{"product_id":"pr-6337-2-wire-hart-temperature-transmitter","title":"PR 6337 2-wire HART Temperature Transmitter","description":"\u003cp\u003eThe PR 6337 2-wire HART Temperature Transmitter is a highly adaptable industrial \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\" title=\"Signal Conditioning Devices\"\u003esignal transmitter\u003c\/a\u003e for precise temperature and process measurement in advanced automation systems. This \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/temperature\" title=\"Temperature Transmitters\"\u003etemperature transmitter\u003c\/a\u003e is capable of supporting RTD, thermocouple (TC), linear resistance, and bipolar mV inputs. Furthermore, the 6337 Series, from \u003ca href=\"https:\/\/www.prelectronics.com\" title=\"PR electronics Signal Conditioning Devices\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, converts sensor signals into a standardized 4-20 mA output with integrated \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hart-protocol\" title=\"HART Protocol Instrumentation\"\u003eHART\u003c\/a\u003e communication (selectable HART 5 or HART 7), which enhances diagnostics, configuration, and remote device management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinearized temperature measurement with TC and RTD sensors, for example, Pt100 and Ni100.\u003c\/li\u003e\n\u003cli\u003eHART communication and 4-20 mA analog PV output for individual, difference, or average temperature measurement of up to two RTD or TC input sensors.\u003c\/li\u003e\n\u003cli\u003eConversion of linear resistance to a standard analog current signal, for example, from \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/valves\" title=\"Valve Instrumentation\"\u003evalves\u003c\/a\u003e or Ohmic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/level-sensors\" title=\"Level Instrumentation\"\u003elevel\u003c\/a\u003e sensors.\u003c\/li\u003e\n\u003cli\u003eAmplification of bipolar mV signals to standard 4-20 mA current signals.\u003c\/li\u003e\n\u003cli\u003eUp to 63 transmitters (HART 7) can connect in a multidrop communication setup.\u003c\/li\u003e\n\u003cli\u003eModels in the 6337 Series are \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\" title=\"Intrinsically Safe Instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca title=\"Hazardous Area Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\"\u003ehazardous areas\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6337A 2-wire HART Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6337a\/\" target=\"_blank\"\u003ePR 6337A\u003c\/a\u003e has certification for mounting in Zone 2 and 22 \/ Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 6337D 2-wire HART Ex Temperature Transmitter\" href=\"https:\/\/www.prelectronics.com\/products\/temperature-transmitters\/6300\/2-wire-hart-transmitter-6337d\/\" target=\"_blank\"\u003ePR 6337D\u003c\/a\u003e has certification for mounting in Zone 0, 1, 2, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003ePR 6337 2-wire HART Temperature Transmitter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eIdeal for industrial control, energy, and manufacturing applications, this transmitter reliably measures individual, differential, or averaged temperature values from up to two sensors. The HART 7 protocol offers long tag names, event logging with time stamps, burst mode, and flexible device variable mapping. Thus, the PR 6337 2-wire HART Temperature Transmitter enables smarter process monitoring and seamless integration with \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/automation-controllers-hmi-plc\" title=\"Automation Controllers\"\u003ePLCs\u003c\/a\u003e, DCS, and asset management systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHART protocol revision can change by user configuration to either HART 5 or HART 7 protocol.\u003c\/li\u003e\n\u003cli\u003eThe HART 7 protocol offers:\n\u003cul\u003e\n\u003cli\u003eLong Tag numbers of up to 32 characters.\u003c\/li\u003e\n\u003cli\u003eEnhanced Burst Mode and Event notification with time stamping.\u003c\/li\u003e\n\u003cli\u003eDevice variable and status mapping to any dynamic variable PV, SV, TV, or QV.\u003c\/li\u003e\n\u003cli\u003eProcess signal trend measurement with logs and summary data.\u003c\/li\u003e\n\u003cli\u003eAutomatic event notification with time stamps.\u003c\/li\u003e\n\u003cli\u003eCommand aggregation for higher communication efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe PR 6337 2-wire HART Temperature Transmitter provides the necessary failure data (SFF and PFD\u003csmall\u003eAVG\u003c\/small\u003e) for SIL applications as per \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508 \/ IEC 61511. \u003c\/li\u003e\n\u003cli\u003eContinuous check of vital storage data.\u003c\/li\u003e\n\u003cli\u003eMeeting the \u003ca href=\"https:\/\/www.namur.net\/en\" title=\"NAMUR Association\" rel=\"noopener\" target=\"_blank\"\u003eNAMUR\u003c\/a\u003e NE21 recommendations, the PR 6337 HART transmitter ensures top measurement performance in harsh EMC environments. \u003c\/li\u003e\n\u003cli\u003eIn addition, the PR 6337 meets NAMUR NE43 and NE89 recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eBuilt for demanding environments, the PR 6337 meets key industrial standards, including NAMUR NE21, NE43, and NE89 EMC recommendations. Furthermore, the 6337 Series is assessed for use in SIL safety applications, ensuring dependable measurement performance. DIN-rail mounting supports high channel density (up to 84 channels\/meter), and users can perform configuration via standard HART interfaces or the PR 5909 Loop Link tool. The 6337 Series offers better than 0.05% accuracy, programmable response times (1-60s), as well as robust signal integrity in harsh electrical environments. In addition, the PR 6337 delivers precise, reliable temperature measurement for advanced industrial automation and safety-critical systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mounting with up to 84 channels per meter.\u003c\/li\u003e\n\u003cli\u003eConfiguration via standard HART communication interfaces or by PR 5909 Loop Link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas.jpg?v=1770232311\" alt=\"PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-PR6337-6337A-6337D-intrinsically-safe-temperature-transmitter-HART-protocol-5-7-process-solutions-corp-PSC-Texas\" style=\"margin-top: 25px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"6337A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 1-Channel","offer_id":46471005208707,"sku":"6337A2A","price":514.0,"currency_code":"USD","in_stock":true},{"title":"6337A: General Purpose; Zone 2 and 22 \/ Class I; Div 2; Groups A B C D \/ 2-Channel","offer_id":46471005241475,"sku":"6337A2B","price":917.0,"currency_code":"USD","in_stock":true},{"title":"6337D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 1-Channel","offer_id":46471005274243,"sku":"6337D2A","price":618.0,"currency_code":"USD","in_stock":true},{"title":"6337D: Zone 0; 1; 2; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D \/ 2-Channel","offer_id":46471005307011,"sku":"6337D2B","price":1105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-6337-2-wire-HART-Temperature-Transmitter-PR-electronics-hart-protocol-temperature-measurement-Process-Solutions-Corp-PSC-Texas.jpg?v=1770233137","url":"https:\/\/www.psctexas.shop\/products\/pr-6337-2-wire-hart-temperature-transmitter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}