{"product_id":"blitzductor-surge-protection-spd","title":"BLITZDUCTOR, Surge Protection SPD","description":"The pluggable, DIN rail mounted surge protection devices of the BLITZDUCTORconnect and BLITZDUCTOR SP\/XT\/XTU series, from \u003ca href=\"https:\/\/psctexas.com\/brand\/dehn\/\"\u003eDEHN\u003c\/a\u003e, can be universally used for protecting measuring and control circuits as well as bus and telecommunication systems. \u003ch3\u003eBLITZDUCTOR CT - Base Parts\u003c\/h3\u003e \u003ch5\u003e919506 \/ BCT BAS\u003c\/h5\u003e BLITZDUCTOR CT base part for use as universal feed-through terminal for supporting the SPD module without signal interruption. The SPD module is safely earthed by the supporting foot of the DIN rail with a snap-on device. Allows for direct or indirect shied earthing due to insert for gas discharge tubes. \u003cul\u003e \u003cli\u003euniversal device for all types of SPD modules\u003c\/li\u003e \u003cli\u003eplug-in and removal without signal interruption\u003c\/li\u003e \u003cli\u003einsert for indirect shield earthing\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e919620 \/ BCT MOD BE 5\u003c\/h5\u003e Combined lightning current and surge arrester module for protecting 2 single wires with common reference potential as well as unbalanced interfaces. Two upstream protective stages of the gas discharge tube minimize the decoupling impedance to the diode. \u003cul\u003e \u003cli\u003eoptimal protection\u003c\/li\u003e \u003cli\u003eminimal series impedance\u003c\/li\u003e \u003cli\u003efor use according to the lightning protection zones concept at \u003ca href=\"https:\/\/webstore.iec.ch\/publication\/6796\" target=\"_blank\" rel=\"nofollow noopener\"\u003eboundaries 0\u003csmall\u003eA\u003c\/small\u003e â 2 and higher\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBLITZDUCTOR XT Ex (i) Base Parts - Alapmodul\u003c\/h3\u003e \u003cul\u003e \u003cli\u003euniversal base part for protection modules of the BLITZDUCTOR XT Ex (i) series\u003c\/li\u003e \u003cli\u003eno signal disconnection if the protection module is removed\u003c\/li\u003e \u003cli\u003econnection of up to four lines\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e919507 \/ BCT BAS EX\u003c\/h5\u003e Base part for use as universal feed-through terminal for instrinsically safe circuits for supporting the SPD module without signal interruption. The SPD module is safely earthed by the supporting foot of the DIN rail by means of a snap-on device. Allows for direct and indirect shield earthing. \u003cul\u003e \u003cli\u003euniversal unit for all types of intrinsically safe SPD modules\u003c\/li\u003e \u003cli\u003eplug-in and removing without signal interruption\u003c\/li\u003e \u003cli\u003epatent insert for indirect shield earthing\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBLITZDUCTOR VT\u003c\/h3\u003e \u003cul\u003e \u003cli\u003ecost-effective protection of stranded signal lines\u003c\/li\u003e \u003cli\u003einterface-specific versions, e.g. RS485 or telecommunication systems\u003c\/li\u003e \u003cli\u003eversions for DC power supply systems and cathodic protection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e918410 \/ BVT ISDN\u003c\/h5\u003e For ISDN S\u003csmall\u003e0\u003c\/small\u003e buses with RJ45 connectors. The additional screw terminal connection at the protected output allows double wiring of the S\u003csmall\u003e0\u003c\/small\u003e bus (distribution function). Energy-coordinated ISDN four-wire protective circuit with additional protection for the remote power supply. \u003cul\u003e \u003cli\u003eRJ45 sockets\u003c\/li\u003e \u003cli\u003eadditional screw terminals for the ISDN lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zones concept at the \u003ca href=\"https:\/\/webstore.iec.ch\/publication\/6796\" target=\"_blank\" rel=\"nofollow noopener\"\u003eboundaries from 0\u003csmall\u003eB\u003c\/small\u003e â 2 and higher\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e918411 \/ BVT TC 1\u003c\/h5\u003e Energy-coordinated and leakage-current-free surge arrester for a\/b lines, ISDN U\u003csmall\u003ek0\u003c\/small\u003e or ADSL with RJ45 connections and additional screw terminals. Pinning of the RJ45 sockets is compatible with RJ11\/12. The parallel screw terminals are more robust than the RJ45 sockets and increase the total nominal discharge current to 10 kA. \u003cul\u003e \u003cli\u003epins of RJ sockets compatible with RJ12\u003c\/li\u003e \u003cli\u003eadditional screw terminals for a\/b lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eB\u003c\/small\u003e â 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cimg class=\"alignright wp-image-23128 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2023\/06\/BLITZDUCTOR-surge-protection-device-spd-surge-arrester-lighting-protector-electronics-process-solutions-corp.jpg\" alt=\"BLITZDUCTOR-surge-protection-device-spd-surge-arrester-lighting-protector-electronics-process-solutions-corp\" width=\"1000\" height=\"563\"\u003e\u003c\/h3\u003e \u003ch3\u003eBLITZDUCTOR XT - Surge Protection Modules\u003c\/h3\u003e \u003cb\u003eSPDs consist of a protection module and a base part\u003c\/b\u003e \u003cul\u003e \u003cli\u003evibration and shock-tested for safe operation\u003c\/li\u003e \u003cli\u003eall protection components integrated in the protection module\u003c\/li\u003e \u003cli\u003etwo universal base parts with \/ without signal disconnection\u003c\/li\u003e \u003cli\u003eminimum space requirements, 4 single lines or 2 pairs over a width of 12 mm\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eCombined lightning current and surge arrester\u003c\/b\u003e \u003cul\u003e \u003cli\u003emaximum discharge capacity for two-pole, three-pole or four-pole interfaces\u003c\/li\u003e \u003cli\u003ecapable of carrying lightning currents up to 10 kA (10\/350 Âµs)\u003c\/li\u003e \u003cli\u003elow voltage protection level, capable of protecting terminal equipment\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eWith integrated LifeCheck monitoring\u003c\/b\u003e \u003cul\u003e \u003cli\u003earrester testing during operation\u003c\/li\u003e \u003cli\u003edetection of pre-damaged arresters\u003c\/li\u003e \u003cli\u003ehigh signal availability thanks to preventive replacement of arresters\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920247 \/ BXT ML2 BD 180\u003c\/h5\u003e Space-saving combined lightning current and surge arrester module with RFID LifeCheck for protecting one pair of unearthed balanced interfaces. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC \/ SCM \/ MCM reader. \u003cul\u003e \u003cli\u003eLifeCheck SPD monitoring function\u003c\/li\u003e \u003cli\u003eoptimal protection of one pair\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920310 \/ BXT ML4 B 180\u003c\/h5\u003e Space-savings four-pole lightning current arrester module with RFID \u003ca href=\"https:\/\/psctexas.com\/product\/lifecheck\/\"\u003eLifeCheck\u003c\/a\u003e feature for almost all applications. For use in connection with downstream Type 2 - P1 surge arresters or combined lightning current and surge arresters with a lower or equal voltage level. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC \/ SCM \/ MCM reader. \u003cul\u003e \u003cli\u003eLifeCheck SPD monitoring function\u003c\/li\u003e \u003cli\u003efour-pole lightning equipotential bonding\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the \u003ca href=\"https:\/\/webstore.iec.ch\/publication\/6796\" target=\"_blank\" rel=\"nofollow noopener\"\u003eboundaries from 0\u003csmall\u003eA\u003c\/small\u003e â 1 and higher\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920324 \/ BXT ML4 BE 24\u003c\/h5\u003e Space-saving combined lightning current and surge arrester module with LifeCheck feature for protecting four single lines sharing a common reference potential as well as unbalanced interfaces. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC \/ SCM \/ MCM reader. \u003cul\u003e \u003cli\u003eLifeCheck SPD monitoring function\u003c\/li\u003e \u003cli\u003eoptimal protection of four single lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920336 \/ BXT ML4 BE 36\u003c\/h5\u003e Space-saving combined lightning current and surge arrester module with LifeCheck feature for protecting four single lines sharing a commonÂ reference potential as well as unbalanced interfaces. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC \/ SCM \/ MCM reader. \u003cul\u003e \u003cli\u003eLifeCheck SPD monitoring function\u003c\/li\u003e \u003cli\u003eoptimal protection of four single lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e â 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e919527 \/ BCT MOD ME 110\u003c\/h5\u003e Surge arrester module for protecting 2 single lines with common reference potential as well as unbalanced interfaces. Using powerful varistors no longer requires the decoupling to the gas discharge tube. \u003cul\u003e \u003cli\u003epowerful standard protection\u003c\/li\u003e \u003cli\u003eminimum series impedance\u003c\/li\u003e \u003cli\u003efor use according to the lightning protection zones concept at boundaries 0\u003csmall\u003eB\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e919627 \/ BCT MOD BE 110\u003c\/h5\u003e Combined lightning current and surge arrester module for protecting 2 single wires with common reference potential as well as unbalanced interfaces. \u003cul\u003e \u003cli\u003eoptimal protection\u003c\/li\u003e \u003cli\u003eminimal series impedance\u003c\/li\u003e \u003cli\u003efor use according to the lightning protection zones concept at boundaries 0\u003csmall\u003eA\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBLITZDUCTOR XTU - Surge Protection Modules with RFID LifeCheck\u003c\/h3\u003e \u003cb\u003eCombined lightning current and surge arrester\u003c\/b\u003e \u003cul\u003e \u003cli\u003emaximum discharge capacity for balanced data interfaces\u003c\/li\u003e \u003cli\u003ecapable of carrying lightning currents up to 10 kA (10\/350 Âµs)\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e â 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eWith actiVsense technology\u003c\/b\u003e \u003cul\u003e \u003cli\u003eautomatically detects the signal voltage ranging from 0 to 180 V\u003c\/li\u003e \u003cli\u003eoptimally adapts the voltage protection level to the currently applied signal\u003c\/li\u003e \u003cli\u003ecapable of protecting terminal equipment due to adapted voltage protection level\u003c\/li\u003e \u003cli\u003eone arrester type for two different data interfaces\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eIntegrated RFID LifeCheck monitoring function\u003c\/b\u003e \u003cul\u003e \u003cli\u003earresters can be tested without downtime\u003c\/li\u003e \u003cli\u003edetection of pre-damaged arresters\u003c\/li\u003e \u003cli\u003ehigh signal availability due to preventive replacement of arresters\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eArrester consists of a protection module and a base part\u003c\/b\u003e \u003cul\u003e \u003cli\u003efor DIN rail mounting with a standard base part\u003c\/li\u003e \u003cli\u003eeasy replacement of protection modules\u003c\/li\u003e \u003cli\u003evibration and shock-tested for safe operation\u003c\/li\u003e \u003cli\u003etwo universal base parts with \/ without signal disconnection\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920349 \/Â BXTU ML4 BD 0-180\u003c\/h5\u003e Space-saving combined lightning current and surge arrester module with actiVsense technology and RFID LifeCheck for protecting two pairs (same or different operating voltage) of balanced interfaces with galvanic isolation. Automatically detects the operating voltage of the useful signal and optimally adapts the voltage protection level to it. \u003cul\u003e \u003cli\u003euniversal voltage type with actiVsense technology\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e â 2 and higher\u003c\/li\u003e \u003cli\u003ewith integrated LifeCheck monitoring\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e920371 \/ BXT ML4 BD HF 5\u003c\/h5\u003e Space-saving combined lightning current and surge arrester module with RFID LifeCheck for protecting two pairs of unearthed high-frequency bus systems or two-wire video transmission systems. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC \/ SCM \/ MCM reader. \u003cul\u003e \u003cli\u003eLifeCheck SPD monitoring function\u003c\/li\u003e \u003cli\u003eminimal signal interference\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e https:\/\/www.youtube.com\/watch?v=QoXtYZzZzf0 \u003ch3\u003eBLITZDUCTOR SP\u003c\/h3\u003e \u003cb\u003eUniversal surge arrester\u003c\/b\u003e \u003cul\u003e \u003cli\u003euniversal surge arrester for two-pole, three-pole or four-pole interfaces\u003c\/li\u003e \u003cli\u003ehigh discharge capacity up to 20 kA (8\/20 Âµs)\u003c\/li\u003e \u003cli\u003elow voltage protection level, capable of protecting terminal equipment\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eArrester consists of a protection module and a base part\u003c\/b\u003e \u003cul\u003e \u003cli\u003eeasy replacement of protection modules\u003c\/li\u003e \u003cli\u003eall protection components integrated in the protection module\u003c\/li\u003e \u003cli\u003etwo universal base parts with or without signal disconnection\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eFunctional and attractive design\u003c\/b\u003e \u003cul\u003e \u003cli\u003eDIN rail mounted device with integrated earthing\u003c\/li\u003e \u003cli\u003eminimum space requirements, four single lines or two pairs over a width 12 mm\u003c\/li\u003e \u003cli\u003evibration and shock-tested for safe operation\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e926324 \/ BSP M4 BE 24\u003c\/h5\u003e Space-saving surge arrester module for protecting four single lines sharing a common reference potential and unbalanced interfaces. \u003cul\u003e \u003cli\u003ehigh degree of protection for four single lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eB\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e926344 \/ BSP M4 BD 24\u003c\/h5\u003e Space-saving surge arrester module for protecting two pairs of balanced interfaces with galvanic isolation. \u003cul\u003e \u003cli\u003ehigh degree of protection for two pairs\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eB\u003c\/small\u003e - 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e926370 \/ BSP M4 BE HF 5\u003c\/h5\u003e Space-saving surge arrester module for protecting four single lines sharing a common reference potential and high-frequency transmissions without galvanic isolation. \u003cul\u003e \u003cli\u003ehigh degree of protection for four single lines\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0B â2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBLITZDUCTORconnect â Modular Surge Protection Device\u003c\/h3\u003e \u003cb\u003eUniversal lightning current and surge arrester\u003c\/b\u003e \u003cul\u003e \u003cli\u003efor protecting measuring and control circuits, bus and telecommunication systems\u003c\/li\u003e \u003cli\u003ehigh total discharge capacity of 3 kA (10\/350 Âµs), 10 kA (8\/20 Âµs)\u003c\/li\u003e \u003cli\u003emaximum impulse current carrying capability (8\/20 Âµs) I\u003csmall\u003emax\u003c\/small\u003e up to 20 kA\u003c\/li\u003e \u003cli\u003elow voltage protection level, also capable of protecting terminal equipment\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eArrester consisting of a module and base part\u003c\/b\u003e \u003cul\u003e \u003cli\u003efast and simple cable connection thanks to push-in connection terminals\u003c\/li\u003e \u003cli\u003eall protection components integrated in the module\u003c\/li\u003e \u003cli\u003esecR release buttons on both sides for safe module replacement\u003c\/li\u003e \u003cli\u003ehigh system availability thanks to fail-safe performance\u003c\/li\u003e \u003c\/ul\u003e \u003cb\u003eFunction-optimised design with a width of 6 mm \u003c\/b\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"https:\/\/psctexas.com\/product\/lifecheck\/\"\u003eLifeCheck\u003c\/a\u003e and visual status indication integrated in the module\u003c\/li\u003e \u003cli\u003esimple remote signaling of the status with the help of an optional remote signaling unit\u003c\/li\u003e \u003cli\u003etool-free signal disconnection for maintenance purposes\u003c\/li\u003e \u003cli\u003evibration and shock-tested for safe operation\u003c\/li\u003e \u003c\/ul\u003e \u003ch5\u003e927271 - BCO ML2 BD HF 5\u003c\/h5\u003e Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces. With signal disconnection for maintenance purposes. \u003cul\u003e \u003cli\u003elifeCheck arrester monitoring and integrated status indication\u003c\/li\u003e \u003cli\u003emodular two-pole arrester for optimal protection of one pair of high-frequency signal circuits\u003c\/li\u003e \u003cli\u003efor installation in conformity with the lightning protection zone concept at the boundaries from 0\u003csmall\u003eA\u003c\/small\u003e â 2 and higher\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eInstallation of the BLITZDUCTORconnect\u003c\/h3\u003e https:\/\/www.youtube.com\/watch?v=zhE_AY0Q9Hc","brand":"DEHN","offers":[{"title":"920310 - BXT ML4 B 180","offer_id":45878400876675,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"919506 - BCT BAS","offer_id":45878400909443,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"918411 - BVT TC 1","offer_id":45878400942211,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"918410 - BVT ISDN","offer_id":45878400974979,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"919620 - BCT MOD BE 5","offer_id":45878401007747,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"920349 -Â BXTU ML4 BD 0-180","offer_id":45878401040515,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"920336 - BXT ML4 BE 36","offer_id":45878401073283,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"927271 - BCO ML2 BD HF 5","offer_id":45878401106051,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"920324 - BXT ML4 BE 24","offer_id":45878401138819,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"919627 \/ BCT MOD BE 110","offer_id":45878401171587,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"926344 \/ BSP M4 BD 24","offer_id":45878401204355,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"919527 \/ BCT MOD ME 110","offer_id":45878401237123,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"920247 \/ BXT ML2 BD 180","offer_id":45878401269891,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"926324 \/ BSP M4 BE 24","offer_id":45878401302659,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"926370 \/ BSP M4 BE HF 5","offer_id":45878401335427,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"920371 \/ BXT ML4 BD HF 5","offer_id":45878401368195,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"919507 \/ BCT BAS EX","offer_id":45878401400963,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"910903 \/ LZC ME3D 24V","offer_id":45878401433731,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"910902","offer_id":45878401466499,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/blitzductor-surge-lightning-industrial-instrumentation-in-stock-spd-psc-texas.png?v=1763386050","url":"https:\/\/www.psctexas.shop\/products\/blitzductor-surge-protection-spd","provider":"Process Solutions Corp.","version":"1.0","type":"link"}