{"title":"Signal Isolation Devices","description":"","products":[{"product_id":"pr-6437-din-rail-temperature-transmitter","title":"PR 6437 DIN-Rail Temperature Transmitter","description":"\u003cp\u003eThe PR 6437 DIN-Rail Temperature Transmitter is a high-performance industrial \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and also process measurement in automation systems. The 6437 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, offers flexible sensor support including RTD, thermocouple (TC), bipolar mV, linear resistance, and potentiometer inputs. As a result, the PR 6437 delivers accurate 4-20 mA output with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 communication support for advanced diagnostics, remote configuration, and data access. Its wide compatibility makes this \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e ideal for integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management software in manufacturing, energy, chemical processing, as well as HVAC environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of thermocouple and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eIdeal for critical applications requiring superior accuracy and\/or sensor redundancy as well as drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 6437 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6437A DIN-Rail Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6400\/2-wire-hart-7-temperature-transmitter-6437a\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 6437A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6437D Ex DIN-Rail Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6400\/2-wire-hart-7-temperature-transmitter-6437d\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 6437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6437 DIN-Rail Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6437 DIN-Rail temperature transmitter supports single or true dual inputs with sensor redundancy and drift detection. Thus, the 6437 Series ensures reliable measurement and improves uptime, even in critical applications. Dual input mapping options allow dynamic reporting of average, differential, minimum\/maximum, and other process variables for enhancing control as well as analysis. This DIN-rail temperature transmitter features programmable damping (0-60s) and excellent signal-to-noise performance to deliver stable outputs under varying conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter, accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime. \u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example: dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span as well as ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen in addition to custom linearization. \u003c\/li\u003e\n\u003cli\u003eProgrammable input limits with runtime metering ensure maximum process traceability and also provide sensor out of range protection. \u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\" title=\"International Electrotechnical Commission\" rel=\"noopener\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" title=\"NAMUR Association\" rel=\"noopener\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eFailure rates for 6437xxSx correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eAble to withstand demanding industrial environments, the PR 6437 offers 2.5 kVAC galvanic isolation, complies with NAMUR NE21\/NE43\/NE44\/NE89, and is also fully assessed to IEC 61508 SIL 2\/3. As a result, the PR 6437 \u003cmeta charset=\"utf-8\"\u003eDIN-Rail Temperature Transmitter is suitable for safety-critical systems. With up to 84 channels per meter on DIN-rail mounts as well as configuration via HART or PR Loop Link, this transmitter combines precision, connectivity, and reliability for modern process control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 inputs per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via \u003ca href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\" title=\"PReset Programming Software\" rel=\"noopener\"\u003ePReset\u003c\/a\u003e using the PR 5909 Loop Link \/\u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\" title=\"HART Protocol\" rel=\"noopener\"\u003eHART\u003c\/a\u003e modem, or by Asset Management tool, for example: \u003ca href=\"https:\/\/pactware.com\/\" target=\"_blank\" title=\"PACTware Programming Software\" rel=\"noopener\"\u003ePactware\u003c\/a\u003e, AMS, HART communicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC.jpg?v=1770236244\" alt=\"PR-6347-DIN-Rail-Temperature-Transmitter-PR-electronics-x1-Signal-Isolation-Temperature-Sensor-Intrinsically-Safe-Signal-Transmitter-Temp-Measurement-Process-Solutions-Texas-PSC\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-P.jpg?v=1770236267\" alt=\"PR-6437-DIN-Rail-Temperature-Transmitter-PR6437-6437A-6347D-x2-Industrial-Temperature-Transmitter-HART-Protocol-Signal-Isolator-Intrinsically-Safe-Temp-Sensor-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46471256801411,"sku":"6437A1--","price":577.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46471256834179,"sku":"6437A1S-","price":610.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46471256866947,"sku":"6437A1-M","price":602.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46471256899715,"sku":"6437A1SM","price":638.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46471256932483,"sku":"6437A2--","price":399.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46471256965251,"sku":"6437A2S-","price":700.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46471256998019,"sku":"6437A2-M","price":691.0,"currency_code":"USD","in_stock":true},{"title":"6437A: General Purpose; Zone 2 and 22; Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46471257030787,"sku":"6437A2SM","price":724.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46471257063555,"sku":"6437D1--","price":692.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46471257096323,"sku":"6437D1S-","price":726.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46471257129091,"sku":"6437D1-M","price":719.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46471257161859,"sku":"6437D1SM","price":755.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46471257194627,"sku":"6437D2--","price":781.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46471257227395,"sku":"6437D2S-","price":817.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46471257260163,"sku":"6437D2-M","price":807.0,"currency_code":"USD","in_stock":true},{"title":"6437D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46471257292931,"sku":"6437D2SM","price":844.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6437-A-DIN-Rail-Temperature-Transmitter-PR-electronics-industrial-temperature-measurement-HART-protocol-2-wire-temp-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770236286"},{"product_id":"pr-9113b-ex-ma-temperature-converter","title":"PR 9113B Ex mA Temperature Converter","description":"\u003cp\u003eThe PR 9113B Ex mA Temperature Converter is a high-precision temperature to current \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e for demanding industrial and process-automation environments. The 9113B is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113B, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interface\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eThe 9113B is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113B Ex mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113B Ex mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113B includes 2.6 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113B Ex mA Temperature Converter has certification for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113B correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113B is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113B Ex mA Temperature Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113B can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408025\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878365257859,"sku":"9113B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-B-Ex-mA-Temperature-Converter-PR-electronics-isolated-temperature-transmitter-intrinsically-safe-SIL-temp-sensor-for-RTD-thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408686"},{"product_id":"pr-5437-hart-7-temperature-transmitter","title":"PR 5437 HART 7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5437 HART 7 Temperature Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437 Series, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 5437 Series are galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437A HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437a\/\" target=\"_blank\"\u003ePR 5437A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437B HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437b\/\" target=\"_blank\"\u003ePR 5437B\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5437D HART 7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437d\/\" target=\"_blank\"\u003ePR 5437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437 HART 7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437 HART 7 Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437 maximizes uptime and simplifies maintenance planning. The PR 5437 Series features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437 Series ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437 HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461156982915,"sku":"5437A1--","price":542.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157015683,"sku":"5437A1S-","price":579.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157048451,"sku":"5437A1-M","price":568.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157081219,"sku":"5437A1SM","price":605.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157113987,"sku":"5437A2--","price":605.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157146755,"sku":"5437A2S-","price":645.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157179523,"sku":"5437A2-M","price":635.0,"currency_code":"USD","in_stock":true},{"title":"5437A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157212291,"sku":"5437A2SM","price":669.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461157245059,"sku":"5437B1--","price":597.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157277827,"sku":"5437B1S-","price":635.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157310595,"sku":"5437B1-M","price":623.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157343363,"sku":"5437B1SM","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157376131,"sku":"5437B2--","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157408899,"sku":"5437B2S-","price":695.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157441667,"sku":"5437B2-M","price":688.0,"currency_code":"USD","in_stock":true},{"title":"5437B: Zone 0; 1; 2; 21; 22; M1 \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157474435,"sku":"5437B2SM","price":723.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ None - Standard","offer_id":46461157507203,"sku":"5437D1--","price":597.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ S: SIL","offer_id":46461157539971,"sku":"5437D1S-","price":638.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ M: Marine","offer_id":46461157572739,"sku":"5437D1-M","price":623.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 1: Single Input - 4 Terminals \/ SM: SIL and Marine","offer_id":46461157605507,"sku":"5437D1SM","price":663.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ None - Standard","offer_id":46461157638275,"sku":"5437D2--","price":661.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ S: SIL","offer_id":46461157671043,"sku":"5437D2S-","price":695.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ M: Marine","offer_id":46461157703811,"sku":"5437D2-M","price":688.0,"currency_code":"USD","in_stock":true},{"title":"5437D: Zone 0; 1; 2; 21; 22; M1 \/ Class 1; Div 1; Groups A B C D \/ 2: Dual Input - 7 Terminals \/ SM: SIL and Marine","offer_id":46461157736579,"sku":"5437D2SM","price":723.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437A-HART-Temperature-Transmitter-PR-electronics-signal-isolation-temperatuer-transmitter-process-solutions-texas.jpg?v=1770052636"},{"product_id":"pr-5437b-2-wire-hart-temperature-transmitter","title":"PR 5437B 2-wire HART Temperature Transmitter","description":"\u003cp\u003eThe PR 5437B 2-wire HART Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437B, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eThe 5437B is galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features multiple certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437b\/\" title=\"PR electronics 5437B HART 7 Temperature Transmitter\" target=\"_blank\"\u003ePR 5437B\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437B 2-wire HART Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437B 2-wire HART Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437B maximizes uptime and simplifies maintenance planning. The PR 5437B features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437B ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437B HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367420547,"sku":"5437B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-5437B-5437D-hazardous-area-temp-sensor-process-solutions-corp-psc-texas.jpg?v=1770052636"},{"product_id":"pr-5437d-hart-7-temperature-transmitter","title":"PR 5437D HART 7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5437D HART 7 Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precision temperature measurement and reliable \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in process automation systems. The 5437D, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature measurement of a wide range of TC and RTD types.\u003c\/li\u003e\n\u003cli\u003eConversion of wide span linear resistance and potentiometer inputs.\u003c\/li\u003e\n\u003cli\u003eConversion of bipolar mV signals to 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eIntegration into asset management schemes.\u003c\/li\u003e\n\u003cli\u003eCritical applications requiring superior accuracy and\/or sensor redundancy and drift detection.\u003c\/li\u003e\n\u003cli\u003eModels in the 5437D are galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5400\/2-wire-hart-7-temperature-transmitter-5437d\/\" title=\"PR electronics 5437D HART 7 Temperature Transmitter\" target=\"_blank\"\u003ePR 5437D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5437D HART 7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eExcelling in the most demanding industrial environments, the PR 5437D HART 7 Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437D maximizes uptime and simplifies maintenance planning. The PR 5437D features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue dual input transmitter.\u003c\/li\u003e\n\u003cli\u003eHigh density 7-terminal design accepts the widest range of dual input combinations.\u003c\/li\u003e\n\u003cli\u003eSensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.\u003c\/li\u003e\n\u003cli\u003eSensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.\u003c\/li\u003e\n\u003cli\u003eDynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum\/maximum tracking.\u003c\/li\u003e\n\u003cli\u003eGroundbreaking digital and analog signal accuracy over full input span and ambient conditions.\u003c\/li\u003e\n\u003cli\u003eExtensive sensor matching including Callendar Van Dusen as well as custom linearization.\u003c\/li\u003e\n\u003cli\u003eProgrammable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.\u003c\/li\u003e\n\u003cli\u003eModel 5437xxSx provides failure rates that correspond to Performance Level \"d\" according to ISO-13849.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2\/3 functional safety) make the PR 5437D ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437D HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-PR5437-5437A-5437B-5437D-hart-protocol-temp-transmitter-intrinsically-safe-atex-industrial-temperature-sensor-process-solutions-c.jpg?v=1770051859\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367453315,"sku":"5437D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5437-HART-7-Temperature-Transmitter-PR-electronics-5437B-5437D-hazardous-area-temp-sensor-process-solutions-corp-psc-texas.jpg?v=1770052636"},{"product_id":"pr-3113-hart-temperature-converter","title":"PR 3113 HART Temperature Converter","description":"\u003cp\u003ePR Electronics 3113 HART Temperature Converter is a high-performance, \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e temperature conversion module designed for demanding industrial measurement environments. This compact yet powerful HART \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e accurately transforms signals from standard Pt100 RTDs and J\/K thermocouples into isolated analog current and \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e 7 digital outputs, making the 3113, from \u003ca title=\"PR electronics 3113 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3100\/hart-temperature-converter-3113\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ideal for integration with modern control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3113 HART temperature converter measures a standard Pt100, TC J and K temperature sensor and provides an isolated active analog current and HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 3 port isolation provides surge suppression and protects the control system from transients and noise.\u003c\/li\u003e\n\u003cli\u003eThe 3113 can mount in the safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003ePR 3113 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt with exceptional precision, better than 0.05 % of span, the 3113 ensures reliable, repeatable temperature measurement critical to process control, quality assurance, and safety systems. Its selectable internal or external cold junction compensation and switchable response time (from a rapid 60 ms up to 60 s) provide flexibility across diverse applications.\u003c\/p\u003e\n\u003cp\u003eEngineered with a slimline 6.1 mm housing, this HART temperature converter maximizes space efficiency on DIN rails, thus allowing up to 163 units per meter without gaps. Rugged galvanic isolation and robust EMC performance safeguard your system from electrical noise and transient surges, while compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 standards supports stable operation even in harsh industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly powered by 24 VDC (±30%) via power rail or connectors.\u003c\/li\u003e\n\u003cli\u003eA 60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 3113 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe device meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eA visible green LED indicates operational status of the unit and the input sensor.\u003c\/li\u003e\n\u003cli\u003eAll terminals are protected against overvoltage and polarity error. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eInstallation and configuration are effortless with DIP-switch settings for over 1,000 factory-calibrated temperature ranges and selectable HART modes, thus offering full read-write access for advanced device setup. Suitable for safe areas as well as Zone 2 \/ Div. 2 hazardous locations, the PR electronics 3113 delivers precision, flexibility, and reliability in a compact, industrial-grade package.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units to mount per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas.jpg?v=1768842513\" alt=\"PR-3113-HART-Temperature-Converter-PR-electronics-Pt100-TC-Thermocopule-converter-signal-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"3113: Supply via Power Rail Connector \/ Terminals","offer_id":46379828576387,"sku":"3113","price":304.0,"currency_code":"USD","in_stock":true},{"title":"3113-N: Supply via Terminals","offer_id":46379828609155,"sku":"3113-N","price":304.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3113-HART-Temperature-Converter-PR-electronics-rtd-pt100-temp-signal-converter-process-solutions-corp-texas.jpg?v=1768842546"},{"product_id":"pr-3331-loop-powered-temperature-converter","title":"PR 3331 Loop-Powered Temperature Converter","description":"\u003cp\u003eThe PR 3331 Loop-Powered Isolated Temperature Converter is a precision \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for converting industrial temperature sensor inputs into reliable \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e 4–20 mA current loop outputs. Ideal for process automation, control systems, and industrial instrumentation, the 3331, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/temperature-converter-loop-powered-isolated-3331\/\" title=\"PR electronics 3331 Loop-Powered Temperature Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports standard temperature sensors including Pt100 RTDs and thermocouples (TC J \u0026amp; K). Its loop-powered design eliminates the need for external power, thus simplifying installation and reducing infrastructure costs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3331 is a loop-powered \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e that measures a standard Pt100, thermocouple (TC) J and K temperature sensor, and provides an isolated passive analog current output signal.\u003c\/li\u003e\n\u003cli\u003eHigh 2 port isolation provides surge suppression and protects the \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003econtrol system\u003c\/a\u003e from transients and noise.\u003c\/li\u003e\n\u003cli\u003eThe 3331 can mount in the safe area or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3331 Loop-Powered Temperature Converter\u003c\/h2\u003e\n\u003cp\u003eFeaturing excellent conversion accuracy better than 0.05 % of span and selectable fast response times as low as \u0026lt;30 ms, the PR 3331 Loop-Powered Temperature Converter ensures accurate, real-time temperature data for critical process monitoring. Robust galvanic isolation (2.5 kVAC) and compliance with \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21\/NE43 standards deliver superior noise suppression and sensor error handling, even in harsh electrical environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop powered by 5.5 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary. \u003c\/li\u003e\n\u003cli\u003eSelectable internal\/external CJC.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 3331 provides top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThis loop-powered temperature converter meets the NAMUR NE43 standard defining out of range in addition to sensor error output values.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection against overvoltage as well as polarity error.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eExcellent signal\/noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe slim 6.1 mm DIN-rail housing enables high-density mounting in control panels, supporting up to 163 units per meter without gaps. Easy configuration via DIP switches provides access to more than 1000 factory-calibrated temperature ranges. Furthermore, selectable internal or external cold junction compensation enhances flexibility for thermocouple applications.\u003c\/p\u003e\n\u003cp\u003eBuilt for industrial reliability, the PR 3331 operates across a wide temperature range \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C) and offers certification for Safe Areas as well as Zone 2\/Division 2 and marine applications. Thus the 3331 loop-powered temperature converter is a versatile choice for industrial temperature measurement and process control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units to be mounted per meter of DIN rail, without any air gap between units.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range of \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-3331-loop-powered-temperature-converter-pr-electronics-signal-conditioning-temp-converter-process-solutions-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3331-loop-powered-temperature-converter-pr-electronics-signal-conditioning-temp-converter-process-solutions-psc-texas.jpg?v=1768933534\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367649923,"sku":"3331","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3331-loop-powered-temperature-converter-pr-electronics-signal-converter-thermocouple-pt100-rtd-process-solutions-corp-psc-texas.jpg?v=1768933966"},{"product_id":"pr-3337-hart-temperature-converter","title":"PR 3337 HART Temperature Converter","description":"\u003cp\u003eThe PR 3337 HART Temperature Converter is a high-performance \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e ideal for industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e, automation, and instrumentation systems where accurate temperature measurement and digital communication are essential. This \u003ca title=\"HART Protocol\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e-compatible temperature converter accepts standard Pt100 RTD and thermocouple (TC J \u0026amp; K) sensor inputs. The 3337, from \u003ca title=\"PR electronics 3337 HART Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/hart-temperature-converter-loop-powered-3337\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, then provides both an \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e analog 4–20 mA output and a digital HART 7 communication signal for advanced diagnostics and configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3337 HART temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated passive analog current as well as a HART signal output.\u003c\/li\u003e\n\u003cli\u003eHigh 2-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection from over-voltage, polarity, and short-circuit.\u003c\/li\u003e\n\u003cli\u003eThe device can mount in safe areas or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3337 HART Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 3337 HART Temperature Converter delivers excellent conversion accuracy, better than 0.05 % of span, as well as selectable fast or damped response times (60 ms\/60 s). Thus, the 3337 is ideal for responsive feedback in industrial control loops. Its robust 2-port galvanic isolation (2.5 kVAC) eliminates ground loops, suppresses noise and transients, and protects sensitive PLC, DCS, and SCADA inputs.\u003c\/p\u003e\n\u003cp\u003eFeaturing more than 1,000 pre-calibrated temperature ranges and selectable internal\/external cold junction compensation, this loop-powered HART temperature converter offers flexible configuration with DIP switches or full HART read\/write capability. The slim 6.1 mm DIN-rail housing supports high-density panel mounting, thus saving space in control cabinets. Furthermore, rugged terminal protection guards against over-voltage, polarity reversal, and short circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop-powered by 6.2 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.05% of span.\u003c\/li\u003e\n\u003cli\u003eSelectable internal \/ external CJC.\u003c\/li\u003e\n\u003cli\u003e60 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe PR 3337 meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.5 kVAC.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for safe areas and featuring certification for Zone 2 \/ Division 2 and marine applications, the 3337 ensures reliable performance across industrial, energy, wastewater, and chemical process environments. The 3337 delivers accurate temperature conversion with modern HART communication support.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.\u003c\/li\u003e\n\u003cli\u003eSelectable HART mode with HART 7 revision protocol enables extended device programming.\u003c\/li\u003e\n\u003cli\u003eSelectable HART-mode to enable full HART read-write capability.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas.jpg?v=1768941910\" alt=\"PR-3337-HART-Temperature-Converter-PR-electronics-temp-conversion-module-signal-converter-process-solutions-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367715459,"sku":"3337","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3337-HART-temperature-converter-pr-electronics-temp-conversion-signal-process-solutions-corp-psc-texas.jpg?v=1768941929"},{"product_id":"pr-5131-2-wire-temperature-transmitter","title":"PR 5131 2-wire Temperature Transmitter","description":"\u003cp\u003eThe PR 5131 2‑wire Programmable Transmitter is a versatile industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and reliable process control. Featuring universal inputs for RTD, thermocouple (TC), mV, linear resistance, current (mA), and voltage (V), the 5131 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers flexible integration across a wide range of sensing applications. This 2-wire temperature transmitter converts sensor inputs into a standardized 4-20 mA loop output, thus simplifying connection to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS systems, and analog input modules for streamlined industrial automation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5131 Series can configure with the software program PReset using a standard PC and the PR 5909 Loop Link communications unit.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5131A 2-wire Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5100\/2-wire-programmable-transmitter-5131a\/\" target=\"_blank\"\u003ePR 5131A\u003c\/a\u003e 2-wire Temperature Transmitter is suitable for Safe Areas.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5131B 2-wire Ex Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/2-wire-programmable-transmitter-5131b\/\" target=\"_blank\"\u003ePR 5131B\u003c\/a\u003e 2-wire Ex Temperature Transmitter is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5131 2-wire Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and safety, the PR 5131 2-wire Temperature Transmitter features 3.75 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e, protecting sensitive control equipment from electrical noise and interference. As a result, the 5131 also enhances system reliability. Its jumper-selectable inputs allow independent channel configuration for temperature or current \/ voltage measurement, thus providing customization for specific process requirements. The transmitter supports automatic cable compensation (3- or 4-wire) and programmable cable resistance for 2-wire setups.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent channel jumper selectable inputs for current \/ voltage or temperature. \u003c\/li\u003e\n\u003cli\u003eCurrent input programmable in range 0-100 mA and voltage inputs in range 0-250 VDC.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation.\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor error detection including \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration is easy using \u003ca title=\"PR electronics PReset Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset software\u003c\/a\u003e and the Loop Link communications interface, thus enabling precision tuning and rapid deployment across facilities. DIN-rail mounting ensures compact installation and efficient use of cabinet space. In addition, programmable sensor error detection, including NAMUR NE43 compliance, delivers improvements in safety and diagnostic feedback. Ideal for temperature monitoring, resistance signal conversion, and process measurement tasks, the PR 5131 2-wire Temperature Transmitter offers dependable performance for demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 2-channel version has full galvanic isolation between the channels.\u003c\/li\u003e\n\u003cli\u003eSeparation of circuits in PELV\/SELV installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas.jpg?v=1769552245\" alt=\"PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5131AA: 1-Channel (Universal Input)","offer_id":46423771054211,"sku":"5131AA","price":372.0,"currency_code":"USD","in_stock":true},{"title":"5131AB: 2-Channel (Universal Input)","offer_id":46423771086979,"sku":"5131AB","price":631.0,"currency_code":"USD","in_stock":true},{"title":"5131B1A: Ex version; 1-Channel - (RTD\/TC\/mV\/R Input)","offer_id":46423771119747,"sku":"5131B1A","price":450.0,"currency_code":"USD","in_stock":true},{"title":"5131B1B: Ex version; 2-Channel - (RTD\/TC\/mV\/R Input)","offer_id":46423771152515,"sku":"5131B1B","price":728.0,"currency_code":"USD","in_stock":true},{"title":"5131B2A: Ex version; 1-Channel - (mA\/V\/mV Input)","offer_id":46423771185283,"sku":"5131B2A","price":408.0,"currency_code":"USD","in_stock":true},{"title":"5131B2B: Ex version; 2-Channel - (mA\/V\/mV Input)","offer_id":46423771218051,"sku":"5131B2B","price":678.0,"currency_code":"USD","in_stock":true},{"title":"5131B3B: Ex version; Channel 1 - RTD\/TC\/mV\/R; Channel 2 - mA\/V\/mV","offer_id":46423771250819,"sku":"5131B3B","price":704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-pr5131-temperature-converter-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769552538"},{"product_id":"pr-5331-2-wire-temperature-transmitter","title":"PR 5331 2-wire Temperature Transmitter","description":"\u003cp\u003eThe PR 5331 2-Wire Temperature Transmitter is a precision industrial \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal transmitter\u003c\/a\u003e for accurate temperature measurement and seamless integration into \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eprocess control\u003c\/a\u003e systems. The 5331 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is capable of accepting a wide range of sensor inputs, including RTDs (Pt100-Pt1000, Ni100-Ni1000), thermocouples (types B, E, J, K, L, N, R, S, T, U, W3, W5, LR), linear resistance, as well as millivolt signals. This versatile, programmable, head-mounted \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e converts real-world temperature readings into a standard 4-20 mA analog output for reliable loop-power operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or thermocouple (TC) sensors. \u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eModels in the 5331 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is also suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5331A 2-Wire Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-programmable-transmitter-5331a\/\" target=\"_blank\"\u003ePR 5331A\u003c\/a\u003e is certified for hazardous areas Zone 2 \/ Div. 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5331D 2-Wire Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-programmable-transmitter-5331d\/\" target=\"_blank\"\u003ePR 5331D\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5331 2-wire Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 5331 2-wire Temperature Transmitters features measurement accuracy better than ±0.05 % of the selected range as well as a fast programmable response time of 1–60 s. As a result, the 5331 Series ensures precise and stable temperature readings even in demanding industrial environments. Its 1.5 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e enhances signal integrity by minimizing electrical noise and interference, thus the PR 5331 Series is ideal for use in process automation, manufacturing, and energy monitoring applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5331 Series to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3-, and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe PR 5331 2-wire Temperature Transmitter supports programmable sensor error detection and \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43 upset\/downscale signaling. Thus, the 5331 enables proactive diagnostics and enhances safety in control loops. Compact and flexible, the PR 5331 Series can mount in a DIN form B sensor head or on a DIN rail with optional fittings, simplifying installation across diverse industrial settings.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerfect for DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eModel PR 5331A can also mount on a DIN rail with the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5331-2-wire-temperature-transmitter-pr-electronics-programmable-transmitter-temp-sensor-PR5331-PR5331A-PR5331D-Process-Solutions-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5331-2-wire-temperature-transmitter-pr-electronics-programmable-transmitter-temp-sensor-PR5331-PR5331A-PR5331D-Process-Solutions-PSC-Texas.jpg?v=1769717918\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5331A3B: General Purpose; Zone 2 \/ Div 2","offer_id":46446945534083,"sku":"5331A3B","price":292.0,"currency_code":"USD","in_stock":true},{"title":"5331D3B: Zone 0; 1; 2; 21; 22; M1 \/ Div 1; Div 2","offer_id":46446945566851,"sku":"5331D3B","price":351.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5331-2-wire-Temperature-Transmitter-PR-electronics-programmable-temperature-transmitter-ATEX-FM-approval-CSA-certification-hazardous-area-temp-sensor-process-solutions-corp-psc-tex.jpg?v=1769717939"},{"product_id":"pr-5334-thermocouple-temperature-transmitter","title":"PR 5334 Thermocouple Temperature Transmitter","description":"\u003cp\u003eThe PR 5334 Thermocouple Temperature Transmitter is a precision \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e interface for converting thermocouple (TC) and mV signals into a stable 4-20 mA process output ideal for modern control systems. Built for exceptional accuracy, this loop-powered \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, features programmable sensor error values, high measurement precision, and galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e. Thus, the PR 5334 Series ensures reliable temperature measurement in harsh industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC sensor. \u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to a 4-20 mA signal, optionally linearized according to a defined linearization function.\u003c\/li\u003e\n\u003cli\u003eModels in the 5334 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX and IECEx, and is also suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5334A Thermocouple Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-programmable-transmitter-5334a\/\" target=\"_blank\"\u003ePR 5334A\u003c\/a\u003e is certified for hazardous areas Zone 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5334B Thermocouple Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-programmable-transmitter-5334b\/\" target=\"_blank\"\u003ePR 5334B\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5334 Thermocouple Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing fast and flexible configuration, the PR 5334 Thermocouple Temperature Transmitter can program within seconds to measure any TC range within industry standards. Integrated cold junction compensation (CJC) and constant safety checking of stored data enhance measurement reliability for critical applications. The 5334 Series supports DIN form B sensor head mounting and model 5334A offers an optional DIN rail installation with fitting type PR 8421 for even more mounting versatility.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5334 Series to measure temperatures within all TC ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJC) with a built-in temperature sensor.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe PR 5334 thermocouple temperature transmitter offers an operating temperature range from -40 to 185˚F (-40 to 85˚C) in addition to IP68 protection. Furthermore, this temperature transmitter is ideal for HVAC systems, energy-management processes, manufacturing, and automation environments where accurate temperature data is essential for performance and safety. Galvanic isolation and robust EMC immunity make the 5334 Series a dependable choice for industrial temperature conversion and loop integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC\u003c\/a\u003e, DCS, or SCADA systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eModel 5334A also supports DIN rail mounting with the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5334-Thermocouple-Temperature-Transmitter-PR-electronics-PR5334-5334A-5334B-signal-isolation-temperature-converter-industrial-automation-process-solutions-corp-psc-texas.jpg?v=1769787588\" alt=\"PR-5334-Thermocouple-Temperature-Transmitter-PR-electronics-PR5334-5334A-5334B-signal-isolation-temperature-converter-industrial-automation-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5334A3B: General Purpose; Zone 2","offer_id":46450068684931,"sku":"5334A3B","price":172.0,"currency_code":"USD","in_stock":true},{"title":"5334B3B: Zone 0; 1; 2; 21; 22; M1","offer_id":46450068717699,"sku":"5334B3B","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5334-Thermocouple-Temperature-Transmitter-PR-electronics-Isolated-Temperature-Converter-Signal-Isolation-Process-Solutions-PSC-Texas.jpg?v=1769789076"},{"product_id":"pr-5334b-thermocouple-ex-temperature-transmitter","title":"PR 5334B Thermocouple Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 5334B Thermocouple Ex Temperature Transmitter is a precision \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e interface for converting thermocouple (TC) and mV signals into a stable 4-20 mA process output ideal for modern control systems. Built for exceptional accuracy, this loop-powered \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-programmable-transmitter-5334b\/\" title=\"PR electronics 5334B Thermocouple Ex Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, features programmable sensor error values, high measurement precision, and galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e. Thus, the PR 5334B ensures reliable temperature measurement in harsh industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC sensor. \u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to a 4-20 mA signal, optionally linearized according to a defined linearization function.\u003c\/li\u003e\n\u003cli\u003eThe 5334B is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features multiple, different certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX and IECEx, and is also suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePR 5334B also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5334B Thermocouple Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing fast and flexible configuration, the PR 5334B Thermocouple Ex Temperature Transmitter can program within seconds to measure any TC range within industry standards. Integrated cold junction compensation (CJC) and constant safety checking of stored data enhance measurement reliability for critical applications. The 5334B supports DIN form B sensor head mounting.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5334B to measure temperatures within all TC ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJC) with a built-in temperature sensor.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe PR 5334B Thermocouple Ex Temperature Transmitter offers an operating temperature range from -40 to 185˚F (-40 to 85˚C) in addition to IP68 protection. Furthermore, this temperature transmitter is ideal for HVAC systems, energy-management processes, manufacturing, and automation environments where accurate temperature data is essential for performance and safety. Galvanic isolation and robust EMC immunity make the 5334B a dependable choice for industrial temperature conversion and loop integration with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLC\u003c\/a\u003e, DCS, or SCADA systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor DIN form B sensor head mounting.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5334-Thermocouple-Temperature-Transmitter-PR-electronics-PR5334-5334A-5334B-signal-isolation-temperature-converter-industrial-automation-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5334-Thermocouple-Temperature-Transmitter-PR-electronics-PR5334-5334A-5334B-signal-isolation-temperature-converter-industrial-automation-process-solutions-corp-psc-texas.jpg?v=1769787588\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367977603,"sku":"5334B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5334-B-Thermocouple-Temperature-Transmitter-PR-electronics-industrial-temperature-measurement-for-TC-process-solutions-corp-psc-texas.jpg?v=1769789076"},{"product_id":"pr-5335-hart-temperature-transmitter","title":"PR 5335 HART Temperature Transmitter","description":"\u003cp\u003eThe PR 5335 HART Temperature Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate process monitoring and advanced communication. The 5335, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is compatible with RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), ohmic, and mV inputs. Furthermore, this versatile \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e linearizes temperature signals and outputs a reliable 4-20 mA signal with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART 5 communication protocol\u003c\/a\u003e for flexible diagnostics and device configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or thermocouple (TC) sensor.\u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 transmitters to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eModels in the 5335 Series are galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5335a\/\" title=\"PR electronics 5335A HART Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR 5335A\u003c\/a\u003e is certified for hazardous areas Zone 2 \/ Div 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5335d\/\" title=\"PR electronics 5335D HART Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR 5335D\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5335 HART Temperature Transmitter for Thermocouple from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for modern industrial environments, the PR 5335 HART Temperature Transmitter offers extremely high measurement accuracy and programmable sensor error values. In addition, this head-mounted temperature transmitter performs continuous safety checks that improve reliability in demanding applications. With HART capability, users can connect up to 15 transmitters on a single digital 2-wire signal. Thus, the PR 5335 enables remote calibration, real-time diagnostics, and enhances process control without interrupting the analog signal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5335 Series to measure temperatures within all ranges defined by the norms. \u003c\/li\u003e\n\u003cli\u003eThe RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe 5335 Series provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for DIN form B sensor head mounting, this loop-powered transmitter is ideal for HVAC, energy, automation, and manufacturing systems where dependable temperature measurement is essential. The 5335 Series also provides the necessary failure data for SIL 2 applications per IEC 61508\/61511 and sensor error detection per NAMUR standards. Whether upgrading existing installations or specifying new industrial instrumentation, the PR 5335 Series delivers accurate, configurable, and communication-ready temperature measurement for today’s process systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head.\u003c\/li\u003e\n\u003cli\u003eModel 5335A is also suitable for DIN rail mounting with the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas.jpg?v=1769794810\" alt=\"PR-5335-HART-Temperature-Transmitter-PR-electronics-PR5335-5335A-5335D-HART-protocol-industrial-temperature-sensor-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5335A: General Purpose; Zone 2 \/ Div 2; ATEX; CSA; IECEx","offer_id":46450704973955,"sku":"5335A","price":488.0,"currency_code":"USD","in_stock":true},{"title":"5335D: Zone 0; 1; 2; 21; 22; M1 \/ Div 1; Div 2; ATEX; CSA; FM: IECEx","offer_id":46450705006723,"sku":"5335D","price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5335-A-HART-Temperature-Transmitter-PR-electronics-temperature-sensor-for-thermocouple-RTD-mV-input-4-20-ma-signal-conditioner-process-solutions-psc-texas.jpg?v=1769795265"},{"product_id":"pr-5337-hart-5-7-temperature-transmitter","title":"PR 5337 HART 5\/7 Temperature Transmitter","description":"\u003cp\u003eThe PR 5337 HART 5\/7 Temperature Transmitter delivers precise, reliable temperature measurement in addition to advanced communication for demanding industrial applications. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART-enabled\u003c\/a\u003e transmitter supports a wide range of inputs, for example, RTD (Pt100, Ni100), thermocouple (TC), ohm, and bipolar mV signals. The 5337, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, converts linear process values into a stable 4-20 mA output with digital diagnostics. Perfect for modern \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e systems, the PR 5337 HART 5\/7 Temperature Transmitter allows users to select between HART 5 or HART 7 protocol. It enables up to 63 transmitters in a multidrop network with extended tag names, enhanced burst mode, trend logs, as well as event notifications for richer process insights.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature measurement\u003c\/a\u003e with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eModels in the 5337 Series are galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5337A HART 5\/7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337a\/\" target=\"_blank\"\u003ePR 5337A\u003c\/a\u003e is certified for hazardous areas Zone 2 \/ Div 2.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 5337D HART 5\/7 Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337d\/\" target=\"_blank\"\u003ePR 5337D\u003c\/a\u003e also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5337 HART 5\/7 Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThis rugged transmitter is suitable for use in general purpose or hazardous location installations and meets safety and performance standards including SIL-capable hardware and \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e EMC recommendations. Ideal for HVAC, energy, automation, manufacturing, and process industries, the PR 5337 HART 5\/7 Temperature Transmitter supports linearized temperature measurement, differential, or average readings from dual sensors, as well as conversion of resistance or mV signals to standard analog.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers can change the HART protocol revision configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe 5337 HART 5\/7 temperature transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 5337 Series HART transmitter ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eAdditionally, the PR 5337 meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eMountable in a DIN form B sensor head, the PR 5337 HART 5\/7 Temperature Transmitter also features continuous data integrity checks and flexible configuration via HART tools or PR Loop Link interfaces. The PR 5337 Series enhances control system performance with accurate measurement, robust communications, and seamless integration into modern industrial infrastructure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel PR 5337A is also suitable for DIN rail mounting via the fitting type PR 8421.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas.jpg?v=1769804950\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5337A: General Purpose; Zone 2 \/ Div 2; ATEX; CSA; IECEx","offer_id":46450805211267,"sku":"5337A","price":539.0,"currency_code":"USD","in_stock":true},{"title":"5337D: Zone 0; 1; 2; 21; 22; M1 \/ Div 1; Div 2; ATEX; CSA; FM; IECEx","offer_id":46450805244035,"sku":"5337D","price":593.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-A-HART-Temperature-Transmitter-PR-electronics-industrial-temperature-measurement-hart-protocol-process-solutions-texas.jpg?v=1769805616"},{"product_id":"pr-5337d-hart-5-7-ex-temperature-transmitter","title":"PR 5337D HART 5\/7 Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 5337D HART 5\/7 Ex Temperature Transmitter delivers precise, reliable temperature measurement in addition to advanced communication for demanding industrial applications. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART-enabled\u003c\/a\u003e transmitter supports a wide range of inputs, for example, RTD (Pt100, Ni100), thermocouple (TC), ohm, and bipolar mV signals. The 5337D, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/5300\/2-wire-transmitter-with-hart-protocol-5337d\/\" title=\"PR electronics 5337D HART 5\/7 Ex Temperature Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, converts linear process values into a stable 4-20 mA output with digital diagnostics. Perfect for modern \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e systems, the PR 5337D HART 5\/7 Ex Temperature Transmitter allows users to select between HART 5 or HART 7 protocol. It enables up to 63 transmitters in a multidrop network with extended tag names, enhanced burst mode, trend logs, as well as event notifications for richer process insights.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature measurement\u003c\/a\u003e with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eThe 5337D is galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e as well as \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features multiple, different certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, including, ATEX, CSA, and IECEx, and is suitable for use in \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn addition, the 5337D also includes FM certification and is suitable for Zone 0, 1, 2, 21, 22, M1 \/ Div 1, Div 2.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5337D HART 5\/7 Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThis rugged transmitter is suitable for use in general purpose or hazardous location installations and meets safety and performance standards including SIL-capable hardware and \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e EMC recommendations. Ideal for HVAC, energy, automation, manufacturing, and process industries, the PR 5337D HART 5\/7 Ex Temperature Transmitter supports linearized temperature measurement, differential, or average readings from dual sensors, as well as conversion of resistance or mV signals to standard analog.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers can change the HART protocol revision configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe 5337D HART 5\/7 Ex temperature transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the NAMUR NE21 recommendations, the 5337D HART transmitter ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eAdditionally, the PR 5337D meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eMountable in a DIN form B sensor head, the PR 5337D HART 5\/7 Ex Temperature Transmitter also features continuous data integrity checks and flexible configuration via HART tools or PR Loop Link interfaces. The PR 5337D enhances control system performance with accurate measurement, robust communications, and seamless integration into modern industrial infrastructure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for DIN form B sensor head mounting.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003cmeta charset=\"utf-8\"\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-Thermocouple-to-4-20-ma-analog-Temperature-Converter-process-solutions-corp-psc-texas.jpg?v=1769804950\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368108675,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5337-D-HART-5-7-Temperature-Transmitter-PR-electronics-RTD-to-Analog-temperature-measurement-process-solutions-corp-psc-texas.jpg?v=1769805616"},{"product_id":"pr-6331-programmable-temperature-transmitter","title":"PR 6331 Programmable Temperature Transmitter","description":"\u003cp\u003eThe PR 6331 Programmable Temperature Transmitter is a high-precision industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e that converts RTD, thermocouple (TC), linear resistance, or mV signals into a standardized 4-20 mA output for process control systems. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e offers programmable sensor error values, galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e, and exceptionally accurate temperature measurement. Thus, the 6331 Series, from \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for automation environments such as manufacturing, energy, chemical processing, HVAC systems, and more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eModels in the 6331 Series are \u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically isolated, and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6331a\/\" title=\"PR electronics 6331A Programmable Temperature Transmitter\" target=\"_blank\"\u003ePR 6331A\u003c\/a\u003e has certification for mounting in Z\u003cspan\u003eone 2 and 22 \/ Class I, Division 2, Groups A, B, C, D.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6331b\/\" title=\"PR electronics 6331B Programmable Temperature Transmitter\" target=\"_blank\"\u003ePR 6331B\u003c\/a\u003e has certification for mounting in Zone \u003cspan\u003e0, 1, 2, 21, 22, M1 \/ Class I, Division 1, Groups A, B, C, D.\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6331 Programmable Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith support for Pt100-Pt1000, Ni100-Ni1000, and a variety of thermocouples, the PR 6331 Programmable Temperature Transmitter provides reliable, linearized temperature measurement across wide process ranges. Its programmable response time (1-60 s) and cable compensation for 2-, 3-, or 4-wire inputs ensure precise signal conversion even in demanding installations. The transmitter’s galvanic isolation improves noise immunity and also protects connected equipment from electrical interference. Furthermore, programmable output limits and continuous critical data checks enhance system safety and uptime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6331 to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eThe RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for flexible deployment, the PR 6331 Series mounts easily on standard DIN rails and can configure easily using PR Electronics’ Loop Link communication interface. With industry-standard 4-20 mA output and optional \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43 upscale\/downscale signaling, the 6331 integrates seamlessly with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, SCADA, and DCS platforms to support accurate temperature monitoring and control in modern industrial systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, up to 84 channels can mount per meter.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6331-Programmable-Temperature-Transmitter-PR-electronics-PR6331-6331A-6331B-industrial-temperature-measurement-rtd-signal-converter-thermocouple-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6331-Programmable-Temperature-Transmitter-PR-electronics-PR6331-6331A-6331B-industrial-temperature-measurement-rtd-signal-converter-thermocouple-process-solutions-corp-psc-texas.jpg?v=1770152459\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6331A: General Purpose; Zone 2; 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46466932506755,"sku":"6331A2A","price":304.0,"currency_code":"USD","in_stock":true},{"title":"6331A: General Purpose; Zone 2; 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46466932539523,"sku":"6331A2B","price":516.0,"currency_code":"USD","in_stock":true},{"title":"6331B: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 1-Channel","offer_id":46466932572291,"sku":"6331B2A","price":365.0,"currency_code":"USD","in_stock":true},{"title":"6331B: Zone 0; 1; 2; 21; 22; M1 \/ Class I; Div 1; Groups A B C D \/ 2-Channel","offer_id":46466932605059,"sku":"6331B2B","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6331-Programmable-Temperature-Transmitter-PR-electronics-6331B-isolated-signal-converter-for-temperature-measurement-process-solutions-psc-texas.jpg?v=1770153586"},{"product_id":"pr-6331b-2-wire-ex-temperature-transmitter","title":"PR 6331B 2-wire Ex Temperature Transmitter","description":"\u003cp\u003eThe PR 6331B 2-wire Ex Temperature Transmitter is a high-precision industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e that converts RTD, thermocouple (TC), linear resistance, or mV signals into a standardized 4-20 mA output for process control systems. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e offers programmable sensor error values, galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e, and exceptionally accurate temperature measurement. Thus, the 6331B, from \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6331b\/\" title=\"PR electronics 6331B 2-wire Ex Temperature Transmitter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for automation environments such as manufacturing, energy, chemical processing, HVAC systems, and more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eThe 6331B is \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically isolated, and features certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6331b\/\" title=\"PR electronics 6331B Programmable Temperature Transmitter\" target=\"_blank\"\u003ePR 6331B\u003c\/a\u003e has certification for mounting in Zone \u003cspan\u003e0, 1, 2, 21, 22, M1 \/ Class I, Division 1, Groups A, B, C, D.\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6331B 2-wire Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith support for Pt100-Pt1000, Ni100-Ni1000, and a variety of thermocouples, the PR 6331B 2-wire Ex Temperature Transmitter provides reliable, linearized temperature measurement across wide process ranges. Its programmable response time (1-60 s) and cable compensation for 2-, 3-, or 4-wire inputs ensure precise signal conversion even in demanding installations. The transmitter’s galvanic isolation improves noise immunity and also protects connected equipment from electrical interference. Furthermore, programmable output limits and continuous critical data checks enhance system safety and uptime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6331B to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eThe RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for flexible deployment, the PR 6331B mounts easily on standard DIN rails and can configure easily using PR Electronics’ Loop Link communication interface. With industry-standard 4-20 mA output and optional \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43 upscale\/downscale signaling, the 6331B integrates seamlessly with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, SCADA, and DCS platforms to support accurate temperature monitoring and control in modern industrial systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, up to 84 channels can mount per meter.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6331-Programmable-Temperature-Transmitter-PR-electronics-PR6331-6331A-6331B-industrial-temperature-measurement-rtd-signal-converter-thermocouple-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6331-Programmable-Temperature-Transmitter-PR-electronics-PR6331-6331A-6331B-industrial-temperature-measurement-rtd-signal-converter-thermocouple-process-solutions-corp-psc-texas.jpg?v=1770152459\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368272515,"sku":"6331B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6331-Programmable-Temperature-Transmitter-PR-electronics-6331B-2-wire-temp-measurement-for-RTD-Thermocouple-Process-Solutions-PSC-Texas.jpg?v=1770153586"},{"product_id":"pr-6334-thermocouple-temperature-transmitter","title":"PR 6334 Thermocouple Temperature Transmitter","description":"\u003cp\u003eThe PR 6334 Thermocouple Temperature Transmitter is an advanced industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for high-accuracy thermocouple (TC) and mV signal measurement in modern process control and automation systems. This programmable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e converts thermocouple or bipolar mV inputs into a standardized 4-20 mA output. Thus, the 6334 Series, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ensures reliable integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA platforms for precise temperature monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC sensor.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to a 4-20 mA signal, optionally linearized according to a defined linearization function.\u003c\/li\u003e\n\u003cli\u003eModels in the 6334 Series are \u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6334a\/\" title=\"PR electronics 6334A Thermocouple Temperature Transmitter\" target=\"_blank\"\u003ePR 6334A\u003c\/a\u003e has certification for mounting in Zone 2 and 22.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6334b\/\" title=\"PR electronics 6334B Ex Thermocouple Temperature Transmitter\" target=\"_blank\"\u003ePR 6334B\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6334 Thermocouple Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing built-in cold junction compensation (CJC) and galvanic isolation, the PR 6334  Thermocouple Temperature Transmitter delivers exceptional signal integrity while minimizing electrical interference in harsh industrial environments. Users can quickly program temperature ranges, output limits, as well as sensor error values using the PR Loop Link communications interface. As a result, the 6334 Series optimizes performance and enhances diagnostics for safer operation. This transmitter supports both single-channel and 2-channel configurations, allowing up to 84 channels per meter on a DIN rail, thus making the PR 6334 Series ideal for compact installations with high channel density. The 6334 Series fast programmable response times (1-60s), high signal-to-noise ratio, and continuous EEPROM data checks ensure dependable performance and also reduce downtime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6334 Series to measure temperatures within all thermocouple ranges defined by the norms. \u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJC) with a built-in temperature sensor.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eWith various certifications for use in hazardous areas, the PR 6334 Thermocouple Temperature Transmitter safely operates in demanding industrial temperature measurement applications. For example, the 6334 is ideal for manufacturing, energy, chemical processing, and industrial automation. Its robust design, extensive programming options, and industry-standard output make it a top choice for accurate, long-term temperature \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6334-Thermocouple-Temperature-Transmitter-PR-electronics-PR6334-6334A-6334B-2-wire-Programmable-Transmitter-Industrial-Temperature-Sensor-Signal-Converter-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6334-Thermocouple-Temperature-Transmitter-PR-electronics-PR6334-6334A-6334B-2-wire-Programmable-Transmitter-Industrial-Temperature-Sensor-Signal-Converter-Process-Solutions-Corp-PS.jpg?v=1770222305\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6334A: General Purpose; Zone 2 and 22 \/ 1-Channel","offer_id":46470220415107,"sku":"6334A1A","price":232.0,"currency_code":"USD","in_stock":true},{"title":"6334A: General Purpose; Zone 2 and 22 \/ 2-Channel","offer_id":46470220447875,"sku":"6334A1B","price":398.0,"currency_code":"USD","in_stock":true},{"title":"6334B: Zone 0; 1; 2; 21; 22; M1 \/ 1-Channel","offer_id":46470220480643,"sku":"6334B1A","price":274.0,"currency_code":"USD","in_stock":true},{"title":"6334B: Zone 0; 1; 2; 21; 22; M1 \/ 2-Channel","offer_id":46470220513411,"sku":"6334B1B","price":460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6334-Thermocouple-Temperature-Transmitter-PR-electronics-6334A-Industrial-Temperature-Measurement-TC-Process-Solutions-Corp-PSC-Texas.jpg?v=1770222961"},{"product_id":"pr-6334b-ex-thermocouple-temperature-transmitter","title":"PR 6334B Ex Thermocouple Temperature Transmitter","description":"\u003cp\u003eThe PR 6334B Ex Thermocouple Temperature Transmitter is an advanced industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for high-accuracy thermocouple (TC) and mV signal measurement in modern process control and automation systems. This programmable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e converts thermocouple or bipolar mV inputs into a standardized 4-20 mA output. Thus, the 6334B, from \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-programmable-transmitter-6334b\/\" title=\"PR electronics 6334B Ex Thermocouple Temperature Transmitter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ensures reliable integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA platforms for precise temperature monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC sensor.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to a 4-20 mA signal, optionally linearized according to a defined linearization function.\u003c\/li\u003e\n\u003cli\u003eThe 6334B is \u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, and features certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003ePR 6334B has certification for mounting in Zone 0, 1, 2, 21, 22, M1.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6334B Ex Thermocouple Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing built-in cold junction compensation (CJC) and galvanic isolation, the PR 6334B Ex  Thermocouple Temperature Transmitter delivers exceptional signal integrity while minimizing electrical interference in harsh industrial environments. Users can quickly program temperature ranges, output limits, as well as sensor error values using the PR Loop Link communications interface. As a result, the 6334B optimizes performance and enhances diagnostics for safer operation. This transmitter supports both single-channel and 2-channel configurations, allowing up to 84 channels per meter on a DIN rail, thus making the PR 6334B ideal for compact installations with high channel density. The 6334B fast programmable response times (1-60s), high signal-to-noise ratio, and continuous EEPROM data checks ensure dependable performance and also reduce downtime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6334B to measure temperatures within all thermocouple ranges defined by the norms. \u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJC) with a built-in temperature sensor.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eWith various certifications for use in hazardous areas, the PR 6334B Ex Thermocouple Temperature Transmitter safely operates in demanding industrial temperature measurement applications. For example, the 6334B is ideal for manufacturing, energy, chemical processing, and industrial automation. Its robust design, extensive programming options, and industry-standard output make it a top choice for accurate, long-term temperature \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6334-Thermocouple-Temperature-Transmitter-PR-electronics-PR6334-6334A-6334B-2-wire-Programmable-Transmitter-Industrial-Temperature-Sensor-Signal-Converter-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6334-Thermocouple-Temperature-Transmitter-PR-electronics-PR6334-6334A-6334B-2-wire-Programmable-Transmitter-Industrial-Temperature-Sensor-Signal-Converter-Process-Solutions-Corp-PS.jpg?v=1770222305\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368403587,"sku":"6334B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6334B-Thermocouple-Ex-Temperature-Transmitter-Signal-Isolation-Temperature-Sensor-Signal-Converter-Process-Solutions-PSC-Texas.jpg?v=1770222961"},{"product_id":"pr-6335-2-wire-hart-transmitter","title":"PR 6335 2-wire HART Transmitter","description":"\u003cp\u003eThe PR 6335 2-wire HART Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precise temperature and resistance \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in advanced process automation systems. The 6335 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), linear resistance, as well as mV inputs. Furthermore, this versatile transmitter converts sensor signals into a standardized 4-20 mA output with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication for efficient monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, as well as TC sensors. \u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance (RTD) or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 channels to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eModels in the 6335 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335A 2-wire HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335a\/\" target=\"_blank\"\u003ePR 6335A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335D 2-wire Ex HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335d\/\" target=\"_blank\"\u003ePR 6335D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6335 2-wire HART Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6335 offers HART 5 protocol support and galvanic isolation between input and output. Furthermore, the 6335 2-wire HART Transmitter delivers robust signal integrity and reliable data transmission even in electrically noisy industrial environments. This transmitter offers programmable response time (1-60s), sensor error detection compliance with \u003ca title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89, and cable compensation for 2-, 3-, or 4-wire configurations. Thus, the PR 6335 Series ensures accurate measurements with minimal wiring impact. With better than 0.05% accuracy of the selected range and support for differential or average temperature measurement, the 6335 Series fits a broad range of industrial applications including manufacturing, energy, chemical processing, HVAC, and automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6335 Series to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe PR 6335 2-wire HART Transmitter provides the necessary failure data (SFF and PFDAVG) for SIL applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in NAMUR NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple and use standard HART interfaces or the PR Loop Link communication tool. Thus, the PR 6335 2-wire HART Transmitter enables remote parameterization and real-time device insights for improving maintenance and uptime. With certification for installations in hazardous areas, this transmitter combines accuracy, connectivity, and durability for demanding industrial temperature measurement needs. \u003cmeta charset=\"utf-8\"\u003eInstallation is flexible, mountable vertically or horizontally on standard DIN rails with up to 84 channels per meter for high-density panel layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, users can mount up to 84 channels per meter. \u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225929\" alt=\"PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46470501695619,"sku":"6335A2A","price":514.0,"currency_code":"USD","in_stock":true},{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46470501728387,"sku":"6335A2B","price":917.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 1-Channel","offer_id":46470501761155,"sku":"6335D2A","price":561.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 2-Channel","offer_id":46470501793923,"sku":"6335D2B","price":1001.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-signal-isolation-temperature-transmitter-rtd-thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225948"},{"product_id":"pr-6335d-2-wire-hart-ex-transmitter","title":"PR 6335D 2-wire HART Ex Transmitter","description":"\u003cp\u003eThe PR 6335D 2-wire HART Ex Transmitter is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e for precise temperature and resistance \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal conversion\u003c\/a\u003e in advanced process automation systems. The 6335D, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335d\/\" title=\"PR electronics 6335D 2-wire HART Ex Transmitter\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, supports RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), linear resistance, as well as mV inputs. Furthermore, this versatile transmitter converts sensor signals into a standardized 4-20 mA output with integrated \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e communication for efficient monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, as well as TC sensors. \u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance (RTD) or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca title=\"Level Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 channels to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eThe 6335D is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e, and features certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePR 6335D has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6335D 2-wire HART Ex Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6335D offers HART 5 protocol support and galvanic isolation between input and output. Furthermore, the 6335D 2-wire HART Ex Transmitter delivers robust signal integrity and reliable data transmission even in electrically noisy industrial environments. This transmitter offers programmable response time (1-60s), sensor error detection compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89, and cable compensation for 2-, 3-, or 4-wire configurations. Thus, the PR 6335D ensures accurate measurements with minimal wiring impact. With better than 0.05% accuracy of the selected range and support for differential or average temperature measurement, the 6335D fits a broad range of industrial applications including manufacturing, energy, chemical processing, HVAC, and automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6335D to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe PR 6335D 2-wire HART Ex Transmitter provides the necessary failure data (SFF and PFDAVG) for SIL applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in NAMUR NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple and use standard HART interfaces or the PR Loop Link communication tool. Thus, the PR 6335D 2-wire HART Ex Transmitter enables remote parameterization and real-time device insights for improving maintenance and uptime. With certification for installations in hazardous areas, this transmitter combines accuracy, connectivity, and durability for demanding industrial temperature measurement needs. \u003cmeta charset=\"utf-8\"\u003eInstallation is flexible, mountable vertically or horizontally on standard DIN rails with up to 84 channels per meter for high-density panel layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, users can mount up to 84 channels per meter. \u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225929\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368469123,"sku":"6335D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-D-2-wire-Ex-HART-Transmitter-PR-electronics-intrinsically-safe-temperature-transmitter-signal-isolation-Process-Solutions-PSC-Texas.jpg?v=1770226650"},{"product_id":"pr-9113-ma-temperature-converter","title":"PR 9113 mA Temperature Converter","description":"\u003cp\u003eThe PR 9113 mA Temperature Converter is a high-precision temperature to current \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e for demanding industrial and process-automation environments. The 9113 Series is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca title=\"PR electronics 4500 Series Programming Interface\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9113A mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/9100\/temperature-ma-converter-9113a\/\" target=\"_blank\"\u003ePR 9113A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver.\u003c\/li\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910, channel 1 \/ PR 5913, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9113B Ex mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" target=\"_blank\"\u003ePR 9113B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113 mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113 mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 Series includes 2.6 kVAC galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113 mA Temperature Converter has certification for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113 Series is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113 mA Temperature Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113 Series can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas.jpg?v=1770408025\" alt=\"PR-9113-mA-Temperature-Transmitter-PR-electronics-PR9113-9113A-9113B-Temp-Signal-Isolator-Intrinsically-Safe-ATEX-SIL-temperature-sensor-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel \/ None - Standard","offer_id":45878368698499,"sku":"9113AA","price":428.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501312131,"sku":"9113AA-U9","price":438.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel \/ None - Standard","offer_id":46499924476035,"sku":"9113AB","price":650.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501344899,"sku":"9113AB-U9","price":659.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel \/ None - Standard","offer_id":46499924574339,"sku":"9113BA","price":453.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501377667,"sku":"9113BA-U9","price":465.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel \/ None - Standard","offer_id":46499924607107,"sku":"9113BB","price":676.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel \/ -U9: U9\/UL193 Approval","offer_id":46575501410435,"sku":"9113BB-U9","price":686.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-mA-Temperature-Converter-PR-electronics-IS-hazardous-area-temperature-transmitter-intrinsic-safety-RTD-thermocouple-Process-Solutions-PSC-Texas.jpg?v=1770408686"},{"product_id":"pr-9113-emp-ma-temperature-converter-with-emphasis-assessment","title":"PR 9113-EMP mA Temperature Converter with EMPHASIS Assessment","description":"\u003cp\u003eThe PR 9113-EMP mA Temperature Converter is a high-precision temperature to current \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e with EMPHASIS assessment for the nuclear industry. The 9113-EMP is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113-EMP Series, from \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/9100\/temperature-ma-converter-9113a-emp\/\" title=\"PR electronics 9113A-EMP mA Temperature Converter with EMPHASIS Assessment\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interface\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" title=\"PR electronics 9113B Ex mA Temperature Converter\" target=\"_blank\"\u003e\u003c\/a\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eFeatures EMPHASIS assessment and mounts in \u003cmeta charset=\"utf-8\"\u003eZone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113-EMP mA Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113-EMP mA Temperature Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 includes 2.6 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113-EMP Temperature \/ mA Converter has certification for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113-EMP is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113-EMP Temperature \/ mA Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113-EMP can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648896\" alt=\"PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ A: 1-Channel","offer_id":46575406710915,"sku":"9113AA-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ B: 2-Channel","offer_id":46575406743683,"sku":"9113AB-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ A: 1-Channel","offer_id":46575406776451,"sku":"9113BA-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9113B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ B: 2-Channel","offer_id":46575406809219,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-temperature-to-current-signal-converter-EMPHASIS-Assessment-Nuclear-Power-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648923"},{"product_id":"pr-9106b-ex-hart-transparent-repeater","title":"PR 9106B Ex HART Transparent Repeater","description":"\u003cp\u003eThe PR 9106B Ex HART Transparent Repeater is a high-performance signal repeater for industrial automation and process control applications where reliable, accurate communication is critical. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device delivers robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (2.6 kVAC) to protect sensitive instrumentation from electrical interference. As a result, the 9106B, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-repeater-9106b\/\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, ensures consistent signal integrity, even in harsh environments. With support for active as well as passive mA inputs and outputs, the PR 9106B Ex HART Transparent Repeater seamlessly interfaces with 2-wire SMART transmitters and current sources while enabling bi-directional \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9106B is a 1- or 2-channel isolated 1:1 repeater barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eThe 9106B supplies 2-wire SMART transmitters and is also suitable for use as a 2-wire SMART current source.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater supports both \u003ca href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" title=\"HART Protocol\" rel=\"noopener\" target=\"_blank\"\u003eHART\u003c\/a\u003e \u0026amp; BRAIN protocols and can transfer bi-directionally.\u003c\/li\u003e\n\u003cli\u003eFor duplication\/migration purposes, outputs can send to two different DCS,  \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLC\/HMI\u003c\/a\u003e, or any monitoring system. \u003c\/li\u003e\n\u003cli\u003eModels in the 9106B are galvanically isolated, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eThe PR 9106B can mount in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003eIn safety applications (SIL loops), model 9106BxBx is suitable for use as a splitter with the following output configuration:\n\u003cul\u003e\n\u003cli\u003eWhen using 9106BxBx in a SIL2 safety function, channel 1 is the safety loop.\u003c\/li\u003e\n\u003cli\u003eChannel 2 is suitable for any non-safety device.\u003c\/li\u003e\n\u003cli\u003eFor higher safety purposes (SIL 3), 9106BxBx can function as a splitter for SIL 3 loops.\u003c\/li\u003e\n\u003cli\u003eChannel 1 and 2 then connect to the same safety PLC, where channel 2 is a redundant diagnostic channel (for more information, consult the FMEDA Report and the Safety Manual).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9106B Ex HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing wide flexibility, the PR 9106B Ex HART Transparent Repeater can operate as a single-channel or dual-channel repeater. Furthermore, the 9106B includes a splitter function to duplicate a single input to two outputs, which is ideal for feeding multiple DCS, PLC, or HMI systems without signal degradation. Its fast response time (-5 ms) and high accuracy (better than ±0.1%) ensure real-time monitoring performance. Some models of the PR 9106B feature certification for use in SIL2\/SIL3 safety loops according to \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 and is suitable for safety-critical installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe detachable displays in the \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500 series\u003c\/a\u003e and the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage on input via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9106B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eFast response time \u0026lt;5 ms.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003e2-wire transmitter supply \u0026gt;16 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe 9016 Series is compact, DIN-rail mountable, and compatible with optional detachable displays and status monitoring accessories. Furthermore, the PR 9106B Ex HART Transparent Repeater is an ideal choice for enhancing HART signal reliability and expanding system integration with minimal configuration effort.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePR 9106B devices can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-HART-Transparent-Repeater-PR-electronics-PR9106-9106A-9106B-HART-Signal-Splitter-Repeater-Signal-Transmitter-HART-Protocol-Signal-Isolator-for-Hazardous-Areas-Process-Solution.jpg?v=1770394665\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368764035,"sku":"9106B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9106-B-HART-Ex-Transparent-Repeater-PR-electronics-HART-Signal-Splitter-Repeater-Intrinsically-Safe-Barrier-Signal-Isolator-Process-Solutions-PSC-Texas.jpg?v=1770396175"},{"product_id":"pr-9107b-hart-ex-transparent-driver","title":"PR 9107B HART Ex Transparent Driver","description":"\u003cp\u003eThe PR 9107B HART Ex Transparent Driver is a high-performance industrial signal driver for precise control and reliable communication in process automation systems. The 9107B, from \u003ca title=\"PR electronics 9107B HART Ex Transparent Driver\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/hart-transparent-driver-9107b\/\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is suitable for both single-channel and dual-channel applications. Furthermore, the PR 9107B delivers galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e 1:1 current driving capability, making it ideal for powering and controlling I\/P converters, \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e, and indicators in safe or \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e. Its bi-directional \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e transparency ensures seamless communication with HART-enabled field devices, thus allowing real-time diagnostics, configuration, and monitoring without signal loss or interference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperation and drive control of I\/P converters, valves, and indicators.\u003c\/li\u003e\n\u003cli\u003eOperation of \u003ca rel=\"noopener\" title=\"HART Protocol\" href=\"https:\/\/www.fieldcommgroup.org\/technologies\/hart\" target=\"_blank\"\u003eHART\u003c\/a\u003e devices is possible as the unit transmits HART communication signals bi-directionally.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e Series displays the process value for each channel and can also define high and low limits for detection of loop current level. If these limits are exceeded, the status relay will activate.\u003c\/li\u003e\n\u003cli\u003eDual channel versions can operate in signal splitter applications - 1 in and 2 out.\u003c\/li\u003e\n\u003cli\u003eThe 9107B is galvanically isolated, \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, and features various certifications for use in hazardous areas as well as \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9107B HART Ex Transparent Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9107B HART Ex Transparent Driver features fast response times (\u0026lt; 5 ms), high load drive (725 Ω at 20 mA), and robust output line fault detection via status relay. Furthermore, the 9107B ensures dependable performance under industrial conditions. SIL 2 certification per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 attests to its suitability in safety-related systems where functional reliability is critical.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 4500 detachable displays as well as the green and red front LEDs indicate operation status for each channel.\u003c\/li\u003e\n\u003cli\u003eA tag number can be defined for each channel.\u003c\/li\u003e\n\u003cli\u003eOutput line fault detection.\u003c\/li\u003e\n\u003cli\u003eIn the 1-channel version the status relay can be used as a simple limit switch.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 9107B correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003eHigh galvanic isolation of 2.6 kVAC.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy better than 0.1%.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFor added flexibility, a detachable PR 4500 display provides local process value indication and configurable loop current limits with alarm output. Dual-channel versions support splitter functionality, delivering a single input to two outputs for expanded system integration. Compact and DIN-rail mountable, the PR 9107B HART Ex Transparent Driver blends safety, precision, and versatility. Thus, the 9107B optimizes control system architecture while enhancing operational uptime and HART communication continuity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 9107B can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-HART-Transparent-Driver-PR-electronics-PR9107-9107A-9107B-HART-Protocol-Signal-Splitter-Intrinsically-Safe-Barrier-Signal-Isolator-Hazardous-Area-Transmitter-Process-Solutions.jpg?v=1770400499\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368796803,"sku":"9107B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9107-Ex-HART-Transparent-Driver-PR-electronics-9107N-HART-Signal-Splitter-Isolated-Signal-Driver-Intrinsically-Safe-Process-Solutions-Corp-PSC-Texas.jpg?v=1770404383"},{"product_id":"pr-9113b-emp-temperature-ma-converter","title":"PR 9113B-EMP Temperature \/ mA Converter with EMPHASIS Assessment","description":"\u003cp\u003eThe PR 9113B-EMP Temperature \/ mA Converter is a high-precision temperature to current \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e with EMPHASIS assessment for the nuclear industry. The 9113B-EMP is capable of accepting RTD, thermocouple (TC), and mA inputs. It provides accurate scaling and conversion to an active or passive 4-20 mA output via the same two terminals, thus simplifying wiring and enhancing signal reliability. The 9113B-EMP, from \u003ca title=\"PR electronics 9113B-EMP Temperature \/ mA Converter with EMPHASIS Assessment\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports one or two channels and can also be powered independently or mounted on a PR type 9400 power rail. As a result, this mA temperature converter offers vast installation flexibility for control panels and distributed systems alike.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable \u003ca title=\"PR electronics 4500 Series Programming Interface\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series display front; process calibration and signal simulation. \u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users can activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eModels in the 9113 are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"PR electronics 9113B Ex mA Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/temperature-ma-converter-9113b\/\" target=\"_blank\"\u003e\u003c\/a\u003e1- or 2-channel isolated 1:1 driver barrier for intrinsic safety applications.\u003c\/li\u003e\n\u003cli\u003eFeatures EMPHASIS assessment and mounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eTC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 \/ PR 5913Ex, channel 2) for higher accuracy.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and robustness, the PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter features programmable response time (1-60s), high-resolution signal conversion, and advanced self-monitoring capabilities. A detachable PR 4500 display enables local configuration, calibration, and signal simulation, thus helping technicians commission and maintain systems efficiently. The 9113 includes 2.6 kVAC galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and also supply to protect sensitive instrumentation from electrical noise and ground loops.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature (Pt, Ni, and TC) as well as active current signals. \u003c\/li\u003e\n\u003cli\u003eThe PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter has certification for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508. \u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9113 correspond to Performance Level \"d\" according to ISO-13849. \u003c\/li\u003e\n\u003cli\u003e1 green and 2 red front LEDs indicate operation status and also malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, as well as supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for use in SIL 2 safety applications per IEC 61508, the 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP is suitable for installation in safe areas as well as various hazardous location. Thus, the PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP Temperature \/ mA Converter supports critical temperature measurement and control loops in manufacturing, energy, chemical, and process industries. Its compact DIN-rail form factor and rugged construction make it a reliable choice for scalable, high-integrity signal conditioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9113\u003cmeta charset=\"utf-8\"\u003eB-EMP can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; margin-bottom: 16px; float: none;\" alt=\"PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113A-EMP-Temperature-mA-Converter-PR-electronics-9113B-EMP-PR9113-EMP-EMPHASIS-Assessment-Nuclear-Industry-Signal-Converter-Temperature-to-Current-Process-Solutions-Corp-PSC-Texas.jpg?v=1770648896\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"A: 1-Channel","offer_id":46575380627587,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"B: 2-Channel","offer_id":46575380660355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9113-B-EMP-Temperature-mA-Converter-PR-electronics-Signal-Converter-with-EMPHASIS-Assessment-for-Thermocouple-RTD-4-20-mA-Output-Process-Solutions-PSC-Texas.jpg?v=1770651975"},{"product_id":"pr-9116b-ex-universal-converter","title":"PR 9116B Ex Universal Converter","description":"\u003cp\u003eThe PR 9116B Ex Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for industrial process control and automation. The 9116B, from \u003ca title=\"PR electronics 9116B Ex Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eThe 9116B is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116B Ex Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116B features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116B Ex Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B Ex Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutio.jpg?v=1770654546\" alt=\"PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"1: Uo 28 VDC","offer_id":46575683928195,"sku":"9116B-1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2: Uo 21.4 VDC","offer_id":46575683960963,"sku":"9116B-2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-B-Ex-Universal-Converter-PR-electronics-9116B-temperature-voltage-resistance-signal-converter-universal-transmitter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770655699"},{"product_id":"pr-9116b-emp-ex-universal-converter-for-nuclear-industry","title":"PR 9116B-EMP Ex Universal Converter for Nuclear Industry","description":"\u003cp\u003eThe PR 9116B-EMP Ex Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device that's EMPHASIS assessed for nuclear applications. The 9116B-EMP, from \u003ca title=\"PR electronics 9116B-EMP Ex Universal Converter with EMPHASIS Assessment\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b-emp\/\" target=\"_blank\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eThe 9116B-EMP is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116B-EMP Ex Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116B-EMP features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116B-EMP Ex Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B-EMP has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116B-EMP correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116B-EMP Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; margin-bottom: 16px; float: none;\" alt=\"PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas.jpg?v=1770658616\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368927875,"sku":"9116B-EMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-B-Ex-Universal-Converter-PR-electronics-Intrinsically-Safe-Signal-Converter-for-Nuclear-Industry-EMPHASIS-Assessed-Hazardous-Area-Signal-Converter-Process-Solutions-Texas.jpg?v=1770659390"},{"product_id":"pr-9202b-ex-pulse-isolator","title":"PR 9202B Ex Pulse Isolator","description":"\u003cp\u003eThe PR 9202B Ex Pulse Isolator is a high-reliability industrial \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003esignal isolation\u003c\/a\u003e solution for interfacing \u003ca rel=\"noopener\" title=\"NAMUR Assocation\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e sensors and mechanical switches with safety-critical control systems. Ideal for robust performance in process automation, this DIN-rail mountable isolator provides advanced self-diagnostics, cable-fault detection and optional SIL 2 certification. Thus, the 9202B, from \u003ca title=\"PR electronics 9202B Ex Pulse Isolator\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9200\/pulse-isolator-9202b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for applications requiring enhanced functional safety and compliance with \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 standards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front: \u003ca title=\"PR electronics 4500 Series Programming Interface\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series. \u003c\/li\u003e\n\u003cli\u003eSelection of direct or inverted function for each channel via PR 4500.\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring of internal communication and storage data.\u003c\/li\u003e\n\u003cli\u003eOptional redundant supply via power rail and\/ or separate supply.\u003c\/li\u003e\n\u003cli\u003eSIL 2 functionality is optional and users must activate it in a menu point.\u003c\/li\u003e\n\u003cli\u003eThe 9202B is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9202B Ex Pulse Isolator from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe 9202B is available with one or two channels and configurable direct or inverted pulse functions via the detachable PR 4500 front display. Furthermore, the PR 9202B Ex Pulse Isolator delivers flexible \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e for a wide range of industrial environments. Its extended status indication, including individual and collective error signaling, allows operators to quickly identify system issues and improve uptime. Optional redundant \u003ca title=\"Power and Supply Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003epower supply\u003c\/a\u003e further increases resiliency in mission-critical installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9202B ex pulse isolator is ideal for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9202B has been designed, developed, and certified for use in SIL 2 applications according to the requirements of IEC 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9202B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe PR 9202B accepts NAMUR input frequencies up to 5 kHz while providing reinforced 2.6 kVAC galvanic isolation between input, output, and power. A compact footprint and wide temperature range ensure seamless integration into automation, energy, oil \u0026amp; gas, and manufacturing systems. Users can depend on the PR 9202B Ex Pulse Isolator for accurate signal transmission, enhancing safety integrity, and providing reliable performance under demanding conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 2 yellow\/red front LEDs indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9202B Ex Pulse Isolator can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-9202-Pulse-Isolator-PR-electronics-Signal-Isolation-Device-for-NAMUR-Sensors-SIL-2-intrinsic-safety-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9202-Pulse-Isolator-PR-electronics-Signal-Isolation-Device-for-NAMUR-Sensors-SIL-2-intrinsic-safety-Process-Solutions-Corp-PSC-Texas.jpg?v=1770661760\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368960643,"sku":"9202B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9202-B-Ex-Pulse-Isolator-PR-electronics-Intrinsically-Safe-Pulse-Isolation-Device-Signal-Isolated-Transmitter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770663370"},{"product_id":"pr-9203b-solenoid-alarm-ex-driver","title":"PR 9203B Solenoid \/ Alarm Ex Driver","description":"\u003cp\u003eThe PR 9203B Solenoid \/ Alarm Ex Driver is a universal industrial driver for dependable control of solenoid valves, acoustic alarms, and LEDs in automation systems. Built for robust performance and functional safety, this DIN-rail mounted driver delivers selectable current outputs (Low 35 mA or High 60 mA). In addition, the 9203B, from \u003ca rel=\"noopener\" title=\"PR electronics 9203 B Solenoid \/ Alarm Ex Driver\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9200\/solenoid-alarm-driver-9203b\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, features advanced self-diagnostics to ensure accurate activation and monitoring of field outputs. With configuration and real-time status monitoring via the detachable \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series display, the 9203B Ex Driver lets technicians choose the direct or inverted channel functions and optionally supervise output current for enhancing process insight.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo hardware versions make it possible to choose either Low (35 mA) or High (60 mA) current output.\u003c\/li\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (PR 4500).\u003c\/li\u003e\n\u003cli\u003eSelection of direct or inverted function for each channel via PR 45xx and also the possibility of reducing the output current to suit the application. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional redundant supply via power rail and\/or separate supply.\u003c\/li\u003e\n\u003cli\u003eThe 9203B is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eUniversal driver for the control of solenoids, alarms, etc. with various intrinsically safe (I.S.) data by way of three built-in I.S. barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eOptional monitoring of the output current to the hazardous area by way of PR 4500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9203B Solenoid \/ Alarm Ex Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9203B offers certification to SIL 2 standards through full assessment (\u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508) and meets Performance Level \"d\" (ISO-13849). As a result, the PR 9203B Ex Driver for solenoids and alarms supports reliability in safety-critical automation applications. The 9203B operates with either NPN\/PNP sensor signals or simple switch control. Furthermore, it includes internal diagnostics with individual status relay feedback. Its reinforced 2.6 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and supply protects sensitive electronics from interference and fault conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 9203B Solenoid \/ Alarm Ex Driver can control the ON \/ OFF function of solenoids, acoustic alarms, and LEDs. \u003c\/li\u003e\n\u003cli\u003eThe PR 9203B Ex Driver for solenoids and alarms is controlled by an NPN\/PNP signal or a switch signal. \u003c\/li\u003e\n\u003cli\u003eMonitoring of internal error events via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe 9203B has been designed, developed, and certified for use in SIL 2 applications according to the requirements of IEC 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 9203B correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eSuitable for installation in safe areas and hazardous environments, the 9203B Ex driver for solenoids and alarms is ideal for oil \u0026amp; gas, energy, water treatment, and general process automation systems that require reliable actuation and safety compliance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 2 yellow\/red front LEDs indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9203B Solenoid \/ Alarm Ex Driver can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 25px; margin-bottom: 16px; float: none;\" alt=\"PR-9203-Driver-for-Solenoids-and-Alarms-PR-electronics-PR9203-9203A-9203B-Isolated-Driver-for-Signal-Conditioning-Signal-Isolation-Industrial-Automation-Control-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9203-Driver-for-Solenoids-and-Alarms-PR-electronics-PR9203-9203A-9203B-Isolated-Driver-for-Signal-Conditioning-Signal-Isolation-Industrial-Automation-Control-Process-Solutions-Corp.jpg?v=1770668014\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878368993411,"sku":"9203B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9203-B-Ex-Solenoid-Alarm-Driver-PR-electronics-Isolated-Solenoid-Driver-Signal-Isolation-Signal-Conditioning-Process-Solutions-PSC-Texas.jpg?v=1770671309"},{"product_id":"pr-5104b-ex-repeater-power-supply","title":"PR 5104B Ex Repeater \/ Power Supply","description":"\u003cp\u003eThe PR 5104B Ex Repeater and Power Supply module is a high-performance industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolated\u003c\/a\u003e repeater and power supply for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e and transmitter loop power applications. Built with universal AC\/DC supply range (21.6-253 VAC \/ 19.2-300 VDC), the rugged 5104B, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers reliable loop power as well as galvanic isolation for two-wire transmitters and analog current\/voltage signals in automation systems. Furthermore, its compact DIN-rail mountable form factor makes it ideal for dense installations and efficient control panels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5104B provides 1:1 or signal conversion of analog current \/ voltage signals.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupply voltage and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eIntrinsically Safe\u003c\/a\u003e (I.S.) safety barrier for 2-wire transmitters for mounting in a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous area\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eSafety barrier for analog current \/ voltage signals from a hazardous area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5104B Ex Repeater and Power Supply from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing 3.75 kVAC galvanic isolation between inputs, outputs, and power, the PR 5104B Ex Repeater and Power Supply ensures signal integrity and protects equipment from electrical noise and ground loops. This makes it perfect for industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eprocess control\u003c\/a\u003e, \u003ca href=\"https:\/\/www.psctexas.shop\/products\" title=\"Industrial Instrumentation\"\u003einstrumentation\u003c\/a\u003e, and factory automation environments where accurate signal transmission is essential. Furthermore, the PR 5104B features 20 factory-calibrated measurement ranges selectable via DIP switches without the need for recalibration, thus offering flexibility for various analog signal types.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 20 factory-calibrated measurement ranges in the 5104B can be selected by the internal DIP-switches without the need for recalibration.\u003c\/li\u003e\n\u003cli\u003eSpecial measurement ranges are available. \u003c\/li\u003e\n\u003cli\u003ePR 5104B relies on microprocessor technology for gain and offset. \u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating as well as galvanically separated.\u003c\/li\u003e\n\u003cli\u003eThe output can connect either as an active current \/ voltage transmitter or as a 2-wire transmitter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eWith a fast response time of \u0026lt; 25 ms and excellent EMC performance in accordance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21, the PR 5104B enhances system responsiveness and reduces susceptibility to electrical interference. The output of the PR 5104B Ex Repeater and Power Supply can configure as either an active current\/voltage transmitter or a two-wire loop transmitter, thus supporting wide application versatility. Built for durability and precision, the 5104B is an essential component for industrial signal isolation and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003epower solutions\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eBy way of the 2-channel version, users can mount up to 84 channels per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5104-repeater-and-power-supply-pr-electronics-5104B-signal-repeater-instrumentation-power-supply-process-solutions-corp-psc-texas.jpg?v=1769200405\" alt=\"PR-5104-repeater-and-power-supply-pr-electronics-5104B-signal-repeater-instrumentation-power-supply-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369091715,"sku":"5104B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5104B-Repeater-and-Power-Supply-PR-electronics-signal-repeater-din-rail-power-supply-process-solutions-psc-texas.jpg?v=1769443754"},{"product_id":"pr-5105b-ex-isolated-driver","title":"PR 5105B Ex Isolated Driver","description":"\u003cp\u003eThe PR 5105B Ex Isolated Driver is a highly reliable, isolated \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e interface with \u003ca rel=\"noopener\" title=\"UL Standards\" href=\"https:\/\/www.ul.com\/resources\/apps\/standards-catalog\" target=\"_blank\"\u003eUL 913\u003c\/a\u003e approval that's ideal for \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and industrial environments. With excellent precision and safety, this Ex Isolated Driver, from \u003ca rel=\"noopener\" title=\"PR electronics 5104B Ex Isolated Driver\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/ex-isolated-driver-5105b-u9\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, provides galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e up to 3.75 kVAC across 1- or 2-channel configurations. Thus, the 5105B ensures secure transmission of analog current and voltage signals into intrinsically safe areas without compromising signal integrity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety barrier for current signals transmitted to I\/P converters and displays in hazardous areas. \u003c\/li\u003e\n\u003cli\u003eSafety barrier for analog current \/ voltage signals transmitted to hazardous area.\u003c\/li\u003e\n\u003cli\u003e1:1 or signal conversion of analog current \/ voltage signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5105B Ex Isolated Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing 20 factory-calibrated measurement ranges selectable via internal DIP switches, the PR 5105B Ex Isolated Driver eliminates the need for recalibration. Furthermore, it supports flexible, rapid deployment in diverse industrial applications. The 5105B features universal AC\/DC \u003ca title=\"Power and Supply Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e compatibility and a fast response time of less than 25 ms. In addition, the PR 5105B delivers dependable performance for I\/P converters, displays, and other critical \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eprocess control\u003c\/a\u003e equipment in Ex and I.S. zones.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 20 factory-calibrated measurement ranges in the 5105B-U9 can be selected by the internal DIP-switches without the need for a recalibration.\u003c\/li\u003e\n\u003cli\u003eSpecial measurement ranges are available.\u003c\/li\u003e\n\u003cli\u003eThe PR 5105 is based on microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eRobustly built for demanding conditions, the 5105B Ex Isolated Driver includes floating, galvanically separated inputs, outputs, and power, thus maximizing safety and protection in complex installations. Simple DIN rail mounting and compact construction allow efficient use of space and high-density channel installations. Whether upgrading existing instrumentation or integrating new process control systems, the PR 5105 delivers precision, certification-grade reliability, and ease of installation. As a result, this Ex Isolated Drive is an ideal choice for process automation and hazardous area signal isolation needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eBy way of the 2-channel version up to 84 channels per meter can mount.\u003c\/li\u003e\n\u003cli\u003eThe PR 5105B features approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5105B-Ex-Isolated-Driver-PR-electronics-signal-isolation-galvanic-isolator-intrinsic-safety-barrier-process-solutions-corp-psc-texas.jpg?v=1769452264\" alt=\"PR-5105B-Ex-Isolated-Driver-PR-electronics-signal-isolation-galvanic-isolator-intrinsic-safety-barrier-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5105BA: 1-Channel","offer_id":46398801051779,"sku":"5105BA","price":395.0,"currency_code":"USD","in_stock":true},{"title":"5105BB: 2-Channel","offer_id":46398801084547,"sku":"5105BB","price":564.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5105B-Ex-Isolated-Driver-PR-electronics-Galvanic-Isolation-Signal-Transmitter-Process-Solutions-Corp-PSC-Texas.jpg?v=1769452806"},{"product_id":"pr-5106b-hart-ex-transparent-repeater","title":"PR 5106B HART Ex Transparent Repeater","description":"\u003cp\u003eThe PR 5106B Ex HART Transparent Repeater is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e and \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e device for industrial process automation systems. The 5106B, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports robust \u003ca title=\"HART Protocol Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication and accurate analog signal transmission. This DIN-rail mountable HART transparent repeater provides reliable galvanic isolation up to 3.75 kVAC across its multiple ports. Thus, the PR 5106B ensures safe separation of input, output, as well as supply circuits in demanding environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003ePower supply\u003c\/a\u003e and \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eIntrinsically Safe\u003c\/a\u003e (I.S.) safety barrier with 2-way HART communication for 2-wire transmitters in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eI.S. safety barrier with 2-way HART communication for supplied current transmitters in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eSignal isolator with fast response time on analog current signals from hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5106B Ex HART Transparent Repeater from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing microprocessor-based technology for gain and offset, the PR 5106B Ex HART Transparent Repeater efficiently processes 4-20 mA current loops with exceptional accuracy and a fast response time of less than 25 ms. Thus, the 5106B is ideal for real-time monitoring and \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eautomation control\u003c\/a\u003e applications. Its floating, galvanically isolated inputs and outputs help protect sensitive field transmitters and control systems from electrical noise and interference in addition to enhancing system stability and uptime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106B primarily processes current signals of 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eThis HART Transparent Repeater relies upon microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003cli\u003eThe output can connect either as an active current transmitter or as a 2-wire transmitter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for flexible installation, the PR 5106B Ex HART Transparent Repeater supports both active current transmitter connections and 2-wire transmitter modes with universal AC\/DC power compatibility. Its compact form factor allows up to 84 channels per meter of DIN rail space, thus minimizing cabinet footprint in high-density applications. Whether extending HART signal range, isolating system loops, or improving communication reliability in distributed control systems (DCS) and SCADA networks, the 5106B delivers precision, safety, and durability for industrial signal management needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5106B can mount vertically or horizontally on a DIN rail. \u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without distance between neighboring units, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5106-HART-Transparent-Repeater-PR-electronics-5106A-5106B-Signal-Isolation-Signal-Repeater-Process-Solutions-Corp-PSC-Texas.jpg?v=1769527116\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369157251,"sku":"5106B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/5106b.png?v=1769539175"},{"product_id":"pr-5107b-hart-ex-transparent-driver","title":"PR 5107B HART Ex Transparent Driver","description":"\u003cp\u003eThe 5107B, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, has been discontinued and is no longer in production. We recommend considering the \u003ca href=\"https:\/\/www.psctexas.shop\/products\/pr-9107-hart-transparent-driver\" title=\"PR electronics 9107B HART Transparent Driver\"\u003ePR 9107B\u003c\/a\u003e HART Transparent Driver.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5107B HART Ex Transparent Driver from PR electronics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSafety barrier for current signals and 2-way \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Devices\"\u003eHART communication\u003c\/a\u003e transmitting to I\/P converters in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eSafety barrier for 2-way HART communication and analog current signals transmitting to hazardous area.\u003c\/li\u003e\n\u003cli\u003eSignal \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolator\u003c\/a\u003e with low response time on analog current signals transmitting to hazardous area.\u003c\/li\u003e\n\u003cli\u003ePR's HART transparent driver primarily processes current signals of 4-20 mA.\u003c\/li\u003e\n\u003cli\u003ePR 5107B relies upon microprocessor technology for gain and offset.\u003c\/li\u003e\n\u003cli\u003eThe analog signal transmits at a response time of less than 25 ms.\u003c\/li\u003e\n\u003cli\u003eInputs, outputs, and supply are floating and galvanically separated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe 5107B mounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without distance between neighboring units, up to 84 channels can mount per meter.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369190019,"sku":"5107B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/5107b.png?v=1769528601"},{"product_id":"pr-5116b-ex-programmable-transmitter","title":"PR 5116B Ex Programmable Transmitter","description":"\u003cp\u003eThe PR 5116B Ex Programmable Transmitter is an \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, high-performance, multifunctional \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for industrial process automation, monitoring, and control applications. Featuring universal input compatibility for RTD, thermocouple (TC), mV, ohm, potentiometer, mA, and voltage signals, the 5116B, from \u003ca href=\"https:\/\/www.prelectronics.com\/\" title=\"PR electronics 5116 Programmable Transmitter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, consolidates multiple sensor types into one versatile device, thus reducing inventory and installation complexity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly valves or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003ePower supply\u003c\/a\u003e and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control with 2 potential-free relay contacts which can configure for advanced functions.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation of analog signals and measurement of floating signals.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/programmable-transmitter-5116b\/\" title=\"PR electronics 5116B Ex Programmable Transmitter\" target=\"_blank\"\u003ePR 5116B\u003c\/a\u003e Ex Programmable Transmitter is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX and FM approval.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5116B Ex Programmable Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith both current (0-20 mA) and voltage (0-10 VDC) outputs, plus two configurable relay outputs, the PR 5116B Ex Programmable Transmitter gives process engineers extensive control options. The transmitter’s 3-port galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e (3.75 kVAC) enhances electrical safety, minimizes noise interference, and also protects downstream control systems against signal distortion. Universal AC\/DC power compatibility provides installation flexibility across global facilities, while DIN-rail mounting maximizes cabinet space efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds users can program the PR 5116B to suit any specific application.\u003c\/li\u003e\n\u003cli\u003eBy way of the front push-button, the input can calibrate to the exact span of the process.\u003c\/li\u003e\n\u003cli\u003eZero drift on the process signal can adjust by a single press of the front button.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eA yellow LED is ON for each active output relay.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e3-port 3.75 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eProgramming the PR 5116B is fast and intuitive. Users can configure input spans and output behavior via the front push-button interface, including zero-drift adjustment, or use Loop Link communications interface for advanced setup. A front LED panel clearly indicates operating status as well as relay activity for easy diagnostics. Applications include linearized temperature measurement, resistance signal conversion from \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e and position sensors, two-wire transmitter power and signal isolation, and process control with configurable relay functions. The PR 5116B Ex Programmable Transmitter delivers dependable accuracy (± 0.05%) in addition to rugged reliability for the most demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5116B can mount vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eAs the 5116B can mount without any distance between neighboring units, up to 42 devices can mount per meter.\u003c\/li\u003e\n\u003cli\u003eThe PR 5116B Ex Programmable Transmitter \u003cmeta charset=\"utf-8\"\u003efeatures approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-5116-Programmable-Transmitter-PR-electronics-wiring-diagram-multifunctional-automation-signal-transmitter-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5116-Programmable-Transmitter-PR-electronics-wiring-diagram-multifunctional-automation-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769547399\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369353859,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5116-B-Programmable-Transmitter-PR-electronics-universal-signal-transmitter-automation-control-process-solutions-psc-texas.jpg?v=1769549886"},{"product_id":"pr-5131b-2-wire-ex-programmable-transmitter","title":"PR 5131B 2-wire Ex Programmable Transmitter","description":"\u003cp\u003eThe PR 5131B 2‑wire Ex Programmable Transmitter is a versatile industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for accurate \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e and reliable process control. Featuring universal inputs for RTD, thermocouple (TC), mV, linear resistance, current (mA), and voltage (V), the 5131B, from \u003ca rel=\"noopener\" title=\"PR electronics 5131B 2-wire Ex Programmable Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/2-wire-programmable-transmitter-5131b\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers flexible integration across a wide range of sensing applications. This 2-wire temperature transmitter converts sensor inputs into a standardized 4-20 mA loop output, thus simplifying connection to \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS systems, and analog input modules for streamlined industrial automation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis transmitter can configure with \u003ca title=\"PR electronics PReset Programming Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset\u003c\/a\u003e programming software using a standard PC and the PR 5909 Loop Link communications unit.\u003c\/li\u003e\n\u003cli\u003eThe PR 5131B 2-wire Ex Temperature Transmitter is \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5131B 2-wire Ex Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for performance and safety, the PR 5131B 2-wire Ex Temperature Transmitter features 3.75 kVAC galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e, protecting sensitive control equipment from electrical noise and interference. As a result, the 5131B also enhances system reliability. Its jumper-selectable inputs allow independent channel configuration for temperature or current \/ voltage measurement, thus providing customization for specific process requirements. The transmitter supports automatic cable compensation (3- or 4-wire) and programmable cable resistance for 2-wire setups.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent channel jumper selectable inputs for current \/ voltage or temperature. \u003c\/li\u003e\n\u003cli\u003eCurrent input programmable in range 0-100 mA and voltage inputs in range 0-250 VDC.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly \u003ca title=\"Valve Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/valves\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation.\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor error detection including \u003ca rel=\"noopener\" title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration is easy using PReset software and the Loop Link communications interface, thus enabling precision tuning and rapid deployment across facilities. DIN-rail mounting ensures compact installation and efficient use of cabinet space. In addition, programmable sensor error detection, including NAMUR NE43 compliance, delivers improvements in safety and diagnostic feedback. Ideal for temperature monitoring, resistance signal conversion, and process measurement tasks, the PR 5131B 2-wire Ex Temperature Transmitter offers dependable performance for demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 2-channel version has full galvanic isolation between the channels.\u003c\/li\u003e\n\u003cli\u003eSeparation of circuits in PELV\/SELV installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas.jpg?v=1769552245\" alt=\"PR-5131-2-wire-temperature-transmitter-pr-electronics-5131a-5131b-pr5131-universal-temperature-converter-signal-transmitters-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369386627,"sku":"5131B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5131-B-2-wire-ex-temperature-transmitter-pr-electronics-intrinsically-safe-temperature-converter-process-solutions-psc-texas.jpg?v=1769552538"},{"product_id":"pr-5203b-ex-solenoid-and-alarm-driver","title":"PR 5203B Ex Solenoid and Alarm Driver","description":"\u003cp\u003eThe PR 5203B Ex Solenoid and Alarm Driver is an \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e driver that's ideal for controlling solenoids, LEDs, and acoustic alarms in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous area\u003c\/a\u003e industrial environments. With UL 913 certification for the U.S. market, the 5203B, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5200\/ex-solenoid-alarm-driver-5203b-u9\/\" target=\"_blank\" title=\"PR electronics 5203B Ex Solenoid and Alarm Driver\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, supports 1- or 2-channel configurations. Furthermore, this driver provides reliable ON\/OFF voltage control with digitally regulated output, making it perfect for safety-critical applications in oil and gas, chemical processing, and industrial automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDriver with safety barrier for the control of ON\/OFF solenoids in hazardous areas. \u003c\/li\u003e\n\u003cli\u003eDriver with safety barrier for the supply of LEDs and acoustic alarms in hazardous areas. \u003c\/li\u003e\n\u003cli\u003eVoltage supply with ON\/OFF control of other equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5203B Ex Solenoid and Alarm Driver from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing 3- and 5-port galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e at 3.75 kVAC, the PR 5203B Ex Solenoid and Alarm Driver delivers robust electrical separation between its supply, inputs, and outputs. Thus, the 5203B minimizes interference and protects sensitive equipment. Its universal AC\/DC power supply (21.6-253 VAC or 19.2-300 VDC) enables flexible installation across global installations. Furthermore, its compact DIN-rail mounting supports up to 84 channels per meter in high-density control panels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5203B has a digital input per channel for the control of the I.S. output voltage. \u003c\/li\u003e\n\u003cli\u003eSupply, inputs, and outputs are floating and galvanically separate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing floating, galvanically separate I.S. outputs and digital control inputs, the PR 5203B ensures dependable operation in intrinsically safe (I.S.) zones and simplifies integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e and control systems. With robust EMC performance and industry certifications, this Ex Solenoid and Alarm Driver stands out as a durable, efficient solution for managing solenoids and alarm circuits under demanding conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eBy way of the 2-channel version up to 84 channels per meter can mount.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5203-Ex-Solenoid-and-Alarm-Driver-PR-electronics-galvanic-isolator-intrinsically-safe-safety-barrier-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769698476\" alt=\"PR-5203-Ex-Solenoid-and-Alarm-Driver-PR-electronics-galvanic-isolator-intrinsically-safe-safety-barrier-signal-transmitter-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5203BF1: I.S. Type F; 1-Channel","offer_id":46445636812931,"sku":"5203BF1","price":348.0,"currency_code":"USD","in_stock":true},{"title":"5203BH1: I.S. Type H; 1-Channel","offer_id":46445636845699,"sku":"5203BH1","price":348.0,"currency_code":"USD","in_stock":true},{"title":"5203BH2: I.S. Type H; 2-Channel","offer_id":46445636878467,"sku":"5203BH2","price":430.0,"currency_code":"USD","in_stock":true},{"title":"5203BI1: I.S. Type I; 1-Channel","offer_id":46445636911235,"sku":"5203BI1","price":348.0,"currency_code":"USD","in_stock":true},{"title":"5203BI2: I.S. Type I; 2-Channel","offer_id":46445636944003,"sku":"5203BI2","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5203B-Ex-Solenoid-and-Alarm-Driver-PR-electronics-galvanic-isolation-safety-barrier-signal-driver-process-solutions-corp-psc-texas.jpg?v=1769699582"},{"product_id":"pr-5223a-programmable-fi-ff-converter","title":"PR 5223A Programmable f\/I-f\/f Converter","description":"\u003cp\u003eThe PR 5223A Programmable f\/I‑f\/f Converter is a high-performance, programmable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e for industrial automation and process control applications. Ideal for converting \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/frequency-and-pulse\" title=\"Frequency and Pulse Devices\"\u003efrequency\u003c\/a\u003e signals into precise analog current or voltage outputs, this versatile device supports both frequency-to-current (f\/I) and frequency-to-frequency (f\/f) functions. Thus, the 5223A, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/special-devices\/5200\/programmable-f-i-f-f-converter-5223a\/\" title=\"PR electronics 5223A Programmable f\/I-f\/f Converter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for pulse calculation, frequency scaling, division, multiplication, as well as buffering of fast pulse trains. Featuring universal power supply compatibility with 21.6-253 VAC or 19.2-300 VDC, the PR 5223A ensures flexible installation across a broad range of system configurations. Furthermore, its galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e (3.75 kVAC) protects sensitive inputs and outputs from electrical noise and interference, enhancing reliability in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5223A Programmable f\/I-f\/f Converter can configure with a standard PC and the Loop Link communications unit, or deliver with fully configuration.\u003c\/li\u003e\n\u003cli\u003eThe f\/I function performs frequency to current and voltage conversion.\u003c\/li\u003e\n\u003cli\u003eThe f\/f function, for pulse division or multiplication, can also act as a buffer for collecting fast pulse trains.\u003c\/li\u003e\n\u003cli\u003eUsers can enter a scale factor in all functions.\u003c\/li\u003e\n\u003cli\u003eUsing both digital inputs, pulse addition or subtraction are possible.\u003c\/li\u003e\n\u003cli\u003eThe frequency generator function is used as, for example, a time base or clock generator.\u003c\/li\u003e\n\u003cli\u003eInput and supply polarity reversal protection.\u003c\/li\u003e\n\u003cli\u003eCurrent and voltage output signals galvanically separate from the supply and the inputs.\u003c\/li\u003e\n\u003cli\u003eProgrammable digital outputs including NPN, PNP, or relay options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5223A Programmable f\/I-f\/f Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 5223A Programmable f\/I-f\/f Converter accommodates a wide variety of input sensors including \u003ca href=\"https:\/\/www.namur.net\/en\" target=\"_blank\" title=\"NAMUR Association\" rel=\"noopener\"\u003eNAMUR\u003c\/a\u003e, tacho, NPN, PNP, TTL, S0, and contact signals over a 0-20,000 Hz range, with programmable analog outputs (0-20 mA or 0-10 V) for seamless integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003econtrol systems\u003c\/a\u003e. With programmable digital outputs (PNP, NPN, or optional relays) and built-in LED indicators for input\/output status and error detection, the 5223A enhances diagnostics and operational visibility. Configuration is easy via a standard PC and the PR Loop Link communications interface, or it can ship with preconfiguration for specific applications. This programmable f\/I-f\/f converter delivers dependable performance, flexibility, and precision, thus it's perfect for frequency conditioning in industrial automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.\u003c\/li\u003e\n\u003cli\u003eAnalog current output can be configured to any current within 0...20 mA range.\u003c\/li\u003e\n\u003cli\u003eVoltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.\u003c\/li\u003e\n\u003cli\u003eInput range:\n\u003cul\u003e\n\u003cli\u003eFrequency: 0...20,000 Hz\u003c\/li\u003e\n\u003cli\u003eSensor types: NAMUR, tacho, NPN, PNP, TTL, S0, contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput range:\n\u003cul\u003e\n\u003cli\u003eCurrent and voltage output: 0-20 mA \/ 0-10 V\u003c\/li\u003e\n\u003cli\u003eRelay outputs: 0-20 Hz\u003c\/li\u003e\n\u003cli\u003eNPN and PNP output as f\/f: 0-1000 Hz\u003c\/li\u003e\n\u003cli\u003eNPN and PNP output as generator: 0-20,000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5223A-Programmable-f-i-f-f-Converter-PR-electronics-programmable-frequency-converter-calculator-signal-pulse-conversion-process-solutions-psc-texas.jpg?v=1769701585\" alt=\"PR-5223A-Programmable-f-i-f-f-Converter-PR-electronics-programmable-frequency-converter-calculator-signal-pulse-conversion-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5223A1: 2 NPN\/PNP Outputs","offer_id":46445818871939,"sku":"5223A1","price":704.0,"currency_code":"USD","in_stock":true},{"title":"5223A2: 2 SPST Relay Outputs","offer_id":46445818904707,"sku":"5223A2","price":751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5223A-Programmable-f-i-f-f-Converter-PR-electroincs-frequency-converter-signal-pulse-conversion-current-voltage-converter-process-solutions-corp-psc-texas.jpg?v=1769702073"},{"product_id":"pr-4511-modbus-communication-enabler","title":"PR 4511 Modbus Communication Enabler","description":"\u003cp\u003eThe PR 4511 Modbus Communication Enabler is a powerful industrial interface accessory that transforms \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e devices into fully network-capable instruments. The 4511, from \u003ca title=\"PR electronics 4511 Modbus Communication Enabler\" href=\"https:\/\/www.prelectronics.com\/products\/communication-interfaces\/4500\/communication-enabler-4511\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for attaching easily to PR 4000 and PR 9000 series transmitters and converters. Furthermore, the PR 4511 adds \u003ca title=\"Modbus Protocol\" href=\"https:\/\/www.modbus.org\/\" target=\"_blank\"\u003eModbus\u003c\/a\u003e RTU communication over RS-485, thus enabling \u003ca title=\"Industrial Wireless Monitoring Systems\" href=\"https:\/\/www.psctexas.shop\/products\/industrial-wireless-monitoring-systems\"\u003eremote monitoring\u003c\/a\u003e, \u003ca title=\"Data Logging and Acquisition\" href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\"\u003edata logging\u003c\/a\u003e, and digital integration across automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 4511 detachable display adds Modbus RTU RS-485 serial communications to all current and future PR 4000 and PR 9000 units. \u003c\/li\u003e\n\u003cli\u003eThe 4511 Modbus Communication Enabler converts a wide array of sensors and analog device signals from the PR 4000 series, like unipolar and bipolar mA and voltage signals, potentiometer, Lin. R, RTD, and TC, to a Modbus communication line signal.\u003c\/li\u003e\n\u003cli\u003eWhen mounting on a PR 9000 device, any signal coming from or going to I.S. \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e, like AI, AO, DI, and DO signals, can convert to a Modbus network. \u003c\/li\u003e\n\u003cli\u003eAll individual unit operating parameters can easily and quickly configure by using Modbus communication or by using the front display menu.\u003c\/li\u003e\n\u003cli\u003eThe easily readable PR 4511 programming interface can allow users to read the process signal, simulate the output signal, and indicate sensor and internal device errors. \u003c\/li\u003e\n\u003cli\u003eThe 4511 display can easily move from one device to another. \u003c\/li\u003e\n\u003cli\u003eThe individual system PR 4000, PR 9000, and select PR 3000 device configuration of a transmitter can save and download to subsequent transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4511 Modbus Communication Enabler from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith robust 2.5 kVAC galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between the communication interface and host unit, the PR 4511 Modbus Communication Enabler provides safe, reliable digital connectivity while retaining original analog process signals. This detachable programming module includes a built-in high-visibility display for local monitoring of process values, simulation of output signals, sensor error indications, and internal diagnostics. Thus the 4511 helps users troubleshoot and configure systems quickly. Ideal for process control, remote assets, and industrial automation networks, the PR 4511 Modbus Communication Enabler supports multidrop Modbus configurations, thus allowing up to 32 units on a single RS-485 line.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 4511 has full functionality for unit programming, process signal monitoring, and diagnostics handling. \u003c\/li\u003e\n\u003cli\u003eMultidrop half-duplex connection via shielded RJ45 connector.\u003c\/li\u003e\n\u003cli\u003eHigh safe galvanic isolation of 2.5 kVAC between the serial wiring and the connected system PR 4000 and PR 9000 units. \u003c\/li\u003e\n\u003cli\u003eModbus parameters such as address, baud rate, stop bit(s), and parity bit configure from the 4511 display, which also stores parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting and Programming\u003c\/h2\u003e\n\u003cp\u003eParameters such as address, baud rate, and parity are user-configurable via the PR 4511 display and store locally for consistent operation. With certification for Zone 2 \/ Division 2 hazardous areas, the PR 4511 Modbus Communication Enabler enhances connectivity in demanding environments while preserving system integrity. Furthermore, the 4511 boosts automation capabilities, simplifies diagnostics, and bridges analog measurement hardware with modern control networks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting in Zone 2 \/ Div 2.\u003c\/li\u003e\n\u003cli\u003eAll configuration data from PR 4000, PR 9000, and select PR 3000 series devices can transfer to a PC using the PR 4590. \u003c\/li\u003e\n\u003cli\u003eProgrammed parameters can be protected by a user-defined password.\u003c\/li\u003e\n\u003cli\u003eWhen mounting on devices that install upside down, a menu item allows the display on the PR 4511 to rotate 180˚ and also allows the up\/down buttons to switch function.\u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 4510 features approval for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 25px; float: none;\" alt=\"PR-4511-modbus-communication-enabler-pr-electronics-signal-conditioner-programming-interface-display-front-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4511-modbus-communication-enabler-pr-electronics-signal-conditioner-programming-interface-display-front-process-solutions-corp-psc-texas.jpg?v=1769184716\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369583235,"sku":"4511","price":139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4511-Modbus-Communication-Enabler-PR-electronics-signal-conditioning-programming-interface-display-process-solutions-corp-psc-texas.jpg?v=1769184739"},{"product_id":"pr-4104-universal-unipolar-bipolar-signal-transmitter","title":"PR 4104 Universal Unipolar \/ Bipolar Signal Transmitter","description":"\u003cp\u003eThe PR 4104 Universal Unipolar \/ Bipolar Signal Transmitter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e and conversion device for industrial automation, control systems, and process measurement applications. This versatile \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/universal-transmitters\" title=\"Universal Transmitters\"\u003euniversal transmitter\u003c\/a\u003e accepts both unipolar and bipolar voltage (±12 V) and current (±23 mA) signals, active or passive, as well as converts them into configurable outputs. Thus, the 4104, from \u003ca title=\"PR electronics 4104 Universal Unipolar \/ Bipolar Signal Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4100\/universal-uni-bipolar-signal-transmitter-4104\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, makes for easy integration with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e, DCS, and SCADA systems. Its universal power supply ranges from 21.6-253 VAC or 19.2-300 VDC, thus making it suitable for a wide variety of global installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast \u0026lt; 20 ms response time for measuring signals from torque, position, current, as well as acceleration sensors.\u003c\/li\u003e\n\u003cli\u003eUser configurable bipolar or unipolar I\/O means the PR 4104 is suitable for nearly any voltage or current conversion. \u003c\/li\u003e\n\u003cli\u003eThe excitation source enables measurement of two or three wire transmitters.\u003c\/li\u003e\n\u003cli\u003eThe active or passive I\/O makes the 4104 perfect for power matching current loops.\u003c\/li\u003e\n\u003cli\u003eConverts narrow bipolar inputs to wide bipolar or unipolar outputs, for example, ±1 volt input = ±10 volt or 4-20 mA output.\u003c\/li\u003e\n\u003cli\u003eSelectable direct or inverse I\/O makes the PR 4104 suitable for proportional control applications. \u003c\/li\u003e\n\u003cli\u003eThe \"V-curve\" function outputs 100% – 0 – 100% when a 0 – 100% input signal is present.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4104 Universal Unipolar \/ Bipolar Signal Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe \u003cmeta charset=\"utf-8\"\u003ePR 4104 Universal Unipolar \/ Bipolar Signal Transmitter features a fast response time of \u0026lt;20 ms, excellent accuracy better than 0.05 % of span, and a high signal-to-noise ratio of \u0026gt;60 dB. Furthermore, the 4104 delivers precise signal conversion in demanding industrial environments. It supports programmable unipolar and bipolar outputs (including 0–20 mA, 4–20 mA, ±10 mA and ±20 mA), selectable direct or inverted action, in addition to unique \"V-curve\" scaling for advanced process control applications. Built with robust 2.3 kVAC galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e and compliance with \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21\/NE43 EMC standards, this universal unipolar \/ bipolar signal transmitter excels in electrically noisy settings while providing reliable sensor error detection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.\u003c\/li\u003e\n\u003cli\u003eThe current output can drive up to 800 Ohms, with an adjustable response time of 0.0-60.0 seconds.\u003c\/li\u003e\n\u003cli\u003eExceptional mA output load stability of \u0026lt; 0.001% of span\/100 Ohm.\u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE21 recommendations, thus ensuring high accuracy in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE43 recommendations, thus allowing the control system to easily detect a sensor error. \u003c\/li\u003e\n\u003cli\u003eEach unit is tested to a high 2.3 kVAC, 3-port galvanic isolation level.\u003c\/li\u003e\n\u003cli\u003eExcellent signal to noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eInstallation is streamlined via DIN-rail mounting and programming can be accomplished using \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR electronics 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e detachable display interfaces. The PR 4104 Universal Unipolar \/ Bipolar Signal Transmitter is ideal for industrial signal conversion in motion control, torque measurement, position feedback, and current\/voltage transducer systems, delivering versatile performance as well as long-term reliability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVery low power consumption means units can mount side by side without an air gap – even at 140˚F (60˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e. \u003c\/li\u003e\n\u003cli\u003eConfiguration, monitoring, 2-point process calibration and more are accomplished using PR's 4500 series of detachable displays.\u003c\/li\u003e\n\u003cli\u003eAll programming can be password protected.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4104-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-universal-signal-transmitter-industrial-automation-signal-converter-process-solutions-psc-texas.jpg?v=1769031180\" alt=\"PR-4104-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-universal-signal-transmitter-industrial-automation-signal-converter-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369616003,"sku":"4104","price":232.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4104-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-universal-signal-transmitter-industrial-automation-process-solutions-corp-psc-texas.jpg?v=1769031534"},{"product_id":"pr-4116-universal-transmitter","title":"PR 4116 Universal Transmitter","description":"\u003cp\u003eThe PR 4116 Universal Transmitter is a flexible, industrial-grade \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e solution for simplifying process measurement and \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eautomation control\u003c\/a\u003e. This multifunctional transmitter, the 4116 from \u003ca title=\"PR electronics 4116 Universal Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4100\/universal-transmitter-4116\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, accepts virtually any sensor input, including RTDs (resistance temperature detectors), thermocouples (TC), resistance (Ohm), potentiometers, mA and voltage (V) signals. Thus, users can standardize diverse field signals into reliable analog outputs for controllers, PLCs, and \u003ca title=\"Data Logging and Acquisition\" href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\"\u003edata acquisition\u003c\/a\u003e systems.\u003c\/p\u003e\n\u003cp\u003eWhether you’re converting \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, resistance, or process signals, the PR 4116 Universal Transmitter delivers precision, safety, and adaptability. As a result, the 4116 reduces inventory complexity and improves system uptime across industrial automation applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/position-sensors\" title=\"LVDT Position Sensors\"\u003elinear movements\u003c\/a\u003e with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolator\u003c\/a\u003e for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control with 2 pairs of potential-free relay contacts and analog output.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation of analog signals and measurement of floating signals.\u003c\/li\u003e\n\u003cli\u003eThe PR 4116 provides the required failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 4116 correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4116 Universal Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding industrial environments, the PR 4116 Universal Transmitter features a universal AC\/DC supply, current and voltage outputs, and two potential-free relay contacts for versatile control and alarm functions. FM approval for Division 2 \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous area\u003c\/a\u003e installations and advanced safety design make it suitable for mission-critical applications, including those requiring SIL 2 and PL \"d\" performance levels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the PR 4116 is used in combination with the \u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e display series, all operational parameters can be modified to suit any application.\u003c\/li\u003e\n\u003cli\u003eAs the 4116 features electronic hardware switches, it isn't necessary to open the device for setting of DIP-switches.\u003c\/li\u003e\n\u003cli\u003eA green \/ red front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eA yellow LED is ON for each active output relay.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e4-port 2.3 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eInstallation and configuration are straightforward with the detachable PR 4500 series programming interface, thus enabling easy setup, two-point calibration, and password-protected parameter control without internal access. Low power consumption supports dense DIN-rail mounting even at high ambient temperatures, while robust galvanic isolation minimizes electrical noise and also enhances signal integrity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVery low power consumption means units can mount side by side without an air gap – even at 140˚F (60˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eConfiguration, monitoring, 2-point process calibration and more are accomplished using PR's 4500 series of detachable displays.\u003c\/li\u003e\n\u003cli\u003eAll programming can be password-protected.\u003c\/li\u003e\n\u003cli\u003eFeatures approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-top: 025px; float: none;\" alt=\"PR-4116-Universal-Transmitter-PR-electronics-multifunctional-signal-transmitter-universal-signal-converter-industrial-automation-control-process-solutions-corp-psc-texas\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4116-Universal-Transmitter-PR-electronics-multifunctional-signal-transmitter-universal-signal-converter-industrial-automation-control-process-solutions-corp-psc-texas.jpg?v=1769093236\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369681539,"sku":"4116","price":294.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4116-Universal-Transmitter-PR-electronics-multifunctional-signal-transmitters-process-solutions-corp-psc-texas.jpg?v=1769093256"},{"product_id":"pr-4131-universal-trip-amplifier","title":"PR 4131 Universal Trip Amplifier","description":"\u003cp\u003eThe PR 4131 Universal Trip Amplifier is a high-performance industrial \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device that enhances safety and control in process automation systems. This versatile universal trip amplifier accepts a wide range of inputs, including RTDs, thermocouples (TC), resistance (Ohm), potentiometers, mA and voltage signals. Thus, the 4131, from \u003ca title=\"PR electronics 4131 Universal Trip Amplifier\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4100\/universal-trip-amplifier-4131\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is perfect for applications requiring precision monitoring, alarm triggering, and process protection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable via detachable display front (\u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e series).\u003c\/li\u003e\n\u003cli\u003eFeatures process calibration, relay simulation, password protection, error diagnostics, as well as selection of help text in several languages. \u003c\/li\u003e\n\u003cli\u003eProcess control with 2 pairs of potential-free relay contacts which can configure to suit any application. \u003c\/li\u003e\n\u003cli\u003eTrip amplifier with window function defined by a high and a low setpoint.\u003c\/li\u003e\n\u003cli\u003eThe relay changes state outside the window.\u003c\/li\u003e\n\u003cli\u003eRelay latch function, where the relay is active and can only be reset manually.\u003c\/li\u003e\n\u003cli\u003eSophisticated sensor error surveillance, where one relay holds the state immediately prior to the sensor error, thus allowing the process to continue.\u003c\/li\u003e\n\u003cli\u003eThe other relay can be set for sensor error alarm so that the defective sensor can be replaced immediately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4131 Universal Trip Amplifier from PR electronics\u003c\/h2\u003e\n\u003cp\u003eBuilt for reliability, the PR 4131 Universal Trip Amplifier features two adjustable alarm limits and dual relay outputs. The alarms and outputs can configure for window, latch or sensor-error functions, thus providing flexible control in complex systems. Its universal AC\/DC power supply supports deployment in diverse industrial environments, while FM approval for Division 2 installations ensures safety compliance in \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous locations\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the PR 4131 is used with the PR 4500 display series, all operational parameters can be modified to suit any application.\u003c\/li\u003e\n\u003cli\u003eAs the 4131 features electronic hardware switches, it isn't necessary to open the device for setting of DIP-switches.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eA yellow LED is ON for each active output relay.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e3-port 2.3 kVAC galvanic \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eUsers will appreciate the detachable PR 4500 series programming display, which simplifies configuration, process calibration, and relay simulation without opening the unit. Advanced monitoring functions include sensor error supervision and continuous safety checks of critical stored data, enhancing operational uptime and reducing maintenance.\u003c\/p\u003e\n\u003cp\u003eWith robust 3-port galvanic isolation and clear LED status indicators, the PR 4131 Universal Trip Amplifier delivers dependable alarm signaling, precise sensor monitoring, and seamless integration with \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003ePLCs\u003c\/a\u003e and control systems. Thus, the 4131 is an essential component in modern industrial automation, safety, and process control solutions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures approval for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4131-Universal-Trip-Amplifier-PR-electronics-Universal-Signal-Amplifier-Process-Automation-Control-Process-solutions-psc-texas.jpg?v=1769094631\" alt=\"PR-4131-Universal-Trip-Amplifier-PR-electronics-Universal-Signal-Amplifier-Process-Automation-Control-Process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369714307,"sku":"4131","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4131-Universal-Trip-Amplifier-PR-electronics-signal-amplifier-process-solutions-corp-psc-texas.jpg?v=1769094930"},{"product_id":"pr-4179-universal-ac-dc-transmitter","title":"PR 4179 Universal AC \/ DC Transmitter","description":"\u003cp\u003eThe PR 4179 Universal AC \/ DC Transmitter is a cutting-edge industrial \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e module that accurately measures and converts AC current and voltage signals into reliable unipolar or bipolar DC process outputs. Ideal for demanding automation, energy monitoring, and \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-control\"\u003eprocess control\u003c\/a\u003e applications, this transmitter supports input ranges up to 0-5 A AC RMS and 0-300 V AC RMS. Thus, the 4179, from \u003ca title=\"PR electronics 4179 Universal AC \/ DC Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4100\/universal-ac-dc-transmitter-4179\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, enables precise measurement of current transformers, supply lines, and power circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 0-5 AAC RMS range makes it possible to accurately measure a typical current transformer.\u003c\/li\u003e\n\u003cli\u003eThe 0-300 VAC RMS range allows accurate supply voltage monitoring.\u003c\/li\u003e\n\u003cli\u003eThe PR 4179 measures standard input ranges and can be freely configured to customer-defined input range. \u003c\/li\u003e\n\u003cli\u003eConverts narrow AC current \/ voltage inputs to wide bipolar or unipolar outputs, for example, 0-1 VAC RMS input = ±10 volt or 4-20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.\u003c\/li\u003e\n\u003cli\u003eConfigurable input limits control the output value for safety improvements.\u003c\/li\u003e\n\u003cli\u003eThe 4179 Universal AC \/ DC Transmitter provides the required failure data (SFF and PFDAVG) for SIL 2 applications as per \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eFailure rates for PR 4179 correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4179 Universal AC \/ DC Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith universal power supply compatibility (21.6-253 VAC \/ 19.2-300 VDC) and a response time of less than 0.75 seconds, the PR 4179 Universal AC \/ DC Transmitter delivers fast, accurate \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal conversion\u003c\/a\u003e with better than 0.3 % accuracy. Its flexible output configuration includes active or passive current outputs, thus enabling seamless integration into PLCs, DCS and \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\" title=\"Data Logging and Acquisition\"\u003edata acquisition\u003c\/a\u003e systems.\u003c\/p\u003e\n\u003cp\u003eIdeal for industrial immunity, the 4179 meets \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 recommendations, providing excellent noise rejection as well as reliable detection of input errors in harsh EMC environments. Robust 3-port galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (2.3 kVAC) protects equipment and also ensures signal integrity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe latest analog and digital techniques obtain maximum accuracy and immunity to interference.\u003c\/li\u003e\n\u003cli\u003ePossibility of output safety feedback by selecting S4-20 mA output.\u003c\/li\u003e\n\u003cli\u003eThe current output can drive up to 800 Ohms, with an adjustable response time of 0.0-60.0 seconds.\u003c\/li\u003e\n\u003cli\u003eExceptional mA output load stability of \u0026lt;0.001% of span \/ 100 Ohm.\u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE21 recommendations, thus ensuring high accuracy in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.\u003c\/li\u003e\n\u003cli\u003eTested to a high 2.3 kVAC, 3-port galvanic isolation level.\u003c\/li\u003e\n\u003cli\u003eExcellent signal to noise ratio of \u0026gt; 60 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration, process monitoring, and diagnostics are easily achieved via the detachable \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e display, while advanced safety features support SIL 2 and PL \"d\" applications. Whether monitoring AC power systems, converting sensor outputs, or driving control loops, the PR 4179 enhances precision, reliability, and operational uptime in industrial automation networks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVery low power consumption means units can mount side by side without an air gap – even at 140˚F (60˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eConfiguration, monitoring, 2-point process calibration, and more are available using PR's 4500 series of detachable displays.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4179-universal-ac-dc-transmitter-pr-electronics-universal-power-supply-monitoring-process-solutions-psc-texas.jpg?v=1769095976\" alt=\"PR-4179-universal-ac-dc-transmitter-pr-electronics-universal-power-supply-monitoring-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369812611,"sku":"4179","price":272.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4179-Universal-AC-DC-Transmitter-PR-electronics-power-supply-converter-process-solutions-corp-psc-texas.jpg?v=1769095994"},{"product_id":"pr-4184-universal-unipolar-bipolar-signal-transmitter","title":"PR 4184 Universal Unipolar \/ Bipolar Signal Transmitter","description":"\u003cp\u003eThe PR 4184 Universal Unipolar \/ Bipolar Signal Transmitter is an industrial \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e solution that offers precise DC voltage and current measurement and conversion across automation, \u003ca title=\"Automation Controllers\" href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\"\u003eprocess control\u003c\/a\u003e, and instrumentation systems. This multifunctional transmitter handles DC inputs up to ±300 V and ±100 mA, with programmable spans as small as 25 mV or 0.5 mA. Thus, the 4184, from \u003ca title=\"PR electronics 4184 Universal Unipolar \/ Bipolar Signal Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4100\/universal-uni-bipolar-signal-transmitter-4184\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for torque, \u003ca title=\"LVDT Position Sensors\" href=\"https:\/\/www.psctexas.shop\/collections\/position-sensors\"\u003eposition\u003c\/a\u003e, acceleration, current sensors, and potentiometer signal applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast \u0026lt; 20 ms response time for measuring signals from torque, position, current, \u0026amp; acceleration sensors.\u003c\/li\u003e\n\u003cli\u003eUser configurable bipolar or unipolar I\/O means the PR 4184 is suitable for nearly any DC voltage or current conversion. \u003c\/li\u003e\n\u003cli\u003eFreely programmable between ±300 VDC and ±100 mA.\u003c\/li\u003e\n\u003cli\u003eThe excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.\u003c\/li\u003e\n\u003cli\u003eConverts narrow bipolar inputs to wide bipolar or unipolar outputs, for example, ±1 volt input = ±10 volt or 4-20 mA output.\u003c\/li\u003e\n\u003cli\u003eConfigurable input limits control the output value for safety improvements. \u003c\/li\u003e\n\u003cli\u003e±20 VDC buffered voltage output for controlling devices like the PVG 32 \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalve\u003c\/a\u003e (6-18 VDC).\u003c\/li\u003e\n\u003cli\u003eThe 4184 provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL 2 applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the PR 4184 \u003cmeta charset=\"utf-8\"\u003eUniversal Unipolar \/ Bipolar Signal Transmitter correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4184 Universal Unipolar \/ Bipolar Signal Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing programmable unipolar and bipolar I\/O, the PR 4184 \u003cmeta charset=\"utf-8\"\u003eUniversal Unipolar \/ Bipolar Signal Transmitter converts narrow input ranges into wide standard outputs such as 4-20 mA, ±10 V, or custom ranges to meet system requirements. With a fast response time of \u0026lt; 20 ms and excellent accuracy better than 0.05%, this transmitter ensures reliable signal integrity for PLCs, DCS, recorders, and control loops.\u003c\/p\u003e\n\u003cp\u003eBuilt for industrial environments, the PR 4184 has universal AC\/DC power compatibility (21.6-253 VAC \/ 19.2-300 VDC) and robust 3-port galvanic \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (2.3 kVAC) to protect against electrical noise. It supports \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 and NE43 recommendations for EMC performance and sensor error detection, and meets SIL 2\/PL \"d\" safety requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe latest analog and digital techniques obtain maximum accuracy and immunity to interference.\u003c\/li\u003e\n\u003cli\u003ePossibility of output safety readback by selecting S4-20 mA output.\u003c\/li\u003e\n\u003cli\u003eThe current output can drive up to 1000 Ohms, with an adjustable response time of 0.0-60.0 seconds.\u003c\/li\u003e\n\u003cli\u003eExceptional mA output load stability of \u0026lt; 0.001% of span \/ 100 Ohm.\u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE21 recommendations, thus ensuring high accuracy in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eMeets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.\u003c\/li\u003e\n\u003cli\u003eTested to a high 2.3 kVAC, 3-port galvanic isolation level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple with the detachable \u003cmeta charset=\"utf-8\"\u003e\u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e series display, thus enabling easy calibration and monitoring without additional tools. Whether scaling sensor outputs or isolating critical signals, the PR 4184 delivers precision, safety, and versatility in demanding automation environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVery low power consumption means units can mount side by side without an air gap – even at 140˚F (60˚C) ambient temperature.\u003c\/li\u003e\n\u003cli\u003eConfiguration, monitoring, 2-point process calibration, and more via PR's 4500 series of detachable displays.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4184-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-industrial-signal-transmitter-automation-control-process-solutions-corp-psc-texas.jpg?v=1769099934\" alt=\"PR-4184-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-industrial-signal-transmitter-automation-control-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369845379,"sku":"4184","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4184-Universal-Unipolar-Bipolar-Signal-Transmitter-PR-electronics-universal-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769100268"},{"product_id":"pr-4222-universal-if-converter","title":"PR 4222 Universal I\/f Converter","description":"\u003cp\u003eThe PR 4222 Universal I\/f Converter is a robust industrial \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal converter\u003c\/a\u003e that transforms a wide range of analog sensor inputs into reliable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/frequency-and-pulse\" title=\"Frequency and Pulse Signal Devices\"\u003efrequency\u003c\/a\u003e outputs for process control, automation, and monitoring systems. It supports inputs from RTDs, thermocouples (TC), resistance (Ohm), potentiometers, as well as mA and voltage signals. Thus, the \u003cmeta charset=\"utf-8\"\u003e4222, from \u003ca rel=\"noopener\" title=\"PR electronics 4222 Universal I\/f Converter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/4200\/universal-i-f-converter-4222\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is highly adaptable for linear measurement and signal processing applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable via detachable display front (\u003ca title=\"PR electronics 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e series).\u003c\/li\u003e\n\u003cli\u003eFeatures process calibration, signal simulation, password protection, error diagnostics, and selection of help text in several languages.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a frequency signal, for example, from solenoids and butterfly \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003ePower supply and \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003esignal isolator\u003c\/a\u003e for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control by way of a frequency signal transmitted to, for example, a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLC\u003c\/a\u003e or a process computer.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation and conversion of analog signals to frequency signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 4222 Universal I\/f Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe PR 4222 Universal I\/f Converter has the capability to generate frequency outputs from 0 to 25,000 Hz in NPN, PNP, or TTL formats. Thus, the 4222 enables seamless integration with PLCs, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\" title=\"Data Logging and Acquisition\"\u003edata acquisition\u003c\/a\u003e systems, and process computers that rely on frequency-based signal processing. Its universal AC\/DC power supply range and compact design allow for flexible installation across diverse industrial environments. Continuous stored data checks and status indication via a front LED ensure operational reliability, while 3-port galvanic isolation (2.3 kVAC) delivers excellent noise immunity and signal integrity in harsh environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the 4222 is used in combination with the PR 4500 display \/ programming fronts, all operational parameters can adjust to suit any application. \u003c\/li\u003e\n\u003cli\u003eAs the PR 4222 features electronic hardware switches, it isn't necessary to open the device for setting of DIP switches.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e3-port 2.3 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThe PR 4222 Universal I\/f Converter is compatible with a detachable PR 4500 series display for easy programming, process calibration, signal simulation and diagnostics without opening the unit, thus enhancing safety and convenience for technicians. Ideal for applications like \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e linearization, resistance-to-frequency conversion, and analog to frequency signal isolation, the PR 4222 is a versatile choice for industrial automation and control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM Approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous locations\u003c\/a\u003e: Nonincendive for Class I, Division 2, Groups A, B, C, and D Hazardous (Classified) Indoor Locations with a T5 temperature classification; and Nonincendive for Class I, Division 2, Group IIC Hazardous (Classified) Indoor Locations with a T5 temperature classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4222-universal-i-f-converter-pr-electronics-industrial-frequency-conversion-signal-transmitter-process-solutions-psc-texas.jpg?v=1769103344\" alt=\"PR-4222-universal-i-f-converter-pr-electronics-industrial-frequency-conversion-signal-transmitter-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878369943683,"sku":"4222","price":498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-4222-universal-i-f-converter-pr-electronics-frequency-converter-process-solutions-corp-psc-texas.jpg?v=1769103360"},{"product_id":"pr-5114a-programmable-transmitter","title":"PR 5114A Programmable Transmitter","description":"\u003cp\u003eThe PR 5114A Programmable Transmitter is a versatile and industrial-grade \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for precision measurement and control in process \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003eautomation systems\u003c\/a\u003e. With jumper-selectable inputs for RTD, thermocouple (TC), mV, linear resistance, mA, and voltage signals, the 5114A, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/5100\/programmable-transmitter-5114a\/\" title=\"PR electronics 5114A Programmable Transmitter\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, adapts to multiple sensor types and signal sources, thus reducing the need for separate devices and simplifying installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5114 Programmable Transmitter can configure using the \u003ca title=\"PR electronics PReset Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset software\u003c\/a\u003e and the PR 5909 Loop Link communications unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5114A Programmable Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing 3-port galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e at 3.75 kVAC, the PR 5114A Programmable Transmitter ensures electrical separation between inputs, outputs, and power circuits. Thus, the 5114A enhances system safety and protecting sensitive control equipment from interference. Furthermore, it supports both current and voltage outputs and delivers a robust universal power supply range, making it suitable for global industrial applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJumper selectable inputs for current\/voltage or temperature.\u003c\/li\u003e\n\u003cli\u003eProgrammable current (0-100 mA) and voltage (0-250 VDC) inputs.\u003c\/li\u003e\n\u003cli\u003eLinearized, electronic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e measurement.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation, for example, from solenoids and butterfly \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e17.1 VDC loop and 2.5 VDC potentiometer supplies.\u003c\/li\u003e\n\u003cli\u003eAutomatic 4- \/ 3-wire or programmable 2-wire cable compensation.\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor error detection including \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE43.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eThis programmable transmitter can configure using PReset software and a Loop Link communications interface, thus providing flexibility and precision tuning for specific project requirements. Applications include linearized temperature measurement, resistance conversion for position or valve feedback, as well as accurate analog signal transmission for process control loops. In addition, features include automatic cable compensation, configurable sensor error detection (including NAMUR NE43 compliance), and loop and potentiometer power supplies. Compact and DIN-rail mountable, the PR 5114A Programmable Transmitter delivers high performance, adaptability, and dependable signal fidelity for demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eActive or Passive current output and selectable voltage output.\u003c\/li\u003e\n\u003cli\u003eSeparation of circuits in PELV\/SELV installations.\u003c\/li\u003e\n\u003cli\u003eThe PR 5114A features approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5114A-Programmable-Transmitter-PR-electronics-universal-temperature-transmitter-process-solutions-corp-psc-texas.jpg?v=1769530021\" alt=\"PR-5114A-Programmable-Transmitter-PR-electronics-universal-temperature-transmitter-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5114AA: 1-Channel","offer_id":46406354796675,"sku":"5114AA","price":487.0,"currency_code":"USD","in_stock":true},{"title":"5114AB: 2-Channel","offer_id":46406354829443,"sku":"5114AB","price":849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5114A-Programmable-Transmitter-PR-electronics-industrial-temperature-transmitter-thermocouples-ma-rtd-process-solutions-corp-psc-texas.jpg?v=1769530044"},{"product_id":"pr-5115a-signal-calculator","title":"PR 5115A Signal Calculator","description":"\u003cp\u003eThe PR 5115A Signal Calculator is a versatile, industrial-grade signal processing module that enhances automation and measurement systems by combining precision \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e with programmable arithmetic functions. The 5115A multifunctional signal calculator, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/5100\/signal-calculator-5115a\/\" title=\"PR electronics 5115A Signal Calculator\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports redundant measurement of two input signals, allowing automatic switch-over if a primary sensor fails. Thus, the PR 5115A is ideal for critical temperature or process monitoring applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing universal input compatibility for RTD, thermocouple (TC), ohm, mV, mA, and voltage signals, the PR 5115A enables wide-ranging deployment across industrial environments. Its programmable arithmetic capabilities, for example, addition, subtraction, multiplication, and division, allow complex operations such as differential and average signal calculations, making it perfect for advanced control strategies.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRedundancy measurement of \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e by means of two sensors, where the secondary sensor takes over the measurement when a sensor error occurs on the primary sensor.\u003c\/li\u003e\n\u003cli\u003eDuplication of the input signal, for example, from a temperature sensor or an analog process signal to two separate analog outputs.\u003c\/li\u003e\n\u003cli\u003eSignal calculator with four arithmetical operations: addition, subtraction, multiplication, as well as division. \u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eExample\u003c\/em\u003e: Differential measurement: (Input 1 * K1) - (Input 2 * K2) + K4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eExample\u003c\/em\u003e: Average measurement: (Input 1 * 0.5) + (Input 2 * 0.5) + K4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eExample\u003c\/em\u003e: Different functions on the outputs: Output 1 = input 1 - input 2, and Output 2 = input 1 + input 2.\u003c\/li\u003e\n\u003cli\u003eIn addition, the 5115A acts as a \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply Devices\"\u003epower supply\u003c\/a\u003e for 2-wire transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5115A Signal Calculator from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith great durability, this signal calculator features five-port galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e (3.75 kVAC) to protect equipment from electrical noise and interference, thus ensuring stable and accurate output. Configuration is fast and intuitive using \u003ca title=\"PR electronics PReset Software\" href=\"https:\/\/www.prelectronics.com\/downloads\/software\/preset-software\/\" target=\"_blank\"\u003ePReset software\u003c\/a\u003e and PR 5909 Loop Link communications. A bright green LED clearly indicates normal operation, sensor error, or functional fault status.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 5115A to a specific application using the configuration program PReset.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation, sensor error on each sensor, as well as functional error.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital stored data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e5-port 3.75 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eCompact, DIN-rail mountable construction allows installation of up to 42 units per meter, thus optimizing cabinet space in high-density installations. With universal AC\/DC power and advanced diagnostics, the PR 5115A provides reliable, flexible signal math and conditioning for demanding industrial automation, monitoring, and control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan mount vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eAs the devices can mount without any distance between neighboring units, up to 42 devices can mount per meter.\u003c\/li\u003e\n\u003cli\u003eThe PR 5115A features approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5115A-Signal-Calculator-PR-electronics-rtd-thermocouple-temperature-calculator-temperature-transmitter-process-solutions-psc-texas.jpg?v=1769531475\" alt=\"PR-5115A-Signal-Calculator-PR-electronics-rtd-thermocouple-temperature-calculator-temperature-transmitter-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878370009219,"sku":"5115A","price":908.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5115-A-Signal-Calculator-PR-electronics-temperature-calculator-for-process-automation-psc-texas.jpg?v=1769531493"},{"product_id":"pr-5116-programmable-transmitter","title":"PR 5116 Programmable Transmitter","description":"\u003cp\u003eThe PR 5116 Programmable Transmitter is a high-performance, multifunctional \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal transmitter\u003c\/a\u003e for industrial process automation, monitoring, and control applications. Featuring universal input compatibility for RTD, thermocouple (TC), mV, ohm, potentiometer, mA, and voltage signals, the 5116 Series, from \u003ca title=\"PR electronics 5116 Programmable Transmitter\" href=\"https:\/\/www.prelectronics.com\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, consolidates multiple sensor types into one versatile device, thus reducing inventory and installation complexity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized, electronic temperature measurement with RTD or TC sensor.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current \/ voltage signal, for example, from solenoids and butterfly valves or linear movements with attached potentiometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply\"\u003ePower supply\u003c\/a\u003e and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProcess control with 2 potential-free relay contacts which can configure for advanced functions.\u003c\/li\u003e\n\u003cli\u003eGalvanic separation of analog signals and measurement of floating signals.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5116A Programmable Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/5100\/programmable-transmitter-5116a\/\" target=\"_blank\"\u003ePR 5116A\u003c\/a\u003e Programmable Transmitter is suitable for industrial use in safe areas.\u003c\/li\u003e\n\u003cli\u003eThe \u003ca title=\"PR electronics 5116B Ex Programmable Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/5100\/programmable-transmitter-5116b\/\" target=\"_blank\"\u003ePR 5116B\u003c\/a\u003e Ex Programmable Transmitter is \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and features ATEX and FM approval.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 5116 Programmable Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eWith both current (0-20 mA) and voltage (0-10 VDC) outputs, plus two configurable relay outputs, the PR 5116 Programmable Transmitter gives process engineers extensive control options. The transmitter’s 3-port galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e (3.75 kVAC) enhances electrical safety, minimizes noise interference, and also protects downstream control systems against signal distortion. Universal AC\/DC power compatibility provides installation flexibility across global facilities, while DIN-rail mounting maximizes cabinet space efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds users can program the PR 5116 Series to suit any specific application.\u003c\/li\u003e\n\u003cli\u003eBy way of the front push-button, the input can calibrate to the exact span of the process.\u003c\/li\u003e\n\u003cli\u003eZero drift on the process signal can adjust by a single press of the front button.\u003c\/li\u003e\n\u003cli\u003eA green front LED indicates normal operation and malfunction.\u003c\/li\u003e\n\u003cli\u003eA yellow LED is ON for each active output relay.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003e3-port 3.75 kVAC galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eProgramming the PR 5116 Series is fast and intuitive. Users can configure input spans and output behavior via the front push-button interface, including zero-drift adjustment, or use Loop Link communications interface for advanced setup. A front LED panel clearly indicates operating status as well as relay activity for easy diagnostics. Applications include linearized temperature measurement, resistance signal conversion from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e and position sensors, two-wire transmitter power and signal isolation, and process control with configurable relay functions. The PR 5116 Programmable Transmitter delivers dependable accuracy (± 0.05%) in addition to rugged reliability for the most demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 5116 Series can mount vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eAs the 5116 can mount without any distance between neighboring units, up to 42 devices can mount per meter.\u003c\/li\u003e\n\u003cli\u003eThe PR 5116 Programmable Transmitter \u003cmeta charset=\"utf-8\"\u003efeatures approval for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5116-Programmable-Transmitter-PR-electronics-wiring-diagram-multifunctional-automation-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769547399\" alt=\"PR-5116-Programmable-Transmitter-PR-electronics-wiring-diagram-multifunctional-automation-signal-transmitter-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"5116A","offer_id":46420619427971,"sku":"5116A","price":568.0,"currency_code":"USD","in_stock":true},{"title":"5116B: Ex version","offer_id":46420619460739,"sku":"5116B","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-5116-Programmable-Transmitter-PR-electronics-thermocouple-valve-signal-transmitter-process-solutions-corp-psc-texas.jpg?v=1769549147"},{"product_id":"pr-9116-universal-converter","title":"PR 9116 Universal Converter","description":"\u003cp\u003eThe PR 9116 Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for industrial process control and automation. The 9116, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eModels in the 9116 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9116A Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/9100\/universal-converter-9116a\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eModel \u003ca title=\"PR electronics 9116B Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116 Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116 features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116 Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Series has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116 Series correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutio.jpg?v=1770654546\" alt=\"PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483617411,"sku":"9116A1","price":543.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483650179,"sku":"9116A1-U9","price":554.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483682947,"sku":"9116A2","price":550.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483715715,"sku":"9116A2-U9","price":557.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483748483,"sku":"9116B1","price":570.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483781251,"sku":"9116B1-U9","price":579.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483814019,"sku":"9116B2","price":577.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483846787,"sku":"9116B2-U9","price":583.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-Signal-Converter-Universal-Transmitter-Temperature-Voltage-Linear-Resistance-Process-Solutions-Texas.jpg?v=1770655699"},{"product_id":"pr-9116a-emp-universal-converter-emphasis-assessed","title":"PR 9116-EMP Universal Converter, EMPHASIS Assessed","description":"\u003cp\u003eThe PR 9116-EMP Universal Converter is a high-performance \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e device that's EMPHASIS assessed for nuclear applications. The 9116-EMP, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\" title=\"Power and Supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\" title=\"PR 4500 Series Programming Interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eModels in the 9116-EMP are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/9100\/universal-converter-9116a-emp\/\" title=\"PR electronics 9116A-EMP Universal Converter\" target=\"_blank\"\u003ePR 9116A-EMP\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eModel \u003ca rel=\"noopener\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b-emp\/\" title=\"PR electronics 9116B-EMP Ex Universal Converter\" target=\"_blank\"\u003ePR 9116B-EMP\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116-EMP Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116-EMP features robust galvanic \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116-EMP Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116-EMP has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca rel=\"noopener\" title=\"International Electrotechnical Commission\" href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116-EMP correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116-EMP Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas.jpg?v=1770658616\" alt=\"PR-9116-EMP-Universal-Converter-PR-electronics-PR9116-EMP-9116B-EMP-9116A-EMP-EMPHASIS-Assessed-Signal-Converter-Nuclear-Power-Intrinsic-Safety-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9116A-EMP: Safe Area; Zone 2 \/ Class 1; Div 2; Groups A B C D \/ 1: Uo 28 VDC","offer_id":46575613575299,"sku":"9116A1-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116A-EMP: Safe Area; Zone 2 \/ Class 1; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC","offer_id":46575613608067,"sku":"9116A2-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116B-EMP: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC","offer_id":46575613640835,"sku":"9116B1-EMP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"9116B-EMP: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC","offer_id":46575613673603,"sku":"9116B2-EMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-EMP-Universal-Converter-PR-electronics-PR-9116A-EMP-Signal-Transmitter-EMPHASIS-Assessed-Nuclear-Power-Signal-Converter-Process-Solutions-Corp-PSC-Texas.jpg?v=1770659390"}],"url":"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices.oembed?page=2","provider":"Process Solutions Corp.","version":"1.0","type":"link"}