{"product_id":"pr-9116-universal-converter","title":"PR 9116 Universal Converter","description":"\u003cp\u003eThe PR 9116 Universal Converter is a high-performance \u003ca title=\"Signal Conditioning Devices\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-conditioning\"\u003esignal conditioning\u003c\/a\u003e device for industrial process control and automation. The 9116, from \u003ca title=\"PR electronics Signal Conditioning Devices\" href=\"https:\/\/www.prelectronics.com\" target=\"_blank\"\u003ePR electronics\u003c\/a\u003e, is ideal for converting and scaling a wide range of inputs including RTD, thermocouple (TC), ohm, potentiometer, mA, as well as V signals. Furthermore, this \u003ca title=\"Signal Converters\" href=\"https:\/\/www.psctexas.shop\/collections\/signal-converters\"\u003euniversal converter\u003c\/a\u003e delivers precise and reliable measurement conversion for \u003ca title=\"Temperature Transmitters\" href=\"https:\/\/www.psctexas.shop\/collections\/temperature\"\u003etemperature\u003c\/a\u003e, voltage, and resistance inputs. It also provides a stable \u003ca title=\"Power and Supply\" href=\"https:\/\/www.psctexas.shop\/collections\/power-and-supply\"\u003esupply\u003c\/a\u003e for 2-wire transmitters with active or passive mA outputs and integrated relay outputs for flexible control applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration and monitoring by way of detachable display front (\u003ca title=\"PR 4500 Series Programming Interfaces\" href=\"https:\/\/www.psctexas.shop\/collections\/programming-interfaces\"\u003ePR 4500\u003c\/a\u003e Series) for process calibration in addition to signal and relay simulation. \u003c\/li\u003e\n\u003cli\u003eAdvanced relay configuration, for example, setpoint, window, delay, sensor error indication, and power monitoring.\u003c\/li\u003e\n\u003cli\u003eCopying of the configuration from one device to others of the same type via the display front.\u003c\/li\u003e\n\u003cli\u003eTC inputs with internal CJC or external CJC for higher accuracy.\u003c\/li\u003e\n\u003cli\u003eActive \/ passive mA output via the same two terminals.\u003c\/li\u003e\n\u003cli\u003eModels in the 9116 Series are \u003ca title=\"Intrinsically Safe Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/intrinsically-safe-instrumentation\"\u003eintrinsically safe\u003c\/a\u003e and feature various certifications for use in \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/hazardous-area-instrumentation\" title=\"Hazardous Area Instrumentation\"\u003ehazardous areas\u003c\/a\u003e as well as for \u003ca title=\"Marine Certified Instrumentation\" href=\"https:\/\/www.psctexas.shop\/collections\/marine-certified\"\u003emarine applications\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eModel \u003ca title=\"PR electronics 9116A Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/multifunctional-devices\/9100\/universal-converter-9116a\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116A\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in safe areas and can also mount in Zone 2 \/ Class I, Div 2, Groups A, B, C, D.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eModel \u003ca title=\"PR electronics 9116B Universal Converter\" href=\"https:\/\/www.prelectronics.com\/products\/i-s-interfaces\/9100\/universal-converter-9116b\/\" rel=\"noopener\" target=\"_blank\"\u003ePR 9116B\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in Zone 2 \/ Class I, Div 2; it can also receive signals from Zone 0, 1, 2, 20, 21, 22, M1 \/ Class I, II, III, Div 1, Groups A, B, C, D, E, F, G.\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduced Uo Ex data \u0026lt; 8.3 V for active input signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePR 9116 Universal Converter from PR electronics\u003c\/h2\u003e\n\u003cp\u003eThe PR 9116 features robust galvanic \u003ca href=\"https:\/\/www.psctexas.shop\/collections\/signal-isolation-devices\" title=\"Signal Isolation Devices\"\u003eisolation\u003c\/a\u003e between input, output, and power as well as compact DIN-rail mounting compatibility. As a result, the PR 9116 Universal Converter is ideal for reliable signal processing in automation, energy, chemical, oil \u0026amp; gas, and manufacturing systems. Built for durability and accuracy, this versatile converter enhances control system performance while minimizing downtime and maintenance needs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion and scaling of temperature, voltage, potentiometer, as well as linear resistance signals.\u003c\/li\u003e\n\u003cli\u003ePower supply and signal isolator for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMonitoring of error events and cable breakage via the individual status relay and\/or a collective electronic signal via the power rail.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Series has been designed, developed, and certified for use in SIL 2 applications according to the requirements of \u003ca href=\"https:\/\/www.iec.ch\/homepage\" title=\"International Electrotechnical Commission\" rel=\"noopener\" target=\"_blank\"\u003eIEC\u003c\/a\u003e 61508.\u003c\/li\u003e\n\u003cli\u003eFailure rates for the 9116 Series correspond to Performance Level \"d\" according to ISO-13849.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eEasy Mounting, Installation, and Programming\u003c\/h2\u003e\n\u003cp\u003eFeaturing certification for SIL 2 safety integrity, this universal converter meets stringent safety standards necessary in modern industrial environments. Easy configuration and monitoring are available via a detachable front display, thus allowing process calibration, signal simulation, and advanced relay logic setup.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 green and 1 red front LED indicate operation status and malfunction.\u003c\/li\u003e\n\u003cli\u003e1 yellow LED indicates relay status.\u003c\/li\u003e\n\u003cli\u003e2.6 kVAC galvanic isolation between input, output, and supply.\u003c\/li\u003e\n\u003cli\u003eThe PR 9116 Universal Converter can mount vertically or horizontally without distance between neighboring units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutio.jpg?v=1770654546\" alt=\"PR-9116-Universal-Converter-PR-electronics-9116A-9116B-PR9116-Temperature-Transmitter-Signal-Converter-Voltage-Resistance-Conversion-Hazardous-Area-Signal-Conditioning-Process-Solutions-Corp-PSC-Texas\" style=\"margin-top: 025px; float: none;\"\u003e\u003c\/div\u003e","brand":"PR electronics","offers":[{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483617411,"sku":"9116A1","price":543.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483650179,"sku":"9116A1-U9","price":554.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483682947,"sku":"9116A2","price":550.0,"currency_code":"USD","in_stock":true},{"title":"9116A: Safe Area; Zone 2 \/ Class I; Div 2; Groups A B C D \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483715715,"sku":"9116A2-U9","price":557.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ None - Standard","offer_id":46575483748483,"sku":"9116B1","price":570.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 1: Uo 28 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483781251,"sku":"9116B1-U9","price":579.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ None - Standard","offer_id":46575483814019,"sku":"9116B2","price":577.0,"currency_code":"USD","in_stock":true},{"title":"9116B: Zone 0; 1; 2; 20; 21; 22; M1 \/ Class I; II; III; Div 1; Groups A B C D E F G \/ 2: Uo 21.4 VDC \/ -U9: U9\/UL913 Approval","offer_id":46575483846787,"sku":"9116B2-U9","price":583.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/1955\/0595\/files\/PR-9116-Universal-Converter-PR-electronics-9116A-Signal-Converter-Universal-Transmitter-Temperature-Voltage-Linear-Resistance-Process-Solutions-Texas.jpg?v=1770655699","url":"https:\/\/www.psctexas.shop\/products\/pr-9116-universal-converter","provider":"Process Solutions Corp.","version":"1.0","type":"link"}