{"product_id":"pilotrek-w-200-non-contact-radar-level-transmitter","title":"PiloTREK W-200, Non-Contact Radar Level Transmitter","description":"\u003cul\u003e\n\u003cli\u003e1\", 1.5\" encapsulated horn antenna\u003c\/li\u003e\n\u003cli\u003eintegrated design with \u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\" target=\"_blank\" title=\"IP Rating for Industrial Instrumentation\" rel=\"noopener\"\u003eIP68 protection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003euser-friendly threshold management\u003c\/li\u003e\n\u003cli\u003eEx variant coming soon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNon-contact Radar Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe reflection of the millimeter-waves is highly dependent on the dielectric constant of the medium. Therefore, the measured medium's dielectric constant (ε\u003csmall\u003er\u003c\/small\u003e) must be over 1.9 for millimeter-wave level measurement. The measurement principle of a level transmitter with a millimeter-waves signal is based on measuring the reflection’s time of flight. The speed of propagation of millimeter-waves signals in the air, gases, and vacuum is almost constant regardless of temperature and medium pressure. So the measured distance does not depend on the physical parameters of the intermediate medium. The PiloTREK W–200 level transmitter is a continuous-wave frequency modulated radar (FMCW) operating at 80 GHz (W-band).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHigh Accuracy Microwave Level Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe most obvious advantages of 80 GHz radars over lower frequency (5-12 \u0026amp; 25 GHz) radars offer a smaller antenna size, better focus, and smaller beam angle. A portion of the millimeter-wave continuous wave energy radiated by the level transmitter antenna is reflected from the measured surface, depending on the material to be measured. The distance of the reflecting surface is calculated with high accuracy by the electronics from the frequency shift of the reflected signal and converted into a distance, level, or volume signal by the electronics.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDielectric Constant Values (ε\u003csmall\u003er\u003c\/small\u003e)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eButane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5-10\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCooking O\u003c\/strong\u003e\u003cstrong\u003eil\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLPG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6-1.9\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimestone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1-9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKerosene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8-2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAcetone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrude Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiesel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMethanol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasoline\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGlycol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsphalt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrobenzene\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClinker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4-3.6\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSulfuric Acid\u003c\/strong\u003e \u003cem\u003e(T=68˚F [20˚C])\u003c\/em\u003e\n\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eHART Enabled Multidrop Loop\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/pilotrek-w-200-nivelco-noncontact-radar-level-measurement-hart-communication-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana-300x145.jpg\" alt=\"pilotrek-w-200-nivelco-noncontact-radar-level-measurement-hart-communication-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003eMultiCONT multichannel process controllers process and display measurement data supplied by NIVELCO HART equipped transmitters in a Multidrop loop. Connected transmitters can be programmed through MultiCONT, and it can also perform data gathering duties. Processed data may be sent to a computer via RS485 and displayed in NIVISON. MultiCONT provides the means to optimize and configure measurements and display the echo maps of the particular installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBluetooth Enabled Level Transmitter\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/nivelco-tank-bluetooth-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-instrumentation-300x124.jpg\" alt=\"nivelco-tank-bluetooth-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-instrumentation\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003eInstruments with HART connectivity can be linked to a PC via \u003ca rel=\"noopener\" href=\"https:\/\/www.bluetooth.com\" target=\"_blank\"\u003eBluetooth\u003c\/a\u003e using a UNICOMM HART–USB-Bluetooth modem (SAT–504). The USB power bank connected to the UNICOMM modem can power the entire setup.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"nv-product-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e12 to 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–40 to 176 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Temperature\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–40 to 176 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Pressure\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e–14.5 to 43.5 psi (–0.1 to 0.3 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eMeasuring Range\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e0 to 98.5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eOutput\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e4 to 20 mA + HART, optional SPDT output, service interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e1\", 1.5\" BSP \/ NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIngress Protection\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003e\u003ca href=\"https:\/\/psctexas.com\/ip-rating-for-industrial-instrumentation\/\"\u003eIP68\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-scope\"\u003e\n\u003cth class=\"ng-binding\"\u003eApprovals\u003c\/th\u003e\n\u003ctd class=\"ng-binding\"\u003eATEX (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003ePiloTREK W-200 Level Transmitter Model Line Up\u003c\/h2\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/psctexas.com\/wp-content\/uploads\/2022\/11\/nivelco-tank-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-industrial-instrumentation.jpg\" alt=\"nivelco-tank-level-measurement-sensor-microwave-radar-noncontact-pilotrek-w200-process-solutions-industrial-instrumentation\" style=\"margin-top: 25px; margin-bottom: 25px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eCommon Level Measurement Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003elevel measurement of liquids, emulsions, and other chemicals up to 98.5 ft\u003c\/li\u003e\n\u003cli\u003emedium and large storage tanks or chemical tanks\u003c\/li\u003e\n\u003cli\u003emeasurement through a plastic tank wall\u003c\/li\u003e\n\u003cli\u003ematerial prone to vapor formation\u003c\/li\u003e\n\u003cli\u003eliquids with a gas cushion\u003c\/li\u003e\n\u003cli\u003esuitable for use in a vacuum\u003c\/li\u003e\n\u003cli\u003eopen channel flow measurement\u003c\/li\u003e\n\u003cli\u003erevenue water and wastewater industry\u003c\/li\u003e\n\u003cli\u003eenergy industry, oil and gas production\u003c\/li\u003e\n\u003cli\u003efood and beverage industry\u003c\/li\u003e\n\u003cli\u003epharmaceutical industry\u003c\/li\u003e\n\u003cli\u003echemical \/ petrochemical industry\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/psctexas.com\/product-tag\/marine-certified\/\"\u003emarine applications\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nivelco","offers":[{"title":"Default Title","offer_id":45878392586371,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/pilotrek-w-200-nivelco-noncontact-radar-level-measurement-microwave-sensor-level-tank-measurement-psc-texas-oklahoma-louisiana.png?v=1763385946","url":"https:\/\/www.psctexas.shop\/products\/pilotrek-w-200-non-contact-radar-level-transmitter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}