{"title":"Magnetic Flow Meters (Magmeters)","description":"","products":[{"product_id":"watermaster-electromagnetic-flowmeter","title":"WaterMaster Electromagnetic flowmeter","description":"\u003cul\u003e \u003cli\u003eOIML R49 and MID approved\u003c\/li\u003e \u003cli\u003eSuperior control through advanced sensor design\u003c\/li\u003e \u003cli\u003eSubmersible and buriable installation options\u003c\/li\u003e \u003cli\u003eImproved performance through digital signal processing (DSP)\u003c\/li\u003e \u003cli\u003eIntuitive navigation and configuration\u003c\/li\u003e \u003cli\u003eSpeed, ease and security in the field\u003c\/li\u003e \u003cli\u003eDetailed diagnostics for rapid decision making\u003c\/li\u003e \u003cli\u003eSensor size ranges: Full-bore FEV DN40 to 200 mm (11\/2 to 8 in.), FEW DN10 to 2400 (3\/8 to 96 in.), FEF DN250 to 600 (10 to 24 in.) \/ reduced-bore FER DN40 to 600 (11\/2 to 24 in.)\u003c\/li\u003e \u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45878360506499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Watermaster-1.jpg?v=1763385093"},{"product_id":"waterflux-3070-battery-powered-magmeter","title":"WATERFLUX 3070, Battery Powered Magmeter","description":"\u003cp\u003eThe WATERFLUX 3070 is a battery powered magmeter, or electromagnetic water meter, for use in water and wastewater applications such as in water abstraction wells, district metering areas (DMA), and custody transfer measurement of potable water (MI-001, OIML R49). With optional pressure and temperature sensors, this magmeter can also be of use in leak detection, quality control, and pressure management systems.\u003c\/p\u003e\n\u003cp\u003eUnlike mechanical water meters, the WATERFLUX 3070, from KROHNE, is maintenance-free and offers a much larger turn down ratio (1000:1). Its measuring tube, with a rectangular and reduced cross-section, enables a stable measurement even at low flow rates. Due to the optimization of the flow profile, the WATERFLUX 3070 can install virtually anywhere without straight inlet or outlet runs. For example, it functions behind pipe bends, slide valves, or near a reduction in the pipe. Furthermore, burial installation options or use in areas that frequently flood is available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eintegrated temperature and pressure measurement for leak monitoring\u003c\/li\u003e\n\u003cli\u003ecustody transfer: MI-001, OIML R49 up to DN600 \/ 24 inches\u003c\/li\u003e\n\u003cli\u003eno inlet \/ outlet runs requirements\u003c\/li\u003e\n\u003cli\u003ewith custody transfer approval for heat meter applications (MID MI-004)\u003c\/li\u003e\n\u003cli\u003ecompact or field mount versions available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the WATERFLUX 3070 Battery Powered Magmeter*\u003c\/h2\u003e\n\u003cp\u003eThis magmeter is available for battery-powered operation with integrated batteries or optional external battery pack (PowerBlock). However, the WATERFLUX 3070 offers multiple power supply options. For locations with mains power supply, an optional FlexPower unit is available to connect the battery powered magmeter to a 110-230V AC or 10-30V DC power source on site. For example, it can receive power from an electrical grid, a solar panel, or a small windmill.\u003c\/p\u003e\n\u003cp\u003eWhen a permanent transmission of multi-parameter measurement readings, such as flow, pressure, or temperature is desirable, \u003ca title=\"Modbus Protocol\" href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e communication is available as a simple interface. For remote or difficult to access measurement points, such as abstraction wells, the water meter can use a GPRS or 3G module for remote transmission of readings. Furthermore, the OPTICHECK service tool can provide a full on-site verification of the WATERFLUX 3070 without process interruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e\n\u003cli\u003eunique rectangular sensor design for good low flow performance\u003c\/li\u003e\n\u003cli\u003eavailable with patent virtual reference electrode, so no grounding rings are necessary\u003c\/li\u003e\n\u003cli\u003ehigh accuracy at peak flows during the day and at low flows during the night\u003c\/li\u003e\n\u003cli\u003esensor tube with \u003ca title=\"Arkema - Rilsan Coating\" href=\"https:\/\/www.arkema.com\/usa\/en\/product\/technicalpolymers\/rilsan-family-products\/rilsan-pa11\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eRilsan coating\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e\n\u003cli\u003esuitable for immersion in flood chambers\u003c\/li\u003e\n\u003cli\u003ebattery powered magmeter for remote locations or mains powered with battery backup\u003c\/li\u003e\n\u003cli\u003eFlexPower option for power connection to electrical grid, solar panel, or windmill\u003c\/li\u003e\n\u003cli\u003eunique low power Modbus option for battery powered magmeter version\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eUnique Rectangular Design\u003c\/h2\u003e\n\u003cp\u003eThe strengths of the WATERFLUX 3000 Series lies in its unique construction with a rectangular cross section and its efficient coil construction. The coils provide a stronger and more homogeneous magnetic field, leading signal to noise ratio improvements. The measurement, therefore, is independent of the flow profile, so measurements are very stable. This results in a very good low flow performance with a minimal pressure drop and a minimal impact on the pressure strategy of the network.\u003c\/p\u003e\n\u003cp\u003eBecause of the unique WATERFLUX 3000 flow sensor design, whereby the mean flow velocity and flow profile are optimized within the rectangular and reduced cross-section, the additional uncertainty for upstream disturbances is drastically reduced. The water meter can install directly behind an elbow or reducer in the pipe without a straight inlet or outlet lengths. A substantial reduction of the inlet and outlet section requirements offers the option to reduce the size of the measurement pits. The Rilsan coating of the flow sensor is chemically resistant, durable, and maintenance-free. In addition, the coating is flexible and tough, smooth and pore-free, and free of solvents. The coating is in wide use in the water industry and offers a wide range of drinking water certifications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eCommon Applications for a Battery Powered Magmeter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater and wastewater applications\u003c\/li\u003e\n\u003cli\u003eremote monitoring of water supplies and distribution networks\u003c\/li\u003e\n\u003cli\u003ewater consumption and fiscal metering (custody transfer)\u003c\/li\u003e\n\u003cli\u003eirrigation and abstraction\u003c\/li\u003e\n\u003cli\u003ewater treatment\u003c\/li\u003e\n\u003cli\u003ereplacement of mechanical turbine meters\u003c\/li\u003e\n\u003cli\u003eleak detection\u003c\/li\u003e\n\u003cli\u003echecking of pumps and water wells\u003c\/li\u003e\n\u003cli\u003ecustody transfer flow measurement in district heating networks\u003c\/li\u003e\n\u003cli\u003emeasurement of potable water\u003c\/li\u003e\n\u003cli\u003emeasurement of raw water\u003c\/li\u003e\n\u003cli\u003eoutlet of water purification plants\u003c\/li\u003e\n\u003cli\u003emonitoring distribution networks\u003c\/li\u003e\n\u003cli\u003ewater consumption as well as billing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878360539267,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-waterflux-3070-battery-powered-magmeter-municipal-water-utility-wastewater-treatment-water-flow-measurement-psc-texas.png?v=1763385094"},{"product_id":"tidalflux-2300-magmeter-for-partially-filled-pipes","title":"TIDALFLUX 2300, Magmeter for Partially Filled Pipes","description":"\u003cp\u003eThe TIDALFLUX 2300 is an electromagnetic flow meter (EMF), or magmeter, with patented, capacitive level measurement for use in partially filled pipes (up to DN1600 \/ 64 inches). This magmeter is the ideal solution for flow measurement of municipal or industrial wastewater in pressureless transport lines. However, this magnetic flow meter is also suitable for measurement of effluent brine from seawater and well water injection applications. Unlike open channel systems (Venturi, V-notches etc.) these inline flow meters are a closed measuring solution without obstructions. In addition, these magmeters offer a much better accuracy at lower total costs of ownership.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eintegrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)\u003c\/li\u003e\n\u003cli\u003eelectrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface\u003c\/li\u003e\n\u003cli\u003e220\/110 V or 24 VDC power supply\u003c\/li\u003e\n\u003cli\u003eaccurate (±1%) and cost-saving alternative to open channel systems\u003c\/li\u003e\n\u003cli\u003eflange: DN200 to DN1600 \/ 8 to 64 inches\n\u003cul\u003e\n\u003cli\u003evarious flange standards like DIN, ANSI and JIS\u003c\/li\u003e\n\u003cli\u003epolyurethane liner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 x 4-20 mA, pulse, HART, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus\u003c\/a\u003e, as well as \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.profibus.com\" target=\"_blank\" title=\"PROFINET Protocol\"\u003ePROFINET\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the TIDALFLUX 2300 Magmeter for Partially Filled Pipes*\u003c\/h2\u003e\n\u003cp\u003eThe measuring tube of the TIDALFLUX 2300, from KROHNE, comes with a polyurethane (PUR) liner for abrasion and chemical resistance. Its smooth surface prevents build-up of fat and other deposits which minimizes the need for regular cleaning. For direct burial installation or applications in areas that can be partially flooded, this flow meter can also offer IP68 \/NEMA 6P versions. Due to the presence of flammable hydrogen sulphide (H\u003csmall\u003e2\u003c\/small\u003eS) in many wastewater applications, this magmeter also has ATEX \/ IECEx zone 1 approval. Furthermore, the TIDALFLUX 2300 comes with extensive diagnostics. In addition, the OPTICHECK service tool can carry out full on-site verification of these flow meters without process interruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e\n\u003cli\u003eclosed measurement solution with patented integrated non-contact level measurement\u003c\/li\u003e\n\u003cli\u003efor effluent and slurries in gravity pipelines \/ sewers\u003c\/li\u003e\n\u003cli\u003echemically and also abrasion resistant PUR liner\u003c\/li\u003e\n\u003cli\u003eaccuracy: ±1% of measured value (MV)\u003c\/li\u003e\n\u003cli\u003eelectrodes not in contact with floating deposits\u003c\/li\u003e\n\u003cli\u003eoptional version for direct burial installation and flooded areas (\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP68\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003estandard factory calibration, also no on-site calibration requirements\u003c\/li\u003e\n\u003cli\u003eextensive flow meter and process diagnostics, which exceed the NE 107 requirement\u003c\/li\u003e\n\u003cli\u003ealso for use in hazardous areas zone 1: ATEX, IECx Zone 1, Class 1 Div 2\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eCommon Applications of this Magmeter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater and wastewater applications in partially filled and gravity feed pipes\u003c\/li\u003e\n\u003cli\u003ecost-effective replacement of expensive siphon tube constructions\u003c\/li\u003e\n\u003cli\u003esurface water flow measurement\u003c\/li\u003e\n\u003cli\u003ebiological and also chemical wastewater\u003c\/li\u003e\n\u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e\n\u003cli\u003ecombined sewer overflows (CSOs)\u003c\/li\u003e\n\u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e\n\u003cli\u003erainwater retention basins\u003c\/li\u003e\n\u003cli\u003einfluent \/ intake as well as effluent at wastewater treatment plants\u003c\/li\u003e\n\u003cli\u003edischarge to surface water\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363750531,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/krohne-tidalflux-2300-magmeter-for-partially-filled-pipes-flow-measurement-electromagnetic-flow-meter-process-solutions-corp_42b2897a-4911-4e0f-be7b-b6b63ece52df.png?v=1763385143"},{"product_id":"af-e-400-magmeter-for-chemical-dosing","title":"AF-E 400 Magmeter for Chemical Dosing","description":"Compact, robust, reliable, and cost-effective: these are important characteristics of instrumentation in industrial automation. The AF-E 400 is the culmination of \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e expertise in a best-in-class \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter, or magmeter\u003c\/a\u003e. Its unique \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact sensor design\u003c\/a\u003e makes it ideal for use in tight spaces and for parallel installations in a variety of conductive liquid applications such as chemical dosing. The reliable round bore reduction limits pressure drops and ensures strength and accuracy under pressure. Furthermore, the cost-effective integrated temperature measurement eliminates the need for an additional temperature measurement device. \u003cul\u003e \u003cli\u003enarrow installation width\u003c\/li\u003e \u003cli\u003ehigh-temperature capability\u003c\/li\u003e \u003cli\u003eintegrated temperature sensor\u003c\/li\u003e \u003cli\u003emulti-IO-link, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, or double analog output option\u003c\/li\u003e \u003cli\u003ehighest flow and low absolute uncertainty per diameter\u003c\/li\u003e \u003cli\u003evarious threaded connections directly on the device (no adapters needed)\u003c\/li\u003e \u003c\/ul\u003e \u003cimg class=\"alignright wp-image-25531 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/krohne-af-e-400-magmeter-for-chemical-dosing-compact-magnetic-flow-meter-process-solutions-corp.jpg\" alt=\"krohne-af-e-400-magmeter-for-chemical-dosing-compact-magnetic-flow-meter-process-solutions-corp\" width=\"750\" height=\"553\"\u003e \u003ch3 style=\"text-align: left;\"\u003eAF-E 400 Magmeter for Chemical Dosing\u003c\/h3\u003e The AF-E 400 is an electromagnetic flow meter for \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003eutility applications\u003c\/a\u003e such as flow monitoring in sludge treatment processes. This ultra-compact magmeter is the ideal choice for applications with conductive liquids in tight spaces such as on chemical dosing skids. It features best-in-class accuracy in every flow range, thus allowing optimal processing in automation. The round bore reduction of the sensor makes this \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e more resilient in terms of increased pressure, while ensuring high accuracy over a wide pressure and temperature range. Its integrated temperature measurement eliminates the need for an additional sensor. The AF-E 400 guarantees maximum flexibility when it comes to installation. Due to the special design of its magnetic circuit, field strength, and electronics, this magmeter can install in extreme proximity to one another (as close as 2 mm \/ 0.08\"). Thus, it can mount in parallel without interference. Furthermore, this electromagnetic flow meter offers various output and communication options. Among others, the device features an IO-Link and a Modbus option to provide operators with multiple sensor and application data. IO-Link also enables faster sensor installation or replacement. \u003ch3 style=\"text-align: left;\"\u003eFeatures of the AF-E 400 Magmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003emeasurement of flow rate, totalized flow, and temperature - up to 194ËF (90ËC)\u003c\/li\u003e \u003cli\u003erobust casted stainless steel housing (2 mm \/ 0.08\" thickness)\u003c\/li\u003e \u003cli\u003emaintains accuracy over a wide pressure and temperature range\u003c\/li\u003e \u003cli\u003eround bore tube for minimal pressure loss and a high turndown ratio without risk of cavitation\u003c\/li\u003e \u003cli\u003eno cross talk: allows installation in series or in parallel up to a distance of 2 mm \/ 0.08\" from device to device\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMURÂ NEÂ 107\u003c\/a\u003e diagnostics\u003c\/li\u003e \u003cli\u003eIO-Link enables transmission of more process data and automatic device configuration without programming\u003c\/li\u003e \u003cli\u003erotatable full color display\u003c\/li\u003e \u003cli\u003enominal sensor sizes 6, 15, 20, 25 mm for flow rates up to 150 l\/min with G (male) and also NPT or RC (female) threads \u003cul\u003e \u003cli\u003evarious adapters for other thread types available\u003c\/li\u003e \u003cli\u003eadapter solution for 40 and 50 mm for flow rates up to 500 l\/min\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3 style=\"text-align: left;\"\u003eCommon Applications for the AF-E 400 Magmeter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eflow measurement of conductive liquids in utility applications\u003c\/li\u003e \u003cli\u003eflow monitoring in recirculation of hot as well as cold water\u003c\/li\u003e \u003cli\u003edosing skids for reagents and catalysts or chemicals\u003c\/li\u003e \u003cli\u003eflow monitoring in sludge treatment processes\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363783299,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-AFE-400-electro-magnetic-flow-measurement-magmeter-process-solutions-texas_9731a2a3-2370-48d4-a140-71c0ec20184f.png?v=1763385145"},{"product_id":"optiflux-2300-flow-meter-for-water","title":"OPTIFLUX 2300, Flow Meter for Water","description":"The OPTIFLUX 2300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, for all demanding \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e. This high-end \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e for water is particularly suitable for municipal water as well as wastewater applications that require high accuracy and extensive diagnostics. The OPTIFLUX 2300 magmeter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, has the widest diameter range available in the market: DN25 to DN3000 (1 to 120\"). In addition, it complies with requirements for custody transfer (MID MI-001, OIML R49). This flow meter also allows for custody transfer measurement without inlet\/outlet runs (0D\/0D) according to OIML R49 accuracy class 1. Furthermore, it offers a wide range of approvals for potable water. Overall, the OPTIFLUX 2300 is an effective alternative to mechanical water meters, not least in custody transfer measurement of potable water. \u003cimg class=\"alignright wp-image-25901 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas\" width=\"630\" height=\"740\"\u003e \u003cul\u003e \u003cli\u003e0D\/0D installation according to MID MI-001 and OIML R49 accuracy class 1\u003c\/li\u003e \u003cli\u003eflange: DN25 to DN3000 (1 to 120\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, as well as PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.2% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003emeets potable water standards: ACS, DVGW, NSF, TZW, KTW, WRAS, KIWA, etc.\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2300 also features a \"virtual reference\" option, which allows for a measuring mode without the need of additional grounding rings. This feature enables substantial cost savings in terms of installation and procurement. Installation in measurement chambers, which are subject to (constant) flooding, is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. Moreover, the OPTIFLUX 2300 offers various digital communication options, making it a flexible option for many processes. In addition, operators can carry out a full on-site verification of this flow meter for water without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2300 Magnetic Flow Meter for Water*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turn down ratio: up to 1000:1)\u003c\/li\u003e \u003cli\u003eno inlet\/outlet run requirements for OIML R49 class 1 accuracy\u003c\/li\u003e \u003cli\u003ewidest diameter range available in the market\u003c\/li\u003e \u003cli\u003eavailable with patent virtual reference grounding method, which provides cost-saving installation without grounding rings\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner for excellent chemical resistance\u003c\/li\u003e \u003cli\u003eoptions for burial installation and constant flooding (IP68)\u003c\/li\u003e \u003cli\u003elargest diameter range with custody transfer approval\u003c\/li\u003e \u003cli\u003etamper proof\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003eon-site verification of this flow meter for water with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of this Flow Meter for Water Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral as well as advanced municipal water and wastewater applications\u003c\/li\u003e \u003cli\u003ecustody transfer measurement\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer) of potable water\u003c\/li\u003e \u003cli\u003eabstraction as well as irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater treatment plants such as raw water, drinking water, treatment chemicals, and more\u003c\/li\u003e \u003cli\u003ewastewater networks\u003c\/li\u003e \u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e \u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e \u003cli\u003emunicipal wastewater treatment plants\u003c\/li\u003e \u003cli\u003edesalination plants such as for sea water, permeate, brine, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363881603,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2000-Series-Electromagnetic-Flow-Meter-for-Municipal-Water-Magmeter-Process-Solutions-Texas_3ea1af8f-ab42-4515-85e7-a271b6792bb4.png?v=1763385149"},{"product_id":"optiflux-2100-electromagnetic-flowmeter","title":"OPTIFLUX 2100, Electromagnetic Flowmeter","description":"The OPTIFLUX 2100 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flowmeter (EMF), or magmeter\u003c\/a\u003e, for standard \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e. It is the ideal solution for all general \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow applications\u003c\/a\u003e where reliable flow measurement with sufficient yet not extremely high accuracy is necessary. Furthermore, installation in measurement chambers subject to (constant) flooding is possible with the remote \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rated version\u003c\/a\u003e. Its wear resistant liner materials, as well as its full bore design without moving parts, make the OPTIFLUX 2100, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, an effective replacement of mechanical water meters in drinking water distribution networks. Moreover, this electromagnetic flowmeter features a wide range of approvals necessary for potable water measurement. In addition, a full on-site verification of the meter without process interruption can be carried out using the OPTICHECK service tool. \u003cimg class=\"alignright wp-image-25480 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-OPTIFLUX-2100-magmeter-water-flow-measurement-wastewater-treatment-process-solutions-corp-texas.jpg\" alt=\"KROHNE-OPTIFLUX-2100-electromagnetic-flowmeter-magmeter-water-flow-measurement-wastewater-treatment-process-solutions-corp-texas\" width=\"632\" height=\"750\"\u003e \u003ch3 style=\"text-align: left;\"\u003eFeatures of the OPTIFLUX 2100 Electromagnetic Flowmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e \u003cli\u003eoptions for subsoil installation and constant flooding\u003c\/li\u003e \u003cli\u003eproven and unsurpassed life time, huge installed base\u003c\/li\u003e \u003cli\u003estandard wet calibration\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner, which is suitable for low concentrated chemicals\u003c\/li\u003e \u003cli\u003etamper-proof\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.3% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003ediagnostic capabilities, for example: conductivity, electrode error, ambient and process temperature, etc.\u003c\/li\u003e \u003cli\u003efull bore design with no moving parts, no wear, and also no pressure loss\u003c\/li\u003e \u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e \u003cli\u003esuitable for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e such as \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eATEX\u003c\/a\u003e, \u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fmapprovals.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e, \u003ca href=\"https:\/\/www.csagroup.org\/testing-certification\/certification\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eon-site verification of flowmeter with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3 style=\"text-align: left;\"\u003eCommon Uses of the OPTIFLUX 2100 from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e\n\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eall standard \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eabstraction and irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater treatment plants, for example: raw water, drinking water, treatment chemicals, etc.\u003c\/li\u003e \u003cli\u003ewastewater networks\u003c\/li\u003e \u003cli\u003ecombined and separate sewage systems and sludge\u003c\/li\u003e \u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e \u003cli\u003emunicipal wastewater treatment plants\u003c\/li\u003e \u003cli\u003edesalination plants: sea water, permeate, and also brine, etc.\u003c\/li\u003e \u003cli\u003ewater purification\u003c\/li\u003e \u003cli\u003eleakage detection\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eFrom Standard Models to Highly Custom Versions\u003c\/h3\u003e For easy ordering, the standard range of the OPTIFLUX 2000 Series covers all popular sizes, flange materials, and connections (ASME, EN, JIS, AWWA). However, our extensive engineering department can provide solutions for all specifications beyond our standard range. Requests for special sizes, flange connections, pressure ratings, building lengths, and materials will always get a serious review. Whenever possible, we will even engineer an electromagnetic flowmeter that fits your precise requirements. \u003c\/div\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eEasy To Install Electromagnetic Flowmeter\u003c\/h3\u003e Fitting the OPTIFLUX 2000 Series is easy with the flanged design and standard ISO insertion lengths. To further ease the operation, the OPTIFLUX 2000 Series can install without filters and straighteners. Even grounding rings are not necessary with the patented \"Virtual Reference\" option on the IFC 300 signal converter. \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 Rating Options\u003c\/a\u003e\u003c\/h3\u003e Installation in measurement chambers subject to (constant) flooding is possible with the IP68 rating version. The chambers can even be completely surpassed if the IP68 version is combined with our special subsoil coating, thus allowing the OPTIFLUX 2000 to be installed directly in the ground. \u003c\/div\u003e \u003ch3\u003eElectromagnetic Flowmeter for Custody Transfer Processes\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 6\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e In combination with the IFC 300 signal converter, the OPTIFLUX 2000 is suitable for custody transfer applications. It meets the requirements of OIML R49 and can also verify according to Annex MI-001 of the Measuring Instruments Directive (MID) \/ UK Regulation 2016. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364012675,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/OPTIFLUX-2100-krohne-magmeters-magnetic-flow-controller-psc-texas_6d237ab2-7984-4ce8-8b37-df55757d7279.png?v=1763385154"},{"product_id":"optiflux-2050-for-water-flow-measurement","title":"OPTIFLUX 2050 for Water Flow Measurement","description":"The OPTIFLUX 2050 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flowmeter (magmeter)\u003c\/a\u003e for basic and advanced water \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewastewater and municipal water applications\u003c\/a\u003e. It is suitable for all cost-effective measurements where extremely high accuracy, extensive diagnostics, or a wide range of communication options are not a priority. This magmeter has a wide diameter range: DN25 to DN1200 (1 to 48\"). In addition, this magmeter for water flow measurement offers all available approvals for drinking water. The extra isolation of its electronics as well as its special housing makes the OPTIFLUX 2050, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, particularly suitable for use in areas with extreme humidity. \u003cimg class=\"alignright wp-image-25908 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas\" width=\"627\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003eflange: DN25 to DN1200 (1 to 48\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e4-20 mA, pulse, frequency, status, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003erugged liners suitable for any water and wastewater application\u003c\/li\u003e \u003cli\u003eproven and unsurpassed lifetime, huge installation base\u003c\/li\u003e \u003cli\u003edrinking water approvals such as KTW, KIWA, DVGW, ACS, NSF, WRAS\u003c\/li\u003e \u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e \u003cli\u003ecompliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, as well as EN 14154)\u003c\/li\u003e \u003cli\u003eeasy installation and commissioning as well as maintenance-free\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2050 also features a full bore design with wear resistant liner materials. Installation in measurement chambers subject to (constant) flooding is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. This magmeter for water flow measurement comes with current output (including HART) and active pulse\/frequency output in addition to Modbus. Furthermore, operators can carry out a full on-site verification of the OPTIFLUX 2050 without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2050 Magmeter for Water Flow Measurement*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP68 rating\u003c\/a\u003e electronics for use in areas with extreme humidity and chances of flooding\u003c\/li\u003e \u003cli\u003estandard wet calibration\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner: excellent chemical resistance\u003c\/li\u003e \u003cli\u003esignal converter with display or as blind version\u003c\/li\u003e \u003cli\u003etamper proof, fully welded construction, also available in customer specific constructions\u003c\/li\u003e \u003cli\u003efull bore design: no moving parts, no wear, no pressure loss\u003c\/li\u003e \u003cli\u003estandard in house wet calibration of flow sensors up to diameter DN3000\u003c\/li\u003e \u003cli\u003eon-site verification of flowmeter with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses for the OPTIFLUX 2050 for Water Flow Measurement\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eall simple municipal water as well as wastewater applications\u003c\/li\u003e \u003cli\u003eabstraction and irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation and treatment systems\u003c\/li\u003e \u003cli\u003ewater purification and desalination\u003c\/li\u003e \u003cli\u003erevenue metering or billing leakage detection\u003c\/li\u003e \u003cli\u003eirrigation as well as cooling water\u003c\/li\u003e \u003cli\u003esewage and sludge\u003c\/li\u003e \u003cli\u003esea water\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364864643,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Wastewater-Flow-Measurement-Process-Solutions-Corp.png?v=1763385178"},{"product_id":"optiflux-1300-magnetic-flow-meter","title":"OPTIFLUX 1300 Magnetic Flow Meter","description":"The OPTIFLUX 1300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, with a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact\u003c\/a\u003e, lightweight wafer-style design. This magnetic flow meter is an economical solution for applications with conductive liquids (â¥ 5 Î¼S\/cm) in addition to higher solid content (up to 70%). In comparison with the OPTIFLUX 1100, the OPTIFLUX 1300, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, offers better accuracy. Furthermore, this \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e meets the demands of many applications in the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal and wastewater industry\u003c\/a\u003e. This magnetic flow meter is also a preference in dosing systems, compact skids, chemical handling systems, or pump and firefighting systems. \u003cimg class=\"alignright wp-image-25895 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas.jpg\" alt=\"KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas\" width=\"406\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003elightweight as well as compact for easy handling and space saving installation\u003c\/li\u003e \u003cli\u003eaffordable price\u003c\/li\u003e \u003cli\u003eexcellent chemical resistance\u003c\/li\u003e \u003cli\u003eno pressure loss\u003c\/li\u003e \u003cli\u003einsensitive to vibrations\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 1300 features a reinforced PFA liner as well as \u003ca href=\"https:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy\u003c\/a\u003e electrodes that guarantee excellent chemical resistance and a large temperature range up to 248ËF (120ËC). This EMF has no internal moving parts, does not require maintenance, and is also insensitive to vibrations. It comes with various digital communication options and approvals for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e. Furthermore, operators can use the OPTICHECK service tool for full on-site verification of this flow meter without process interruption. \u003ch3\u003eFeatures of the OPTIFLUX 1300 Magnetic Flow Meter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turndown ratio: 1000:1)\u003c\/li\u003e \u003cli\u003elightweight and compact wafer-style (\"sandwich\") design for space saving installation\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.3% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003ereinforced PFA liner: smooth surface, excellent chemical resistance\u003c\/li\u003e \u003cli\u003epipe cross-section without restrictions for slurries with non abrasive solid particles\u003c\/li\u003e \u003cli\u003eno internal moving parts or maintenance requirements\u003c\/li\u003e \u003cli\u003eon-site verification of this magnetic flow meter via OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of a Magnetic Flow Meter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral use in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal as well as wastewater applications\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003emore demanding water applications such as potable water, raw water, wastewater, salt water, heated and cooled water\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer)\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation in addition to treatment systems\u003c\/li\u003e \u003cli\u003edosing systems, filtration systems, and also pump control\u003c\/li\u003e \u003cli\u003ewater flow monitoring\u003c\/li\u003e \u003cli\u003eheat transfer and cooling systems\u003c\/li\u003e \u003cli\u003eviscous flows such as mud, slurry, sludge, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364897411,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optiflux-1300-magnetic-flow-meter-municipal-water-wastewater-flow-measurement-process-solutions-corp.png?v=1763385180"},{"product_id":"mag-view-series-low-flow-magnetic-inductive-flow-meters","title":"MAG-VIEW Series, Low Flow Magnetic Inductive Flow Meters","description":"\u003cul\u003e \u003cli\u003eMake liquid flows visible by pulse output, analog output (4 .. 20 mA) or blinking LED (red\/green)\u003c\/li\u003e \u003cli\u003eNo moving parts (no mechanical wear)\u003c\/li\u003e \u003cli\u003eEase of mounting and operation\u003c\/li\u003e \u003cli\u003eFree pipe cross section, no additional pressure drop\u003c\/li\u003e \u003cli\u003eFast response\u003c\/li\u003e \u003cli\u003eInsensitive with contaminated liquids\u003c\/li\u003e \u003cli\u003eIdeal solution for interference free operation combined with a long-life cycle\u003c\/li\u003e \u003cli\u003eWide independence to the inlet and outlet pipes create the advantage to be able to install in compact machines with cramped confines\u003c\/li\u003e \u003cli\u003eLightweight and compact design\u003c\/li\u003e \u003cli\u003eSuitable for mobile applications\u003c\/li\u003e \u003cli\u003eLow power consumption\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e The fields of application for this magnetic flow meter are diverse: They can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media. The sensor is intended for continuously measuring flow rates or for dosing and batching of electrically conductive liquids with a minimum of 50 ÂµS\/cm. \u003cul\u003e \u003cli\u003eOil and energy\u003c\/li\u003e \u003cli\u003eDrinking and waste water\u003c\/li\u003e \u003cli\u003ePetrochemical production\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eFood\u003c\/a\u003e and beverage manufacturing\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/how-mass-flow-controller-can-support-in-the-pharmaceutical-industry\/\"\u003ePharmaceutical\u003c\/a\u003e and laboratory\u003c\/li\u003e \u003cli\u003eMetals and mining\u003c\/li\u003e \u003cli\u003ePulp and paper\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eMAG-VIEW Series Low Flow Magnetic Inductive Flow Meters Model Line-Up\u003c\/h4\u003e \u003ctable class=\"table\" width=\"100%\"\u003e \u003cthead\u003e \u003ctr class=\"thead\"\u003e \u003cth width=\"33%\"\u003ePulse\/Analog output - PN 10 bar\u003c\/th\u003e \u003cth width=\"33%\"\u003ePulse output - PN 16 bar\u003c\/th\u003e \u003cth width=\"33%\"\u003ePulse\/Analog output - PN 16 bar\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eMVM-001-PNÂ |Â 0.0083 ... 1 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-001-PAÂ |Â 0.0083 ... 1 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-002-QAÂ |Â 0.1 ... 2 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-002-PNÂ |Â 0.05 ... 2 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-002-PAÂ | Â 0.05 ... 2 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-005-QAÂ |Â 0.25 ...Â 5 l\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-020-QAÂ |Â 1.0 ... 20 l\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eMVM-030-PNÂ |Â 0.5 ... 30 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-030-PAÂ |Â 0.5 ... 30 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-050-QAÂ | Â 2.5 ... 50 l\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eMVM-060-PNÂ |Â 1 ... 60 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-060-PAÂ |Â 1 ... 60 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-200-QAÂ |Â 10 ... 200 l\/min\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMVM-250-QAÂ |Â 12.5 ... 250 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-250-PNÂ |Â 5 ... 250 l\/min\u003c\/td\u003e \u003ctd\u003eMVM-250-PAÂ |Â 5 ... 250 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878371909763,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Mag-view.jpg?v=1763385476"},{"product_id":"aqua-master-few431-electromagnetic-flowmeter-enhanced-integral-system-sensor-transmitter","title":"Aqua Master FEW431 Electromagnetic Flowmeter Enhanced Integral System (Sensor + Transmitter)","description":"\u003cstrong\u003eMultiple measurement parameters\u003c\/strong\u003e \u003cul\u003e \u003cli\u003eflow rate, flow velocity, volume flow (forward, reverse and net) and pressure (option)\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eMultiple power options\u003c\/strong\u003e \u003cul\u003e \u003cli\u003ebattery (with up to 10 years life), solar\/wind renewable and AC mains\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eWide range of sensor styles and size\u003c\/strong\u003e \u003cul\u003e \u003cli\u003ereduced bore DN40 to 600, virtual full bore DN40 to 200, full bore DN250 to 2400 and probe 300 to 1000 mm\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eIdeal for arduous applications\u003c\/strong\u003e \u003cul\u003e \u003cli\u003eIP68 for submersion and up to 5m buriable\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eVerification\u003c\/strong\u003e \u003cul\u003e \u003cli\u003ein situ diagnostics and self-checking capabilities\u003c\/li\u003e \u003c\/ul\u003e \u003cstrong\u003eflexible communications\u003c\/strong\u003e \u003cul\u003e \u003cli\u003epulse, Modbusâ¢, and Sensusâ¢ with wireless interface to mobile smartphone\/tablet\u003c\/li\u003e \u003c\/ul\u003e","brand":"ABB","offers":[{"title":"3\" DN080","offer_id":45878379479171,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"4\" DN100","offer_id":45878379511939,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"6\"DN150","offer_id":45878379544707,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/AQ4-4.png?v=1763385574"},{"product_id":"abb-aquamaster3-transmitter-display-magmeter-depreciated","title":"ABB AquaMaster3 Transmitter Display for MagMeter","description":"\u003cp\u003eThe AquaMaster3 Transmitter features mains, renewable energy, and battery-power capabilities. It has a stainless steel housing with a thermoplastic outer and the assembly is seal-for-life to \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68\u003c\/a\u003e as a standard. The transmitter also incorporates military specification plug \u0026amp; socket connections for all inputs and outputs. The transmitter can mount integral with the AquaMaster sensor (integral mount) or remotely from the AquaMaster sensor (remote). This enables the sensor for burial, for example. For integral sensors, the mounting system positions the display so that it is visible from both the top and the side. The AquaMaster 3, from ABB, is a high performance electromagnetic flow meter transmitter for the measurement of electrically-conductive fluids. It is normally available with factory configuration and calibration systems. Full range of power supply options for lowest cost site preparation and energy usage:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC mains\u003c\/li\u003e\n\u003cli\u003eexternal long-life battery pack\u003c\/li\u003e\n\u003cli\u003einternal standard lithium D-cell battery\u003c\/li\u003e\n\u003cli\u003esolar \/ wind-power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE\u003c\/strong\u003e: This is the transmitter only, the flow meter would need to be procured separately.\u003c\/p\u003e\n\u003ch3\u003eAquaMaster 3 Transmitter FET221 Display Replacement with Optional Built-in, Multi-Sampling Rate, Pressure, and Flow Data Logger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater Industry Telemetry Standard (WITS) verification compliant\u003c\/li\u003e\n\u003cli\u003eall-in-one solution\u003c\/li\u003e\n\u003cli\u003ehigh resolution flow and pressure data logger\u003c\/li\u003e\n\u003cli\u003eno need to purchase a separate pressure transmitter or data logger\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWireless Communication via AquaMaster3 Optional Built-in GSM \/ GPRS Modem\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003enear real-time data via WITS GPRS\u003c\/li\u003e\n\u003cli\u003eaccess and download all log data remotely\u003c\/li\u003e\n\u003cli\u003eremote diagnostics\u003c\/li\u003e\n\u003cli\u003ereduces the requirement for costly and time-consuming site visits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFully Self-Contained or Remote AquaMaster3 Transmitter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eintegral sensor \/ transmitter option\u003c\/li\u003e\n\u003cli\u003eremote transmitter option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClass Leading, Fully Potted, IP68 Electronic Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ezero water ingress, even during flood conditions\u003c\/li\u003e\n\u003cli\u003emilitary specification \u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIP68\u003c\/a\u003e plug and socket connections\u003c\/li\u003e\n\u003cli\u003esealed-for-life = zero maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe AquaMaster 3 Transmitter FET221 is Compatible with ABB's Full Range of Industry Leading Flow Sensors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ereduced-bore series for high turn-down applications, for example, leakage detection\u003c\/li\u003e\n\u003cli\u003efull-bore series for general-purpose water metering and irrigation applications\u003c\/li\u003e\n\u003cli\u003eall sensors are buriable, eliminating the need for costly chamber construction â a significant site preparation saving\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFull Range of Approvals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eoptional MID approval\u003c\/li\u003e\n\u003cli\u003eoptional OIML R049 approval\u003c\/li\u003e\n\u003cli\u003eNMI approval pending\u003c\/li\u003e\n\u003cli\u003eWITS version 1.1 verification\u003c\/li\u003e\n\u003cli\u003eWITS version 1.3 self-certification\u003c\/li\u003e\n\u003cli\u003eUL Fire Service approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSMS Mode\u003c\/h3\u003e\n\u003cp\u003eAquaMaster3 has the built in capability of a Quad Band GSM \/ SMS \/ GPRS engine supporting 2 modes of communication â SMS mode and Water Industry Telemetry Standard (WITS) mode. SMS mode enables the user to interrogate the flowmeter data remotely or to have it sent directly to a host server. Flow data records typically every 15 minutes and is sent via SMS message to your server automatically, every day. It's fast, easy, and convenient. Pressure data is optionally sent in a separate message. Thousands of meters are manageable using this solution, which will run your whole network from one server.\u003c\/p\u003e\n\u003ch3\u003eWITS Mode\u003c\/h3\u003e\n\u003cp\u003eWITS modeÂ supports the Water Industry Telemetry Standard open protocol version 1.1, 1.2, and 1.3. It also has WITS verification (independently tested against 2 WITS masters) in V1.1 mode. It delivers near real-time (typically 15 minute connection schedule) flow and pressure data with immediate alarm and event recording. Optionally, 1 minute high-speed log files are available to WITS 1.3 protocol, which offers a WITS self-certification. 1 WITS master can manage thousands of meters using a low-cost GPRS data connection.\u003c\/p\u003e\n\u003ch3\u003eFlow Performance of the AquaMaster3\u003c\/h3\u003e\n\u003cp\u003eWith the widest flow range, optimum accuracy and long term stable calibration, the reduced-bore (FER) performance is OIML R49 type approved (DN40 to DN300) to the latest Class 1 and Class 2 accuracies. This low flow rate capability enables minimal night flow rates for metering. This is particularly important for leakage management, bulk revenue, and district metering applications. The clear bore of the AquaMaster3 eliminates the possibility of damage by particulate matter. Additionally, the absence of moving and wearing components ensures that this unique level of performance is reliable long term. Accuracy as standard (Â±0.25 % Mains power) or (Â±0.50% battery power) in both forward and reverse flow directions.\u003c\/p\u003e\n\u003ch3\u003eEasy and Quick Commissioning\u003c\/h3\u003e\n\u003cp\u003e'Fit-and-Flow' data storage inside AquaMaster eliminates the need to match sensor and transmitter in the field. On initial installation, the self-configuration sequence automatically replicates into the transmitter all calibration factors, meter size and serial numbers, as well as customer site-specific settings, eliminating the opportunity for error.\u003c\/p\u003e\n\u003ch3\u003eLogged Data Storage\u003c\/h3\u003e\n\u003cp\u003eThe AquaMaster3 transmitter can contain an optional multi-speed, multi-channel, dual-variable logger. The ability of the logger to run at two speeds simultaneously enables the user to investigate, in precise detail, flow and pressure activity during a period of interest. AquaMaster3 eliminates such quantization effects, averaging digitally over the selected logging interval. Such high resolution data facilitates allow step testing, leakage detection and water network analysis.\u003c\/p\u003e\n\u003ch3\u003eUniversal AquaMaster3 Transmitter - Powerful and Flexible\u003c\/h3\u003e\n\u003cp\u003eAquaMaster3 design of mains, renewable energy and battery-powered transmitter. It has a stainless steel housing with a thermoplastic outer and the assembly is sealed-for-life to IP68 as standard. The transmitter incorporates military specification plug \u0026amp; socket connections for all inputs and outputs. The transmitter can be mounted integral with the AquaMaster sensor (integral mount) or remotely from the AquaMaster sensor (remote) to enable the sensor to be buried for example. For integral sensors, the mounting system positions the display so that it is visible from both the top and the side.\u003c\/p\u003e\n\u003ch3\u003eAssured Quality of the AquaMaster3 FET221 Transmitter\u003c\/h3\u003e\n\u003cp\u003eAquaMaster is designed and manufactured in accordance with international quality procedures (\u003ca href=\"https:\/\/www.iso.org\/home.html\" rel=\"nofollow noopener\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e) and all flowmeters are calibrated on nationally-traceable calibration rigs to provide the end-user with complete assurance of both quality and performance of the meter.\u003c\/p\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/08\/ABB-Aquamaster-3-transmitter-for-magmeter-remote-battery-backup-psc-texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-22802 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/08\/ABB-Aquamaster-3-transmitter-for-magmeter-remote-battery-backup-psc-texas-300x300.jpg\" alt=\"ABB-Aquamaster3-transmitter-for-magmeter-remote-battery-backup-psc-texas\" width=\"300\" height=\"300\"\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003eNew and Used Units Available\u003c\/h3\u003e\n\u003cp\u003eOccasionally, demo, return, refurbished, or otherwise used items are made available for purchase on our website at a discount price. All used products are notated as such, and have been recently tested to ensure they power on. All used units are eligible for a full refund in accordance to our \u003ca href=\"https:\/\/psctexas.com\/fulfillment-policy\/#Used\"\u003ereturn policy\u003c\/a\u003e.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45878379937923,"sku":"FET221 (returned)","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/AquaMaster3-Transmitter-ABB-Replacement-MagMeter-Aqua-Master-Process-Solutions-Corp.jpg?v=1763385582"},{"product_id":"optiflux-4400-magmeter","title":"OPTIFLUX 4400 Magmeter","description":"The OPTIFLUX 4400 \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF)\u003c\/a\u003e, or magmeter, arrives in accordance with IEC 61508 for safety-related \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e, up to \u003ca href=\"https:\/\/www.iec.ch\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003esafety integrity level (SIL) 2\/3\u003c\/a\u003e. It features automated partial proof testing capabilities, which allows extension in the time interval between full proof tests while increasing plant uptime in safety instrumented systems (SIS). Aside from safety applications, the OPTIFLUX 4400, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, is particularly suitable for process applications with high accuracy requirements and difficult \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow\u003c\/a\u003e conditions, for example, pulsating and turbulent flow. Due to its wide selection of lining and electrode materials, it's ideal for flow measurement and dosing of chemicals and corrosive liquids such as acids. This magmeter can improve conductivity measurement, and operators can also monitor a defined range of conductivity. The OPTIFLUX 4400 magmeter comes with a wide range of flow and process diagnostics for a high degree of reliability. In addition, it features a best-in-class diagnostic test interval including a fault response time of only two minutes. If running out of spec, this flow meter will issue an alarm to the control room much faster than other EMFs on the market. The OPTICHECK service tool can also provide a full on-site verification of the OPTIFLUX 4400 without process interruption. \u003cimg class=\"alignright wp-image-25341 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/optiflux-4400-krohne-electromagnetic-flowmeter-emf-magmeter-wastewater-flow-psc-texas.png\" alt=\"optiflux-4400-krohne-electromagnetic-flowmeter-emf-magmeter-wastewater-flow-psc-texas\" width=\"1666\" height=\"1066\"\u003e \u003ch3\u003eFeatures of the OPTIFLUX 4400 Magmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eautomated partial proof testing capability for extending full proof test intervals\u003c\/li\u003e \u003cli\u003eintegrated conductivity measurement\u003c\/li\u003e \u003cli\u003eenhanced diagnostic package: \u003cul\u003e \u003cli\u003ecompliant with \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMUR NE 107\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ediagnostic test interval including fault response time of only 2 minutes, it also alerts if meter runs out of spec\u003c\/li\u003e \u003cli\u003edetects gas bubbles, solids, electrode corrosion, deposits on the electrodes, conductivity changes, an empty or partially filled pipe, a flow profile disturbance, external magnetic fields, etc.\u003c\/li\u003e \u003cli\u003eredundant data storage\u003c\/li\u003e \u003cli\u003ereal-time clock for logging events\u003c\/li\u003e \u003cli\u003euser-friendly color display for status indication\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eease of installation and device set-up: \u003cul\u003e \u003cli\u003eoptimized device menu with reduced menu items for quick commissioning\u003c\/li\u003e \u003cli\u003eavailable with \"virtual reference\" option: cost-saving installation without grounding rings (in non-SIL applications)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ehigh measuring accuracy and long-term stability, for example, measuring error of only Â±0.2% of measured value Â±1 mm\/s\u003c\/li\u003e \u003cli\u003ewide range of liner and electrode materials\u003c\/li\u003e \u003cli\u003eapproval for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e: ATEX, IECEx db eb\u003c\/li\u003e \u003cli\u003efield device verification of flowmeter with the OPTICHECK Master and OPTICHECK DTM service tools, e.g. for partial proof test documentation according to \u003ca href=\"https:\/\/www.iec.ch\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIEC 61508\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Magmeter Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eSafety Instrumented Systems (SIL 2\/3)\u003c\/li\u003e \u003cli\u003eapplications with high accuracy requirements\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"3\" DN080","offer_id":45878390456451,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"4\" DN100","offer_id":45878390489219,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"6\" DN150","offer_id":45878390521987,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"8\" DN200","offer_id":45878390554755,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"10\" DN250","offer_id":45878390587523,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/OPTIFLUX-4400-krohne-electromagnetic-flow-meter.png?v=1763385903"},{"product_id":"optiflux-4300-for-sewage-treatment","title":"OPTIFLUX 4300 for Sewage Treatment","description":"\u003cp\u003eThe OPTIFLUX 4300 is an electromagnetic flow meter (EMF), or magmeter, for advanced water processing applications with aggressive liquids or abrasive media. The high-end flow meter is particularly suitable for critical applications requiring high accuracy and many diagnostic functions such as sewage treatment or handling sludge. It enables reliable measurement even under very harsh process conditions with temperatures up to 356˚F, low conductivities (≥1 µS\/cm), high solid contents (up to 70%), and high pressures (up to 1500 bar \/ 21751 psi). For custody transfer applications, the OPTIFLUX 4300, from KROHNE, has a wide range of certifications including OIML R49 and R117 or MI-001 and MI-005. It is also ideal for flow measurement in district heating networks requiring MI-004 approval.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 x 4-20 mA, HART, Modbus, FOUNDATION Fieldbus, Profibus-PA\/DP, PROFINET\u003c\/li\u003e\n\u003cli\u003efor custody transfer: OIML R49, OIML R-117; MI-001, MI-004, MI-005\u003c\/li\u003e\n\u003cli\u003estandard measurement accuracy: ±0.2% or ±1mm\/s of measured value (MV)\u003c\/li\u003e\n\u003cli\u003efor hazardous areas: ATEX, IECEx, NEPSI, FM, CSA, EAC, INMETRO\u003c\/li\u003e\n\u003cli\u003especial designs, sizes, inner diameters and liner thicknesses on request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the OPTIFLUX 4300 for Sewage Treatment*\u003c\/h2\u003e\n\u003cp\u003eThe OPTIFLUX 4300 is available in a wide diameter range up to DN3000 \/ 120\". Its virtual reference option allows for a very cost-saving measuring mode without additional grounding rings – particularly when it comes to large diameters. Installation in measurement chambers subject to (constant) flooding is possible with the IP68 \/ NEMA 6P rated version. The meter is approved for use in hazardous areas and offers various digital communication options. A full on-site verification of the OPTIFLUX 4300 without process interruption can also be carried out using the OPTICHECK service tool.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range; for example, turn down ratio: 1000:1\u003c\/li\u003e\n\u003cli\u003eavailable with virtual reference grounding method, which means grounding rings are not necessary\u003c\/li\u003e\n\u003cli\u003eextensive flowmeter and process diagnostics (including NE 107)\u003c\/li\u003e\n\u003cli\u003ePTFE, PFA, ETFE, hard rubber, soft rubber, PU liner, which offer excellent chemical and abrasion resistance\u003c\/li\u003e\n\u003cli\u003ewide range of electrode materials\u003c\/li\u003e\n\u003cli\u003eoptional external coatings for offshore or subsoil installation (also according to \u003ca href=\"https:\/\/www.iso.org\/standard\/77795.html\" rel=\"nofollow noopener\" target=\"_blank\" title=\"ISO Standards\"\u003eISO 12944\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003efull bore design: no moving parts, no wear, in addition to no pressure loss\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eThe OPTIFLUX 4000 Series\u003c\/h2\u003e\n\u003cp\u003eThe OPTIFLUX 4000 design meets the demands of a very wide range of applications. It also has a field proven and unsurpassed lifetime. This due to the fully welded, full bore pipe construction, absence of moving parts, and wear resistant liner materials. Even for demanding applications, such as in harsh environments or with aggressive and abrasive media, the OPTIFLUX 4000 can offer an ideal solution. For custody transfer applications, OPTIFLUX 4000 has a wide range of certifications such as OIML R49 \u0026amp; R117, MI-001, MI-004, and MI-005.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eCommon Uses of the OPTIFLUX 4300; Sewage Treatment and More\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eadvanced applications with clean, aggressive, or abrasive liquids\u003c\/li\u003e\n\u003cli\u003efor low conductive media (\u0026gt;1 μS\/cm)\u003c\/li\u003e\n\u003cli\u003efiscal metering (custody transfer) of liquids other than water\u003c\/li\u003e\n\u003cli\u003ecustody transfer flow measurement such as in district heating networks\u003c\/li\u003e\n\u003cli\u003eapplications with high pressures (max. 1500 bar)\u003c\/li\u003e\n\u003cli\u003esludge and also sewage treatment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878424666243,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optiflux-4300-magmeter-wastewater-municipal-water-flow-measurement-process-solutions-corp-texas.png?v=1763386442"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/collections\/KROHNE-WATERFLUX-3070-Magnetic-Flow-Meter-Municipal-Waste-Water-Flow-Measurement-MagMeter-Process-Solutions-Corp-PSC-Texas_15e671e6-f8f8-4def-8de4-14a13bb6888f.jpg?v=1771536333","url":"https:\/\/www.psctexas.shop\/collections\/magnetic-flow-meters-magmeters.oembed","provider":"Process Solutions Corp.","version":"1.0","type":"link"}