{"product_id":"pr-6335-2-wire-hart-transmitter","title":"PR 6335 2-wire HART Transmitter","description":"\u003cp\u003eThe PR 6335 2-wire HART Transmitter is a high-performance industrial \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature transmitter\u003c\/a\u003e for precise temperature and resistance \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003esignal conversion\u003c\/a\u003e in advanced process automation systems. The 6335 Series, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, supports RTD (Pt100-Pt1000, Ni100-Ni1000), thermocouple (TC), linear resistance, as well as mV inputs. Furthermore, this versatile transmitter converts sensor signals into a standardized 4-20 mA output with integrated \u003ca title=\"HART Protocol Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\"\u003eHART\u003c\/a\u003e communication for efficient monitoring and control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with Pt100-Pt1000, Ni100-Ni1000, as well as TC sensors. \u003c\/li\u003e\n\u003cli\u003eDifference or average temperature measurement of 2 resistance (RTD) or TC sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance variation to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of a bipolar mV signal to a standard 4-20 mA current signal.\u003c\/li\u003e\n\u003cli\u003eConnection of up to 15 channels to a digital 2-wire signal with HART communication.\u003c\/li\u003e\n\u003cli\u003eModels in the 6335 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e, galvanically \u003ca title=\"Signal Isolation Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\"\u003eisolated\u003c\/a\u003e, and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335A 2-wire HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335a\/\" target=\"_blank\"\u003ePR 6335A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6335D 2-wire Ex HART Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6335d\/\" target=\"_blank\"\u003ePR 6335D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 6335 2-wire HART Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 6335 offers HART 5 protocol support and galvanic isolation between input and output. Furthermore, the 6335 2-wire HART Transmitter delivers robust signal integrity and reliable data transmission even in electrically noisy industrial environments. This transmitter offers programmable response time (1-60s), sensor error detection compliance with \u003ca title=\"NAMUR Association\" href=\"https:\/\/www.namur.net\/en\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE89, and cable compensation for 2-, 3-, or 4-wire configurations. Thus, the PR 6335 Series ensures accurate measurements with minimal wiring impact. With better than 0.05% accuracy of the selected range and support for differential or average temperature measurement, the 6335 Series fits a broad range of industrial applications including manufacturing, energy, chemical processing, HVAC, and automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWithin a few seconds, users can program the PR 6335 Series to measure temperatures within all ranges defined by the norms.\u003c\/li\u003e\n\u003cli\u003eRTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.\u003c\/li\u003e\n\u003cli\u003eThe PR 6335 2-wire HART Transmitter provides the necessary failure data (SFF and PFDAVG) for SIL applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511.\u003c\/li\u003e\n\u003cli\u003eA limit can be programmed on the output signal.\u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data for safety reasons.\u003c\/li\u003e\n\u003cli\u003eSensor error detection according to the guidelines in NAMUR NE89.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eConfiguration and diagnostics are simple and use standard HART interfaces or the PR Loop Link communication tool. Thus, the PR 6335 2-wire HART Transmitter enables remote parameterization and real-time device insights for improving maintenance and uptime. With certification for installations in hazardous areas, this transmitter combines accuracy, connectivity, and durability for demanding industrial temperature measurement needs. \u003cmeta charset=\"utf-8\"\u003eInstallation is flexible, mountable vertically or horizontally on standard DIN rails with up to 84 channels per meter for high-density panel layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts vertically or horizontally on a DIN rail.\u003c\/li\u003e\n\u003cli\u003eUsing the 2-channel version, users can mount up to 84 channels per meter. \u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225929\" alt=\"PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-6335D-PR6335-2-wire-Ex-HART-Transmitter-industrial-temperature-transmitter-signal-isolator-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46470501695619,"sku":"6335A2A","price":514.0,"currency_code":"USD","in_stock":true},{"title":"6335A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46470501728387,"sku":"6335A2B","price":917.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 1-Channel","offer_id":46470501761155,"sku":"6335D2A","price":561.0,"currency_code":"USD","in_stock":true},{"title":"6335D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 2-Channel","offer_id":46470501793923,"sku":"6335D2B","price":1001.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6335-2-wire-HART-Transmitter-PR-electronics-6335A-signal-isolation-temperature-transmitter-rtd-thermocouple-Process-Solutions-Corp-PSC-Texas.jpg?v=1770225948","url":"https:\/\/www.psctexas.shop\/products\/pr-6335-2-wire-hart-transmitter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}