The PR 5437 HART 7 Temperature Transmitter is a high-performance industrial temperature transmitter for precision temperature measurement and reliable signal conversion in process automation systems. The 5437 Series, from PR electronics, is perfect for use with a wide range of RTD (resistance temperature detector), thermocouple (TC), potentiometer, bipolar mV, and linear resistance inputs. This HART 7 temperature transmitter delivers accurate 4-20 mA analog outputs directly to PLCs, DCS, and SCADA systems. Its advanced HART 7 communication protocol enables remote configuration, real-time diagnostics, and enhances asset management for smarter industrial control operations.
- Temperature measurement of a wide range of TC and RTD types.
- Conversion of wide span linear resistance and potentiometer inputs.
- Conversion of bipolar mV signals to 4-20 mA.
- Integration into asset management schemes.
- Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.
- Models in the 5437 Series are galvanically isolated as well as intrinsically safe and feature multiple, different certifications for use in hazardous areas, and is suitable for use in marine applications.
- Model PR 5437A has certification for mounting in Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D.
- Model PR 5437B has certification for mounting in Zone 0, 1, 2, 21, 22, M1.
- Model PR 5437D has certification for mounting in Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D.
PR 5437 HART 7 Temperature Transmitter from PR electronics
Excelling in the most demanding industrial environments, the PR 5437 HART 7 Temperature Transmitter features true dual-input capability with sensor redundancy and drift detection. As a result, the 5437 maximizes uptime and simplifies maintenance planning. The PR 5437 Series features total measurement accuracy from as low as 0.014%, wide operating ambient temperature range -58 to 185˚F (-50 to 85˚C), and robust 2.5 kVAC galvanic isolation. Furthermore, this HART 7 temperature transmitter ensures dependable performance and signal integrity even under electrical noise and harsh conditions.
- True dual input transmitter.
- High density 7-terminal design accepts the widest range of dual input combinations.
- Sensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, thus maintaining uptime.
- Sensor drift detection - alerts when sensor differential exceeds user-defined limits for maintenance optimization.
- Dynamic variable mapping for process data in addition to the primary variable, for example, dual input features such as average, differential, and minimum/maximum tracking.
- Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
- Extensive sensor matching including Callendar Van Dusen as well as custom linearization.
- Programmable input limits and runtime metering ensure maximum process traceability and also provides sensor out of range protection.
-
IEC 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
- Meets NAMUR NE21, NE43, NE44, NE89, NE95, NE130 and NE107 compliant diagnostics information.
- Model 5437xxSx provides failure rates that correspond to Performance Level "d" according to ISO-13849.
Easy Mounting, Installation, and Programming
The 2-wire loop-power design supports flexible deployment in existing infrastructures with minimal wiring. Furthermore, comprehensive diagnostics and compliance with industry standards (including SIL 2/3 functional safety) make the PR 5437 Series ideal for critical process control applications. Whether measuring temperature in manufacturing, energy, or chemical processing, the PR 5437 HART 7 Temperature Transmitter provides precise, HART-enabled temperature measurement that improves process reliability and overall operational efficiency.
- For DIN form B sensor head mounting.
- Configuration via standard HART communication interfaces or by PR 5909 Loop Link.

Models of the PR 5437 HART 7 Temperature Transmitter
| Model ID | Mounting Location | Inputs | Additional Approvals |
|---|---|---|---|
| PR 5437A1-- | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 1: Single Input - 4 Terminals | – |
| PR 5437A1S- | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 1: Single Input - 4 Terminals | SIL |
| PR 5437A1-M | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 1: Single Input - 4 Terminals | Marine |
| PR 5437A1SM | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 1: Single Input - 4 Terminals | SIL and Marine |
| PR 5437A2-- | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 2: Dual Input - 7 Terminals | – |
| PR 5437A2S- | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 2: Dual Input - 7 Terminals | SIL |
| PR 5437A2-M | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 2: Dual Input - 7 Terminals | Marine |
| PR 5437A2SM | Zone 2 and 22 / Class I, Div 2, Groups A, B, C, D | 2: Dual Input - 7 Terminals | SIL and Marine |
| PR 5437B1-- | Zone 0, 1, 2, 21, 22, M1 | 1: Single Input - 4 Terminals | – |
| PR 5437B1S- | Zone 0, 1, 2, 21, 22, M1 | 1: Single Input - 4 Terminals | SIL |
| PR 5437B1-M | Zone 0, 1, 2, 21, 22, M1 | 1: Single Input - 4 Terminals | Marine |
| PR 5437B1SM | Zone 0, 1, 2, 21, 22, M1 | 1: Single Input - 4 Terminals | SIL and Marine |
| PR 5437B2-- | Zone 0, 1, 2, 21, 22, M1 | 2: Dual Input - 7 Terminals | – |
| PR 5437B2S- | Zone 0, 1, 2, 21, 22, M1 | 2: Dual Input - 7 Terminals | SIL |
| PR 5437B2-M | Zone 0, 1, 2, 21, 22, M1 | 2: Dual Input - 7 Terminals | Marine |
| PR 5437B2SM | Zone 0, 1, 2, 21, 22, M1 | 2: Dual Input - 7 Terminals | SIL and Marine |
| PR 5437D1-- | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
1: Single Input - 4 Terminals | – |
| PR 5437D1S- | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
1: Single Input - 4 Terminals | SIL |
| PR 5437D1-M | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
1: Single Input - 4 Terminals | Marine |
| PR 5437D1SM | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
1: Single Input - 4 Terminals | SIL and Marine |
| PR 5437D2-- | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
2: Dual Input - 7 Terminals | – |
| PR 5437D2S- | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
2: Dual Input - 7 Terminals | SIL |
| PR 5437D2-M | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
2: Dual Input - 7 Terminals | Marine |
| PR 5437D2SM | Zone 0, 1, 2, 21, 22, M1 / Class I, Div 1, Groups A, B, C, D |
2: Dual Input - 7 Terminals | SIL and Marine |
Product Documents
Data Sheets
Certifications
- DNV Marine Certificate - PR 5437 Series
- SIL Certificate - PR 5437 Series
- ATEX Certificate - PR 5437A
- CSA Certificate - PR 5437A
- FM Certificate - PR 5437A
- IECEx Certificate - PR 5437A
- ATEX Certificate - PR 5437B
- ATEX Certificate - PR 5437D
- CSA Certificate - PR 5437D
- FM Certificate - PR 5437D
- IECEx Certificate - PR 5437D
Other Details not Available