{"title":"Signal Converters","description":"","products":[{"product_id":"pr-9113b-ex-ma-temperature-converter","title":"PR 9113B Ex mA Temperature Converter","description":"\u003cp\u003eThe PR 9113B Ex mA Temperature Converter is a high-precision temperature to current \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e for demanding industrial and process-automation environments. The 9113B is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113B, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interface\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eThe 9113B is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113B Ex mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113B Ex mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113B includes 2.6 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113B Ex mA Temperature Converter has certification for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113B correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113B is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113B Ex mA Temperature Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113B can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408025\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878365257859,"sku":"9113B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-B-Ex-mA-Temperature-Converter-PR-electronics-isolated-temperature-transmitter-intrinsically-safe-SIL-temp-sensor-for-RTD-thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408686"},{"product_id":"pr-3101-tc-temperature-converter","title":"PR 3101 TC Temperature Converter","description":"\u003cp\u003eThe PR 3101 TC Converter is a high-precision temperature signal converter for industrial automation, process control, and monitoring systems. This DIN-rail mountable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e module, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/tc-converter-3101\/\" title=\"PR electronics 3101 TC Temperature Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, measures thermocouple (TC) Type J and K sensors and outputs a conditioned analog current or voltage signal compatible with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and \u003ca title=\"Data Logging and Acquisition\" href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\"\u003edata acquisition\u003c\/a\u003e systems, providing accurate \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\" title=\"Temperature Converters\"\u003etemperature conversion\u003c\/a\u003e with excellent EMC performance and robust noise suppression.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature converter which measures standard TC J and K temperature sensors and provides an analog current or voltage output signal.\u003c\/li\u003e\n\u003cli\u003eAll terminals are over-voltage protected, polarity protected and short-circuit protected.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in Safe area or in Zone 2 \/ Division 2 \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003ePR 3101 TC Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith impressive flexibility, the 3101 features selectable fast (\u0026lt;30 ms) or damped (300 ms) response times to suit dynamic measurement or filtered applications. Furthermore, its pre-calibrated temperature ranges are easily selectable using intuitive DIP switches, with no external tools necessary. With accuracy better than 0.1 % of span, a signal-to-noise ratio over 60 dB, and compliance with \u003ca rel=\"noopener\" title=\"NAMUR Assocation\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 standards, the PR 3101 TC temperature converter delivers reliable, repeatable results in electrically noisy environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.1% of span.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is needed.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation, status of the input sensor and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe slim 6.1 mm housing allows high-density mounting on standard DIN rail (up to 163 units per meter), optimizing space in control cabinets and panels. Flexible 24 VDC (±30 %) power via connectors and comprehensive terminal protection against over-voltage, polarity reversal, and short-circuits ensure dependable operation. A front-panel LED clearly indicates normal operation and sensor status. With a rating for wide ambient temperatures \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C), and approval for safe Zone 2 \/ Division 2, and marine environments, the PR3101 TC temperature converter is an ideal choice for precision thermocouple signal conditioning in demanding installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3101-TC-temperature-converter-pr-electronics-signal-conditioning-process-solutions-corp-psc-texas.jpg?v=1768509414\" alt=\"PR-3101-TC-temperature-converter-pr-electronics-signal-conditioning-process-solutions-corp-psc-texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367486083,"sku":"3101","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3101-TC-temperature-converter-pr-electronics-psc-texas.png?v=1768509402"},{"product_id":"pr-3102-pt100-temperature-converter","title":"PR 3102 Pt100 Temperature Converter","description":"\u003cp\u003eThe PR 3102 Pt100 temperature converter is a high-performance \u003ca title=\"Temperature Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature signal conditioner\u003c\/a\u003e engineered for precision and reliability in industrial environments. It accurately measures standard 2-, 3-, or 4-wire Pt100 RTD sensors and converts the temperature resistance into a clean, proportional analog current or voltage output for process control, monitoring, or automation systems. With conversion accuracy better than 0.1 % of span, the 3102 delivers dependable measurement fidelity you can trust.\u003c\/p\u003e\n\u003cp\u003eThe 3102 temperature converter, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/pt100-converter-3102\/\" title=\"PR electronics 3102 Pt100 Temperature Converter\" rel=\"noopener\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides an analog voltage or current output. This Pt100 \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\" title=\"Temperature Converters\"\u003etemperature converter\u003c\/a\u003e can mount in the safe area or in Zone 2 \/ Division 2 \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e. Furthermore, it features approval for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature converter which measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides an analog current or voltage output signal.\u003c\/li\u003e\n\u003cli\u003eAll terminals offer protection from over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe 3102 Pt100 temperature converter can mount in Safe area or in Zone 2 \/ Division 2 areas and features approval for marine applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3102 Pt100 Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing a slim 6.1 mm DIN-rail mount housing, the PR 3102 Pt100 temperature converter maximizes cabinet space, allowing up to 163 converters per meter. Its flexible response time can be selected between a fast \u0026lt; 30 ms mode with sensor error detection and a damped 300 ms mode for noise-sensitive applications. Excellent EMC performance and 50\/60 Hz noise suppression meet \u003ca title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\/index.html\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, ensuring stable readings even in electrically harsh environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDurable protection includes over-voltage, reverse polarity, and short-circuit safeguarded terminals. A front green LED indicates normal operation and sensor status. The converter is suitable for safe area, Zone 2\/Division 2, and marine installations. Simple DIP-switch configuration offers access to over 1,000 pre-calibrated temperature ranges, making setup quick and intuitive.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.1% of span.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation, status of the input sensor and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMounting, Installation, and Programming\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/3102-pt100-temperature-converter-pr-electronics-compact-panel-module-process-solutions-psc-texas.jpg?v=1768511685\" alt=\"3102-pt100-temperature-converter-pr-electronics-compact-panel-module-process-solutions-psc-texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367518851,"sku":"3102","price":144.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3102-Pt100-Temperature-Converter-PR-electronics-signal-conditioning-module-process-solutions-corp-texas.jpg?v=1768511671"},{"product_id":"pr-3111-isolated-temperature-converter-for-thermocouples","title":"PR 3111 Isolated Temperature Converter for Thermocouples","description":"\u003cp\u003eThe PR 3111 Isolated Temperature Converter for Thermocouples is a precision temperature \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Device\"\u003esignal conditioning\u003c\/a\u003e module that converts standard thermocouple (TC) inputs into \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, high-integrity analog voltage or current outputs. Ideal for industrial automation, process control, and SCADA systems, this compact DIN-rail mountable module delivers exceptional measurement performance while protecting \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003econtrol equipment\u003c\/a\u003e from noise, transients, and ground loop interference. The 3111, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/tc-converter-isolated-3111\/\" title=\"PR electronics 3111 Isolated Temperature Converter for Thermocouples\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports common thermocouple types J and K with high accuracy, better than 0.05 % of span, across a wide range of calibrated temperature ranges selectable via DIP-switches.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExcellent accuracy, better than 0.05% of span\u003c\/li\u003e\n\u003cli\u003eSlimline housing of 6 mm\u003c\/li\u003e\n\u003cli\u003eExcellent EMC performance and 50\/60 Hz noise suppression\u003c\/li\u003e\n\u003cli\u003eSelectable \u0026lt; 30 ms \/ 300 ms response time\u003c\/li\u003e\n\u003cli\u003ePre-calibrated temperature ranges are selectable via DIP-switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3111 Isolated Temperature Converter for Thermocouples from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 3111 temperature converter features three-port galvanic isolation up to 2.5 kVAC, robust surge suppression, and excellent EMC immunity that meets \u003ca title=\"NAMUR Assocation\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations. Thus, it ensures stable, noise-free data even in electrically harsh installations. A selectable fast response time (\u0026lt;30 ms) or damped mode (300 ms) provides flexibility for both dynamic and smooth measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3111 temperature converter measures standard thermocouple J and K temperature sensors and provides an isolated analog voltage or current output.\u003c\/li\u003e\n\u003cli\u003eHigh 3 port isolation provides surge suppression and protects the control system from transients and noise.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is needed.\u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMeeting the NAMUR NE21 recommendations, the 3111 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3111 Isolated TC Temperature Converter\u003c\/h2\u003e\n\u003cp\u003eThe slim 6.1 mm housing allows high-density DIN-rail mounting, up to 163 units per meter, while a visible green LED indicates unit and sensor status at a glance. Flexible 24 VDC power options and comprehensive terminal protection against over-voltage and polarity errors make the PR3111 isolated temperature converter for thermocouples reliable and easy to install. With approval for safe areas as well as Zone 2\/Division 2 \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e and \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e, it’s a dependable choice for precision temperature measurement in industrial systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowered by 24 VDC (±30%) via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eA visible green LED indicates the operational status of the unit and the input sensor.\u003c\/li\u003e\n\u003cli\u003eAll terminals are protected against overvoltage and polarity error.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eThe 3111 can mount in the safe area or in Zone 2 \/ Division 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for marine applications.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMounting, Installation, and Programming\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3111-isolated-temperature-converter-for-thermocouples-TC-signal-isolation-pr-electronics-isolator-process-solutions-corp-psc-texas.jpg?v=1768581380\" alt=\"PR-3111-isolated-temperature-converter-for-thermocouples-TC-signal-isolation-pr-electronics-isolator-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3111: Supply via Power Rail Connector \/ Terminals","offer_id":46363001782403,"sku":"3111","price":204.0,"currency_code":"USD","in_stock":true},{"title":"3111-N: Supply via Terminals","offer_id":46363001815171,"sku":"3111-N","price":204.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3111-Isolated-Temperature-Converter-for-Thermocouples-TC-Isolator-pr-electronics-process-solutions-corp-texas.jpg?v=1768581402"},{"product_id":"pr-3112-pt100-temperature-converter","title":"PR 3112 Isolated Pt100 Temperature Converter","description":"\u003cp\u003eThe PR 3112 Isolated Pt100 Temperature Converter is a precision temperature \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Device\"\u003esignal conditioning\u003c\/a\u003e module. It converts resistance-based Pt100 RTD inputs into high-integrity \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e analog voltage or current outputs for industrial automation and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e systems. Designed for reliable operation in demanding environments, this slim DIN-rail-mounted module, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/pt100-converter-isolated-3112\/\" title=\"PR electronics 3112 Isolated Pt100 Temperature Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers excellent accuracy, better than 0.05 % of span, across a wide range of factory-calibrated temperature intervals selectable via DIP-switches.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSlimline housing of 6.1 mm\u003c\/li\u003e\n\u003cli\u003eExcellent EMC performance and 50\/60 Hz noise suppression\u003c\/li\u003e\n\u003cli\u003eSelectable \u0026lt; 30 ms \/ 300 ms response time\u003c\/li\u003e\n\u003cli\u003ePre-calibrated temperature ranges selectable via DIP-switches\u003c\/li\u003e\n\u003cli\u003eExcellent accuracy, better than 0.05% of span\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3112 Isolated Pt100 Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe 3112 isolated Pt100 temperature converter supports 2-, 3-, or 4-wire Pt100 sensors, thus providing a true representation of the measured temperature. Furthermore, it eliminates ground loops and protects control systems from noise, transients, and surges through high three-port galvanic isolation up to 2.5 kVAC. Its selectable fast (\u0026lt;30 ms) or damped (300 ms) response times offer flexibility for both dynamic and stable measurement requirements. In addition, a green front LED clearly indicates operational and sensor status.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 3112 isolated Pt100 temperature converter measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides an isolated analog voltage or current output.\u003c\/li\u003e\n\u003cli\u003eHigh 3 port isolation provides surge suppression and protects the control system from transients and noise.\u003c\/li\u003e\n\u003cli\u003eA visible green LED indicates the operational status of the unit and the input sensor.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eIsolated Signal Converter for Pt100 RTD Inputs\u003c\/h2\u003e\n\u003cp\u003eCompact yet robust, the 6.1 mm housing of the 3112 allows high-density installation, up to 163 units per meter of DIN rail. Furthermore, it is suitable for safe areas as well as Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous area\u003c\/a\u003e installations, including \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e. All terminals include over-voltage and polarity protection, and compliance with \u003cmeta charset=\"utf-8\"\u003e\u003ca rel=\"noopener\" title=\"NAMUR Assocation\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 standards ensures dependable performance even in harsh electromagnetic environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly powered by 24 VDC (±30%) via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the \u003cmeta charset=\"utf-8\"\u003e3112 isolated Pt100 temperature converter provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll terminals are protected against overvoltage and polarity error.\u003c\/li\u003e\n\u003cli\u003eThe 3112 can mount in the safe area or in Zone 2 \/ Division 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for marine applications.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eMounting, Installation, and Programming\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3112-Isolated-Pt100-Temperature-Converter-pr-electronics-rtd-signal-converter-analog-voltage-currrent-process-solutions-corp-psc-texas.jpg?v=1768584078\" alt=\"PR-3112-Isolated-Pt100-Temperature-Converter-pr-electronics-rtd-signal-converter-analog-voltage-currrent-process-solutions-corp-psc-texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3112: Supply via Power Rail Connector \/ Terminals","offer_id":46363053228163,"sku":"3112","price":189.0,"currency_code":"USD","in_stock":true},{"title":"3112-N: Supply via Terminals","offer_id":46363053260931,"sku":"3112-N","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3112-Isolated-Pt100-Temperature-Converter-pr-electronics-rtd-signal-converter-analog-voltage-current-outputs-processs-solutions-texas.jpg?v=1768584097"},{"product_id":"pr-3113-hart-temperature-converter","title":"PR 3113 HART Temperature Converter","description":"\u003cp\u003ePR Electronics 3113 HART Temperature Converter is a high-performance, \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e temperature conversion module designed for demanding industrial measurement environments. This compact yet powerful HART \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e accurately transforms signals from standard Pt100 RTDs and J\/K thermocouples into isolated analog current and \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 digital outputs, making the 3113, from \u003ca title=\"PR electronics 3113 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/hart-temperature-converter-3113\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ideal for integration with modern control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3113 HART temperature converter measures a standard Pt100, TC J and K temperature sensor and provides an isolated active analog current and HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 3 port isolation provides surge suppression and protects the control system from transients and noise.\u003c\/li\u003e\n\u003cli\u003eThe 3113 can mount in the safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003ePR 3113 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt with exceptional precision, better than 0.05 % of span, the 3113 ensures reliable, repeatable temperature measurement critical to process control, quality assurance, and safety systems. Its selectable internal or external cold junction compensation and switchable response time (from a rapid 60 ms up to 60 s) provide flexibility across diverse applications.\u003c\/p\u003e\n\u003cp\u003eEngineered with a slimline 6.1 mm housing, this HART temperature converter maximizes space efficiency on DIN rails, thus allowing up to 163 units per meter without gaps. Rugged galvanic isolation and robust EMC performance safeguard your system from electrical noise and transient surges, while compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 standards supports stable operation even in harsh industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly powered by 24 VDC (±30%) via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eA 60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 3113 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eA visible green LED indicates operational status of the unit and the input sensor.\u003c\/li\u003e\n\u003cli\u003eAll terminals are protected against overvoltage and polarity error. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eInstallation and configuration are effortless with DIP-switch settings for over 1,000 factory-calibrated temperature ranges and selectable HART modes, thus offering full read-write access for advanced device setup. Suitable for safe areas as well as Zone 2 \/ Div. 2 hazardous locations, the PR electronics 3113 delivers precision, flexibility, and reliability in a compact, industrial-grade package.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units to mount per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas.jpg?v=1768842513\" alt=\"PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3113: Supply via Power Rail Connector \/ Terminals","offer_id":46379828576387,"sku":"3113","price":304.0,"currency_code":"USD","in_stock":true},{"title":"3113-N: Supply via Terminals","offer_id":46379828609155,"sku":"3113-N","price":304.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-rtd-pt100-temp-signal-converter-process-solutions-corp-texas.jpg?v=1768842546"},{"product_id":"pr-3331-loop-powered-temperature-converter","title":"PR 3331 Loop-Powered Temperature Converter","description":"\u003cp\u003eThe PR 3331 Loop-Powered Isolated Temperature Converter is a precision \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for converting industrial temperature sensor inputs into reliable \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e 4–20 mA current loop outputs. Ideal for process automation, control systems, and industrial instrumentation, the 3331, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/temperature-converter-loop-powered-isolated-3331\/\" title=\"PR electronics 3331 Loop-Powered Temperature Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports standard temperature sensors including Pt100 RTDs and thermocouples (TC J \u0026amp; K). Its loop-powered design eliminates the need for external power, thus simplifying installation and reducing infrastructure costs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3331 is a loop-powered \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e that measures a standard Pt100, thermocouple (TC) J and K temperature sensor, and provides an isolated passive analog current output signal.\u003c\/li\u003e\n\u003cli\u003eHigh 2 port isolation provides surge suppression and protects the \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003econtrol system\u003c\/a\u003e from transients and noise.\u003c\/li\u003e\n\u003cli\u003eThe 3331 can mount in the safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3331 Loop-Powered Temperature Converter\u003c\/h2\u003e\n\u003cp\u003eFeaturing excellent conversion accuracy better than 0.05 % of span and selectable fast response times as low as \u0026lt;30 ms, the PR 3331 Loop-Powered Temperature Converter ensures accurate, real-time temperature data for critical process monitoring. Robust galvanic isolation (2.5 kVAC) and compliance with \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21\/NE43 standards deliver superior noise suppression and sensor error handling, even in harsh electrical environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop powered by 5.5 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary. \u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 3331 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThis loop-powered temperature converter meets the NAMUR NE43 standard defining out of range in addition to sensor error output values.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection against overvoltage as well as polarity error.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe slim 6.1 mm DIN-rail housing enables high-density mounting in control panels, supporting up to 163 units per meter without gaps. Easy configuration via DIP switches provides access to more than 1000 factory-calibrated temperature ranges. Furthermore, selectable internal or external cold junction compensation enhances flexibility for thermocouple applications.\u003c\/p\u003e\n\u003cp\u003eBuilt for industrial reliability, the PR 3331 operates across a wide temperature range \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C) and offers certification for Safe Areas as well as Zone 2\/Division 2 and marine applications. Thus the 3331 loop-powered temperature converter is a versatile choice for industrial temperature measurement and process control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units to be mounted per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-3331-loop-powered-temperature-converter-pr-electronics-signal-conditioning-temp-converter-process-solutions-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3331-loop-powered-temperature-converter-pr-electronics-signal-conditioning-temp-converter-process-solutions-psc-texas.jpg?v=1768933534\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367649923,"sku":"3331","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3331-loop-powered-temperature-converter-pr-electronics-signal-converter-thermocouple-pt100-rtd-process-solutions-corp-psc-texas.jpg?v=1768933966"},{"product_id":"pr-3333-pt100-temperature-converter","title":"PR 3333 Pt100 Temperature Converter","description":"\u003cp\u003eThe PR 3333 Pt100 Temperature Converter is a compact and reliable temperature \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioner\u003c\/a\u003e for converting standard Pt100 RTD temperature sensor readings into a passive analog current signal for industrial process control and automation systems. Ideal for harsh environments, this loop-powered Pt100 \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e supports 2-, 3-, or 4-wire RTD configurations. Furthermore, the 3333, from \u003ca title=\"PR electronics 3333 Pt100 Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/pt100-converter-loop-powered-3333\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers excellent conversion performance with accuracy better than 0.1 % of span and a high signal-to-noise ratio (\u0026gt; 60 dB).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3333 is a Pt100 temperature converter which measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and also provides a passive analog current output signal.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection against over-voltage, polarity, and short-circuit. \u003c\/li\u003e\n\u003cli\u003eThe device can mount in safe areas or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and also features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3333 Pt100 Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing selectable fast (\u0026lt; 30 ms) or damped (300 ms) response times, the PR 3333 Pt100 Temperature Converter ensures both rapid reaction to temperature changes and noise-free outputs when necessary. Its versatile loop-powered design (3.3–35 VDC) eliminates the need for an external power supply, thus simplifying installation and reducing wiring complexity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop-powered by 3.3 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.1% of span.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe PR 3333 meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for industrial and hazardous installations, the PR 3333 meets NAMUR NE21 and NE43 standards for superior EMC immunity and sensor error handling. Furthermore, it features certification for Safe Areas as well as Zone 2\/Division 2 and marine applications. The slim 6.1 mm DIN-rail housing allows high-density mounting, up to 163 units per meter, thus maximizing panel space efficiency.\u003c\/p\u003e\n\u003cp\u003eThe 3333 features easy DIP-switch configuration for over 1,000 factory-calibrated temperature ranges and robust terminal protection against over-voltage, polarity reversal, and short circuits. Thus, the PR 3333 delivers dependable, high-performance Pt100 temperature conversion for water\/wastewater, chemical, energy, and manufacturing applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3333-Pt100-temperature-converter-pr-electronics-temp-converter-signal-conditioning-process-solutions-corp-psc-texas.jpg?v=1768940370\" alt=\"PR-3333-Pt100-temperature-converter-pr-electronics-temp-converter-signal-conditioning-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367682691,"sku":"3333","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3333-Pt100-Temperature-Converter-PR-electronics-signal-converter-temp-process-solutions-corp-texas.jpg?v=1768940387"},{"product_id":"pr-3337-hart-temperature-converter","title":"PR 3337 HART Temperature Converter","description":"\u003cp\u003eThe PR 3337 HART Temperature Converter is a high-performance \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e ideal for industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e, automation, and instrumentation systems where accurate temperature measurement and digital communication are essential. This \u003ca title=\"HART Protocol\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e-compatible temperature converter accepts standard Pt100 RTD and thermocouple (TC J \u0026amp; K) sensor inputs. The 3337, from \u003ca title=\"PR electronics 3337 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/hart-temperature-converter-loop-powered-3337\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, then provides both an \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e analog 4–20 mA output and a digital HART 7 communication signal for advanced diagnostics and configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3337 HART temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated passive analog current as well as a HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 2-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection from over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in safe areas or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3337 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 3337 HART Temperature Converter delivers excellent conversion accuracy, better than 0.05 % of span, as well as selectable fast or damped response times (60 ms\/60 s). Thus, the 3337 is ideal for responsive feedback in industrial control loops. Its robust 2-port galvanic isolation (2.5 kVAC) eliminates ground loops, suppresses noise and transients, and protects sensitive PLC, DCS, and SCADA inputs.\u003c\/p\u003e\n\u003cp\u003eFeaturing more than 1,000 pre-calibrated temperature ranges and selectable internal\/external cold junction compensation, this loop-powered HART temperature converter offers flexible configuration with DIP switches or full HART read\/write capability. The slim 6.1 mm DIN-rail housing supports high-density panel mounting, thus saving space in control cabinets. Furthermore, rugged terminal protection guards against over-voltage, polarity reversal, and short circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop-powered by 6.2 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eSelectable internal \/ external CJC.\u003c\/li\u003e\n\u003cli\u003e60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe PR 3337 meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for safe areas and featuring certification for Zone 2 \/ Division 2 and marine applications, the 3337 ensures reliable performance across industrial, energy, wastewater, and chemical process environments. The 3337 delivers accurate temperature conversion with modern HART communication support.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas.jpg?v=1768941910\" alt=\"PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367715459,"sku":"3337","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-temperature-converter-pr-electronics-temp-conversion-signal-process-solutions-corp-psc-texas.jpg?v=1768941929"},{"product_id":"pr-5131-2-wire-temperature-transmitter","title":"PR 5131 2-wire Temperature Transmitter","description":"\u003cp\u003eThe PR 5131 2‑wire Programmable Transmitter is a versatile industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and reliable process control. Featuring universal inputs for RTD, thermocouple (TC), mV, linear resistance, current (mA), and voltage (V), the 5131 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers flexible integration across a wide range of sensing applications. This 2-wire temperature transmitter converts sensor inputs into a standardized 4-20 mA loop output, thus simplifying connection to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS systems, and analog input modules for streamlined industrial automation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5131 Series can configure with the software program PReset using a standard PC and the PR 5909 Loop Link communications unit.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5131A 2-wire Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5100\/2-wire-programmable-transmitter-5131a\/\" target=\"_blank\"\u003ePR 5131A\u003c\/a\u003e 2-wire Temperature Transmitter is suitable for Safe Areas.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5131B 2-wire Ex Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/2-wire-programmable-transmitter-5131b\/\" target=\"_blank\"\u003ePR 5131B\u003c\/a\u003e 2-wire Ex Temperature Transmitter is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5131 2-wire Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and safety, the PR 5131 2-wire Temperature Transmitter features 3.75 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e, protecting sensitive control equipment from electrical noise and interference. As a result, the 5131 also enhances system reliability. Its jumper-selectable inputs allow independent channel configuration for temperature or current \/ voltage measurement, thus providing customization for specific process requirements. The transmitter supports automatic cable compensation (3- or 4-wire) and programmable cable resistance for 2-wire setups.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent channel jumper selectable inputs for current \/ voltage or temperature. \u003c\/li\u003e\n\u003cli\u003eCurrent input programmable in range 0-100 mA and voltage inputs in range 0-250 VDC.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation.\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor error detection including \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration is easy using \u003ca title=\"PR electronics PReset Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset software\u003c\/a\u003e and the Loop Link communications interface, thus enabling precision tuning and rapid deployment across facilities. DIN-rail mounting ensures compact installation and efficient use of cabinet space. In addition, programmable sensor error detection, including NAMUR NE43 compliance, delivers improvements in safety and diagnostic feedback. Ideal for temperature monitoring, resistance signal conversion, and process measurement tasks, the PR 5131 2-wire Temperature Transmitter offers dependable performance for demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 2-channel version has full galvanic isolation between the channels.\u003c\/li\u003e\n\u003cli\u003eSeparation of circuits in PELV\/SELV installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas.jpg?v=1769552245\" alt=\"PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5131AA: 1-Channel (Universal Input)","offer_id":46423771054211,"sku":"5131AA","price":372.0,"currency_code":"USD","in_stock":true},{"title":"5131AB: 2-Channel (Universal Input)","offer_id":46423771086979,"sku":"5131AB","price":631.0,"currency_code":"USD","in_stock":true},{"title":"5131B1A: Ex version; 1-Channel - (RTD\/TC\/mV\/R Input)","offer_id":46423771119747,"sku":"5131B1A","price":450.0,"currency_code":"USD","in_stock":true},{"title":"5131B1B: Ex version; 2-Channel - (RTD\/TC\/mV\/R Input)","offer_id":46423771152515,"sku":"5131B1B","price":728.0,"currency_code":"USD","in_stock":true},{"title":"5131B2A: Ex version; 1-Channel - (mA\/V\/mV Input)","offer_id":46423771185283,"sku":"5131B2A","price":408.0,"currency_code":"USD","in_stock":true},{"title":"5131B2B: Ex version; 2-Channel - (mA\/V\/mV Input)","offer_id":46423771218051,"sku":"5131B2B","price":678.0,"currency_code":"USD","in_stock":true},{"title":"5131B3B: Ex version; Channel 1 - RTD\/TC\/mV\/R; Channel 2 - mA\/V\/mV","offer_id":46423771250819,"sku":"5131B3B","price":704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-pr5131-temperature-converter-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769552538"},{"product_id":"pr-9113-ma-temperature-converter","title":"PR 9113 mA Temperature Converter","description":"\u003cp\u003eThe PR 9113 mA Temperature Converter is a high-precision temperature to current \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e for demanding industrial and process-automation environments. The 9113 Series is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca title=\"PR electronics 4500 Series Programming Interface\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9113A mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/9100\/temperature-ma-converter-9113a\/\" target=\"_blank\"\u003ePR 9113A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver.\u003c\/li\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910, channel 1 \/ PR 5913, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9113B Ex mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" target=\"_blank\"\u003ePR 9113B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113 mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113 mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 Series includes 2.6 kVAC galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113 mA Temperature Converter has certification for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113 Series is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113 mA Temperature Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113 Series can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408025\" alt=\"PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel \/ None - Standard","offer_id":45878368698499,"sku":"9113AA","price":428.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501312131,"sku":"9113AA-U9","price":438.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel \/ None - Standard","offer_id":46499924476035,"sku":"9113AB","price":650.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501344899,"sku":"9113AB-U9","price":659.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel \/ None - Standard","offer_id":46499924574339,"sku":"9113BA","price":453.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501377667,"sku":"9113BA-U9","price":465.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel \/ None - Standard","offer_id":46499924607107,"sku":"9113BB","price":676.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501410435,"sku":"9113BB-U9","price":686.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Converter-PR-electronics-IS-hazardous-area-temperature-transmitter-intrinsic-safety-RTD-thermocouple-Process-Solutions-PSC-Texas.jpg?v=1770408686"},{"product_id":"pr-9113-emp-ma-temperature-converter-with-emphasis-assessment","title":"PR 9113-EMP mA Temperature Converter with EMPHASIS Assessment","description":"\u003cp\u003eThe PR 9113-EMP mA Temperature Converter is a high-precision temperature to current \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e with EMPHASIS assessment for the nuclear industry. The 9113-EMP is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113-EMP Series, from \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/9100\/temperature-ma-converter-9113a-emp\/\" title=\"PR electronics 9113A-EMP mA Temperature Converter with EMPHASIS Assessment\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interface\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\"\u003e\u003c\/a\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eFeatures EMPHASIS assessment and mounts in \u003cmeta charset=\"utf-8\"\u003eZone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113-EMP mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113-EMP mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 includes 2.6 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113-EMP Temperature \/ mA Converter has certification for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113-EMP is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113-EMP Temperature \/ mA Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113-EMP can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648896\" alt=\"PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel","offer_id":46575406710915,"sku":"9113AA-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel","offer_id":46575406743683,"sku":"9113AB-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel","offer_id":46575406776451,"sku":"9113BA-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel","offer_id":46575406809219,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-temperature-to-current-signal-converter-EMPHASIS-Assessment-Nuclear-Power-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648923"},{"product_id":"pr-9113b-emp-temperature-ma-converter","title":"PR 9113B-EMP Temperature \/ mA Converter with EMPHASIS Assessment","description":"\u003cp\u003eThe PR 9113B-EMP Temperature \/ mA Converter is a high-precision temperature to current \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e with EMPHASIS assessment for the nuclear industry. The 9113B-EMP is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113B-EMP, from \u003ca title=\"PR electronics 9113B-EMP Temperature \/ mA Converter with EMPHASIS Assessment\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca title=\"PR electronics 4500 Series Programming Interface\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"PR electronics 9113B Ex mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" target=\"_blank\"\u003e\u003c\/a\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eFeatures EMPHASIS assessment and mounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 includes 2.6 kVAC galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter has certification for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; margin-bottom: 16px; float: none;\" alt=\"PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648896\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"A: 1-Channel","offer_id":46575380627587,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"B: 2-Channel","offer_id":46575380660355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-B-EMP-Temperature-mA-Converter-PR-electronics-Signal-Converter-with-EMPHASIS-Assessment-for-Thermocouple-RTD-4-20-mA-Output-Process-Solutions-PSC-Texas.jpg?v=1770651975"},{"product_id":"pr-9116b-ex-universal-converter","title":"PR 9116B Ex Universal Converter","description":"\u003cp\u003eThe PR 9116B Ex Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for industrial process control and automation. The 9116B, from \u003ca title=\"PR electronics 9116B Ex Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eThe 9116B is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116B Ex Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116B features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116B Ex Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B Ex Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutio.jpg?v=1770654546\" alt=\"PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"1: Uo 28 VDC","offer_id":46575683928195,"sku":"9116B-1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2: Uo 21.4 VDC","offer_id":46575683960963,"sku":"9116B-2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-B-Ex-Universal-Converter-PR-electronics-9116B-temperature-voltage-resistance-signal-converter-universal-transmitter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770655699"},{"product_id":"pr-9116b-emp-ex-universal-converter-for-nuclear-industry","title":"PR 9116B-EMP Ex Universal Converter for Nuclear Industry","description":"\u003cp\u003eThe PR 9116B-EMP Ex Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device that's EMPHASIS assessed for nuclear applications. The 9116B-EMP, from \u003ca title=\"PR electronics 9116B-EMP Ex Universal Converter with EMPHASIS Assessment\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b-emp\/\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eThe 9116B-EMP is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116B-EMP Ex Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116B-EMP features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116B-EMP Ex Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B-EMP has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116B-EMP correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B-EMP Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; margin-bottom: 16px; float: none;\" alt=\"PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas.jpg?v=1770658616\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368927875,"sku":"9116B-EMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-B-Ex-Universal-Converter-PR-electronics-Intrinsically-Safe-Signal-Converter-for-Nuclear-Industry-EMPHASIS-Assessed-Hazardous-Area-Signal-Converter-Process-Solutions-Texas.jpg?v=1770659390"},{"product_id":"pr-5131b-2-wire-ex-programmable-transmitter","title":"PR 5131B 2-wire Ex Programmable Transmitter","description":"\u003cp\u003eThe PR 5131B 2‑wire Ex Programmable Transmitter is a versatile industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and reliable process control. Featuring universal inputs for RTD, thermocouple (TC), mV, linear resistance, current (mA), and voltage (V), the 5131B, from \u003ca rel=\"noopener\" title=\"PR electronics 5131B 2-wire Ex Programmable Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/2-wire-programmable-transmitter-5131b\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers flexible integration across a wide range of sensing applications. This 2-wire temperature transmitter converts sensor inputs into a standardized 4-20 mA loop output, thus simplifying connection to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS systems, and analog input modules for streamlined industrial automation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis transmitter can configure with \u003ca title=\"PR electronics PReset Programming Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset\u003c\/a\u003e programming software using a standard PC and the PR 5909 Loop Link communications unit.\u003c\/li\u003e\n\u003cli\u003eThe PR 5131B 2-wire Ex Temperature Transmitter is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5131B 2-wire Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and safety, the PR 5131B 2-wire Ex Temperature Transmitter features 3.75 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e, protecting sensitive control equipment from electrical noise and interference. As a result, the 5131B also enhances system reliability. Its jumper-selectable inputs allow independent channel configuration for temperature or current \/ voltage measurement, thus providing customization for specific process requirements. The transmitter supports automatic cable compensation (3- or 4-wire) and programmable cable resistance for 2-wire setups.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent channel jumper selectable inputs for current \/ voltage or temperature. \u003c\/li\u003e\n\u003cli\u003eCurrent input programmable in range 0-100 mA and voltage inputs in range 0-250 VDC.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation.\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor error detection including \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration is easy using PReset software and the Loop Link communications interface, thus enabling precision tuning and rapid deployment across facilities. DIN-rail mounting ensures compact installation and efficient use of cabinet space. In addition, programmable sensor error detection, including NAMUR NE43 compliance, delivers improvements in safety and diagnostic feedback. Ideal for temperature monitoring, resistance signal conversion, and process measurement tasks, the PR 5131B 2-wire Ex Temperature Transmitter offers dependable performance for demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 2-channel version has full galvanic isolation between the channels.\u003c\/li\u003e\n\u003cli\u003eSeparation of circuits in PELV\/SELV installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas.jpg?v=1769552245\" alt=\"PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369386627,"sku":"5131B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-B-2-wire-ex-temperature-transmitter-pr-electronics-intrinsically-safe-temperature-converter-process-solutions-psc-texas.jpg?v=1769552538"},{"product_id":"pr-5223a-programmable-fi-ff-converter","title":"PR 5223A Programmable f\/I-f\/f Converter","description":"\u003cp\u003eThe PR 5223A Programmable f\/I‑f\/f Converter is a high-performance, programmable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e for industrial automation and process control applications. Ideal for converting \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/frequency-and-pulse\" title=\"Frequency and Pulse Devices\"\u003efrequency\u003c\/a\u003e signals into precise analog current or voltage outputs, this versatile device supports both frequency-to-current (f\/I) and frequency-to-frequency (f\/f) functions. Thus, the 5223A, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/special-devices\/5200\/programmable-f-i-f-f-converter-5223a\/\" title=\"PR electronics 5223A Programmable f\/I-f\/f Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for pulse calculation, frequency scaling, division, multiplication, as well as buffering of fast pulse trains. Featuring universal power supply compatibility with 21.6-253 VAC or 19.2-300 VDC, the PR 5223A ensures flexible installation across a broad range of system configurations. Furthermore, its galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e (3.75 kVAC) protects sensitive inputs and outputs from electrical noise and interference, enhancing reliability in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5223A Programmable f\/I-f\/f Converter can configure with a standard PC and the Loop Link communications unit, or deliver with fully configuration.\u003c\/li\u003e\n\u003cli\u003eThe f\/I function performs frequency to current and voltage conversion.\u003c\/li\u003e\n\u003cli\u003eThe f\/f function, for pulse division or multiplication, can also act as a buffer for collecting fast pulse trains.\u003c\/li\u003e\n\u003cli\u003eUsers can enter a scale factor in all functions.\u003c\/li\u003e\n\u003cli\u003eUsing both digital inputs, pulse addition or subtraction are possible.\u003c\/li\u003e\n\u003cli\u003eThe frequency generator function is used as, for example, a time base or clock generator.\u003c\/li\u003e\n\u003cli\u003eInput and supply polarity reversal protection.\u003c\/li\u003e\n\u003cli\u003eCurrent and voltage output signals galvanically separate from the supply and the inputs.\u003c\/li\u003e\n\u003cli\u003eProgrammable digital outputs including NPN, PNP, or relay options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5223A Programmable f\/I-f\/f Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 5223A Programmable f\/I-f\/f Converter accommodates a wide variety of input sensors including \u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" title=\"NAMUR Association\" rel=\"noopener\"\u003eNAMUR\u003c\/a\u003e, tacho, NPN, PNP, TTL, S0, and contact signals over a 0-20,000 Hz range, with programmable analog outputs (0-20 mA or 0-10 V) for seamless integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003econtrol systems\u003c\/a\u003e. With programmable digital outputs (PNP, NPN, or optional relays) and built-in LED indicators for input\/output status and error detection, the 5223A enhances diagnostics and operational visibility. Configuration is easy via a standard PC and the PR Loop Link communications interface, or it can ship with preconfiguration for specific applications. This programmable f\/I-f\/f converter delivers dependable performance, flexibility, and precision, thus it's perfect for frequency conditioning in industrial automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.\u003c\/li\u003e\n\u003cli\u003eAnalog current output can be configured to any current within 0...20 mA range.\u003c\/li\u003e\n\u003cli\u003eVoltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.\u003c\/li\u003e\n\u003cli\u003eInput range:\n\u003cul\u003e\n\u003cli\u003eFrequency: 0...20,000 Hz\u003c\/li\u003e\n\u003cli\u003eSensor types: NAMUR, tacho, NPN, PNP, TTL, S0, contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput range:\n\u003cul\u003e\n\u003cli\u003eCurrent and voltage output: 0-20 mA \/ 0-10 V\u003c\/li\u003e\n\u003cli\u003eRelay outputs: 0-20 Hz\u003c\/li\u003e\n\u003cli\u003eNPN and PNP output as f\/f: 0-1000 Hz\u003c\/li\u003e\n\u003cli\u003eNPN and PNP output as generator: 0-20,000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5223A-Programmable-f-i-f-f-Converter-PR-electronics-programmable-frequency-converter-calculator-signal-pulse-conversion-process-solutions-psc-texas.jpg?v=1769701585\" alt=\"PR-5223A-Programmable-f-i-f-f-Converter-PR-electronics-programmable-frequency-converter-calculator-signal-pulse-conversion-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5223A1: 2 NPN\/PNP Outputs","offer_id":46445818871939,"sku":"5223A1","price":704.0,"currency_code":"USD","in_stock":true},{"title":"5223A2: 2 SPST Relay Outputs","offer_id":46445818904707,"sku":"5223A2","price":751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5223A-Programmable-f-i-f-f-Converter-PR-electroincs-frequency-converter-signal-pulse-conversion-current-voltage-converter-process-solutions-corp-psc-texas.jpg?v=1769702073"},{"product_id":"pr-4222-universal-if-converter","title":"PR 4222 Universal I\/f Converter","description":"\u003cp\u003eThe PR 4222 Universal I\/f Converter is a robust industrial \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e that transforms a wide range of analog sensor inputs into reliable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/frequency-and-pulse\" title=\"Frequency and Pulse Signal Devices\"\u003efrequency\u003c\/a\u003e outputs for process control, automation, and monitoring systems. It supports inputs from RTDs, thermocouples (TC), resistance (Ohm), potentiometers, as well as mA and voltage signals. Thus, the \u003cmeta charset=\"utf-8\"\u003e4222, from \u003ca rel=\"noopener\" title=\"PR electronics 4222 Universal I\/f Converter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4200\/universal-i-f-converter-4222\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is highly adaptable for linear measurement and signal processing applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable via detachable display front (\u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e series).\u003c\/li\u003e\n\u003cli\u003eFeatures process calibration, signal simulation, password protection, error diagnostics, and selection of help text in several languages.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a frequency signal, for example, from solenoids and butterfly \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003ePower supply and \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003esignal isolator\u003c\/a\u003e for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control by way of a frequency signal transmitted to, for example, a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC\u003c\/a\u003e or a process computer.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation and conversion of analog signals to frequency signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4222 Universal I\/f Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe PR 4222 Universal I\/f Converter has the capability to generate frequency outputs from 0 to 25,000 Hz in NPN, PNP, or TTL formats. Thus, the 4222 enables seamless integration with PLCs, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\" title=\"Data Logging and Acquisition\"\u003edata acquisition\u003c\/a\u003e systems, and process computers that rely on frequency-based signal processing. Its universal AC\/DC power supply range and compact design allow for flexible installation across diverse industrial environments. Continuous stored data checks and status indication via a front LED ensure operational reliability, while 3-port galvanic isolation (2.3 kVAC) delivers excellent noise immunity and signal integrity in harsh environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the 4222 is used in combination with the PR 4500 display \/ programming fronts, all operational parameters can adjust to suit any application. \u003c\/li\u003e\n\u003cli\u003eAs the PR 4222 features electronic hardware switches, it isn't necessary to open the device for setting of DIP switches.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e3-port 2.3 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe PR 4222 Universal I\/f Converter is compatible with a detachable PR 4500 series display for easy programming, process calibration, signal simulation and diagnostics without opening the unit, thus enhancing safety and convenience for technicians. Ideal for applications like \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e linearization, resistance-to-frequency conversion, and analog to frequency signal isolation, the PR 4222 is a versatile choice for industrial automation and control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM Approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous locations\u003c\/a\u003e: Nonincendive for Class I, Division 2, Groups A, B, C, and D Hazardous (Classified) Indoor Locations with a T5 temperature classification; and Nonincendive for Class I, Division 2, Group IIC Hazardous (Classified) Indoor Locations with a T5 temperature classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4222-universal-i-f-converter-pr-electronics-industrial-frequency-conversion-signal-transmitter-process-solutions-psc-texas.jpg?v=1769103344\" alt=\"PR-4222-universal-i-f-converter-pr-electronics-industrial-frequency-conversion-signal-transmitter-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369943683,"sku":"4222","price":498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4222-universal-i-f-converter-pr-electronics-frequency-converter-process-solutions-corp-psc-texas.jpg?v=1769103360"},{"product_id":"pr-9116-universal-converter","title":"PR 9116 Universal Converter","description":"\u003cp\u003eThe PR 9116 Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for industrial process control and automation. The 9116, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eModels in the 9116 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9116A Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/9100\/universal-converter-9116a\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eModel \u003ca title=\"PR electronics 9116B Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116 Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116 features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116 Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Series has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116 Series correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutio.jpg?v=1770654546\" alt=\"PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483617411,"sku":"9116A1","price":543.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483650179,"sku":"9116A1-U9","price":554.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483682947,"sku":"9116A2","price":550.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483715715,"sku":"9116A2-U9","price":557.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483748483,"sku":"9116B1","price":570.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483781251,"sku":"9116B1-U9","price":579.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483814019,"sku":"9116B2","price":577.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483846787,"sku":"9116B2-U9","price":583.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-Signal-Converter-Universal-Transmitter-Temperature-Voltage-Linear-Resistance-Process-Solutions-Texas.jpg?v=1770655699"},{"product_id":"pr-9116a-emp-universal-converter-emphasis-assessed","title":"PR 9116-EMP Universal Converter, EMPHASIS Assessed","description":"\u003cp\u003eThe PR 9116-EMP Universal Converter is a high-performance \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device that's EMPHASIS assessed for nuclear applications. The 9116-EMP, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eModels in the 9116-EMP are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/9100\/universal-converter-9116a-emp\/\" title=\"PR electronics 9116A-EMP Universal Converter\" target=\"_blank\"\u003ePR 9116A-EMP\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b-emp\/\" title=\"PR electronics 9116B-EMP Ex Universal Converter\" target=\"_blank\"\u003ePR 9116B-EMP\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116-EMP Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116-EMP features robust galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116-EMP Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116-EMP has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116-EMP correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116-EMP Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas.jpg?v=1770658616\" alt=\"PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9116A-EMP: Safe Area; Zone 2 \/ Class 1; Div 2; Groups A B C D \/ 1: Uo 28 VDC","offer_id":46575613575299,"sku":"9116A1-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116A-EMP: Safe Area; Zone 2 \/ Class 1; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC","offer_id":46575613608067,"sku":"9116A2-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116B-EMP: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC","offer_id":46575613640835,"sku":"9116B1-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116B-EMP: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC","offer_id":46575613673603,"sku":"9116B2-EMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR-9116A-EMP-Signal-Transmitter-EMPHASIS-Assessed-Nuclear-Power-Signal-Converter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770659390"},{"product_id":"pr-3104-isolated-converter","title":"PR 3104 Isolated Converter","description":"\u003cp\u003eThe PR 3104 Isolated Converter is a precision \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003esignal isolator\u003c\/a\u003e and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Conversion Devices\"\u003econverter\u003c\/a\u003e for enhancing the reliability and integrity of standard DC process signals in demanding industrial environments. It provides galvanic isolation and conversion of analog current and voltage signals, eliminating ground loops and protecting sensitive control systems from noise, transients, and common-mode interference. With a slim 6.1 mm DIN-rail housing, the 3104, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/isolated-converter-3104\/\" title=\"PR electronics 3104 Isolated Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, maximizes panel density and allows up to 163 units per meter, optimizing cabinet space without sacrificing performance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGalvanic separation of analog current and voltage signals.\u003c\/li\u003e\n\u003cli\u003eA competitive choice in terms of both price and technology for galvanic isolation of all signal types to SCADA systems or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC equipment\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eHigh 3-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals offer protection from over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in Safe area or in Zone 2 \/ Division 2 \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and is features approval for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3104 Isolated Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eDesigned for seamless integration, the 3104 offers factory-calibrated measurement ranges and simple DIP-switch configuration, making setup quick and intuitive. Its high 3-port isolation of up to 2.5 kVAC and excellent signal-to-noise ratio (\u0026gt; 60 dB) ensure clean, stable signals for PLCs, SCADA systems, and automation equipment. A fast response time (\u0026lt; 7 ms) and robust protection from over-voltage, polarity, and short-circuit safeguarded terminals further enhance reliability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt; 7 ms.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eInputs and outputs are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe converter supports loop power supply (\u0026gt; 17 V) for 2-wire transmitters and operates across a wide ambient temperature range \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C), making it suitable for industrial, \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine\u003c\/a\u003e, and hazardous area installations (Zone 2\/Division 2). A front green LED clearly indicates normal operation and fault status, ensuring easy diagnostics and peace of mind.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 25px; float: none;\" alt=\"PR-3104-isolated-converter-signal-isolator-galvanic-isolation-pr-electronics-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3101-isolated-repeater-galvanic-isolation-pr-electronics-prevent-noise-process-solutions-psc-texas_1f15e971-8296-445c-ba82-ef0e58713203.jpg?v=1768514963\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3104: Supply via Power Rail Connector \/ Terminals","offer_id":46359887970435,"sku":"3104","price":222.0,"currency_code":"USD","in_stock":true},{"title":"3104-N: Supply Terminals","offer_id":46359888003203,"sku":"3104-N","price":222.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3103-isolated-repeater-signal-galvanic-isolation-pr-electronics-signal-conditioning-process-solutions-corp-texas_48361e91-37ed-4f7b-ae1f-ed68c5a77dd0.jpg?v=1768515324"},{"product_id":"pr-3105-isolation-converter","title":"PR 3105 Isolation Converter","description":"\u003cp\u003eThe PR 3105 Isolated Converter is a high-performance DC signal \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converter Devices\"\u003econverter\u003c\/a\u003e module for industrial automation, SCADA systems, and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC interfaces\u003c\/a\u003e. Ideal for ensuring robust signal integrity in complex control environments, this converter, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/isolated-converter-3105\/\" title=\"PR electronics 3105 Isolation Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, provides galvanic isolation of standard analog current and voltage inputs, thus effectively eliminating ground loops and protecting downstream control systems from noise, transients, and interference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGalvanic separation of analog current and voltage signals.\u003c\/li\u003e\n\u003cli\u003eA competitive choice in terms of both price and technology for galvanic isolation of all signal types to SCADA systems or PLC equipment.\u003c\/li\u003e\n\u003cli\u003eHigh 3-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals are over-voltage protected, polarity protected and short-circuit protected.\u003c\/li\u003e\n\u003cli\u003eApproved for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3105 Isolation Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eEncased in an ultra-slim 6.1 mm DIN-rail housing, the PR 3105 allows up to 163 units per meter, enabling high-density installation in compact control cabinets. Its flexible 24 VDC (±30%) power supply can be fed through either power rail or terminal connectors, while factory-calibrated measurement ranges and DIP-switch configuration simplify setup and reduce commissioning time. The unit’s fast response time of \u0026lt;7 ms and excellent signal-to-noise ratio (\u0026gt;60 dB) deliver accurate, real-time signal transmission for demanding process applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt; 7 ms.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eInputs and outputs are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy to Install and Program\u003c\/h2\u003e\n\u003cp\u003eFeaturing three-port isolation with rated dielectric strength up to 2.5 kVAC, built-in over-voltage, polarity-reversal, and short-circuit protection, the 3105 offers dependable performance and long-term reliability. A front-panel LED provides clear status indication. Certified for challenging environments, including marine applications, this converter is an ideal choice for enhancing system protection and performance in critical industrial settings.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"pr-3015-isolation-converter-pr-electronics-automation-siganl-isolation-converter-process-solutions-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/pr-3015-isolation-converter-pr-electronics-automation-siganl-isolation-converter-process-solutions-psc-texas.jpg?v=1768517163\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3105: Supply via Power Rail Connector \/ Terminals","offer_id":46359914020995,"sku":"3105","price":197.0,"currency_code":"USD","in_stock":true},{"title":"3105-N: Supply via Terminals","offer_id":46359914053763,"sku":"3105-N","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3105-isolation-converter-pr-electronics-galvanized-isolator-signal-process-solutions-corp-psc-texas.jpg?v=1768517150"},{"product_id":"pr-3109-isolation-converter-splitter","title":"PR 3109 Signal Isolation Converter \/ Splitter","description":"\u003cp\u003eThe PR 3109 Signal Isolation Converter \/ Splitter is a precision \u003ca title=\"Signal Conditioning\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e module engineered to \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolate\u003c\/a\u003e, convert, and distribute standard DC analog signals in demanding industrial environments. Designed for \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems, this compact DIN-rail device provides galvanic separation of both current and voltage inputs, effectively removing ground loops and protecting sensitive control equipment from noise, transients, and interference. The 3109, from \u003ca title=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/isolated-repeater-3103\/\" href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/isolated-repeater-3103\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, features an integrated splitter functionality to deliver one input signal to two independent isolated outputs, thus enabling multiple measurement or control points to use the same source without compromising signal integrity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGalvanic separation of analog current and voltage signals.\u003c\/li\u003e\n\u003cli\u003eA competitive choice in terms of both price and technology for galvanic isolation of all signal types to SCADA systems or PLC equipment.\u003c\/li\u003e\n\u003cli\u003eHigh 4-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals are over-voltage protected, polarity protected and short-circuit protected.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in Safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e\n\u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3109 Signal Isolation Converter and Splitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 3109 features a slim 6.1 mm housing, allowing high-density installation, up to 163 units per meter, in tight control cabinets and panels. Pre-calibrated measurement ranges and DIP switch configuration simplify setup and eliminate the need for external calibration tools. With a fast response time (\u0026lt;7 ms), excellent signal-to-noise ratio (\u0026gt;60 dB), and high isolation rating of 2.5 kVAC, it ensures reliable, real-time performance across a wide ambient temperature range -13 to 158˚F (-25 to 70˚C).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt; 7 ms.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eInputs and outputs are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eAll terminals are protected against over-voltage, reverse polarity, and short circuits, and the unit is suitable for installation in Safe, Zone 2, or Division 2 areas, including marine applications. A front-panel LED provides clear operational status.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eUnits can be mounted side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 25px; margin-bottom: 16px; float: none;\" alt=\"PR-3109-Signal-isolation-converter-module-dc-analog-signal-converter-splitter-pr-electronics-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3109-Signal-isolation-converter-module-dc-analog-signal-converter-splitter-pr-electronics-process-solutions-corp-psc-texas.jpg?v=1768574718\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3109: Supply via Power Rail Connector \/ Terminals","offer_id":46362891976835,"sku":null,"price":266.0,"currency_code":"USD","in_stock":true},{"title":"3109-N: Supply via Terminals","offer_id":46362892009603,"sku":null,"price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3109-Signal-Isolation-Converter-Splitter-pr-electronics-signal-isolator-process-solutions-corp-psc-texas.jpg?v=1768575218"},{"product_id":"pr-3114-isolated-universal-converter","title":"PR 3114 Isolated Universal Converter","description":"\u003cp\u003eThe PR 3114 Isolated Universal Converter is a versatile, high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e module that's ideal for industrial process control and measurement applications. Acceptable with a wide range of inputs, including RTDs, thermocouples, ohmic sensors, potentiometers, milliamps, and voltage signals, this converter, from \u003ca title=\"PR electronics 3114 Isolated Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/isolated-universal-converter-3114\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, transforms virtually any analog sensor signal into \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e current or voltage outputs suitable for \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly valves or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control with standard analog output.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation of analog signals and measurement of floating signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3114 Isolated Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith robust 3-port galvanic isolation rated at 2.5 kVAC, the 3114 Isolated Universal Converter delivers exceptional protection against ground loops, electrical noise, and transient disturbances, thus safeguarding both measurement integrity and control equipment. Its slim 6.1 mm housing enables high-density DIN-rail mounting, up to 163 units per meter, making the PR 3114 ideal for space-constrained panels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e2.5 kVAC, 3-port galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Programming, Mounting, and Installation\u003c\/h2\u003e\n\u003cp\u003eAdvanced configuration and diagnostics are available via detachable communication interfaces and the PR 4590 ConfigMate, eliminating the need to open the unit for DIP-switch programming and allowing password-protected setups. Continuous internal data validation and a front-panel status LED further enhance reliability and ease of use. With certification for safe area and \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous locations\u003c\/a\u003e (FM Div. 2, ATEX\/IECEx\/UKEX Zone 2), as well as \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e, this isolated universal converter excels in temperature measurement linearization, resistance signal scaling, transmitter isolation, and general analog signal conditioning across demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration, monitoring, and diagnostics using PR 4500 detachable communication interfaces via the PR 4590 ConfigMate.\u003c\/li\u003e\n\u003cli\u003eAs the 3114 features electronic hardware switches, it is not necessary to open the device for setting of DIP-switches.\u003c\/li\u003e\n\u003cli\u003ePassword protection available for all programming.\u003c\/li\u003e\n\u003cli\u003eScrolling help text in 7 languages.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature. \u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3114-isolated-universal-converter-pr-electronics-analog-signal-converter-milliamps-potentiometers-process-solutions-corp-psc-texas.jpg?v=1768841050\" alt=\"PR-3114-isolated-universal-converter-pr-electronics-analog-signal-converter-milliamps-potentiometers-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3114: Supply via Power Rail Connector \/ Terminals","offer_id":46379926421635,"sku":"3114","price":267.0,"currency_code":"USD","in_stock":true},{"title":"3114-N: Supply via Terminals","offer_id":46379926454403,"sku":"3114-N","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3114-Isolated-Universal-Converter-PR-electronics-signal-converter-rtd-thermocouple-ohmic-sensor-potentiometer-process-solutions-texas.jpg?v=1768841076"},{"product_id":"pr-3117-bipolar-isolating-converter","title":"PR 3117 Bipolar Isolating Converter","description":"\u003cp\u003eThe PR 3117 Bipolar Isolating Converter is a high-precision \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Conditioning Device\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e module that's ideal for converting bipolar process voltage and current signals into stable unipolar outputs. The 3117, from \u003ca title=\"PR electronics 3117 Bipolar Isolating Converter\" href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/bipolar-isolated-converter-3117\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is suitable for industrial control and measurement systems. Built with exceptional accuracy, better than 0.05 % of span, and a fast response time of less than 7 ms, this bipolar \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolating\u003c\/a\u003e converter ensures rapid, reliable conversion even in demanding environments.\u003c\/p\u003e\n\u003cp\u003eFeaturing robust 3-port galvanic isolation, the PR 3117 protects your \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003econtrol system\u003c\/a\u003e by suppressing transients, eliminating ground loops, and reducing electrical noise. All terminals are safeguarded against over-voltage, polarity reversal, and short circuits, enhancing system longevity and safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIsolating converter for signal conversion of standard bipolar analog process signals into a unipolar analog signal.\u003c\/li\u003e\n\u003cli\u003eHigh 3-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eOffers protection for all terminals against over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in Safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3117 Bipolar Isolating Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThis slimline converter is just 6.1 mm wide. Thus, the 3117 is optimized for high-density DIN-rail installations, allowing up to 163 units per meter without air gaps. It supports flexible 24 V DC power via rail or connector and is suitable for installations in safe areas and hazardous locations (Zone 2\/Division 2), including marine applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt; 7 ms \/ \u0026gt; 100 Hz bandwidth — 10 Hz bandwidth damping possible via DIP switch.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eInputs and outputs are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSelectable signal ranges via DIP switches simplify configuration, while a front-panel LED provides clear status indication. Compliance with NAMUR NE21 ensures outstanding performance in challenging EMC environments. With a wide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C), the PR 3117 Bipolar Isolating Converter delivers reliable, adaptable signal conversion for diverse industrial applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast and easy configuration of factory-calibrated measurement ranges via DIP switches.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3117-bipolar-isolating-converter-pr-electronics-signal-isolation-bipolar-converter-isolator-process-solutions-psc-texas.jpg?v=1768843558\" alt=\"PR-3117-bipolar-isolating-converter-pr-electronics-signal-isolation-bipolar-converter-isolator-process-solutions-psc-texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3117: Supply via Power Rail Connector \/ Terminals","offer_id":46379934613635,"sku":"3117","price":225.0,"currency_code":"USD","in_stock":true},{"title":"3117-N: Supply via Terminals","offer_id":46379934646403,"sku":"3117-N","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3117-Bipolar-Isolating-Converter-PR-electronics-signal-converter-isolator-process-solutions-corp-texas.jpg?v=1768843939"},{"product_id":"pr-3118-bipolar-isolated-converter-splitter","title":"PR 3118 Bipolar Isolated Converter \/ Splitter","description":"\u003cp\u003eThe PR 3118 Bipolar Isolated Converter \/ Splitter is a versatile and precise \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Conditioning Device\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e module that's ideal for industrial process control and measurement systems. The 3118, from \u003ca title=\"PR electronics 3118 Bipolar Isolating Converter\" href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3100\/bipolar-isolated-converter-splitter-3118\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, converts bipolar voltage and current process signals into two \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e analog outputs, thus allowing one input to drive dual unipolar signals. This module is ideal for feeding multiple controllers or recording systems from a single source.\u003c\/p\u003e\n\u003cp\u003eBuilt for reliability and accuracy, the PR 3118 Bipolar Isolating Converter delivers excellent performance, with accuracy better than 0.05 % of span, and a fast response time of less than 7 ms. Its high 4-port galvanic isolation (2.5 kVAC) protects equipment from ground loops, noise, and transients, while floating inputs and outputs ensure stable signal transmission in harsh environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIsolating converter and splitter for signal conversion of standard bipolar analog process signals into two individual unipolar analog signals.\u003c\/li\u003e\n\u003cli\u003eHigh 4-port isolation provides surge suppression that protects the control system from transients and noise and also eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eThe analog output can easily configure and program to be bipolar in the ranges ±10 mA and ±20 mA.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection against over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in Safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3118 Bipolar Isolated Converter \/ Splitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFlexible DIP-switch selection lets users configure input and output ranges, including bipolar ±10 mA and ±20 mA, without external tools. The slim 6.1 mm DIN-rail housing supports high-density installations with up to 163 units per meter. A front-panel LED clearly indicates status, and robust terminal protection guards against over-voltage, polarity reversal, as well as short circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible 24 VDC (±30%) supply via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt; 7 ms \/ \u0026gt; 100 Hz bandwidth — 10 Hz bandwidth damping possible via DIP switch.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, the PR 3118 Bipolar Isolated Converter ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC. \u003c\/li\u003e\n\u003cli\u003eInputs and outputs are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eWith certifications for safe areas and hazardous locations (Zone 2\/Division 2) and compliant with NAMUR NE21 for EMC immunity, the 3118 is a compact, reliable solution for splitting and isolating analog process signals in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast and easy configuration of factory-calibrated measurement ranges via DIP switches.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature. \u003c\/li\u003e\n\u003cli\u003eUnits can be supplied separately or installed on PR 9400 power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3118-bipolar-isolated-converter-splitter-pr-electronics-signal-isolator-signal-splittter-converter-process-solutions-corp-psc-texas.jpg?v=1768846483\" alt=\"PR-3118-bipolar-isolated-converter-splitter-pr-electronics-signal-isolator-signal-splittter-converter-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3118: Supply via Power Rail Connector \/ Terminals","offer_id":46379992514691,"sku":"3118","price":274.0,"currency_code":"USD","in_stock":true},{"title":"3118-N: Supply via Terminals","offer_id":46379992547459,"sku":"3118-N","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3118-Biplar-Isolated-Converter-splitter-pr-electronics-signal-isolator-process-solutions-corp-texas.png?v=1768846502"},{"product_id":"pr-4225-universal-fl-ff-converter","title":"PR 4225 Universal f\/l-f\/f Converter","description":"\u003cp\u003eThe PR 4225 Universal f\/I-f\/f Converter is a versatile industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device for converting a wide range of sensor and frequency inputs into precise analog, frequency or relay outputs. The 4225 frequency converter, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4200\/universal-f-i-f-f-converter-4225\/\" title=\"PR electronics 4225 Universal f\/I-f\/f Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for advanced automation, \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eprocess control\u003c\/a\u003e, and \u003ca title=\"Industrial Wireless Monitoring Systems\" href=\"https:\/\/www.psctexas.shop\/products\/industrial-wireless-monitoring-systems\"\u003emonitoring systems\u003c\/a\u003e. Built to handle signals from \u003ca title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e, NPN, PNP, TTL, S0, tacho, and switch sources, the PR 4225 measures frequencies up to 100 kHz and delivers configurable bipolar or unipolar current (±23 mA \/ 0-23 mA) and buffered voltage (±10 VDC) outputs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures frequencies up to 100 kHz.\u003c\/li\u003e\n\u003cli\u003eActive and passive current output ±23 mA \/ 0-23 mA.\u003c\/li\u003e\n\u003cli\u003eBuffered voltage output ±10 VDC.\u003c\/li\u003e\n\u003cli\u003eLinearization: Linear or square root function.\u003c\/li\u003e\n\u003cli\u003e2-point process calibration.\u003c\/li\u003e\n\u003cli\u003eProgrammable trigger levels -0.05-6.5 V.\u003c\/li\u003e\n\u003cli\u003eProgrammable sensor supply 5-17 V.\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor error detection.\u003c\/li\u003e\n\u003cli\u003eAdvanced configurable input limits for increased safety.\u003c\/li\u003e\n\u003cli\u003eDigital output: NPN \u0026amp; PNP; 0-100 kHz with programmable logic level 5-24 V.\u003c\/li\u003e\n\u003cli\u003eOutput relay with windows, setpoint, and latch functionality.\u003c\/li\u003e\n\u003cli\u003eSimulation of process value during commissioning and maintenance.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection from over-voltage (24 VDC), polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe PR 4225 Universal f\/I-f\/f Converter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 4225 frequency converter correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4225 Universal f\/l-f\/f Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing programmable trigger levels and linearization functions (linear or square root), the PR 4225 Universal f\/I-f\/f Converter supports two-point calibration and advanced sensor error detection, thus making it ideal for process interfacing, motion measurement, and frequency-to-signal applications. Its universal power supply (21.6-253 VAC \/ 19.2-300 VDC) and robust 3-port galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e (2.3 kVAC) ensure reliable performance in industrial environments, while compliance with NAMUR NE21\/NE43 and support for SIL 2\/PL \"d\" safety levels enhance system integrity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy \u0026lt; 0.06% \/ span.\u003c\/li\u003e\n\u003cli\u003eTemperature coefficient 0.006% \/ ˚C. \u003c\/li\u003e\n\u003cli\u003eResponse time \u0026lt; 30 ms.\u003c\/li\u003e\n\u003cli\u003e2.3 kVAC, 3-port galvanic isolation. \u003c\/li\u003e\n\u003cli\u003eNAMUR NE21 and NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration, diagnostics, and remote monitoring are easily managed via the detachable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e communication interface, which also enables \u003ca rel=\"noopener\" title=\"Modbus Protocol\" href=\"https:\/\/www.modbus.org\/\" target=\"_blank\"\u003eModbus\u003c\/a\u003e and \u003ca rel=\"noopener\" title=\"Bluetooth Association\" href=\"https:\/\/www.bluetooth.com\/\" target=\"_blank\"\u003eBluetooth\u003c\/a\u003e connectivity using the \u003ca rel=\"noopener\" title=\"PR Process Supervisor App\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/pps-app\/\" target=\"_blank\"\u003ePR Process Supervisor (PPS)\u003c\/a\u003e app. With fast response time (\u0026lt; 30 ms), over-voltage and short-circuit protection on all terminals, the PR 4225 Universal f\/I-f\/f Converter delivers precision, flexibility, and industrial-grade reliability for complex signal conversion needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration, monitoring, and diagnostics using the PR 4500 detachable communication interfaces.\u003c\/li\u003e\n\u003cli\u003eProduct-specific functionality includes communication via Modbus and Bluetooth using our PR Process Supervisor (PPS) application, available for iOS and Android.\u003c\/li\u003e\n\u003cli\u003eAll programming can be password protected.\u003c\/li\u003e\n\u003cli\u003eScrolling help text in 7 languages.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail – even at 140˚F (60˚C) ambient temperature.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"pr-4225-universal-f-i-f-f-converter-pr-electronics-universal-frequency-converter-fi-ff-process-solutions-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/pr-4225-universal-f-i-f-f-converter-pr-electronics-universal-frequency-converter-fi-ff-process-solutions-psc-texas.jpg?v=1769179921\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"4225A: 1 Analog and 1 Relay Output","offer_id":46391875567747,"sku":"4225A","price":319.0,"currency_code":"USD","in_stock":true},{"title":"4225B: 2 Relay Output","offer_id":46391875600515,"sku":"4225B","price":305.0,"currency_code":"USD","in_stock":true},{"title":"4225C: 1 Analog or 1 Frequency Output","offer_id":46391875633283,"sku":"4225C","price":352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4225-universal-f-i-f-f-converter-pr-electronics-universal-frequency-converter-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769179978"},{"product_id":"pr-3225-universal-frequency-converter","title":"PR 3225 Universal Frequency Converter","description":"\u003cp\u003eThe PR 3225 Universal Frequency Converter is ideal for protecting rotating machinery by monitoring critical speed, over speed, and under speed. Additionally, it's useful for synchronous motors that turn or vibrate. For this purpose, the 3225, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/isolation\/3200\/universal-frequency-converter-3225\/\" title=\"PR electronics 3225 Universal Frequency Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, can also match new speed sensors to original units and control process \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/pressure-transducers\" title=\"Pressure Transducers\"\u003epressure\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/flow-instrumentation\" title=\"Flow Instrumentation\"\u003eflow\u003c\/a\u003e without the use of a separate controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasures frequencies up to 100 kHz\u003c\/li\u003e\n\u003cli\u003eactive current output\u003c\/li\u003e\n\u003cli\u003ebuffer voltage output 10 VDC\u003c\/li\u003e\n\u003cli\u003e2-point process calibration\u003c\/li\u003e\n\u003cli\u003euser-programmable trigger levels -0.05 to 6.5 V and sensor supply 5 to 17 V\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e sensor error detection\u003c\/li\u003e\n\u003cli\u003eoutput relay with windows, set point, and latch functionality\u003c\/li\u003e\n\u003cli\u003esimulation of process value during commissioning \/ maintenance\u003c\/li\u003e\n\u003cli\u003efast response time, with simultaneous sensor error detection (PATENTED)\u003c\/li\u003e\n\u003cli\u003eall terminals have over-voltage protection, polarity protection, and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eATEX certification for installation in \u003cmeta charset=\"utf-8\"\u003e\n\u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3225 Universal Frequency Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFor easy deployment, the typical configuration can be achieved via DIP-switch programming. With the optional PR 4590 ConfigMate and communication interfaces in the \u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500 Series\u003c\/a\u003e, it is easy to monitor and program the measurement point and take advantage of the advance features of the PR 3225. Due to the strong foundation of the PR electronics 3000 series with powerful features such as high accuracy, fast response time, and low temperature drift, the PR 3225 is a flexible and easy-to-use product when measuring frequency signals. With outstanding EMC specifications that meet or exceed industry standards and its 5-year warranty, users can look forward to many years of trouble-free operation with PR 3225.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccuracy \u0026lt; 0.06% \/ span\u003c\/li\u003e\n\u003cli\u003eresponse time \u0026lt; 30 ms\u003c\/li\u003e\n\u003cli\u003e2.5 kVAC, 3-port galvanic isolation\u003c\/li\u003e\n\u003cli\u003ewide ambient temperature range -13 to 158˚F (-25 to 70°C)\u003c\/li\u003e\n\u003cli\u003eNAMUR NE21, NE43\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat are Frequency to Current Converters\u003c\/h2\u003e\n\u003cp\u003eThe process industry requires measurement and control of many process variables. Speed and flow rate are two such variables, where safety and product delivery demand accurate process control. Sensors used to measure speed often take the form of proximity sensors, which detect a target as it passes by the sensor, thus resulting in a pulse or frequency output proportional to the speed. To enable these signals to interface with downstream equipment, the pulses or frequencies are often converted to a current or voltage signal. Frequency to current converters such as the \u003ca title=\"PR electronics 4225 Universal f\/l-f\/f Converter\" href=\"https:\/\/www.psctexas.shop\/products\/pr-4225-universal-fl-ff-converter\"\u003ePR 4225\u003c\/a\u003e and PR 3225 are ideal for this purpose.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Programming and Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eeasy configuration via DIP-switches\u003c\/li\u003e\n\u003cli\u003efactory calibration in all selectable measurement ranges\u003c\/li\u003e\n\u003cli\u003econfiguration, monitoring, and diagnostics using PR 4500 detachable communication interfaces via the PR 4590 ConfigMate\u003c\/li\u003e\n\u003cli\u003eall programming can have password protection\u003c\/li\u003e\n\u003cli\u003escrolling help text in 7 languages\u003c\/li\u003e\n\u003cli\u003eunits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature\u003c\/li\u003e\n\u003cli\u003eunits can receive power separately or together through a PR 9400 power rail\u003c\/li\u003e\n\u003cli\u003ethe narrow 6.1 mm housing allows up to 163 units per meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpeed Monitoring with a Frequency Converter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eindependent speed measuring with alarm to monitor critical equipment\u003c\/li\u003e\n\u003cli\u003everification of critical functions to ensure accurate measurement\u003c\/li\u003e\n\u003cli\u003efrequency converters are a great alternative to other tachometers, for example, a variable frequency device (VFD), rotation speed monitor,  or frequency transmitter such as S1SD-1FI-1R, MCR-2-F-UI-2902056, Jumpflex 857-500, KFD2-UFC-1.D, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-3225-Universal-Frequency-Converter-PR-electronics-signal-conversion-module-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3225-Universal-Frequency-Converter-PR-electronics-signal-conversion-module-process-solutions-corp-psc-texas.jpg?v=1768921395\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3225A: Analog Output; Supply via Power Rail Connector \/ Terminals","offer_id":46382233059459,"sku":"3225A","price":278.0,"currency_code":"USD","in_stock":true},{"title":"3225A-N: Analog Output; Supply via Terminals","offer_id":46382233092227,"sku":"3225A-N","price":278.0,"currency_code":"USD","in_stock":true},{"title":"3225B: Alarm Relay Output; Supply via Power Rail Connector \/ Terminals","offer_id":46382233124995,"sku":"3225B","price":263.0,"currency_code":"USD","in_stock":true},{"title":"3225B-N: Alarm Relay Output; Supply via Terminals","offer_id":46382233157763,"sku":"3225B-N","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3225-A-Universal-Frequency-Converter-PR-electronics-signal-conditioning-process-solutions-corp-texas.jpg?v=1768921415"},{"product_id":"pr-2261-mv-transmitter","title":"PR 2261 mV Transmitter","description":"\u003cp\u003eThe PR 2261 mV Transmitter is a versatile industrial millivolt to current\/voltage \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e that's ideal for precise measurement and control applications. The 2261, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/special-devices\/2200\/mv-transmitter-2261\/\" target=\"_blank\" title=\"PR electronics 2261 mV Transmitter\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is capable of converting bipolar mV signals from strain gauges, load cells, and other low-level transducers into standard analog outputs. Furthermore, the PR 2261 supports \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e for weighing systems, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel control\u003c\/a\u003e, tensile force measurement, tank filling\/draining, and general industrial automation tasks. Its front-programmable interface with a 3-digit LED display and push buttons makes calibration as well as configuration fast and intuitive.\u003c\/p\u003e\n\u003cp\u003eBuilt for industrial environments, the 2261 accepts programmable -40 to 100 mVDC input and can output either 0-20 mA or 0-10 VDC signals to \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS units, or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\" title=\"Data Logging and Acquisition\"\u003edata acquisition\u003c\/a\u003e systems. A selectable NPN\/PNP digital input allows external taring functions, thus helping streamline load cell applications. Optional transducer power from 5-13 VDC is available, supporting multiple parallel load cells while a sense input compensates for cable resistance to ensure signal accuracy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA multifunction user interface consisting of three push buttons and a 3-digit LED display for programming.\u003c\/li\u003e\n\u003cli\u003eThe PR 2261 converts bipolar mV signals from transducers supplied directly by the device to standard current \/ voltage signals. \u003c\/li\u003e\n\u003cli\u003eThe 2261 mV Transmitter is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion \/ amplification etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 2261 mV Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eCompact yet robust, the PR 2261 offers a front error LED for quick fault identification and is compatible with standard 11-pole sockets adaptable for DIN-rail or panel mounting. Its flexible programming, reliable performance, and broad application range make the 2261 mV Transmitter an ideal choice for industrial signal conversion and process measurement systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFront error LED.\u003c\/li\u003e\n\u003cli\u003eThe analog input can be programmed for voltage in the range -40 to 100 mVDC.\u003c\/li\u003e\n\u003cli\u003eUsers can select either NPN or PNP for the digital signal.\u003c\/li\u003e\n\u003cli\u003eTaring can either be by way of the digital input or from the front interface.\u003c\/li\u003e\n\u003cli\u003eUsers can program the analog output to current in the range 0 to 20 mA as well as voltage in the range 0 to 10 VDC.\u003c\/li\u003e\n\u003cli\u003eUsers can program the transducer supply to 5 to 13 VDC from the front. \u003c\/li\u003e\n\u003cli\u003eUsers must ensure a maximum load of 230 mA (for example, 6 parallel 350 Ω load cells).\u003c\/li\u003e\n\u003cli\u003eSense input (with transducer supply used) for compensation for cable resistance to the transducer.\u003c\/li\u003e\n\u003cli\u003eMounting for a standard 11-pole socket which can adapt for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-2261-mv-transmitter-pr-electronics-millivolt-converter-signal-conditioning-module-process-solutions-psc-texas.jpg?v=1769011506\" alt=\"PR-2261-mv-transmitter-pr-electronics-millivolt-converter-signal-conditioning-module-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":46384510500995,"sku":"2261","price":563.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-2261-mV-Transmitter-PR-electronics-signal-converter-millivolt-process-solutions-corp-psc-texas.jpg?v=1769011530"}],"url":"https:\/\/www.psctexas.shop\/collections\/signal-converters.oembed?page=2","provider":"Process Solutions Corp.","version":"1.0","type":"link"}