{"product_id":"pr-3333-pt100-temperature-converter","title":"PR 3333 Pt100 Temperature Converter","description":"\u003cp\u003eThe PR 3333 Pt100 Temperature Converter is a compact and reliable temperature \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal conditioner\u003c\/a\u003e for converting standard Pt100 RTD temperature sensor readings into a passive analog current signal for industrial process control and automation systems. Ideal for harsh environments, this loop-powered Pt100 \u003ca title=\"Temperature Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature-converters\"\u003etemperature converter\u003c\/a\u003e supports 2-, 3-, or 4-wire RTD configurations. Furthermore, the 3333, from \u003ca title=\"PR electronics 3333 Pt100 Temperature Converter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/3300\/pt100-converter-loop-powered-3333\/\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, delivers excellent conversion performance with accuracy better than 0.1 % of span and a high signal-to-noise ratio (\u0026gt; 60 dB).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PR 3333 is a Pt100 temperature converter which measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and also provides a passive analog current output signal.\u003c\/li\u003e\n\u003cli\u003eAll terminals feature protection against over-voltage, polarity, and short-circuit. \u003c\/li\u003e\n\u003cli\u003eThe device can mount in safe areas or in Zone 2 \/ Division 2 \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e and also features approval for \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\" title=\"Marine Certified Instrumentation\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 3333 Pt100 Temperature Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eFeaturing selectable fast (\u0026lt; 30 ms) or damped (300 ms) response times, the PR 3333 Pt100 Temperature Converter ensures both rapid reaction to temperature changes and noise-free outputs when necessary. Its versatile loop-powered design (3.3–35 VDC) eliminates the need for an external power supply, thus simplifying installation and reducing wiring complexity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexibly loop-powered by 3.3 to 35 VDC via connectors.\u003c\/li\u003e\n\u003cli\u003eExcellent conversion accuracy in all available ranges, better than 0.1% of span.\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 30 ms fast response time with simultaneous sensor error detection when selected.\u003c\/li\u003e\n\u003cli\u003eSelectable 300 ms response time when signal dampening is necessary.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, this device ensures top measurement performance in harsh EMC environments.\u003c\/li\u003e\n\u003cli\u003eThe PR 3333 meets the NAMUR NE43 standard defining out of range and sensor error output values.\u003c\/li\u003e\n\u003cli\u003eExcellent signal \/ noise ratio \u0026gt; 60 dB.\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range: \u003cmeta charset=\"utf-8\"\u003e-13 to 158˚F (-25 to 70˚C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eIdeal for industrial and hazardous installations, the PR 3333 meets NAMUR NE21 and NE43 standards for superior EMC immunity and sensor error handling. Furthermore, it features certification for Safe Areas as well as Zone 2\/Division 2 and marine applications. The slim 6.1 mm DIN-rail housing allows high-density mounting, up to 163 units per meter, thus maximizing panel space efficiency.\u003c\/p\u003e\n\u003cp\u003eThe 3333 features easy DIP-switch configuration for over 1,000 factory-calibrated temperature ranges and robust terminal protection against over-voltage, polarity reversal, and short circuits. Thus, the PR 3333 delivers dependable, high-performance Pt100 temperature conversion for water\/wastewater, chemical, energy, and manufacturing applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy configuration via DIP switches.\u003c\/li\u003e\n\u003cli\u003eSelectable DIP settings for easy configuration of more than 1000 factory calibrated measurement ranges.\u003c\/li\u003e\n\u003cli\u003eThe narrow 6.1 mm housing allows up to 163 units per meter.\u003c\/li\u003e\n\u003cli\u003eUnits can mount side by side, horizontally, and vertically, without air gap on a standard DIN rail, even at 158˚F (70˚C) ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3333-Pt100-temperature-converter-pr-electronics-temp-converter-signal-conditioning-process-solutions-corp-psc-texas.jpg?v=1768940370\" alt=\"PR-3333-Pt100-temperature-converter-pr-electronics-temp-converter-signal-conditioning-process-solutions-corp-psc-texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"Default Title","offer_id":45878367682691,"sku":"3333","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-3333-Pt100-Temperature-Converter-PR-electronics-signal-converter-temp-process-solutions-corp-texas.jpg?v=1768940387","url":"https:\/\/www.psctexas.shop\/products\/pr-3333-pt100-temperature-converter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}