{"title":"Industrial Flow Meters","description":"","products":[{"product_id":"inline-flow-meter-master-touch-series-86008700-mp-haz","title":"Inline Flow Meter, Master-Touch Series 8600-8700 MP HAZ","description":"\u003cp\u003eThe 8600-8700 MP Inline Flow Meter Series provides accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" rel=\"nofollow noopener\" target=\"_blank\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaster-Touch Series 8600-8700 MP HAZ, Inline Flow Meter\u003c\/h3\u003e\n\u003cp\u003eMaster-Touch Series products include a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. Then it is controlled by the temperature sensor and bridge circuitry. Furthermore, our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003ch3\u003e8600-8700 Series Inline Flow Meter for Use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazardous Locations\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cp\u003eOur inline flow meter for thermal mass flow measurement includes a flow section that is usually specified to match the userâs flow conduit and is then plumbed directly into the process line. This design also has the sensing elements mounted directly in the flow section for exposure to the process gas. This thermal mass flow inline flow meter is available in sizes from 1\/4\" pipe through 4\" pipe or tube and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as necessary. Pipe sizes more than 4\" typically require insertion style thermal mass flow meters. This integral style inline flow meter has all the electrical components and connections located within one enclosure. Additionally, this enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003ch3\u003eOperating Principle\u003c\/h3\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Furthermore, our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. In addition, our microcontroller operate with smart sensor technology that preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, which causes an increase in the power necessary to maintain a balance between the RTDs. As a result, this increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes. So, the output signal is a true mass flow rate signal.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8600â8700 MP HAZ\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26148 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\" alt=\"Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp\" width=\"750\" height=\"513\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eCertifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApprovals\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Orientation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Housing\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003ePipe Information\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 4\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 6\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e), Multi-Range + Temp Out, Multi-Range + No Temp, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eBACnet\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eProfibus\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e (when applicable): Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMounting Requirements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMNPT Ends\u003c\/li\u003e\n\u003cli\u003eButt End\u003c\/li\u003e\n\u003cli\u003eFlange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSensor Wetted Materials Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eStainless Steel 316L\u003c\/li\u003e\n\u003cli\u003eHastelloy C-276\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364340355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp_60549b24-6b99-4485-bd1a-d8863121157d.png?v=1763385157"},{"product_id":"eldridge-products-valumass-series-500-val-inline-flow-meter","title":"Eldridge Products, ValuMass Series 500 VAL Inline Flow Meter","description":"ValuMass 500 VAL flow meters provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, is undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. Like the ValuMass Series 540, the ValuMass Series 500 inline \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flowmeter\u003c\/a\u003e also uses the proprietary temperature compensation techniques using two RTD (resistance temperature detectors). This design allows the ValuMass Series to deliver accurate measurements day in, day out. If you require reliable mass measurement for an air and gas flow application with an inline installation, the ValuMass Series 500 is an excellent choice that provides great value at a great price. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26153 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch3\u003eThermal Mass Flow Meters\u003c\/h3\u003e ValuMass 500 Series VAL is a rugged, cleanable, thermal mass flow sensor. These flow meters consist of a sensor assembly that utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors rely upon a ceramic substrate that then receives a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged as well as relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. In addition, it is controlled by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003e500 Series Flow Meter from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e\n\u003c\/h3\u003e Our inline style thermal mass flow meters include a flow section that matches the userâs flow conduit and then usually plumbs directly into the process line. Furthermore, the sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2.5\" pipe. The 3.5\" long flow sections have MNPT ends as standard for easy mounting in the process line (options available for pipe sizes over 2.5\"). Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure features a rating for non-hazardous environments. Then the enclosure mounts directly to the inline flow section assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eOperation Principle\u003c\/h3\u003e Thermal mass flow meters from Eldridge Products use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options Eldridge Products - ValuMass 500 Series VAL\u003c\/h3\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003ePipe Information\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 2.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 3.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus RTU\u003c\/a\u003e), \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e: Standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e: 0-5, 0-10\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMounting Requirements\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eMNPT Ends\u003c\/li\u003e \u003cli\u003eButt End\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Wetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eStainless Steel 316L\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364405891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-ValuMass-Inline-Thermal-Mass-Flow-Meter-500-VAL-EPI-Process-Solutions-Corp.png?v=1763385160"},{"product_id":"psc-controlled-evaporation-system-vapor-generation","title":"PSC Controlled Evaporation System, Vapor Generation","description":"Our vapor generation systems offer a user-friendly, color touchscreen interface for easy vapor generation control. Its programming allows users to easily control flow rates, setpoints, temperature, stop\/start, and concentration \/ composition of the vapor stream. Input \/ Output is also conveniently available on the control unit to allow users to easily connect various \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow meters and flow controllers\u003c\/a\u003e, change carrier gas, and process liquids. \u003cul\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/bronkhorst-draft\/\"\u003eBronkhorst\u003c\/a\u003e: \u003ca href=\"https:\/\/psctexas.com\/product\/controlled-evaporator-mixer\/\"\u003eCEM\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003egas and liquid flow meters and controllers\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003einternal temperature safety switch\u003c\/li\u003e \u003cli\u003eheat tracing\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e interface, ethernet enabled\u003c\/li\u003e \u003cli\u003euser-friendly, 7\" color touchscreen interface for easy control\u003c\/li\u003e \u003cli\u003edata logging and \u003ca title=\"WebMI\" href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e capabilities\u003c\/li\u003e \u003cli\u003ecomputer, phone, or tablet access\u003c\/li\u003e \u003c\/ul\u003e https:\/\/youtube.com\/shorts\/yD2DSdIZros \u003ch3\u003eApplications Benefitting from Precision Vapor Generation\u003c\/h3\u003e The low flow capabilities of our CEM Controller makes for an easy, all-in-one vapor generation system. This evaporation system is an especially useful device for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003elaboratories, research purposes\u003c\/a\u003e, and intricate \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/manufacturing\/\"\u003emanufacturing processes\u003c\/a\u003e. Common applications includeÂ \u003ca title=\"Flow Meters In The Food Industry\" href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eprecise batching of additives in food and beverage manufacturing\u003c\/a\u003eÂ andÂ \u003ca title=\"Use of Mass Flow Meters in the automotive industry\" href=\"https:\/\/psctexas.com\/use-of-mass-flow-meters-in-the-automotive-industry\/\"\u003echemical vapor deposition (CVD) processes\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eanalyzers with reference gas vapor concentrations toxic gas\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/camping-applications-that-are-made-possible-with-mass-flow-control\/\"\u003eeffects on protective clothing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eanalyzers with reference H\u003csmall\u003e2\u003c\/small\u003eO vapor concentrations\u003c\/li\u003e \u003cli\u003eanesthetics\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/humidification-of-fuel-cells\/\"\u003ehumidification of fuel cells\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ecrystal breeding installations\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003edosage of additives, e.g. perfume, vitamins, etc.\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/tag\/semiconductor\/\"\u003esemiconductor\u003c\/a\u003e and solar cell manufacturing for electric and dielectric (insulating) layer deposition\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003cimg class=\"alignright wp-image-24331 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2021\/12\/vapor-generation-system-controlled-evaporation-mixer-cem-vaporizer-generator-process-solutions-corp-woocommerce-300x300.png\" alt=\"vapor-generation-system-controlled-evaporation-mixer-cem-vaporizer-generator-process-solutions-corp\" width=\"300\" height=\"300\"\u003eTable Top Model\u003c\/h3\u003e Our vapor generation systems are available in either table top \/ desk top models or as a rack-mounted unit. The table top unit can control one CEM system and allows users to easily move and store the vapor generator when not in use. This set up is ideal for research laboratories, universities, and other places where the vapor generation system may not be in constant use and\/or where space is limited. \u003ch3\u003e\n\u003cimg class=\"alignright wp-image-24532 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/05\/rack-mounted-controlled-evaporation-mixer-vapor-generation-system-process-solutions-corp-300x286.png\" alt=\"rack-mounted-controlled-evaporation-mixer-vapor-generation-system-process-solutions-corp\" width=\"300\" height=\"286\"\u003eRack Mounted Vapor Generation System\u003c\/h3\u003e The rack mount system is ideal for manufacturing environments and offers the same easy control. Unlike the table top unit, the rack mount CEM Controller can independently control up to three different vapor generation systems via three separate evaporator mixers and supplemental flow controllers for gases and liquids. In addition, the rack mount vapor generation system can control all three systems as part of a single system. \u003ch3\u003eAdvantages over Traditional Bubbler Systems\u003c\/h3\u003e The CEM Controller offers highly accurate, repeatable, and also efficient vapor generation and analytical tracking. Traditionally, \u003ca href=\"https:\/\/psctexas.com\/benefits-of-using-a-controlled-evaporation-vs-a-bubbler\/\"\u003ebubbler systems are often not capable of handling sufficient quantities of liquid with a low vapor pressure\u003c\/a\u003e, or perform in an imperfect way. Moreover, they cannot instantaneously provide vapor of a mixture of liquids with different vapor pressures. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/10\/CEM-Diagram-Vapor-Generation-System-Controlled-Evaporation-Mixing-Process-Solutions-Corp.png\"\u003e\u003cimg class=\"alignright wp-image-24336 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/10\/CEM-Diagram-Vapor-Generation-System-Controlled-Evaporation-Mixing-Process-Solutions-Corp.png\" alt=\"CEM-Diagram-Vapor-Generation-System-Controlled-Evaporation-Mixing-Process-Solutions-Corp\" width=\"992\" height=\"1000\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eCEM Controller for Vapor Generation\u003c\/h3\u003e This vapor generation system is a modular setup with theÂ \u003ca href=\"https:\/\/psctexas.com\/cem\/\"\u003eControlled Evaporative Mixer (CEM)\u003c\/a\u003e itself as the core component. A CEM is a mixer and vaporizer that uses heat to atomize a liquid, which is then mixed with a carrier gas. The carrier gas and liquid mixture is then heated and transformed into vapor phase, which can then be used for precise, low flow vapor control. And to feed the CEM with liquid and gas, the CEM is setup with a \u003ca href=\"https:\/\/psctexas.com\/how-to-handle-low-liquid-flows\/\"\u003eliquid flow meter\u003c\/a\u003e with a control function and a \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\"\u003egas flow controller\u003c\/a\u003e. The liquid flow meter also uses the mixing valve of the CEM to control the liquid flow rate. \u003ch3\u003eControlled Evaporation Technology\u003c\/h3\u003e The gas serves as a mixing component and as a means of transport for the vapor and is therefore known as carrier gas. The mixing valve atomizes the liquid and adds it to the carrier gas, creating an aerosol, which is heated by the CEM until it transforms into a vapor. To monitor the internal temperature of the heat exchanger, the CEM incorporates a PT100 temperature sensor. Additionally, an internal safety switch prevents overheating of the heat exchanger, by interrupting the control signal as soon as the temperature reaches 392ËF.\u003cspan class=\"Apple-converted-space\"\u003eÂ \u003c\/span\u003e \u003ch3\u003eAll-in-One Vapor Generation Device\u003c\/h3\u003e To control the liquid and gas supply flows and the CEM temperature, the CEM Controller integrates the flow instrumentation with a user-friendly, color touchscreen interface that also serves as a power supply unit. In addition, the controller comes equipped with Modbus interface programmed for the CEM system. The CEM Controller also contains a temperature controller for heat tracing purposes. Furthermore, the CEM controller allows for data logging of instrument data and WebMI capabilities. \u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI empowers users to control everything onscreen from a computer, tablet, or other mobile devices.\u003cspan class=\"Apple-converted-space\"\u003eÂ \u003c\/span\u003e\u003c\/a\u003e \u003ch3\u003eReady-to-Use \/ Out-the-Box Packages Available:\u003c\/h3\u003e \u003col\u003e \u003cli\u003e7â Color Touchscreen interfaceÂ âÂ \u003ci\u003eProcess control, monitoring, data logging, remote access\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/controlled-evaporator-mixer\/\"\u003eControlled Evaporation Mixer (CEM)\u003c\/a\u003e â \u003cem\u003eT\u003c\/em\u003e\u003ci\u003eemperature and heating, vaporizer, mixing chamber\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003eHeat Tracing â \u003ci\u003eControl temperature through outlet\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003eHeat Tracing Temperature Verification â \u003ci\u003eProcess temperature thermocouple connection\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\"\u003eLiquid Meter and Controller\u003c\/a\u003e â \u003ci\u003eRemote control outlet\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\"\u003eGas Controller\u003c\/a\u003e â \u003ci\u003eRemote control outlet\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003eMini-USB Connection â\u003cem\u003e Program PLC\u003c\/em\u003e\n\u003c\/li\u003e \u003cli\u003eUSB Connection â \u003ci\u003eData transfer or storage\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus\u003c\/a\u003e MJ2 - Power (+) â \u003ci\u003ecommunicates and powers meters\/controllers\u003c\/i\u003e\n\u003c\/li\u003e \u003cli\u003eModbus MJ3 \u003cul\u003e \u003cli\u003e\u003cem\u003eadditional Modbus RTU communication port\u003c\/em\u003e\u003c\/li\u003e \u003cli\u003e\u003cem\u003edoes not control CEM system\u003c\/em\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eEthernet Lan1 \u003cul\u003e \u003cli\u003e\u003cem\u003eProgram PLC\u003c\/em\u003e\u003c\/li\u003e \u003cli\u003e\u003cem\u003eAdditional communication port\u003c\/em\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ePower with on\/off Switch\u003c\/li\u003e \u003cli\u003eAdditional Ports\u003c\/li\u003e \u003c\/ol\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\/\"\u003eGas Flow Controller\u003c\/a\u003e\u003c\/h5\u003e The choice of \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\/\"\u003egas flow controller\u003c\/a\u003e depends on the specific requirements of the application. The gas flow controller is used to supply carrier gas to the CEM for the vaporization of the desired liquid. Common choices include thermal mass flow meters such as the \u003ca href=\"https:\/\/psctexas.com\/product\/el-flow-prestige-mass-flow-meters-controllers-for-gases-mfm-mfc\/\"\u003eEL-FLOW Prestige\u003c\/a\u003e or \u003ca href=\"https:\/\/psctexas.com\/product\/in-flow-high-flow-thermal-mass-flow-meters-controllers-for-gases\/\"\u003eIN-FLOW for higher flow rates\u003c\/a\u003e orÂ \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis based flow meters\u003c\/a\u003e such as the \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-coriolis-mass-flow-meters-controllers\/\"\u003emini CORI-FLOW\u003c\/a\u003e. Our engineers will work with you to help determine which \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eBronkhorst flow meter\u003c\/a\u003e will work best for your process. \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\/\"\u003eLiquid Flow Meter\u003c\/a\u003e\u003c\/h5\u003e The choice of \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\/\"\u003eliquid flow meter and controller\u003c\/a\u003e is typically a \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-coriolis-mass-flow-meters-controllers\/\"\u003emini CORI-FLOW\u003c\/a\u003e since this instrument offers unmatched precision and functional capability. Additionally, the mini CORI-FLOW can handle a wide range of liquids of various viscosities and corrosive properties. This device is used to precisely supply the CEM with liquid for the vaporization process. However, other flow instrumentation may be chosen depending on the specific requirements of the user and application. \u003ch5\u003e\n\u003ca href=\"https:\/\/www.bronkhorst.com\/getmedia\/4d1d7267-fa66-48da-be4f-8f643a43e3fd\/W-202A_\"\u003e\u003cimg class=\"alignright size-medium\" src=\"https:\/\/www.bronkhorst.com\/getmedia\/4d1d7267-fa66-48da-be4f-8f643a43e3fd\/W-202A_\" alt=\"CEM-Controlled-Evaporation-Mixer-for-Vapor-Generation\" width=\"398\" height=\"419\"\u003e\u003c\/a\u003eControlled Evaporative Mixer (CEM)\u003c\/h5\u003e The CEM is the heart of the controlled evaporation system. This device is equipped with an atomizer, which is used to vaporize the liquid, which is then mixed with the carrier gas in the mixing chamber. \u003ch5\u003eColor Touchscreen Interface\u003c\/h5\u003e As a standard, our Vapor Generation Controller features a 7â color touchscreen interface for an indication of measured values. Additionally, the controller offers user-friendly process control and includes high functionalities specifically for vapor generation processes. The touchscreen easily enables the user to change the setpoints as well as other functions. The controller also powers the devices and communicates via Modbus to control the CEM temperature and the instruments' flow rates. In addition, the controller offers a temperature traced vapor outlet and the option for additional gas or liquid instruments.","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878380953731,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/rack-mounted-vapor-generation-system-cem-controlled-evaporation-vaporizer-atomizer-laboratory-precise-vapor-delivery-bronkhorst-distributor-psc-texas.png?v=1763385602"},{"product_id":"psc6000-operation-controller-with-touch-screen-hmi","title":"PSC6000 Operation Controller with Touch Screen HMI","description":"The PSC6000 flow control system is preprogrammed with standard features, making this a great plug-and-play option for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/manufacturing\/\"\u003emanufacturers\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003euniversities and research or analytical labs\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage producers\u003c\/a\u003e, cosmetic and \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003epharmaceutical production\u003c\/a\u003e, and more. Since there is no programming required, this operation controller is ideal for users with little or no programming experience. In addition to standard features, our engineers can program custom parameters and functions on the PSC6000 Operations Controller, depending on specific customer and application requirements. Standard features include: \u003cul\u003e \u003cli\u003eflow rate\u003c\/li\u003e \u003cli\u003etotalizer\u003c\/li\u003e \u003cli\u003eset point\u003c\/li\u003e \u003cli\u003ebatch operations\u003c\/li\u003e \u003cli\u003eeasy to access connections\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eEthernet Enabled Flow Control System\u003c\/h3\u003e In addition to including both digital and analog output options, the built-in HMI is \u003ca href=\"https:\/\/psctexas.com\/tag\/ethernet-enabled\"\u003eethernet enabled\u003c\/a\u003e, which allows remote access and monitoring along with data logging. Moreover, this flow control system is equipped with a USB port and Micro SD card slot, so you can save your process data at any time. The touch screen interface offers 640x480 high-resolution resistive touch and isÂ programmed to be user-friendly. Also, it includes 32,000 colors and support for multiple languages.\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/mini-CORI-FLOW-ML120.jpg\"\u003e\u003cimg class=\"size-medium wp-image-1624 alignright\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/mini-CORI-FLOW-ML120-300x226.jpg\" alt=\"mini-CORI-FLOW-meter-bronkhorst-flow-instrumentationML120\" width=\"300\" height=\"226\"\u003e\u003c\/a\u003e The PSC6000 uses \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus\u003c\/a\u003e to communicate with and control flow instrumentation such as \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eflow meters and controllers manufactured by Bronkhorst\u003c\/a\u003e. Our most popular choice is the \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-coriolis-mass-flow-meters-controllers\/\"\u003eMini CORI-FLOW\u003c\/a\u003e, which a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\"\u003ecompact\u003c\/a\u003e, highly accurate \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis flow meter\u003c\/a\u003e that is capable of handling both \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\"\u003egas\u003c\/a\u003e or \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\"\u003eliquid flows\u003c\/a\u003e. Also available is theÂ \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-ex-d-coriolis-mass-flow-meters-controllers-hazloc\/\"\u003eMini CORI-FLOW Ex d Series\u003c\/a\u003e, which is suitable for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e.   \u003ch3\u003eUses of the PSC6000 Operation Controller\u003c\/h3\u003e Since it features numerous data logging functions, the PSC6000 is ideal for low flow processes that require record keeping. In addition to helping minimize waste of raw materials, this operations controller is great for optimizing low flow applications, including continuous flow processes. Also, with Batch Operation programming built-in, this flow control unit is sure to keep production consistent between batches and helps when scaling batch size. \u003ch3\u003eApplications Requiring Precise Low Flow Process Control\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUniversities, Research Labs and Analytical Laboratories \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-solution-for-hydrogen-storage\/\"\u003eHydrogen Storage\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-role-of-flow-control-in-hydrogen-production\"\u003eHydrogen Production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-gas-flow-control-for-analytical-instruments\/\"\u003eStable Gas Flow for Analytical Instrumentation\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/benchtop-bioreactors-and-gas-flow-control\"\u003eReliable Biological Growth in Benchtop Bioreactors\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\/\"\u003eVaccine research\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-mass-flow-controller-can-support-in-the-pharmaceutical-industry\/\"\u003ePharmaceutical research\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-control-in-gas-chromatography\/\"\u003eFlow Control in Gas Chromatography processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/calibrating-gas-chromatographs-with-gas-flow-controllers\"\u003eGas Chromatograph calibrations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-to-improve-your-gas-chromatography-analysis\/\"\u003eImproving Gas Chromatography analysis\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/inductively-coupled-plasma-icp-for-environmental-analysis\"\u003eInductively Coupled Plasma for Environmental Analysis\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/low-flow-control-for-corrosion-protection\/\"\u003eProtection against Corrosion\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eManufacturers \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-and-fast-gas-flow-control-for-vacuum-deposition\/\"\u003eVacuum Deposition processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-dosing-with-flow-meters\/\"\u003eLiquid Dosing applications\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/best-dye-dosing-systems\/\"\u003eDye Dosing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/metering-pump-performance-improved-with-flow-meters\"\u003eImproving Metering Pump performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-can-you-improve-your-dosing-pump-performance-with-flow-meters\/\"\u003eImproving Dosing Pump performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003eCommon Flow Meter and Dosing Pump combinations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/dosing-pump-control-for-improved-batching\/\"\u003eBatch Production using Dosing Pumps\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\/\"\u003emRNA Vaccine production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/aeration-in-fish-farming\"\u003eAeration in Fish Farming\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/mass-flow-meter-to-enhance-water-processing\"\u003eReliable Water Treatment processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/vapor-and-liquid-flow-control-for-aseptic-packaging\"\u003eLiquid Control in Aseptic Packaging\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-flow-controllers-for-bacterial-growth-in-bioreactors\/\"\u003eFermented Food and Drink production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eIngredient Dosing in Foods and Beverages\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-importance-of-flow-control-in-chocolate-production\"\u003eIngredient Dosing in Chocolate production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/what-role-do-flow-meters-play-in-processing-sugar-beets\"\u003eProcessing Sugar Beets\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/camping-applications-that-are-made-possible-with-mass-flow-control\/\"\u003eManufacturing of supplies for Camping\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-control-for-air-duct-leakage-test\/\"\u003eAir Duct Leakage Testing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/space-suit-testing\"\u003eTesting of Space Suits\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/accurate-dosing-of-release-agent\/\"\u003eManufacturing using Plastic Moulds\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/use-of-mass-flow-meters-in-the-automotive-industry\"\u003eManufacturing of Automobiles\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\"\u003eBlending Homogeneous Gas Mixtures\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-supply-using-a-pressure-vessel\"\u003eLiquid Supply using a Pressure Vessel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/catalytic-treatment-of-volatile-organic-compounds\/\"\u003eCatalytic Treatment of VOCs\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/controlled-co2-supply-for-algae-cultivation\"\u003eCO\u003csmall\u003e2\u003c\/small\u003e Production for Algae Cultivation\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-and-fast-gas-flow-control-for-vacuum-deposition\"\u003eVacuum Deposition by Reactive Sputtering\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878381052035,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Operation-Controller-PSC-6000-Texas-Flow-Control-e1631024292675.png?v=1763385605"},{"product_id":"kayden-classic-800-series-switch-and-transmitter","title":"Kayden CLASSIC 800 Series, Switch and Transmitter","description":"\u003cp\u003eThe CLASSIC 800 Series features switches and transmitters for flow, level, interface, and temperature process control. Each model has a precision welded, highly accurate stainless steel thermal sensor. The \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 800 Series is ideal for liquids, gases, and slurries in clean or dirty processes. Options for process connections include: raised face, RTJ flange, threaded, or retractable packing glands. In addition, all Kayden CLASSIC models feature a rugged flameproof enclosure with blind or lens cover options. Its advanced digital electronics will revolutionize the way you monitor and control your process.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e\n\u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e\n\u003cli\u003etemperature compensation\u003c\/li\u003e\n\u003cli\u003euniversal power 12-24 VDC and 115-230 VAC standard\u003c\/li\u003e\n\u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e\n\u003cli\u003e4-20 mA analog output\u003c\/li\u003e\n\u003cli\u003esmart heater function for power economy and increased heater life\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKayden CLASSIC 800 Series Model Line Up\u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003eKayden CLASSIC 810 - Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections - MNPT\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1\/2 inch, 3\/4 inch, 1.0 inches, 1 1\/4 inches, 1 1\/2 inches, 2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-812-flanged-thermal-sensor-flow-meter-level-switch-and-transmitter-interface\/\"\u003eKayden CLASSIC 812 - Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814 - Flanged Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eretractable packing gland, raised face, or RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816 - Threaded Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethreaded retractable packing gland (1\" MNPT)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830 - In-Line Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832 - In-Line Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Kayden CLASSIC 800 Series*\u003c\/h3\u003e\n\u003cp\u003e*options vary by model selection\u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow\u003c\/li\u003e\n\u003cli\u003elevel\u003c\/li\u003e\n\u003cli\u003einterface\u003c\/li\u003e\n\u003cli\u003etemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eProcess Connections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003cli\u003eflanged in-line\u003c\/li\u003e\n\u003cli\u003e MNPT\n\u003cul\u003e\n\u003cli\u003e1\/2 inch\u003c\/li\u003e\n\u003cli\u003e3\/4 inch\u003c\/li\u003e\n\u003cli\u003e1 inch\u003c\/li\u003e\n\u003cli\u003e1-1\/4 inches\u003c\/li\u003e\n\u003cli\u003e1-1\/2 inches\u003c\/li\u003e\n\u003cli\u003e2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 to 3.5 inches Tri-Clamp\n\u003cul\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003cli\u003esanitary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eretractable packing glands\n\u003cul\u003e\n\u003cli\u003ethreaded (1” MNPT)\u003c\/li\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSanitary Tri-Clamp Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eFlanged Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h4\u003e\n\u003cp\u003eStandard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1.2 inches (3 cm)\u003c\/li\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003cli\u003e9 inches (23 cm)\u003c\/li\u003e\n\u003cli\u003e12 inches (30 cm)\u003c\/li\u003e\n\u003cli\u003e18 inches (45 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKayden CLASSIC 828 (Sanitary)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCustom Lengths\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e\n\u003cli\u003eKayden CLASSIC model dependent: minimum 1.2 inches (3 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInput Power Options\u003c\/h4\u003e\n\u003cp\u003eUniversal Power Standard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12-24 VDC\u003c\/li\u003e\n\u003cli\u003e115-230 VAC\u003c\/li\u003e\n\u003cli\u003e50-60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConsumption\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emaximum: 6.0 watts (fully configured)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4-20 mA current loop\u003c\/li\u003e\n\u003cli\u003etwo (2) independent SPDT sealed relay contacts\n\u003cul\u003e\n\u003cli\u003erated at 4 amps resistive 230 VAC or 30 VDC maximum\u003c\/li\u003e\n\u003cli\u003eindividually adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAccuracy\u003c\/h4\u003e\n\u003cp\u003eFlow Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±1% set point velocity over operating range of ±50˚F (±28˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLevel Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±0.25 inches (±0.64 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResponse Time\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eapproximately 0.5 to 30 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRemote Electronics Options\u003c\/h4\u003e\n\u003cp\u003eMaximum Recommended \u003ca href=\"https:\/\/psctexas.com\/product-category\/cables\/\"\u003eCable Length\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200 feet (60 meters)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCable Type\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 AWG minimum\u003c\/li\u003e\n\u003cli\u003etwisted pairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHeater Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003efield adjustable to optimize performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStart Up Bypass Timer\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable for 0 to 100 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e via RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Pressure (Maximum)\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 MPa (3500 psig) dependent on Kayden CLASSIC model and material of construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTemperature Range (Sensor)\u003c\/h4\u003e\n\u003cp\u003eContinuous Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-50 to 392˚F (-45 to 200˚C)\u003c\/li\u003e\n\u003cli\u003e-40 to 320˚F (-40 to 160˚C) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectronics\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-67˚F to 149˚F (-55˚C to 65˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: For temperatures above 149˚F (65˚C), electronics must be remotely mounted. Storage\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Kayden CLASSIC models should be stored in a clean and dry environment between -34.5 to 140˚F (-30 to 60˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnclosure Material\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecopper-free aluminum (does not exceed 0.4% copper)\u003c\/li\u003e\n\u003cli\u003epowder coated polyester TGIC (polyester triglycidyl isocyanurate)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4\u003c\/a\u003e \/ Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1” FNPT conduit connection\u003c\/li\u003e\n\u003cli\u003ebuna o-ring on cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConduit Connection Cover\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWetted Materials\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e - standard\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e grade 2\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e316\/316L stainless steel with nickel braze [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003ehighly saturated nitrile (pressure seal) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003eother wetted material options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003erated:\n\u003cul\u003e\n\u003cli\u003e120 Vac max\u003c\/li\u003e\n\u003cli\u003e30 Vdc max\u003c\/li\u003e\n\u003cli\u003e4A max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, Insertion Style\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 3.0 feet\/second (0.003 to 0.9 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 5.0 feet\/second (0.003 to 1.5 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.25 to 254 sfps (0.076 to 77 smps)\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, In-Line Models\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.015 to 50 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.033 to 110 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.6 to 20,000 cc\/second\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C ) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eRCMS (Remote Control \u0026amp; Monitoring Software) Functions and Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edisplay panel lock-out\u003c\/li\u003e\n\u003cli\u003eset points configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003erelay actuation delay timer\u003c\/li\u003e\n\u003cli\u003eindependently configurable for both on and off \/ increasing or decreasing\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 5,000 seconds\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 100 seconds\u003c\/li\u003e\n\u003cli\u003erelay mode configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eenergized above or below set point\u003c\/li\u003e\n\u003cli\u003erelay temperature mode configuration\u003c\/li\u003e\n\u003cli\u003eheater power setting\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ezero and span settings\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eanalog (4-20 mA) output configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eview and print graphing (trend) function\u003c\/li\u003e\n\u003cli\u003econfiguring settings; write to device, save to file, and print\u003c\/li\u003e\n\u003cli\u003efault event log\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003ealso configurable from display panel\u003c\/p\u003e\n\u003ch4\u003eWeights and Dimensions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003e810 threaded\u003c\/a\u003e: 2\" 'U' length: 7 pounds (3.18 kg)\u003c\/li\u003e\n\u003cli\u003ecarton size: 15x5x6 inches (38x13x15 cm)\u003c\/li\u003e\n\u003cli\u003eother models\/sizes: \u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us for more information\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWarranty\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eone (1) year from shipment date from factory (see full Terms and Conditions for details)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDisplay Panel Indicators\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003erelay 1 and 2\u003c\/li\u003e\n\u003cli\u003eset point 1 and 2\u003c\/li\u003e\n\u003cli\u003efault alarm\u003c\/li\u003e\n\u003cli\u003erun mode\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration Mode Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable sensitivity\u003c\/li\u003e\n\u003cli\u003ezero and span adjustment\u003c\/li\u003e\n\u003cli\u003eModbus addressable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eprimary watchdog circuit monitors microprocessor parameter anomalies\u003c\/li\u003e\n\u003cli\u003esecondary watchdog circuit monitors microprocessor health\u003c\/li\u003e\n\u003cli\u003eheater monitored for out-of-range conditions\u003c\/li\u003e\n\u003cli\u003efault mode de-energizes relay(s) and halts power to the heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApprovals and Certifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\"\u003eCSA Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eANSI\/UL Class I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eEx d IIB + H2\u003c\/li\u003e\n\u003cli\u003eAEx d IIB+H2 (Class I, Zone 1, Group IIB + H2,) T3\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSingle Seal Approval\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePer \u003ca rel=\"nofollow noopener\" href=\"https:\/\/webstore.ansi.org\/\" target=\"_blank\"\u003eANSI\u003c\/a\u003e\/ISA 12.27.01-2003\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\"\u003eFM Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 1, AEx d IIB+H2 T2D (Ta=75˚C) \/ T3 (Ta=65˚C)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCRN Canadian Registration Number\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCRN approvals available\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us\u003c\/a\u003e for CRN information per model and jurisdiction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003ch2 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h2\u003e\n\u003ch4\u003eFlow\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow switch for pump protection - dry alarm\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etank overflow protection\u003c\/li\u003e\n\u003cli\u003eflare gas monitoring\u003c\/li\u003e\n\u003cli\u003emonitoring purge air flow\u003c\/li\u003e\n\u003cli\u003elube oil systems\u003c\/li\u003e\n\u003cli\u003event monitoring\u003c\/li\u003e\n\u003cli\u003enatural gas to boilers\u003c\/li\u003e\n\u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e\n\u003cli\u003edrain line flow\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etanker loading and unloading\u003c\/li\u003e\n\u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e\n\u003cli\u003eremote indication of flow via analog and digital output communications\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLevel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003estorage tanks\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e\n\u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e\n\u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e\n\u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e\n\u003cli\u003etank overflow\u003c\/li\u003e\n\u003cli\u003esampler systems\u003c\/li\u003e\n\u003cli\u003esand separators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInterface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003econtrol in separation vessels\u003c\/li\u003e\n\u003cli\u003edetection\u003c\/li\u003e\n\u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMedia\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eliquids, air, and gases\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e\n\u003cli\u003eslurries\u003c\/li\u003e\n\u003cli\u003ecorrosive liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eProcess Conditions for this Switch \/ Transmitter for Flow, Level, Interface, and Temperature\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eFlow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003eclean and dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eLevel\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003cli\u003enon-turbulent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eInterface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003edry gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878381183107,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-800-Series-Flow-Meter-Level-Switch-Interface-Switches-Temperature-Transmitter-Process-Solutions-Texas.png?v=1763385608"},{"product_id":"gas-mixing-chamber","title":"Gas Mixing Chamber","description":"\u003cp\u003eOur Gas Mixing Chambers enable precision creation of \u003ca href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\" title=\"Gas Mixing Chambers for Homogeneous Gas Mixtures\" target=\"_blank\"\u003ehomogeneous gas mixtures\u003c\/a\u003e essential for analytical, laboratory, and industrial applications. Unlike simple gas blending, producing a true homogeneous mixture requires specially designed chambers to thoroughly mix individual flows with minimal turbulence and maximum repeatability. This is especially true when combining significantly different flow rates such as low-dosing gas with a high-volume carrier.\u003c\/p\u003e\n\u003cp\u003eOur gas mixing chambers, from \u003ca title=\"Bronkhorst Low Flow Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/bronkhorst\"\u003eBronkhorst\u003c\/a\u003e, integrate seamlessly with mass \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Meters and Controllers\"\u003eflow meters and controllers\u003c\/a\u003e, thus ensuring accurate, consistent composition from trace levels up to practical process flows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eflow ranges from 300 ml\u003csmall\u003en\u003c\/small\u003e\/min up to 10,000 ml\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e\n\u003cli\u003efor creating homogeneous gas mixtures from percentages down to ppm ranges\u003c\/li\u003e\n\u003cli\u003eavailable with 1\/4\" or 6 mm connections\u003c\/li\u003e\n\u003cli\u003epressure rating up to 20 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eGas Mixing Chambers for Blending Your Own Homogenous Gas Mixtures\u003c\/h2\u003e\n\u003cp\u003eOur gas mixing chambers are ideal for use in calibration gas generation, environmental and surface treatment systems, process control loops, or any setup demanding stable mixed gas streams. These gas mixing chambers help eliminate compositional gradients, thus improving measurement reliability and performance quality. Robustly constructed for compatibility with a wide range of gases, Bronkhorst gas mixing chambers support flexible system design while enhancing uniform blending without compromising flow integrity.\u003c\/p\u003e\n\u003cp\u003eTheir compact footprint allows easy installation into existing gas delivery systems, and our technical support team and engineers can assist in selecting optimal configurations tailored to specific flow ranges and applications. Unlock greater precision with our gas mixing solutions, your foundation for consistent, homogeneous gas blends in critical applications.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas.jpg?v=1771512477\" alt=\"Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"Bronkhorst","offers":[{"title":"1\/4\" OD Compression","offer_id":46603716100227,"sku":"7.01.188","price":665.0,"currency_code":"USD","in_stock":true},{"title":"6 mm OD Compression","offer_id":46603716132995,"sku":"7.01.446","price":665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Gas-Mixing-Chamber_bronkhorst-flow-instrumentation-meters-flow-controllers-shop-online-process-solutions.png?v=1763385913"},{"product_id":"liquid-dosing-system","title":"Liquid Dosing System","description":"\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eOur liquid dosing system eliminates the guess work in the dosing of liquids such as dyes and chemicals to fuels, water, and in manufacturing applications. Our dosing systems can be designed to accommodate any flow rate requirements and also offer a wide range of liquid handling capability including corrosive liquids. The color \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003etouchscreen controller\u003c\/a\u003e provides an intuitive, user-friendly interface with built-in security and safety features such as password protection, alarming, and quick shutdown. This dosing systems also includes manual mode for testing, troubleshooting, and calibration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003efully loaded, user-friendly touchscreen interface with custom functions available\u003c\/li\u003e\n\u003cli\u003ebudget-friendly, flexible designs that can accommodate a variety of liquid types, flow rates, and installation requirements\u003c\/li\u003e\n\u003cli\u003estand-alone, rack-mount, table-top, in-line \/ on-site, and portable dosing system options\u003c\/li\u003e\n\u003cli\u003efully automatic operation with alarming and quick shutdown\u003c\/li\u003e\n\u003cli\u003eautomatic Totalizing Mode for pumping a specific volume in addition to batch dosing\u003c\/li\u003e\n\u003cli\u003eautomatic Run Mode for pumping a volumetric ratio in real time\u003c\/li\u003e\n\u003cli\u003emanual mode operation for testing, troubleshooting, as well as calibration\u003c\/li\u003e\n\u003cli\u003euniversal supply by AC or DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFully Automated Liquid Dosing System\u003c\/h2\u003e\n\u003cp\u003eWith in-house assembly in Houston, Texas, our engineers will work closely with your team to design and build the ultimate liquid dosing system for your application. Our systems are available in standalone, rack-mount, portable, table-top, as well as in-line or on-site stationary designs. As a result, our liquid dosing systems can fit most any dosing application and environment. We can also write custom functions or operations into the programming to fit your exact application requirements and make your process seamless and hands-off. The flexibility of our dosing systems also allows a wide range of flow rates, viscosities, corrosive liquids, and more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehigh accuracy (from ppm to high-flow injection)\u003c\/li\u003e\n\u003cli\u003erepeatable batch consistency\u003c\/li\u003e\n\u003cli\u003eintegration with PLC\/SCADA systems\u003c\/li\u003e\n\u003cli\u003eimproves safety and reduces operator error (reduces material handling)\u003c\/li\u003e\n\u003cli\u003ereduces chemical waste and operational costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOffering a Variety of Styles and Sizes\u003c\/h2\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg height=\"500\" width=\"500\" style=\"margin-left: 25px; float: right;\" alt=\"Liquid-Dosing-Pump-for-Manufacturing-Process-Analyzer-Rooms-Diesel-Fuel-Blending-Bronkhorst-Flow-Instrumentation-Process-Solutions-Corp-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Liquid-Dosing-Pump-for-Manufacturing-Process-Analyzer-Rooms-Diesel-Fuel-Blending-Bronkhorst-Flow-Instrumentation-Process-Solutions-Corp-Texas.png?v=1771521538\"\u003e\u003c\/div\u003e\n\u003cp\u003eStand-alone units can include a sunshield and sun-readable display, thus making it suitable for use outdoors. This is also useful in harsh environments where the touchscreen HMI needs protection when not in use, such as on marine vessels. Table-top versions are ideal for laboratories and \u003ca title=\"Analyzer Solutions\" href=\"https:\/\/www.psctexas.shop\/collections\/analyzer-solutions\"\u003eanalyzer\u003c\/a\u003e rooms and can easily be transported or stored when not in use. Our in-line and on-site units are ideal for manufacturing applications, gas sampling system automation, gas processing, and other continuous or batch dosing processes. Portable units can be built in custom \u003ca title=\"Pelican Cases\" rel=\"nofollow noopener\" href=\"https:\/\/www.pelican.com\/us\/en\/\" target=\"_blank\"\u003ePelican\u003c\/a\u003e cases; thus allowing easy transportation while offering sufficient protection from the environment or other damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Applications for Liquid Dosing Systems\u003c\/h2\u003e\n\u003cp\u003eThis automated dosing system is ideal for batching or continuous dosing of additives to fuels such as diesel blending, automating sampling systems in analyzer rooms, or for manufacturing processes. Liquid dosing systems are useful in gas processing facilities, refineries, pilot plants, analyzer rooms, drill sites, in food and beverage production facilities, as well as offshore on rigs or ships. Common industrial uses include water in diesel applications, dosing of chemicals to fuels, and dosing chemicals such as chlorine to wastewater streams. Furthermore, out dosing systems are useful for applying coatings to machinery parts, adding dyes and flavors to food and beverages, and much more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and Energy\n\u003cul\u003e\n\u003cli\u003emarine fuel blending (viscosity modifiers, lubricity additives)\u003c\/li\u003e\n\u003cli\u003ediesel and gasoline additive injection\u003c\/li\u003e\n\u003cli\u003ecorrosion inhibitors for example in pipelines\u003c\/li\u003e\n\u003cli\u003ebiodiesel blending\u003c\/li\u003e\n\u003cli\u003emethanol injection (hydrate prevention)\u003c\/li\u003e\n\u003cli\u003edemulsifiers \/ emulsion breakers\u003c\/li\u003e\n\u003cli\u003escale inhibitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater Treatment\n\u003cul\u003e\n\u003cli\u003echlorine and disinfectant dosing\u003c\/li\u003e\n\u003cli\u003epH adjustment (acid\/caustic)\u003c\/li\u003e\n\u003cli\u003ecoagulants and flocculants\u003c\/li\u003e\n\u003cli\u003ecooling tower chemical treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eChemical Processing\n\u003cul\u003e\n\u003cli\u003ecatalyst injection\u003c\/li\u003e\n\u003cli\u003epolymer additives\u003c\/li\u003e\n\u003cli\u003ereaction control chemicals\u003c\/li\u003e\n\u003cli\u003ebatch blending operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and Beverage\n\u003cul\u003e\n\u003cli\u003eflavor and dye dosing\u003c\/li\u003e\n\u003cli\u003epreservatives and other additives\u003c\/li\u003e\n\u003cli\u003ecleaning-in-place (CIP) chemicals\u003c\/li\u003e\n\u003cli\u003ecarbonated beverage additives\u003c\/li\u003e\n\u003cli\u003ebioreactors and fermentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePharmaceuticals and Biotechnology\n\u003cul\u003e\n\u003cli\u003enutrient feeds in bioreactors\u003c\/li\u003e\n\u003cli\u003esterile reagent dosing\u003c\/li\u003e\n\u003cli\u003ebuffer and media preparation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurface Treatment and Industrial Cleaning\n\u003cul\u003e\n\u003cli\u003eacid baths\u003c\/li\u003e\n\u003cli\u003eelectroplating chemicals\u003c\/li\u003e\n\u003cli\u003edetergent dosing\u003c\/li\u003e\n\u003cli\u003erust inhibitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eLiquid Dosing System with Intuitive Controls and Seamless Process Control\u003c\/h2\u003e\n\u003cp\u003eFeaturing a touchscreen interface, our liquid dosing systems are reliable, effective, easy to control, and ready to use upon arrival. The user-friendly programming includes full functionality such as automatic operation and totalizing mode. Being built in-house in Houston, Texas, our dosing units can include additional physical or programmable features to meet the unique operation, safety, and environmental requirements of your application.\u003c\/p\u003e\n\u003cp\u003eFurthermore, automatic operation doesn't mean it's not monitored. Our liquid dosing systems include alarming to help prevent operational errors. It also features a quick shutdown function to ensure safety and to provide operators with ultimate control. Alarms can even be delivered via text, email, beacon lights on the unit, as well as audible alerts. Password protection is also included to ensure these dosing systems can't be easily tampered with or accidentally modified. In addition to automated functions, our dosing units feature a manual operation mode, which allows operators to test, troubleshoot, and calibrate the unit, thus providing ultimate control over the dosing system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eUniversal Liquid Dosing System with Fast Production\u003c\/h2\u003e\n\u003cdiv class=\"flex flex-col text-sm\"\u003e\n\u003carticle data-turn=\"assistant\" data-scroll-anchor=\"true\" data-testid=\"conversation-turn-14\" data-turn-id=\"request-WEB:0c3b5ea9-6422-4678-95c2-33108e8c0a56-6\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" dir=\"auto\" data-message-id=\"4d7cbfd9-e4f9-4a9e-8d0f-3cead97904d8\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling\"\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"688\" data-start=\"0\"\u003eOur automated liquid dosing systems are engineered for flexibility because no two applications are the same. Rather than forcing you into a one-size-fits-all solution, the standard design of our dosing systems allow easy customization to fit your exact process requirements. With a universal power supply that operates on AC or DC, these units are ready for deployment anywhere, whether onshore, offshore, in-field, or at sea. The modular design supports a wide range of pump technologies, thus allowing accurate dosing of virtually any liquid at nearly any flow rate or viscosity. From standard fluids to aggressive or corrosive chemicals, our systems deliver precision, reliability, and performance wherever you need it most.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eComplete Control over Liquid Dosing Processes\u003c\/h2\u003e\n\u003cp\u003eIn addition to being intuitive and user-friendly, the control interface on our liquid dosing systems are extremely versatile and far from basic. Aside from the modifiable, preprogrammed functions, the controller also offers powerful data logging with remote access and monitoring capabilities. It can even display multiple languages! \u003ca title=\"Send Us an Email\" href=\"mailto:sales@psctexas.com\"\u003eGet in touch\u003c\/a\u003e with us today to speak to our engineering and design team about your process needs and let us come up with a unique, effective, and affordable solution for you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eRelated Technologies\u003c\/h2\u003e\n\u003ch4\u003eFlow Controller and Readout for Existing Instrumentation\u003c\/h4\u003e\n\u003cp\u003eAlready own the pumps, flow meters, and flow controllers? Check out our plug-and-play flow controller: the \u003ca title=\"FlowLogic Readout and Flow Controller\" href=\"https:\/\/www.psctexas.shop\/products\/flowlogic-flow-control-system-readout\"\u003eFlowLogic\u003c\/a\u003e readout and flow control system. This flow controller and readout system eliminates the need for using a laptop, thus allowing easy operation, configuration, and control of any digital flow instrumentation \/ system. The FlowLogic can control up to four flow meters or controllers and includes advanced, built-in functions such as totalizer mode, continuous operation mode, measured value, set point, and much more. This flow controller includes the indication and operation of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasured Value\u003c\/li\u003e\n\u003cli\u003eSetpoint\u003c\/li\u003e\n\u003cli\u003eInstrument Range\u003c\/li\u003e\n\u003cli\u003eTrending Values Totalizer (limit, value, totalizer mode, new setpoint)\u003c\/li\u003e\n\u003cli\u003eas well as custom programmable functions to meet your requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVapor Generation System\u003c\/h4\u003e\n\u003cp\u003eIf generating a vapor stream is what you really need, check out our \u003ca title=\"Vapor Generation Systems from Process Solutions Corp.\" href=\"https:\/\/www.psctexas.shop\/products\/psc-controlled-evaporation-system-vapor-generation\"\u003eVapor Generation Systems\u003c\/a\u003e. The precision control and \u003ca title=\"Low Flow Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\"\u003elow flow\u003c\/a\u003e capabilities of our controlled evaporation technology makes for an easy, all-in-one vapor generation system. It's an especially useful device for laboratories, research, as well as for intricate manufacturing processes. These systems include up to 3 \u003ca title=\"Gas Flow Meters\" href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\"\u003egas flow meters\u003c\/a\u003e, \u003ca title=\"Liquid Flow Meters\" href=\"https:\/\/www.psctexas.shop\/collections\/liquid-flow-meters-and-controllers\"\u003eliquid flow meters\u003c\/a\u003e and controllers, and \u003ca title=\"CEM Series, Controlled Evaporation Mixers\" href=\"https:\/\/www.psctexas.shop\/products\/cem-evaporator-series-controlled-evaporator-mixer\"\u003evaporizers\u003c\/a\u003e and integrated mixing chamber. Our vapor generation systems are available in table-top versions or they can integrated in-line to a new or existing manufacturing, gas sampling, or similar processes where highly repeatable and accurate vapor generation is mandatory.\u003c\/p\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878391701635,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Liquid-Dosing-System-Fuel-Blending-Automated-Totalizing-Dosing-Systems-Manufacturing-Diesel-Dosing-Process-Solutions-Corp-PSC-Texas.png?v=1771521348"},{"product_id":"liquid-dosing-pumps","title":"Liquid Dosing Pumps","description":"We offer a wide range of dosing pumps to suit a large variety of applications. From gallons per minute for handling large quantities of water, to grams per hour for analytical and research purposes, to specialized materials for handling corrosive substances, we can provide the instrumentation and engineering support required for optimal efficiency and performance. \u003cul\u003e \u003cli\u003elow flow dosing pumps\u003c\/li\u003e \u003cli\u003eWADose high pressure pumps\u003c\/li\u003e \u003cli\u003egear pumps\u003c\/li\u003e \u003cli\u003eother pumps available upon request\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eLow Flow Dosing Pumps\u003c\/h3\u003e Our low flow dosing pumps can handle fluids in the microliter to milliliter range for small volumetric flows. These ultra low flow pumps are often necessary for analytical processes, laboratory research, in the chemistry lab, in biotechnology processes such as bioreactors, pharmaceutical production and research, and even in mechanical engineering. To ensure process fidelity, our low flow dosing pumps offer high stability. For example, our micro-annular gear pumps use technology that opens doors to a wide range of applications. Our engineering team will be happy to assist you with design, pump selection, and even in-person training for your staff. We'll even help you select the right connectors, filters, adaptors, and other sensors necessary for your process. \u003ch5\u003eMicro Annular Gear Pumps\u003c\/h5\u003e \u003cul\u003e \u003cli\u003elow shear stress\u003c\/li\u003e \u003cli\u003elow pulsation\u003c\/li\u003e \u003cli\u003elight weight and compact design\u003c\/li\u003e \u003cli\u003elow dead volume\u003c\/li\u003e \u003cli\u003elong service life\u003c\/li\u003e \u003cli\u003eresistance to corrosion and wear\u003c\/li\u003e \u003c\/ul\u003e Our micro annular gear pumps are ideal for dosing and metering small amounts liquids. These pumps can handle a wide range of viscosities, flow rates, pressures, corrosive liquids, and even hazardous area certifications. The capability for liquid viscosity ranges from 0.3 to 1 million mPas. Dosing volumes start at 0.25 Âµl with flows ranging from 1 Âµl\/h to 1.1 l\/min. Pressure ranges from 0 to 150 bar (or higher) are possible. In addition, we even offer explosion-proof and magnetic hermetic options. \u003ch3\u003eWADose High Pressure Pumps\u003c\/h3\u003e \u003ca href=\"https:\/\/www.bronkhorst.com\/getmedia\/fcd8529b-5fb9-4fd3-acf5-cb12f9b83d2b\/Micro-dosing-pump-Wadose.png?width=\"\u003e\u003cimg class=\"size-medium alignright\" src=\"https:\/\/www.bronkhorst.com\/getmedia\/fcd8529b-5fb9-4fd3-acf5-cb12f9b83d2b\/Micro-dosing-pump-Wadose.png?width=\" alt=\"Bronkhorst-WADose-Pump-Liquid-Dosing-Low-Flow-Manufacturing-Instrumentation-PSC-Texas\" width=\"362\" height=\"374\"\u003e\u003c\/a\u003e WADose high pressure pumps are often combined with a \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis mass flow meter\u003c\/a\u003e for dosing purposes, such as dosing catalysts or liquefied gas dosing. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/precise-liquefied-gas-dosing\/\"\u003eLiquefied gas dosing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/precise-liquefied-gas-dosing\/\"\u003eDosing of pharmaceutical agents in liquid state\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGear Pumps for Liquid Dosing\u003c\/h3\u003e Gear pumps can be used in combination with our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis flow meters\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/es-flow-low-flow-ultrasonic-flow-meters-controllers\/\"\u003eUltrasonic volumetric flow meters\u003c\/a\u003e for various \u003ca href=\"https:\/\/psctexas.com\/tag\/dosing-pump\/\"\u003edosing applications\u003c\/a\u003e. \u003ch3\u003e\u003c\/h3\u003e Pumps are core components in a liquid dosing system. Dosing or metering pumps are able to measure the volume flow of a liquid. Process conditions like temperature, air containment, back pressure, and wear and tear influence the measured value. Therefore, the pump needs an additional device to make the required correction. \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eBronkhorst mass flow meters and volume flow meters\u003c\/a\u003eÂ offer the opportunity for direct steering of pumps to minimize the influence of the process conditions on accuracy and repeatability. And placing a flow meter inline with a pump gives the opportunity of pump steering by correcting the pump rotation frequency. Technically, this can be done by a flow meter and a PID controller. https:\/\/www.youtube.com\/watch?v=dDcBP5KXdSU \u003ch3\u003eFlow Meter with Integrated PID Controller\u003c\/h3\u003e We deliverÂ \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\/\"\u003eflow meters\u003c\/a\u003e with an integrated PID controller, thus avoiding the use of the filtered flow meter analog outputs and a separate PID controller. So, this \u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003ecombination of a pump and smart mass flow meter\u003c\/a\u003e offers direct mass flow control with high accuracy and repeatability, and is independent of process conditions. Additionally, this solution uses an unfiltered control signal, which also offers very high control speed and stability. \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow meters\u003c\/a\u003e can be combined with different kind of pumps as long as these can be controlled by a 0(4)-20 mA or 0-5(10) Vdc control signal. Also, we offer functional and system tests for a flow meter \/ pump system including fine-tuning. \u003ch3\u003eImproving Dosing Pump Processes with Flow Meters\u003c\/h3\u003e https:\/\/vimeo.com\/652784965 \u003ch3\u003eLiquid Dosing Applications with Pump and Flow Meter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/dosing-pump-control-for-improved-batching\/\"\u003eDosing Pump Control for Improved Batching\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\"\u003emRNA Vaccine Production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-can-you-improve-your-dosing-pump-performance-with-flow-meters\/\"\u003eDosing Pump in Laboratories and Pilot Plants\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/metering-pump-performance-improved-with-flow-meters\/\"\u003eImproving Metering Pump Performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-solution-for-hydrogen-storage\/\"\u003eHydrogen Storage on a Liquid Organic Hydrogen Carrier (LOHC)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003eCommon Flow Meter and Dosing Pump Combinations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/best-dye-dosing-systems\/\"\u003eHigh Precision Dye Dosing System\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=gkEEXey3RfQ","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878391734403,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/low-flow-liquid-dosing-pump-hnpm-tuthill-rotary-pumps-gear-pump-process-solutions-corp-texas.png?v=1763385925"},{"product_id":"gas-mixing-systems","title":"Gas Mixing Systems","description":"\u003cp\u003eFor many processes, very accurate compositions of gas are necessary, which means simply adding two or more gas streams together isn't sufficient. Homogeneous gas mixing systems enable operators to create accurate and \u003ca rel=\"noopener\" title=\"Gas Mixing Chambers for Homogeneous Gas Mixtures\" href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\" target=\"_blank\"\u003eprecise gas compositions\u003c\/a\u003e of two or more gases. Our gas mixers offer a repeatable and reliable process that helps eliminate discrepancies. They also ensure that operators have access to the exact gas compositions their processes require at any time. Mixing your own gas increases process efficiency and reduces the cost of having to purchase premixed gas cylinders.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecreate homogeneous gas mixtures from percentages down to ppm-ranges\u003c\/li\u003e\n\u003cli\u003ehigh accuracy and repeatability with a fast response\u003c\/li\u003e\n\u003cli\u003eflow ranges from 300 ml\u003csmall\u003en\u003c\/small\u003e\/min up to 10,000 ml\u003csmall\u003en\u003c\/small\u003e\/min\u003c\/li\u003e\n\u003cli\u003epressure rating up to 100 bar\u003c\/li\u003e\n\u003cli\u003eavailable with 1\/4\" or 6 mm connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHomogeneous Gas Mixing Systems\u003c\/h2\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas.jpg?v=1771512477\" alt=\"Bronkhorst-Homogeneous-Gas-Mixing-Chamber-Gas-Blending-Low-Flow-Calibration-Gas-Composition-Process-Solutions-Corp-PSC-Texas\" style=\"margin-left: 25px; float: right;\" width=\"501\" height=\"247\"\u003e\u003c\/div\u003e\n\u003cp\u003eUp to 12 \u003ca href=\"https:\/\/www.psctexas.shop\/products\/gas-cylinder-monitoring-system-gcm\" title=\"Gas Cylinder Monitoring System\"\u003egas cylinders\u003c\/a\u003e can connect to an equal amount of mass flow controllers. With accurate control, the gas flows enter a \u003ca href=\"https:\/\/www.psctexas.shop\/products\/gas-mixing-chamber\" title=\"Bronkhorst Gas Mixing Chamber\"\u003egas mixing chamber\u003c\/a\u003e where it becomes a homogeneous mixture. Then, it can flow directly to instrumentation, such as gas chromatographs. \u003ca href=\"https:\/\/www.iso.org\/standard\/45471.html\" rel=\"nofollow noopener\" title=\"ISO Standards\" target=\"_blank\"\u003eISO 6145-7:2009\u003c\/a\u003e describes a procedure to prepare calibration gas mixtures using commercially available \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/thermal-flow-meters\" title=\"Thermal Mass Flow Meters\"\u003ethermal mass flow\u003c\/a\u003e controllers. Calculation of the accuracy of the final gas composition that leaves the gas mixing system occurs through special software. The software considers the uncertainties in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\" title=\"Gas Flow Meters and Controllers\"\u003egas flows\u003c\/a\u003e and the gas composition of the initial gas cylinders.\u003c\/p\u003e\n\u003cp\u003eWhen comparing the purchase of gas cylinders with premixed gas mixtures, the preparation of gas mixtures on-site has some advantages. For example, the lifetime of premixed gas mixtures can be limited and expired gas can be costly. Furthermore, emergency gas deliveries and down-time due to not having necessary gas blends can be a huge problem. The costs for these gas cylinders can be quite high. And you can't always be sure that the concentration of the gas is still good, accurate, or that the mixture is still homogeneous. \u003c\/p\u003e\n\u003cp\u003eTherefore, it can be beneficial for users to prepare gas mixtures on their own with very low concentrations of specific compounds. As an operator, you'll no longer need to invest in cylinders of premixed gas cylinders. And it gives a lot of flexibility and freedom to calibrate an analyzer in your own time. Overall, our homogeneous gas mixing systems provide great value through high accuracy and flexibility as well as seamless, user-friendly controls, and powerful capabilities via \u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" title=\"Modbus Protocol\" target=\"_blank\"\u003eModbus\u003c\/a\u003e protocol.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHow to Create Custom Gas Mixtures\u003c\/h2\u003e\n\u003cp\u003eThere is more to creating gas mixtures than simply combining two gas streams into one. For example, if you need to dilute 1 ml\u003csmall\u003en\u003c\/small\u003e\/min of dopant with 10 l\u003csmall\u003en\u003c\/small\u003e\/min of dilution gas, you cannot expect to obtain a homogeneous mixture unless an appropriate mixing chamber is used. Luckily, our homogenous gas mixing systems offer precision in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\" title=\"Low Flow Instrumentation\"\u003elow flow\u003c\/a\u003e gas mixing applications.\u003c\/p\u003e\n\u003cp\u003eA user-friendly, touchscreen \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-control\" title=\"Automation Controllers\"\u003econtrols interface\u003c\/a\u003e allows users to easily input the composition of the desired gas mixture. Gas then automatically flows from gas cylinders and into a gas mixing chamber using gas flow meters and controllers. There, gas mixes homogeneously to quickly become ready for direct use in processes or it can undergo compression for later use. The process is both accurate and repeatable and users of any experience level can operate our gas mixing systems. With our system it's simple to blend your own high purity, homogenous gas streams on site.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Uses of a In-House Gas Mixing System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaboratory and Research Universities\n\u003cul\u003e\n\u003cli\u003emixing reference gas for analyzers\u003c\/li\u003e\n\u003cli\u003efor use in gas chromatography\u003c\/li\u003e\n\u003cli\u003egeneration of reference or calibration gases\u003c\/li\u003e\n\u003cli\u003eenvironmental testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and Beverage Production\n\u003cul\u003e\n\u003cli\u003efermentation of beer\u003c\/li\u003e\n\u003cli\u003ebioreactor applications for oxygen and CO\u003csmall\u003e2\u003c\/small\u003e control\u003c\/li\u003e\n\u003cli\u003ecell culture incubation\u003c\/li\u003e\n\u003cli\u003euse in sterile production environments\u003c\/li\u003e\n\u003cli\u003eextending shelf-life and freshness preservation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSemiconductor and Electronics Manufacturing\n\u003cul\u003e\n\u003cli\u003eplasma etching\u003c\/li\u003e\n\u003cli\u003eoxidation\u003c\/li\u003e\n\u003cli\u003edoping processes\u003c\/li\u003e\n\u003cli\u003echemical vapor deposition (CVD) processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOil and Energy\n\u003cul\u003e\n\u003cli\u003enatural gas blending\u003c\/li\u003e\n\u003cli\u003eflare gas simulation\u003c\/li\u003e\n\u003cli\u003eprocess optimization \u003c\/li\u003e\n\u003cli\u003esafety systems testing\u003c\/li\u003e\n\u003cli\u003ehydrogen blending research\u003c\/li\u003e\n\u003cli\u003efuel cell testing\u003c\/li\u003e\n\u003cli\u003epower generation combustion control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAerospace, Aviation, and Automobiles\n\u003cul\u003e\n\u003cli\u003eemissions testing\u003c\/li\u003e\n\u003cli\u003eengine combustion research\u003c\/li\u003e\n\u003cli\u003eenvironmental simulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878400680067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Homogenous-Gas-Mixing-Systems-Bronkhorst-Low-Flow-Meters-Gas-Mixing-Chamber-Reference-Gas-Generation-Calibration-Gas-Chromatography-Bioreactor-Oxidation-Control-Process-Solutions-Corp.png?v=1771519548"},{"product_id":"turbine-flow-meter-tm0100","title":"Turbine Flow Meter - TM0100","description":"\u003cp\u003eOur liquid turbine flow meters come in a comprehensive variety of offerings, accuracy, and impressive temperature operating ranges. All of our in-line meter series (installed within a length of pipe) and the wafer-style turbine meters (typically inserted between two flanges) are precision machined stainless steel. They are also available in a wide variety of materials of construction.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"product_title\"\u003eTM Series – Liquid Inline Turbine Flow Meters\u003c\/h2\u003e\n\u003cdiv class=\"product_desc\"\u003eThe TM Series Liquid Inline Flow Meter is a highly­ versatile product line that offers all stainless steel, precision-machine components with CD4MCu and\/or 416 stainless steel rotors. These flow meters are ideal for liquid applications and are available with a variety of process connections, including threaded, flanged, and Victaulic. This series provides ±1.0% standard linearity and is repeatable to ±0.10% over the entire flow range. These turbine flow meters have a unique K-factor that is NIST-traceable to factory or independent laboratory calibration.\n\u003cul\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eAccuracy Over Range: ±1.0% (model TM0038 ±2.0%)\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eOperating Temperature: -100 to 800˚F\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eLine Sizes: from 3\/8 inch through 10 inches\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eRepeatability Over Flow Range: ±0.10%\u003c\/li\u003e\n\u003cli\u003eLine Sizes: from 3\/8″ to 10″\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eCertifications: ISO9001, AS9100, 3A, NIST, NTEP, CTEP, OIML R81\/R117\/MID, CSA, Intrinsic Safety and Canadian CRN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Turbines, Inc.","offers":[{"title":"Default Title","offer_id":46584279826563,"sku":"TM0100","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Turbine-Flow-Meter-Turbines-Inc-TM-Series-In-Line-Liquid-Flow-Meters-Process-Solutions.png?v=1763386402"},{"product_id":"classic-810-threaded-thermal-flow-sensor","title":"CLASSIC 810 Threaded Thermal Flow Sensor","description":"The Kayden CLASSIC 810 thermal flow, level, and interface switch and transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, it is available in a wide range of thread sizes and insertion lengths. All models also feature a rugged flameproof enclosure with blind or lens cover options. The CLASSIC 810, from \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e, has advanced digital electronics that will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA Analog Output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 810 Thermal Flow Meter, Level Switch, Interface Measurement\u003c\/h3\u003e \u003ch5 style=\"text-align: left;\"\u003eProcess Connections - MNPT\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1\/2 inches\u003c\/li\u003e \u003cli\u003e3\/4 inches\u003c\/li\u003e \u003cli\u003e1.0 inches\u003c\/li\u003e \u003cli\u003e1 1\/4 inches\u003c\/li\u003e \u003cli\u003e1 1\/2 inches\u003c\/li\u003e \u003cli\u003e2 inches\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1.2 inches (3.0 cm)\u003c\/li\u003e \u003cli\u003e2 inches (5.0 cm)\u003c\/li\u003e \u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e \u003cli\u003e4 inches (10.1 cm)\u003c\/li\u003e \u003cli\u003e6 inches (15.2 cm)\u003c\/li\u003e \u003cli\u003e9 inches (22.8 cm)\u003c\/li\u003e \u003cli\u003e12 inches (30.4 cm)\u003c\/li\u003e \u003cli\u003e18 inches (45.7 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available from 2.5 inches (6.0 cm) to 120 inches (305 cm) by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 810\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 Vdc\u003c\/li\u003e \u003cli\u003e120-240 Vac\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eCSA \u0026amp; FM: 3480 psi, 24000 kPa, 240 bar\u003c\/li\u003e \u003cli\u003eCRN (316\/316L Stainless Steel) - Canadian Registration\u003c\/li\u003e \u003cli\u003eNumber 0F22124.2C: 1990 psi, 13721 kPa, 137.2 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for Kayden CLASSIC 810 Thermal Flow, Level, Interface\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003ehigh pressure thermal flow meter\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eThermal Flow Meter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel Switch and Detection\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface Measurement\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421454979,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-810-Threaded-Flow-Meter-Level-Switch-Interface-Temperature-Thermal-Sensor-Process-Solutions-Corp.png?v=1763386416"},{"product_id":"classic-812-flow-level-switch-flanged","title":"CLASSIC 812 Flow, Level Switch (Flanged)","description":"The CLASSIC 812 Flow, Level Switch and Transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the CLASSIC 812 is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings, and insertion lengths. All \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 812 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eper flange rating, ASME B16.5\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eother materials available\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the CLASSIC 812\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, level switch \u0026amp; interface\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421487747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-812-Flanged-Switch-and-Transmitter-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-PSC-Texas.png?v=1763386417"},{"product_id":"classic-814-flanged-retractable-packing-gland","title":"CLASSIC 814, Flanged Retractable Packing Gland","description":"The CLASSIC 814 Flow, Level, and Interface Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 814 Retractable Packing Gland is available with a Raised Face or RTJ Flange, in a wide range of flange sizes and ANSI ratings, with low and medium pressure applications. All Kayden models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23827 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\" alt=\"Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas\" width=\"1000\" height=\"380\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eretractable packing gland\u003c\/li\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edependent on flange rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-40 to 320ËF (-40 to 160ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind c0ver or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 814 Flanged, Retractable Packing Gland\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 814 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421520515,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-switch-interface-sensing-process-solutions-texas.png?v=1763386418"},{"product_id":"classic-816-threaded-retractable-packing-gland","title":"CLASSIC 816, Threaded Retractable Packing Gland","description":"The CLASSIC 816 Flow, Interface, and Level Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the CLASSIC 816 Threaded Retractable Packing Gland is available in a wide range of insertion lengths, with low and medium pressure applications. All \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23832 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp.jpg\" alt=\"Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Corp\" width=\"1000\" height=\"395\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 816 Flow, Interface, Level Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections - MNPT\u003c\/h5\u003e \u003cul\u003e \u003cli\u003ethreaded retractable packing gland (1\" MNPT)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the Kayden CLASSIC 816 Interface, Flow, and Level Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edetermined by retractable packing gland rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-40 to 320ËF (-40 to 160ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 816 Interface, Flow, and Level Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 816 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421553283,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Texas.png?v=1763386419"},{"product_id":"classic-830-threaded-in-line-flow-level","title":"CLASSIC 830, Threaded In-Line Flow, Level","description":"The CLASSIC 830 Threaded, In-Line Flow Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes and is available with 3\/4\" FNPT connections in a horizontal or vertical orientation. In addition, all \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 830 Threaded In-Line Flow Transmitter and Switch\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3\/4\" FNPT\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 20,000 cc\/second\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Assembly Body Length\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3.5 inches (8.8 cm)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Mounting Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003ehorizontal\u003c\/li\u003e \u003cli\u003evertical\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput Power for the Kayden CLASSIC 830 In-Line Flow Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3,480 psi\u003c\/li\u003e \u003cli\u003e24,000 kPa\u003c\/li\u003e \u003cli\u003e240 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPTÂ conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e with nickel braze\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 830 for In-Line Flow Measurement and Control\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-In-Line-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 830 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421586051,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-830-Threaded-In-Line-Flow-Meter-level-switch-interface-senor-process-solutions-corp.png?v=1763386420"},{"product_id":"classic-832-flanged-in-line-flow-switch","title":"CLASSIC 832, Flanged In-Line Flow Switch","description":"The CLASSIC 832 Flanged, In-Line Flow Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes and is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings and assembly widths. In addition, all \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 832 Flanged In-Line Flow Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 20,000 cc\/second\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Assembly Body Width\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 7 inches (18 cm) to maximum 72 inches (182 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003cli\u003eminimum width varies with flange size and rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput Power for the Kayden CLASSIC 832 In-Line Flow Transmitter and Switch\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e3,480 psi\u003c\/li\u003e \u003cli\u003e24,000 kPa\u003c\/li\u003e \u003cli\u003e240 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e with nickel braze\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 832 Flow Switch for In-Line Flow Control andÂ Measurement\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eFM\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-In-Line-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Flow-Switch-Pipeline-Gas-Processing-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflow switch for pump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 832 Flow Switch and Level Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421618819,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-832-Flanged-In-Line-Flow-Switch-Level-gas-processing-Transmitter-Interface-Media-Process-Solutions-Corp.png?v=1763386421"},{"product_id":"master-touch-series-8600-8700mpnh-gen-inline-flow-meters","title":"Master-Touch Series 8600-8700MPNH GEN Inline Flow Meters","description":"\u003cp\u003eMaster-Touch Series 8600-8700MPNH GEN Inline Flow Meters are rugged, cleanable, thermal mass flow sensors. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors feature construction of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then receive a thin glass coating.\u003c\/p\u003e\n\u003cp\u003eThe assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit.\u003c\/p\u003e\n\u003cp\u003eThe second sensor undergoes self-heating, using a temperature sensor and bridge circuitry, to a constant temperature above that of the gas stream. The bridge maintains overheat temperature and counterbalances the temperature effects through Eldridge Product Inc.'s (EPI) proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ±  50% of factory calibration pressure\u003c\/li\u003e\n\u003cli\u003ecertifications: CE, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\" title=\"CSA Group\"\u003eCSA\/CUS\u003c\/a\u003e - Class 2252-03 \u0026amp; 2252-83, CSA Enclosures Type 4X, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP66\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eMaster-Touch 8600-8700 Series Flow Meters\u003c\/h2\u003e\n\u003cp\u003eMaster-Touch inline style thermal mass flow meters include a flow section that matches the user’s flow conduit and then plumbs directly into the process line. The sensing elements mount directly in the flow section for exposure to the process gas. The inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 4\" pipe or tube. They feature a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as per application requirement.\u003c\/p\u003e\n\u003cp\u003ePipe sizes more than 4\" typically require insertion style thermal mass flow meters. Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers ratings for non-hazardous environments. Furthermore, the enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eThermal Mass Flow Meters for Gases\u003c\/h2\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-match, reference-grade platinum Resistance Temperature Detectors (RTDs). In addition, the platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and are insensitive to pressure changes, so the output signal is a true mass flow rate signal.  \u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878425944195,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Eldridge-Products-Master-Touch-Series-8600-8700MPNH-GEN-Inline-Aeration-Flow-Meters-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.png?v=1763386473"},{"product_id":"insertion-flow-meters-master-touch-series-8800mp-haz","title":"Insertion Flow Meters, Master-Touch Series 8800MP HAZ","description":"Our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003einsertion flow meters\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI\u003c\/a\u003e, provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter is calibrated using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± (1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eThermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eMaster-Touch Series 8800MP HAZ Insertion Flow Meters\u003c\/a\u003e include a rugged and cleanable thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. This maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream from control by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003eMaster-Touch 8800 Series Insertion Flow Meters for Hazardous Locations\u003c\/h3\u003e Insertion style thermal mass flow meters include a sensor and probe assembly that is inserted into the process gas flow conduit to allow the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. The tube length must be specified upon ordering. For other probe diameters and lengths, please consult the factory. Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/inline-flow-meters\/\"\u003einline flow section\u003c\/a\u003e or to the \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003einsertion probe assembly\u003c\/a\u003e at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display\/keypad assembly. \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eThermal Mass Flow Insertion Flow Meters\u003c\/a\u003e Operation Principle\u003c\/h3\u003e Thermal mass insertion flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matching, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller uses smart sensor technology to preferentially heat one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase relates directly to the gas molecular rate of flow. Our sensors are also temperature compensated for a wide process gas temperature range. In addition, they are insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8800 MP HAZ\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/11\/EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26268 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/11\/EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas.jpg\" alt=\"EPI-Master-Touch-8800MP-HAZ-Insertion-Flow-Meters-for-Hazardous-Areas-Eldridge-Products-Inc-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch5\u003eCertifications\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eKOSHA\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eT2\u003c\/li\u003e \u003cli\u003eT3\u003c\/li\u003e \u003cli\u003eT4\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eProbe Selection\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 1\/2\", 3\/4\", 1\"\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6 to 60\" (depending on width)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878425976963,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Master-Touch-Series-8800-MP-HAZ-Insertion-Flow-Meter-for-Hazardous-Areas-EPI-Eldridge-Products-Inc-Process-Solutions-Corp.png?v=1763386473"},{"product_id":"master-touch-8200mp-haz-r-remote-transmitter-insertion","title":"Master-Touch 8200MP HAZ R, Remote Transmitter, Insertion","description":"The Master-Touch 8200MP HAZ R Series includes a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor with remote transmitter\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built upon the ceramic substrate and they receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream. The temperature sensor and bridge circuitry controls the heating process. Our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003e8200 Series Flow Meters with Remote Transmitter for Hazardous Locations\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eInsertion style thermal mass flow meters\u003c\/a\u003e include a sensor and probe assembly that inserts into the process gas flow conduit. Â In doing this, it allows process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. Operators must indicate the tube length upon ordering. For other probe diameters and lengths, \u003ca href=\"mailto:sales@psctexas.com\"\u003eplease reach out for additional support\u003c\/a\u003e. Remote style thermal mass flow meters utilize two enclosures. First, an enclosure mounts at the point of measurement on the probe assembly. This enclosure offers ratings for hazardous environments. The second (remote) enclosure positions in a readily accessible location with non-hazardous conditions. \u003ca href=\"mailto:sales@psctexas.com\"\u003eContact us for information concerning remote explosion-proof enclosure\u003c\/a\u003e. The remote enclosure includes all the electrical connections as well as the linearizing electronics and the display\/keypad assembly. A 5-conductor shield cable is necessary to carry the flow signal between the two enclosures. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003eThermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003eThermal mass flow meters\u003c\/a\u003e use the principle of convective heat transfer to directly measure mass flow. \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPIâs\u003c\/a\u003e proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors temperature compensate for a wide process gas temperature range and are insensitive to pressure changes. Thus, the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch 8200MP HAZ R, Remote Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26291 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Master-Touch-8200MP-HAZ-R-Insertion-Flow-Meter-with-Remote-Transmitter-Process-Solutions-Texas\" width=\"1000\" height=\"502\"\u003e\u003c\/a\u003e \u003ch5\u003eCertifications\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eKOSHA\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eT2\u003c\/li\u003e \u003cli\u003eT3\u003c\/li\u003e \u003cli\u003eT4\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eDual Sided Explosion-Proof Enclosure For Hazardous Locations\u003c\/li\u003e \u003cli\u003e8\" X 10\" Ordinary Locations (Non-Explosion Proof)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eProbe Selection\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 1\/2\", 3\/4\", 1\"\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6 to 60\" (depending on width)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBall Valve Retractor\u003c\/strong\u003e: Optional\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426009731,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-Series-8200MP-HAZ-R-Remote-Insertion-Flow-Meters-Process-Solutions-Corp.png?v=1763386474"},{"product_id":"master-touch-averaging-flow-tube-9700mp-haz-fat","title":"Master-Touch Averaging Flow Tube, 9700MP HAZ FAT","description":"\u003cp\u003eMaster-Touch 9700MP HAZ FAT in-line averaging flow tube flow meters include a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors, from Eldridge Products Inc. (EPI), consist of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating.\u003c\/p\u003e\n\u003cp\u003eThe assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The flow tube sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas.\u003c\/p\u003e\n\u003cp\u003e This maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream from control by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e9700 MP Series Averaging Flow Tube Flow Meter for Hazardous Areas\u003c\/h2\u003e\n\u003cp\u003eInline style thermal mass flow meters include a flow section that meets the user’s flow conduit. Then it plumbs directly into the process line. The sensing elements of this design mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 4\" pipe or tube. Furthermore, they feature a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc.\u003c\/p\u003e\n\u003cp\u003ePipe sizes more than 4\" typically require insertion style thermal mass flow meters. Integral style flow tube thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure offers ratings for hazardous environments. The enclosure mounts directly to the inline flow section at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003eOur patented Flow Averaging Tube (FAT) designs use the principle of convective heat transfer to directly measure mass flow. Moreover, they are ideal for most applications with limited available straight run. In many installations, the up-stream straight run can reduce to three diameters. The probe has several large diameter inlet ports along the length of the upstream impact surface.\u003c\/p\u003e\n\u003cp\u003eThe pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas returns to the main flow stream through the ports near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still require some minor adjustment to achieve the best accuracy.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 9700 MP HAZ FAT\u003c\/h2\u003e\n\u003ch4\u003eCertifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iecex.com\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApprovals\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeter Orientation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: horizontal, vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: left side, right side, above pipe, below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeter Housing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426042499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-Series-9700MP-HAZ-FAT-Inline-Flow-Tube-Flowmeter-Process-Solutions-Texas.png?v=1763386475"},{"product_id":"inline-flow-switch-epi-series-7000","title":"Inline Flow Switch, EPI Series 7000","description":"The enclosure for the Series 7000 \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow switch\u003c\/a\u003e offers a rating for use in hazardous locations with T2, T3, and T4 approvals and it is available in domestic and international markets. The diecast aluminum, \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Type 4X\u003c\/a\u003e watertight enclosure is both flame and explosion proof and features a corrosion resistant finish. \u003cul\u003e \u003cli\u003eapprovals: \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eUL\/CUL Class I, Division 1, Group B\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Types 4X\/7\/9\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX approval options\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003efinish: safety blue polyester powder-coat\u003c\/li\u003e \u003c\/ul\u003e The 7000 series flow switch includes a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The second sensor undergoes self-heating to a constant temperature above that of the gas stream. The temperature sensor and bridge circuitry controls the heating process. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26308 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.jpg\" alt=\"EPI-Eldridge-Products-Inc-7000-Inline-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas\" width=\"1000\" height=\"502\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3 style=\"text-align: left;\"\u003eEPI 7000 Series Inline Flow Switch\u003c\/h3\u003e The inline style thermal mass flow switch includes the flow sensing element, temperature sensing element, bridge amplifier\/signal output board, transmitter encloÂ­sure, and flow section. The flow section matches the userâs flow conduit and plumbs directly in the flow line. The sensing elements mount directly in the flow section for exposure to the process flow. Inline flow switches are available in sizes from 1\/4\" pipe through 4\" pipe and offer threaded male NPT ends as the standard mounting style. Optional end mounting styles are available, such as tube ends, tube end fittings, butt weld ends, flanged end configurations, etc. Pipe sizes more than 4\" typically require insertion style thermal mass flow switches. All of EPIâs flow switches have two single-pole, double-throw relays for Hi\/Hi, Lo\/Lo, and Hi\/Lo capability. The contact closure is 5 amps @ 24 VDC and 115 VAC. Two LEDs provide verification when the Hi or Lo alarm triggers. The standard configuration has 316 Stainless Steel wetted parts (Hastelloy \u0026amp; Monel are also available). This design provides a rugged, cleanable instrument that's suitable for use in applications where corrosion, abrasion, high pressure, or rough handling may occur. \u003ch3 style=\"text-align: left;\"\u003eThermal Mass Flow Switches Operating Principle\u003c\/h3\u003e Thermal mass flow switches use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is within a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Smart sensor technology operates the microcontroller which preferentially heats one RTD. Then, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, thus causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors also offer temperature compensation for a wide process gas temperature range. They are also insensitive to pressure changes, so the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426075267,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Eldridge-Products-Inc-7000-Inline-Mass-Flow-Switch-Gen-Flow-Meter-Switch-PSC-Texas.png?v=1763386476"},{"product_id":"valumass-series-400-val-inline-flow-meters","title":"ValuMass Series 400 VAL Inline Flow Meters","description":"The ValuMass Series 400 VAL \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/inline-flow-meters\/\"\u003einline flow meters\u003c\/a\u003e are rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensors\u003c\/a\u003e. Our VALGEN-RD flow meters consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors position upon a ceramic substrate and then they receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3 style=\"text-align: left;\"\u003eMunicipal and Industrial Inline Flow Meters with Thermal Mass Flow Sensors\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26318 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas.jpg\" alt=\"EPI-ValuMass-400-Series-Inline-Flow-Meters-VALGEN-RB-Thermal-Mass-Flow-Meter-Process-Solutions-Texas\" width=\"1000\" height=\"500\"\u003e\u003c\/a\u003e Our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow meters\u003c\/a\u003e provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter is also calibrated using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eValuMass Series 400 VAL Inline Flow Meters\u003c\/h3\u003e These thermal mass flow inline flow meters include a flow section that matches the userâs flow conduit. It then plumbs directly into the process line. The sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2\" pipe. The 3.5\" long flow sections also have MNPT ends as standard for easy mounting in the process line. \u003ca href=\"mailto:sales@psctexas.com\"\u003eYou can contact us\u003c\/a\u003e to inquire about pipe sizes over 2\". Integral style thermal mass inline flow meters contain all the electrical components and connections within one enclosure. Furthermore, this enclosure offers a rating for hazardous environments. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display assembly. Each VAL Series 400 aluminum enclosure includes a powder-coat-painted die-cast base and lid with a seal. The ratings available for the enclosure are: \u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP66, NEMA 1, 2, 4, 4X\u003c\/a\u003e. \u003ch3 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI Thermal Mass Flow Meters\u003c\/a\u003e\u003c\/h3\u003e Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPIâs\u003c\/a\u003e proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference. First, the process gas flow dissipates heat from the first RTD. This causes an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature also compensated for a wide process gas temperature range and insensitive to pressure changes. Therefore, the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426108035,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-ValuMass-400-Series-Inline-Flow-Meter-VALGEN-RB-Thermal-Mass-Flow-Meters-Process-Solutions-Corp.png?v=1763386477"},{"product_id":"valumass-series-540-val-insertion-flow-meters","title":"ValuMass Series 540 VAL Insertion Flow Meters","description":"\u003cp\u003eThe ValuMass Series 540 is a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are upon a ceramic substrate and then receive a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance.\u003c\/p\u003e\n\u003cp\u003eThe sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. It also maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge force the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eRugged Flow Meters for Gases\u003c\/h4\u003e\n\u003cp\u003e Our ValuMass flow meters, from Eldridge Products Inc. (EPI), provide accurate, consistent, and rapid real-time flow measurement. Furthermore, the sensor is both temperature and pressure corrective. Each flow meter also undergoes calibration using standards traceable to the National Institute of Standards and Technology (\u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" title=\"National Institute of Standards and Technology\" rel=\"noopener\"\u003eNIST\u003c\/a\u003e).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eValuMass 540 Series Flow Meters\u003c\/h2\u003e\n\u003cp\u003eInsertion style thermal mass flow meters include a sensor \u0026amp; probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\" OD probes in 6\" to 36\" lengths as well as 3\/4\" probes to 60\" lengths. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options.\u003c\/p\u003e\n\u003cp\u003eUsers must specify the tube length upon ordering. Integral style ValuMass thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure also offers a rating for non-hazardous environments. The enclosure mounts directly to the insertion probe assembly at the point of measurement. It includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eEPI Thermal Mass Flow Meters\u003c\/h2\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then the other RTD acts as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD. This causes an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are also temperature compensated for a wide process gas temperature range. This makes them insensitive to pressure changes, so the output signal is a true mass flow rate signal.\u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426140803,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/ValuMass-Series-540-VAL-Eldridge-Products-Inc-EPI-Thermal-Mass-Flow-Meter-Insertion-Flow-Meter-Process-Solutions-Texas.png?v=1763386478"},{"product_id":"master-touch-series-8200mpnh-gen-remote-insertion-flow-meter","title":"Master-Touch Series 8200MPNH GEN Remote Insertion Flow Meter","description":"Master-Touch \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow meters\u003c\/a\u003eÂ provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eaccuracy: Â± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e \u003cli\u003erepeatability: Â± 0.2% of full scale\u003c\/li\u003e \u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003egas pressure effect: negligible over Â± 50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/\"\u003eFlow Meters for Industrial Flow Measurement and Municipal Flow Metering\u003c\/a\u003e\u003c\/h3\u003e The Master-Touch 8200MPNH Gen Series, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEPI\u003c\/a\u003e, includes rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensors\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly then slips into a stainless-steel sheath for corrosion and abrasion resistance. Master-Touch GEN Series thermal mass flow meter enclosures offer ratings for use in ordinary locations. Furthermore, they are applicable in wet and dusty environments and are corrosion resistant. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26337 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.jpg\" alt=\"EPI-Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp\" width=\"1000\" height=\"500\"\u003e\u003c\/a\u003e \u003cul\u003e \u003cli\u003etransparent cover with four non-metallic corner screws\u003c\/li\u003e \u003cli\u003emaintenance free as well as corrosion resistant\u003c\/li\u003e \u003cli\u003eknockouts in the base facilitate conduit entry\u003c\/li\u003e \u003cli\u003econtinuous gaskets made of polyurethane foam guarantee optimal integrity\u003c\/li\u003e \u003c\/ul\u003e The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas. This maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques. \u003ch3 style=\"text-align: left;\"\u003eMaster-Touch 8200 Series Flow Meters for Non-hazardous Use\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow-2\/insertion-flow-meters\/\"\u003eInsertion style thermal mass flow meters\u003c\/a\u003e include a sensor \u0026amp; probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow sensing elements. Our insertion style flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. Users must specify the tube length upon ordering. \u003ca href=\"mailto:sales@psctexas.com\"\u003ePlease contact us\u003c\/a\u003e for other probe diameters and lengths. Master-Touch remote style thermal mass flow meters utilize two enclosures. One enclosure mounts at the point of measurement on the flow section. This enclosure also offers a rating for non-hazardous environments. Then, the second (remote) enclosure is usually in a readily accessible location with rating for non-hazardous conditions. The remote enclosure includes all the electrical connections as well as the linearizing electronics. Furthermore, it features the display \/ keypad assembly. A 5-conductor shielded cable is necessary to carry the flow signal between the two enclosures. \u003ch3\u003eMaster-Touch Rugged Thermal Mass Flow Meters\u003c\/h3\u003e Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometric, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is in a 316 Stainless Steel sheath or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Then, the other RTD acts as the temperature reference. As a result, the process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range. They are insensitive to pressure changes, so the output signal is a true mass flow rate signal.","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878426206339,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Master-Touch-Series-8200MPNH-GEN-R-Remote-Flow-Transmitter-Thermal-Mass-Flow-Meter-Insertion-Probe-Process-Solutions-Corp.png?v=1763386480"},{"product_id":"industrial-wireless-monitoring-systems","title":"Industrial Wireless Monitoring Systems","description":"\u003cp\u003eWe specialize in providing critical asset and process monitoring solutions to industrial facilities and industrial automation systems through the use of wireless cloud computing technology. Our engineers can seamlessly integrate independent processes to communicate directly with your DCS, even in the most remote locations. As a result, our industrial wireless monitoring systems increase operational safety, ensure environmental compliance, and improve productivity and efficiency by reducing downtime.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003enear real-time view of any asset, equipment, or automation process\u003c\/li\u003e\n\u003cli\u003eeasy to retrofit with existing equipment and \u003ca title=\"Sensors for Industrial Automation\" href=\"https:\/\/www.psctexas.shop\/collections\/sensors\"\u003esensors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ebring all operations data back to control room, DCS, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC\u003c\/a\u003e, etc.\u003c\/li\u003e\n\u003cli\u003eoptional, easy to use cloud-based portal with trending data, predictive analysis, as well as custom programmed functions to suit your specific needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eEasy to Implement Wireless Monitoring Systems to Optimize Process Automation\u003c\/h2\u003e\n\u003cp\u003eFurthermore, with our cloud software and remote monitoring transmitters, users can view real trends of data from any device, anywhere in the world. Our wireless monitoring systems are suitable for any application and be customized to fit your exact needs while providing custom online portals to bring all your data to the cloud in a way that makes sense for you.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eloop-powered or solar options with battery back-up for remote data points\u003c\/li\u003e\n\u003cli\u003ecustomizable alarm options, password protection, and industry-leading security\u003c\/li\u003e\n\u003cli\u003escalable: from transmission of one single data point to the engineering and installation of an entirely new automation system\u003c\/li\u003e\n\u003cli\u003elow-cost: save money by not running copper wires, save money compared to big name brands, save money by effectively prioritizing and managing maintenance plans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eMake Any Data Point Go Wireless\u003c\/h2\u003e\n\u003cp\u003eOur industrial remote monitoring systems are designed and assembled in-house here in Houston, Texas in our \u003ca href=\"https:\/\/psctexas.com\/iso-certification\" title=\"ISO Certification for Process Solutions Corp.\" target=\"_blank\"\u003eISO certified workshop\u003c\/a\u003e. We offer multiple certifications and approvals, thus ensuring quality and safety for most any application. We supply a wide range of \u003ca title=\"Industrial Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/sensors\"\u003eindustrial instrumentation\u003c\/a\u003e and provide engineering support to build entire \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/packaged-solutions\" title=\"Packaged Solutions from Process Solutions Corp.\"\u003eautomation systems\u003c\/a\u003e with remote control and real-time process monitoring. Our industrial wireless monitoring solutions are flexible and we can retrofit them into any application, meaning you can also save money by using your existing sensors and instrumentation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"Industrial Pressure Transducers\" href=\"https:\/\/www.psctexas.shop\/collections\/pressure-transducers\"\u003epressure transducers\u003c\/a\u003e, \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitters\u003c\/a\u003e, \u003ca title=\"Level Sensors\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel transmitters and switches\u003c\/a\u003e, \u003ca title=\"Flow Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/flow-instrumentation\"\u003eflow meters and controllers\u003c\/a\u003e, vibration, \u003ca title=\"Position Sensors\" href=\"https:\/\/www.psctexas.shop\/collections\/position-sensors\"\u003eLVDT position sensors\u003c\/a\u003e, and more\u003c\/li\u003e\n\u003cli\u003eGPS tracking\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Industrial Gas Detectors\" href=\"https:\/\/www.psctexas.shop\/collections\/industrial-gas-detectors\"\u003egas detection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003ebrake and tire temperature and pressure monitoring\u003c\/li\u003e\n\u003cli\u003ecameras with recording capabilities\u003c\/li\u003e\n\u003cli\u003eany sensor necessary for your application\u003c\/li\u003e\n\u003cli\u003ecommunication via various Ethernet protocols, \u003ca href=\"https:\/\/www.psctexas.shop\/products\/mqtt-sparkplug-for-mqtt-protocol\" title=\"MQTT Sparkplug\"\u003eMQTT\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/iot-sim-plans\/\" title=\"IoT SIM Plans from Process Solutions Corp.\" target=\"_blank\"\u003ecellular\u003c\/a\u003e, \u003ca href=\"https:\/\/lora-alliance.org\/\" title=\"LoRa Alliance\" rel=\"noopener\" target=\"_blank\"\u003eLoRaWAN\u003c\/a\u003e, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eRemote Monitoring of Industrial Process via Cloud Software\u003c\/h2\u003e\n\u003cp\u003eWith our intelligent process insight, operators gain an unprecedented look into their industrial processes. Going beyond the basics, your data can also integrate into our sophisticated Cloud Computing software. We develop our software in-house and can provide a completely custom program that brings all your data to one place and presents it in a way that is actually useful and meaningful.\u003c\/p\u003e\n\u003cp\u003eOur Cloud Solutions give you smart insight into your processes as well as asset performance. This will help you make informed decisions to increase safety and prioritize maintenance in addition to de-bottlenecking processes and much more. We provide insight on near real-time data for numerous data points for example, temperature, pressure, vibration, level, gas detection, and much more.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eApplications that Benefit from Industrial Wireless Monitoring Systems\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003erotating equipment vibration monitoring\u003c\/li\u003e\n\u003cli\u003etemperature and pressure profiling\u003c\/li\u003e\n\u003cli\u003epipelines and transportation\u003c\/li\u003e\n\u003cli\u003epower plants as well as nuclear energy\u003c\/li\u003e\n\u003cli\u003eremote monitoring of tanks, for example: CNG, nitrogen, hydrogen, etc.\u003c\/li\u003e\n\u003cli\u003efans and pumps equipment health\u003c\/li\u003e\n\u003cli\u003emaintenance predictions and prioritization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eExamples of Current Industrial Wireless Monitoring Systems\u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003eGas Cylinder Monitoring System\u003c\/h4\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Map-gas-cylinder-tracking-GPS-location-gas-asset-monitoring-bottles-PSC-Texas_480x480.jpg?v=1771015888\" alt=\"Map-gas-cylinder-tracking-GPS-location-gas-asset-monitoring-bottles-PSC-Texas\" style=\"margin-left: 025px; float: right;\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.psctexas.shop\/products\/gas-cylinder-monitoring-system-gcm\" title=\"Gas Cylinder Monitoring System\" rel=\"noopener\" target=\"_blank\"\u003eGas Cylinder Monitoring System (GCM)\u003c\/a\u003e is an innovative solution that enhances the safety, efficiency, and compliance of gas storage and usage across various industries. Our GCMs allow users to seamlessly view and track important gas cylinder data such as gas type, blend, composition, expiration dates, lot numbers, etc., in addition to optional real time pressure monitoring to know the exact supply on hand – all of which is accessible for viewing on the web or app via a cloud server.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003elive tracking of gas assets via optional QR scanning system: gas blend \/ type \/ composition, expiration and installation dates, lot numbers, and more\u003c\/li\u003e\n\u003cli\u003eaccess documentation through password protected, cloud web portal from phone or computer\u003c\/li\u003e\n\u003cli\u003eethernet enabled with access to \u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" title=\"Modbus Protocol\" target=\"_blank\"\u003eModbus\u003c\/a\u003e and other protocols\u003c\/li\u003e\n\u003cli\u003eefficient management of certificates of analysis and other documentation\u003c\/li\u003e\n\u003cli\u003eenhance environmental and safety compliance with automated record keeping\u003c\/li\u003e\n\u003cli\u003ereduce operational costs and human error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTanker Truck Fleet Monitoring\u003c\/h4\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/tanker-truck-tracking-remote-monitoring-system-tire-pressure-brake-temperature-gps-location-tank-fill-level-process-solutions-corp-psc-texas.jpg?v=1771428528\" alt=\"tanker-truck-tracking-remote-monitoring-system-tire-pressure-brake-temperature-gps-location-tank-fill-level-process-solutions-corp-psc-texas\" style=\"margin-bottom: 16px; margin-left: 25px; float: right;\" width=\"500\" height=\"312\"\u003e\u003c\/div\u003e\n\u003cp\u003eOur Tanker Truck Fleet Monitoring Systems are ideal for live monitoring to reduce breakdowns, prioritize preventative maintenance, increase safety, and verify custody transfer metrics. These all-in-one packages can transmit any desired data point to a local display. In addition, data can upload directly via \u003ca rel=\"noopener\" title=\"IoT SIM Plans\" href=\"https:\/\/psctexas.com\/iot-sim-plans\/\" target=\"_blank\"\u003ecellular data\u003c\/a\u003e to a custom cloud-based portal hosted on our highly secure server or host it on your own internal network. Accessible from anywhere around the globe, operators and management can monitor tanker trucks in real-time to protect critical assets.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003elive fleet monitoring via GPS tracking\u003c\/li\u003e\n\u003cli\u003edual SIM capabilities for remote areas\u003c\/li\u003e\n\u003cli\u003emonitor: brake temperature, tire pressure, tire temperature, tank fill, cameras and screenshots to verify fill level, or any custom metric upon request\u003c\/li\u003e\n\u003cli\u003ebattery backup and solar charging\u003c\/li\u003e\n\u003cli\u003eon-board display and system settings controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eGas Plant Remote Monitoring\u003c\/h4\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg style=\"margin-left: 25px; float: right;\" alt=\"gas-plant-wireless-monitoring-industrial-cellular-automation-system-remote-monitor-control-process-solutions-corp-texas-square\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/gas-plant-wireless-monitoring-industrial-cellular-automation-system-remote-monitor-control-process-solutions-corp-texas-square_480x480.jpg?v=1771016330\"\u003e\u003c\/div\u003e\n\u003cp\u003eOur gas plant monitoring systems bring unprecedented safety and insight to your operations. By bringing all data to one convenient dashboard, operators can quickly see all aspects of their plant. This provides total process oversight and allows operators to easily identify if equipment is not performing as expected. Thus, our industrial wireless monitoring systems help prioritize maintenance schedules to prevent downtime and optimize budgets. Furthermore, these metrics along with data points on gas detectors help increase plant safety and our gas plant monitoring systems even offer alarms to ensure safety comes first.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eremote monitoring of equipment and processes with data compiled usefully in an online dashboard\u003c\/li\u003e\n\u003cli\u003elow cost of implementation with no copper wires necessary; use existing equipment and sensors\u003c\/li\u003e\n\u003cli\u003eincrease operator safety and prioritize maintenance budgets and labor\u003c\/li\u003e\n\u003cli\u003edecrease maintenance costs, reduce downtime, and eliminate unexpected equipment failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eCNG Gas Compressor Station\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg style=\"margin-left: 25px; float: right;\" alt=\"Natural-Gas-Compressor-Station-Remote-Monitoring-Wireless-Process-Solutions-Corp\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Natural-Gas-Compressor-Station-Remote-Monitoring-Wireless-Process-Solutions-Corp_480x480.png?v=1771016291\"\u003e\u003c\/p\u003e\n\u003cp\u003eGet near real-time monitoring of CNG gas compressor stations with Process Solutions Corp. The process is simple - our engineers will discuss your specific needs and help develop a system that assists you with achieving your remote monitoring goals. Whether new builds or retrofitting an existing operation, our industrial wireless monitoring systems can transmit any signal output directly to your existing DCS, PLC, etc. In addition, we can bring the same data to a cloud-based portal to provide easy online oversight of your data, performance trends, and predictive analysis. Our in-house software designers can provide a quick turn around at a price that has opened the door to numerous of our existing users. Typically, the entire process can take as little as 1 to 3 months and we provide on-going software improvements over time.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eseamlessly collect all your data and bring it back to the control room\u003c\/li\u003e\n\u003cli\u003eour wireless transmitters can retrofit into your existing operation, thus saving time and money to implement\u003c\/li\u003e\n\u003cli\u003eas an option, data can then integrate to cloud software that we develop in-house and host on our secure servers, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/aws.amazon.com\" title=\"Amazon Web Services\" target=\"_blank\"\u003eAWS\u003c\/a\u003e, or on your own server at your direction and preference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eTank  Monitoring\u003c\/h4\u003e\n\u003cp\u003eWe currently provide real-time monitoring for stationary tanks as well as truck fleets. From tank level and pressure measurement to temperature monitoring and real-time fill \/ empty tracking, we can track inventory in real-time, provide records for custody transfer, and more. Your system can also include any custom metric or data point in the monitoring system. If monitoring tanker trucks, beyond monitoring the product and tank status, we can also monitor the health of the truck including GPS location, brake temperature, tire pressure and temperature, and more. Real-time monitoring provides safety for personnel, equipment, and the environment and can help prevent unnecessary downtime.\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eremotely track product flow, fill \/ empty levels, tank pressure, tank temperature, and more\u003c\/li\u003e\n\u003cli\u003emonitor truck fleet location, tank pressure, tire temperature and pressure, brake temperature, on-board cameras, and more\u003c\/li\u003e\n\u003cli\u003ecompatible with \u003ca href=\"https:\/\/www.psctexas.shop\/products\/sae-j1939-controller\" title=\"SAE J1939 Protocol\"\u003eSAE J1939\u003c\/a\u003e truck automation, provides local display for the driver as well as remote monitoring for operators\u003c\/li\u003e\n\u003cli\u003ereduce and prioritize maintenance activities while increasing personnel, equipment, and environmental safety\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878431842435,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/smartphone-gas-cylinder-monitoring-system-gas-bottle-tracking-software-process-solutions-corp-texas_7e2993d8-2685-45c4-9032-a1c780226f6d.jpg?v=1763386562"},{"product_id":"insertion-flow-meter-master-touch-9800mp-haz-fat","title":"Insertion Flow Meter, Master-Touch 9800MP HAZ FAT","description":"The Master-Touch 9800MP HAZ FAT \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/industrial-flow\/insertion-flow-meters\/\"\u003einsertion flow meter\u003c\/a\u003e is a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/flow-sensor\/thermal-mass-flow\/\"\u003ethermal mass flow meter\u003c\/a\u003e for gases. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built upon the ceramic substrate and then receive a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, and relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream and is controlled by the temperature sensor as well as the bridge circuitry. The bridge maintains the overheat temperature and also counterbalances the temperature effects through EPI's proprietary temperature compensation techniques. \u003cul\u003e \u003cli\u003eFeatures a certification for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous locations\u003c\/a\u003e (HAZ) with an explosionâproof enclosure, thus ensuring safe operation in classified environments.\u003c\/li\u003e \u003cli\u003eEmploys Flow Averaging Tube (FAT) technology to average multiple sensing points and deliver accurate \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003emass flow measurements\u003c\/a\u003e, even in short straightârun ducts.\u003c\/li\u003e \u003cli\u003eProvides direct mass flow output without the need for separate temperature or pressure compensation, thus simplifying system integration and control.\u003c\/li\u003e \u003cli\u003ePerfect for easy insertion style mounting into existing pipelines or ducts, which minimizes installation costs as well as downtime.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMaster-Touch 9800MP Insertion Flow Meter for Hazardous Locations\u003c\/h3\u003e Insertion style thermal mass flow meters include a sensor and probe assembly that inserts into the process gas flow conduit. This allows the process gas to flow across the flow inlet tube. Master-Touch 9800MP insertion flow meters are available with 1\/2\", 3\/4\", or 1\" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. The tube length is determined by the size of the process pipe. Large ducts or stacks may require multiple averaging tubes to achieve the very best accuracy. For problematic or unique installations, please consult the factory. Integral style thermal mass flow meters have all the electrical components and connections Â within one enclosure. This enclosure offers a rating for hazardous environments. The enclosure can mount directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eFlow Averaging Thermal Mass Flow Meter from Eldridge Products Inc. (EPI)\u003c\/h3\u003e Our patented Flow Averaging Tubes (FAT) use the principle of convective heat transfer to directly measure mass flow and are suitable for most applications with limits in available straight run. In many installations, the up-stream straight run can reduce to three diameters. The probe has several large diameter inlet ports along the length of the upstream impact surface. The pressure at each inlet port averages inside the tube to create the axial flow through the tube and across the flow sensor. The gas returns to the main flow stream through the ports near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still some require minor adjustment to achieve the best accuracy. \u003ch3\u003eSuperior Insertion Flow Measurement and Calibration\u003c\/h3\u003e EPI insertion flow meters provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. In addition, each flow meter features calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" rel=\"noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. \u003cul\u003e \u003cli\u003eAccuracy: Â±(1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e \u003cli\u003eRepeatability: Â±0.2% of full scale\u003c\/li\u003e \u003cli\u003eSensor response time: 1 second to 63% of final value\u003c\/li\u003e \u003cli\u003eGas temperature coefficient (GTC): 0.02% full scale\/ËC\u003c\/li\u003e \u003cli\u003eGas pressure effect: negligible over Â±50% of factory calibration pressure\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMaster-Touch 9800MP HAZ FAT for Hazardous Locations\u003c\/h3\u003e EPIâs HAZ series full assembly is suitable for use in hazardous locations with T2, T3, and T4 approvals available in domestic and also in international markets. The diecast aluminum, \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA Type 4X\u003c\/a\u003e watertight enclosure is both flame and explosion-proof and features a corrosion resistant finish. \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eDomestic: CSA\/CUS\u003c\/a\u003e \u003cul\u003e \u003cli\u003eClass1 Group B, C, D\u003c\/li\u003e \u003cli\u003eClass2 Group E, F, G\u003c\/li\u003e \u003cli\u003eClass3\u003c\/li\u003e \u003cli\u003eNEMA Type 4X\u003c\/li\u003e \u003c\/ul\u003e International: T2, T3, and T4 \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" target=\"_blank\" rel=\"noopener\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"noopener\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.kosha.or.kr\/extapp\/english\/index.do\" target=\"_blank\" rel=\"nofollow noopener\"\u003eKOSHA\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2025\/10\/Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-30274 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2025\/10\/Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas.jpg\" alt=\"Insertion-Flow-Meter-EPI-Master-Touch-9800MP-Haz-Fat-Eldridge-Products-Inc.-Thermal-Mass-Flowmeter-Process-Solutions-Corp-Texas\" width=\"1000\" height=\"689\"\u003e\u003c\/a\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878434660483,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Series-9800-MP-Insertion-probe-FAT-flow-averaging-tube-thermal-flow-meter-eldridge-products-psc-texas.png?v=1763386612"},{"product_id":"multipoint-flow-meter-master-touch-series-9000mp","title":"Multipoint Flow Meter, Master-Touch Series 9000MP","description":"\u003cp\u003eFor applications that require advanced multipoint measurements of thermal mass flow, the 9000MP Multipoint flow meter is the essential choice for you. This sensor flow enclosure on this multipoint flow meter system, from Eldridge Products Inc. (EPI) is highly durable and can be in service in wet, corrosive and high temperature environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel continuous hinge and stainless steel corner screws\u003c\/li\u003e\n\u003cli\u003eMaintenance free and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eGaskets are made from continuously poured polyurethane foam\u003c\/li\u003e\n\u003cli\u003eThe remote enclosure is also durable and watertight\n\u003cul\u003e\n\u003cli\u003eFlat cover with bonded window\u003c\/li\u003e\n\u003cli\u003eStainless steel continuous hinge as well as stainless steel corner screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAble to effectively function in any large air intake ducts, air exhausts, or flue stacks, these dynamic and advanced flow meters deliver unparalleled service. Perfect for large industry settings and currently in use at many pulp and paper mills and also power source companies across the world, the Series 9000MP is the pinnacle of large-scale thermal mass flow insertion flow meters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMultipoint Flow Meter, Master-Touch Series 9000MP\u003c\/h2\u003e\n\u003cp\u003eA unique feature of the 9000MP multipoint flow meters is that they can integrate an optional Air Purge System, which provides a simple way to clean the sensors. This feature is completely dynamic, giving you control over duration as well as frequency with EPI’s state-of-the-art Master-Touch Software.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerfect for large scale industry operations\u003c\/li\u003e\n\u003cli\u003eMultiple probe system for reliability\u003c\/li\u003e\n\u003cli\u003eReplaceable and removable sensors\u003c\/li\u003e\n\u003cli\u003eConstant and Trustworthy monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaster-Touch products include a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, and also stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance.\u003c\/p\u003e\n\u003cp\u003eThe sensor assembly is large, rugged, in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through EPI's proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMaster-Touch 9000MP Multigen Multiple Point Insertion Flow Meter\u003c\/h2\u003e\n\u003cp\u003eMaster-Touch Multigen multiple point flow meters provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter offers calibration using standards traceable to the National Institute of Standards and Technology (\u003ca href=\"https:\/\/www.nist.gov\" target=\"_blank\" title=\"National Institute of Standards and Technology\" rel=\"noopener\"\u003eNIST\u003c\/a\u003e).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ±(1% of reading + 0.5% of full scale + GTC)\u003c\/li\u003e\n\u003cli\u003eRepeatability: ±0.2% of full scale\u003c\/li\u003e\n\u003cli\u003eSensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003eGas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003eGas pressure effect: negligible over ±50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e9000MP Multipoint Flow Meter for Gas Flows\u003c\/h2\u003e\n\u003cp\u003eMultipoint flow meter systems measure gas flows where two or more sensing points are necessary due to large cross-sectional areas, such as large air intake ducts, air exhaust, or flue stacks. Master-Touch 9000MP Multipoint flow meter Systems are widely in use throughout the world, providing our customers with years of steady, reliable service. In combination with EPI's new Air Purge System, Master-Touch 9000MP multiple point flow systems are ideal to an even greater variety of industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe probe design supports applications as diverse as ambient air flows in HVAC ducts, exhaust gas in large diameter stacks, boiler NOx efficiency systems, and municipal waste incinerators. Our customers include global companies for example, environmental\/ HVAC system integrators, pulp and paper mills, power and energy companies, etc. The configuration and installation options support facility retrofits as well as the most modern new construction requirements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eConfiguration of the EPI Master-Touch Thermal Mass Flowmeter\u003c\/h2\u003e\n\u003cp\u003eThe Master-Touch 9000MP Multipoint System includes one or more 9000MP probes and a 9600MP System Control Panel. The 9000MP flow transmitter probe assembly is the heart of the system. The probe assembly typically has two or more flow sensors mounted in a 1.5\" OD probe shaft. The 9000MP probe’s sensors are removable for field replacement in case of damage. Each sensor matches to its own bridge board and microprocessor to function, in effect, as a complete flow meter.\u003c\/p\u003e\n\u003cp\u003eThe linearized output signals from the multiple sensor assemblies in each probe average to create one overall probe output signal. The probe’s average output signal transmits to a Master-Touch 9600MP System Control Panel (SCP). If the installation contains more than one probe, the output signals from all the probes transmit to the SCP. Then, the SCP averages the values to create one system output. The System Control Panel is housed in a 12\" x 10\" \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eNEMA 4X\u003c\/a\u003e fiberglass enclosure.\u003c\/p\u003e\n\u003cp\u003eThe SCP provides the power for the probe assemblies and receives the average outputs over a four-wire cable to each probe. It also includes its own microprocessor assembly for system-level control and flow display. The SCP provides two analog output signals (0–5 VDC and 4–20 mA), as well as RS232 \u0026amp; RS485 \u003ca rel=\"noopener\" href=\"https:\/\/www.modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus RTU\u003c\/a\u003e communications. The 4–20 mA grand average output can drive up to 1200 ohms.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOptional Air Purge System\u003c\/h2\u003e\n\u003cp\u003eThe optional Air Purge System (APS) provides a means of cleaning the sensors in applications where particulates cause problems. Operators can externally control the frequency and duration of the purge cycle or by using the Master-Touch software. The system can also be set to maintain the flow rate at its level when the purge is active. This important option preserves the integrity of the flow rate and elapsed total data which might otherwise be compromised by the flow of the purge gas.\u003c\/p\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs).  A 316 Stainless Steel sheath encapsulates the platinum sensing element wire or, if necessary, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD with the other RTD acting as the temperature reference.\u003c\/p\u003e\n\u003cp\u003eThe process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003c\/p\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878434726019,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-EPI-thermal-mass-multipoint-flowmeter-flue-gas-measurement-process-solutions-texas.png?v=1763386613"},{"product_id":"turbine-flow-meter-tm-series","title":"Turbine Flow Meter - TM Series","description":"\u003cp\u003eOur liquid turbine flow meters come in a comprehensive variety of offerings, accuracy, and impressive temperature operating ranges. All of our in-line meter series (installed within a length of pipe) and the wafer-style turbine meters (typically inserted between two flanges) are precision machined stainless steel. They are also available in a wide variety of materials of construction.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"product_title\"\u003eTM Series – Liquid Inline Turbine Flow Meters\u003c\/h2\u003e\n\u003cdiv class=\"product_desc\"\u003eThe TM Series Liquid Inline Flow Meter is a highly­ versatile product line that offers all stainless steel, precision-machine components with CD4MCu and\/or 416 stainless steel rotors. These flow meters are ideal for liquid applications and are available with a variety of process connections, including threaded, flanged, and Victaulic. This series provides ±1.0% standard linearity and is repeatable to ±0.10% over the entire flow range. These turbine flow meters have a unique K-factor that is NIST-traceable to factory or independent laboratory calibration.\n\u003cul\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eAccuracy Over Range: ±1.0% (model TM0038 ±2.0%)\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eOperating Temperature: -100 to 800˚F\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eLine Sizes: from 3\/8 inch through 10 inches\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eRepeatability Over Flow Range: ±0.10%\u003c\/li\u003e\n\u003cli\u003eLine Sizes: from 3\/8″ to 10″\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eCertifications: \u003ca href=\"https:\/\/www.iso.org\/iso-9001-quality-management.html\" target=\"_blank\" title=\"ISO Certification\" rel=\"noopener\"\u003eISO9001\u003c\/a\u003e, AS9100, 3A, NIST, NTEP, CTEP, OIML R81\/R117\/MID, CSA, Intrinsic Safety and Canadian CRN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Turbines, Inc.","offers":[{"title":"Default Title","offer_id":46584285036675,"sku":"TM Series","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Turbine-Flow-Meter-Turbines-Inc-TM-Series-In-Line-Liquid-Flow-Meters-Process-Solutions.png?v=1763386402"},{"product_id":"turbine-flow-meter-ha-series","title":"Turbine Flow Meter - HA Series","description":"\u003cp\u003eOur liquid turbine flow meters come in a comprehensive variety of offerings, accuracy, and impressive temperature operating ranges. All of our in-line meter series (installed within a length of pipe) and the wafer-style turbine meters (typically inserted between two flanges) are precision machined stainless steel. They are also available in a wide variety of materials of construction.\u003c\/p\u003e\n\u003cdiv class=\"product_desc\"\u003e\n\u003cdiv class=\"product_desc\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"product_title\"\u003eHA Series – High Accuracy Turbine Meter\u003c\/h2\u003e\n\u003cdiv class=\"product_desc\"\u003eOur High Accuracy Turbine Meters are built with extremely tight tolerances that are achievable with our precision manufacturing processes, stringent quality control, and in-house calibration capabilities. The HA series is able to meet or exceed the strict standards often necessary for custody transfer applications. These High Accuracy Turbine Meters deliver ±0.5% or better accuracy and ±0.1 % repeatability for clean low viscosity fluids. These turbine flow meters, from Turbines, Inc., have a unique K-factor with  NIST-traceable from the factory or independent laboratory calibration.\n\u003cul\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eFlow Rates: from 1 to 12,000 gpm\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003ePressure: up to 20,000 psi\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eAccuracy Over Range: ±0.5% (premium accuracy of 0.25% is available)\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eRepeatability Over Flow Range: ±0.10%\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eOperating Temperature: -450 to 850˚F\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eLine Sizes: from 1\/2 inch through 12 inches\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eCertifications: \u003ca title=\"ISO Certification\" href=\"https:\/\/www.iso.org\/iso-9001-quality-management.html\" rel=\"nofollow noopener\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e, AS 9100, CRN\u003c\/li\u003e\n\u003cli\u003eHighly configurable materials of construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Turbines, Inc.","offers":[{"title":"Default Title","offer_id":46584286478467,"sku":"HA Series","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Turbines-Inc-High-Accuracy-Turbine-Flow-Meter-Inline-Flowmeter-Process-Solutions-Texas.jpg?v=1770921633"},{"product_id":"turbine-flow-meter-wm-series","title":"Turbine Flow Meter - WM Series","description":"\u003cp\u003eOur liquid turbine flow meters come in a comprehensive variety of offerings, accuracy, and impressive temperature operating ranges. All of our in-line meter series (installed within a length of pipe) and the wafer-style turbine meters (typically inserted between two flanges) are precision machined stainless steel. They are also available in a wide variety of materials of construction.\u003c\/p\u003e\n\u003cdiv class=\"product_desc\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"product_title\"\u003eWM Series Liquid Wafer-Style Turbine Flow Meter\u003c\/h2\u003e\n\u003cdiv class=\"product_desc\"\u003eWM Liquid Wafer Style Turbine flow meter is a highly-versatile product line that offers all stainless steel, precision-machine components with CD4MCu and\/or 416 stainless steel rotors in line sizes from 3\/8″ through 10.0″. The WM Series turbine meters are ideal for installation between two raised‐face flanges and the robust design handles up to 6,000 PSI, depending on the selected meter and flange size. These turbine flow meters are unique in that rather than snap rings holding the internals, three (3) machine screws hold each rotor support in place. This design makes it a heavy duty meter for most any liquid application. The WM Series provides ±1.0% standard accuracy, and is repeatable to ±0.10% over the entire flow range. These turbine flow meters offer a unique K-factor with NIST-traceable factory calibration.\n\u003cul\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eFlow Rates: from 0.3-5500 GPM (10-190,000) BPD\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003ePressure: up to 3,700 psig\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eAccuracy Over Range: ±1.0% (model WM0038 ±2.0%)\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eLine Sizes: from 3\/8 inch through 10 inches\u003c\/li\u003e\n\u003cli data-gc-list-depth=\"1\" data-gc-list-style=\"bullet\"\u003eCertifications: ISO 9001, AS 9100, CRN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Turbines, Inc.","offers":[{"title":"Default Title","offer_id":46584291950723,"sku":"WM Series","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Turbine-flow-meter-wm-series-liquid-water-style-turbine-flow-meter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770920997"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/collections\/EPI-Eldrige-Products-Inc-Thermal-Mass-Flow-Meter-Liquid-Flowmeter-for-Industrial-Automation-Flow-Measurement-Process-Solutions-Corp-PSC-Texas.jpg?v=1771538524","url":"https:\/\/www.psctexas.shop\/collections\/industrial-flow-meters.oembed","provider":"Process Solutions Corp.","version":"1.0","type":"link"}