{"title":"Municipal Instrumentation","description":"","products":[{"product_id":"remote-monitoring-solutions-for-waste-water-treatment-plants","title":"Remote Monitoring Solutions for Waste Water Treatment Plants","description":"\u003cdiv class=\"elementor-element elementor-element-b14c5bf elementor-widget elementor-widget-heading\" data-id=\"b14c5bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-0616790 elementor-widget elementor-widget-woocommerce-product-content\" data-id=\"0616790\" data-element_type=\"widget\" data-widget_type=\"woocommerce-product-content.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003eWe specialize in providing critical asset and process monitoring solutions to wastewater and water treatment plants through the use of wireless cloud computing technology. Our engineers can seamlessly integrate independent processes to communicate directly with your DCS, even in the most remote locations. Thus, our industrial wireless monitoring systems increase operational safety, ensure environmental compliance, and improve productivity and efficiency by process upset.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003enear real-time view of any asset, equipment, or automation process\u003c\/li\u003e\n\u003cli\u003eeasy to retrofit with existing equipment and sensors\u003c\/li\u003e\n\u003cli\u003ebring all operations data back to control room, DCS, PLC, etc.\u003c\/li\u003e\n\u003cli\u003eoptional easy to use and access cloud software with trending data, predictive analysis, and also more including custom programmed functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEasy to Implement Wireless Monitoring Systems to Optimize Process Automation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"alignright wp-image-27553\" src=\"https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?resize=500%2C277\u0026amp;ssl=1\" alt=\"water-wastewater-treatment-plant-remote-monitoring-solutions\" width=\"500\" height=\"277\" srcset=\"https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?resize=300%2C166\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?resize=768%2C425\u0026amp;ssl=1 768w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?resize=600%2C332\u0026amp;ssl=1 600w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?resize=100%2C55\u0026amp;ssl=1 100w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/WWTP-Monitoring-small.jpg?w=1000\u0026amp;ssl=1 1000w\" sizes=\"(max-width: 500px) 100vw, 500px\"\u003e\u003c\/p\u003e\n\u003cp\u003eFurthermore, with our cloud software and remote monitoring transmitters, users can view real trends of data from any device, anywhere in the world. Our wireless monitoring systems are suitable for any application and be customized to fit your exact needs while providing custom software to bring all your data to the cloud in a way that makes sense for you.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eloop-powered or solar options with battery back-up for remote data points\u003c\/li\u003e\n\u003cli\u003ecustomizable alarm options, password protection, and industry-leading security\u003c\/li\u003e\n\u003cli\u003escalable: from transmission of one single data point to the engineering and installation of an entirely new automation system\u003c\/li\u003e\n\u003cli\u003elow-cost: save money by not running copper wires, save money compared to big name brands, save money by effectively prioritizing and managing maintenance plans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"elementor-element elementor-element-feca10f elementor-widget elementor-widget-heading\" data-id=\"feca10f\" data-element_type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMake any Data Point Go Wireless in Your Waste Water Treatment Plant (WWTP)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection class=\"elementor-section elementor-inner-section elementor-element elementor-element-04f42db elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"04f42db\" data-element_type=\"section\" data-settings='{\"_ha_eqh_enable\":false}'\u003e\n\u003cdiv class=\"elementor-container elementor-column-gap-default\"\u003e\n\u003cdiv class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-d17fb62\" data-id=\"d17fb62\" data-element_type=\"column\"\u003e\n\u003cdiv class=\"elementor-widget-wrap elementor-element-populated\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-74dc1f1 elementor-widget elementor-widget-text-editor\" data-id=\"74dc1f1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003eOur industrial remote monitoring systems are assembled in-house here in Houston, Texas in our\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/psctexas.com\/iso-certification\" rel=\"noopener\" target=\"_blank\"\u003eISO certified workshop\u003c\/a\u003e. We offer multiple certifications and approvals, thus ensuring quality and safety for most any application. We supply a wide range of industrial instrumentation and provide engineering support to build entire automation systems with remote control and real-time process monitoring. However, our industrial wireless monitoring solutions are flexible and we can retrofit them into any application, meaning you can save money by using your existing sensor and instrumentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-579709d elementor-widget elementor-widget-text-editor\" data-id=\"579709d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cul\u003e\n\u003cli\u003epressure, temperature, level, and flow\u003c\/li\u003e\n\u003cli\u003eGPS tracking\u003c\/li\u003e\n\u003cli\u003egas detection\u003c\/li\u003e\n\u003cli\u003ebrake and tire monitoring\u003c\/li\u003e\n\u003cli\u003ecameras\u003c\/li\u003e\n\u003cli\u003ecommunication via Ethernet protocols,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/mqtt-sparkplug-for-mqtt-protocol\/\"\u003eMQTT\u003c\/a\u003e, cellular, LoRaWAN,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/modbus.org\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus\u003c\/a\u003e, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003ch3\u003eRemote Monitoring of Waste Water Treatment Plants via Cloud Software\u003c\/h3\u003e\n\u003cp\u003eWith our intelligent process insight, operators gain an unprecedented look into their water treatment processes. Furthermore, our technology connects even the most remote signals and brings them straight to the control room. Going beyond the basics, your data can also integrate into our sophisticated Cloud Computing software. We develop our software in-house and can provide a completely custom program that brings all your data to one place and presents it in a way that is actually useful and meaningful.\u003c\/p\u003e\n\u003cp\u003eOur Cloud Solutions give you smart insight into your processes as well as asset performance. This will help you make informed decisions to increase safety and prioritize maintenance in addition to improving processes and much more. We provide insight on near real-time data for numerous data points for example, temperature, pressure, flow, level, gas detection, water quality, and much more.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?ssl=1\"\u003e\u003cimg loading=\"lazy\" data-recalc-dims=\"1\" decoding=\"async\" class=\"alignright wp-image-27554\" src=\"https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring.jpg?resize=500%2C284\u0026amp;ssl=1\" alt=\"Continuous-Effluent-Monitoring-remote-monitoring-solutions-for-wastewater-monitoring-water-treatment-plants\" width=\"500\" height=\"284\" srcset=\"https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=300%2C171\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=1024%2C582\u0026amp;ssl=1 1024w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=768%2C437\u0026amp;ssl=1 768w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=1536%2C874\u0026amp;ssl=1 1536w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=2048%2C1165\u0026amp;ssl=1 2048w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=1200%2C683\u0026amp;ssl=1 1200w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=1980%2C1126\u0026amp;ssl=1 1980w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=600%2C341\u0026amp;ssl=1 600w, https:\/\/i0.wp.com\/psctexas.com\/wp-content\/uploads\/2025\/03\/Continuous-Effluent-Monitoring-scaled.jpg?resize=100%2C57\u0026amp;ssl=1 100w\" sizes=\"(max-width: 500px) 100vw, 500px\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications that Benefit from Industrial Wireless Monitoring Systems\u003c\/h3\u003e\n\u003cul id=\"GCM\"\u003e\n\u003cli\u003etank level monitoring\u003c\/li\u003e\n\u003cli\u003elift stations\u003c\/li\u003e\n\u003cli\u003ewater recycling and purification\u003c\/li\u003e\n\u003cli\u003ecooling towers\u003c\/li\u003e\n\u003cli\u003eoverall monitoring of wastewater treatment plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45592080908419,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/WWTP-Monitoring-wastewater-remote-monitoring-process-solutions-corp-temp.webp?v=1755603061"},{"product_id":"waterflux-3070-battery-powered-magmeter","title":"WATERFLUX 3070, Battery Powered Magmeter","description":"\u003cp\u003eThe WATERFLUX 3070 is a battery powered magmeter, or electromagnetic water meter, for use in water and wastewater applications such as in water abstraction wells, district metering areas (DMA), and custody transfer measurement of potable water (MI-001, OIML R49). With optional pressure and temperature sensors, this magmeter can also be of use in leak detection, quality control, and pressure management systems.\u003c\/p\u003e\n\u003cp\u003eUnlike mechanical water meters, the WATERFLUX 3070, from KROHNE, is maintenance-free and offers a much larger turn down ratio (1000:1). Its measuring tube, with a rectangular and reduced cross-section, enables a stable measurement even at low flow rates. Due to the optimization of the flow profile, the WATERFLUX 3070 can install virtually anywhere without straight inlet or outlet runs. For example, it functions behind pipe bends, slide valves, or near a reduction in the pipe. Furthermore, burial installation options or use in areas that frequently flood is available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eintegrated temperature and pressure measurement for leak monitoring\u003c\/li\u003e\n\u003cli\u003ecustody transfer: MI-001, OIML R49 up to DN600 \/ 24 inches\u003c\/li\u003e\n\u003cli\u003eno inlet \/ outlet runs requirements\u003c\/li\u003e\n\u003cli\u003ewith custody transfer approval for heat meter applications (MID MI-004)\u003c\/li\u003e\n\u003cli\u003ecompact or field mount versions available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the WATERFLUX 3070 Battery Powered Magmeter*\u003c\/h2\u003e\n\u003cp\u003eThis magmeter is available for battery-powered operation with integrated batteries or optional external battery pack (PowerBlock). However, the WATERFLUX 3070 offers multiple power supply options. For locations with mains power supply, an optional FlexPower unit is available to connect the battery powered magmeter to a 110-230V AC or 10-30V DC power source on site. For example, it can receive power from an electrical grid, a solar panel, or a small windmill.\u003c\/p\u003e\n\u003cp\u003eWhen a permanent transmission of multi-parameter measurement readings, such as flow, pressure, or temperature is desirable, \u003ca title=\"Modbus Protocol\" href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e communication is available as a simple interface. For remote or difficult to access measurement points, such as abstraction wells, the water meter can use a GPRS or 3G module for remote transmission of readings. Furthermore, the OPTICHECK service tool can provide a full on-site verification of the WATERFLUX 3070 without process interruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e\n\u003cli\u003eunique rectangular sensor design for good low flow performance\u003c\/li\u003e\n\u003cli\u003eavailable with patent virtual reference electrode, so no grounding rings are necessary\u003c\/li\u003e\n\u003cli\u003ehigh accuracy at peak flows during the day and at low flows during the night\u003c\/li\u003e\n\u003cli\u003esensor tube with \u003ca title=\"Arkema - Rilsan Coating\" href=\"https:\/\/www.arkema.com\/usa\/en\/product\/technicalpolymers\/rilsan-family-products\/rilsan-pa11\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eRilsan coating\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e\n\u003cli\u003esuitable for immersion in flood chambers\u003c\/li\u003e\n\u003cli\u003ebattery powered magmeter for remote locations or mains powered with battery backup\u003c\/li\u003e\n\u003cli\u003eFlexPower option for power connection to electrical grid, solar panel, or windmill\u003c\/li\u003e\n\u003cli\u003eunique low power Modbus option for battery powered magmeter version\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eUnique Rectangular Design\u003c\/h2\u003e\n\u003cp\u003eThe strengths of the WATERFLUX 3000 Series lies in its unique construction with a rectangular cross section and its efficient coil construction. The coils provide a stronger and more homogeneous magnetic field, leading signal to noise ratio improvements. The measurement, therefore, is independent of the flow profile, so measurements are very stable. This results in a very good low flow performance with a minimal pressure drop and a minimal impact on the pressure strategy of the network.\u003c\/p\u003e\n\u003cp\u003eBecause of the unique WATERFLUX 3000 flow sensor design, whereby the mean flow velocity and flow profile are optimized within the rectangular and reduced cross-section, the additional uncertainty for upstream disturbances is drastically reduced. The water meter can install directly behind an elbow or reducer in the pipe without a straight inlet or outlet lengths. A substantial reduction of the inlet and outlet section requirements offers the option to reduce the size of the measurement pits. The Rilsan coating of the flow sensor is chemically resistant, durable, and maintenance-free. In addition, the coating is flexible and tough, smooth and pore-free, and free of solvents. The coating is in wide use in the water industry and offers a wide range of drinking water certifications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eCommon Applications for a Battery Powered Magmeter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater and wastewater applications\u003c\/li\u003e\n\u003cli\u003eremote monitoring of water supplies and distribution networks\u003c\/li\u003e\n\u003cli\u003ewater consumption and fiscal metering (custody transfer)\u003c\/li\u003e\n\u003cli\u003eirrigation and abstraction\u003c\/li\u003e\n\u003cli\u003ewater treatment\u003c\/li\u003e\n\u003cli\u003ereplacement of mechanical turbine meters\u003c\/li\u003e\n\u003cli\u003eleak detection\u003c\/li\u003e\n\u003cli\u003echecking of pumps and water wells\u003c\/li\u003e\n\u003cli\u003ecustody transfer flow measurement in district heating networks\u003c\/li\u003e\n\u003cli\u003emeasurement of potable water\u003c\/li\u003e\n\u003cli\u003emeasurement of raw water\u003c\/li\u003e\n\u003cli\u003eoutlet of water purification plants\u003c\/li\u003e\n\u003cli\u003emonitoring distribution networks\u003c\/li\u003e\n\u003cli\u003ewater consumption as well as billing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878360539267,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-waterflux-3070-battery-powered-magmeter-municipal-water-utility-wastewater-treatment-water-flow-measurement-psc-texas.png?v=1763385094"},{"product_id":"psc-lift-station-meter","title":"PSC Lift Station Meter","description":"The PSC Lift Station Meter is designed and built in-house at Process Solutions Corp. This integrated system is ideal for wastewater lift stations to automate switching activities and provide real-time status updates. \u003ch3 style=\"text-align: left;\"\u003eFeatures of the PSC Lift Station Meter\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-27412\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/psc-lift-station-meter-automate-switching-wastewater-treatment-plant-process-solutions-corp-texas-240x300.jpg\" alt=\"psc-lift-station-meter-automate-switching-wastewater-treatment-plant-process-solutions-corp-texas\" width=\"400\" height=\"500\"\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eWater-proof \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eNEMA 4X\u003c\/a\u003e Hoffman enclosure with cutouts\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ecellular modem\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eWiFi hotspot capability\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e100 to 480VAC 50\/60 HZ input power flexibility\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e12VDC battery backup with flexible capacity\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eAC input power failure reporting capability\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e7 pump status monitoring inputs\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eFTP accessible via wireless or Ethernet cable CSV log file data logs that contain pump on\/off times\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eremovable 2GB micro SD card for data logs\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ePC program available for a final report generation\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003etouchscreen for viewing current status of pumps\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eweb interface capability for remote monitoring\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eemail alerting capability\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus over Ethernet\u003c\/a\u003e or serial RS232\/485 capable for interfacing to other devices\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e6 relay outputs available\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e4 analog inputs available for 4-20mA or 0 to 10VDC measurements\u003c\/li\u003e \u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878361849987,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/lift-station-meter-process-solutions-corp-automated-lift-station-meter-psc-texas-square_ed81edaa-b4f5-4d88-96b3-dbd31d9ae2f9.png?v=1763385108"},{"product_id":"tidalflux-2300-magmeter-for-partially-filled-pipes","title":"TIDALFLUX 2300, Magmeter for Partially Filled Pipes","description":"\u003cp\u003eThe TIDALFLUX 2300 is an electromagnetic flow meter (EMF), or magmeter, with patented, capacitive level measurement for use in partially filled pipes (up to DN1600 \/ 64 inches). This magmeter is the ideal solution for flow measurement of municipal or industrial wastewater in pressureless transport lines. However, this magnetic flow meter is also suitable for measurement of effluent brine from seawater and well water injection applications. Unlike open channel systems (Venturi, V-notches etc.) these inline flow meters are a closed measuring solution without obstructions. In addition, these magmeters offer a much better accuracy at lower total costs of ownership.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eintegrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)\u003c\/li\u003e\n\u003cli\u003eelectrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface\u003c\/li\u003e\n\u003cli\u003e220\/110 V or 24 VDC power supply\u003c\/li\u003e\n\u003cli\u003eaccurate (±1%) and cost-saving alternative to open channel systems\u003c\/li\u003e\n\u003cli\u003eflange: DN200 to DN1600 \/ 8 to 64 inches\n\u003cul\u003e\n\u003cli\u003evarious flange standards like DIN, ANSI and JIS\u003c\/li\u003e\n\u003cli\u003epolyurethane liner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 x 4-20 mA, pulse, HART, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus\u003c\/a\u003e, as well as \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.profibus.com\" target=\"_blank\" title=\"PROFINET Protocol\"\u003ePROFINET\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the TIDALFLUX 2300 Magmeter for Partially Filled Pipes*\u003c\/h2\u003e\n\u003cp\u003eThe measuring tube of the TIDALFLUX 2300, from KROHNE, comes with a polyurethane (PUR) liner for abrasion and chemical resistance. Its smooth surface prevents build-up of fat and other deposits which minimizes the need for regular cleaning. For direct burial installation or applications in areas that can be partially flooded, this flow meter can also offer IP68 \/NEMA 6P versions. Due to the presence of flammable hydrogen sulphide (H\u003csmall\u003e2\u003c\/small\u003eS) in many wastewater applications, this magmeter also has ATEX \/ IECEx zone 1 approval. Furthermore, the TIDALFLUX 2300 comes with extensive diagnostics. In addition, the OPTICHECK service tool can carry out full on-site verification of these flow meters without process interruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e\n\u003cli\u003eclosed measurement solution with patented integrated non-contact level measurement\u003c\/li\u003e\n\u003cli\u003efor effluent and slurries in gravity pipelines \/ sewers\u003c\/li\u003e\n\u003cli\u003echemically and also abrasion resistant PUR liner\u003c\/li\u003e\n\u003cli\u003eaccuracy: ±1% of measured value (MV)\u003c\/li\u003e\n\u003cli\u003eelectrodes not in contact with floating deposits\u003c\/li\u003e\n\u003cli\u003eoptional version for direct burial installation and flooded areas (\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP68\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003estandard factory calibration, also no on-site calibration requirements\u003c\/li\u003e\n\u003cli\u003eextensive flow meter and process diagnostics, which exceed the NE 107 requirement\u003c\/li\u003e\n\u003cli\u003ealso for use in hazardous areas zone 1: ATEX, IECx Zone 1, Class 1 Div 2\u003c\/li\u003e\n\u003cli\u003eon-site verification of flow meter with OPTICHECK service tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eCommon Applications of this Magmeter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater and wastewater applications in partially filled and gravity feed pipes\u003c\/li\u003e\n\u003cli\u003ecost-effective replacement of expensive siphon tube constructions\u003c\/li\u003e\n\u003cli\u003esurface water flow measurement\u003c\/li\u003e\n\u003cli\u003ebiological and also chemical wastewater\u003c\/li\u003e\n\u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e\n\u003cli\u003ecombined sewer overflows (CSOs)\u003c\/li\u003e\n\u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e\n\u003cli\u003erainwater retention basins\u003c\/li\u003e\n\u003cli\u003einfluent \/ intake as well as effluent at wastewater treatment plants\u003c\/li\u003e\n\u003cli\u003edischarge to surface water\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363750531,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/krohne-tidalflux-2300-magmeter-for-partially-filled-pipes-flow-measurement-electromagnetic-flow-meter-process-solutions-corp_42b2897a-4911-4e0f-be7b-b6b63ece52df.png?v=1763385143"},{"product_id":"af-e-400-magmeter-for-chemical-dosing","title":"AF-E 400 Magmeter for Chemical Dosing","description":"Compact, robust, reliable, and cost-effective: these are important characteristics of instrumentation in industrial automation. The AF-E 400 is the culmination of \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e expertise in a best-in-class \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter, or magmeter\u003c\/a\u003e. Its unique \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact sensor design\u003c\/a\u003e makes it ideal for use in tight spaces and for parallel installations in a variety of conductive liquid applications such as chemical dosing. The reliable round bore reduction limits pressure drops and ensures strength and accuracy under pressure. Furthermore, the cost-effective integrated temperature measurement eliminates the need for an additional temperature measurement device. \u003cul\u003e \u003cli\u003enarrow installation width\u003c\/li\u003e \u003cli\u003ehigh-temperature capability\u003c\/li\u003e \u003cli\u003eintegrated temperature sensor\u003c\/li\u003e \u003cli\u003emulti-IO-link, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, or double analog output option\u003c\/li\u003e \u003cli\u003ehighest flow and low absolute uncertainty per diameter\u003c\/li\u003e \u003cli\u003evarious threaded connections directly on the device (no adapters needed)\u003c\/li\u003e \u003c\/ul\u003e \u003cimg class=\"alignright wp-image-25531 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/krohne-af-e-400-magmeter-for-chemical-dosing-compact-magnetic-flow-meter-process-solutions-corp.jpg\" alt=\"krohne-af-e-400-magmeter-for-chemical-dosing-compact-magnetic-flow-meter-process-solutions-corp\" width=\"750\" height=\"553\"\u003e \u003ch3 style=\"text-align: left;\"\u003eAF-E 400 Magmeter for Chemical Dosing\u003c\/h3\u003e The AF-E 400 is an electromagnetic flow meter for \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003eutility applications\u003c\/a\u003e such as flow monitoring in sludge treatment processes. This ultra-compact magmeter is the ideal choice for applications with conductive liquids in tight spaces such as on chemical dosing skids. It features best-in-class accuracy in every flow range, thus allowing optimal processing in automation. The round bore reduction of the sensor makes this \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e more resilient in terms of increased pressure, while ensuring high accuracy over a wide pressure and temperature range. Its integrated temperature measurement eliminates the need for an additional sensor. The AF-E 400 guarantees maximum flexibility when it comes to installation. Due to the special design of its magnetic circuit, field strength, and electronics, this magmeter can install in extreme proximity to one another (as close as 2 mm \/ 0.08\"). Thus, it can mount in parallel without interference. Furthermore, this electromagnetic flow meter offers various output and communication options. Among others, the device features an IO-Link and a Modbus option to provide operators with multiple sensor and application data. IO-Link also enables faster sensor installation or replacement. \u003ch3 style=\"text-align: left;\"\u003eFeatures of the AF-E 400 Magmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003emeasurement of flow rate, totalized flow, and temperature - up to 194ËF (90ËC)\u003c\/li\u003e \u003cli\u003erobust casted stainless steel housing (2 mm \/ 0.08\" thickness)\u003c\/li\u003e \u003cli\u003emaintains accuracy over a wide pressure and temperature range\u003c\/li\u003e \u003cli\u003eround bore tube for minimal pressure loss and a high turndown ratio without risk of cavitation\u003c\/li\u003e \u003cli\u003eno cross talk: allows installation in series or in parallel up to a distance of 2 mm \/ 0.08\" from device to device\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMURÂ NEÂ 107\u003c\/a\u003e diagnostics\u003c\/li\u003e \u003cli\u003eIO-Link enables transmission of more process data and automatic device configuration without programming\u003c\/li\u003e \u003cli\u003erotatable full color display\u003c\/li\u003e \u003cli\u003enominal sensor sizes 6, 15, 20, 25 mm for flow rates up to 150 l\/min with G (male) and also NPT or RC (female) threads \u003cul\u003e \u003cli\u003evarious adapters for other thread types available\u003c\/li\u003e \u003cli\u003eadapter solution for 40 and 50 mm for flow rates up to 500 l\/min\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3 style=\"text-align: left;\"\u003eCommon Applications for the AF-E 400 Magmeter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eflow measurement of conductive liquids in utility applications\u003c\/li\u003e \u003cli\u003eflow monitoring in recirculation of hot as well as cold water\u003c\/li\u003e \u003cli\u003edosing skids for reagents and catalysts or chemicals\u003c\/li\u003e \u003cli\u003eflow monitoring in sludge treatment processes\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363783299,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-AFE-400-electro-magnetic-flow-measurement-magmeter-process-solutions-texas_9731a2a3-2370-48d4-a140-71c0ec20184f.png?v=1763385145"},{"product_id":"dk32-rotameter-va-meter","title":"DK32 Rotameter (VA Meter)","description":"The DK32 is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/variable-area\/\"\u003evariable area flow meter (VA meter)\u003c\/a\u003e, also known as a rotameter or purge meter, is ideal for measuring \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003elow flow rates of liquids and gases\u003c\/a\u003e. This durable flow meter is particularly suitable for flow monitoring and dosing chemicals in the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal water and wastewater industry\u003c\/a\u003e. Due to its robust all-metal design, the DK32, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, is also ideal for difficult process conditions with temperatures up to 392ËF (200ËC) or pressures up to 400 barg (5800 psig). Furthermore, it is available with a metering valve as standard to accurately set the flow value. \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eunlike the \u003ca href=\"https:\/\/psctexas.com\/product\/dk34-va-meter-rotameter\/\"\u003eDK34\u003c\/a\u003e, the DK32 features top\/bottom valve in addition to rear process connection\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003enarrow, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact design\u003c\/a\u003e enabling a high packing density\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eeasy installation and commissioning\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ehigh resistance to pressure and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esturdy metal design: stainless steel or alloy\u003c\/li\u003e \u003c\/ul\u003e The DK32 rotameter can operate without auxiliary power supply. Furthermore, it features a local indication with optional minimum\/maximum limit switches (\u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMUR\u003c\/a\u003e), a reed contact, or analog output (4-20 mA or \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e). To provide constant flow rates, in case of variable inlet or outlet pressures, this VA meter is also available with flow regulators. This rotameter comes with horizontal or vertical process connections for NPT or G thread, flange adapters, as well as many other connection options. The DK32 variable area meter has various approvals for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e and is suitable for use in \u003ca href=\"https:\/\/www.ul.com\/services\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSafety Instrumented Systems (SIL applications)\u003c\/a\u003e. \u003ch3\u003eFeatures of the DK32 Rotameter*\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-25923 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/KROHNE-DK32-Rotameter-Purge-VA-Meter-Waste-Water-Chemical-Dosing-PSC-Texas.jpg\" alt=\"KROHNE-DK32-Rotameter-Purge-VA-Meter-Waste-Water-Chemical-Dosing-PSC-Texas\" width=\"750\" height=\"328\"\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003esimple, low-cost installation: able to measure and display without auxiliary power supply\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003erotameter (purge meter) with 2 optional limit switches for flow monitoring\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003evarious stainless steel and alloy sensor materials\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eoptional surface passivation with \u003ca href=\"https:\/\/www.silcotek.com\/coatings\/silconert\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSilcoNert 2000\u003c\/a\u003e for trace-level analysis\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65\/66 ratings\u003c\/a\u003e\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003efull scale value for liquids: 0.4 to 40 GPH (1.6 to 150 l\/h)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003efull scale value for gases: 0.6 to 170 SCFH (16 to 4,800 l\/h)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eturndown ratio 10:1\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003emaximum measuring error: Â±4% (according to VDI\/VDE 3513-2) as well as Â±3% of full scale\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esuitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eapproved for hazardous areas\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/variable-area\/\"\u003eCommon Uses of a Rotameter\u003c\/a\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edosing of chemical additives such as foam inhibitors, emulsifiers, flocculants, etc.\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eheating as well as cooling water\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esample flow monitoring\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003egas sparging in liquids\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003einjection skids\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003ecooling water\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003edry-run prevention of pumps\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363816067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-dk32-rotameter-variable-area-flow-meter-purge-meter-low-flow-liquid-dosing-process-solutions-corp_b499b9a8-cd5d-4a33-80c6-eeda963aa70a.png?v=1763385146"},{"product_id":"optiflex-1100-guided-radar-level-transmitter","title":"OPTIFLEX 1100 Guided Radar Level Transmitter","description":"The OPTIFLEX 1100 is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/level-transmitters\/guided-radar-tdr\/\"\u003eguided radar level transmitter\u003c\/a\u003e that relies on Time Domain Reflectometry (TDR) technology. It is ideal for \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ebasic municipal water and wastewater storage applications\u003c\/a\u003e in non-hazardous areas. The OPTIFLEX 1100 \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/level-transmitters\/\"\u003elevel transmitter\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, features a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact design\u003c\/a\u003e and is a higher performing replacement for traditional \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/\"\u003elevel instrumentation\u003c\/a\u003e such as RF capacitance as well as conductive level transmitters. \u003cul\u003e \u003cli\u003e2-wire loop-powered level meter for liquids as well as solids\u003c\/li\u003e \u003cli\u003efor general-purpose applications (\u003ca href=\"https:\/\/www.ul.com\/services\/ul-and-c-ul-hazardous-areas-certification-north-america\" target=\"_blank\" rel=\"nofollow noopener\"\u003enon-hazardous areas\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003emeasuring range for liquids: up to 65.6 feet (20 meters)\u003c\/li\u003e \u003cli\u003emeasuring range for solids: 32.8 feet (10 meters)\u003c\/li\u003e \u003cli\u003eeasy menu navigation without opening the housing\u003c\/li\u003e \u003cli\u003eprobes and also process connections are made of stainless steel\u003c\/li\u003e \u003cli\u003efor process temperatures up to 210ËF (100ËC) and pressures up to 16 barg (232 psig)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLevel Measurement of Liquids\u003c\/h5\u003e The OPTIFLEX 1100 guided radar level transmitter can measure the level of a wide range of liquids on a variety of installations within the stated pressure as well as temperature range. It does not require any calibration, so it is only necessary to adapt the probe length and do a short configuration procedure. \u003ch5\u003eLevel Measurement of Solids\u003c\/h5\u003e This level transmitter has a Ã4 mm \/ 0.15\" single cable probe for measuring powders in addition toÂ granulates in silos up to 32.8 feet (10 meters) high. It does not require any calibration, therefore it is only necessary to adapt the probe length and do a short configuration procedure. \u003cimg class=\"alignright wp-image-25916 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/04\/KROHNE-optiflex-1100-Guided-Radar-Level-Transmitter-Water-Utilities-Wastewater-Process-Solutions-Texas.jpg\" alt=\"KROHNE-optiflex-1100-Guided-Radar-Level-Transmitter-Water-Utilities-Wastewater-Process-Solutions-Texas\" width=\"530\" height=\"750\"\u003e \u003ch5\u003eVolume Measurement\u003c\/h5\u003e A strapping table function is available in the configuration menu for volume measurement. Up to 30 volume values can be related to level values. For example: \u003cul\u003e \u003cli\u003eLevel 1= 2 meters \/ Volume 1= e.g. 0.7 m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eLevel 2= 10 meters \/ Volume 2= e.g. 5 m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eLevel 3= 20 meters \/ Volume 3= e.g. 17 m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e \u003c\/ul\u003e This data permits the device to calculate volumes between strapping table entries. \u003ch3\u003eFeatures of the OPTIFLEX 1100 Level Transmitter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ethree types of probes that can all be shortened on site\u003c\/li\u003e \u003cli\u003eability to remove the converter under process conditions as well as 360Ë rotation make the display screen easy to read\u003c\/li\u003e \u003cli\u003edisplay keypad buttons are directly accessible without opening the housing cover\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/level-transmitters\/guided-radar-tdr\/\"\u003eGuided Radar Level Transmitters\u003c\/a\u003e\n\u003c\/h3\u003e \u003cul\u003e \u003cli\u003estorage and simple process applications in non-hazardous areas\u003c\/li\u003e \u003cli\u003eapplications involving basins, ports, in addition to locks\u003c\/li\u003e \u003cli\u003egeneral use in municipal water and wastewater industry\u003c\/li\u003e \u003cli\u003ewater in storage or recycling tanks, basins, etc.\u003c\/li\u003e \u003cli\u003epump control and overfill protection in sludge tanks of wastewater plants\u003c\/li\u003e \u003cli\u003elevel measurement in buffer tanks, collectors, and simple process applications\u003c\/li\u003e \u003cli\u003esilo level monitoring\u003c\/li\u003e \u003cli\u003evolume measurement for storage tanks (with a 30-point strapping table)\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363848835,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optiflex-1100-Guided-Radar-Level-Transmitter-Water-Wastewater-Process-Solutions-Corp-Texas_22f4ca94-81e3-427c-ba72-d773a02efdb0.png?v=1763385147"},{"product_id":"optiflux-2300-flow-meter-for-water","title":"OPTIFLUX 2300, Flow Meter for Water","description":"The OPTIFLUX 2300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, for all demanding \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e. This high-end \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e for water is particularly suitable for municipal water as well as wastewater applications that require high accuracy and extensive diagnostics. The OPTIFLUX 2300 magmeter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, has the widest diameter range available in the market: DN25 to DN3000 (1 to 120\"). In addition, it complies with requirements for custody transfer (MID MI-001, OIML R49). This flow meter also allows for custody transfer measurement without inlet\/outlet runs (0D\/0D) according to OIML R49 accuracy class 1. Furthermore, it offers a wide range of approvals for potable water. Overall, the OPTIFLUX 2300 is an effective alternative to mechanical water meters, not least in custody transfer measurement of potable water. \u003cimg class=\"alignright wp-image-25901 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2300-Magmeter-Flow-Meter-for-Water-Wastewater-Municipal-Water-Flow-Meters-PSC-Texas\" width=\"630\" height=\"740\"\u003e \u003cul\u003e \u003cli\u003e0D\/0D installation according to MID MI-001 and OIML R49 accuracy class 1\u003c\/li\u003e \u003cli\u003eflange: DN25 to DN3000 (1 to 120\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, as well as PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.2% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003emeets potable water standards: ACS, DVGW, NSF, TZW, KTW, WRAS, KIWA, etc.\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2300 also features a \"virtual reference\" option, which allows for a measuring mode without the need of additional grounding rings. This feature enables substantial cost savings in terms of installation and procurement. Installation in measurement chambers, which are subject to (constant) flooding, is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. Moreover, the OPTIFLUX 2300 offers various digital communication options, making it a flexible option for many processes. In addition, operators can carry out a full on-site verification of this flow meter for water without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2300 Magnetic Flow Meter for Water*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turn down ratio: up to 1000:1)\u003c\/li\u003e \u003cli\u003eno inlet\/outlet run requirements for OIML R49 class 1 accuracy\u003c\/li\u003e \u003cli\u003ewidest diameter range available in the market\u003c\/li\u003e \u003cli\u003eavailable with patent virtual reference grounding method, which provides cost-saving installation without grounding rings\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner for excellent chemical resistance\u003c\/li\u003e \u003cli\u003eoptions for burial installation and constant flooding (IP68)\u003c\/li\u003e \u003cli\u003elargest diameter range with custody transfer approval\u003c\/li\u003e \u003cli\u003etamper proof\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003eon-site verification of this flow meter for water with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of this Flow Meter for Water Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral as well as advanced municipal water and wastewater applications\u003c\/li\u003e \u003cli\u003ecustody transfer measurement\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer) of potable water\u003c\/li\u003e \u003cli\u003eabstraction as well as irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater treatment plants such as raw water, drinking water, treatment chemicals, and more\u003c\/li\u003e \u003cli\u003ewastewater networks\u003c\/li\u003e \u003cli\u003ecombined and separate sewage systems\u003c\/li\u003e \u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e \u003cli\u003emunicipal wastewater treatment plants\u003c\/li\u003e \u003cli\u003edesalination plants such as for sea water, permeate, brine, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363881603,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2000-Series-Electromagnetic-Flow-Meter-for-Municipal-Water-Magmeter-Process-Solutions-Texas_3ea1af8f-ab42-4515-85e7-a271b6792bb4.png?v=1763385149"},{"product_id":"optisound-3010-ultrasonic-level-transmitter","title":"OPTISOUND 3010 Ultrasonic Level Transmitter","description":"The OPTISOUND 3010 is a 2-wire or 4-wire \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/level-transmitters\/ultrasonic-level-transmitters\/\"\u003eultrasonic level transmitter\u003c\/a\u003e for \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal water and wastewater\u003c\/a\u003e up to 16.4 feet (5 meters). It is ideal for the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/\"\u003econtinuous level measurement\u003c\/a\u003e of liquids such as rainwater and wastewater as well as bulk solids in the municipal and wastewater industry. The OPTISOUND 3010 level transmitter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, is particularly suitable for use in small tanks or in open channels for \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e. \u003ch3\u003eFeatures of the OPTISOUND 3010 Ultrasonic Level Transmitter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003econtinuous, non-contact \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/\"\u003elevel measurement\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003emaintenance free operation\u003c\/li\u003e \u003cli\u003emeasures independent of varying medium characteristics\u003c\/li\u003e \u003cli\u003esuitable for profile measurement on conveyor belts\u003c\/li\u003e \u003cli\u003esuitable for use in corrosive environments\u003c\/li\u003e \u003cli\u003ealso available with optional mounting bracket for easy alignment of the sensor\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eHow \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/level-transmitters\/ultrasonic-level-transmitters\/\"\u003eUltrasonic Transmitters\u003c\/a\u003e Work\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-25913 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-optisound-3010-Ultrasonic-Level-Transmitter-PSC-Texas.png\" alt=\"KROHNE-optisound-3010-Ultrasonic-Level-Transmitter-PSC-Texas\" width=\"456\" height=\"750\"\u003eThe transducer emits short ultrasonic pulses in the range of 35 kHz to 70 kHz towards the product surface. There, they reflect and then are received by the transducer. The pulses travel at the speed of sound. So, the time elapse from emission to reception of the signals depends on the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/level-water-treatment\/\"\u003elevel in the vessel\u003c\/a\u003e. The latest microcomputer technology and the proven processing software select the level echo from among any number of false echoes and also calculate the exact distance to the product surface. An integrated temperature sensor detects the temperature in the vessel and compensates for the influence of temperature on the signal running time. By simply entering the vessel dimensions, a level-proportional signal generates from the distance. Thus, it is not necessary to fill the vessel for adjustment. \u003ch3\u003eCommon Uses of Ultrasonic Level Transmitters\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eopen basins, channels, sumps, and sludge containers\u003c\/li\u003e \u003cli\u003emunicipal water and wastewater basins\u003c\/li\u003e \u003cli\u003eopen channels for flow measurement\u003c\/li\u003e \u003cli\u003eprofile measurement on conveyor belts\u003c\/li\u003e \u003cli\u003esmall silos and storage tanks for solids\u003c\/li\u003e \u003cli\u003esmall storage tanks with slightly corrosive acids\u003c\/li\u003e \u003cli\u003eapplications with hazardous areas as well as \u003ca href=\"https:\/\/www.ul.com\/services\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSIL\u003c\/a\u003e requirements\u003c\/li\u003e \u003cli\u003elevel measurement during processing and storage of liquids\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878363979907,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optisound-3010-Ultrasonic-Level-Transmitter-Process-Solutions-Corp.png?v=1763385152"},{"product_id":"optiflux-2100-electromagnetic-flowmeter","title":"OPTIFLUX 2100, Electromagnetic Flowmeter","description":"The OPTIFLUX 2100 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flowmeter (EMF), or magmeter\u003c\/a\u003e, for standard \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e. It is the ideal solution for all general \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow applications\u003c\/a\u003e where reliable flow measurement with sufficient yet not extremely high accuracy is necessary. Furthermore, installation in measurement chambers subject to (constant) flooding is possible with the remote \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rated version\u003c\/a\u003e. Its wear resistant liner materials, as well as its full bore design without moving parts, make the OPTIFLUX 2100, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, an effective replacement of mechanical water meters in drinking water distribution networks. Moreover, this electromagnetic flowmeter features a wide range of approvals necessary for potable water measurement. In addition, a full on-site verification of the meter without process interruption can be carried out using the OPTICHECK service tool. \u003cimg class=\"alignright wp-image-25480 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/KROHNE-OPTIFLUX-2100-magmeter-water-flow-measurement-wastewater-treatment-process-solutions-corp-texas.jpg\" alt=\"KROHNE-OPTIFLUX-2100-electromagnetic-flowmeter-magmeter-water-flow-measurement-wastewater-treatment-process-solutions-corp-texas\" width=\"632\" height=\"750\"\u003e \u003ch3 style=\"text-align: left;\"\u003eFeatures of the OPTIFLUX 2100 Electromagnetic Flowmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e \u003cli\u003eoptions for subsoil installation and constant flooding\u003c\/li\u003e \u003cli\u003eproven and unsurpassed life time, huge installed base\u003c\/li\u003e \u003cli\u003estandard wet calibration\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner, which is suitable for low concentrated chemicals\u003c\/li\u003e \u003cli\u003etamper-proof\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.3% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003ediagnostic capabilities, for example: conductivity, electrode error, ambient and process temperature, etc.\u003c\/li\u003e \u003cli\u003efull bore design with no moving parts, no wear, and also no pressure loss\u003c\/li\u003e \u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e \u003cli\u003esuitable for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e such as \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eATEX\u003c\/a\u003e, \u003ca href=\"https:\/\/www.iecex.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIECEx\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fmapprovals.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e, \u003ca href=\"https:\/\/www.csagroup.org\/testing-certification\/certification\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eon-site verification of flowmeter with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3 style=\"text-align: left;\"\u003eCommon Uses of the OPTIFLUX 2100 from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e\n\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eall standard \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eabstraction and irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater treatment plants, for example: raw water, drinking water, treatment chemicals, etc.\u003c\/li\u003e \u003cli\u003ewastewater networks\u003c\/li\u003e \u003cli\u003ecombined and separate sewage systems and sludge\u003c\/li\u003e \u003cli\u003estorm water overflows (SWOs)\u003c\/li\u003e \u003cli\u003emunicipal wastewater treatment plants\u003c\/li\u003e \u003cli\u003edesalination plants: sea water, permeate, and also brine, etc.\u003c\/li\u003e \u003cli\u003ewater purification\u003c\/li\u003e \u003cli\u003eleakage detection\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eFrom Standard Models to Highly Custom Versions\u003c\/h3\u003e For easy ordering, the standard range of the OPTIFLUX 2000 Series covers all popular sizes, flange materials, and connections (ASME, EN, JIS, AWWA). However, our extensive engineering department can provide solutions for all specifications beyond our standard range. Requests for special sizes, flange connections, pressure ratings, building lengths, and materials will always get a serious review. Whenever possible, we will even engineer an electromagnetic flowmeter that fits your precise requirements. \u003c\/div\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eEasy To Install Electromagnetic Flowmeter\u003c\/h3\u003e Fitting the OPTIFLUX 2000 Series is easy with the flanged design and standard ISO insertion lengths. To further ease the operation, the OPTIFLUX 2000 Series can install without filters and straighteners. Even grounding rings are not necessary with the patented \"Virtual Reference\" option on the IFC 300 signal converter. \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 Rating Options\u003c\/a\u003e\u003c\/h3\u003e Installation in measurement chambers subject to (constant) flooding is possible with the IP68 rating version. The chambers can even be completely surpassed if the IP68 version is combined with our special subsoil coating, thus allowing the OPTIFLUX 2000 to be installed directly in the ground. \u003c\/div\u003e \u003ch3\u003eElectromagnetic Flowmeter for Custody Transfer Processes\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 6\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e In combination with the IFC 300 signal converter, the OPTIFLUX 2000 is suitable for custody transfer applications. It meets the requirements of OIML R49 and can also verify according to Annex MI-001 of the Measuring Instruments Directive (MID) \/ UK Regulation 2016. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364012675,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/OPTIFLUX-2100-krohne-magmeters-magnetic-flow-controller-psc-texas_6d237ab2-7984-4ce8-8b37-df55757d7279.png?v=1763385154"},{"product_id":"inline-flow-meter-master-touch-series-86008700-mp-haz","title":"Inline Flow Meter, Master-Touch Series 8600-8700 MP HAZ","description":"\u003cp\u003eThe 8600-8700 MP Inline Flow Meter Series provides accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\" rel=\"nofollow noopener\" target=\"_blank\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy: ± 1% of reading + 0.5% of full scale + GTC\u003c\/li\u003e\n\u003cli\u003erepeatability: ± 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003esensor response time: 1 second to 63% of final value\u003c\/li\u003e\n\u003cli\u003egas temperature coefficient (GTC): 0.02% full scale\/˚C\u003c\/li\u003e\n\u003cli\u003egas pressure effect: negligible over ± 50% of factory calibration pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaster-Touch Series 8600-8700 MP HAZ, Inline Flow Meter\u003c\/h3\u003e\n\u003cp\u003eMaster-Touch Series products include a rugged, cleanable, \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flow sensor\u003c\/a\u003e. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, as well as stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged in addition to being relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. Then it is controlled by the temperature sensor and bridge circuitry. Furthermore, our bridge maintains the overheat temperature and counterbalances the temperature effects through proprietary temperature compensation techniques.\u003c\/p\u003e\n\u003ch3\u003e8600-8700 Series Inline Flow Meter for Use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazardous Locations\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cp\u003eOur inline flow meter for thermal mass flow measurement includes a flow section that is usually specified to match the userâs flow conduit and is then plumbed directly into the process line. This design also has the sensing elements mounted directly in the flow section for exposure to the process gas. This thermal mass flow inline flow meter is available in sizes from 1\/4\" pipe through 4\" pipe or tube and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as necessary. Pipe sizes more than 4\" typically require insertion style thermal mass flow meters. This integral style inline flow meter has all the electrical components and connections located within one enclosure. Additionally, this enclosure offers \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eratings for hazardous environments\u003c\/a\u003e. The enclosure mounts directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly.\u003c\/p\u003e\n\u003ch3\u003eOperating Principle\u003c\/h3\u003e\n\u003cp\u003eThermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. Furthermore, our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. In addition, our microcontroller operate with smart sensor technology that preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, which causes an increase in the power necessary to maintain a balance between the RTDs. As a result, this increase directly relates to the gas molecular rate of flow. Our sensors also feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes. So, the output signal is a true mass flow rate signal.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Master-Touch Series 8600â8700 MP HAZ\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\"\u003e\u003cimg class=\"alignright wp-image-26148 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp.jpg\" alt=\"Eldridge-Products-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp\" width=\"750\" height=\"513\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eCertifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eCSA\/CUS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIECEx\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eKOSHA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApprovals\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eT2\u003c\/li\u003e\n\u003cli\u003eT3\u003c\/li\u003e\n\u003cli\u003eT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Orientation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMeter Housing\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003edisplay with keypad\u003c\/li\u003e\n\u003cli\u003eno display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003ePipe Information\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 4\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 6\" (custom options available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eModbus RTU\u003c\/a\u003e), Multi-Range + Temp Out, Multi-Range + No Temp, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eBACnet\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eProfibus\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e (when applicable): Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMounting Requirements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMNPT Ends\u003c\/li\u003e\n\u003cli\u003eButt End\u003c\/li\u003e\n\u003cli\u003eFlange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSensor Wetted Materials Options\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eStainless Steel 316L\u003c\/li\u003e\n\u003cli\u003eHastelloy C-276\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364340355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/EPI-Master-Touch-8600-8700-MP-Inline-Flow-Meter-Gas-Thermal-Mass-Flow-Meter-Process-Solutions-Corp_60549b24-6b99-4485-bd1a-d8863121157d.png?v=1763385157"},{"product_id":"eldridge-products-valumass-series-500-val-inline-flow-meter","title":"Eldridge Products, ValuMass Series 500 VAL Inline Flow Meter","description":"ValuMass 500 VAL flow meters provide accurate, consistent, and rapid real-time \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e with a sensor that is both temperature and pressure corrective. Each flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e, is undergoes calibration using standards traceable to the \u003ca href=\"https:\/\/www.nist.gov\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNational Institute of Standards and Technology (NIST)\u003c\/a\u003e. Like the ValuMass Series 540, the ValuMass Series 500 inline \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/thermal-mass-flow-meters\/\"\u003ethermal mass flowmeter\u003c\/a\u003e also uses the proprietary temperature compensation techniques using two RTD (resistance temperature detectors). This design allows the ValuMass Series to deliver accurate measurements day in, day out. If you require reliable mass measurement for an air and gas flow application with an inline installation, the ValuMass Series 500 is an excellent choice that provides great value at a great price. \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-26153 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas.jpg\" alt=\"Eldridge-Products-Inc-EPI-Valu-Mass-In-Line-Thermal-Mass-Flow-Meters-500VAL-PSC-Texas\" width=\"1000\" height=\"681\"\u003e\u003c\/a\u003e \u003ch3\u003eThermal Mass Flow Meters\u003c\/h3\u003e ValuMass 500 Series VAL is a rugged, cleanable, thermal mass flow sensor. These flow meters consist of a sensor assembly that utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors are constructed of reference grade platinum, ceramic, glass, and stainless steel. Two platinum resistance sensors rely upon a ceramic substrate that then receives a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large and rugged as well as relatively insensitive to dirt buildup. During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The second sensor is forced through self-heating to a constant temperature above that of the gas stream. In addition, it is controlled by the temperature sensor and bridge circuitry. Our bridge maintains the overheat temperature and counterbalances the temperature effects through our proprietary temperature compensation techniques. \u003ch3\u003e500 Series Flow Meter from \u003ca href=\"https:\/\/psctexas.com\/brand\/epi\/\"\u003eEldridge Products Inc. (EPI)\u003c\/a\u003e\n\u003c\/h3\u003e Our inline style thermal mass flow meters include a flow section that matches the userâs flow conduit and then usually plumbs directly into the process line. Furthermore, the sensing elements mount directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1\/4\" pipe through 2.5\" pipe. The 3.5\" long flow sections have MNPT ends as standard for easy mounting in the process line (options available for pipe sizes over 2.5\"). Integral style thermal mass flow meters have all the electrical components and connections within one enclosure. This enclosure features a rating for non-hazardous environments. Then the enclosure mounts directly to the inline flow section assembly at the point of measurement. The enclosure includes all the electrical connections as well as the linearizing electronics and the display \/ keypad assembly. \u003ch3\u003eOperation Principle\u003c\/h3\u003e Thermal mass flow meters from Eldridge Products use the principle of convective heat transfer to directly measure mass flow. Our proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller smart sensor technology preferentially heats one RTD. Meanwhile, the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal. \u003ch3 style=\"text-align: left;\"\u003eConfiguration Options Eldridge Products - ValuMass 500 Series VAL\u003c\/h3\u003e \u003ch5\u003eMeter Orientation\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Orientation\u003c\/strong\u003e: Horizontal, Vertical\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: left to right, right to left, top to bottom, bottom to top\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting Preferences\u003c\/strong\u003e: Left Side, Right Side, Above Pipe, Below Pipe\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMeter Housing\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edisplay with keypad\u003c\/li\u003e \u003cli\u003eno display\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003ePipe Information\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Size Range\u003c\/strong\u003e: 1\/4\" to 2.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLength of Flow Section\u003c\/strong\u003e: 3.5\" (custom options available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInner Diameter\u003c\/strong\u003e: 0.364\" (6.35 mm) [based on ANSI standards]\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePipe Standard\u003c\/strong\u003e: ANSI, Schedule 40\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInput Power and Communication Options\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12-18 VDC, 18-24 VDC, VAC 105-120, VAC 210-240\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: Standard (\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus RTU\u003c\/a\u003e), \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Flow Output\u003c\/strong\u003e: Self Powered, Isolated-Loop Powered\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e4-20 mA Temp Output\u003c\/strong\u003e: Standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Flow Output\u003c\/strong\u003e (when applicable): 0-5, 0-10\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVDC Temp Output\u003c\/strong\u003e: 0-5, 0-10\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMounting Requirements\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eMNPT Ends\u003c\/li\u003e \u003cli\u003eButt End\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eSensor Wetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eStainless Steel 316L\u003c\/li\u003e \u003c\/ul\u003e","brand":"Eldridge Products (EPI)","offers":[{"title":"Default Title","offer_id":45878364405891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Eldridge-Products-ValuMass-Inline-Thermal-Mass-Flow-Meter-500-VAL-EPI-Process-Solutions-Corp.png?v=1763385160"},{"product_id":"nivofloat-series-float-level-switch","title":"NIVOFLOAT Series, Float Level Switch","description":"\u003cul\u003e\n\u003cli\u003eoperation without power supply\u003c\/li\u003e\n\u003cli\u003elow cost polypropylene level switch\u003c\/li\u003e\n\u003cli\u003eairtight, dual-walled chamber\u003c\/li\u003e\n\u003cli\u003emercury-free microswitch\u003c\/li\u003e\n\u003cli\u003eadjustable switch differential\u003c\/li\u003e\n\u003cli\u003efor low density liquids\u003c\/li\u003e\n\u003cli\u003e3 year manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNIVOFLOAT NL–100 Float Level Switch\u003c\/h2\u003e\n\u003cp\u003eThe NIVOFLOAT NL–100 type float level switch from NIVELCO feature mercury-free contact and is suitable for level switching of drinking water, raw water, or polluted liquids with low solid content. The double-chambered float and the sealing of the cable outlet provide hermetic sealing and water-proof operation. The NIVOFLOAT NL–100 floats on the level of the measured liquid because its relative density is less than the water. The level switching is done when the contact reaches the ±45˚ switching angle. The switching differential of the level switch is adjustable by the position of the counterweight on the cable. The level switches should be arranged appropriately in case of multi-level switching tasks to avoid undesired tangling of the cables.   \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFeatures of NL-100 Float Level Switch\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edual-chambered float\u003c\/li\u003e\n\u003cli\u003eswitching differential is adjustable by counterweight\u003c\/li\u003e\n\u003cli\u003eup to 66 feet cable length\u003c\/li\u003e\n\u003cli\u003emedium temperature up to 122˚F\u003c\/li\u003e\n\u003cli\u003eprocess pressure maximum 1 bar (14.5 psi)\u003c\/li\u003e\n\u003cli\u003evariants for potable water available\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP68 rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eCommon Uses of NL-100 Float Level Switch\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003epotable water\u003c\/li\u003e\n\u003cli\u003eindustrial and communal sewage\u003c\/li\u003e\n\u003cli\u003etank filling \/ emptying control\u003c\/li\u003e\n\u003cli\u003eoverfill protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNIVOFLOAT NW–100 Tilting Float Level Switch\u003c\/h2\u003e\n\u003cp\u003eThe NIVOFLOAT NW–100 tilting level switch featuring mercury free contact is suitable for level switching of sewage, polluted liquids or drinking water. The double-chambered float and the sealing of the cable outlet provide hermetic sealing and water-proof operation. The float should be immersed to the required level and fixed if needed. At the given level, the float will switch by tilting. The special shape of the float ensures proper tilting without using a counterweight.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFeatures of NW-100 Tilting Float Switch\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003especial float shape\u003c\/li\u003e\n\u003cli\u003edual-chambered float\u003c\/li\u003e\n\u003cli\u003eup to 66 feet cable length\u003c\/li\u003e\n\u003cli\u003emedium temperature up to 122˚F\u003c\/li\u003e\n\u003cli\u003eprocess pressure maximum 2 bar (30 psi)\u003c\/li\u003e\n\u003cli\u003evariants for potable water available\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP68 rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch4\u003eCommon Uses of NW-100 Tilting Float Level Switch\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eindustrial and communal sewage\u003c\/li\u003e\n\u003cli\u003esuitable for drinking water\u003c\/li\u003e\n\u003cli\u003etank filling, emptying control\u003c\/li\u003e\n\u003cli\u003eoverfill protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNIVOFLOAT Series Specifications\u003c\/h2\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e32-122˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003emaximum 14.5 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eSwitch rating: 250 VAC, 10(3)A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eIngress Protection\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eCommon Uses of NIVOFLOAT Float Level Switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003elevel switch from potable water to sewage\u003c\/li\u003e\n\u003cli\u003esuitable also for tanks and basins\u003c\/li\u003e\n\u003cli\u003efail-safe indication and pump control\u003c\/li\u003e\n\u003cli\u003ewater and wastewater industry\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878364602499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Nivelco_NIVOFLOAT-tilting-float-level-switch-water-tank-measurement-sewage-wastewater_607a5520-66af-48c5-84f2-a5f778b6695e.png?v=1763385168"},{"product_id":"integral-orifice-dp-flow-meter-run-assembly","title":"Integral Orifice DP Flow Meter Run Assembly","description":"The integral orifice meter run assembly is a \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/differential-pressure\/\"\u003edifferential pressure flow meter\u003c\/a\u003e for the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal water and wastewater industry\u003c\/a\u003e. They're specifically designed for smaller line sizes where the surface roughness, weld seams, and other geometrical imperfections have a relatively big influence on the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e uncertainty. This DP flow meter, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, features a minimum length of upstream and downstream pipe. Thus, it reduces additional uncertainties of the installation to a minimum. This DP flow meter is suitable for process and allocation measurement of gases and liquids such as viscous fluids, fluids with suspended solids, or fluids with gas entrainment. We offer the complete orifice assembly with orifice meter run, DP transmitter, valves, accessories, engineering, and documentation. This DP flow meter comes pressure tested and ready for commissioning. The meter run is available in various designs and is compliant with the requirements of the \u003ca href=\"https:\/\/www.iso.org\/standard\/79179.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eISO 5167\u003c\/a\u003e, such as pressure tap orientation and dimensions. It is fully machined and straightened to meet the highest dimensional expectations. If necessary, we can provide an additional calibration in line with the final operating conditions. We also supply special constructions such as redundant taps, integrated flow conditioner, certain paint specifications, or advanced NDTs from one source and in accordance with relevant standards (ISO 5167, etc.). \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-7060-dp-transmitter\/\"\u003e\u003cimg class=\"alignright wp-image-25936 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-optibar-dp-7060-differential-pressure-dp-flow-measurement-meter-process-solutions-corp.png\" alt=\"KROHNE-optibar-dp-7060-differential-pressure-dp-flow-measurement-meter-process-solutions-corp\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e \u003ch3\u003eOPTIBAR DP Flow Meter\u003c\/h3\u003e The sophisticated \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-7060-dp-transmitter\/\"\u003eOPTIBAR DP 7060\u003c\/a\u003e and the compact \u003ca href=\"https:\/\/psctexas.com\/product\/optibar-dp-3050-dp-pressure-transmitter\/\"\u003eOPTIBAR DP 3050\u003c\/a\u003e DP transmitters are the perfect companion for this DP flow meter solution. They are 3D linearized and ensure advanced performance even at high static pressures. Furthermore, the OPTIBAR DP series has outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations. \u003ch3\u003eFeatures of the Integral Orifice DP Flow Meter Run Assembly\u003c\/h3\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003estandardized calibrated orifice assembly for high accuracy requirements\u003c\/li\u003e \u003cli\u003edesign according to ISO 5167 as well as ISO TR 15377 from DN15 to DN100 (0.5 to 4\"), other sizes and designs on request\u003c\/li\u003e \u003cli\u003eelimination of additional uncertainties due to installation effects\u003c\/li\u003e \u003cli\u003elow TCO (Total Cost of Ownership) due to reduced engineering, commissioning, and installation costs\u003c\/li\u003e \u003cli\u003ereduced need for recalibration in the field through advanced 3-D linearized OPTIBAR DP transmitters\u003c\/li\u003e \u003cli\u003ecomplete DP flow meter solution with orifice meter run, manifold, DP transmitter, sizing, and documentation from a single source\u003c\/li\u003e \u003cli\u003eredundancy available (1oo2, 2oo3)\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART 7\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION fieldbus\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\u003c\/a\u003e communication options\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eSIL 2\/3 certified versions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eEx ia, Ex d approvals\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of Differential Pressure Flow Meters\u003c\/h3\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eDP flow measurement in applications with small pipe diameters\u003c\/li\u003e \u003cli\u003eprocess measurement\u003c\/li\u003e \u003cli\u003eallocation measurement\u003c\/li\u003e \u003cli\u003ecustody transfer (CT) as well as fiscal measurement\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364831875,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optibar-7060-dp-flow-meter-Integral-orifice-meter-run-assembly-process-solutions-corp.png?v=1763385176"},{"product_id":"optiflux-2050-for-water-flow-measurement","title":"OPTIFLUX 2050 for Water Flow Measurement","description":"The OPTIFLUX 2050 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flowmeter (magmeter)\u003c\/a\u003e for basic and advanced water \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow measurement\u003c\/a\u003e in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003ewastewater and municipal water applications\u003c\/a\u003e. It is suitable for all cost-effective measurements where extremely high accuracy, extensive diagnostics, or a wide range of communication options are not a priority. This magmeter has a wide diameter range: DN25 to DN1200 (1 to 48\"). In addition, this magmeter for water flow measurement offers all available approvals for drinking water. The extra isolation of its electronics as well as its special housing makes the OPTIFLUX 2050, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, particularly suitable for use in areas with extreme humidity. \u003cimg class=\"alignright wp-image-25908 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas.jpg\" alt=\"KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Flow-Measurement-Wastewater-Treatment-Process-Solutions-Texas\" width=\"627\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003eflange: DN25 to DN1200 (1 to 48\"), maximum PN40 \/ ASME Cl 300\u003c\/li\u003e \u003cli\u003e4-20 mA, pulse, frequency, status, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003erugged liners suitable for any water and wastewater application\u003c\/li\u003e \u003cli\u003eproven and unsurpassed lifetime, huge installation base\u003c\/li\u003e \u003cli\u003edrinking water approvals such as KTW, KIWA, DVGW, ACS, NSF, WRAS\u003c\/li\u003e \u003cli\u003emeets potable water standards such as ACS, DVGW, NSF, TZW, WRAS, etc.\u003c\/li\u003e \u003cli\u003ecompliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, as well as EN 14154)\u003c\/li\u003e \u003cli\u003eeasy installation and commissioning as well as maintenance-free\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 2050 also features a full bore design with wear resistant liner materials. Installation in measurement chambers subject to (constant) flooding is possible with the \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 \/ NEMA 6P rating\u003c\/a\u003e version. This magmeter for water flow measurement comes with current output (including HART) and active pulse\/frequency output in addition to Modbus. Furthermore, operators can carry out a full on-site verification of the OPTIFLUX 2050 without process interruption using the OPTICHECK service tool. \u003ch3\u003eFeatures of the OPTIFLUX 2050 Magmeter for Water Flow Measurement*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP68 rating\u003c\/a\u003e electronics for use in areas with extreme humidity and chances of flooding\u003c\/li\u003e \u003cli\u003estandard wet calibration\u003c\/li\u003e \u003cli\u003ePP or hard rubber liner: excellent chemical resistance\u003c\/li\u003e \u003cli\u003esignal converter with display or as blind version\u003c\/li\u003e \u003cli\u003etamper proof, fully welded construction, also available in customer specific constructions\u003c\/li\u003e \u003cli\u003efull bore design: no moving parts, no wear, no pressure loss\u003c\/li\u003e \u003cli\u003estandard in house wet calibration of flow sensors up to diameter DN3000\u003c\/li\u003e \u003cli\u003eon-site verification of flowmeter with OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses for the OPTIFLUX 2050 for Water Flow Measurement\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eall simple municipal water as well as wastewater applications\u003c\/li\u003e \u003cli\u003eabstraction and irrigation\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation and treatment systems\u003c\/li\u003e \u003cli\u003ewater purification and desalination\u003c\/li\u003e \u003cli\u003erevenue metering or billing leakage detection\u003c\/li\u003e \u003cli\u003eirrigation as well as cooling water\u003c\/li\u003e \u003cli\u003esewage and sludge\u003c\/li\u003e \u003cli\u003esea water\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364864643,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-OPTIFLUX-2050-Magmeter-for-Municipal-Water-Wastewater-Flow-Measurement-Process-Solutions-Corp.png?v=1763385178"},{"product_id":"optiflux-1300-magnetic-flow-meter","title":"OPTIFLUX 1300 Magnetic Flow Meter","description":"The OPTIFLUX 1300 is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF), or magmeter\u003c\/a\u003e, with a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact\u003c\/a\u003e, lightweight wafer-style design. This magnetic flow meter is an economical solution for applications with conductive liquids (â¥ 5 Î¼S\/cm) in addition to higher solid content (up to 70%). In comparison with the OPTIFLUX 1100, the OPTIFLUX 1300, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, offers better accuracy. Furthermore, this \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow meter\u003c\/a\u003e meets the demands of many applications in the \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal and wastewater industry\u003c\/a\u003e. This magnetic flow meter is also a preference in dosing systems, compact skids, chemical handling systems, or pump and firefighting systems. \u003cimg class=\"alignright wp-image-25895 size-full\" style=\"width: 300px;\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/07\/KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas.jpg\" alt=\"KROHNE-optiflux-1300-magnetic-flow-meter-waste-water-treatment-flow-sensor-psc-texas\" width=\"406\" height=\"750\"\u003e \u003cul\u003e \u003cli\u003e3 x 4-20 mA, \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hart\/\"\u003eHART\u003c\/a\u003e, \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/foundation-fieldbus\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFOUNDATION Fieldbus\u003c\/a\u003e, \u003ca href=\"https:\/\/www.profibus.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eProfibus-PA\/DP, PROFINET\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003elightweight as well as compact for easy handling and space saving installation\u003c\/li\u003e \u003cli\u003eaffordable price\u003c\/li\u003e \u003cli\u003eexcellent chemical resistance\u003c\/li\u003e \u003cli\u003eno pressure loss\u003c\/li\u003e \u003cli\u003einsensitive to vibrations\u003c\/li\u003e \u003c\/ul\u003e The OPTIFLUX 1300 features a reinforced PFA liner as well as \u003ca href=\"https:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy\u003c\/a\u003e electrodes that guarantee excellent chemical resistance and a large temperature range up to 248ËF (120ËC). This EMF has no internal moving parts, does not require maintenance, and is also insensitive to vibrations. It comes with various digital communication options and approvals for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e. Furthermore, operators can use the OPTICHECK service tool for full on-site verification of this flow meter without process interruption. \u003ch3\u003eFeatures of the OPTIFLUX 1300 Magnetic Flow Meter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ebi-directional flow measurement over a wide dynamic range (turndown ratio: 1000:1)\u003c\/li\u003e \u003cli\u003elightweight and compact wafer-style (\"sandwich\") design for space saving installation\u003c\/li\u003e \u003cli\u003estandard measurement accuracy: Â±0.3% or Â±1 mm\/s of measured value (MV)\u003c\/li\u003e \u003cli\u003eextensive sensor and process diagnostics (including \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNE 107\u003c\/a\u003e)\u003c\/li\u003e \u003cli\u003ereinforced PFA liner: smooth surface, excellent chemical resistance\u003c\/li\u003e \u003cli\u003epipe cross-section without restrictions for slurries with non abrasive solid particles\u003c\/li\u003e \u003cli\u003eno internal moving parts or maintenance requirements\u003c\/li\u003e \u003cli\u003eon-site verification of this magnetic flow meter via OPTICHECK service tool\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Uses of a Magnetic Flow Meter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003egeneral use in \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/\"\u003emunicipal as well as wastewater applications\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003emore demanding water applications such as potable water, raw water, wastewater, salt water, heated and cooled water\u003c\/li\u003e \u003cli\u003efiscal metering (custody transfer)\u003c\/li\u003e \u003cli\u003emonitoring of distribution networks\u003c\/li\u003e \u003cli\u003ewater circulation in addition to treatment systems\u003c\/li\u003e \u003cli\u003edosing systems, filtration systems, and also pump control\u003c\/li\u003e \u003cli\u003ewater flow monitoring\u003c\/li\u003e \u003cli\u003eheat transfer and cooling systems\u003c\/li\u003e \u003cli\u003eviscous flows such as mud, slurry, sludge, etc.\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"Default Title","offer_id":45878364897411,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/KROHNE-optiflux-1300-magnetic-flow-meter-municipal-water-wastewater-flow-measurement-process-solutions-corp.png?v=1763385180"},{"product_id":"nivoswitch-level-switch-for-liquids-vibrating-fork","title":"NIVOSWITCH Level Switch for Liquids, Vibrating Fork","description":"\u003cp style=\"margin-top: 30px;\"\u003eThe NIVOSWITCH is a vibrating fork level switch. It's ideal for use in shale oil and gas fields. There are currently hundreds of NIVOSWITCH, from NIVELCO, in use in the United States in field production tanks, condensate tanks, separators, and more. This level switch can install vertically or horizontally and can perform as either a high-level switch or a low-level switch. \u003ca title=\"API Association\" href=\"https:\/\/www.api.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003eAPI\u003c\/a\u003e recommended practice states that unmanned facilities should be instrumented with both a continuous level transmitter, as well as a high level shut off switch to prevent overfill.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eno moving parts\u003c\/li\u003e\n\u003cli\u003eself-cleaning in most mediums\u003c\/li\u003e\n\u003cli\u003estainless steel and plastic-coated probes\u003c\/li\u003e\n\u003cli\u003epipe extension up to 10 feet\u003c\/li\u003e\n\u003cli\u003evarious output configurations\u003c\/li\u003e\n\u003cli\u003ehigh or low fail-safe mode\u003c\/li\u003e\n\u003cli\u003eplastic, aluminum, or stainless steel housing\u003c\/li\u003e\n\u003cli\u003eexplosion-proof variants available\u003c\/li\u003e\n\u003cli\u003efor corrosive, thick, turbulent, and flowing liquids\u003c\/li\u003e\n\u003cli\u003emedium pressure: up to 580 psig\u003c\/li\u003e\n\u003cli\u003e3 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e20-255 V AC, 20-60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e−40 to 158˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e−40 to 266˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003emaximum 580 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1 or 2 relays (SPDT), 2-wire AC \/ DC, transistor (PNP, NPN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1\", 1½\", 2\" or flanges or hygienic fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca rel=\"noopener\" title=\"IP Rating For Industrial Instrumentation\" href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eIP67, IP68, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e\n\u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eATEX, IEC Ex, DNV (Marine), UKCA Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch2\u003eNIVOSWITCH Vibrating Fork Level Switch for Shale Oil and Gas Fields\u003c\/h2\u003e\n\u003cp\u003eNIVELCO NIVOSWITCH R−400\/500 vibrating fork level switches with a parallel vibrating fork are suitable for detecting the level of liquids. Mounting on pipes and tanks, it can control filling and emptying and can also generate fail-safe alarms providing overfill or dry-run protection. The operating principle is based on that the electronic circuit excites a vibration in the fork probe. When the medium reaches and covers the fork, its vibration changes. The fork will start vibrating freely again as the medium sets it free. Its electronics sense the change of vibration and give an output signal after a selected delay. The plastic-coated version is ideal for use in aggressive media, and the high polish version is ideal for use in abrasive media.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 30px;\"\u003ePNP\/NPN transistor output versions can connect directly to a PLC or relay unit. Certain types of NIVOSWITCH vibrating forks are able to solve switching tasks of high-current loads with the help of UNICONT PKK switching amplifiers. Additionally, a hazardous area rating NIVELCO UNICONT PKK–312–8 Ex is an intrinsic safety switching unit for Ex-rating vibrating forks.\u003c\/p\u003e\n\u003ccenter\u003e\u003cbr\u003e\u003c\/center\u003e\n\u003ch2\u003eHazardous Area Rating Level Switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"ATEX Certification Standards\" href=\"https:\/\/www.ul.com\/services\/atex-certification-european-union\" rel=\"nofollow noopener\" target=\"_blank\"\u003eATEX\u003c\/a\u003e: Ex ia G, Ex d G\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"IECEx Certification Standards\" href=\"https:\/\/www.iecex.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e: Ex (Ex d G)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"UKCA Certification Standards\" href=\"https:\/\/www.gov.uk\/guidance\/ukca-marking-conformity-assessment-and-documentation\" rel=\"nofollow noopener\" target=\"_blank\"\u003eUKCA\u003c\/a\u003e: Ex (Ex ia G)\u003c\/li\u003e\n\u003cli\u003eDNV: only for RF–400 compact types for liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Uses of Level Switches\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003echemical industry\u003c\/li\u003e\n\u003cli\u003efood and beverage\u003c\/li\u003e\n\u003cli\u003epower plants\u003c\/li\u003e\n\u003cli\u003eoil industry\u003c\/li\u003e\n\u003cli\u003ewater industry\u003c\/li\u003e\n\u003cli\u003emost liquids with minimum 0.7 kg\/dm\u003csup\u003e3\u003c\/sup\u003e density (specific gravity) and maximum 10\u003csup\u003e4\u003c\/sup\u003e mm\u003csup\u003e2\u003c\/sup\u003e\/s (0.1 ft\u003csup\u003e2\u003c\/sup\u003e\/s) viscosity\u003c\/li\u003e\n\u003cli\u003efor liquids \/ free-flowing, powdered solids, and granules\u003c\/li\u003e\n\u003cli\u003efor normal or hazardous, aggressive (acids, solvents) liquids or high viscosity liquids\u003c\/li\u003e\n\u003cli\u003ecovers a large variety of level detection applications such as high\/low fail-safe limit switch or dry run protection, pump controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878364995715,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOSWITCH-liquids-RFM-401nivo-switch-vibrating-fork-level-switch-houston.png?v=1763385184"},{"product_id":"flowlogic-flow-control-system-readout","title":"FlowLogic, Flow Control System \u0026 Readout","description":"Take full command of your flow process with the FlowLogic Flow Control System (PSC6194). This intuitive, high-visibility interface empowers operators, engineers, as well as OEMs alike. Designed for seamless integration with a wide range of mass flow meters and controllers (especially from our partners like \u003ca href=\"https:\/\/psctexas.com\/bronkhorst-flow\/\"\u003eBronkhorst\u003c\/a\u003e), the FlowLogic brings all your critical setpoints, measured values, trends, totals, and more into one 4.3\" full-color touchscreen. Whether using the FlowLogic as a plug-and-play controller and readout on the lab bench or if it's fully integrated into a complete dosing package, this gas and\/or liquid flow meter controller unit delivers the best insight, control, and logging capabilities to improve the success of your application. Whether youâre managing gas flows in a chemical pilot plant, dosing liquids in a food \u0026amp; beverage process or controlling ultra-low flows for research, the FlowLogic puts powerful logic and control in your hands. It supports up to two mass flow controllers and two flow meters. Furthermore, it tracks totalized volumes and offers analog 4-20 mA \/ 0-10V IO or Modbus digital communication for modern automation infrastructure and a wide compatibility across common flow instrumentation. \u003ch3\u003eFlowLogic Flow Control Systems and Readout\u003c\/h3\u003e But itâs not just about specs â itâs about workflow efficiency. FlowLogicâs pre-programmed logic delivers setpoint control, range indication, trending and totalizing out of the box, thus drastically reducing setup time and operator training. For OEMs it becomes a turnkey read-out and control module that shortens your time-to-market; in addition, for process engineers, it becomes a trusted instrument in your control panel. Upgrade your process today and achieve tighter control, richer data visibility, as well as faster commissioning â all backed by Process Solutions Corp.âs expertise in flow instrumentation. The FlowLogic is the smart choice to make your flow processes smoother, safer, and also more scalable. \u003cul\u003e \u003cli\u003e4.3\" Color Touchscreen PLC\u003c\/li\u003e \u003cli\u003ePowers up to \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003e2 flow controllers and 2 flow meters\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eAnalog and Modbus Interface\u003c\/li\u003e \u003cli\u003eData logging capabilities\u003c\/li\u003e \u003cli\u003eUser-friendly touchscreen interface\u003c\/li\u003e \u003cli\u003eIndication and Operation of: \u003cul\u003e \u003cli\u003eMeasured Value\u003c\/li\u003e \u003cli\u003eSetpoint\u003c\/li\u003e \u003cli\u003eInstrument Range\u003c\/li\u003e \u003cli\u003eTrending Values Totalizer (limit, value, totalizer mode, new setpoint)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePreprogrammed Flow Control System for Liquid or Gas Flow Control\u003c\/h3\u003e \u003ch4\u003e\u003cimg class=\"wp-image-29190 size-full alignright\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2019\/05\/IMG_2144.png\" alt=\"PSC-6194-MFC-Automation-Flow-Controller-HMI-for-Flow-Control\" width=\"750\" height=\"373\"\u003e\u003c\/h4\u003e The FlowLogic is an all-in-one flow controller and readout unit that comes preprogrammed with standard flow control functions for a user friendly interface. The touchscreen HMI offers intuitive control and is also capable of data logging and other useful functions for batching or continuous production processes. Although standard packages are available, our engineers can work closely with your team to develop a unique flow controller that seamlessly integrates with your process. Whether your application involves gas flow or liquid flow such as liquid dosing applications, FlowLogic offers easy but powerful control. \u003ch3\u003eFlowLogic Flow Controller for MFCs and Readout System\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eCompatibility (alphabetical): Alicat Scientific, \u003ca href=\"https:\/\/psctexas.com\/bronkhorst-flow\/\"\u003eBronkhorst Low Flow\u003c\/a\u003e, Brooks Instrument, Dwyer \/ Omega, Florite Mass Flow Control, Fluid Components International (FCI), HORIBA Ltd., Kobold Instruments, MKS Instruments, Sage Metering, Sensirion AG, Sierra Instruments, Teledyne Hastings, as well as more!\u003c\/li\u003e \u003cli\u003eController dimensions: 7.75 W x 7 H x 4.25 D\u003c\/li\u003e \u003cli\u003eAnalog input\/output: 4-20mA, 0-10Vdc\u003c\/li\u003e \u003cli\u003eRemovable memory: microSD\u003c\/li\u003e \u003cli\u003ePower required: 24Vdc\u003c\/li\u003e \u003cli\u003eEthernet LAN port\u003c\/li\u003e \u003cli\u003eFieldbus: Analog (Sub-D 9 pin) \u003ca href=\"http:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus\u003c\/a\u003e (RJ45)\u003c\/li\u003e \u003cli\u003eRatings: General purpose\u003c\/li\u003e \u003cli\u003eDisplay technology: 4.3\" TFT resistive color, 3.53 H x 4.69 W (inches)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878365061251,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PSC6194-flow-controller.jpg?v=1763385186"},{"product_id":"cs11-compact-media-isolated-pressure-sensor","title":"CS11 Compact Media Isolated Pressure Sensor","description":"The CS11 Compact Media Isolated Pressure Sensor features a silicone sensing element with isolation via a fluid filled cavity. Configurations for this \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure sensor\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, are available with a millivolt output signal and \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316L SS wetted material\u003c\/a\u003e for compatibility in a variety of medias. With available pressure ranges from 0-2 up to 2,000 PSI, and a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact design\u003c\/a\u003e, the CS11 is an economical choice in applications with minimal installation space. \u003cul\u003e \u003cli\u003esmall profile with excellent performance\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.25% BFSL accuracy\u003c\/li\u003e \u003cli\u003epressures from 0-2 to 2,000 PSI\u003c\/li\u003e \u003cli\u003ecompact design\u003c\/li\u003e \u003cli\u003eflush diaphragm available\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS11 Compact Media Isolated Pressure Sensor\u003c\/h3\u003e The CS11 Compact Media Isolated Pressure Sensor is an ideal pressure transducer for applications requiring a small profile with reliable, repeatable performance. Threadless configurations with an O-ring seal are available for easy installation into pressure manifolds. Need a threaded connection? No problem! The CS11 can configure with a threaded process connection such as 1\/4\" or 1\/8\" Male NPT. The CS11 not only offers a small profile, but it also offers high performance. Pressure transfers from the 316L SS diaphragm to the sensing element via a fluid filled cavity. This fluid filled design results in a highly stable and fast response pressure measurement over a wide operating temperature range. With its configurable design, this pressure transducer allows broad customization possibilities. Donât see the configuration you need? Contact us today and let us know your requirements! \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Millivolt)\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.5% BFSL \u003csmall\u003e(2 PSI)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X minimum\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5X or 4,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 248ËF\u003c\/li\u003e \u003cli\u003e-40 to 120ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 158ËF\u003c\/li\u003e \u003cli\u003e0 to 70ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1.5% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1.5% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eNo\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 mV\/V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 VDC typical\u003c\/li\u003e \u003cli\u003e10 VDC typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 5 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eInput Impedance\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5000 Ohms, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Impedance\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5000 Ohms, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±2%\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±2%\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"4\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/CS11-Compact-Media-Isolated-Pressure-Sensor-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23757 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/CS11-Compact-Media-Isolated-Pressure-Sensor-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\" alt=\"CS11-Compact-Media-Isolated-Pressure-Sensor-Core-Sensors-Process-Solutions-Texas-Configurations\" width=\"1000\" height=\"393\"\u003e\u003c\/a\u003e \u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nist.gov\/standardsgov\/compliance-faqs-rohs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eRoHS compliant\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of the CS11 Compact Pressure Sensor\u003c\/h3\u003e \u003cul\u003e \u003cli\u003epressure control panels\u003c\/li\u003e \u003cli\u003elow pressure monitoring\u003c\/li\u003e \u003cli\u003egeneral industrial equipment\u003c\/li\u003e \u003cli\u003epressure measurement in confined spaces\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372008067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS11-Compact-Media-Isolated-Pressure-Sensor-Core-Sensors-Process-Solutions-Corp.png?v=1763385479"},{"product_id":"cs14-wetwet-differential-pressure-transducer-1-300-psi","title":"CS14 Wet\/Wet Differential Pressure Transducer, 1-300 PSI","description":"The CS14 Wet\/Wet Differential Pressure Transducer is ideal for various applications including filtration and tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel monitoring\u003c\/a\u003e. A \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316L SS\u003c\/a\u003e oil filled sensor element provides excellent stability over a wide operating temperature range. In addition, the CS14, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers corrosion resistance against various liquids and gases. ItsÂ \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\/\"\u003ecompact design\u003c\/a\u003e makes the CS14 a perfect solution for \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/differential-pressure-transducers\"\u003edifferential measurement\u003c\/a\u003e applications in confined spaces. Configurable options include differential pressure ranges up to 300 PSI and various voltage or 4-20 mA loop power output signals. Furthermore, it's available in both male and female 1\/4\" NPT process connections. \u003cul\u003e \u003cli\u003edifferential pressures from 1 to 300 PSI\u003c\/li\u003e \u003cli\u003eline pressures up to 500 PSI\u003c\/li\u003e \u003cli\u003e316L SS diaphragm \/ oil filled sensor element\u003c\/li\u003e \u003cli\u003ewide operating temperature range\u003c\/li\u003e \u003cli\u003ebi-directional pressure ranges available\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eVersatileÂ Wet\/Wet Differential Pressure Transducer,Â Up to 300 PSID\u003c\/h3\u003e The CS14 Wet\/Wet Differential Pressure Transducer is the ideal solution for differential pressure measurement in industrial applications. For example, it's a great fit for filter condition monitoring, sealed tank level measurement, and \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow measurement\u003c\/a\u003e across an orifice. This \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure sensor\u003c\/a\u003e features a fully welded design without any internal O-rings or seals. Due to its design, the CS14 allows for wet\/wet, wet\/dry, or dry\/dry applications. Differential pressures are available as low as 1 PSID all the way up to 300 PSID. In addition, it supports both uni-directional and bi-directional sensing, which makes the CS14 an excellent solution for a wide variety of applications. \u003ch3\u003eSpecifications for the CS14 Wet\/Wet Differential Pressure Sensor\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Current)\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Voltage)\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eElectrical (Ratiometric)\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â± 0.5% BFSL \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â± 0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Line Pressure\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e500 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMax Differential Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e300 PSI\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X or 500 PSI, \u003csmall\u003ewhichever is less, configured differential pressure\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3X configured differential pressure\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 221ËF\u003c\/li\u003e \u003cli\u003e-40 to 105ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 131ËF\u003c\/li\u003e \u003cli\u003e0 to 55ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â±2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003cli\u003eâ¤ Â± 2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP Rating\u003csup\u003e4\u003c\/sup\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP65 minimum\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 5000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e1-5V 0-5V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-4.5V ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5VDC +\/- 0.5V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"6\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eMax line pressure is the highest common mode pressure that can be applied to the sensor without damage. \u003csup\u003e3\u003c\/sup\u003eOverpressure and burst pressure are the maximum differential pressure that can be applied to the high or low side before damage to the sensor will occur. \u003csup\u003e4\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact factory for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eConfiguration Guide\u003c\/h3\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/cs14-wet-wet-differential-pressure-transmitter-core-sensors-process-solutions-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23680 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/06\/cs14-wet-wet-differential-pressure-transmitter-core-sensors-process-solutions-texas.jpg\" alt=\"cs14-wet\/wet-differential-pressure-transmitter-core-sensors-process-solutions-texas\" width=\"1000\" height=\"315\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eApprovals\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking#\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ul.com\/services\/restriction-hazardous-substances-directive-rohs-compliance-services\" target=\"_blank\" rel=\"nofollow noopener\"\u003eRoHS Compliant\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003efiltration\u003c\/li\u003e \u003cli\u003etank level monitoring\u003c\/li\u003e \u003cli\u003ecryogenic bulk tank level measurement\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372139139,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs14-wet-wet-differential-pressure-sensor-core-sensors-psc-texas.png?v=1763385483"},{"product_id":"cs51-non-incendive-low-pressure-transducer-1-49-psi","title":"CS51 Non-Incendive Low Pressure Transducer, 1-49 PSI","description":"The CS51 Non-Incendive Low Pressure Transducer is a high strength sensor for low pressure measurements in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass 1, Division 2 hazardous locations\u003c\/a\u003e. The CS51 features an all welded \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction that offers a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS51, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, a versatile \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/hazloc-pressure-transducers\"\u003ehazardous location pressure transducer\u003c\/a\u003e that's capable of operating in some of the harshest conditions. The CS51 is an excellent solution for applications such as \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e, external fuel tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e, and process control instrumentation. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003eno conduit installation necessary\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/li\u003e \u003cli\u003epressures from 1 to 49 PSI\u003c\/li\u003e \u003cli\u003esee \u003ca href=\"https:\/\/psctexas.com\/product\/cs50-non-incendive-pressure-transducer\/\"\u003emodel CS50\u003c\/a\u003e for pressures 50 PSI and above\u003c\/li\u003e \u003cli\u003emedia isolated\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS51 Non-Incendive Low Pressure Transducer\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS51 Non-Incendive Low Pressure Transducer offers an integral Turck Minifast electrical connection. When combined with a CSA Division 2 approved \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck cordset\u003c\/a\u003e and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. You can \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003elearn more about the Turck Minifast electrical connection here: http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e *We recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23745 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration.jpg\" alt=\"CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configuration\" width=\"1000\" height=\"359\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eApprovals and Certifications for this Non-Incendive Low Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of the CS51\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003evapor recovery\u003c\/li\u003e \u003cli\u003eprocess controls\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372270211,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS51-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385487"},{"product_id":"cs54-non-incendive-differential-pressure-transducer-1-50-psi","title":"CS54 Non-Incendive Differential Pressure Transducer, 1-50 PSI","description":"The CS54 Non-Incendive Differential Pressure Transducer is a high strength sensor for differential pressure measurements of liquids and gases in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 2 hazardous locations\u003c\/a\u003e. A \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316L SS oil filled sensor\u003c\/a\u003e element provides excellent stability over a wide operating temperature range. In addition, this \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure transducer\u003c\/a\u003e, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers corrosion resistance against various liquids and gases. Differential pressure ranges up to 50 PSI are available with 1\/4\" MNPT or FNPT process connections. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/hazloc-pressure-transducers\"\u003ehazardous area pressure sensors\u003c\/a\u003e in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003eno conduit installation necessary\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/li\u003e \u003cli\u003edifferential pressures from 1 to 50 PSI\u003c\/li\u003e \u003cli\u003eline pressures up to 500 PSI\u003c\/li\u003e \u003cli\u003ebi-directional pressure ranges available\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS54 Non-Incendive Differential Pressure Sensor\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS54 Non-Incendive Differential Pressure Transducer offers an integral Turck Minifast electrical connection. When combined with a CSA Division 2 approved \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck\u003c\/a\u003e cordset and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. You can \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003elearn more about the Turck Minifast electrical connection here: psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e \u003cb\u003e*\u003c\/b\u003eWe recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eModel Configuration Guide\u003c\/h3\u003e Not all configurations are available. Our sales team can recommend the closest available configuration based on your requirements.Â Contact us for configurations not shown. \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23737 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations.jpg\" alt=\"CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas-Configurations\" width=\"1000\" height=\"319\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping) approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCommon Uses of the CS54 Non-Incendive Differential Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003efiltration\u003c\/li\u003e \u003cli\u003ecryogenic bulk tank \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel measurement\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ecompression systems\u003c\/li\u003e \u003cli\u003etest stands\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878372335747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CS54-Non-Incendive-Differential-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp.png?v=1763385489"},{"product_id":"cs10-industrial-pressure-transducer-vacuum-45000-psi","title":"CS10 Industrial Pressure Transducer, Vacuum - 45,000 PSI","description":"\u003cp\u003eThe CS10 Industrial Pressure Transducer is ideal for demanding industrial applications. The CS10, from Core Sensors, uses \u003ca href=\"https:\/\/psctexas.com\/mems-tech\/\" target=\"_blank\" title=\"MEMS Sensor Technology\" rel=\"noopener\"\u003eMEMS silicon strain gages\u003c\/a\u003e on a stainless steel or nickel alloy sensing element. It offers analog voltage or 4-20 mA loop power output signals. Various process connections are available in 17-4PH or 316L stainless steel or in nickel alloy including Hastelloy C276 and Inconel 718. The choice of connection, or wetted materials, can allow the CS10 to be suitable for use in a wide variety applications, such as use with corrosive liquids or gases. Electrical connections include cable or various integral connectors. Semi-custom and fully custom designs are available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epressures from vacuum to 45,000 PSI\u003c\/li\u003e\n\u003cli\u003ehighly configurable design\u003c\/li\u003e\n\u003cli\u003eoptional integral snubber\u003c\/li\u003e\n\u003cli\u003ereverse polarity and EMI protection\u003c\/li\u003e\n\u003cli\u003eoxygen cleaning available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCS10 Industrial Pressure Transducer\u003c\/h2\u003e\n\u003cp\u003eThe CS10 Industrial Pressure Transducer is the ideal solution for demanding industrial applications where ruggedness and reliability are top priority. Users can choose from various threaded connection sizes, pressure ranges, various electrical connections including integral cable or connectors, wetted materials options, and various output signals. Pressure options range from vacuum to 45,000 PSI. This level of customization the CS10 to solve just about any measurement challenge.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100.087%; height: 692.102px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: center; width: 36.1636%; height: 19.5938px;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 30.0232%; height: 19.5938px;\"\u003eThermal\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 29.9137%; height: 19.5938px;\"\u003eEnvironmental\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 591.469px;\"\u003e\n\u003ctd valign=\"top\" style=\"width: 36.1636%; height: 591.469px;\"\u003e\n\u003cp style=\"text-align: left;\"\u003eAccuracy @ 77˚F (25˚C)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% BFSL\u003c\/li\u003e\n\u003cli\u003e≤ ±0.5% BFSL \u003csmall\u003e(\u0026lt; 2 PSI \u0026amp; \u0026gt; 10,000 PSI)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003cli\u003e≤ ±1% BFSL \u003csmall\u003e(millivolt output signal)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.25% of FS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e100 million\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2X minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5X or 60,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"width: 30.0232%; height: 591.469px;\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 185˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 85˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 248˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 120˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e32 to 131˚F\u003c\/li\u003e\n\u003cli\u003e0 to 55˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e-40 to 257˚F\u003c\/li\u003e\n\u003cli\u003e-40 to 125˚C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003cli\u003e≤ ±2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±1% of FS\u003c\/li\u003e\n\u003cli\u003e≤ ±2% of FS \u003csmall\u003e(2 PSI \u0026amp; below)\u003c\/small\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"width: 29.9137%; height: 591.469px;\"\u003e\n\u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eYes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP Rating\u003c\/a\u003e\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" title=\"International Electrotechnical Commission\"\u003eIP65 minimum\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 81.0391px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 96.1005%; height: 81.0391px;\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis, and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eElectrical Specifications for the CS10 Industrial Pressure Transducer\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eLow Power\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eMillivolt\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e20 mA, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~250 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e1-5 V\u003c\/li\u003e\n\u003cli\u003e0-5 V (3-wire)\u003c\/li\u003e\n\u003cli\u003e1-6V\u003c\/li\u003e\n\u003cli\u003e0-10V (3-wire)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10-28 VDC\u003c\/li\u003e\n\u003cli\u003e15-28 VDC (0-10 V output)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-4.5V ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC ±0.5 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ 3 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 K Ohms, min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±0.5% typical, ±1% max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e10 m V\/V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e5 VDC, typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026lt; 5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u0026gt; 1 M Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e~5 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e≤ ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApprovals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.trade.gov\/ce-marking#\" target=\"_blank\" title=\"CE Marking\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/services\/restriction-hazardous-substances-directive-rohs-compliance-services\" target=\"_blank\" title=\"RoHS Compliance\"\u003eRoHS Compliant\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewater pressure monitoring\u003c\/li\u003e\n\u003cli\u003ehydraulic \/ pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eHVAC and refrigeration controls\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/tag\/hydrogen-industrial-gas\/\"\u003ehydrogen\u003c\/a\u003e (316L SS only)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878376988803,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs10-core-sensors-industrial-pressure-transducer-process-solutions-corp.png?v=1763385564"},{"product_id":"cs50-non-incendive-pressure-transducer-50-30000-psi","title":"CS50 Non-Incendive Pressure Transducer, 50-30,000 PSI","description":"The CS50 Non-Incendive Pressure Transducer is a high strength \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure sensor\u003c\/a\u003e for use in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 2 hazardous locations\u003c\/a\u003e. The CS50 features an all welded \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction, offering a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS50 a versatile pressure transducer that's able to operate in some of the harshest conditions. The CS50 is an excellent solution for applications such as \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/tag\/hydrogen-industrial-gas\/\"\u003ehydrogen compression and storage\u003c\/a\u003e, and process control instrumentation. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epressures from 50 to 30,000 PSI\u003c\/li\u003e \u003cli\u003esee \u003ca href=\"https:\/\/psctexas.com\/product\/cs51-non-incendive-low-pressure-transducer-core-sensors\/\"\u003emodel CS51\u003c\/a\u003e for pressures below 50 PSI\u003c\/li\u003e \u003cli\u003eone piece design\u003c\/li\u003e \u003cli\u003eno conduit installation required\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS50 Non-incendive Pressure Transducer\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS50 Non-Incendive Pressure Transducer, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers an integral \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck\u003c\/a\u003e Minifast electrical connection. In combination with a CSA Division 2 Turck cordset and Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. Click here to learn more about the \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast electrical connection here: psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e *We recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.5% BFSL \u003csmall\u003e(\u0026gt;10,000 PSI)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X minimum\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5X or 60,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 176ËF\u003c\/li\u003e \u003cli\u003e-40 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-4 to 176ËF\u003c\/li\u003e \u003cli\u003e-20 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 221ËF\u003c\/li\u003e \u003cli\u003e-40 to 105ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 131ËF\u003c\/li\u003e \u003cli\u003e0 to 55ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP Rating\u003c\/a\u003e\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 minimum\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eElectrical Specifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eLow Power\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e1-5 V\u003c\/li\u003e \u003cli\u003e1-6 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-4.5 V ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 VDC Â±0.5 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign='\"top'\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ 3 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eHazardous Area Approvals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2 Groups A,BC,D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/webstore.ansi.org\/standards\/ul\/ul122701ed2017\" target=\"_blank\" rel=\"nofollow noopener\"\u003eANSI\/UL 122701 Single Seal\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eConfiguration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23705 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\" alt=\"cs50-non-incendive-pressure-transducer-core-sensors-psc-texas-configuration\" width=\"1000\" height=\"367\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of the CS50 Non-incendive Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003enatural gas compression\u003c\/li\u003e \u003cli\u003eoil exploration\u003c\/li\u003e \u003cli\u003eprocess controls\u003c\/li\u003e \u003cli\u003ehydrogen (316L SS only)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878377054339,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs-50-non-incendive-pressure-transducer-core-sensors-process-solutions-corp.png?v=1763385565"},{"product_id":"nivotrack-integrated-magnetic-level-transmitter","title":"NIVOTRACK Integrated, Magnetic Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire integrated transmitter with HART communication\u003c\/li\u003e \u003cli\u003e1 mm resolution\u003c\/li\u003e \u003cli\u003edistance, interface, level measurement\u003c\/li\u003e \u003cli\u003enormal and mini rigid guide tube versions\u003c\/li\u003e \u003cli\u003estainless steel or titanium floats\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eNIVOTRACK Integrated Series Magnetic Level Transmitters\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e NIVOTRACK from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is a magnetic \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e for high accuracy measurements of clean fluids. Its high precision renders the NIVOTRACK suitable for custody transfer measurements. Integrating the transmitter into a \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/\"\u003eprocess control system\u003c\/a\u003e is easy thanks to the intelligent signal processing and communication software as well as the wide of range of accessories offered. \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e A float containing a magnetic disc moves along a guide tube with the specific magnetostrictive wire in it. A pulse generated by the electronics travels along the magnetostrictive wire. At the point the pulse reaches the floatâs magnetic field, a torsion develops. Reflected from the torsion point, the pulse creates an acoustic wave that travels back along the wire. The 4-20 mA output of the transmitter is proportional to the elapsed time between the excitation and detection. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ca href=\"https:\/\/www.nivelco.com\/public\/files\/c3d19471-3114-4a67-8494-a2a6136bc663\/42_NIVOTRACK.mp4\"\u003e\u003cimg class=\"size-medium alignleft\" src=\"https:\/\/www.nivelco.com\/public\/files\/c3d19471-3114-4a67-8494-a2a6136bc663\/42_NIVOTRACK.mp4\" alt=\"magnetic-level-transmitter-nivotrack-nivelco\" width=\"1920\" height=\"1080\"\u003e\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12.5-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003emax. 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1-11.5 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1\", 2\" BSP \/ NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOTRACK Integrated Series Magnetic Level Transmitters Model Line-Up\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version â Standard\u003c\/strong\u003e\u003cem\u003e (MI configurations)\u003c\/em\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version â Mini\u003c\/strong\u003e\u003cem\u003e (MY configurations)\u003c\/em\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMeasured Process Value\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eliquid level, distance\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eNominal Length (L)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3-3.5 m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3-1.5 m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMaterial of the Tube\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1.4571 (316Ti) stainless steel\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Medium Pressure(1)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.5 MPa (25 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.6 MPa (16 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMedium Temperature(1)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eStandard Float Diameter \/ Material(1)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã54 x 60 mm cylindrical \/ 1.4404 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Ã28 x 29 mm \/ 1.4404 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMedium Density\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eÃ54 mm float min. 0.8 g\/cm\u003csup\u003e3\u003c\/sup\u003e; Ã54 mm titanium float min. 0.55 g\/cm\u003csup\u003e3\u003c\/sup\u003e Ã95 mm float min. 0.55 g\/cm\u003csup\u003e3\u003c\/sup\u003e Ã124 mm or Ã95 mm titanium float min. 0.4 g\/cm\u003csup\u003e3\u003c\/sup\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaterial of Wetted Parts\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Stainless steel: 1.4571 (316Ti) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"1\" rowspan=\"2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAnalog\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 4-20 mA (limit values: 3.9-20.5 mA) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eDigital Communication\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eHART (minimum loop resistance: 250 Î©)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eError Indication\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Output signal = 22 mA or 3.8 mA \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eOutput Load\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eRt = (Ut - 12.5 V) \/ 0.02 A, Ut = power supply voltage\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 12.5â36 V DC \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eElectrical Protection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eClass III\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rated\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMass\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.9 kg + measuring probe: 0.6 kg\/m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e2.9 kg + measuring probe: 0.3 kg\/m\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/09\/nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini.jpg\"\u003e\u003cimg class=\"alignnone wp-image-17065 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/09\/nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini.jpg\" alt=\"nivotrack-nivelco-integrated-compact-level-transmitter-measuring-sensor-water-liquids-measurement-process-solutions-corp-mini\" width=\"1800\" height=\"661\"\u003e\u003c\/a\u003e\u003c\/h3\u003e \u003ch3\u003eCommon Uses of NIVOTRACK Integrated Magnetic Level Transmitter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003elevel measurement of liquids, with minimum 25 lb \/ ft\u003csup\u003e3\u003c\/sup\u003e density\u003c\/li\u003e \u003cli\u003elevel monitoring of tanks\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemicals, solvents, hydrocarbons\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy sector\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380101763,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOTRACK-MIA-500-nivelco-integrated-level-transmitter-measuring-sensor-water-liquids-measurement.jpg?v=1763385587"},{"product_id":"nivotrak-compact-series-magnetostrictive-level-transmitter","title":"NIVOTRAK Compact Series, Magnetostrictive Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire compact transmitter\u003c\/li\u003e \u003cli\u003e0.004 inch or 0.04 inch resolution\u003c\/li\u003e \u003cli\u003ewetted parts: stainless steel or plastic\u003c\/li\u003e \u003cli\u003eplug-in graphic display module\u003c\/li\u003e \u003cli\u003e99-point linearization\u003c\/li\u003e \u003cli\u003edistance, level, volume, interface measurement\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eexplosion-proof variants available\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ecustody transfer measurement (OIML R 85)\u003c\/li\u003e \u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e \u003c\/ul\u003e [embed]https:\/\/www.nivelco.com\/public\/files\/a7fef03e-548d-4818-be66-1bb05d2d73b0\/08_NIVOTRACK.mp4[\/embed] \u003ch3\u003eMagnetostrictive Level Transmitter Operating Principles\u003c\/h3\u003e This \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e uses a float containing a magnetic disc moves along a guide tube with the specific magnetostrictive wire in it. A pulse generated by the electronics travels along the magnetostrictive wire. At the point the pulse reaches the floatâs magnetic field, a torsion develops. Reflected from the torsion point, the pulse creates an acoustic wave that travels back along the wire. The 4-20 mA output of this magnetostrictive level transmitter from \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e is proportional to the elapsed time between the excitation and detection. \u003ch3\u003eHART Protocol Connected\u003c\/h3\u003e The instrument with HART output can be connected to a PC using an UNICOMM HART USB modem. Max. 15 normal (non Ex) instruments can be connected to a HART line. Measured values can be visualized and\/or the instruments can be programmed via digital HART communication. EView2 configuration software or NIVISION process visualization software. MultiCONT can handle a maximum of 15 HART capable transmitters (4 Ex-version transmitters). The digital (HART) information is processed, displayed, and if needed, it can be transmitted via RS485 communication line to a PC. Remote programming of the transmitters is also possible. Visualization on PC can be accomplished with NIVISION process visualization software. \u003ch3\u003eNIVOTRACK Compact Series Magnetostrictive Level Transmitter Specifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e12.5-36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 158ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e-40 to 194ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess Pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003emax. 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e0-50 feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4-20 mA, HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP67 (IP68)\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, IEC Ex, OIML R 85\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eNIVOTRACK Compact Series Magnetostrictive Level Transmitter Specifications\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRigid Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eFlexible Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003ePlastic Coated Rigid Probe Version\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMini Version with Rigid Probe\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMeasured Process Value\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e liquid level, distance, volume \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eNominal Length (L)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.5-14.5 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 6.5-50 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.5-10 ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1.5-4.5 ft\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaterial of the Tube\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4571 (316 Ti) stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e PFA coated stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4571 stainless steel \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMax. Medium Pressure (1)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.5 MPa (25 bar g \/ 363 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.6 MPa (16 bar g \/ 232 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.3 MPa (3 bar g \/ 43.5 psi g) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1 MPa (10 bar g \/ 145 psi g)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e -40 to 194ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eStandard Float Diameter \/ Material (2)\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2 x 2.35â cylindrical \/ 1.4404 (316L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 4â ball \/ 1.4435 (316L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 3 x 3.45â cylindrical \/ PVDF \/ PP \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e1 x 1.15â cylindrical 1.4404 (316L)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMaterial of Wetted Parts\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e stainless steel: 1.4571, 1.4404 (316 Ti, 316 L) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e PFA, PVDF, PP \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003estainless steel: 1.4571, 1.4404\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"1\" rowspan=\"3\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAnalog\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e4-20 mA (limit values: 3.9-20.5 mA)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDigital\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e4-20 mA + HART\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eSAP-300 graphic display\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eDamping Time\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eAdjustable 0 to 99 s\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eError Indication\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 22 mA or 3.8 mA or holding \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eOutput Load\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eRt = (Ut-12.5V) \/ 0.02 A, Ut = power supply voltage\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 12.5-36 V DC \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eElectrical Protection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eClass III\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP 67 rated\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eElectric Connection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2x M20x1.5 plastic cable glands for 0.25-0.5 inch cable + 2x NPT 1â2 â internal thread for cable protective pipe terminal block for 0.5-1.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG 20 - AWG 15) wire cross section \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eHousing\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003ePaint coated aluminum or plastic (PBT)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.3.75 lb + m. probe: 0.4 lb\/ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 6.4 lb + m. probe: 0.2 lb\/ft + counter weight 7.7 lb \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 3.75 lb + m. probe: 0.45 lb\/ft \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e3.75 lb + m. probe: 0.4 lb\/ft\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of Magnetostrictive Level Transmitters\u003c\/h3\u003e \u003cul\u003e \u003cli\u003elevel measurement of normal and flammable liquids with minimum 0.4 specific gravity\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemicals, solvents, and hydrocarbons\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eplastic coated version for chemicals\u003c\/li\u003e \u003cli\u003epower plants\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil and energy industry, ATG (Automatic Tanking Gauge)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003ecustody transfer measurement\u003c\/li\u003e \u003cli\u003efuels and gasoline products\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003ePharmaceutical industry\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003eFood industry, alcohols, and beverages\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003einstallation in bypass tubes feasible\u003c\/li\u003e \u003cli\u003esupplementary level transmitter for \u003ca href=\"https:\/\/psctexas.com\/product\/nivoflip-bypass-liquid-level-indicator\/\"\u003eNIVOFLIP magnetic flip indicator\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380134531,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Nivelco_NIVOTRACK-MCA-500-nivotrack-nivelco-magnetostrictive-level-transmitter-measuring-level-sensor.png?v=1763385588"},{"product_id":"nivomag-series-magnetic-float-level-switch","title":"NIVOMAG Series, Magnetic Float Level Switch","description":"\u003cul\u003e \u003cli\u003eOperation without power supply\u003c\/li\u003e \u003cli\u003eMicro-switch separated from the process\u003c\/li\u003e \u003cli\u003eAll wetted parts stainless steel\u003c\/li\u003e \u003cli\u003eSide or top mounting\u003c\/li\u003e \u003cli\u003eFixed or adjustable switch differential\u003c\/li\u003e \u003cli\u003eSubmersible versions\u003c\/li\u003e \u003cli\u003eVarious process connections\u003c\/li\u003e \u003cli\u003eOperational check via optional tester\u003c\/li\u003e \u003cli\u003eFlame-proof variants available\u003c\/li\u003e \u003cli\u003eSIL1 approval\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLiquids with minimum 0.7 specific gravity\u003c\/li\u003e \u003cli\u003eFail-safe and control level switches in closed tanks\u003c\/li\u003e \u003cli\u003eBallast tanks of ships\u003c\/li\u003e \u003cli\u003eChemical industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003ePower plants\u003c\/li\u003e \u003cli\u003eOil industry\u003c\/li\u003e \u003cli\u003eWater industry, water tanks, feedwater tanks\u003c\/li\u003e \u003cli\u003eOverflow protection\u003c\/li\u003e \u003cli\u003eLevel controls\u003c\/li\u003e \u003cli\u003eSupplementary fail safe switch if combined with other devices\u003c\/li\u003e \u003cli\u003eFuel tanks\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eMKK Tester and Counter Flange\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Am MMK tester device can be mounted between the housing and the counter flange.Â The tester is used to check the correct operation of switch without dismantling or true level change. The counter flange is to be welded to the tank. Screws are connected to the housing. \u003ch4\u003eTop and Side Mounting Options\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eSide\u003c\/strong\u003e The hysteresis can be adjusted by positioning the rings on the rod. By positioning the counterweight the different rod lengths can be compensated. \u003cdiv class=\"page\" title=\"Page 5\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eTop\u003c\/strong\u003e The hysteresis can be adjusted between the maximum and minimum values of the range by changing the position of the pins. \u003ch4\u003eNIVOMAG Magnetic Float Level Switch Specifications\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eAmbient temperature\u003c\/th\u003e \u003ctd\u003eâ4â¦+176 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eProcess temperature\u003c\/th\u003e \u003ctd\u003eâ122â¦+482Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eProcess pressure\u003c\/th\u003e \u003ctd\u003eup to 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOutput\u003c\/th\u003e \u003ctd\u003e250 V AC, 10 A NO\/NC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eProcess connection\u003c\/th\u003e \u003ctd\u003eflanges or 2\" thread\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eIngress protection\u003c\/th\u003e \u003ctd\u003eIP65, IP68\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eApprovals\u003c\/th\u003e \u003ctd\u003eATEX, IEC Ex, INMETRO, DNV (Marine), BV (Marine), SIL1\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eNIVOMAG Magnetic Float Level Switch Model Line-Up\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eNIVOMAG\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMK-21\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMK-22\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMK-23\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFixed hysteresis\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAdjustable hysteresis\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eStraight arm\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eL or Z arm\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSide mounted\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eTop mounted\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSubmersible\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eRubber protection sleeve\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFlanged process connection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e X \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eThreaded process connection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eEx version\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eTester\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003eX\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380167299,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/nivomag-magnetic-float-level-switch-measuring-instrumentation-tank-marine-certified-hazloc.png?v=1763385589"},{"product_id":"nivopoint-series-magnetic-level-switch","title":"NIVOPOINT Series, Magnetic Level Switch","description":"\u003cul\u003e \u003cli\u003eOperation without power supply\u003c\/li\u003e \u003cli\u003eReed switch connection\u003c\/li\u003e \u003cli\u003eWetted parts stainless steel or plastic\u003c\/li\u003e \u003cli\u003eUp to 5 switching points\u003c\/li\u003e \u003cli\u003eVertical adjustability of all switching points\u003c\/li\u003e \u003cli\u003eMultiple process connections\u003c\/li\u003e \u003cli\u003eFlame-proof variants available\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLiquids with minimum 0.4 specific gravity\u003c\/li\u003e \u003cli\u003eMulti-point level switch in closed tanks\u003c\/li\u003e \u003cli\u003eFoaming liquids, chemicals with dense vapor or gas layer above the surface\u003c\/li\u003e \u003cli\u003eChemical, oil industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003ePower plants\u003c\/li\u003e \u003cli\u003eFor controlling pumps, valves\u003c\/li\u003e \u003cli\u003eLevel detection of aggressive liquids\u003c\/li\u003e \u003cli\u003eLevel switching of explosive liquids\u003c\/li\u003e \u003cli\u003eWater industry\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eUsing a Magnetic Float Level Switch\u003c\/h4\u003e NIVOPOINT magnetic float level switches work on the basis of the interaction of the built-in magnet in the float and the reed switches in the probe. The float of NIVOPOINT level switch devices moves alongside the probe tube tracking the level of the measured liquid and activating the reed switches. When the float moves ahead the reed switches, it changes the default state (NO or NC) of the reed switches, which stay in self-holding state with the help of opposite polarized magnets next to the reed switches. When the liquid level decreases, the float moves ahead the reed switches again, breaks off the self-holding state and restores the previous state of the reed switches. \u003ch4\u003eMagnetic Floats and Reeds for Level Switches\u003c\/h4\u003e By tracking the level, the magnetic float activates the reed switch in the probe. The reed switch opens or closes according to the position of the magnetic float. The default state is meant with bottom positioned float, the normally opened or closed state of the reed switch can be changed by the inversion of the float. The mini type NIVOPOINT level switches do not contain biasing magnets. \u003ch4\u003eInstalling a Magnetic Float Level Switch\u003c\/h4\u003e A NIVOPOINT level switch equipped with Ã52 mm cylindrical float can be installed into the tank through a 2\" BSP process connection. Units with larger floats need to be flanged unless a mounting of the float by accessing the interior of the tank is allowed. Mini type level switches may feature 1\/4\" BSP or 2\" BSP connections. These level switches are to be mounted into a tank from inside and fixed with a nut from outside. \u003ch4\u003eNIVOPOINT Magnetic Float Level Switch Specifications\u003c\/h4\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eAmbient temperature:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ40â¦+203 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess temperature:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eâ40â¦+302 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess pressure:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eup to 363 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e250 V AC, 3A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess connection:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e1\", 2\" or flanges\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eIngress protection:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eIP67, IP68\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals:\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003eATEX, BV (Marine)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cdiv title=\"Page 3\"\u003e \u003ch4\u003eNIVOPOINT Series Magnetic Float Level Switch Model Line-Up\u003c\/h4\u003e \u003c\/div\u003e \u003cdiv class=\"page\" title=\"Page 3\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eStandard type\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003ePlastic coated type\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eExplosion-proof type\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMini type\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eInsertion length\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.25 m...3 m \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e0.1 m...0.5 m\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMaterial of wetted parts\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4404 float \/ 1.4571 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e PVDF or PP float \/ PFA coated guiding tube \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4404 float \/ 1.4571 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1.4404 float \/ 1.4571 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMaximum process pressure\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 2.5 MPa (25 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.5 MPa (5 bar) \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e2.5 MPa (25 bar)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMinimum medium density\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.8 kg\/dm\u003csup\u003e3\u003c\/sup\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.4 \/ 0.7 kg\/dm\u003csup\u003e3\u003c\/sup\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.8 kg\/dm\u003csup\u003e3\u003c\/sup\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMedium temperature\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e -40â¥ËF...302ËF -40ËF...176ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"1\" rowspan=\"2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e see: temperature data for Ex versions table below \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e -40ËF...248ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eAmbient temperature\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e -40Â°F...212ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e-40Â°F...158ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1...5 pcs reed-switches, one connecting point of each is common, NO\/NC \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 1...3 pcs reed-switches, NO or NC depending on float orientation \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eSwitching rate\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 120 W \/ VA, 250 V AC\/DC, 3 A \/ reed relay, summary max. 9 A \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e120 W\/VA 250 V AC\/DC max. 3 A\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSwitching point\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e see: auxiliary data of the order codes table \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 40 mm Â± 3 mm from the bottom of the protection tube \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eSwitching differential\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u0026lt; 10 mm\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDistance between reed-switches\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Minimum 110 mm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\" colspan=\"1\" rowspan=\"2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eElectrical connection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Cable gland M 20x1.5, Cable gland M 20x1.5, cable outer Ã: 6...12 mm cable outer Ã: 9.5...10 mm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"1\" rowspan=\"2\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e0.5 m long, 2 x 0.75 mm\u003csup\u003e2\u003c\/sup\u003e\/ cable with silicon sealing (outer Ã: 5 mm)\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eterminal, 0.5 ... 2.5 mm\u003csup\u003e2\u003c\/sup\u003e wire cross section\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eProcess connection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e as per order code \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eGasket\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd colspan=\"4\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eKlingerit â Klingerit\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eElectrical protection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Class I \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Class II \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eIngress protection\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e IP 65 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eIP 68\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e â \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e II 2 G EEx d IIC T3...T6 \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e Bureau Veritas \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eDimension of the housing\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 116 x 80 x 65 mm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 124 x 80 x 65 mm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003eâ\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\" colspan=\"2\" rowspan=\"1\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.4 kg + 0.3 kg\/fm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 0.45 kg + 0.3 kg\/fm \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e0.15 kg + cable: 0.05 kg\/fm\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eTemperature Data for Ex D Float Level Switch Model\u003c\/h4\u003e \u003cdiv class=\"page\" title=\"Page 4\"\u003e \u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e\n\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eClass\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eT6\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eT5\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eT4\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eT3\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMax. ambient temperature from -4ËF\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 176ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 203ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 185ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 158ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cstrong\u003eMax. medium temperature from -4ËF\u003c\/strong\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 185ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 212ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e 275ËF \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003ctd\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cp style=\"text-align: center;\"\u003e302ËF\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878380200067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOPOINT-Magnetic-Level-Switch-water-hazloc-hazardous-liquid-measurement-measuring-level-monitoring.jpg?v=1763385590"},{"product_id":"levelrat-non-fouling-submersible-level-transmitter","title":"LevelRat, Non-Fouling Submersible Level Transmitter","description":"\u003cp\u003eThe LevelRat submersible level transmitter provides an infinite combination of level ranges, output options, and cable lengths. This ensures the perfect fit for monitoring equipment. These level transmitters are frequently paired with a SCADA, PLC, compatible display, or control system for use as a water level indicator or controller. Submersible level transmitters, from KELLER America, offer high accuracy down to 900 feet.\u003c\/p\u003e\n\u003cp\u003eIn addition, they have built-in lifetime lightning protection and standard three day shipping. Known for their superior reliability, reasonable cost, and ready availability, Keller submersible level transmitters feature small size and integral signal conditioning. Their design simplifies installation anywhere quality liquid level sensors are necessary.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eNon-Fouling Submersible Level Transmitter for Lift Stations and Wastewater Applications\u003c\/h2\u003e\n\u003cp\u003eWith a design for extending service in sewage lift station environments, the LevelRat features a wide sensing diaphragm, yet small overall size. Many competing models feature a fragile, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.teflon.com\/en\" target=\"_blank\" title=\"Teflon\"\u003eTeflon-coated\u003c\/a\u003e rubber diaphragm. However, the LevelRat incorporates a monolithic diaphragm that combines the non-stick quality of Teflon with superior toughness and abrasion resistance. The LevelRat utilizes piezoresistive silicon measurement technology and KELLER’s state-of-the-art, microprocessor-based signal conditioning circuitry.\u003c\/p\u003e\n\u003cp\u003eThis design and construction provides outstanding accuracy and reliability over a wide temperature range. Perfect for pump control applications, the LevelRat is compatible with any standard 2-wire, 4-20 mA current loop, or 3-wire voltage systems. The RS485 interface allows users to scale the analog output to any necessary range within the standard pressure range. The LevelRat typically suspends into the liquid by a standard PE-jacket cable that is self-supporting and features a vent. Optional Hytrel or Tefzel-jacket cables are available if the installation should require greater protection against chemical interaction.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFeatures of the LevelRat Submersible Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eLevelRat's guaranteed lightning protection makes this transmitter ideal for installation in areas prone to chronic damage due to transients from lightning. Models with 4-20mA analog output include a guarantee of lightning protection at no additional cost. This feature protects the LevelRat from fast-rising transients and carries a lifetime guarantee against damage from electrical surge.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA models include guaranteed lightning protection at no additional cost\u003c\/li\u003e\n\u003cli\u003e16-bit internal digital error correction for cost-effective low Total Error Band (TEB)\u003c\/li\u003e\n\u003cli\u003e316L stainless construction standard - optional titanium for severe applications\u003c\/li\u003e\n\u003cli\u003enon-fouling diaphragm with superior resistance to puncture\u003c\/li\u003e\n\u003cli\u003e2-year warranty covers defects in materials and workmanship\u003c\/li\u003e\n\u003cli\u003euser-rangeable analog output ensures compatibility as requirements change\u003c\/li\u003e\n\u003cli\u003eRS485 modified-\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eMODBUS\u003c\/a\u003e compatible interface allows up to 128 transmitters on a single bus\u003c\/li\u003e\n\u003cli\u003estandard dual (analog \u0026amp; RS485) outputs simplify interface to controls, data collection, and telemetry systems\u003c\/li\u003e\n\u003cli\u003eARRA Section 1605 Compliant\u003c\/li\u003e\n\u003cli\u003estandard 3-day lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePressure Ranges - Relative\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003einfinite between 0-5 and 0-100ftWC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eAccuracy, Static at 77˚F (25°C)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.5% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eAccuracy, Total Error Band\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e1% BR TEB (see data sheet for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eStorage \/ Operating Temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e14 to 140˚F (-10 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Ratings for Industrial Instrumentation\" rel=\"noopener\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003ch2 style=\"text-align: left;\"\u003eAssembled in the USA\u003c\/h2\u003e\n\u003cp\u003eThe LevelRat is assembled in the USA to customer specifications, including custom pressure ranges and cable lengths. Most orders ship in 3 business days or less.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eProduct Comparison\u003c\/h2\u003e\n\u003ch2\u003e\u003csmall\u003e\u003csmall\u003e\u003csmall\u003eOur non-fouling submersible level transmitter is interchangeable with many submersible transmitters and best of all, it’s assembled in the USA, in-stock, and offers a standard delivery of 3 business days or fewer. Some of the similar products include:  KPSI 750, AST4520, NOSHOK 613, PMC VersaLine VL2000, GP:50 311-M351, Dwyer PBLT2, PBLTX, SBLT2, SBLTX, MBLT, and FBLT, YSI WL430, FOGRod, Endress Hauser E+H Micropilot FMR20, Siemens SITRANS LH300, and more.\u003c\/small\u003e\u003c\/small\u003e\u003c\/small\u003e\u003c\/h2\u003e","brand":"KELLER","offers":[{"title":"Default Title","offer_id":45878380789891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/levelrat-keller-non-fouling-submersible-level-transmitter-for-lift-stations-wastewater-treatment-facilities-process-solutions-corp-shop-online-in-stock.png?v=1763385598"},{"product_id":"acculevel-high-accuracy-submersible-level-transmitter","title":"Acculevel, High Accuracy Submersible Level Transmitter","description":"\u003cp\u003eThe Acculevel high accuracy submersible level transmitter provides an infinite combination of level ranges, output options, and cable lengths. This ensures the perfect fit for monitoring equipment. They are frequently paired with a SCADA, PLC, compatible display, and\/or control system for use as a water level indicator or controller.\u003c\/p\u003e\n\u003cp\u003eThese submersible level transmitters, from KELLER America, offer high accuracy down to 900 feet, built in lifetime lightning protection, and standard three day shipping. Known for their superior reliability, reasonable cost, and ready availability, our submersible level transmitters feature small size and integral signal conditioning. This simplifies installation anywhere quality liquid level sensors are needed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003etemperature compensation\u003c\/li\u003e\n\u003cli\u003euser rearrangeable analog output\u003c\/li\u003e\n\u003cli\u003edual output: RS485 \/ \u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\" title=\"Modbus Protocol\"\u003eModbus\u003c\/a\u003e, 4-20mA\u003c\/li\u003e\n\u003cli\u003eoperates in 0-900 feet of water\u003c\/li\u003e\n\u003cli\u003ecustom pressure ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch2\u003eAcculevel High Accuracy Submersible Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThis exceptional instrument has certification to \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.nsf.org\/knowledge-library\/nsf-ansi-standard-61-drinking-water-system-components-health-effects\" target=\"_blank\" title=\"NSF - ANSI Standard 61\"\u003eNSF\/ANSI 61\u003c\/a\u003e and 372 standards for use in drinking water applications. And, on models with 4-20mA analog output, the Acculevel submersible level transmitter also includes a guarantee for lightning protection. This internal circuit comes at no additional cost and provides a lifetime warranty against damage from voltage surge.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eThermally-Compensated, Custom Range, Dual Output Submersible Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe Acculevel provides standard features that far exceed those of comparably priced transmitters, including standard ±0.25% FS or optional ±0.1% Total Error Band (TEB) accuracy. This level transmitter is approved to NSF\/ANSI 61 and 372 standards for water quality and includes KELLER America’s guaranteed lightning protection, making the Acculevel an outstanding value for liquid level measurement. The ability of the Acculevel to provide this level of performance over a wide range of operating conditions makes it ideal for an equally wide range of applications. Common applications include drinking water, stream and reservoir level, environmental monitoring, tank level, wastewater, etc.. It's also ideal for installations in areas prone to chronic damage due to transients from lightning.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePressure Ranges - Relative\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003einfinite between 0-3 and 0-900ftWC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eAccuracy, Static at 77˚F (25˚C)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003estandard: 0.1% FS optional: 0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eAccuracy, Total Error Band\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eStandard: 0.25% BR TEB Optional: 0.1% BR TEB (see data sheet for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eStorage and Operating Temperatures\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e14 to 140˚F (-10 to 60˚C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP68 rating\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/kelleramerica.com\/media\/nsf_61_372.png\" alt=\"acculevel-high-accuracy-submersible-level-transmitter-keller-kpsi-water-level-sensing\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ecertification to NSF\/ANSI 61 and 372 standards for use in drinking water applications\u003c\/li\u003e\n\u003cli\u003e4-20mA models include a guarantee for lightning protection at no additional cost\u003c\/li\u003e\n\u003cli\u003e16-bit internal digital error correction for cost-effective low Total Error Band (TEB)\u003c\/li\u003e\n\u003cli\u003e316L stainless construction standard - optional titanium for severe applications\u003c\/li\u003e\n\u003cli\u003e2-year warranty covers defects in materials and workmanship\u003c\/li\u003e\n\u003cli\u003euser-rangeable analog output ensures compatibility as requirements change\u003c\/li\u003e\n\u003cli\u003eRS485 modified-MODBUS compatible interface allows up to 128 transmitters on a single bus\u003c\/li\u003e\n\u003cli\u003estandard dual (analog \u0026amp; RS485) outputs simplify interface to controls, data collection, and telemetry systems\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.acquisition.gov\/far\/subpart-25.6\" target=\"_blank\" title=\"America Recovery and Reinvestment Act Compliant\"\u003eARRA Section 1605 Compliant\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003estandard 3-day lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eAssembled in the USA\u003c\/h2\u003e\n\u003cp\u003eThe Acculevel is assembled in the USA to customer specifications, including custom pressure ranges and cable lengths. Most orders ship in 3 business days or fewer.\u003c\/p\u003e","brand":"KELLER","offers":[{"title":"Default Title","offer_id":45878380822659,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/acculevel-keller-submersible-level-transmitters-wastewater-tank-level-measurement-lift-station-kpsi-process-solutions-corp.png?v=1763385599"},{"product_id":"levelgage-drinking-water-level-transmitter","title":"Levelgage, Drinking Water Level Transmitter","description":"The Levelgage drinking water \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/submersible-level-transmitters\"\u003elevel transmitter\u003c\/a\u003e provides an infinite combination of level ranges, output options, and cable lengths. This ensures the perfect fit for monitoring equipment. They are frequently paired with a SCADA, \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/\"\u003ePLC\u003c\/a\u003e, compatible display, and\/or control system for use as a \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003ewater level indicator or controller\u003c\/a\u003e. Submersible level transmitters, from \u003ca href=\"https:\/\/psctexas.com\/brand\/keller\/\"\u003eKELLER America\u003c\/a\u003e, offer high accuracy down to 900 feet, built in lifetime \u003ca href=\"https:\/\/psctexas.com\/product-category\/lightning-protection\/\"\u003elightning protection\u003c\/a\u003e, and standard three day shipping. Known for their superior reliability, reasonable cost, and ready availability, our submersible level transmitters feature small size and integral signal conditioning. They simplify installation anywhere quality liquid level sensors are necessary. \u003ch3 style=\"text-align: left;\"\u003eCustom Range, Analog Drinking Water Level Transmitter\u003c\/h3\u003e The Levelgage provides standard features that far exceed those of comparably priced instruments, including standard Â±1% FS Total Error Band (TEB) or optional Â±0.5% FS TEB accuracy. This level transmitter offers \u003ca href=\"https:\/\/www.nsf.org\/knowledge-library\/nsf-ansi-standard-61-drinking-water-system-components-health-effects\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNSF\/ANSI 61\u003c\/a\u003e and 372 standards certification for water quality. Additionally, it includes KELLER Americaâs guarantee for lightning protection, making the Levelgage an outstanding value for liquid level measurement. The ability of the Levelgage to provide this level of sustainable performance over a wide range of operating conditions makes it ideal for an equally wide range of applications. Common applications include \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003edrinking water, stream and reservoir level, environmental monitoring, tank level, and wastewater\u003c\/a\u003e. It's also ideal for installations in areas prone to chronic damage due to transients from lightning strike. \u003ch3 style=\"text-align: left;\"\u003e\n\u003cimg class=\"alignright \" src=\"https:\/\/kelleramerica.com\/media\/nsf_61_372.png\" alt=\"levelgage-submersible-level-transmitter-drinking-potable-water-safe-level-measurement\" width=\"125\" height=\"116\"\u003eFeatures of the Levelgage\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eNSF\/ANSI 61 and 372 certified construction for use in drinking water applications\u003c\/li\u003e \u003cli\u003e4-20mA models include a guarantee of lightning protection at no additional cost\u003c\/li\u003e \u003cli\u003e16-bit internal digital error correction for cost-effective low Total Error Band (TEB)\u003c\/li\u003e \u003cli\u003e316L stainless steel construction\u003c\/li\u003e \u003cli\u003e2-year manufacturer warranty covers defects in materials and workmanship\u003c\/li\u003e \u003cli\u003eindustry standard analog outputs simplify interface to controls, data collection, and telemetry systems\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.acquisition.gov\/far\/subpart-25.6\" target=\"_blank\" rel=\"nofollow noopener\"\u003eARRA Section 1605 Compliant\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003estandard 3-day lead time\u003c\/li\u003e \u003c\/ul\u003e Additionally, models equipped with 4-20mA analog output include a guarantee of lightning protection at no additional cost. This feature protects the Levelgage from fast-rising transients and carries a lifetime guarantee against damage from electrical surge. \u003ch3 style=\"text-align: left;\"\u003eSpecifications of this Drinking Water Level Transmitter\u003c\/h3\u003e \u003ctable class=\"table table-striped table-bordered\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePressure Ranges - Relative\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eInfinite between 0-3 and 0-900ftWC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy, Static at 77ËF (25Â°C)\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.25% FS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAccuracy, Total Error Band\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003estandard: 1% BR TEB optional: 0.5% BR TEB (see data sheet for details)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eStorage \/ Operating Temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e14 to 144ËF (-10 to 60ËC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProtection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIP68\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003e rating\u003c\/a\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3 style=\"text-align: left;\"\u003eAssembled in the USA\u003c\/h3\u003e The Levelgage is assembled in the USA to customer specifications, including custom pressure ranges, \u003ca href=\"https:\/\/psctexas.com\/product-category\/cables\/\"\u003ecable lengths\u003c\/a\u003e, and your choice of industry standard analog outputs (current or voltage). Most orders ship in 3 business days or less.","brand":"KELLER","offers":[{"title":"Default Title","offer_id":45878380888195,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/levelgage-submersible-level-transmitter-keller-kpsi-style-wastewater-tank-level-measurement.png?v=1763385600"},{"product_id":"power-on-uninterruptible-power-supply-ups","title":"POWER-ON, Uninterruptible Power Supply (UPS)","description":"The system uses sealed lead acid batteries for backup power and incorporates all the latest Uninterruptible Power Supply (UPS) features and technology for maximum performance. It is ideal for \"point of use\" implementation with relatively small or individual controller loads. It is also available for use in either in \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEC Classified or Unclassified\u003c\/a\u003e areas. Furthermore, purge options and other third-party certifications are available. \u003ch3 style=\"text-align: left;\"\u003eHighly Customizable Features for POWER-ON Uninterruptible Power Supply\u003c\/h3\u003e Battery selection provides for a wideÂ range of backup time. Supported 12 VDCÂ battery sizes are between 3.9 and 150 Ah.Â A typical application using 100 Ah batteriesÂ results in a battery backup time ofÂ about 9 hours at 22.5 Volts \/ 10 ampsÂ load. Electrical design provides for segregationÂ of critical and non-critical loadsÂ making backup times as long as possibleÂ while using the same pair of power supplies. \u003ch3 style=\"text-align: left;\"\u003eRedundant Battery Back Up for Critical Processes\u003c\/h3\u003e \u003cimg class=\"alignright wp-image-11976\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/12\/UPS_Power-300x198.jpg\" alt=\"power-on-ups-industrial-uninterruptible-power-supply-redundant-battery-back-up-process-solutions-corp-texas\" width=\"500\" height=\"330\"\u003e Standard primary power can be 120 orÂ 240VAC and output voltage is adjustable. \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eredundant battery backup for critical process control, monitoring, and alarm systems\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003evariety of backup times based on load and battery selection\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003euninterrupted power can be supplied to \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/\"\u003econtroller\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/product-category\/connectivity\/\"\u003ecommunications electronics\u003c\/a\u003e, sensors, as well as valves\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eallows process to continue running normally despite loss of primary power\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eadvanced diagnostics and alarming provides confidence that the system is ready to respond to power outages and also brown-outs\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esurge protection and monitoring for faults; a contact is available for monitoring and alarming\u003c\/li\u003e \u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878380986499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/power-on-ups-unterruptible-power-supply-process-solutions-corp-square.png?v=1763385603"},{"product_id":"psc6000-operation-controller-with-touch-screen-hmi","title":"PSC6000 Operation Controller with Touch Screen HMI","description":"The PSC6000 flow control system is preprogrammed with standard features, making this a great plug-and-play option for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/manufacturing\/\"\u003emanufacturers\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/education-and-research\/\"\u003euniversities and research or analytical labs\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/food-and-beverage\/\"\u003efood and beverage producers\u003c\/a\u003e, cosmetic and \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/pharmaceuticals-and-medical\/\"\u003epharmaceutical production\u003c\/a\u003e, and more. Since there is no programming required, this operation controller is ideal for users with little or no programming experience. In addition to standard features, our engineers can program custom parameters and functions on the PSC6000 Operations Controller, depending on specific customer and application requirements. Standard features include: \u003cul\u003e \u003cli\u003eflow rate\u003c\/li\u003e \u003cli\u003etotalizer\u003c\/li\u003e \u003cli\u003eset point\u003c\/li\u003e \u003cli\u003ebatch operations\u003c\/li\u003e \u003cli\u003eeasy to access connections\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eEthernet Enabled Flow Control System\u003c\/h3\u003e In addition to including both digital and analog output options, the built-in HMI is \u003ca href=\"https:\/\/psctexas.com\/tag\/ethernet-enabled\"\u003eethernet enabled\u003c\/a\u003e, which allows remote access and monitoring along with data logging. Moreover, this flow control system is equipped with a USB port and Micro SD card slot, so you can save your process data at any time. The touch screen interface offers 640x480 high-resolution resistive touch and isÂ programmed to be user-friendly. Also, it includes 32,000 colors and support for multiple languages.\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/mini-CORI-FLOW-ML120.jpg\"\u003e\u003cimg class=\"size-medium wp-image-1624 alignright\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2018\/05\/mini-CORI-FLOW-ML120-300x226.jpg\" alt=\"mini-CORI-FLOW-meter-bronkhorst-flow-instrumentationML120\" width=\"300\" height=\"226\"\u003e\u003c\/a\u003e The PSC6000 uses \u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"noopener\"\u003eModbus\u003c\/a\u003e to communicate with and control flow instrumentation such as \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eflow meters and controllers manufactured by Bronkhorst\u003c\/a\u003e. Our most popular choice is the \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-coriolis-mass-flow-meters-controllers\/\"\u003eMini CORI-FLOW\u003c\/a\u003e, which a \u003ca href=\"https:\/\/psctexas.com\/product-tag\/compact-design\"\u003ecompact\u003c\/a\u003e, highly accurate \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis flow meter\u003c\/a\u003e that is capable of handling both \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/gas-flow\"\u003egas\u003c\/a\u003e or \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\"\u003eliquid flows\u003c\/a\u003e. Also available is theÂ \u003ca href=\"https:\/\/psctexas.com\/product\/mini-cori-flow-ex-d-coriolis-mass-flow-meters-controllers-hazloc\/\"\u003eMini CORI-FLOW Ex d Series\u003c\/a\u003e, which is suitable for \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e.   \u003ch3\u003eUses of the PSC6000 Operation Controller\u003c\/h3\u003e Since it features numerous data logging functions, the PSC6000 is ideal for low flow processes that require record keeping. In addition to helping minimize waste of raw materials, this operations controller is great for optimizing low flow applications, including continuous flow processes. Also, with Batch Operation programming built-in, this flow control unit is sure to keep production consistent between batches and helps when scaling batch size. \u003ch3\u003eApplications Requiring Precise Low Flow Process Control\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUniversities, Research Labs and Analytical Laboratories \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-solution-for-hydrogen-storage\/\"\u003eHydrogen Storage\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-role-of-flow-control-in-hydrogen-production\"\u003eHydrogen Production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-gas-flow-control-for-analytical-instruments\/\"\u003eStable Gas Flow for Analytical Instrumentation\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/benchtop-bioreactors-and-gas-flow-control\"\u003eReliable Biological Growth in Benchtop Bioreactors\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\/\"\u003eVaccine research\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-mass-flow-controller-can-support-in-the-pharmaceutical-industry\/\"\u003ePharmaceutical research\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-control-in-gas-chromatography\/\"\u003eFlow Control in Gas Chromatography processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/calibrating-gas-chromatographs-with-gas-flow-controllers\"\u003eGas Chromatograph calibrations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-to-improve-your-gas-chromatography-analysis\/\"\u003eImproving Gas Chromatography analysis\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/inductively-coupled-plasma-icp-for-environmental-analysis\"\u003eInductively Coupled Plasma for Environmental Analysis\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/low-flow-control-for-corrosion-protection\/\"\u003eProtection against Corrosion\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eManufacturers \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-and-fast-gas-flow-control-for-vacuum-deposition\/\"\u003eVacuum Deposition processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-dosing-with-flow-meters\/\"\u003eLiquid Dosing applications\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/best-dye-dosing-systems\/\"\u003eDye Dosing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/metering-pump-performance-improved-with-flow-meters\"\u003eImproving Metering Pump performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-can-you-improve-your-dosing-pump-performance-with-flow-meters\/\"\u003eImproving Dosing Pump performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003eCommon Flow Meter and Dosing Pump combinations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/dosing-pump-control-for-improved-batching\/\"\u003eBatch Production using Dosing Pumps\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\/\"\u003emRNA Vaccine production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/aeration-in-fish-farming\"\u003eAeration in Fish Farming\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/mass-flow-meter-to-enhance-water-processing\"\u003eReliable Water Treatment processes\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/vapor-and-liquid-flow-control-for-aseptic-packaging\"\u003eLiquid Control in Aseptic Packaging\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-flow-controllers-for-bacterial-growth-in-bioreactors\/\"\u003eFermented Food and Drink production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meters-in-the-food-industry\/\"\u003eIngredient Dosing in Foods and Beverages\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/the-importance-of-flow-control-in-chocolate-production\"\u003eIngredient Dosing in Chocolate production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/what-role-do-flow-meters-play-in-processing-sugar-beets\"\u003eProcessing Sugar Beets\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/camping-applications-that-are-made-possible-with-mass-flow-control\/\"\u003eManufacturing of supplies for Camping\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-control-for-air-duct-leakage-test\/\"\u003eAir Duct Leakage Testing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/space-suit-testing\"\u003eTesting of Space Suits\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/accurate-dosing-of-release-agent\/\"\u003eManufacturing using Plastic Moulds\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/use-of-mass-flow-meters-in-the-automotive-industry\"\u003eManufacturing of Automobiles\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/gas-mixing-chambers-for-homogeneous-gas-mixtures\/\"\u003eBlending Homogeneous Gas Mixtures\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-supply-using-a-pressure-vessel\"\u003eLiquid Supply using a Pressure Vessel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/catalytic-treatment-of-volatile-organic-compounds\/\"\u003eCatalytic Treatment of VOCs\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/controlled-co2-supply-for-algae-cultivation\"\u003eCO\u003csmall\u003e2\u003c\/small\u003e Production for Algae Cultivation\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/stable-and-fast-gas-flow-control-for-vacuum-deposition\"\u003eVacuum Deposition by Reactive Sputtering\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878381052035,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Operation-Controller-PSC-6000-Texas-Flow-Control-e1631024292675.png?v=1763385605"},{"product_id":"kayden-classic-800-series-switch-and-transmitter","title":"Kayden CLASSIC 800 Series, Switch and Transmitter","description":"\u003cp\u003eThe CLASSIC 800 Series features switches and transmitters for flow, level, interface, and temperature process control. Each model has a precision welded, highly accurate stainless steel thermal sensor. The \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 800 Series is ideal for liquids, gases, and slurries in clean or dirty processes. Options for process connections include: raised face, RTJ flange, threaded, or retractable packing glands. In addition, all Kayden CLASSIC models feature a rugged flameproof enclosure with blind or lens cover options. Its advanced digital electronics will revolutionize the way you monitor and control your process.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e\n\u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e\n\u003cli\u003etemperature compensation\u003c\/li\u003e\n\u003cli\u003euniversal power 12-24 VDC and 115-230 VAC standard\u003c\/li\u003e\n\u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e\n\u003cli\u003e4-20 mA analog output\u003c\/li\u003e\n\u003cli\u003esmart heater function for power economy and increased heater life\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKayden CLASSIC 800 Series Model Line Up\u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003eKayden CLASSIC 810 - Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections - MNPT\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1\/2 inch, 3\/4 inch, 1.0 inches, 1 1\/4 inches, 1 1\/2 inches, 2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-812-flanged-thermal-sensor-flow-meter-level-switch-and-transmitter-interface\/\"\u003eKayden CLASSIC 812 - Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCRN\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814 - Flanged Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eretractable packing gland, raised face, or RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816 - Threaded Retractable Packing Gland\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethreaded retractable packing gland (1\" MNPT)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830 - In-Line Threaded\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832 - In-Line Flanged\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003eProcess Connections\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eraised face, RTJ flange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eSingle Seal\u003c\/li\u003e\n\u003cli\u003eNACE\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eConfiguration Options for the Kayden CLASSIC 800 Series*\u003c\/h3\u003e\n\u003cp\u003e*options vary by model selection\u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow\u003c\/li\u003e\n\u003cli\u003elevel\u003c\/li\u003e\n\u003cli\u003einterface\u003c\/li\u003e\n\u003cli\u003etemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eProcess Connections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" FNPT\u003c\/li\u003e\n\u003cli\u003eflanged in-line\u003c\/li\u003e\n\u003cli\u003e MNPT\n\u003cul\u003e\n\u003cli\u003e1\/2 inch\u003c\/li\u003e\n\u003cli\u003e3\/4 inch\u003c\/li\u003e\n\u003cli\u003e1 inch\u003c\/li\u003e\n\u003cli\u003e1-1\/4 inches\u003c\/li\u003e\n\u003cli\u003e1-1\/2 inches\u003c\/li\u003e\n\u003cli\u003e2 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 to 3.5 inches Tri-Clamp\n\u003cul\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003cli\u003esanitary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eretractable packing glands\n\u003cul\u003e\n\u003cli\u003ethreaded (1” MNPT)\u003c\/li\u003e\n\u003cli\u003eflanged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSanitary Tri-Clamp Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eFlanged Style\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eper flange rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h4\u003e\n\u003cp\u003eStandard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1.2 inches (3 cm)\u003c\/li\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003cli\u003e9 inches (23 cm)\u003c\/li\u003e\n\u003cli\u003e12 inches (30 cm)\u003c\/li\u003e\n\u003cli\u003e18 inches (45 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKayden CLASSIC 828 (Sanitary)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 inches (5 cm)\u003c\/li\u003e\n\u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e\n\u003cli\u003e4 inches (10 cm)\u003c\/li\u003e\n\u003cli\u003e6 inches (15 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCustom Lengths\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e\n\u003cli\u003eKayden CLASSIC model dependent: minimum 1.2 inches (3 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eInput Power Options\u003c\/h4\u003e\n\u003cp\u003eUniversal Power Standard\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12-24 VDC\u003c\/li\u003e\n\u003cli\u003e115-230 VAC\u003c\/li\u003e\n\u003cli\u003e50-60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConsumption\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emaximum: 6.0 watts (fully configured)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4-20 mA current loop\u003c\/li\u003e\n\u003cli\u003etwo (2) independent SPDT sealed relay contacts\n\u003cul\u003e\n\u003cli\u003erated at 4 amps resistive 230 VAC or 30 VDC maximum\u003c\/li\u003e\n\u003cli\u003eindividually adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAccuracy\u003c\/h4\u003e\n\u003cp\u003eFlow Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±1% set point velocity over operating range of ±50˚F (±28˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLevel Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±0.25 inches (±0.64 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResponse Time\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eapproximately 0.5 to 30 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRemote Electronics Options\u003c\/h4\u003e\n\u003cp\u003eMaximum Recommended \u003ca href=\"https:\/\/psctexas.com\/product-category\/cables\/\"\u003eCable Length\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200 feet (60 meters)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCable Type\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 AWG minimum\u003c\/li\u003e\n\u003cli\u003etwisted pairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHeater Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003efield adjustable to optimize performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStart Up Bypass Timer\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable for 0 to 100 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e via RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Pressure (Maximum)\u003c\/h4\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 MPa (3500 psig) dependent on Kayden CLASSIC model and material of construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTemperature Range (Sensor)\u003c\/h4\u003e\n\u003cp\u003eContinuous Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-50 to 392˚F (-45 to 200˚C)\u003c\/li\u003e\n\u003cli\u003e-40 to 320˚F (-40 to 160˚C) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectronics\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-67˚F to 149˚F (-55˚C to 65˚C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: For temperatures above 149˚F (65˚C), electronics must be remotely mounted. Storage\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Kayden CLASSIC models should be stored in a clean and dry environment between -34.5 to 140˚F (-30 to 60˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnclosure Material\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ecopper-free aluminum (does not exceed 0.4% copper)\u003c\/li\u003e\n\u003cli\u003epowder coated polyester TGIC (polyester triglycidyl isocyanurate)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4\u003c\/a\u003e \/ Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1” FNPT conduit connection\u003c\/li\u003e\n\u003cli\u003ebuna o-ring on cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConduit Connection Cover\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWetted Materials\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e - standard\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e grade 2\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e316\/316L stainless steel with nickel braze [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-830-threaded-in-line-flow-level\/\"\u003eKayden CLASSIC 830\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-832-flanged-in-line-flow-switch-transmitter\/\"\u003eKayden CLASSIC 832\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003ehighly saturated nitrile (pressure seal) [\u003ca href=\"https:\/\/psctexas.com\/product\/kayden-classic-814-flanged-retractable-packing-gland\/\"\u003eKayden CLASSIC 814\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/classic-816-flow-interface-level-switch-and-transmitter\/\"\u003eKayden CLASSIC 816\u003c\/a\u003e only]\u003c\/li\u003e\n\u003cli\u003eother wetted material options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 800 Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e\n\u003cli\u003e4-20 mA\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/modbus.org\" target=\"_blank\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003erated:\n\u003cul\u003e\n\u003cli\u003e120 Vac max\u003c\/li\u003e\n\u003cli\u003e30 Vdc max\u003c\/li\u003e\n\u003cli\u003e4A max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, Insertion Style\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 3.0 feet\/second (0.003 to 0.9 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 to 5.0 feet\/second (0.003 to 1.5 meters\/second)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.25 to 254 sfps (0.076 to 77 smps)\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSwitch Point Range, In-Line Models\u003c\/h4\u003e\n\u003cp\u003eWater-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.015 to 50 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydrocarbon-based Liquids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.033 to 110 cc\/second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGases\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.6 to 20,000 cc\/second\u003c\/li\u003e\n\u003cli\u003estandard conditions: 70˚F (21˚C ) at 14.7 psi (1 atm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: left;\"\u003eRCMS (Remote Control \u0026amp; Monitoring Software) Functions and Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003edisplay panel lock-out\u003c\/li\u003e\n\u003cli\u003eset points configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003erelay actuation delay timer\u003c\/li\u003e\n\u003cli\u003eindependently configurable for both on and off \/ increasing or decreasing\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 5,000 seconds\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eadjustable from 0 to 100 seconds\u003c\/li\u003e\n\u003cli\u003erelay mode configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eenergized above or below set point\u003c\/li\u003e\n\u003cli\u003erelay temperature mode configuration\u003c\/li\u003e\n\u003cli\u003eheater power setting\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ezero and span settings\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eanalog (4-20 mA) output configuration\u003cstrong\u003e*\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eview and print graphing (trend) function\u003c\/li\u003e\n\u003cli\u003econfiguring settings; write to device, save to file, and print\u003c\/li\u003e\n\u003cli\u003efault event log\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003ealso configurable from display panel\u003c\/p\u003e\n\u003ch4\u003eWeights and Dimensions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/classic-810-threaded-flow-level-interface-switch-transmitter\/\"\u003e810 threaded\u003c\/a\u003e: 2\" 'U' length: 7 pounds (3.18 kg)\u003c\/li\u003e\n\u003cli\u003ecarton size: 15x5x6 inches (38x13x15 cm)\u003c\/li\u003e\n\u003cli\u003eother models\/sizes: \u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us for more information\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWarranty\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eone (1) year from shipment date from factory (see full Terms and Conditions for details)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDisplay Panel Indicators\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003erelay 1 and 2\u003c\/li\u003e\n\u003cli\u003eset point 1 and 2\u003c\/li\u003e\n\u003cli\u003efault alarm\u003c\/li\u003e\n\u003cli\u003erun mode\u003c\/li\u003e\n\u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e\n\u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration Mode Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable sensitivity\u003c\/li\u003e\n\u003cli\u003ezero and span adjustment\u003c\/li\u003e\n\u003cli\u003eModbus addressable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eprimary watchdog circuit monitors microprocessor parameter anomalies\u003c\/li\u003e\n\u003cli\u003esecondary watchdog circuit monitors microprocessor health\u003c\/li\u003e\n\u003cli\u003eheater monitored for out-of-range conditions\u003c\/li\u003e\n\u003cli\u003efault mode de-energizes relay(s) and halts power to the heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApprovals and Certifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.csagroup.org\/\" target=\"_blank\"\u003eCSA Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eANSI\/UL Class I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eEx d IIB + H2\u003c\/li\u003e\n\u003cli\u003eAEx d IIB+H2 (Class I, Zone 1, Group IIB + H2,) T3\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSingle Seal Approval\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePer \u003ca rel=\"nofollow noopener\" href=\"https:\/\/webstore.ansi.org\/\" target=\"_blank\"\u003eANSI\u003c\/a\u003e\/ISA 12.27.01-2003\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\"\u003eFM Approvals\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div. 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 1, AEx d IIB+H2 T2D (Ta=75˚C) \/ T3 (Ta=65˚C)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type 4 \/ \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCRN Canadian Registration Number\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCRN approvals available\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"mailto:sales@psctexas.com\"\u003econtact us\u003c\/a\u003e for CRN information per model and jurisdiction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003ch2 style=\"text-align: left;\"\u003eApplications for the Kayden CLASSIC 800 Series\u003c\/h2\u003e\n\u003ch4\u003eFlow\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eflow switch for pump protection - dry alarm\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etank overflow protection\u003c\/li\u003e\n\u003cli\u003eflare gas monitoring\u003c\/li\u003e\n\u003cli\u003emonitoring purge air flow\u003c\/li\u003e\n\u003cli\u003elube oil systems\u003c\/li\u003e\n\u003cli\u003event monitoring\u003c\/li\u003e\n\u003cli\u003enatural gas to boilers\u003c\/li\u003e\n\u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e\n\u003cli\u003edrain line flow\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etanker loading and unloading\u003c\/li\u003e\n\u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e\n\u003cli\u003eremote indication of flow via analog and digital output communications\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLevel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003estorage tanks\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e\n\u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e\n\u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e\n\u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e\n\u003cli\u003etank overflow\u003c\/li\u003e\n\u003cli\u003esampler systems\u003c\/li\u003e\n\u003cli\u003esand separators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInterface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003econtrol in separation vessels\u003c\/li\u003e\n\u003cli\u003edetection\u003c\/li\u003e\n\u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMedia\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eliquids, air, and gases\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e\n\u003cli\u003eslurries\u003c\/li\u003e\n\u003cli\u003ecorrosive liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eProcess Conditions for this Switch \/ Transmitter for Flow, Level, Interface, and Temperature\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eFlow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003cli\u003eclean and dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003einsufficient straight run\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003eaerated fluids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eLevel\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003cli\u003enon-turbulent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition\u003c\/li\u003e\n\u003cli\u003eturbulence\u003c\/li\u003e\n\u003cli\u003elarge temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\"\u003eInterface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli\u003enon-turbulent applications\u003c\/li\u003e\n\u003cli\u003edry gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e\n\u003cli\u003ehigh aeration\u003c\/li\u003e\n\u003cli\u003ehigh turbulence\u003c\/li\u003e\n\u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878381183107,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-800-Series-Flow-Meter-Level-Switch-Interface-Switches-Temperature-Transmitter-Process-Solutions-Texas.png?v=1763385608"},{"product_id":"pilotrek-integrated-microwave-level-transmitter","title":"PiloTREK Integrated, Microwave Level Transmitter","description":"\u003cul\u003e \u003cli\u003e2-wire integrated transmitter for non-contact level metering\u003c\/li\u003e \u003cli\u003e25 GHz (K-band) measuring signal\u003c\/li\u003e \u003cli\u003eAccuracy up to Â±0.12 inch, 99-point linearization\u003c\/li\u003e \u003cli\u003eMeasuring range up to 75 feet\u003c\/li\u003e \u003cli\u003ePlastic housing\u003c\/li\u003e \u003cli\u003eHorn, planar, or parabolic antenna\u003c\/li\u003e \u003cli\u003eStainless steel or plastic encapsulated sensor\u003c\/li\u003e \u003cli\u003eExplosion-proof and IP68 variants available\u003c\/li\u003e \u003cli\u003e5 year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003eLevel measurement of liquids, emulsions, slurries, and other chemicals\u003c\/li\u003e \u003cli\u003eLevel measurement through plastic tank wall\u003c\/li\u003e \u003cli\u003eAgriculture\u003c\/li\u003e \u003cli\u003eConstruction materials\u003c\/li\u003e \u003cli\u003eChemical industry, for mid to large size vessels or chemical tanks\u003c\/li\u003e \u003cli\u003ePharmaceutical and chemical industry\u003c\/li\u003e \u003cli\u003eFood and beverage\u003c\/li\u003e \u003cli\u003ePower plants\u003c\/li\u003e \u003cli\u003eOil and petrochemical industry\u003c\/li\u003e \u003cli\u003eWater and wastewater industry\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eLinearly Polarized Microwave Impulses\u003c\/h4\u003e The PiloTREK Integrated Series pulse burst radar level transmitters emit linearly polarized microwave impulses. The polarization plane of the emitted impulses can be rotated fully in some PiloTREK models. The rotation of the polarization plane can minimize unwanted false reflections from disturbing objects or from the tank wall. The orientation of the polarization plane coincides with the line drawn between the cable glands. \u003ch4\u003ePulse Radar Level Transmitter Operations\u003c\/h4\u003e The operation of the non-contact microwave level transmitters is based on the measurement of the time of flight of the microwave burst. The propagation speed of microwave impulses is practically the same in air, gases and in vacuum, independently from the process temperature and pressure, so the measured distance is not affected by the physical parameters of medium to be measured. The level transmitter induces microwave impulses a few nanosecond long in the antenna and a part of the energy of the emitted signals is bounced (reflected) back from the measurement surface depending on the measured media. The time of flight of the reflected signal is measured and processed by the electronics, and then this is converted to distance, level or volume proportional data. The measurability of the level of a specific medium is depending on the signal strength of the reflected microwave impulses. The signal strength of the reflected impulses is considerably depending on the distance to be measured, the relative dielectric constant of the measured medium and the turbulence of the surface. The relative dielectric constant (Îµr) of the medium should be more than 1.4 in case of parabolic design, or it should be more than 1.9 with horn antenna types. \u003ch4\u003eProgramming with Echo Map\u003c\/h4\u003e With the help of the SAP-300 plug-in display, a simplified full-parameter programming can be accomplished. The parameters of measurement and output can be set using the text-based menu system.Â The large LCD dot-matrix display displays the measured values in numerical and bar graph form. The Echo Map feature helps to detect false reflections and aids the optimization of the measurement configuration. The background mapping feature provides excellent solution to ignore unwanted false reflections coming from (not-moving) disturbing objects. For this purpose the instrument needs to map the totally empty tank to create a âbackground imageâ. Then the measurement evaluation software of PiloTREK Integrated Series will automatically recognize and ignore the false reflections coming from the disturbing objects inside the tank. \u003ch4\u003ePiloTREK Integrated Series Microwave \/ Radar Level Transmitter\u003c\/h4\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eSupply voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e20â¦36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ4â¦+140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ22â¦+356Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess pressure\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eâ14.5â¦362.6 psig\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e4â¦20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003e1Â½\", 2\" or flanges or sanitary\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eIP67\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\" style=\"text-align: center;\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\" style=\"text-align: center;\"\u003eATEX, IEC Ex, INMETRO\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4 title=\"Page 5\"\u003ePiloTREK Microwave Level Transmitter Model Line-Up\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003ePiloTREK Series\u003c\/th\u003e \u003cth style=\"text-align: center;\" colspan=\"3\"\u003eMicrowave Level Transmitter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePiloTREK Integrated\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasured values\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLevel, Distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCalculated values\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eVolume, Mass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eFrequency of the measurement signal\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e~25 GHz (K-band)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring range\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.6 â 75 ft \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eLinearity error\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e\u0026lt;1.65 ft: Â±1 in; 1.65 â 3.3 ft: Â±0.6 in; 3.3 â 5 ft: Â±0.4 in; 5 â 26.25 ft: Â±0.12 in; \u0026gt;26.25 ft: Â±0.04% of the measured distance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal beam angle\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e11Â° \u003cem\u003e(depending on the antenna type)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMinimal Îµr of the medium\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e1.9 \u003cem\u003e(depending on the measuring range)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eResolution\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e1 mm (0.04 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eTemperature error (as per EN 61298-3)\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e0.05% FSK \/ 50 Â°F (-4Â°F...140Â°F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e20 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eDigital communication\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e4 â 20 mA + HART\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMeasuring frequency\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e10 â 60 sec as per the application settings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna diameter\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e38 mm (11â2\"), 48 mm (2\"), 75 mm (3\"), 148 mm (6\")\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAntenna material\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eHorn, Parabolic: 1.4571 (316Ti) stainless steel; enclosure: PP, PTFE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-22Â°F...212Â°F, (up to 248 Â°F for maximum 2 minutes) with PP antenna enclosure: maximum: 176Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMaximal process pressure\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e25 bar (363 psig) at 248Â°F; with plastic antenna enclosure: 3 bar (44 psig) at 77 Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eProcess connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eThreaded, Flanged or Sanitary connections\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIngress protection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIP68\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLiYCY type. 2x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.25 inch cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eElectrical protection\u003c\/th\u003e \u003ctd class=\"\" style=\"text-align: center;\"\u003eClass III\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eHousing material\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003ePlastic (PP)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eSealing\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eViton, EPDM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCommunication certifications\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eR\u0026amp;TTE, FCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eMass\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e2.2 â 3.5 lb\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cem\u003e*Under reference conditions of reflection and stabilized temperature\u003c\/em\u003e \u003ch4\u003eEx Certified PiloTREK Integrated Series Microwave Level Transmitters\u003c\/h4\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003e\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003ePlastic housing\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" rowspan=\"2\"\u003eEx marking\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eIEC Ex\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia IIB T6 ... T5 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eATEX\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx II 1G Ex ia IIB T6 ... T5 Ga\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eIntrinsically safe data\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eLi: 200 Î¼H, Ci: 30 nF, Ui: 30 V, Ii: 140 mA, Pi: 1 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003ePower supply\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eEx ia: 20 V â 30 V DC, Ex d[ia]: 24 V â 36 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eAmbient temperature\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003e-4Â°F...140Â°F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eElectrical connection\u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eIn case of WPM type: LiYCY type. 2x 0.5 mm\u003csup\u003e2\u003c\/sup\u003e (AWG20) shielded 0.25 inch cable; standard cable length: 16.5 ft \u003cem\u003e(can be ordered up to 100 ft)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878381215875,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PiloTREK-integrated-_WPM-183-4-nivelco-microwave-pulse-radar-level-transmitters-measuring-sensors-slurry-emulsion-liquids.jpg?v=1763385610"},{"product_id":"river-level-monitoring-system","title":"River Level Monitoring System","description":"This River Level Monitoring System provides insight to flood stages over time. This can help warn communities before flood waters cause damage to the surrounding areas. Its data logging capabilities allow river authorities and other monitoring bodies to see trends over time. Also, it can record months-worth of data without needing manual checks from operators. This package provides insight to monitoring authorities who need to assess risks from rapid \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003ewater level\u003c\/a\u003e changes during a rain event. Furthermore, it supports decisions to close bridges during heavy rains. It also provides capabilities to remotely monitor flood and drought conditions and datalog water level in general. \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eremote, \u003ca href=\"https:\/\/psctexas.com\/product\/pilotrek-w-200-non-contact-radar-level-transmitter\/\"\u003enon-contact level monitoring\u003c\/a\u003e\n\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/www.bluetooth.com\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBluetooth\u003c\/a\u003e connectivity in addition to smartphone access\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eintegrated \u003ca href=\"https:\/\/psctexas.com\/brand\/dehn\/\"\u003esurge protection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esecure operation, data logging, and trend monitoring with no monthly fees\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003euser-friendly, easy programming\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/psctexas.com\/brand\/iiot-technology-innovations\/\"\u003eoptional wireless transmitters (up to 7 miles)\u003c\/a\u003e\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003eoptional upgraded online dashboard with numerous integrated data points and advanced functions\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/echo-map-river-level-monitoring-system.jpg\"\u003e\u003cimg class=\"alignright wp-image-20995\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/echo-map-river-level-monitoring-system-300x164.jpg\" alt=\"echo-map-river-level-monitoring-system\" width=\"500\" height=\"274\"\u003e\u003c\/a\u003eRiver Level Monitoring Package\u003c\/h3\u003e A typical River Level Monitoring System includes a \u003ca href=\"https:\/\/psctexas.com\/product\/pilotrek-w-200-non-contact-radar-level-transmitter\/\"\u003enon-contact level sensor\u003c\/a\u003e, power supply, as well as built-in \u003ca href=\"https:\/\/psctexas.com\/brand\/dehn\/\"\u003esurge protection\u003c\/a\u003e. They offer easy programming, data logging, in addition to remote monitoring capabilities. Moreover, it's packaged in an IP rated, water resistant case and offers security features to prevent tampering. Our continuous River Level Monitors are ideal for river authorities as an easy-to-install solution that can constantly monitor and log river level values. Operators can program these systems directly via the included \u003ca href=\"https:\/\/psctexas.com\/product\/pr-4116-universal-temperature-transmitter\/\"\u003euniversal transmitter\u003c\/a\u003e or by connecting a smart device via Bluetooth. \u003ch3 style=\"text-align: left;\"\u003eOptional Wireless Transmitters\u003c\/h3\u003e As an option, these River Level Monitor packages can be equipped with wireless transmitters to transmit data up to 7 miles. This technology is ideal for rural areas and small towns to provide a low-cost, low-maintenance, and highly reliable remote monitoring of river levels without monthly fees or cellular charges. They can also connect to cellular networks and transmit data even further, thus integrating seamlessly with a remote control room or other type of computing server. As an option, online software is available to integrate all data points, generate predictive trends, and provide easy access to historical data.","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878390423683,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/continuous-river-level-monitoring-system-process-solutions-corp-texas.png?v=1763385902"},{"product_id":"optiflux-4400-magmeter","title":"OPTIFLUX 4400 Magmeter","description":"The OPTIFLUX 4400 \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/magmeters\/\"\u003eelectromagnetic flow meter (EMF)\u003c\/a\u003e, or magmeter, arrives in accordance with IEC 61508 for safety-related \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater and wastewater applications\u003c\/a\u003e, up to \u003ca href=\"https:\/\/www.iec.ch\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003esafety integrity level (SIL) 2\/3\u003c\/a\u003e. It features automated partial proof testing capabilities, which allows extension in the time interval between full proof tests while increasing plant uptime in safety instrumented systems (SIS). Aside from safety applications, the OPTIFLUX 4400, from \u003ca href=\"https:\/\/psctexas.com\/brand\/krohne\/\"\u003eKROHNE\u003c\/a\u003e, is particularly suitable for process applications with high accuracy requirements and difficult \u003ca href=\"https:\/\/psctexas.com\/product-category\/water-treatment\/flow-wastewater\/\"\u003eflow\u003c\/a\u003e conditions, for example, pulsating and turbulent flow. Due to its wide selection of lining and electrode materials, it's ideal for flow measurement and dosing of chemicals and corrosive liquids such as acids. This magmeter can improve conductivity measurement, and operators can also monitor a defined range of conductivity. The OPTIFLUX 4400 magmeter comes with a wide range of flow and process diagnostics for a high degree of reliability. In addition, it features a best-in-class diagnostic test interval including a fault response time of only two minutes. If running out of spec, this flow meter will issue an alarm to the control room much faster than other EMFs on the market. The OPTICHECK service tool can also provide a full on-site verification of the OPTIFLUX 4400 without process interruption. \u003cimg class=\"alignright wp-image-25341 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/09\/optiflux-4400-krohne-electromagnetic-flowmeter-emf-magmeter-wastewater-flow-psc-texas.png\" alt=\"optiflux-4400-krohne-electromagnetic-flowmeter-emf-magmeter-wastewater-flow-psc-texas\" width=\"1666\" height=\"1066\"\u003e \u003ch3\u003eFeatures of the OPTIFLUX 4400 Magmeter*\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eautomated partial proof testing capability for extending full proof test intervals\u003c\/li\u003e \u003cli\u003eintegrated conductivity measurement\u003c\/li\u003e \u003cli\u003eenhanced diagnostic package: \u003cul\u003e \u003cli\u003ecompliant with \u003ca href=\"https:\/\/www.namur.net\/en\/publications\/news-archive\/ne-107-has-been-revised.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNAMUR NE 107\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ediagnostic test interval including fault response time of only 2 minutes, it also alerts if meter runs out of spec\u003c\/li\u003e \u003cli\u003edetects gas bubbles, solids, electrode corrosion, deposits on the electrodes, conductivity changes, an empty or partially filled pipe, a flow profile disturbance, external magnetic fields, etc.\u003c\/li\u003e \u003cli\u003eredundant data storage\u003c\/li\u003e \u003cli\u003ereal-time clock for logging events\u003c\/li\u003e \u003cli\u003euser-friendly color display for status indication\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eease of installation and device set-up: \u003cul\u003e \u003cli\u003eoptimized device menu with reduced menu items for quick commissioning\u003c\/li\u003e \u003cli\u003eavailable with \"virtual reference\" option: cost-saving installation without grounding rings (in non-SIL applications)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ehigh measuring accuracy and long-term stability, for example, measuring error of only Â±0.2% of measured value Â±1 mm\/s\u003c\/li\u003e \u003cli\u003ewide range of liner and electrode materials\u003c\/li\u003e \u003cli\u003eapproval for use in \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous areas\u003c\/a\u003e: ATEX, IECEx db eb\u003c\/li\u003e \u003cli\u003efield device verification of flowmeter with the OPTICHECK Master and OPTICHECK DTM service tools, e.g. for partial proof test documentation according to \u003ca href=\"https:\/\/www.iec.ch\/functional-safety\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIEC 61508\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e *Product features and options depend on device configuration. Contact us to make sure that your functionality requirements are available in a single device. \u003ch3\u003eCommon Magmeter Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eSafety Instrumented Systems (SIL 2\/3)\u003c\/li\u003e \u003cli\u003eapplications with high accuracy requirements\u003c\/li\u003e \u003c\/ul\u003e","brand":"KROHNE","offers":[{"title":"3\" DN080","offer_id":45878390456451,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"4\" DN100","offer_id":45878390489219,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"6\" DN150","offer_id":45878390521987,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"8\" DN200","offer_id":45878390554755,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"10\" DN250","offer_id":45878390587523,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/OPTIFLUX-4400-krohne-electromagnetic-flow-meter.png?v=1763385903"},{"product_id":"liquid-dosing-system","title":"Liquid Dosing System","description":"\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eOur liquid dosing system eliminates the guess work in the dosing of liquids such as dyes and chemicals to fuels, water, and in manufacturing applications. Our dosing systems can be designed to accommodate any flow rate requirements and also offer a wide range of liquid handling capability including corrosive liquids. The color \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003etouchscreen controller\u003c\/a\u003e provides an intuitive, user-friendly interface with built-in security and safety features such as password protection, alarming, and quick shutdown. This dosing systems also includes manual mode for testing, troubleshooting, and calibration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003efully loaded, user-friendly touchscreen interface with custom functions available\u003c\/li\u003e\n\u003cli\u003ebudget-friendly, flexible designs that can accommodate a variety of liquid types, flow rates, and installation requirements\u003c\/li\u003e\n\u003cli\u003estand-alone, rack-mount, table-top, in-line \/ on-site, and portable dosing system options\u003c\/li\u003e\n\u003cli\u003efully automatic operation with alarming and quick shutdown\u003c\/li\u003e\n\u003cli\u003eautomatic Totalizing Mode for pumping a specific volume in addition to batch dosing\u003c\/li\u003e\n\u003cli\u003eautomatic Run Mode for pumping a volumetric ratio in real time\u003c\/li\u003e\n\u003cli\u003emanual mode operation for testing, troubleshooting, as well as calibration\u003c\/li\u003e\n\u003cli\u003euniversal supply by AC or DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFully Automated Liquid Dosing System\u003c\/h2\u003e\n\u003cp\u003eWith in-house assembly in Houston, Texas, our engineers will work closely with your team to design and build the ultimate liquid dosing system for your application. Our systems are available in standalone, rack-mount, portable, table-top, as well as in-line or on-site stationary designs. As a result, our liquid dosing systems can fit most any dosing application and environment. We can also write custom functions or operations into the programming to fit your exact application requirements and make your process seamless and hands-off. The flexibility of our dosing systems also allows a wide range of flow rates, viscosities, corrosive liquids, and more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehigh accuracy (from ppm to high-flow injection)\u003c\/li\u003e\n\u003cli\u003erepeatable batch consistency\u003c\/li\u003e\n\u003cli\u003eintegration with PLC\/SCADA systems\u003c\/li\u003e\n\u003cli\u003eimproves safety and reduces operator error (reduces material handling)\u003c\/li\u003e\n\u003cli\u003ereduces chemical waste and operational costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOffering a Variety of Styles and Sizes\u003c\/h2\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg height=\"500\" width=\"500\" style=\"margin-left: 25px; float: right;\" alt=\"Liquid-Dosing-Pump-for-Manufacturing-Process-Analyzer-Rooms-Diesel-Fuel-Blending-Bronkhorst-Flow-Instrumentation-Process-Solutions-Corp-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Liquid-Dosing-Pump-for-Manufacturing-Process-Analyzer-Rooms-Diesel-Fuel-Blending-Bronkhorst-Flow-Instrumentation-Process-Solutions-Corp-Texas.png?v=1771521538\"\u003e\u003c\/div\u003e\n\u003cp\u003eStand-alone units can include a sunshield and sun-readable display, thus making it suitable for use outdoors. This is also useful in harsh environments where the touchscreen HMI needs protection when not in use, such as on marine vessels. Table-top versions are ideal for laboratories and \u003ca title=\"Analyzer Solutions\" href=\"https:\/\/www.psctexas.shop\/collections\/analyzer-solutions\"\u003eanalyzer\u003c\/a\u003e rooms and can easily be transported or stored when not in use. Our in-line and on-site units are ideal for manufacturing applications, gas sampling system automation, gas processing, and other continuous or batch dosing processes. Portable units can be built in custom \u003ca title=\"Pelican Cases\" rel=\"nofollow noopener\" href=\"https:\/\/www.pelican.com\/us\/en\/\" target=\"_blank\"\u003ePelican\u003c\/a\u003e cases; thus allowing easy transportation while offering sufficient protection from the environment or other damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCommon Applications for Liquid Dosing Systems\u003c\/h2\u003e\n\u003cp\u003eThis automated dosing system is ideal for batching or continuous dosing of additives to fuels such as diesel blending, automating sampling systems in analyzer rooms, or for manufacturing processes. Liquid dosing systems are useful in gas processing facilities, refineries, pilot plants, analyzer rooms, drill sites, in food and beverage production facilities, as well as offshore on rigs or ships. Common industrial uses include water in diesel applications, dosing of chemicals to fuels, and dosing chemicals such as chlorine to wastewater streams. Furthermore, out dosing systems are useful for applying coatings to machinery parts, adding dyes and flavors to food and beverages, and much more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and Energy\n\u003cul\u003e\n\u003cli\u003emarine fuel blending (viscosity modifiers, lubricity additives)\u003c\/li\u003e\n\u003cli\u003ediesel and gasoline additive injection\u003c\/li\u003e\n\u003cli\u003ecorrosion inhibitors for example in pipelines\u003c\/li\u003e\n\u003cli\u003ebiodiesel blending\u003c\/li\u003e\n\u003cli\u003emethanol injection (hydrate prevention)\u003c\/li\u003e\n\u003cli\u003edemulsifiers \/ emulsion breakers\u003c\/li\u003e\n\u003cli\u003escale inhibitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater Treatment\n\u003cul\u003e\n\u003cli\u003echlorine and disinfectant dosing\u003c\/li\u003e\n\u003cli\u003epH adjustment (acid\/caustic)\u003c\/li\u003e\n\u003cli\u003ecoagulants and flocculants\u003c\/li\u003e\n\u003cli\u003ecooling tower chemical treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eChemical Processing\n\u003cul\u003e\n\u003cli\u003ecatalyst injection\u003c\/li\u003e\n\u003cli\u003epolymer additives\u003c\/li\u003e\n\u003cli\u003ereaction control chemicals\u003c\/li\u003e\n\u003cli\u003ebatch blending operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and Beverage\n\u003cul\u003e\n\u003cli\u003eflavor and dye dosing\u003c\/li\u003e\n\u003cli\u003epreservatives and other additives\u003c\/li\u003e\n\u003cli\u003ecleaning-in-place (CIP) chemicals\u003c\/li\u003e\n\u003cli\u003ecarbonated beverage additives\u003c\/li\u003e\n\u003cli\u003ebioreactors and fermentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePharmaceuticals and Biotechnology\n\u003cul\u003e\n\u003cli\u003enutrient feeds in bioreactors\u003c\/li\u003e\n\u003cli\u003esterile reagent dosing\u003c\/li\u003e\n\u003cli\u003ebuffer and media preparation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurface Treatment and Industrial Cleaning\n\u003cul\u003e\n\u003cli\u003eacid baths\u003c\/li\u003e\n\u003cli\u003eelectroplating chemicals\u003c\/li\u003e\n\u003cli\u003edetergent dosing\u003c\/li\u003e\n\u003cli\u003erust inhibitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eLiquid Dosing System with Intuitive Controls and Seamless Process Control\u003c\/h2\u003e\n\u003cp\u003eFeaturing a touchscreen interface, our liquid dosing systems are reliable, effective, easy to control, and ready to use upon arrival. The user-friendly programming includes full functionality such as automatic operation and totalizing mode. Being built in-house in Houston, Texas, our dosing units can include additional physical or programmable features to meet the unique operation, safety, and environmental requirements of your application.\u003c\/p\u003e\n\u003cp\u003eFurthermore, automatic operation doesn't mean it's not monitored. Our liquid dosing systems include alarming to help prevent operational errors. It also features a quick shutdown function to ensure safety and to provide operators with ultimate control. Alarms can even be delivered via text, email, beacon lights on the unit, as well as audible alerts. Password protection is also included to ensure these dosing systems can't be easily tampered with or accidentally modified. In addition to automated functions, our dosing units feature a manual operation mode, which allows operators to test, troubleshoot, and calibrate the unit, thus providing ultimate control over the dosing system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eUniversal Liquid Dosing System with Fast Production\u003c\/h2\u003e\n\u003cdiv class=\"flex flex-col text-sm\"\u003e\n\u003carticle data-turn=\"assistant\" data-scroll-anchor=\"true\" data-testid=\"conversation-turn-14\" data-turn-id=\"request-WEB:0c3b5ea9-6422-4678-95c2-33108e8c0a56-6\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" dir=\"auto\" data-message-id=\"4d7cbfd9-e4f9-4a9e-8d0f-3cead97904d8\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling\"\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"688\" data-start=\"0\"\u003eOur automated liquid dosing systems are engineered for flexibility because no two applications are the same. Rather than forcing you into a one-size-fits-all solution, the standard design of our dosing systems allow easy customization to fit your exact process requirements. With a universal power supply that operates on AC or DC, these units are ready for deployment anywhere, whether onshore, offshore, in-field, or at sea. The modular design supports a wide range of pump technologies, thus allowing accurate dosing of virtually any liquid at nearly any flow rate or viscosity. From standard fluids to aggressive or corrosive chemicals, our systems deliver precision, reliability, and performance wherever you need it most.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eComplete Control over Liquid Dosing Processes\u003c\/h2\u003e\n\u003cp\u003eIn addition to being intuitive and user-friendly, the control interface on our liquid dosing systems are extremely versatile and far from basic. Aside from the modifiable, preprogrammed functions, the controller also offers powerful data logging with remote access and monitoring capabilities. It can even display multiple languages! \u003ca title=\"Send Us an Email\" href=\"mailto:sales@psctexas.com\"\u003eGet in touch\u003c\/a\u003e with us today to speak to our engineering and design team about your process needs and let us come up with a unique, effective, and affordable solution for you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eRelated Technologies\u003c\/h2\u003e\n\u003ch4\u003eFlow Controller and Readout for Existing Instrumentation\u003c\/h4\u003e\n\u003cp\u003eAlready own the pumps, flow meters, and flow controllers? Check out our plug-and-play flow controller: the \u003ca title=\"FlowLogic Readout and Flow Controller\" href=\"https:\/\/www.psctexas.shop\/products\/flowlogic-flow-control-system-readout\"\u003eFlowLogic\u003c\/a\u003e readout and flow control system. This flow controller and readout system eliminates the need for using a laptop, thus allowing easy operation, configuration, and control of any digital flow instrumentation \/ system. The FlowLogic can control up to four flow meters or controllers and includes advanced, built-in functions such as totalizer mode, continuous operation mode, measured value, set point, and much more. This flow controller includes the indication and operation of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasured Value\u003c\/li\u003e\n\u003cli\u003eSetpoint\u003c\/li\u003e\n\u003cli\u003eInstrument Range\u003c\/li\u003e\n\u003cli\u003eTrending Values Totalizer (limit, value, totalizer mode, new setpoint)\u003c\/li\u003e\n\u003cli\u003eas well as custom programmable functions to meet your requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVapor Generation System\u003c\/h4\u003e\n\u003cp\u003eIf generating a vapor stream is what you really need, check out our \u003ca title=\"Vapor Generation Systems from Process Solutions Corp.\" href=\"https:\/\/www.psctexas.shop\/products\/psc-controlled-evaporation-system-vapor-generation\"\u003eVapor Generation Systems\u003c\/a\u003e. The precision control and \u003ca title=\"Low Flow Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/low-flow-meters-and-controllers\"\u003elow flow\u003c\/a\u003e capabilities of our controlled evaporation technology makes for an easy, all-in-one vapor generation system. It's an especially useful device for laboratories, research, as well as for intricate manufacturing processes. These systems include up to 3 \u003ca title=\"Gas Flow Meters\" href=\"https:\/\/www.psctexas.shop\/collections\/gas-flow-meters-and-controllers\"\u003egas flow meters\u003c\/a\u003e, \u003ca title=\"Liquid Flow Meters\" href=\"https:\/\/www.psctexas.shop\/collections\/liquid-flow-meters-and-controllers\"\u003eliquid flow meters\u003c\/a\u003e and controllers, and \u003ca title=\"CEM Series, Controlled Evaporation Mixers\" href=\"https:\/\/www.psctexas.shop\/products\/cem-evaporator-series-controlled-evaporator-mixer\"\u003evaporizers\u003c\/a\u003e and integrated mixing chamber. Our vapor generation systems are available in table-top versions or they can integrated in-line to a new or existing manufacturing, gas sampling, or similar processes where highly repeatable and accurate vapor generation is mandatory.\u003c\/p\u003e","brand":"Process Solutions Corp.","offers":[{"title":"Default Title","offer_id":45878391701635,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Liquid-Dosing-System-Fuel-Blending-Automated-Totalizing-Dosing-Systems-Manufacturing-Diesel-Dosing-Process-Solutions-Corp-PSC-Texas.png?v=1771521348"},{"product_id":"liquid-dosing-pumps","title":"Liquid Dosing Pumps","description":"We offer a wide range of dosing pumps to suit a large variety of applications. From gallons per minute for handling large quantities of water, to grams per hour for analytical and research purposes, to specialized materials for handling corrosive substances, we can provide the instrumentation and engineering support required for optimal efficiency and performance. \u003cul\u003e \u003cli\u003elow flow dosing pumps\u003c\/li\u003e \u003cli\u003eWADose high pressure pumps\u003c\/li\u003e \u003cli\u003egear pumps\u003c\/li\u003e \u003cli\u003eother pumps available upon request\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eLow Flow Dosing Pumps\u003c\/h3\u003e Our low flow dosing pumps can handle fluids in the microliter to milliliter range for small volumetric flows. These ultra low flow pumps are often necessary for analytical processes, laboratory research, in the chemistry lab, in biotechnology processes such as bioreactors, pharmaceutical production and research, and even in mechanical engineering. To ensure process fidelity, our low flow dosing pumps offer high stability. For example, our micro-annular gear pumps use technology that opens doors to a wide range of applications. Our engineering team will be happy to assist you with design, pump selection, and even in-person training for your staff. We'll even help you select the right connectors, filters, adaptors, and other sensors necessary for your process. \u003ch5\u003eMicro Annular Gear Pumps\u003c\/h5\u003e \u003cul\u003e \u003cli\u003elow shear stress\u003c\/li\u003e \u003cli\u003elow pulsation\u003c\/li\u003e \u003cli\u003elight weight and compact design\u003c\/li\u003e \u003cli\u003elow dead volume\u003c\/li\u003e \u003cli\u003elong service life\u003c\/li\u003e \u003cli\u003eresistance to corrosion and wear\u003c\/li\u003e \u003c\/ul\u003e Our micro annular gear pumps are ideal for dosing and metering small amounts liquids. These pumps can handle a wide range of viscosities, flow rates, pressures, corrosive liquids, and even hazardous area certifications. The capability for liquid viscosity ranges from 0.3 to 1 million mPas. Dosing volumes start at 0.25 Âµl with flows ranging from 1 Âµl\/h to 1.1 l\/min. Pressure ranges from 0 to 150 bar (or higher) are possible. In addition, we even offer explosion-proof and magnetic hermetic options. \u003ch3\u003eWADose High Pressure Pumps\u003c\/h3\u003e \u003ca href=\"https:\/\/www.bronkhorst.com\/getmedia\/fcd8529b-5fb9-4fd3-acf5-cb12f9b83d2b\/Micro-dosing-pump-Wadose.png?width=\"\u003e\u003cimg class=\"size-medium alignright\" src=\"https:\/\/www.bronkhorst.com\/getmedia\/fcd8529b-5fb9-4fd3-acf5-cb12f9b83d2b\/Micro-dosing-pump-Wadose.png?width=\" alt=\"Bronkhorst-WADose-Pump-Liquid-Dosing-Low-Flow-Manufacturing-Instrumentation-PSC-Texas\" width=\"362\" height=\"374\"\u003e\u003c\/a\u003e WADose high pressure pumps are often combined with a \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis mass flow meter\u003c\/a\u003e for dosing purposes, such as dosing catalysts or liquefied gas dosing. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/precise-liquefied-gas-dosing\/\"\u003eLiquefied gas dosing\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/precise-liquefied-gas-dosing\/\"\u003eDosing of pharmaceutical agents in liquid state\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGear Pumps for Liquid Dosing\u003c\/h3\u003e Gear pumps can be used in combination with our \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/coriolis-flow\/\"\u003eCoriolis flow meters\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product\/es-flow-low-flow-ultrasonic-flow-meters-controllers\/\"\u003eUltrasonic volumetric flow meters\u003c\/a\u003e for various \u003ca href=\"https:\/\/psctexas.com\/tag\/dosing-pump\/\"\u003edosing applications\u003c\/a\u003e. \u003ch3\u003e\u003c\/h3\u003e Pumps are core components in a liquid dosing system. Dosing or metering pumps are able to measure the volume flow of a liquid. Process conditions like temperature, air containment, back pressure, and wear and tear influence the measured value. Therefore, the pump needs an additional device to make the required correction. \u003ca href=\"https:\/\/psctexas.com\/product-brands\/bronkhorst\/\"\u003eBronkhorst mass flow meters and volume flow meters\u003c\/a\u003eÂ offer the opportunity for direct steering of pumps to minimize the influence of the process conditions on accuracy and repeatability. And placing a flow meter inline with a pump gives the opportunity of pump steering by correcting the pump rotation frequency. Technically, this can be done by a flow meter and a PID controller. https:\/\/www.youtube.com\/watch?v=dDcBP5KXdSU \u003ch3\u003eFlow Meter with Integrated PID Controller\u003c\/h3\u003e We deliverÂ \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/liquid-flow\/\"\u003eflow meters\u003c\/a\u003e with an integrated PID controller, thus avoiding the use of the filtered flow meter analog outputs and a separate PID controller. So, this \u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003ecombination of a pump and smart mass flow meter\u003c\/a\u003e offers direct mass flow control with high accuracy and repeatability, and is independent of process conditions. Additionally, this solution uses an unfiltered control signal, which also offers very high control speed and stability. \u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow meters\u003c\/a\u003e can be combined with different kind of pumps as long as these can be controlled by a 0(4)-20 mA or 0-5(10) Vdc control signal. Also, we offer functional and system tests for a flow meter \/ pump system including fine-tuning. \u003ch3\u003eImproving Dosing Pump Processes with Flow Meters\u003c\/h3\u003e https:\/\/vimeo.com\/652784965 \u003ch3\u003eLiquid Dosing Applications with Pump and Flow Meter\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/dosing-pump-control-for-improved-batching\/\"\u003eDosing Pump Control for Improved Batching\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/liquid-flow-meters-for-mrna-vaccine-production\"\u003emRNA Vaccine Production\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/how-can-you-improve-your-dosing-pump-performance-with-flow-meters\/\"\u003eDosing Pump in Laboratories and Pilot Plants\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/metering-pump-performance-improved-with-flow-meters\/\"\u003eImproving Metering Pump Performance\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-solution-for-hydrogen-storage\/\"\u003eHydrogen Storage on a Liquid Organic Hydrogen Carrier (LOHC)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/flow-meter-dosing-pump-combinations\/\"\u003eCommon Flow Meter and Dosing Pump Combinations\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/best-dye-dosing-systems\/\"\u003eHigh Precision Dye Dosing System\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=gkEEXey3RfQ","brand":"Bronkhorst","offers":[{"title":"Default Title","offer_id":45878391734403,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/low-flow-liquid-dosing-pump-hnpm-tuthill-rotary-pumps-gear-pump-process-solutions-corp-texas.png?v=1763385925"},{"product_id":"white-led-linears-industrial-lighting","title":"White LED Linears, Industrial Lighting","description":"\u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e We offer a variety of White LED Linears luminaire options from \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003eHorner Lighting Group\u003c\/a\u003e. Along with a multitude of add-on accessories for any situation, our line of White LED Linear products are a perfect fit for indoor high, low, and aisle bay applications. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cul\u003e \u003cli\u003einstant strike\u003c\/li\u003e \u003cli\u003eeasy mounting via cable \u003cem\u003e(standard)\u003c\/em\u003e\n\u003c\/li\u003e \u003cli\u003eoutput of 9,845 - 77,192 lumens\u003c\/li\u003e \u003cli\u003edimmable options enable the use of occupancy sensors for power savings\u003c\/li\u003e \u003cli\u003euniversal AC input \/ full range, 120~277 VAC \u003cul\u003e \u003cli\u003e347\/480 VAC option available\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003edesigned and assembled in USA with global components\u003c\/li\u003e \u003cli\u003eon \/ off motion sensor option\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePowerful LED Linears for Industrial Use\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cul\u003e \u003cli\u003e80 CRI standard enhances color and clarity\u003c\/li\u003e \u003cli\u003epowerful light engine creates even output with 5 different distributions\u003c\/li\u003e \u003cli\u003eoptional field-installable aluminum reflectors for low or high bay, aisle, and task applications\u003c\/li\u003e \u003cli\u003eoptional acrylic diffuser provides control, minimizing potential for glare\u003c\/li\u003e \u003cli\u003etypical mounting heights of 8â - 60â\u003c\/li\u003e \u003c\/ul\u003e https:\/\/youtu.be\/KkPNAC9JdA4 \u003ch3\u003eHigh Quality and Reliable Performance\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cul\u003e \u003cli\u003e5 year warranty backed by U.S. company founded in 1949\u003c\/li\u003e \u003cli\u003erated for 62,000 hrs at L90\u003c\/li\u003e \u003cli\u003eup to 169 lumens\/watt\u003c\/li\u003e \u003cli\u003equality driver with integrated 4 kV surge\u003c\/li\u003e \u003cli\u003e-40 to 122ËF ambient temperatureÂ ensures long lifetime in a varietyÂ of conditions\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCost Effective Industrial Lighting\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cul\u003e \u003cli\u003etypical payback of 12 â 24 months\u003c\/li\u003e \u003cli\u003eoptional 0-10 dimming\u003c\/li\u003e \u003cli\u003eutilize optional motion and\/or daylight sensors for additional energy savings\u003c\/li\u003e \u003cli\u003eengineered with quality aluminum and space-age materials \u003cul\u003e \u003cli\u003eminimalist design improves cooling and reduces shipping costs\u003c\/li\u003e \u003cli\u003esuperior LED thermal management ensures long lifetime\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ereduce downtime and minimize maintenance costs\u003c\/li\u003e \u003cli\u003epotential for rebate savings through \u003ca href=\"http:\/\/www.designlights.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eDLC certifications (refer to DLC QPL at www.designlights.org)\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eWhite LED Linears Model Lineup\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\" colspan=\"10\"\u003e\u003cstrong\u003e4 Foot Linears\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e (L x W x H)\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e\u003cstrong\u003eCRI\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e\u003cstrong\u003eCCT\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e\u003cstrong\u003eLumens\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e\u003cstrong\u003eTotal Watts\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e\u003cstrong\u003eLumens per Watt\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u003cstrong\u003eL70\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u003cstrong\u003eL90\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-3 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-WLL-1080\u003c\/strong\u003e (1 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e3.53 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e49\" x 3.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e11,360\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e80\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-4 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-WLL-2160\u003c\/strong\u003e (2 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e7.3 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e49\" x 6.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e22,720\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e160\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-WLL-3240\u003c\/strong\u003e (3 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e10.9 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e49\" x 10.6\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e34,080\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e240\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-WLL-4320\u003c\/strong\u003e (4 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e14.6 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e49\" x 15.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e45,440\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e320\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-7 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-WLL-6480\u003c\/strong\u003e (6 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e21.8 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e49\" x 24.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e68,160\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e480\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\" colspan=\"10\"\u003e\u003cstrong\u003e8 Foot Linears\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e (L x W x H)\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e\u003cstrong\u003eCRI\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e\u003cstrong\u003eCCT\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e\u003cstrong\u003eLumens\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e\u003cstrong\u003eTotal Watts\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e\u003cstrong\u003eLumens per Watt\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u003cstrong\u003eL70\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u003cstrong\u003eL90\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-9 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-W8LL-1080\u003c\/strong\u003e (1 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e7.5 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e96\" x 3.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e12,080\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e80\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e151\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-10 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-W8LL-1160\u003c\/strong\u003e (1 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e7.5 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e96\" x 3.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e22,720\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e160\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-11 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eETG-W8LL-2320\u003c\/strong\u003e (2 module)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e14.8 lbs\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e96\" x 6.1\" x 3\"\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e80+\u003c\/td\u003e \u003ctd class=\"column-5\" style=\"text-align: center;\"\u003e5000K\u003c\/td\u003e \u003ctd class=\"column-6\" style=\"text-align: center;\"\u003e45,440\u003c\/td\u003e \u003ctd class=\"column-7\" style=\"text-align: center;\"\u003e320\u003c\/td\u003e \u003ctd class=\"column-8\" style=\"text-align: center;\"\u003e142\u003c\/td\u003e \u003ctd class=\"column-9\" style=\"text-align: center;\"\u003e\u0026gt;220,000 hrs\u003c\/td\u003e \u003ctd class=\"column-10\" style=\"text-align: center;\"\u003e\u0026gt;60,000 hrs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003ePower Options\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr class=\"row-3\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ePart Number Adder\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eBuilt in with the Light\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e\u003cstrong\u003e4 Foot\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e\u003cstrong\u003e8 Foot\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-4\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eP1\u003c\/strong\u003e \u003cem\u003e(standard)\u003c\/em\u003e\n\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eOn\/Off 120~277 VAC\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eP2\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e480 VAC\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eP4\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eDimming 120~277 VAC\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eColor and CRI Options\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr class=\"row-8\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ePart Number Adder\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003e\u003cstrong\u003e4 Foot\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003e\u003cstrong\u003e8 Foot\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-9\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003eC1 \u003c\/strong\u003e\u003cem\u003e(standard)\u003c\/em\u003e\n\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e5000K 80 CRI\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-10\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eC2\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4000K 80 CRI\u003c\/td\u003e \u003ctd class=\"column-3\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003ctd class=\"column-4\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eAdditional Accessories\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr class=\"row-2 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ePart Number Adder\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-3 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eB14\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eRaised Unistrut Mount\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-4 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eD4\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eRotary Dimmer\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eG1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e6 ft cord 120VAC NEMA 5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eG2\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e6 ft cord 277VAC NEMA 7\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-7 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eM1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eOn\/Off Motion\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-8 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eM2\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eOn\/Off Motion Cold\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-9 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eM6\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eMotion Sensor with Step Dimming\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-10 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eR1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eRemote Mount Driver with 10 foot cable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-11 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-011\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eWired for battery back up\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-12 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\n\u003cstrong\u003e-044\u003c\/strong\u003e (available for 1 thru 6 tube)\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eEnd Gaskets for Dust and Debris\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-23 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-BKT-B27\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eOne set of 2 linear clip-on mounting brackets for units with power supplies with Unistrut \/ surface mountingÂ \u003cem\u003e(will mount 1 linear light)\u003c\/em\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-24 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-DIM-100K-06\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e100K potentiometer dimming assembly with a 6' dimming wire lead\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-25 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-DIM-100K-12\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e100K potentiometer dimming assembly with a 12' dimming wire lead\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-26 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-DIM-SLD-06\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eslide dimmer in 2x4 box with 2 top and 2 bottom 1\/2\" conduit 6' cables\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-27 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-DIM-SLD-12\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eslide dimmer in 2x4 box with 2 top and 2 bottom 1\/2\" conduit 12' cables\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eRecommended Reflectors\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr class=\"row-15 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr class=\"row-16 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-WLBRO\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1 low bay 4 ft white reflector with 2 clips, highly reflective with 98% diffused reflector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-17 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-LBR1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1 low bay 4 ft specular reflector with 2 clips, 52Â° angle light distribution\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-18 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-HBR1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1 high bay 4 ft specular reflector with 2 clips, 44Â° angle light distribution\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-19 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003eETG-ABR1\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1 aisle bay 4 ft specular reflector with 2 clips, 33Â° angle light distribution\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e [embed]https:\/\/www.youtube.com\/watch?v=-ub0JB1Cxec[\/embed] \u003ch3\u003eCommon Uses for White LED Linears\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eGrocery Stores\u003c\/li\u003e \u003cli\u003eWarehouses and Manufacturing Facilities\u003c\/li\u003e \u003cli\u003eDepartment Stores\u003c\/li\u003e \u003cli\u003eSport Stadiums, Music Venues, and Theaters\u003c\/li\u003e \u003cli\u003eNatatoriums and Sports Complexes\u003c\/li\u003e \u003cli\u003eIndustrial Garages\u003c\/li\u003e \u003cli\u003eHangars\u003c\/li\u003e \u003cli\u003eIndoor Storage Facilities\u003c\/li\u003e \u003cli\u003eGymnasiums\u003c\/li\u003e \u003c\/ul\u003e","brand":"Horner Automation","offers":[{"title":"Default Title","offer_id":45878391898243,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/white-led-linears-industrial-light-horner-lighting-group-made-in-usa-psc-texas-louisiana-oklahoma.jpg?v=1763385931"},{"product_id":"nivopress-n-hydrostatic-level-transmitter","title":"NIVOPRESS N, Hydrostatic Level Transmitter","description":"\u003cul\u003e \u003cli\u003emeasuring range up to 656 ft (200 m)\u003c\/li\u003e \u003cli\u003estailess steel or fully plastic body\u003c\/li\u003e \u003cli\u003eventing tube in cable\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 protection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eremote programmable\u003c\/li\u003e \u003cli\u003eÃ22 \/ 24 mm (Ã0.85 \/ 1 inch) tube\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e [embed]https:\/\/www.nivelco.com\/public\/files\/803db18b-ee74-4bf8-8051-1cc788a97cde\/07_NIVOPRESS%20N.mp4[\/embed] \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003eNIVOPRESS N Hydrostatic Level Transmitter\u003c\/h3\u003e The NIVOPRESS N hydrostatic borehole level transmitters are designed by \u003ca href=\"http:\/\/psctexas.com\/product-brands\/nivelco\/\"\u003eNIVELCO\u003c\/a\u003e to \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003emeasure the level\u003c\/a\u003e of clean or contaminated liquids. The \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/submersible-pressure-transducers\/\"\u003epressure sensor at the bottom of the probe measures the hydrostatic pressure (Phydr)\u003c\/a\u003eÂ of the liquid column above it and compares with the atmospheric pressure (Patm). The atmospheric pressure is led to the hydrostatic level transmitter through a breathing capillary. This capillary is equipped with a moisture filter that prevents moisture from reaching the electronics, which would decrease the accuracy of the measurement. This enables the atmospheric pressure to be subtracted from the measured pressure to get the hydrostatic pressure which is proportional to the height of the liquid column (h). The electronics convert the \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel transmitter\u003c\/a\u003e signal into an output signal. If temperature measurement of the liquid is needed beside the level measurement, a combined level + temperature \u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/submersible-level-transmitters\"\u003esubmersible level transmitter\u003c\/a\u003e should be used. \u003ch3\u003eScrew-in or Submersible Level Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant.jpg\"\u003e\u003cimg class=\"alignright wp-image-21664 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant.jpg\" alt=\"NIVOPRESS-N-nivelco-submersible-hydrostatic-level-transmitter-pressure-sensor-wastewater-tank-sewage-lift-station-chemical-plant\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e The installation and wiring of the transmitter is helped by the wide variety of accessories. A sewage adapter working on the principle of the diving bell can be snapped (NP) or can be screwed (NZ) into the place of the protecting cap to avoid the direct contact between the sensor and the measured contaminated liquid. Â An extra mechanical protection is built in the NZ type sewage adapters in the form of a mechanical filter. The N-500 are \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003eHazLoc rated models\u003c\/a\u003e that can be used in hazardous environments. The NZ screw-in model transmitters are recommended for applications where there is a risk of flooding. The NB \/ NG plastic housing models are designed for applications where an aggressive medium (e.g. saline solutions or seawater) could cause galvanic corrosion of the stainless steel body. \u003cul\u003e \u003cli\u003eHART communication\u003c\/li\u003e \u003cli\u003e2-wire or 3-wire versions\u003c\/li\u003e \u003cli\u003etwo 4-20 mA output (level + temperature)\u003c\/li\u003e \u003cli\u003ebuilt-in Pt100 temperature sensor\u003c\/li\u003e \u003cli\u003eover-voltage and inverse polarity protection\u003c\/li\u003e \u003cli\u003eHazLoc ratings available: explosion proof, ATEX (Ex ia)\u003c\/li\u003e \u003cli\u003esubmersible or screw-in types\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eNIVOPRESS N Hydrostatic Level Transmitter Model Line Up\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21662 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up.jpg\" alt=\"NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-level-meter-model-line-up\" width=\"1000\" height=\"811\"\u003e\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"page\" title=\"Page 2\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable class=\"nv-product-specs\"\u003e \u003ctbody\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e12-30 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e-22 to 140ËF\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e0 to 1,150 ft\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e4-20 mA + HART, 0-10 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68\u003c\/a\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"ng-scope\"\u003e \u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e \u003ctd class=\"ng-binding\"\u003e\n\u003ca href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" rel=\"nofollow noopener\"\u003eATEX\u003c\/a\u003e, UKCA Ex\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eCommon Uses of NIVOPRESS N Submersible Hydrostatic Level Transmitter\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical.jpg\"\u003e\u003cimg class=\"alignnone wp-image-21672 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical.jpg\" alt=\"NIVOPRESS-N-nivelco-distributor-submersible-hydrostatic-level-transmitter-pressure-sensor-non-clogging-wastewater-tank-sewage-lift-station-chemical\" width=\"1000\" height=\"576\"\u003e\u003c\/a\u003e \u003cul\u003e \u003cli\u003elevel metering of small diameter pipes, sewage water, saline solutions, sea water, potable water tanks, etc.\u003c\/li\u003e \u003cli\u003eborehole transmitter for the \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003ewater industry\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003ecan be certified for \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003epotable water, revenue water\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003elevel\u003c\/a\u003e and \u003ca href=\"https:\/\/psctexas.com\/product-category\/temperature\/\"\u003etemperature measurement\u003c\/a\u003e of \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003edrinking water wells, tanks, pools\u003c\/a\u003e, etc.\u003c\/li\u003e \u003cli\u003esubmersible pump control\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/submersible-level-transmitters\"\u003escrew-in submersible model\u003c\/a\u003e with \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68 protection\u003c\/a\u003e for applications with risk of flooding\u003c\/li\u003e \u003cli\u003eclean or slightly contaminated liquids\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003esewage and wastewater\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003edraw-down protection\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003esewage lift station control\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/chemicals\/\"\u003echemical industry\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878394617987,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOPRESS-N-submersible-hydrostatic-level-transmitter-pressure-sensor-lift-station-sensor-psc-texas-oklahoma-louisiana.png?v=1763385952"},{"product_id":"nivoflip-bypass-magnetic-level-indicator-mli","title":"NIVOFLIP Bypass Magnetic Level Indicator (MLI)","description":"\u003cul\u003e\n\u003cli\u003eoperation without power supply\u003c\/li\u003e\n\u003cli\u003eclearly visible display\u003c\/li\u003e\n\u003cli\u003estainless steel bypass chamber\u003c\/li\u003e\n\u003cli\u003e±0.4\" accuracy\u003c\/li\u003e\n\u003cli\u003e5 year manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eHazLoc ratings:\n\u003cul\u003e\n\u003cli\u003eexplosion-proof models\u003c\/li\u003e\n\u003cli\u003ePED certificate\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" title=\"ATEX Certification Standards\"\u003eATEX\u003c\/a\u003e (Ex d e m Gb)\u003c\/li\u003e\n\u003cli\u003eATEX (Ex h Ga\/Gb)\u003c\/li\u003e\n\u003cli\u003eFM Approval, Class 1 Div 1 (coming soon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNIVOFLIP Bypass Liquid Level Indicator\u003c\/h2\u003e\n\u003cp\u003eThe NIVOFLIP is a bypass level indicator manufactured by NIVELCO and is commonly paired with other level instrumentation such as switches and transmitters. The fluid level in the bypass chamber is the same as in the tank. The welded bypass chamber and the tank form one pressurized system, so the float containing a magnet rises and descends with the fluid level. The properly polarized magnet in the float topples the two-toned plates with the colored magnetic caps through the stainless steel tube's wall, indicating the fluid level. The plates with different color codes on the 100 mm (3.94\") under the lower stem provide a visual error message when fluid levels drop below the instrument's lower connecting point.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eerror indication\u003c\/li\u003e\n\u003cli\u003eoptional MAK−100 \/ MAK−200 strap-on level switches\u003c\/li\u003e\n\u003cli\u003eoptional magnetostrictive level transmitter\u003c\/li\u003e\n\u003cli\u003ealuminum or stainless steel lamella housing\u003c\/li\u003e\n\u003cli\u003estainless steel or titanium float\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eUsing NIVOFLIP with Level Switches and Level Transmitters\u003c\/h2\u003e\n\u003cp\u003eNIVOFLIP bypass liquid level indicator can be equipped with positionable external level switches to provide level limit switching. For level switches, the minimal liquid density should exceed the default value specified in the data sheet by 0.1 kg\/dm\u003csup\u003e3\u003c\/sup\u003e. For jobs requiring more accuracy than that of the magnetic flaps, high precision NIVOTRACK M–500 magnetostrictive level transmitters are recommended for use. Equipped with OIML R 85 certified NIVOTRACK, the measurement system is suitable for custody transfer measurements. The floatless rigid probe magnetostrictive transmitter can be mounted externally to the bypass chamber with clamps. All optional units are operated via magnetic coupling, there is no direct contact with the measured material. The MAK−100 model magnetic level switches are optional accessories for NIVOFLIP bypass level indicators. The float in the stainless steel bypass tube follows the level of the measured liquid. The float (permanent magnet) operates the positionable MAK−100 level switch via magnetic coupling and provides a non-contact signal transfer to the switch. There should be at least 100 mm (~4\") distance between two switching points.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUsing NIVELCO NIVOTRACK Level Transmitter with NIVOFLIP Level Indicator\u003c\/h3\u003e\n\u003cdiv title=\"Page 5\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003eNIVOTRACK magnetostrictive level transmitters are an ideal solution for high accuracy measurement of liquids. Its high precision, 0.1 mm or 1 mm (0.004\" or 0.04\") resolution, renders the NIVOTRACK suitable even for custody transfer measurement of liquids such as fuels, solvents, alcohol derivatives, etc. When ordered with the NIVOFLIP Magnetic Level Indicator, magnetostrictive transmitters are factory calibrated to the bypass tube and the magnetic float. The transmitter is fixed with pipe clamps and aluminum spacers.\n\u003cdiv title=\"Page 6\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003eThe length of the magnetostrictive level transmitter's probe should be 300 \/ 400 mm (11.8 \/ 15.75\") longer than the center to center distance of the bypass tube, depending on float type. The level transmitter is placed onto the bypass tube so that the top of the magnetostrictive probe is at the same height as the bypass tube's top. The end of the probe should extend the inverse polarized error indication flaps with 20 \/ 40 mm (0.78 \/ 1.57\"). The supplied aluminum spacers are fixed with hex socket set screws and they are mounted to the bypass tube with pipe clamps. In case of the high temperature models, there is a ceramic fiber insulation blanket between the magnetostrictive probe and the bypass tube. High temperature versions have ceramic fiber insulator fabric between the bypass tube and the probe of the level transmitter.\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eFlange Distance\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e1.65-18 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e-76 to 482˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eMedium Density\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e0.6 specific gravity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003emax. 1450 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eDIN, ANSI flanges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003ePED, \u003ca rel=\"nofollow noopener\" href=\"https:\/\/www.ul.com\/insights\/hazardous-locations-united-kingdom-market-access\" target=\"_blank\" title=\"ATEX Certification Standards\"\u003eATEX\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eCommon Uses of NIVOFLIP Bypass Liquid Level Indicator\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eoil and energy sector\u003c\/li\u003e\n\u003cli\u003echemical and petrochemical industry\u003c\/li\u003e\n\u003cli\u003epower generation\u003c\/li\u003e\n\u003cli\u003epressurized vessels, boilers, and tanks\u003c\/li\u003e\n\u003cli\u003epower plants\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/utilities\/wastewater-water-treatment\/\"\u003erevenue water and wastewater industry\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878394650755,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOFLIP-bypass-level-indicator-nivelco-distributor-level-measurement-instrumentation-process-solutions-corp.png?v=1763385953"},{"product_id":"circular-high-output-high-bay-lighting","title":"Circular High Output, High Bay Lighting","description":"\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003eOur standard Circular High Bay Lighting Series (CHS-H) is a versatile and durable indoor fixture that come in six sizes with two optional reflectors that are field installable. It is lightweight and installation is easy enough for a single person. This high bay lighting is an excellent choice of \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/indoor-lighting\/\"\u003eindoor light\u003c\/a\u003e from \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003eHorner Lighting Group\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eoutput of 50,000 to 76,800 lumens\u003c\/li\u003e\n\u003cli\u003eengineered with quality, space-age materials\u003c\/li\u003e\n\u003cli\u003etraditional round profile is light weight and easy to install\u003c\/li\u003e\n\u003cli\u003equickly mount via hook (standard) or ring\u003c\/li\u003e\n\u003cli\u003eunique, optional junction box enables flexible wire termination\u003c\/li\u003e\n\u003cli\u003e277\/480 VAC option available\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 Dust and Water Protection\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eUL wet-rated\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Output High Bay Lighting\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.hornerlighting.com\/wp-content\/uploads\/2019\/03\/CHS480H_Bottom.jpg\"\u003e\u003cimg class=\"alignright\" src=\"https:\/\/www.hornerlighting.com\/wp-content\/uploads\/2019\/03\/CHS480H_Bottom.jpg\" alt=\"high-bay-lighting-horner-industrial-light-group-process-solutions-corp\" width=\"3338\" height=\"3340\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e80 CRI standard enhances color and clarity\u003c\/li\u003e\n\u003cli\u003epowerful light engine creates even output with 4 different distributions\u003c\/li\u003e\n\u003cli\u003eoptional aluminum reflectors of either 60Ë or a 70Ë acrylic\u003c\/li\u003e\n\u003cli\u003eoptional acrylic lens provides control, minimizing potential for glare\u003c\/li\u003e\n\u003cli\u003etypical mounting heights of 10 to 60â\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Quality, Affordable Commercial Lighting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etypical payback of 12-24 months\u003c\/li\u003e\n\u003cli\u003e0-10 dimming standard\u003c\/li\u003e\n\u003cli\u003eup to 160 lumens\/watt\u003c\/li\u003e\n\u003cli\u003epotential for rebate saving through DLC certifications: Â \u003ca href=\"www.designlights.org\" rel=\"nofollow noopener\" target=\"_blank\"\u003ewww.designlights.org\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eutilize optional motion and\/or daylight sensors for additional energy savings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCircular High Output, High Bay Lighting Model Line Up\u003c\/h3\u003e\n\u003ctable id=\"tablepress-115\" class=\"tablepress tablepress-id-115\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003eModel\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003eWeight\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003eDimensions (LxWxH inches)\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003eCRI\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003eCCT\u003c\/th\u003e\n\u003cth class=\"column-6\"\u003eLumens\u003c\/th\u003e\n\u003cth class=\"column-7\"\u003eTotal Watts\u003c\/th\u003e\n\u003cth class=\"column-8\"\u003eLumens \/ Watts\u003c\/th\u003e\n\u003cth class=\"column-9\"\u003eL70 (hr)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-CHS320H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e14 lbs.\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e11.75 x 11.75 x 9.25\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e80\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e5000k\u003c\/td\u003e\n\u003ctd class=\"column-6\"\u003e49,600\u003c\/td\u003e\n\u003ctd class=\"column-7\"\u003e328\u003c\/td\u003e\n\u003ctd class=\"column-8\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-9\"\u003e\u0026gt;192,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-CHS480H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e24 lbs.\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e15.75 x 5.75 x 10.5\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e80\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e5000k\u003c\/td\u003e\n\u003ctd class=\"column-6\"\u003e76,800\u003c\/td\u003e\n\u003ctd class=\"column-7\"\u003e484\u003c\/td\u003e\n\u003ctd class=\"column-8\"\u003e159\u003c\/td\u003e\n\u003ctd class=\"column-9\"\u003e\u0026gt;225,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch5\u003ePower Options\u003c\/h5\u003e\n\u003ctable id=\"tablepress-68\" class=\"tablepress tablepress-id-68\"\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003ePart Number Adder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e - built on the light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eP1 (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eON\/OFF 120~277 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eP2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAccessories\u003c\/h5\u003e\n\u003ctable id=\"tablepress-68\" class=\"tablepress tablepress-id-68\"\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-PLG-G4-CHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eWire harness 277V L7-15 AC twist cord with connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-PLG-G3-CHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eWire harness 120V 5-15 AC cord with connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-PLG-G0-CHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eWire harness cable with connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-PLG-CNP-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e480 VAC, 10' Power Cord WIP; (recommended for P2 fixtures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-LEN-CHSH-60D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eAcrylic Optical lens for replacing standard lens, 60 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-WHM-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eTwo Adjustable Single Wire Mounts with One hook on each, 5 ft Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-HBRH-RAL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e1 high bay aluminum reflector with 60Â° angle light distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-HBRH-RAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e1 high bay acrylic reflector with 70Â° angle light distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-BKT-CHB-PD1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePendant Mount Option for P1 Circular High Bay models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-BKT-CHB-PD2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePendant Mount Option for P2 Circular High Bay models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-18 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eETG-CTL-SEN-MOT-CHSH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eOn\/Off Motion Sensor, Fixture or Reflector (120~277 VAC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommon Areas that Use High Bay Lighting\u003c\/h3\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003egrocery stores\u003c\/li\u003e\n\u003cli\u003ewarehouses\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/manufacturing\/\"\u003emanufacturing facilities\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003edepartment stores\u003c\/li\u003e\n\u003cli\u003esport stadiums\u003c\/li\u003e\n\u003cli\u003enatatoriums\u003c\/li\u003e\n\u003cli\u003eindustrial garages\u003c\/li\u003e\n\u003cli\u003ehangars\u003c\/li\u003e\n\u003cli\u003eindoor storage facilities\u003c\/li\u003e\n\u003cli\u003egymnasiums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance Tips\u003c\/h3\u003e\n\u003cdiv class=\"page\" title=\"Page 2\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003col\u003e\n\u003cli\u003eTo maintain efficiency, the glass lens should be cleaned with a mild soap or neutral PH cleaner.\u003c\/li\u003e\n\u003cli\u003eAbrasives or cleaners containing chlorinated or aromatic hydrocarbons should not be used.\u003c\/li\u003e\n\u003cli\u003eOnce clean, rinse with cold water and wipe dry with a soft cloth.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Horner Automation","offers":[{"title":"Default Title","offer_id":45878394912899,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/CHS-H-circular-high-bay-high-output-lighting-horner-distributor-online-affordable-powerful-commercial-lighting-UL-Listed-quality-lights-process-solutions-corp.jpg?v=1763385957"},{"product_id":"x5-prime-grow-light-control-system","title":"X5 Prime Grow Light Control System","description":"\u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The X5 Prime Grow Light Controller is a critical component for building your own \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/lighting-control-systems\/\"\u003egrow light control system\u003c\/a\u003e. With built-in I\/O and expansion options, operators can program this powerful automation controller to set grow light cycles, operate fans and humidifiers, control watering systems, monitor and adjust for temperature, and much more. Its ethernet connectivity options allow remote control and monitoring of your operation and is perfect for data logging to help improve your process over time and track the growth of your plants and your business as well. \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eAll-in-One Control\u003c\/strong\u003e performs all machine functions in a unified hardware design: Logic Control, Operator Interface, I\/O, and Networking\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eModern Memory Architecture\u003c\/strong\u003eÂ based on a custom designed SOM \u003cem\u003e(System on Module)\u003c\/em\u003e utilizing a powerful ARM microprocessor and 100% non-volatile memory for reliability\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHigh Performance Logic Engine\u003c\/strong\u003e fast scan times solving user logic using Variable-based Advanced Ladder logic or the IEC 6-1131 language set\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOnline Programming\u003c\/strong\u003e make logic changes without stopping the controller\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHigh Resolution Color Touchscreen\u003c\/strong\u003e for detailed graphics and nearly instantaneous screen updates\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAdvanced High Speed Counter\u003c\/strong\u003e four built-in counters supporting frequencies over 500 kHz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial Ethernet and Remote ControlÂ \u003c\/strong\u003eEthernet IP, \u003ca href=\"https:\/\/www.modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus TCP\u003c\/a\u003e and \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet IP\u003c\/a\u003e; FTP file transfer, Email, \u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e* for web-based Remote Monitoring, and Push data to the cloud with MQTT* Sparkplug\u003cem\u003eÂ (*\u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e \/ MQTT require one-time license)\u003c\/em\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePlug and Play Data Logging\u003c\/strong\u003eÂ record machine and process variables to microSD or USB Flash Drive\u003c\/li\u003e \u003c\/ul\u003e [embed]https:\/\/www.youtube.com\/watch?v=vuhfGnSBcDU[\/embed] \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/grow-lighting\/\"\u003eGrow Light Control System for Greenhouses, Indoor Farming\u003c\/a\u003e\u003c\/h3\u003e \u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThe X5 Prime grow light \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/\"\u003eautomation controller\u003c\/a\u003e really packs a big picture into an overall small package. With just a 4.6\" x 3.5\" cutout, this 4.3\" wide aspect screen is very friendly, intuitive, and clear. By incorporating our hidden soft key technology, you can use the entire screen to illustrate your specific applications.\u003c\/span\u003e\u003c\/p\u003e \u003cp class=\"p1\"\u003eWith full integration of hardware and software, \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/xl-prime-series\/\"\u003ethe XL Prime Series\u003c\/a\u003e offers easy programming, installation, development and set-up. Our controllers have a small footprint and can easily retrofit into an existing system with little effort. The XL Prime Series is not limited to its on-board I\/O. Many variations of the \u003ca href=\"https:\/\/psctexas.com\/product\/horner-ocs-io-input-output\/\"\u003eOCS-I\/O\u003c\/a\u003e can be connect via CsCAN, Ethernet, or Modbus. RTU \/ Modbus based SmartMod I\/O is also a cost-effective means of adding a small amount of analog I\/O.\u003c\/p\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/grow-lighting\/\"\u003e\u003cimg class=\"alignright wp-image-21731 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/commercial-grow-lights-hemp-horner-automation-indoor-greenhouse-vegetable-lights-commercial-hydroponics-growing-psc-texas-oklahoma-louisiana.png\" alt=\"commercial-grow-lights-hemp-horner-automation-indoor-greenhouse-vegetable-lights-commercial-hydroponics-growing-psc-texas-oklahoma-louisiana\" width=\"500\" height=\"500\"\u003e\u003c\/a\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The XL Prime series utilizes microSDTM Data Storage Memory, ideal for data logging, machine recipes, and application files. \u003cdiv class=\"page\" title=\"Page 15\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cul\u003e \u003cli\u003eBright, 65K color graphical touch sensing LCD display\u003c\/li\u003e \u003cli\u003eDisplay of complex graphical objects including trends, gauges, meters and animations\u003c\/li\u003e \u003cli\u003eHigh performance graphic processing\u003c\/li\u003e \u003cli\u003eAdvanced control capabilities including floating point, multiple auto-tuning PID loops and string handling capabilities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eAdvanced Control and Performance\u003c\/h3\u003e \u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eIn an effort to make implementing \u003ca href=\"https:\/\/psctexas.com\/product-brands\/horner\/\"\u003eHorner OCS controllers\u003c\/a\u003e as seamless and user-friendly as possible, we have selected a streamlined set of on-board I\/O. Four digital inputs, four digital outputs, and four analog inputs make automating your applications, and your organization, as simple as the push of a (virtual) button.\u003c\/span\u003e\u003c\/p\u003e \u003cp class=\"p1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eWhen it comes to speed, resolution, and technical capabilities, the X5 Prime is leading the way. We have developed some entirely new design techniques, a suite of capabilities similar to our more established \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/xl-series\/\"\u003eXL Series of automation controllers\u003c\/a\u003e, and unprecedented acceptance across an array of commercial and industrial applications. In the market of fixed I\/O, web-compatible controllers, the X5 Prime is unmatched.\u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFull featured, built-in I\/O including high resolution analog, high speed counter inputs, and PWM outputs\u003c\/li\u003e \u003cli\u003eAdvanced high speed I\/O capabilities\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/cscape-10-plc-software\/\"\u003eCscape programming software\u003c\/a\u003e that allows all aspects of the X5 Prime OCS to be programmed and configured from one integrated application\u003c\/li\u003e \u003cli\u003eOn board Ethernet port (10\/100Mbps) for Cscape programming and application defined communication with Auto MDI \/ MDI-X\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMonitor and Data Logging Grow Light Control System\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/xl-prime-series\/\"\u003eThe XL Prime Series\u003c\/a\u003e is designed as a modular system for easy selection and growth. CsCAN (CAN Based) high speed networking and Modbus RTU networking capabilities are standard in all Prime Series controllers. Ethernet is standard in XL Prime Series controllers and available as an optional component in all other models. \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/input-output-io\/\"\u003eRemote I\/O\u003c\/a\u003e options offer high performance, accurate analog, and easy-to-configure digital only modules. Horner I\/O has flexible communication options that easily expand current systems. \u003cul\u003e \u003cli\u003eRemovable media for FAT32 format (up to 2TB) of storage of programs, data logging or screen captures\u003c\/li\u003e \u003cli\u003eCsCAN networking port for communication with remote I\/O, other controllers, or PCs\u003c\/li\u003e \u003cli\u003eHigh speed USB port for communication with PCs and programming of controller\u003c\/li\u003e \u003cli\u003eConfigurable serial protocols for communication to drives, PLCs, or other serial peripherals\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhite Label Greenhouse Controller for OEMs\u003c\/h3\u003e \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The XL Prime Series is a white-label product, which means that other companies can rebrand these units. Also, they fit in most cabinets, console designs, and color schemes, so they can be easily integrated into greenhouses and other indoor growing environments. A customized overlay can be added to match the language, logo, and industry terms of OEMs. This gives the flexibility to use the XL Prime series in any application. \u003cdiv class=\"page\" title=\"Page 1\"\u003e \u003cdiv class=\"section\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e for Remote Monitoring and Control\u003c\/h3\u003e With \u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eHorner WebMI\u003c\/a\u003e, you can monitor and control plant data from the palm of your hand. Published directly from the OCS Controller, WebMI allows the same or unique Web pages to be monitored and controlled from your computer, tablet, or other mobile device, supporting all of our controllers. Developed completely within our \u003ca href=\"https:\/\/psctexas.com\/product\/cscape-10-plc-software\/\"\u003eCscape environment\u003c\/a\u003e, WebMI allows for state-of-the-art HTML5 development without the need for web programming skills. The licensing and registration process is quick and simple while the benefits and affordability of WebMI will truly change your world. \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eX5 Prime Series Grow Light Control System Specifications\u003c\/h3\u003e \u003ch5\u003eCatalog Description\u003c\/h5\u003e X5 Prime Controller 4.3â³, 4 DC In, 4 DC Out, 4 Analog In (mA\/V) \u003ch5\u003eController\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-2 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eLadder Logic Memory\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e2 MB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-3 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eLogic Scan Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e0.02 mS\/K\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-4 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eRemovable Memory\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003emicroSD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eLocal Comment Storage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eFloating Point Support\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-7 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eAutoTune PID Capable\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eOperator Interface\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-10 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eCharacters \/ Pixels\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e480 x 272\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-11 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eDisplay Technology\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4.3\" TFT Color\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-12 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eCharacter Height\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eSelectable Fonts\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-13 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eNumber of Pages\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1023\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-14 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eFields or Objects per Page\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1023\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-15 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eTotal Keys\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e5 (on screen)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-16 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eFunction Keys\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4 (on screen)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-17 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eOEM Faceplate Available\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eInput \/ Output\u003c\/h5\u003e \u003ctable id=\"tablepress-327\" class=\"tablepress tablepress-id-327 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-1 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4 Inputs, 4 Outputs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-2 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eHigh Speed In\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4 @ 500kHz (4 signals)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-3 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eHigh Speed Out\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e2 PWM or Stepper Out\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-4 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eAnalog In\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4 12-bit\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eAnalog Out\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eâ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eTemperature In\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eâ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-7 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1 Port\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-20 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eBuilt-in I\/O Points\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e12\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-21 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eSmartStix, SmartRail, SmartBlock I\/O Support\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eyes, CsCAN and Ethernet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-22 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eDigital Inputs \/ Outputs, max\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e2048 \/ 2048\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-23 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eAnalog Inputs \/ Outputs, max\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e512 \/ 512\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-24 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eGeneral Purpose Registers (words)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e50,000 (50,000 retentive)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-25 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eGeneral Purpose Internal Coils (bits)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e32768 (16384 retentive)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eEthernet and Networking\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-28 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eEthernet Support\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003estandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-29 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eRemote Access\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e, HTTP or \u003ca href=\"https:\/\/psctexas.com\/product\/cscape-envision-rv\/\"\u003eEnvisionRV\u003c\/a\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-30 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eRemote File Access\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eFTP or \u003ca href=\"https:\/\/psctexas.com\/product\/cscape-envision-fx\/\"\u003eEnvisionFX\u003c\/a\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-31 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eIIoT Support\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eMQTT (Sparkplug)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-42 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eIntegrated CAN Networks\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-43 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eSupported CAN Networks\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eCsCAN, \u003ca href=\"https:\/\/www.can-cia.org\/canopen\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCANopen\u003c\/a\u003e (firmware change), DeviceNet Master (contact factory), \u003ca href=\"https:\/\/psctexas.com\/j1939-protocol-display-controllers\/\"\u003eSAE J1939\u003c\/a\u003e (contact factory)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-44 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMaximum CAN Distance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1,640 ft.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-45 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eProgramming over CAN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eSerial Communications\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-34 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eTotal Active Ports\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-35 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eRS-232 Ports \/ RS-485 Ports\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eRS-232 \/ RS-485 (1 of each)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-36 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003ePLC \/ Drive Protocols\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-37 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eRTU \/ Modbus Commander \/ Responder (Master \/ Slave)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-38 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eSerial ASCII In \/ Out\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-39 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eUSB Ports (A and Mini-B)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003ePhysical Dimensions\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-48 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e3.79â³ \/ 96.27 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-49 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e4.92â³ \/ 124.97 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-50 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eTotal Depth\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e1.4â³ \/ 35.8 mm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch5\u003eOperating Standards\u003c\/h5\u003e \u003ctable id=\"tablepress-328\" class=\"tablepress tablepress-id-328 tablepress-responsive\"\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-53 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e-10 to 60Â°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-54 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eHumidity (non-condensing)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e5 to 95%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-55 odd\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003eCE, Câ, \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eUL Class 1 Div II\u003c\/a\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-56 even\"\u003e \u003ctd class=\"column-1\"\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP66\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eUL Type 3R, 4, 4x, 12, 12k, 13\u003c\/a\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Horner Automation","offers":[{"title":"Default Title","offer_id":45878395043971,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/x7_ab7979d9-d8b2-4c67-98a8-e170d0d066db.jpg?v=1763385961"},{"product_id":"xl4-prime-industrial-lighting-control-system","title":"XL4 Prime Industrial Lighting Control System","description":"The XL4 Prime Industrial Light Controller is a critical component for building your own \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/lighting-control-systems\/\"\u003eindustrial lighting control system\u003c\/a\u003e. With built-in I\/O and expansion options, this powerful automation controller can program to set light cycles, operate fans, and also much more. This industrial lighting control device is ideal for example: \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003einspection lighting, greenhouses, commercial warehouses, manufacturing facilities, and more\u003c\/a\u003e. Its ethernet connectivity options allow remote control and monitoring of your operation and is perfect for data logging to help improve process efficiency as well as reduce energy waste. The XL Prime Series features all-in-one industrial lighting control and performs all machine functions in a unified hardware design. This includes the Logic Control, Operator Interface, I\/O, and Networking. Our \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/\"\u003eHMI controller\u003c\/a\u003e is designed with a modern memory architecture based on a custom designed SOM (System on Module) utilizing a powerful ARM microprocessor and 100% non-volatile memory for reliability. With high-performance logic engines, the XL4 Prime automation controller offers fast scan times. This solves user logic using Variable-based Advanced Ladder logic or the \u003ca href=\"https:\/\/psctexas.com\/august-is-iec-month-at-horner\/\"\u003eIEC 6-1131\u003c\/a\u003e language set. [embed]https:\/\/www.youtube.com\/watch?v=vuhfGnSBcDU[\/embed] \u003ch3\u003eOnline Programming and Remote Control\u003c\/h3\u003e Online programming is available through \u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e, MQTT, and the \u003ca href=\"https:\/\/psctexas.com\/product\/horner-app\/\"\u003eHorner App\u003c\/a\u003e, which also allows for remote control. It also enables users to make logic changes without stopping the controller. Communication relies on Ethernet IP, \u003ca href=\"https:\/\/www.modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus TCP\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet IP\u003c\/a\u003e, FTP file transfer, as well as email. Collected data can be logged including record machine and also process variables, which can be saved to a microSD or USB Flash Drive. \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003e\u003cimg class=\"alignright wp-image-26419 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/12\/industrial-led-lighting-fixtures-luminaires-horner-lights-process-solutions-corp-texas-300x300.png\" alt=\"industrial-led-lighting-fixtures-luminaires-horner-lights-process-solutions-corp-texas\" width=\"300\" height=\"300\"\u003e\u003c\/a\u003e \u003ch3\u003eXL4 Prime Industrial Lighting Control System\u003c\/h3\u003e The screen is a high-resolution color touchscreen that is capable of displaying detailed graphics and also provides nearly instantaneous screen updates. Furthermore, the \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/xl-prime-series\/\"\u003eXL Prime Series of automation controllers\u003c\/a\u003eÂ includes an advanced high-speed counter with four built-in counters supporting frequencies over 500 kHz. \u003ch3\u003eAdvanced Features of XL4 Prime Series Lighting Controller\u003c\/h3\u003e \u003cul\u003e \u003cli\u003elogic engine features 1MB of application memory with a 0.02mS\/K logic scan\u003c\/li\u003e \u003cli\u003esupports online programming mode for making logic changes on the fly without going thru stop mode\u003c\/li\u003e \u003cli\u003eoperator interface features include a 320Ã240 LCD TFT color graphics display with a high resolution resistive touchscreen, 4 function keys as well as a system key\u003c\/li\u003e \u003cli\u003eUSB 2.0 on-the-go port (mini-B 5pin) is available for programming\u003c\/li\u003e \u003cli\u003ealso available with a USB 2.0 host port (A) for exchanging files via USB FLASH drives\u003c\/li\u003e \u003cli\u003eone (1) RS-232 and one (1) 485 port support RTU \/ Modbus Commander \/ Responder (Master \/ Slave), ASCII In\/Out, and PLC \/ Drive downloadable protocols\u003c\/li\u003e \u003cli\u003enetworking features include a built-in 10\/100 Ethernet port, as well as an integrated CsCAN port\u003c\/li\u003e \u003cli\u003eall units feature a microSD slot, supporting at least 32GB\u003c\/li\u003e \u003cli\u003eenvironmental rating: \u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA\u003c\/a\u003eÂ \u0026amp;Â \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eUL Type 1, 3R, 4, 4x, 12, 12k, 13, ABS\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eproduct certifications: CE, C', \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eUL Class 1 Div II\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eXL4 Prime Industrial Lighting Control System Model Lineup\u003c\/h3\u003e \u003ctable id=\"tablepress-281\" class=\"tablepress tablepress-id-281 tablepress-responsive\"\u003e \u003cthead\u003e \u003ctr class=\"row-1 odd\"\u003e \u003cth class=\"column-1\"\u003e\u003cstrong\u003eController Model\u003c\/strong\u003e\u003c\/th\u003e \u003cth class=\"column-2\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody class=\"row-hover\"\u003e \u003ctr class=\"row-2 even\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E0\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eNo built-in I\/O\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-3 odd\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E2\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e12 DC in, 6 Relay Out, 4 â 12-bit Analog In\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-4 even\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E3\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e12 DC in, 12 DC Out, 2 â 12-bit Analog In\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-5 odd\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E4\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e24 DC in, 16 DC Out, 2 â 12-bit Analog In\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-6 even\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E5\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e12 DC in, 12 DC Out, 2 â 14\/16-bit Analog In (mA\/V\/Tc\/mV\/RTD), 2 â 12-bit Analog Out\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-7 odd\"\u003e \u003ctd class=\"column-1\"\u003eHE-XPC1E6\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e12 DC in, 12 DC Out, 6 â 14\/17-bit Analog In (mA\/V\/Tc\/mV\/RTD), 4 â 12-bit Analog Out\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e Standard models are available from our online store. For special order options (below), please contact our sales team \u003ca href=\"tel:12814913833\"\u003e(281) 491-3833\u003c\/a\u003e or \u003ca href=\"mailto:sales@psctexas.com\"\u003esales@psctexas.com\u003c\/a\u003e for pricing as well as lead time support. \u003ch3\u003eSpecial Order - XL4 Prime Lighting Controller\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr class=\"row-10 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ePart Number Extension\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-11 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eThermistor option; add -10 to the part number for Thermistor support for Analog Inputs 1 \u0026amp; 2; models 2, 3, and 4 only.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-12 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-14\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eThermistor option; add -14 to the part number for (4) Channel Thermistor support; model 2 only.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-13 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-22\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eWith Display Heater\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-14 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-33\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eDeviceNet Master option; add -33 to the part number; adds DeviceNet Master Support (Polled \u0026amp; Explicit Connections only) and also removes CsCAN support.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-15 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-44\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/j1939-protocol-display-controllers\/\"\u003eSAE J1939\u003c\/a\u003e option; add -44 part number extension; adds SAE J1939 communications and also removes CsCAN support.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-16 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-200\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eAdds \u003ca href=\"https:\/\/www.can-cia.org\/canopen\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCANOpen\u003c\/a\u003e Firmware, pre-loaded; and also removes CsCAN support.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-17 odd\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-602\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eAdds screw type I\/O terminals and also removes spring type terminals; model 6 only.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-18 even\"\u003e \u003ctd class=\"column-1\" style=\"text-align: center;\"\u003e\u003cstrong\u003e-603\u003c\/strong\u003e\u003c\/td\u003e \u003ctd class=\"column-2\"\u003eAdds display heater and screw type I\/O terminals; and also removes spring type terminals; model 6 only.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr class=\"row-19 odd\"\u003e \u003ctd class=\"column-1\" colspan=\"2\"\u003e(*) Not available for purchase on the web store. Please call for product availability. Lead time on special order products is 4-6 weeks.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Horner Automation","offers":[{"title":"HE-XPC1E0","offer_id":45878395076739,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPC1E2","offer_id":45878395109507,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPC1E3","offer_id":45878395142275,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPC1E4","offer_id":45878395175043,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPC1E5","offer_id":45878395207811,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPC1E6","offer_id":45878395240579,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/XLTe-Horner-Automation-Controller-Programmable-Logic-Controller-PLC-HMI-online-procurement_7346a9cc-0ae3-4415-9c12-8ab7089cd791.jpg?v=1763385963"},{"product_id":"xl7-prime-industrial-lighting-controller","title":"XL7 Prime, Industrial Lighting Controller","description":"\u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e The XL7 Prime Industrial Lighting Controller is a critical component for building your own \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/lighting-control-systems\/\"\u003eindustrial light control system\u003c\/a\u003e. With built-in I\/O and expansion options, this powerful automation controller can program to set light cycles, operate fans, and much more. These lighting controllers are ideal for \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003einspection lighting, task lights, commercial warehouses, manufacturing facilities, grow lights in greenhouses, and more\u003c\/a\u003e. Its ethernet connectivity options allow control and remote monitoring of your operation and is also capable of data logging to help improve process efficiency and reduce energy waste.   [embed]https:\/\/www.youtube.com\/watch?v=vuhfGnSBcDU[\/embed]   The XL7 Prime OCS HMI automation controller is an \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/\"\u003eall-in-one industrial control device\u003c\/a\u003e. These PLCs from \u003ca href=\"https:\/\/psctexas.com\/product-brands\/horner\/\"\u003eHorner Automation\u003c\/a\u003e combine control, user interface, \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/input-output-io\/\"\u003eI\/O\u003c\/a\u003e, and networking into a single, integrated package. Unique features of the XL7 Prime OCS include: \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"page\" title=\"Page 15\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"page\" title=\"Page 15\"\u003e \u003cdiv class=\"layoutArea\"\u003e \u003cdiv class=\"column\"\u003e \u003cul\u003e \u003cli\u003ebright, 65,536 color graphical touch sensing LCD display\u003c\/li\u003e \u003cli\u003ehigh performance graphic processing and display of complex objects including trends, gauges, meters, as well as animations\u003c\/li\u003e \u003cli\u003eadvanced control capabilities including floating point, multiple auto-tuning PID loops, and also string handling capabilities\u003c\/li\u003e \u003cli\u003eremovable media for 32GB of storage of programs, data logging, in addition to screen captures\u003c\/li\u003e \u003cli\u003eCsCAN networking port for communication with remote I\/O, other controllers, or also PCs\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/product-category\/industrial-lighting\/\"\u003e\u003cimg class=\"alignright wp-image-26093 size-medium\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2024\/11\/Horner-Lighting-Group-Outdoor-Lighting-LED-Lights-Sports-Light-Spotlight-Parking-Lot-Lighting-Process-Solutions-Texas-300x300.png\" alt=\"Horner-Lighting-Group-Outdoor-Lighting-LED-Lights-Sports-Light-Spotlight-Parking-Lot-Lighting-Process-Solutions-Texas\" width=\"300\" height=\"300\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eXL7 Prime Series Industrial Lighting Controller\u003c\/h3\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e Our industrial lighting controller models offer a modern memory architecture with a custom design SOM (System on Module). They utilize a powerful ARM microprocessor and 100% non-volatile memory for reliability. With high-performance logic engines, these automation controllers offer fast scan times, solving user logic using Variable-based Advanced Ladder logic or the \u003ca href=\"https:\/\/psctexas.com\/august-is-iec-month-at-horner\/\"\u003eIEC 6-1131\u003c\/a\u003e language set. HE-Logic engine features 1MB of application memory with a 0.02mS\/K logic scan. It also supports an Online Programming Mode for making logic changes on the fly without going thru stop mode. \u003cul\u003e \u003cli\u003ehigh speed USB port for communication with PCs and programming of the industrial lighting controller\u003c\/li\u003e \u003cli\u003econfigurable serial protocols for communication to drives, PLCs, or also other serial peripherals\u003c\/li\u003e \u003cli\u003efull featured, built-in I\/O including high resolution analog, thermocouple, RTD, high speed counters, PWM outputs, as well as relays \u003cem\u003e(depending upon the XL7 Prime OCS model)\u003c\/em\u003e\n\u003c\/li\u003e \u003cli\u003eadvanced high speed I\/O capabilities\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/cscape-10-plc-software\/\"\u003eCscape programming software\u003c\/a\u003e that allows all programming and configuration aspects of the XL7 Prime OCS from one application\u003c\/li\u003e \u003cli\u003eoptional communication add-on modules\u003c\/li\u003e \u003cli\u003eon board Ethernet port (10\/100Mbps) for Cscape programming and application communication with Auto MDI \/ MDI-X\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/hornerautomation.com\/wp-content\/uploads\/2017\/08\/app_signin_blog-01.jpg\"\u003e\u003cimg class=\"alignright\" src=\"https:\/\/hornerautomation.com\/wp-content\/uploads\/2017\/08\/app_signin_blog-01.jpg\" alt=\"horner-industrial-lighting-controller-xl7-prime-series\" width=\"600\" height=\"600\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eIndustrial Lighting Control with Online Programming and Remote Control\u003c\/h3\u003e Online programming of our industrial lighting controller devices is made available through \u003ca href=\"https:\/\/psctexas.com\/product\/webmi\/\"\u003eWebMI\u003c\/a\u003e, MQTT, and the \u003ca href=\"https:\/\/psctexas.com\/product\/horner-app\/\"\u003eHorner App\u003c\/a\u003e, which also allows for remote control, and enables users toÂ make logic changes without stopping the controller. Communication is based on Ethernet IP, \u003ca href=\"http:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus TCP\u003c\/a\u003e, \u003ca href=\"https:\/\/bacnet.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eBACnet IP\u003c\/a\u003e, FTP file transfer, or email. Collected data can be logged including record machine and process variables, which can save to a microSD or USB Flash Drive. \u003ch3 style=\"text-align: left;\"\u003eFast Processing and Response Time\u003c\/h3\u003e The screen is a high-resolution color touchscreen that is capable of displayingÂ detailed graphics and nearly instantaneous screen updates. The \u003ca href=\"https:\/\/psctexas.com\/product-category\/controller-plc-hmi\/hmi-controllers\/xl-prime-series\/\"\u003eXL Prime Series of automation controllers\u003c\/a\u003eÂ also includes an advanced high-speed counter withÂ four built-in counters supporting frequencies over 500 kHz.","brand":"Horner Automation","offers":[{"title":"HE-XPW1E0","offer_id":45878395273347,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPW1E2","offer_id":45878395306115,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPW1E3","offer_id":45878395338883,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPW1E4","offer_id":45878395371651,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPW1E5","offer_id":45878395404419,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"HE-XPW1E6","offer_id":45878395437187,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/XL7_HL-01-400x400-1_1ed31c09-667c-4f99-a4f4-5297ce5b27d7.png?v=1763385964"},{"product_id":"nivoswitch-level-switch-for-solids-vibrating-fork","title":"NIVOSWITCH Level Switch for Solids, Vibrating Fork","description":"\u003cp style=\"margin-top: 30px;\"\u003eThe NIVOSWITCH level switch for solids features a non-parallel vibrating fork and is suitable for level detection of granular or powder solids. With mounting on pipes, silos, tanks, or hopper bins for filling and emptying, these level switches, from NIVELCO, can generate fail-safe alarms, providing overfill and dry run protection. It uses an electronic circuit that excites the fork probe, making it vibrate. As the medium reaches and covers the fork its vibration changes or stops. The fork will start vibrating freely again as the medium sets it free. The electronics sense the change of vibration and gives output signal after a selected delay.\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px;\"\u003e \u003c\/p\u003e\n\u003ch2\u003eNIVOSWITCH Vibrating Fork Level Switch for Solids\u003c\/h2\u003e\n\u003cp\u003eA version with plastic coating is ideal in aggressive mediums, and a high polish version is best for use with abrasive mediums. The PNP\/NPN transistor output versions can connect directly to a PLC, or relay unit. NIVOSWITCH vibrating forks are able to solve switching tasks of high current loads with the help of UNICONT PKK switching amplifiers. The UNICONT PKK-312-8 Ex intrinsically safe switching unit is designed to serve Ex rated vibrating forks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eno moving parts\u003c\/li\u003e\n\u003cli\u003eself-cleaning in most mediums\u003c\/li\u003e\n\u003cli\u003estainless steel probes\u003c\/li\u003e\n\u003cli\u003epipe extension up to 10 feet\u003c\/li\u003e\n\u003cli\u003evarious output configurations\u003c\/li\u003e\n\u003cli\u003eselectable density\u003c\/li\u003e\n\u003cli\u003ehigh or low fail-safe mode\u003c\/li\u003e\n\u003cli\u003eplastic, aluminum, or stainless steel housing\u003c\/li\u003e\n\u003cli\u003edust-Ex variants available\u003c\/li\u003e\n\u003cli\u003e3 year manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHazardous Area Rating Level Switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX: Ex ia G, Ex d G\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003e20-255 V AC, 20-60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003e−40 to 158˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003e−40 to 266˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003emaximum 580 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003e1 or 2 relays (SPDT), 2-wire AC or DC, transistor (PNP, NPN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003e1\", 1½\", 2\" or flanges or hygienic fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Ratings for Industrial Instrumentation\" rel=\"noopener\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003eIP67, IP68, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth style=\"text-align: center;\" class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" class=\"ng-binding\"\u003eATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch2\u003eCommon Uses of Level Switches\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003egranules and powders with minimum 0.01 specific gravity\u003c\/li\u003e\n\u003cli\u003echemical industry\u003c\/li\u003e\n\u003cli\u003efood and beverage\u003c\/li\u003e\n\u003cli\u003epower plants\u003c\/li\u003e\n\u003cli\u003epaper mills\u003c\/li\u003e\n\u003cli\u003eplastic industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ccenter\u003e\u003cbr\u003e\u003c\/center\u003e\n\u003ch2\u003eNIVOSWITCH Series Vibrating Fork Level Switch Model Line-Up\u003c\/h2\u003e\n\u003cp\u003eType selection is aided by this table for choosing the proper version to a given level switching task. Most essential aspect is the consistency of the measurement medium.\u003c\/p\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878421160067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/NIVOSWITCH-liquids-RFM-401nivo-switch-vibrating-fork-level-switch-houston_e6145bb3-7461-4b9b-80d5-8926850ff3bf.png?v=1763386408"},{"product_id":"classic-810-threaded-thermal-flow-sensor","title":"CLASSIC 810 Threaded Thermal Flow Sensor","description":"The Kayden CLASSIC 810 thermal flow, level, and interface switch and transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, it is available in a wide range of thread sizes and insertion lengths. All models also feature a rugged flameproof enclosure with blind or lens cover options. The CLASSIC 810, from \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e, has advanced digital electronics that will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA Analog Output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 810 Thermal Flow Meter, Level Switch, Interface Measurement\u003c\/h3\u003e \u003ch5 style=\"text-align: left;\"\u003eProcess Connections - MNPT\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1\/2 inches\u003c\/li\u003e \u003cli\u003e3\/4 inches\u003c\/li\u003e \u003cli\u003e1.0 inches\u003c\/li\u003e \u003cli\u003e1 1\/4 inches\u003c\/li\u003e \u003cli\u003e1 1\/2 inches\u003c\/li\u003e \u003cli\u003e2 inches\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e1.2 inches (3.0 cm)\u003c\/li\u003e \u003cli\u003e2 inches (5.0 cm)\u003c\/li\u003e \u003cli\u003e3 inches (7.5 cm)\u003c\/li\u003e \u003cli\u003e4 inches (10.1 cm)\u003c\/li\u003e \u003cli\u003e6 inches (15.2 cm)\u003c\/li\u003e \u003cli\u003e9 inches (22.8 cm)\u003c\/li\u003e \u003cli\u003e12 inches (30.4 cm)\u003c\/li\u003e \u003cli\u003e18 inches (45.7 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available from 2.5 inches (6.0 cm) to 120 inches (305 cm) by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 810\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 Vdc\u003c\/li\u003e \u003cli\u003e120-240 Vac\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eCSA \u0026amp; FM: 3480 psi, 24000 kPa, 240 bar\u003c\/li\u003e \u003cli\u003eCRN (316\/316L Stainless Steel) - Canadian Registration\u003c\/li\u003e \u003cli\u003eNumber 0F22124.2C: 1990 psi, 13721 kPa, 137.2 bar\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/what-is-a-nema-rating-for-industrial-instrumentation\/\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Titanium\"\u003etitanium\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#Hastelloy\"\u003eHastelloy C-276\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for Kayden CLASSIC 810 Thermal Flow, Level, Interface\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eASME BPVC Sec. VIII Div. 1\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\/\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP55 \/ IP67 rating\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003ehigh pressure thermal flow meter\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eThermal Flow Meter\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel Switch and Detection\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface Measurement\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421454979,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-810-Threaded-Flow-Meter-Level-Switch-Interface-Temperature-Thermal-Sensor-Process-Solutions-Corp.png?v=1763386416"},{"product_id":"classic-812-flow-level-switch-flanged","title":"CLASSIC 812 Flow, Level Switch (Flanged)","description":"The CLASSIC 812 Flow, Level Switch and Transmitter features a precision welded, highly accurate stainless steel sensor. It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the CLASSIC 812 is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings, and insertion lengths. All \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the CLASSIC 812 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eper flange rating, ASME B16.5\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-50 to 392ËF (-45 to 200ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind cover or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eother materials available\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the CLASSIC 812\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003erated: \u003cul\u003e \u003cli\u003e120 Vac max\u003c\/li\u003e \u003cli\u003e30 Vdc max\u003c\/li\u003e \u003cli\u003e4A max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eCRN\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, level switch \u0026amp; interface\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 812 Flow, Level Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421487747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-812-Flanged-Switch-and-Transmitter-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-PSC-Texas.png?v=1763386417"},{"product_id":"classic-814-flanged-retractable-packing-gland","title":"CLASSIC 814, Flanged Retractable Packing Gland","description":"The CLASSIC 814 Flow, Level, and Interface Switch and Transmitter features a precision welded, highly accurate stainless steel sensor.Â It's ideal for liquids, gases, and slurries in clean or dirty processes. In addition, the \u003ca href=\"https:\/\/psctexas.com\/brand\/kayden-instruments\/\"\u003eKayden\u003c\/a\u003e CLASSIC 814 Retractable Packing Gland is available with a Raised Face or RTJ Flange, in a wide range of flange sizes and ANSI ratings, with low and medium pressure applications. All Kayden models also feature a rugged flameproof enclosure with blind or lens cover options. ItsÂ advanced digital electronics will revolutionize the way you monitor and control your process. \u003cul\u003e \u003cli\u003eeasy setup; no jumpers or trim pots\u003c\/li\u003e \u003cli\u003econtinuous self-test diagnostics with fault indicator\u003c\/li\u003e \u003cli\u003etemperature compensation\u003c\/li\u003e \u003cli\u003euniversal power 12-24 VDC and 115-230Â VAC standard\u003c\/li\u003e \u003cli\u003etwo SPDT relays - independently adjustable\u003c\/li\u003e \u003cli\u003e4-20 mA analog output\u003c\/li\u003e \u003cli\u003esmart heater function for power economy andÂ increased heater life\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003c\/ul\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23827 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas.jpg\" alt=\"Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-measurement-interface-sensing-process-solutions-texas\" width=\"1000\" height=\"380\"\u003e\u003c\/a\u003e \u003ch3 style=\"text-align: left;\"\u003eSpecifications of the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h3\u003e \u003ch5\u003eProcess Connections\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eretractable packing gland\u003c\/li\u003e \u003cli\u003eraised face\u003c\/li\u003e \u003cli\u003eRTJ flange\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eAdjustable Set Point Range\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e0 to 254 feet\/second (0 to 77 meters\/second)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eInsertion 'U' Lengths\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eminimum 2.5 inches (6.0 cm) to maximum 120 inches (305 cm)\u003c\/li\u003e \u003cli\u003ecustom lengths available by 1\/2\" (1 cm) increments\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eInput \/ Supply Power for the Kayden CLASSIC 814 Switch and Transmitter\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e12-24 VDC\u003c\/li\u003e \u003cli\u003e115-230 VAC\u003c\/li\u003e \u003cli\u003e50-60 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eOperating Pressure (Maximum)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003edependent on flange rating\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eTemperature Range (Sensor)\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e-40 to 320ËF (-40 to 160ËC)\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eLocal Enclosure\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof aluminum\u003c\/li\u003e \u003cli\u003e1\" FNPT conduit connection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConduit Connection Cover\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eflameproof: blind c0ver or glass lens\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eWetted Materials\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/#316L\"\u003e316\/316L stainless steel\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5 style=\"text-align: left;\"\u003eOutputs and Communications for the Kayden CLASSIC 814 Flanged, Retractable Packing Gland\u003c\/h5\u003e \u003cul\u003e \u003cli\u003etwo independent relays (SPDT)\u003c\/li\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/modbus.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eModbus\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eDisplay Panel Indicators\u003c\/h5\u003e \u003cul\u003e \u003cli\u003erelay 1 and 2\u003c\/li\u003e \u003cli\u003eset point 1 and 2\u003c\/li\u003e \u003cli\u003efault alarm\u003c\/li\u003e \u003cli\u003erun mode\u003c\/li\u003e \u003cli\u003estart-up bypass timer (for pump control)\u003c\/li\u003e \u003cli\u003eLED bar graph for flow rate, level, or interface indication\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eConfiguration Mode Features\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eadjustable sensitivity\u003c\/li\u003e \u003cli\u003ezero and span adjustment\u003c\/li\u003e \u003cli\u003eModbus addressable\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eApprovals\u003c\/h5\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.fmglobal.com\/research-and-resources\/standards-and-certification\/fm-approvals\" target=\"_blank\" rel=\"nofollow noopener\"\u003eFM\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eSingle Seal\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.ampp.org\/blogs\/webmasternaceorg\/2020\/03\/06\/nace-sspc-faqs\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNACE\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.nema.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eNEMA 4X\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\n\u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\"\u003e\u003cimg class=\"alignright wp-image-23806 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/09\/Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-Temperature-Pipeline-PSC-Texas.jpg\" alt=\"Kayden-CLASSIC-810-Rugged-Thermal-Sensor-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Pipeline-PSC-Texas\" width=\"1000\" height=\"534\"\u003e\u003c\/a\u003eApplications\u003c\/h3\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eFlow\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003epump protection - dry alarm\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/application-about-leak-detection-with-our-kayden-switch\/\"\u003eleak detection\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/flow\/\"\u003eflow monitoring and verification\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etank overflow protection\u003c\/li\u003e \u003cli\u003eflare gas monitoring\u003c\/li\u003e \u003cli\u003emonitoring purge air flow\u003c\/li\u003e \u003cli\u003elube oil systems\u003c\/li\u003e \u003cli\u003event monitoring\u003c\/li\u003e \u003cli\u003enatural gas to boilers\u003c\/li\u003e \u003cli\u003eemergency eye wash and shower stations\u003c\/li\u003e \u003cli\u003edrain line flow\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003ehigh pressure flows\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003etanker loading and unloading\u003c\/li\u003e \u003cli\u003erelief valve and rupture disk flow monitoring\u003c\/li\u003e \u003cli\u003eremote indication of flow via analog and digital outputÂ communications\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product\/liquid-dosing-system\/\"\u003echemical injection \/ additive flow monitoring\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/level\/\"\u003eLevel\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003estorage tanks\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003eoil separators and treaters\u003c\/a\u003e - high, low, \u0026amp; interface level\u003c\/li\u003e \u003cli\u003esumps - all types of fluids ( water, oil, etc. )\u003c\/li\u003e \u003cli\u003efree water knock-out tanks - high, low, and interface level\u003c\/li\u003e \u003cli\u003eleak detection (accumulation reservoir)\u003c\/li\u003e \u003cli\u003etank overflow\u003c\/li\u003e \u003cli\u003esampler systems\u003c\/li\u003e \u003cli\u003esand separators\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e\u003ca href=\"https:\/\/psctexas.com\/product-category\/interface\/\"\u003eInterface\u003c\/a\u003e\u003c\/h5\u003e \u003cul\u003e \u003cli\u003econtrol in separation vessels\u003c\/li\u003e \u003cli\u003edetection\u003c\/li\u003e \u003cli\u003econtrol and level detection in settling vessels\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003eMedia\u003c\/h5\u003e \u003cul\u003e \u003cli\u003eliquids, air, and gases\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area\u003c\/a\u003e and general-purpose areas\u003c\/li\u003e \u003cli\u003eslurries\u003c\/li\u003e \u003cli\u003ecorrosive liquids\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"text-align: left;\"\u003eProcess Conditions for the CLASSIC 814 Flow, Level, and Interface Switch and Transmitter\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eFlow\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003erecommended minimum of 5 pipe diameters from any disturbance\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003cli\u003eclean and dry\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003esufficient straight run flow profile (minimizes turbulence)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir \u0026amp; Gas\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ewet or saturated air \/ gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition and temperature\u003c\/li\u003e \u003cli\u003einsufficient straight run\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003eaerated fluids\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eLevel\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003cli\u003enon-turbulent\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquids\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSlurries\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition\u003c\/li\u003e \u003cli\u003eturbulence\u003c\/li\u003e \u003cli\u003elarge temperature swings\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\" colspan=\"2\"\u003eInterface\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eIdeal Process Conditions\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eUndesirable Process Conditions\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli\u003enon-turbulent applications\u003c\/li\u003e \u003cli\u003edry gas\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003econsistent process composition and temperature\u003c\/li\u003e \u003cli style=\"text-align: left;\"\u003elarge differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eLiquid to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eAir or Gas to Liquid\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eEmulsion\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003einconsistent process composition or temperature\u003c\/li\u003e \u003cli\u003ehigh aeration\u003c\/li\u003e \u003cli\u003ehigh turbulence\u003c\/li\u003e \u003cli\u003esmall differential in thermal conductivities\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSolids\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003edry, granulated processes are NOT good candidates for thermal switches\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Kayden Instruments","offers":[{"title":"Default Title","offer_id":45878421520515,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-switch-interface-sensing-process-solutions-texas.png?v=1763386418"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/collections\/KROHNE-WATERFLUX-3070-Magnetic-Flow-Meter-Municipal-Waste-Water-Flow-Measurement-MagMeter-Process-Solutions-Corp-PSC-Texas.jpg?v=1771534863","url":"https:\/\/www.psctexas.shop\/collections\/municipal-instrumentation.oembed?page=3","provider":"Process Solutions Corp.","version":"1.0","type":"link"}