{"product_id":"pr-2261-mv-transmitter","title":"PR 2261 mV Transmitter","description":"\u003cp\u003eThe PR 2261 mV Transmitter is a versatile industrial millivolt to current\/voltage \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\" title=\"Signal Converters\"\u003esignal converter\u003c\/a\u003e that's ideal for precise measurement and control applications. The 2261, from \u003ca href=\"https:\/\/www.prelectronics.com\/products\/special-devices\/2200\/mv-transmitter-2261\/\" target=\"_blank\" title=\"PR electronics 2261 mV Transmitter\" rel=\"noopener\"\u003ePR electronics\u003c\/a\u003e, is capable of converting bipolar mV signals from strain gauges, load cells, and other low-level transducers into standard analog outputs. Furthermore, the PR 2261 supports \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioning\u003c\/a\u003e for weighing systems, \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel control\u003c\/a\u003e, tensile force measurement, tank filling\/draining, and general industrial automation tasks. Its front-programmable interface with a 3-digit LED display and push buttons makes calibration as well as configuration fast and intuitive.\u003c\/p\u003e\n\u003cp\u003eBuilt for industrial environments, the 2261 accepts programmable -40 to 100 mVDC input and can output either 0-20 mA or 0-10 VDC signals to \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS units, or \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/data-logging-and-acquisition\" title=\"Data Logging and Acquisition\"\u003edata acquisition\u003c\/a\u003e systems. A selectable NPN\/PNP digital input allows external taring functions, thus helping streamline load cell applications. Optional transducer power from 5-13 VDC is available, supporting multiple parallel load cells while a sense input compensates for cable resistance to ensure signal accuracy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA multifunction user interface consisting of three push buttons and a 3-digit LED display for programming.\u003c\/li\u003e\n\u003cli\u003eThe PR 2261 converts bipolar mV signals from transducers supplied directly by the device to standard current \/ voltage signals. \u003c\/li\u003e\n\u003cli\u003eThe 2261 mV Transmitter is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion \/ amplification etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 2261 mV Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eCompact yet robust, the PR 2261 offers a front error LED for quick fault identification and is compatible with standard 11-pole sockets adaptable for DIN-rail or panel mounting. Its flexible programming, reliable performance, and broad application range make the 2261 mV Transmitter an ideal choice for industrial signal conversion and process measurement systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFront error LED.\u003c\/li\u003e\n\u003cli\u003eThe analog input can be programmed for voltage in the range -40 to 100 mVDC.\u003c\/li\u003e\n\u003cli\u003eUsers can select either NPN or PNP for the digital signal.\u003c\/li\u003e\n\u003cli\u003eTaring can either be by way of the digital input or from the front interface.\u003c\/li\u003e\n\u003cli\u003eUsers can program the analog output to current in the range 0 to 20 mA as well as voltage in the range 0 to 10 VDC.\u003c\/li\u003e\n\u003cli\u003eUsers can program the transducer supply to 5 to 13 VDC from the front. \u003c\/li\u003e\n\u003cli\u003eUsers must ensure a maximum load of 230 mA (for example, 6 parallel 350 Ω load cells).\u003c\/li\u003e\n\u003cli\u003eSense input (with transducer supply used) for compensation for cable resistance to the transducer.\u003c\/li\u003e\n\u003cli\u003eMounting for a standard 11-pole socket which can adapt for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-2261-mv-transmitter-pr-electronics-millivolt-converter-signal-conditioning-module-process-solutions-psc-texas.jpg?v=1769011506\" alt=\"PR-2261-mv-transmitter-pr-electronics-millivolt-converter-signal-conditioning-module-process-solutions-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":46384510500995,"sku":"2261","price":563.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-2261-mV-Transmitter-PR-electronics-signal-converter-millivolt-process-solutions-corp-psc-texas.jpg?v=1769011530","url":"https:\/\/www.psctexas.shop\/products\/pr-2261-mv-transmitter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}