{"product_id":"cs50-non-incendive-pressure-transducer-50-30000-psi","title":"CS50 Non-Incendive Pressure Transducer, 50-30,000 PSI","description":"The CS50 Non-Incendive Pressure Transducer is a high strength \u003ca href=\"https:\/\/psctexas.com\/product-category\/pressure\/\"\u003epressure sensor\u003c\/a\u003e for use in \u003ca href=\"https:\/\/psctexas.com\/ul-standards-for-hazardous-location-industrial-instrumentation\/\"\u003eClass I, Division 2 hazardous locations\u003c\/a\u003e. The CS50 features an all welded \u003ca href=\"http:\/\/psctexas.com\/wetted-materials-options-for-pressure-sensors\/\"\u003estainless steel\u003c\/a\u003e construction, offering a minimum \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 rating\u003c\/a\u003e. A wide range of configurable options make the CS50 a versatile pressure transducer that's able to operate in some of the harshest conditions. The CS50 is an excellent solution for applications such as \u003ca href=\"https:\/\/psctexas.com\/category\/industries\/oil-and-energy\/\"\u003enatural gas compression\u003c\/a\u003e, \u003ca href=\"https:\/\/psctexas.com\/tag\/hydrogen-industrial-gas\/\"\u003ehydrogen compression and storage\u003c\/a\u003e, and process control instrumentation. Caution must be taken when installing and operating \u003ca href=\"https:\/\/psctexas.com\/product-tag\/hazloc-rated\/\"\u003ehazardous area instrumentation\u003c\/a\u003e. Please review the Non-Incendive Operating Instructions prior to installation. \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2, Groups A, B, C, D T4 approval\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003epressures from 50 to 30,000 PSI\u003c\/li\u003e \u003cli\u003esee \u003ca href=\"https:\/\/psctexas.com\/product\/cs51-non-incendive-low-pressure-transducer-core-sensors\/\"\u003emodel CS51\u003c\/a\u003e for pressures below 50 PSI\u003c\/li\u003e \u003cli\u003eone piece design\u003c\/li\u003e \u003cli\u003eno conduit installation required\u003c\/li\u003e \u003cli\u003eavailable with a \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast connection\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003eassembly in New Jersey, USA\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCS50 Non-incendive Pressure Transducer\u003c\/h3\u003e In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS50 Non-Incendive Pressure Transducer, from \u003ca href=\"https:\/\/psctexas.com\/brand\/core-sensors\/\"\u003eCore Sensors\u003c\/a\u003e, offers an integral \u003ca href=\"https:\/\/psctexas.com\/brand\/turck\/\"\u003eTurck\u003c\/a\u003e Minifast electrical connection. In combination with a CSA Division 2 Turck cordset and Lokfast Guard, there is no requirement for conduit to be installed over the cable.* This not only makes installation easy but also makes switching out sensors less cumbersome. We can supply all components as a complete package. Click here to learn more about the \u003ca href=\"http:\/\/psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\"\u003eTurck Minifast electrical connection here: psctexas.com\/turck-minifast-connection-for-class-1-div-2-hazardous-areas\/\u003c\/a\u003e *We recommend confirming hazardous location installation requirements with your local inspector as each installation is unique. \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003ePerformance\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eThermal\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eEnvironmental\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eAccuracy @ 77ËF (25ËC)\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% BFSL\u003c\/li\u003e \u003cli\u003eâ¤ Â±0.5% BFSL \u003csmall\u003e(\u0026gt;10,000 PSI)\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStability (1 Year)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.25% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003ePressure Cycles\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e100 million\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOverpressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e2X minimum\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eBurst Pressure\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5X or 60,000 PSI, \u003csmall\u003ewhichever is less\u003c\/small\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 176ËF\u003c\/li\u003e \u003cli\u003e-40 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOperating Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-4 to 176ËF\u003c\/li\u003e \u003cli\u003e-20 to 80ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eMedia Temperature \u003csmall\u003e(Electrical connection âFâ,Â DIN 43650-A)\u003c\/small\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 221ËF\u003c\/li\u003e \u003cli\u003e-40 to 105ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCompensated Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e32 to 131ËF\u003c\/li\u003e \u003cli\u003e0 to 55ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eStorage Temperature\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e-40 to 257ËF\u003c\/li\u003e \u003cli\u003e-40 to 125ËC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Zero\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eTC Span\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±1% of FS\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eEMI\/RFI Protection\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eYes\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"nofollow noopener\"\u003eIP Rating\u003c\/a\u003e\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP65 minimum\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eVibration\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10 g, 20 to 2000 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eShock\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003e100 g, 11 msec, 1\/2 sine\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"3\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAccuracy includes non-linearity, hysteresis and non-repeatability. \u003csup\u003e2\u003c\/sup\u003eIP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eElectrical Specifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth style=\"text-align: center;\"\u003eCurrent\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eVoltage\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eRatiometric\u003c\/th\u003e \u003cth style=\"text-align: center;\"\u003eLow Power\u003c\/th\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e4-20 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e20 mA, typical\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0-800 Ohms @ 10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~250 Hz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e1-5 V\u003c\/li\u003e \u003cli\u003e1-6 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e10-28 VDC\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-4.5 V ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 VDC Â±0.5 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e\u0026lt; 10 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003ctd valign='\"top'\u003e \u003cp style=\"text-align: left;\"\u003eOutputs\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e0.5-2.5 V non-ratiometric\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eExcitation\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e3-5 VDC unregulated\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eCurrent Consumption\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ 3 mA\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eOutput Load\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e5 K Ohms, min\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eFrequency Response (min)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003e~1 kHz\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eZero Offset (of FS)\u003c\/p\u003e \u003cul style=\"text-align: left;\"\u003e \u003cli\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"text-align: left;\"\u003eSpan Tolerance (of FS)\u003c\/p\u003e \u003cul\u003e \u003cli style=\"text-align: left;\"\u003eâ¤ Â±0.5% typical, Â±1% max\u003c\/li\u003e \u003c\/ul\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eHazardous Area Approvals and Certifications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCSA Class I, Division 2 Groups A,BC,D T4\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/webstore.ansi.org\/standards\/ul\/ul122701ed2017\" target=\"_blank\" rel=\"nofollow noopener\"\u003eANSI\/UL 122701 Single Seal\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/ww2.eagle.org\/en.html\" target=\"_blank\" rel=\"nofollow noopener\"\u003eABS (American Bureau of Shipping)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.trade.gov\/ce-marking\" target=\"_blank\" rel=\"nofollow noopener\"\u003eCE\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eConfiguration Guide\u003c\/h3\u003e \u003ca href=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\"\u003e\u003cimg class=\"aligncenter wp-image-23705 size-full\" src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2020\/07\/cs50-non-incendive-industrial-pressure-sensor-core-sensors-psc-texas-configuration.jpg\" alt=\"cs50-non-incendive-pressure-transducer-core-sensors-psc-texas-configuration\" width=\"1000\" height=\"367\"\u003e\u003c\/a\u003e \u003ch3\u003eCommon Uses of the CS50 Non-incendive Pressure Transducer\u003c\/h3\u003e \u003cul\u003e \u003cli\u003enatural gas compression\u003c\/li\u003e \u003cli\u003eoil exploration\u003c\/li\u003e \u003cli\u003eprocess controls\u003c\/li\u003e \u003cli\u003ehydrogen (316L SS only)\u003c\/li\u003e \u003c\/ul\u003e","brand":"Core Sensors","offers":[{"title":"Default Title","offer_id":45878377054339,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/cs-50-non-incendive-pressure-transducer-core-sensors-process-solutions-corp.png?v=1763385565","url":"https:\/\/www.psctexas.shop\/products\/cs50-non-incendive-pressure-transducer-50-30000-psi","provider":"Process Solutions Corp.","version":"1.0","type":"link"}