PSI)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003cli\u003e≤ ±1% BFSL \u003csmall\u003e(Millivolt output signal)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% of FS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e100 million\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2X minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5X or 60,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 176˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 80˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection “F”, DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-4 to 176˚F\u003c\/li\u003e\n\u003cli\u003e-20 to 80˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 257˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 125˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection “F”, DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 221˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 105˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e32 to 131˚F\u003c\/li\u003e\n\u003cli\u003e0 to 55˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 257˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 125˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eYes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP Rating\u003c\/a\u003e\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eIP65 minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eLow Power\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eMillivolt\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e20 mA, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~250 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e1-5 V\u003c\/li\u003e\n\u003cli\u003e1-6 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-4.5 V ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC ±0.5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ 3 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 mV\/V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026gt; 1 M Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~5 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eApprovals and Certifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\" target=\"_blank\" title=\"CSA Group\"\u003eCSA Class I, Division 1, Groups C, D T4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga)\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/webstore.ansi.org\/standards\/ul\/ul122701ed2017\" target=\"_blank\" title=\"ANSI\"\u003eANSI\/UL 122701 Single Seal certification\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" title=\"American Bureau of Shipping\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" title=\"CE Marking\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE\u003c\/strong\u003e: Users must use an approved barrier to maintain listed certifications. See page 4 of the data sheet for entity parameters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Uses of the CS80 I.S. Pressure Sensor\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003enatural gas compression\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil exploration\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eprocess controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372368515,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS80-Intrinsically-Safe-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385490"},{"product_id":"cs81-intrinsically-safe-low-pressure-transducer-1-49-psi","title":"CS81 Intrinsically Safe Low Pressure Transducer, 1-49 PSI","description":"\u003cp\u003eThe CS81 Intrinsically Safe Low Pressure Transducer is a high strength sensor for low pressure measurements in intrinsically safe areas. The CS81 features an all welded stainless steel construction for a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options makes the CS81, from Core Sensors, a versatile pressure transducer that can operate in some of the harshest conditions. Low power outputs are available which can operate off of 3-5 VDC of unregulated power to extend battery life in remote applications. The CS81 is an excellent solution for applications such as external fuel tank monitoring, vapor recovery, and natural gas compression. Caution must be taken when installing and operating hazardous area instrumentation in known Class I, Division 1 locations. Please review the Intrinsically Safe Operating Instructions prior to installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eplug and play installation\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups C, D T4 approval\u003c\/li\u003e\n\u003cli\u003epressures from 1 to 49 PSI, see model CS80 for pressures 50 PSI and above\u003c\/li\u003e\n\u003cli\u003emedia isolated\u003c\/li\u003e\n\u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCS81 Intrinsically Safe Low Pressure Transducer\u003c\/h2\u003e\n\u003cp\u003eWe offer a variety of high quality accessories to bundle with the CS81 Intrinsically Safe Low Pressure Transducer to simplify installation. Common accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emating cordsets\u003c\/li\u003e\n\u003cli\u003efield wireable mating connectors\u003c\/li\u003e\n\u003cli\u003ecooling adapters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications for the CS81 Low Pressure Transducer\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eAccuracy @ 77˚F (25˚C)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% BFSL\u003c\/li\u003e\n\u003cli\u003e≤ ±0.5% BFSL \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003cli\u003e≤ ±1% BFSL \u003csmall\u003e(Millivolt output signal)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% of FS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e100 million\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2X minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5X or 245 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 176˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 80˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection “F”, DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-4 to 176˚F\u003c\/li\u003e\n\u003cli\u003e-20 to 80˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 257˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 125˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection “F”, DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 221˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 105˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e32 to 131˚F\u003c\/li\u003e\n\u003cli\u003e0 to 55˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 257˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 125˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003cli\u003e≤ ±2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003cli\u003e≤ ±2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eYes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP Rating\u003c\/a\u003e*\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eIP65 minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eLow Pressure\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eMillivolt\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e20 mA, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~250 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e1-5 V\u003c\/li\u003e\n\u003cli\u003e1-6 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-4.5 V ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC ±0.5 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ 3 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 mV\/V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026gt; 1 M Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~5 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eApprovals and Certifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\" target=\"_blank\" title=\"CSA Group\"\u003eCSA Class I, Division 1, Groups C, D T4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga)\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" title=\"American Bureau of Shipping\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" title=\"CE Marking\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE\u003c\/strong\u003e: Users must use an approved barrier to maintain listed certifications. See page 4 of the data sheet for entity parameters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Uses of the CS81\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eexternal fuel tank level measurement\u003c\/li\u003e\n\u003cli\u003evapor recovery\u003c\/li\u003e\n\u003cli\u003eprocess controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372401283,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS81-Intrinsically-Safe-Low-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385491"},{"product_id":"cs82-intrinsically-safe-submersible-pressure-transducer-1-50-psi","title":"CS82 Intrinsically Safe Submersible Pressure Transducer, 1-50 PSI","description":"The CS82 Intrinsically Safe Submersible Pressure Transducer is a high strength sensor for liquid \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurements\u003c\/a\u003e in intrinsically safe locations. This \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/submersible-pressure-transducers\/\"\u003esubmersible pressure sensor\u003c\/a\u003e features \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e (316L and 304) construction and an ETFE cable jacket for compatibility with a wide variety of liquids. Precision welds and a high strength Nylon strain relief prevent liquids from entering the transducer. And a wide diameter vent tube quickly equalizes the barometric pressure within the sensor body to ensure accurate level measurements. The CS82, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, is available in various output signals including 4-20 mA loop power for long distance transmissions and voltage outputs for low power and low current consumption applications. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e. Please review the Intrinsically Safe Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003ereliable \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eliquid level measurement\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003epressures from 1 to 50 PSI\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eCSA Class I, Division 1, Groups C, D T4 approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eETFE cable jacket with wide diameter vent tube\u003c\/li\u003e \u003cli\u003eNylon strain relief, Buna-N form seal, \u003ca href=\"https:\/\/www.viton.com\/en\" target=\"_blank\" rel=\"nofollow noopener\"\u003eViton O-ring\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS82 Intrinsically Safe Submersible Pressure Transducer\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-23713 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs82-intrinsically-safe-IS-submersible-pressure-sensor-core-sensors-level-measurement-psc-texas-249x300.jpg\" alt=\"cs82-intrinsically-safe-IS-submersible-pressure-sensor-core-sensors-level-measurement-psc-texas\" width=\"249\" height=\"300\"\u003eThe CS82 Intrinsically Safe Submersible Pressure Transducer is certified by CSA to operate safely in \u003ca href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eClass I, Division 1 Intrinsically Safe locations\u003c\/a\u003e when used with an approved current limiting barrier. This transducer features a high strength 300 series stainless steel (304 \u0026amp; 316L) metallic construction, corrosion resistant ETFE cable jacket, and a Nylon strain relief for compatibility in a wide range of liquids. \u003col\u003e \u003cli\u003eWhile a nose cone comes standard on the CS82 Intrinsically Safe Submersible Pressure Transducer. Configurations are available with 1\/4\" or 1\/2\" Male NPT for threaded installation in flood prone areas.\u003c\/li\u003e \u003cli\u003eLow power configurations are available when utilizing the CS82 in remote locations or where supply voltage is limited. Ask us for more information!\u003c\/li\u003e \u003cli\u003eStandard and custom cable lengths are available to simplify installation.\u003c\/li\u003e \u003c\/ol\u003e   \u003ch3\u003eHighly Configurable IS Submersible Pressure Sensor\u003c\/h3\u003e The CS82 features a configurable design, allowing us to tailor the \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure transducer\u003c\/a\u003e to your applications operating requirements. Do you have a limited voltage supply at your installation? No problem! The CS82 is available in a low power configuration, so it's capable of operating from an unregulated power supply of 3-5 VDC while consuming 3 mA or less of current. Need an extra long \u003ca href=\"https:\/\/psctexas.com\/product-category\/cables\/\"\u003ecable length\u003c\/a\u003e? No problem! We offer both standard and custom cable lengths to ensure you have enough cable to simplify your installation In addition, the CS82 Intrinsically Safe Submersible Pressure Transducer is great for non-submersible applications. The standard nose cone can be substituted for 1\/4\" or 1\/2\" Male NPT threads for threaded installation. This is a common practice where flooding is a concern. \u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 1, Groups C, D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eNOTE\u003c\/strong\u003e: Users must use an approved barrier to maintain listed certifications. See page 4 of the data sheet for entity parameters. \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs82-intrinsically-safe-submersible-pressure-transducer-core-sensors-level-measurement-process-solutions-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23715 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs82-intrinsically-safe-submersible-pressure-transducer-core-sensors-level-measurement-process-solutions-texas.jpg\" alt=\"cs82-intrinsically-safe-submersible-pressure-transducer-core-sensors-level-measurement-process-solutions-texas\" width=\"1000\" height=\"323\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of this Intrinsically Safe Submersible Pressure Sensor\u003c\/h3\u003e \u003cul\u003e \u003cli\u003efuel tank level measurement\u003c\/li\u003e \u003cli\u003eballast tanks\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003eflood monitoring\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003edepth measurement\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372434051,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs82-intrinsically-safe-submersible-pressure-transducer-core-sensors-level-measurement-process-solutions-corp.png?v=1763385492"},{"product_id":"cs50-non-incendive-pressure-transducer-50-30000-psi","title":"CS50 Non-Incendive Pressure Transducer, 50-30,000 PSI","description":"The CS50 Non-Incendive Pressure Transducer is a high strength \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure sensor\u003c\/a\u003e for use in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 2 hazardous locations\u003c\/a\u003e. The CS50 features an all welded \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction, offering a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS50 a versatile pressure transducer that's able to operate in some of the harshest conditions. The CS50 is an excellent solution for applications such as \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/tag\/hydrogen-industrial-gas\/\"\u003ehydrogen compression and storage\u003c\/a\u003e, and process control instrumentation. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epressures from 50 to 30,000 PSI\u003c\/li\u003e \u003cli\u003esee \u003ca href=\"https:\/\/psctexas.com\/product\/cs51-non-incendive-low-pressure-transducer-core-sensors\/\"\u003emodel CS51\u003c\/a\u003e for pressures below 50 PSI\u003c\/li\u003e \u003cli\u003eone piece design\u003c\/li\u003e \u003cli\u003eno conduit installation required\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS50 Non-incendive Pressure Transducer\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS50 Non-Incendive Pressure Transducer, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers an integral \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck\u003c\/a\u003e Minifast electrical connection. In combination with a CSA Division 2 Turck cordset and Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. Click here to learn more about the \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast electrical connection here: psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e *We recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.5% BFSL \u003csmall\u003e(\u0026gt;10,000 PSI)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X minimum\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5X or 60,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 176ËF\u003c\/li\u003e \u003cli\u003e-40 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-4 to 176ËF\u003c\/li\u003e \u003cli\u003e-20 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 221ËF\u003c\/li\u003e \u003cli\u003e-40 to 105ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 131ËF\u003c\/li\u003e \u003cli\u003e0 to 55ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP Rating\u003c\/a\u003e\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 minimum\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eElectrical Specifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eLow Power\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e1-5 V\u003c\/li\u003e \u003cli\u003e1-6 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-4.5 V ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 VDC Â±0.5 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign='\"top'\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ 3 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eHazardous Area Approvals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2 Groups A,BC,D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/webstore.ansi.org\/standards\/ul\/ul122701ed2017\" target=\"_blank\" rel=\"nofollow noopener\"\u003eANSI\/UL 122701 Single Seal\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eConfiguration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23705 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\" alt=\"cs50-non-incendive-pressure-transducer-core-sensors-psc-texas-configuration\" width=\"1000\" height=\"367\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of the CS50 Non-incendive Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003enatural gas compression\u003c\/li\u003e \u003cli\u003eoil exploration\u003c\/li\u003e \u003cli\u003eprocess controls\u003c\/li\u003e \u003cli\u003ehydrogen (316L SS only)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878377054339,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs-50-non-incendive-pressure-transducer-core-sensors-process-solutions-corp.png?v=1763385565"},{"product_id":"cs60-explosion-proof-pressure-transducer","title":"CS60 Explosion Proof Pressure Transducer","description":"\u003cp\u003eThe CS60 series is a high strength explosion-proof pressure transducer for use in Class I, Division 1 hazardous locations. Available output signals include configurations as a voltage output transducer or 4-20mA transmitter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D, T4 Approval\u003c\/li\u003e\n\u003cli\u003eConfigurable pressure ranges from 50 PSI up to 30,000 PSI\u003c\/li\u003e\n\u003cli\u003eOne piece diaphragm design - No internal O-rings or welds\u003c\/li\u003e\n\u003cli\u003eIndependent 4-20mA or voltage temperature output available\u003c\/li\u003e\n\u003cli\u003eFactory sealed stainless steel case - Withstands harsh environments\u003c\/li\u003e\n\u003cli\u003eAssembly in New Jersey, USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003eClass I Div I Explosion-Proof Pressure Sensor\u003c\/h2\u003e\n\u003cp\u003eReliable explosion-proof pressure measurement starts with the sensing element. Utilizing bulk silicon piezoresistive technology, CS60 pressure sensor elements are manufactured from a single piece of stainless steel or high strength nickel alloy (such as Hastelloy C276 or Inconel 718); this combination creates a robust combination of accurate, repeatable sensing with a range of liquid and gas compatibility.\u003c\/p\u003e\n\u003cp\u003eCS60 explosion-proof pressure transducers feature an all-welded, factory sealed stainless steel construction, offering a minimum IP-66 rating. A 1\/2\" Male NPT conduit fitting with 2 meters of 20AWG flying leads is standard, allowing for easy installation of rigid metal conduit. A wide operating temperature range and configurable design makes the CS60 a versatile pressure transducer that was engineered to operate in some the harshest conditions. The CS60 series is an excellent solution for applications such as well head pressure measurement, natural gas compressors and oil exploration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eIndependent Temperature Output Signal Available\u003c\/h2\u003e\n\u003cp\u003eConfigure your explosion-proof pressure transducer with an independent temperature output signal as well. The CS60 can be configured with a 4-20mA or voltage temperature output signal. The temperature is based on a platinum RTD temperature sensor mounted near the sensor diaphragm. Save time and money with an integrated amplified temperature output within your pressure transducer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWellhead pressure measurement\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; Gas Panels\u003c\/li\u003e\n\u003cli\u003eOil exploration and production\u003c\/li\u003e\n\u003cli\u003eHydrogen filling stations\u003c\/li\u003e\n\u003cli\u003ePipeline equipment\u003c\/li\u003e\n\u003cli\u003eCompression\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878421192835,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs60-explosion-proof-pressure-transducers-industrial-quality-process-solutions-corp.png?v=1763386409"},{"product_id":"cs64-explosion-proof-differential-pressure-transducer","title":"CS64 Explosion Proof Differential Pressure Transducer","description":"\u003cul\u003e \u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D, T4 Approval\u003c\/li\u003e \u003cli\u003econfigurable differential pressure ranges from 1 PSI up to 50 PSI\u003c\/li\u003e \u003cli\u003eline pressures up to 500 PSI\u003c\/li\u003e \u003cli\u003ewet\/wet\u003c\/li\u003e \u003cli\u003efactory seal stainless steel case Â to withstand harsh environments\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e TheÂ CS64 Explosion Proof Differential Pressure TransducerÂ is a high strength sensor for \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/differential-pressure-transducers\"\u003edifferential pressure measurements\u003c\/a\u003e of liquids and gases in Class I, Division 1 explosion-proof locations. The CS64, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, features an all-welded, factory seal stainless steel construction and a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP66 rating\u003c\/a\u003e. A 316L SS oil-filled sensor element provides excellent stability over a wide operating temperature range. Additionally, this offers corrosion resistance against various liquids and gases. A 1\/2\" Male NPT conduit fitting with 2 meters of 20AWG flying leads is standard. This fitting allows for easy installation of rigid metal conduit. Differential pressure ranges from 1 PSI up to 50 PSI are available with 1\/4\" Female NPT process connections. \u003ch3\u003eSpecifications for the CS64 Explosion Proof Differential Pressure Sensor\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Current)\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Voltage)\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 25Â°C\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â± 0.5% BFSL \u003csmall\u003e(2 PSI and below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Line Pressure\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e500 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Differential Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e50 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X or 500 PSI, \u003csmall\u003ewhichever is less, configured differentialÂ pressure range\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3X configured differential pressure range\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 185ËF\u003c\/li\u003e \u003cli\u003e-40 to 85ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 248ËF\u003c\/li\u003e \u003cli\u003e-40 to 120ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 to 149ËF\u003c\/li\u003e \u003cli\u003e-15 to 65ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â± 2% of FS \u003csmall\u003e(2 PSI and below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â± 2% of FS \u003csmall\u003e(2 PSI and below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP Rating\u003c\/a\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP66\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e1-5 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"5\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eMax line pressure is the highest common mode pressure that can be applied to the sensor without damage. \u003csup\u003e3\u003c\/sup\u003eOverpressure and burst pressure are the maximum differential pressure that can be applied to the high or low side before damage to the sensor will occur.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eExplosion-Proof\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D, T4\u003c\/li\u003e \u003cli\u003eClass I Zone 1 AEx db IIC T4 Gb\u003c\/li\u003e \u003cli\u003eEx db IIC T4 Gb\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eDust Ignition-Proof\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eClass II, Division 1, Groups E, F and G, T135Â°C\u003c\/li\u003e \u003cli\u003eZone 21 AEx tb IIIC T135Â°C Db\u003c\/li\u003e \u003cli\u003eEx tb IIIC T135Â°C Db\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOther Approvals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eConfiguration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/08\/cs64-explosion-proof-pressure-sensors-configuation-guide-psc-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23555 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/08\/cs64-explosion-proof-pressure-sensors-configuation-guide-psc-texas.jpg\" alt=\"cs64-explosion-proof-pressure-sensors-configuation-guide-psc-texas\" width=\"1000\" height=\"335\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of Explosion Proof Differential Pressure Sensors\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003ewellhead pressure measurement\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil exploration\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003epipeline equipment\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/\"\u003epower generation\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878421225603,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs64-explosion-proof-differential-pressure-transducer-core-sensors-distributor-psc-texas.png?v=1763386410"}],"url":"https:\/\/www.psctexas.shop\/collections\/hazardous-area-pressure-transducers.oembed","provider":"Process Solutions Corp.","version":"1.0","type":"link"}